<?xml version="1.0" encoding="utf-8"?>
<ifcXML xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.buildingsmart-tech.org/ifc/IFC4x1/final" xsi:schemaLocation="http://standards.buildingsmart.org/IFC/RELEASE/IFC4_1/FINAL/XML/IFC4x1.xsd">
	<header />
	<IfcProjectLibrary GlobalId="2OqsW47Dz0LgTmf4DAn1f4" Name="IFC Templates">
		<IfcRelDeclares GlobalId="3RyLNYXkX479wspBr_nf6n" Name="SimpleProperties">
			<RelatedDefinitions>
				<IfcSimplePropertyTemplate id="AbnormalBerthingFactor_3YCoiqGvvD0AA61M_rVW_n" GlobalId="3YCoiqGvvD0AA61M_rVW_n" Name="AbnormalBerthingFactor" Description="Risk assessed safety factor" TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="AboveDeckProjectedWindEnd_2t7V67QC51PRcOCLDdpQcG" GlobalId="2t7V67QC51PRcOCLDdpQcG" Name="AboveDeckProjectedWindEnd" Description="End on projected windage area above the main deck" TemplateType="p_singlevalue" PrimaryMeasureType="IfcAreaMeasure" />
				<IfcSimplePropertyTemplate id="AboveDeckProjectedWindSide_27Fti2ntX0dgiVBd5Ek6wY" GlobalId="27Fti2ntX0dgiVBd5Ek6wY" Name="AboveDeckProjectedWindSide" Description="Side on projected windage area above the main deck" TemplateType="p_singlevalue" PrimaryMeasureType="IfcAreaMeasure" />
				<IfcSimplePropertyTemplate id="AboveGround_29uzs0qSKHuO00025QrE$V" GlobalId="29uzs0qSKHuO00025QrE$V" Name="AboveGround" Description="Indication whether this building storey is fully above ground (TRUE), or below ground (FALSE), or partially above and below ground (UNKNOWN) - as in sloped terrain." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLogical" />
				<IfcSimplePropertyTemplate id="AcceptanceDate_12dHQ2H3D5Vw6e1UM1sbnF" GlobalId="12dHQ2H3D5Vw6e1UM1sbnF" Name="AcceptanceDate" Description="Date on which the element is accepted by the manager or administrator." TemplateType="p_singlevalue" PrimaryMeasureType="IfcDate" />
				<IfcSimplePropertyTemplate id="AccessCoverLoadRating_0ocJc0qTGHuO00025QrE$V" GlobalId="0ocJc0qTGHuO00025QrE$V" Name="AccessCoverLoadRating" Description="The load rating of the access cover (which may be a value or an alphanumerically defined class rating)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="AccessCoverLoadRating_28kQq0qTCHuO00025QrE$V" GlobalId="28kQq0qTCHuO00025QrE$V" Name="AccessCoverLoadRating" Description="The load rating of the access cover (which may be a value or an alphanumerically defined class rating)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="AccessCoverLoadRating_3KR5Q0qTCHuO00025QrE$V" GlobalId="3KR5Q0qTCHuO00025QrE$V" Name="AccessCoverLoadRating" Description="The load rating of the access cover (which may be a value or an alphanumerically defined class rating)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="AccessCoverMaterial_0ZieS0qTGHuO00025QrE$V" GlobalId="0ZieS0qTGHuO00025QrE$V" Name="AccessCoverMaterial" Description="The material from which the access cover to the chamber is constructed.
NOTE: It is assumed that chamber walls will be constructed of a single material." TemplateType="p_referencevalue" PrimaryMeasureType="IfcMaterialDefinition" />
				<IfcSimplePropertyTemplate id="AccessLengthOrRadius_0chNU0qTGHuO00025QrE$V" GlobalId="0chNU0qTGHuO00025QrE$V" Name="AccessLengthOrRadius" Description="The length of the chamber access cover or, where the plan shape of the cover is circular, the radius." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="AccessLengthOrRadius_30mF00qTCHuO00025QrE$V" GlobalId="30mF00qTCHuO00025QrE$V" Name="AccessLengthOrRadius" Description="The length of the chamber access cover or, where the plan shape of the cover is circular, the radius." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="AccessType_3Im8G0qWyHuO00025QrE$V" GlobalId="3Im8G0qWyHuO00025QrE$V" Name="AccessType" Description="Defines the types of access (or cover) to a tank that may be specified.

Note that covers are generally specified for rectangular tanks. For cylindrical tanks, access will normally be via a manhole." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_TankAccessType">
						<EnumerationValues>
							<IfcLabel-wrapper>NONE</IfcLabel-wrapper>
							<IfcLabel-wrapper>LOOSECOVER</IfcLabel-wrapper>
							<IfcLabel-wrapper>MANHOLE</IfcLabel-wrapper>
							<IfcLabel-wrapper>SECUREDCOVER</IfcLabel-wrapper>
							<IfcLabel-wrapper>SECUREDCOVERWITHMANHOLE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="AccessWidth_0ierY0qTGHuO00025QrE$V" GlobalId="0ierY0qTGHuO00025QrE$V" Name="AccessWidth" Description="The width of the chamber access cover where the plan shape of the cover is not circular." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="AccessWidth_367Zg0qTCHuO00025QrE$V" GlobalId="367Zg0qTCHuO00025QrE$V" Name="AccessWidth" Description="The width of the chamber access cover where the plan shape of the cover is not circular." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="AccidentResponse_1CQaLudWX1ogX8LOMOUW_1" GlobalId="1CQaLudWX1ogX8LOMOUW_1" Name="AccidentResponse" Description="Accident response chosen for the asset" TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_AccidentResponse">
						<EnumerationValues>
							<IfcLabel-wrapper>EMERGENCYPROCEDURE</IfcLabel-wrapper>
							<IfcLabel-wrapper>URGENTPROCEDURE</IfcLabel-wrapper>
							<IfcLabel-wrapper>EMERGENCYINSPECTION</IfcLabel-wrapper>
							<IfcLabel-wrapper>URGENTINSPECTION</IfcLabel-wrapper>
							<IfcLabel-wrapper>REACTIVE</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="AccuracyClass_32YEer4tP9EB633g5FK49p" GlobalId="32YEer4tP9EB633g5FK49p" Name="AccuracyClass" Description="A designation assigned to an instrument transformer the current (or voltage) error and phase displacement of which remain within specified limits under prescribed conditions of use (IEC 321-01-24)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="AccuracyGrade_3y6bNc8F56Hexr9v$dk$2L" GlobalId="3y6bNc8F56Hexr9v$dk$2L" Name="AccuracyGrade" Description="The grade of accuracy." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="AccuracyOfFireSensor_0cUQ00qWKHuO00025QrE$V" GlobalId="0cUQ00qWKHuO00025QrE$V" Name="AccuracyOfFireSensor" Description="The accuracy of the sensor." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="AccuracyQualityExpected_1ynE_0qS4HuO00025QrE$V" GlobalId="1ynE_0qS4HuO00025QrE$V" Name="AccuracyQualityExpected" Description="A measure of the accuracy quality of survey points as expected expressed in percentage terms." TemplateType="p_singlevalue" PrimaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="AccuracyQualityObtained_1spmw0qS4HuO00025QrE$V" GlobalId="1spmw0qS4HuO00025QrE$V" Name="AccuracyQualityObtained" Description="A measure of the accuracy quality of survey points as obtained expressed in percentage terms." TemplateType="p_singlevalue" PrimaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="AcidityConcentration_0o3Po0qUuHuO00025QrE$V" GlobalId="0o3Po0qUuHuO00025QrE$V" Name="AcidityConcentration" Description="Maximum CaCO3 equivalent that would neutralize the acid." TemplateType="p_singlevalue" PrimaryMeasureType="IfcIonConcentrationMeasure" />
				<IfcSimplePropertyTemplate id="Acknowledge_3v2mC0qS0HuO00025QrE$V" GlobalId="3v2mC0qS0HuO00025QrE$V" Name="Acknowledge" Description="Indicates acknowledgement status where False indicates acknowlegement is required and outstanding, True indicates condition has been acknowedged, and Unknown indicates no acknowledgement is required. Upon resetting the condition, then acknowledgement reverts to Unknown." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcLogical" />
				<IfcSimplePropertyTemplate id="AcousticRating_0aywm0qVGHuO00025QrE$V" GlobalId="0aywm0qVGHuO00025QrE$V" Name="AcousticRating" Description="Acoustic rating for this object.
It is provided according to the national building code. It indicates the sound transmission resistance of this object by an index ratio (instead of providing full sound absorption values)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="AcousticRating_0D9YC0qWWHuO00025QrE$V" GlobalId="0D9YC0qWWHuO00025QrE$V" Name="AcousticRating" Description="Acoustic rating for this object.
It is provided according to the national building code. It indicates the sound transmission resistance of this object by an index ratio (instead of providing full sound absorption values)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="AcousticRating_0kQnq0qT0HuO00025QrE$V" GlobalId="0kQnq0qT0HuO00025QrE$V" Name="AcousticRating" Description="Acoustic rating for this object.
It is provided according to the national building code. It indicates the sound transmission resistance of this object by an index ratio (instead of providing full sound absorption values)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="AcousticRating_13UqKWrSfDIwPMac2f7fRy" GlobalId="13UqKWrSfDIwPMac2f7fRy" Name="AcousticRating" Description="Acoustic rating for this object.
It is provided according to the national building code. It indicates the sound transmission resistance of this object by an index ratio (instead of providing full sound absorption values).

Requirement for the element filling the opening." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="AcousticRating_2jnHI0qW4HuO00025QrE$V" GlobalId="2jnHI0qW4HuO00025QrE$V" Name="AcousticRating" Description="Acoustic rating for this object.
It is provided according to the national building code. It indicates the sound transmission resistance of this object by an index ratio (instead of providing full sound absorption values)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="AcousticRating_2LGWE0qTiHuO00025QrE$V" GlobalId="2LGWE0qTiHuO00025QrE$V" Name="AcousticRating" Description="Acoustic rating for this object.
It is provided according to the national building code. It indicates the sound transmission resistance of this object by an index ratio (instead of providing full sound absorption values)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="AcousticRating_2vS0M0qXWHuO00025QrE$V" GlobalId="2vS0M0qXWHuO00025QrE$V" Name="AcousticRating" Description="Acoustic rating for this object.
It is provided according to the national building code. It indicates the sound transmission resistance of this object by an index ratio (instead of providing full sound absorption values)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="AcousticRating_31UdO0qXKHuO00025QrE$V" GlobalId="31UdO0qXKHuO00025QrE$V" Name="AcousticRating" Description="Acoustic rating for this object.
It is provided according to the national building code. It indicates the sound transmission resistance of this object by an index ratio (instead of providing full sound absorption values)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="AcquisitionDate_1BhUI0qUmHuO00025QrE$V" GlobalId="1BhUI0qUmHuO00025QrE$V" Name="AcquisitionDate" Description="The date that the manufactured item was purchased." TemplateType="p_singlevalue" PrimaryMeasureType="IfcDate" />
				<IfcSimplePropertyTemplate id="AcquisitionMethod_1Zl3w0qS4HuO00025QrE$V" GlobalId="1Zl3w0qS4HuO00025QrE$V" Name="AcquisitionMethod" Description="The means by which survey data was acquired." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_AcquisitionMethod">
						<EnumerationValues>
							<IfcLabel-wrapper>GPS</IfcLabel-wrapper>
							<IfcLabel-wrapper>LASERSCAN_AIRBORNE</IfcLabel-wrapper>
							<IfcLabel-wrapper>LASERSCAN_GROUND</IfcLabel-wrapper>
							<IfcLabel-wrapper>SONAR</IfcLabel-wrapper>
							<IfcLabel-wrapper>THEODOLITE</IfcLabel-wrapper>
							<IfcLabel-wrapper>USERDEFINED</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ACResistance_2$dT1WHiH7Ge2PeqXa73Sp" GlobalId="2$dT1WHiH7Ge2PeqXa73Sp" Name="ACResistance" Description="The resistance under AC." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricResistanceMeasure" />
				<IfcSimplePropertyTemplate id="ActionBarMovementLength_3g9eB0$QrCGgwW7XmrxaeO" GlobalId="3g9eB0$QrCGgwW7XmrxaeO" Name="ActionBarMovementLength" Description="The movement of the bar that pulls the point of a turnout." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="Activation_0nlTC0qUSHuO00025QrE$V" GlobalId="0nlTC0qUSHuO00025QrE$V" Name="Activation" Description="Identifies the predefined methods of sprinkler activation from which that required may be set." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_SprinklerActivation">
						<EnumerationValues>
							<IfcLabel-wrapper>BULB</IfcLabel-wrapper>
							<IfcLabel-wrapper>FUSIBLESOLDER</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ActivationTemperature_17ovE0qUSHuO00025QrE$V" GlobalId="17ovE0qUSHuO00025QrE$V" Name="ActivationTemperature" Description="The temperature at which the object is designed to activate." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="ActorCategory_1uL4DgMFDB2hgBJy6VL8l2" GlobalId="1uL4DgMFDB2hgBJy6VL8l2" Name="ActorCategory" Description="Designation of the category into which the actors in the population belong." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ActualCompletion_00qAI0qSqHuO00025QrE$V" GlobalId="00qAI0qSqHuO00025QrE$V" Name="ActualCompletion" Description="The actual completion percentage of the allocation." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="ActualCost_3v4G00qSmHuO00025QrE$V" GlobalId="3v4G00qSmHuO00025QrE$V" Name="ActualCost" Description="The actual cost on behalf of the resource allocation." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcMonetaryMeasure" />
				<IfcSimplePropertyTemplate id="ActualErectionDate_1oS1a0qVGHuO00025QrE$V" GlobalId="1oS1a0qVGHuO00025QrE$V" Name="ActualErectionDate" Description="Date erected." TemplateType="p_singlevalue" PrimaryMeasureType="IfcDateTime" />
				<IfcSimplePropertyTemplate id="ActualProductionDate_1jgsK0qVGHuO00025QrE$V" GlobalId="1jgsK0qVGHuO00025QrE$V" Name="ActualProductionDate" Description="Production date (stripped from form)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcDateTime" />
				<IfcSimplePropertyTemplate id="ActualWorkTime_3nKLk0qSmHuO00025QrE$V" GlobalId="3nKLk0qSmHuO00025QrE$V" Name="ActualWorkTime" Description="The actual work on behalf of the resource allocation." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcDuration" />
				<IfcSimplePropertyTemplate id="ActuationType_2yazC0qT4HuO00025QrE$V" GlobalId="2yazC0qT4HuO00025QrE$V" Name="ActuationType" Description="Enumeration that identifies the different types of dampers." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" id="i52" Name="PEnum_FireDamperActuationType">
						<EnumerationValues>
							<IfcLabel-wrapper>GRAVITY</IfcLabel-wrapper>
							<IfcLabel-wrapper>SPRING</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ActuationType_3jT0W0qT4HuO00025QrE$V" GlobalId="3jT0W0qT4HuO00025QrE$V" Name="ActuationType" Description="Enumeration that identifies the different types of dampers." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i52" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ActuatorApplication_08WRpjWCr7ePTPO7WG0_dT" GlobalId="08WRpjWCr7ePTPO7WG0_dT" Name="ActuatorApplication" Description="Indicates application of actuator." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ActuatorApplication">
						<EnumerationValues>
							<IfcLabel-wrapper>ENTRYEXITDEVICE</IfcLabel-wrapper>
							<IfcLabel-wrapper>FIRESMOKEDAMPERACTUATOR</IfcLabel-wrapper>
							<IfcLabel-wrapper>DAMPERACTUATOR</IfcLabel-wrapper>
							<IfcLabel-wrapper>VALVEPOSITIONER</IfcLabel-wrapper>
							<IfcLabel-wrapper>LAMPACTUATOR</IfcLabel-wrapper>
							<IfcLabel-wrapper>SUNBLINDACTUATOR</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ActuatorInputPower_1O$wg0qRqHuO00025QrE$V" GlobalId="1O$wg0qRqHuO00025QrE$V" Name="ActuatorInputPower" Description="Maximum input power requirement." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="ActuatorStatus_31OqXYkZzE68AGS6v3SXvr" GlobalId="31OqXYkZzE68AGS6v3SXvr" Name="ActuatorStatus" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" id="i58" Name="PEnum_ElementStatus">
						<EnumerationValues>
							<IfcLabel-wrapper>NEW</IfcLabel-wrapper>
							<IfcLabel-wrapper>EXISTING</IfcLabel-wrapper>
							<IfcLabel-wrapper>DEMOLISH</IfcLabel-wrapper>
							<IfcLabel-wrapper>TEMPORARY</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="AddedMassCoefficientMethod_32KBtk9g1DVge506I8DxMK" GlobalId="32KBtk9g1DVge506I8DxMK" Name="AddedMassCoefficientMethod" Description="Method used to determine the Added Mass Coefficient used for design" TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_AddedMassCoefficientMethod">
						<EnumerationValues>
							<IfcLabel-wrapper>PIANC</IfcLabel-wrapper>
							<IfcLabel-wrapper>SHIGERU_UEDA</IfcLabel-wrapper>
							<IfcLabel-wrapper>VASCO_COSTA</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="AdditionalProcessing_0GPWZ5EWD53Rg3vsFDWGkS" GlobalId="0GPWZ5EWD53Rg3vsFDWGkS" Name="AdditionalProcessing" Description="Any additional or special processing requirements on the associated cargo." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_AdditionalProcessing">
						<EnumerationValues>
							<IfcLabel-wrapper>NONE</IfcLabel-wrapper>
							<IfcLabel-wrapper>INSPECTION</IfcLabel-wrapper>
							<IfcLabel-wrapper>TARIFFS</IfcLabel-wrapper>
							<IfcLabel-wrapper>ISOLATION</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Addressablility_0re2G0qUmHuO00025QrE$V" GlobalId="0re2G0qUmHuO00025QrE$V" Name="Addressablility" Description="The type of addressability." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_AddressabilityType">
						<EnumerationValues>
							<IfcLabel-wrapper>IMPLEMENTED</IfcLabel-wrapper>
							<IfcLabel-wrapper>UPGRADEABLETO</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTIMPLEMENTED</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="AddressLines_0AokQv7wrDmAJlBklOK2nm" GlobalId="0AokQv7wrDmAJlBklOK2nm" Name="AddressLines" Description="The postal address.

&gt; NOTE&amp;nbsp; A postal address may occupy several lines (or elements) when recorded. It is expected that normal usage will incorporate relevant elements of the following address concepts: A location within a building (e.g. 3rd Floor) Building name (e.g. Interoperability House) Street number (e.g. 6400) Street name (e.g. Alliance Boulevard). Typical content of address lines may vary in different countries." TemplateType="p_listvalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="AdjustmentDesignation_34Q6q0qViHuO00025QrE$V" GlobalId="34Q6q0qViHuO00025QrE$V" Name="AdjustmentDesignation" Description="The desgnation on the device for the adjustment." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="AdjustmentDesignation_3fzNQ0qViHuO00025QrE$V" GlobalId="3fzNQ0qViHuO00025QrE$V" Name="AdjustmentDesignation" Description="The desgnation on the device for the adjustment." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="AdjustmentValueType_2ePCk0qViHuO00025QrE$V" GlobalId="2ePCk0qViHuO00025QrE$V" Name="AdjustmentValueType" Description="The type of adjustment value that is applied through the property set. This determines the properties that should be asserted (see below)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" id="i69" Name="PEnum_AdjustmentValueType">
						<EnumerationValues>
							<IfcLabel-wrapper>RANGE</IfcLabel-wrapper>
							<IfcLabel-wrapper>LIST</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="AdjustmentValueType_3FkvY0qViHuO00025QrE$V" GlobalId="3FkvY0qViHuO00025QrE$V" Name="AdjustmentValueType" Description="The type of adjustment value that is applied through the property set. This determines the properties that should be asserted (see below)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i69" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="AdmixturesDescription_3tLpI0qUmHuO00025QrE$V" GlobalId="3tLpI0qUmHuO00025QrE$V" Name="AdmixturesDescription" Description="Description of the admixtures added to the concrete mix." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="AgreementDate_1RCog0qVWHuO00025QrE$V" GlobalId="1RCog0qVWHuO00025QrE$V" Name="AgreementDate" Description="The date on which the version of the agreement became applicable." TemplateType="p_singlevalue" PrimaryMeasureType="IfcDate" />
				<IfcSimplePropertyTemplate id="AgreementType_0i7Ba0qVWHuO00025QrE$V" GlobalId="0i7Ba0qVWHuO00025QrE$V" Name="AgreementType" Description="Identifies the predefined types of property agreement from which the type required may be set." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_PropertyAgreementType">
						<EnumerationValues>
							<IfcLabel-wrapper>ASSIGNMENT</IfcLabel-wrapper>
							<IfcLabel-wrapper>LEASE</IfcLabel-wrapper>
							<IfcLabel-wrapper>TENANT</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="AgreementVersion_1GU9M0qVWHuO00025QrE$V" GlobalId="1GU9M0qVWHuO00025QrE$V" Name="AgreementVersion" Description="The version number of the agreement that is identified." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="AirConditioning_2VoC40qWmHuO00025QrE$V" GlobalId="2VoC40qWmHuO00025QrE$V" Name="AirConditioning" Description="Indication whether this space requires air conditioning provided (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="AirConditioningCentral_2blg80qWmHuO00025QrE$V" GlobalId="2blg80qWmHuO00025QrE$V" Name="AirConditioningCentral" Description="Indication whether the space requires a central air conditioning provided (TRUE) or not (FALSE).
It should only be given, if the property &quot;AirConditioning&quot; is set to TRUE." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="AirDiffusionPerformanceIndex_3TwyE0qRyHuO00025QrE$V" GlobalId="3TwyE0qRyHuO00025QrE$V" Name="AirDiffusionPerformanceIndex" Description="The Air Diffusion Performance Index (ADPI) is used for cooling mode conditions. If several measurements of air velocity and air temperature are made throughout the occupied zone of a space, the ADPI is the percentage of locations where measurements were taken that meet the specifications for effective draft temperature and air velocity." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="AirExchangeRate_2asK20qWiHuO00025QrE$V" GlobalId="2asK20qWiHuO00025QrE$V" Name="AirExchangeRate" Description="Loads from the air exchange rate." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="AirExchangeRateTimeHistory_0BzlK0qWmHuO00025QrE$V" GlobalId="0BzlK0qWmHuO00025QrE$V" Name="AirExchangeRateTimeHistory" Description="Loads from the air exchange rate." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="AirFlowConfiguration_1yVo40qSuHuO00025QrE$V" GlobalId="1yVo40qSuHuO00025QrE$V" Name="AirFlowConfiguration" Description="Air flow configuration type of cooled beam." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_CooledBeamActiveAirFlowConfigurationType">
						<EnumerationValues>
							<IfcLabel-wrapper>BIDIRECTIONAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNIDIRECTIONALRIGHT</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNIDIRECTIONALLEFT</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="AirFlowCurve_3XzvE1K1L4qhIMCR0uz5em" GlobalId="3XzvE1K1L4qhIMCR0uz5em" Name="AirFlowCurve" Description="" TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="AirFlowLeakage_3xBug0qTqHuO00025QrE$V" GlobalId="3xBug0qTqHuO00025QrE$V" Name="AirFlowLeakage" Description="Volumetric leakage flow rate." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="AirFlowRate_1iPq60qSuHuO00025QrE$V" GlobalId="1iPq60qSuHuO00025QrE$V" Name="AirFlowRate" Description="Air flow rate." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="AirFlowRate_29tKZHinXF9Pd1BmREa4Pc" GlobalId="29tKZHinXF9Pd1BmREa4Pc" Name="AirFlowRate" Description="Air flow rate.

The actual airflow rate as designed." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="AirFlowRate_33RXO0qT0HuO00025QrE$V" GlobalId="33RXO0qT0HuO00025QrE$V" Name="AirFlowRate" Description="Air flow rate." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="AirFlowRate_3A0ue0qTuHuO00025QrE$V" GlobalId="3A0ue0qTuHuO00025QrE$V" Name="AirFlowRate" Description="Air flow rate.

Volumetric air flow rate." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="AirFlowRateHistory_0h6sM0qRyHuO00025QrE$V" GlobalId="0h6sM0qRyHuO00025QrE$V" Name="AirFlowRateHistory" Description="Volumetric flow rate." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="AirFlowRateRange_2ApJq0qSuHuO00025QrE$V" GlobalId="2ApJq0qSuHuO00025QrE$V" Name="AirFlowRateRange" Description="Possible range of airflow that can be delivered." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="AirFlowRateRange_2qq320qSaHuO00025QrE$V" GlobalId="2qq320qSaHuO00025QrE$V" Name="AirFlowRateRange" Description="Possible range of airflow that can be delivered.

For cases where there is no airflow across the coil (e.g. electric coil in a floor slab), then the value is zero." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="AirFlowRateRange_2tBOq0qRyHuO00025QrE$V" GlobalId="2tBOq0qRyHuO00025QrE$V" Name="AirFlowRateRange" Description="Possible range of airflow that can be delivered.

Air flowrate range within which the air terminal is designed to operate." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="AirFlowRateRange_3_TqO0qTuHuO00025QrE$V" GlobalId="3_TqO0qTuHuO00025QrE$V" Name="AirFlowRateRange" Description="Possible range of airflow that can be delivered." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="AirFlowrateVersusFlowControlElement_1GNAE0qS0HuO00025QrE$V" GlobalId="1GNAE0qS0HuO00025QrE$V" Name="AirFlowrateVersusFlowControlElement" Description="Air flowrate versus flow control element position at nominal pressure drop." TemplateType="p_tablevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" SecondaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="AirFlowSensible_2pbRActdTExAvYvnFsgVBp" GlobalId="2pbRActdTExAvYvnFsgVBp" Name="AirFlowSensible" Description="" TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="AirFlowType_22N32mXRjDo92Q01qpFItv" GlobalId="22N32mXRjDo92Q01qpFItv" Name="AirFlowType" Description="" TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_AirTerminalAirFlowType">
						<EnumerationValues>
							<IfcLabel-wrapper>SUPPLYAIR</IfcLabel-wrapper>
							<IfcLabel-wrapper>RETURNAIR</IfcLabel-wrapper>
							<IfcLabel-wrapper>EXHAUSTAIR</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="AirHandlerConstruction_2jpX00qXCHuO00025QrE$V" GlobalId="2jpX00qXCHuO00025QrE$V" Name="AirHandlerConstruction" Description="Enumeration defining how the air handler might be fabricated." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_AirHandlerConstruction">
						<EnumerationValues>
							<IfcLabel-wrapper>MANUFACTUREDITEM</IfcLabel-wrapper>
							<IfcLabel-wrapper>CONSTRUCTEDONSITE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="AirHandlerFanCoilArrangement_2wwly0qXCHuO00025QrE$V" GlobalId="2wwly0qXCHuO00025QrE$V" Name="AirHandlerFanCoilArrangement" Description="Enumeration defining the arrangement of the supply air fan and the cooling coil." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_AirHandlerFanCoilArrangement">
						<EnumerationValues>
							<IfcLabel-wrapper>BLOWTHROUGH</IfcLabel-wrapper>
							<IfcLabel-wrapper>DRAWTHROUGH</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="AirHandlingName_3V3178UIjCuAR8LYKkcIXJ" GlobalId="3V3178UIjCuAR8LYKkcIXJ" Name="AirHandlingName" Description="The name of the air side system.

IfcRelServicesBuildings should be used to reference the correct AirHandlingSystem (IfcSystem)" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="AirParticleFilterType_17CVs0qUKHuO00025QrE$V" GlobalId="17CVs0qUKHuO00025QrE$V" Name="AirParticleFilterType" Description="A panel dry type extended surface filter is a dry-type air filter with random fiber mats or blankets in the forms of pockets, V-shaped or radial pleats, and include the following:
CoarseFilter: Filter with a efficiency lower than 30% for atmosphere dust-spot.
CoarseMetalScreen: Filter made of metal screen.
CoarseCellFoams: Filter made of cell foams.
CoarseSpunGlass: Filter made of spun glass.
MediumFilter: Filter with an efficiency between 30-98% for atmosphere dust-spot.
MediumElectretFilter: Filter with fine electret synthetic fibers.
MediumNaturalFiberFilter: Filter with natural fibers.
HEPAFilter: High efficiency particulate air filter.
ULPAFilter: Ultra low penetration air filter.
MembraneFilters: Filter made of membrane for certain pore diameters in flat sheet and pleated form.
A renewable media with a moving curtain viscous filter are random-fiber media coated with viscous substance in roll form or curtain where fresh media is fed across the face of the filter and the dirty media is rewound onto a roll at the bottom or to into a reservoir:
RollForm: Viscous filter used in roll form.
AdhesiveReservoir: Viscous filter used in moving curtain form.
A renewable moving curtain dry media filter is a random-fiber dry media of relatively high porosity used in moving-curtain(roll) filters.
An electrical filter uses electrostatic precipitation to remove and collect particulate contaminants." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_FilterAirParticleFilterType">
						<EnumerationValues>
							<IfcLabel-wrapper>COARSEMETALSCREEN</IfcLabel-wrapper>
							<IfcLabel-wrapper>COARSECELLFOAMS</IfcLabel-wrapper>
							<IfcLabel-wrapper>COARSESPUNGLASS</IfcLabel-wrapper>
							<IfcLabel-wrapper>MEDIUMELECTRETFILTER</IfcLabel-wrapper>
							<IfcLabel-wrapper>MEDIUMNATURALFIBERFILTER</IfcLabel-wrapper>
							<IfcLabel-wrapper>HEPAFILTER</IfcLabel-wrapper>
							<IfcLabel-wrapper>ULPAFILTER</IfcLabel-wrapper>
							<IfcLabel-wrapper>MEMBRANEFILTERS</IfcLabel-wrapper>
							<IfcLabel-wrapper>RENEWABLEMOVINGCURTIANDRYMEDIAFILTER</IfcLabel-wrapper>
							<IfcLabel-wrapper>ELECTRICALFILTER</IfcLabel-wrapper>
							<IfcLabel-wrapper>ROLLFORM</IfcLabel-wrapper>
							<IfcLabel-wrapper>ADHESIVERESERVOIR</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="AirPressure_0UInmj_h50IAIwdsP3KsR_" GlobalId="0UInmj_h50IAIwdsP3KsR_" Name="AirPressure" Description="Air pressure of nozzle." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="AirPressureDropCurve_0Hszw0qUeHuO00025QrE$V" GlobalId="0Hszw0qUeHuO00025QrE$V" Name="AirPressureDropCurve" Description="Air pressure drop as a function of air flow rate.

Air pressure drop versus air-flow rate." TemplateType="p_tablevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" SecondaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="AirPressureDropCurve_2nbMw0qU8HuO00025QrE$V" GlobalId="2nbMw0qU8HuO00025QrE$V" Name="AirPressureDropCurve" Description="Air pressure drop as a function of air flow rate." TemplateType="p_tablevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" SecondaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="AirPressureDropCurve_3EBwU0qTuHuO00025QrE$V" GlobalId="3EBwU0qTuHuO00025QrE$V" Name="AirPressureDropCurve" Description="Air pressure drop as a function of air flow rate." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="AirPressureDropCurveHistory_27WuA0qSaHuO00025QrE$V" GlobalId="27WuA0qSaHuO00025QrE$V" Name="AirPressureDropCurveHistory" Description="Air pressure drop curve, pressure drop – flow rate curve, AirPressureDrop = f (AirflowRate)." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" />
				<IfcSimplePropertyTemplate id="AirPressureDropCurves_1ozRa0qSuHuO00025QrE$V" GlobalId="1ozRa0qSuHuO00025QrE$V" Name="AirPressureDropCurves" Description="Air pressure drop as function of air flow rate." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="AirPressureDropCurves_260Oo0qS0HuO00025QrE$V" GlobalId="260Oo0qS0HuO00025QrE$V" Name="AirPressureDropCurves" Description="Air pressure drop as function of air flow rate." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" />
				<IfcSimplePropertyTemplate id="AirPressureRange_2P4rq0qRuHuO00025QrE$V" GlobalId="2P4rq0qRuHuO00025QrE$V" Name="AirPressureRange" Description="Allowable air static pressure range at the entrance of the air terminal box." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="AirPressurization_2Bpv00qWaHuO00025QrE$V" GlobalId="2Bpv00qWaHuO00025QrE$V" Name="AirPressurization" Description="Indication whether the space is required to have pressurized air (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="AirResistanceCurve_2vjDI0qWaHuO00025QrE$V" GlobalId="2vjDI0qWaHuO00025QrE$V" Name="AirResistanceCurve" Description="Air resistance curve (w/ fan only); Pressure = f ( flow rate)." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" />
				<IfcSimplePropertyTemplate id="AirSideSystemDistributionType_3p_8I0qRqHuO00025QrE$V" GlobalId="3p_8I0qRqHuO00025QrE$V" Name="AirSideSystemDistributionType" Description="This enumeration defines the basic types of air side systems (e.g., SingleDuct, DualDuct, Multizone, etc.)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_AirSideSystemDistributionType">
						<EnumerationValues>
							<IfcLabel-wrapper>SINGLEDUCT</IfcLabel-wrapper>
							<IfcLabel-wrapper>DUALDUCT</IfcLabel-wrapper>
							<IfcLabel-wrapper>MULTIZONE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="AirSideSystemType_3MAn_0qRqHuO00025QrE$V" GlobalId="3MAn_0qRqHuO00025QrE$V" Name="AirSideSystemType" Description="This enumeration specifies the basic types of possible air side systems (e.g., Constant Volume, Variable Volume, etc.)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_AirSideSystemType">
						<EnumerationValues>
							<IfcLabel-wrapper>CONSTANTVOLUME</IfcLabel-wrapper>
							<IfcLabel-wrapper>CONSTANTVOLUMESINGLEZONE</IfcLabel-wrapper>
							<IfcLabel-wrapper>CONSTANTVOLUMEMULTIPLEZONEREHEAT</IfcLabel-wrapper>
							<IfcLabel-wrapper>CONSTANTVOLUMEBYPASS</IfcLabel-wrapper>
							<IfcLabel-wrapper>VARIABLEAIRVOLUME</IfcLabel-wrapper>
							<IfcLabel-wrapper>VARIABLEAIRVOLUMEREHEAT</IfcLabel-wrapper>
							<IfcLabel-wrapper>VARIABLEAIRVOLUMEINDUCTION</IfcLabel-wrapper>
							<IfcLabel-wrapper>VARIABLEAIRVOLUMEFANPOWERED</IfcLabel-wrapper>
							<IfcLabel-wrapper>VARIABLEAIRVOLUMEDUALCONDUIT</IfcLabel-wrapper>
							<IfcLabel-wrapper>VARIABLEAIRVOLUMEVARIABLEDIFFUSERS</IfcLabel-wrapper>
							<IfcLabel-wrapper>VARIABLEAIRVOLUMEVARIABLETEMPERATURE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="AirTerminalLocation_0Fi5g0qRyHuO00025QrE$V" GlobalId="0Fi5g0qRyHuO00025QrE$V" Name="AirTerminalLocation" Description="Location  (a single type of diffuser can be used for multiple locations); high means close to ceiling." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_AirTerminalLocation">
						<EnumerationValues>
							<IfcLabel-wrapper>SIDEWALLHIGH</IfcLabel-wrapper>
							<IfcLabel-wrapper>SIDEWALLLOW</IfcLabel-wrapper>
							<IfcLabel-wrapper>CEILINGPERIMETER</IfcLabel-wrapper>
							<IfcLabel-wrapper>CEILINGINTERIOR</IfcLabel-wrapper>
							<IfcLabel-wrapper>FLOOR</IfcLabel-wrapper>
							<IfcLabel-wrapper>SILL</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="AirTerminalMountingType_3sz7I0qRyHuO00025QrE$V" GlobalId="3sz7I0qRyHuO00025QrE$V" Name="AirTerminalMountingType" Description="The way the air terminal is mounted to the ceiling, wall, etc.
Surface: mounted to the surface of something (e.g., wall, duct, etc.).
Flat flush: mounted flat and flush with a surface.
Lay-in: mounted in a lay-in type ceiling (e.g., a dropped ceiling grid)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_AirTerminalMountingType">
						<EnumerationValues>
							<IfcLabel-wrapper>SURFACE</IfcLabel-wrapper>
							<IfcLabel-wrapper>FLATFLUSH</IfcLabel-wrapper>
							<IfcLabel-wrapper>LAYIN</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="AirTerminalShape_1hUkE0qRyHuO00025QrE$V" GlobalId="1hUkE0qRyHuO00025QrE$V" Name="AirTerminalShape" Description="Shape of the air terminal. Slot is typically a long narrow supply device with an aspect ratio generally greater than 10 to 1." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_AirTerminalShape">
						<EnumerationValues>
							<IfcLabel-wrapper>ROUND</IfcLabel-wrapper>
							<IfcLabel-wrapper>RECTANGULAR</IfcLabel-wrapper>
							<IfcLabel-wrapper>SQUARE</IfcLabel-wrapper>
							<IfcLabel-wrapper>SLOT</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="AirVolume_2LIPiC_nX0J94McWTlYCrl" GlobalId="2LIPiC_nX0J94McWTlYCrl" Name="AirVolume" Description="Relative volume of air stratum constituents." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumeMeasure" />
				<IfcSimplePropertyTemplate id="AlarmCondition_0YAvE0qS4HuO00025QrE$V" GlobalId="0YAvE0qS4HuO00025QrE$V" Name="AlarmCondition" Description="Table mapping alarm condition identifiers to descriptive labels, which may be used for interpreting Pset_AlarmPHistory.Condition." TemplateType="p_tablevalue" PrimaryMeasureType="IfcIdentifier" SecondaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="AlkalinityConcentration_0ii580qUuHuO00025QrE$V" GlobalId="0ii580qUuHuO00025QrE$V" Name="AlkalinityConcentration" Description="Maximum alkalinity concentration (maximum sum of concentrations of each of the negative ions substances measured as CaCO3)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcIonConcentrationMeasure" />
				<IfcSimplePropertyTemplate id="AllowableHullPressure_3XuoFwqDfD$BTW3RD_z1qw" GlobalId="3XuoFwqDfD$BTW3RD_z1qw" Name="AllowableHullPressure" Description="Allowable contact pressure between fender and hull" TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="AmbientDesignDryBulbTemperature_3ftu60qSyHuO00025QrE$V" GlobalId="3ftu60qSyHuO00025QrE$V" Name="AmbientDesignDryBulbTemperature" Description="Ambient design dry bulb temperature used for selecting the cooling tower." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="AmbientDesignWetBulbTemperature_3lFCm0qSyHuO00025QrE$V" GlobalId="3lFCm0qSyHuO00025QrE$V" Name="AmbientDesignWetBulbTemperature" Description="Ambient design wet bulb temperature used for selecting the cooling tower." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="AmplifierType_3Nzk80qS4HuO00025QrE$V" GlobalId="3Nzk80qS4HuO00025QrE$V" Name="AmplifierType" Description="Indicates the type of amplifier." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_AudioVisualAmplifierType">
						<EnumerationValues>
							<IfcLabel-wrapper>FIXED</IfcLabel-wrapper>
							<IfcLabel-wrapper>VARIABLE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="AnchorageSlip_2UgD9v46jEhRDjnavSNqzR" GlobalId="2UgD9v46jEhRDjnavSNqzR" Name="AnchorageSlip" Description="The deformation of an anchor or slippage of tendons when the prestressing device is released." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="AnchorageType_2UZ$AxwvT8QOGM0IC5$_Zf" GlobalId="2UZ$AxwvT8QOGM0IC5$_Zf" Name="AnchorageType" Description="Mooring device anchorage type" TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_AnchorageType">
						<EnumerationValues>
							<IfcLabel-wrapper>CASTIN</IfcLabel-wrapper>
							<IfcLabel-wrapper>DRILLEDANDFIXED</IfcLabel-wrapper>
							<IfcLabel-wrapper>THROUGHBOLTED</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="AnchorBoltDiameter_3A38M0qV0HuO00025QrE$V" GlobalId="3A38M0qV0HuO00025QrE$V" Name="AnchorBoltDiameter" Description="The nominal diameter of the anchor bolt bar(s)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="AnchorBoltLength_33VWu0qV0HuO00025QrE$V" GlobalId="33VWu0qV0HuO00025QrE$V" Name="AnchorBoltLength" Description="The length of the anchor bolt." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="AnchorBoltProtrusionLength_3OypW0qV0HuO00025QrE$V" GlobalId="3OypW0qV0HuO00025QrE$V" Name="AnchorBoltProtrusionLength" Description="The length of the protruding part of the anchor bolt." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="AnchorBoltThreadLength_3Hp2e0qV0HuO00025QrE$V" GlobalId="3Hp2e0qV0HuO00025QrE$V" Name="AnchorBoltThreadLength" Description="The length of the threaded part of the anchor bolt." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="AngleBetweenComponentAxes_1E_Pu0qVKHuO00025QrE$V" GlobalId="1E_Pu0qVKHuO00025QrE$V" Name="AngleBetweenComponentAxes" Description="The angle between the axes of each pair of components." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="AngleToFirstAxis_1ADEe0qVKHuO00025QrE$V" GlobalId="1ADEe0qVKHuO00025QrE$V" Name="AngleToFirstAxis" Description="The angle of rotation of the axis of the first component relative to the ‘West’ edge of the slab." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="AnnualRange_1DcgPdRF13CubHGpnM9oNE" GlobalId="1DcgPdRF13CubHGpnM9oNE" Name="AnnualRange" Description="Indicative (95%-100%) annual range in levels." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="AnnualTrend_3akVvrLBLDmhqfr5tZOBIO" GlobalId="3akVvrLBLDmhqfr5tZOBIO" Name="AnnualTrend" Description="Indicative (95%-100%) annual rise in level." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="AntennaGain_3tDqS6zLnDv8qs_AhvaVI1" GlobalId="3tDqS6zLnDv8qs_AhvaVI1" Name="AntennaGain" Description="Indicates the antenna gain, which is a ratio of the power transmitted by an antenna in a specific direction compared to an isotropic antenna." TemplateType="p_singlevalue" PrimaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="AntennaType_2PysPrqKj3aPWcff71DZsA" GlobalId="2PysPrqKj3aPWcff71DZsA" Name="AntennaType" Description="Indicates the type of antenna.

Indicates the type of antenna integrated in the device." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="AntennaType_31c4VZLhD5Ve8keYZDr8ce" GlobalId="31c4VZLhD5Ve8keYZDr8ce" Name="AntennaType" Description="Indicates the type of antenna." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_AntennaType">
						<EnumerationValues>
							<IfcLabel-wrapper>CEILING</IfcLabel-wrapper>
							<IfcLabel-wrapper>PANEL</IfcLabel-wrapper>
							<IfcLabel-wrapper>YAGI</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ApertureAngle_38nOUEagv6fRIMFNX0p$i4" GlobalId="38nOUEagv6fRIMFNX0p$i4" Name="ApertureAngle" Description="Specifies the angle from which an arch rises." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="ApparentPower_2lYNHW98j2TeNYYr2i$746" GlobalId="2lYNHW98j2TeNYYr2i$746" Name="ApparentPower" Description="Apparent power." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="AppearanceGrade_1K1ny0qUuHuO00025QrE$V" GlobalId="1K1ny0qUuHuO00025QrE$V" Name="AppearanceGrade" Description="Grade with respect to visual quality." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ApplianceDiversity_00MVq0qX4HuO00025QrE$V" GlobalId="00MVq0qX4HuO00025QrE$V" Name="ApplianceDiversity" Description="Diversity of appliance load." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="ApplianceDiversity_0nzQY0qRuHuO00025QrE$V" GlobalId="0nzQY0qRuHuO00025QrE$V" Name="ApplianceDiversity" Description="Diversity of appliance load." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="AppliancePercentLoadToRadiant_0ggxg0qX4HuO00025QrE$V" GlobalId="0ggxg0qX4HuO00025QrE$V" Name="AppliancePercentLoadToRadiant" Description="Percent of sensible load to radiant heat." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="ApplicableStructuralDesignMethod_1rjDO0qUyHuO00025QrE$V" GlobalId="1rjDO0qUyHuO00025QrE$V" Name="ApplicableStructuralDesignMethod" Description="Determines whether mechanical material properties are applicable to &apos;ASD&apos; = allowable stress design (working stress design), &apos;LSD&apos; = limit state design, or &apos;LRFD&apos; = load and resistance factor design." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ApplicableStructuralDesignMethod_1uOlk0qUuHuO00025QrE$V" GlobalId="1uOlk0qUuHuO00025QrE$V" Name="ApplicableStructuralDesignMethod" Description="Determines whether mechanical material properties are applicable to &apos;ASD&apos; = allowable stress design (working stress design), &apos;LSD&apos; = limit state design, or &apos;LRFD&apos; = load and resistance factor design." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ApplicableStructuralDesignMethod_3Fuv3RpRzFVwibS5OOzpOY" GlobalId="3Fuv3RpRzFVwibS5OOzpOY" Name="ApplicableStructuralDesignMethod" Description="Determines whether mechanical material properties are applicable to &apos;ASD&apos; = allowable stress design (working stress design), &apos;LSD&apos; = limit state design, or &apos;LRFD&apos; = load and resistance factor design." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="Application_1QbS56uHrAi9fxNRgZLeWS" GlobalId="1QbS56uHrAi9fxNRgZLeWS" Name="Application" Description="Indicates application of controller." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ControllerApplication">
						<EnumerationValues>
							<IfcLabel-wrapper>MODEMCONTROLLER</IfcLabel-wrapper>
							<IfcLabel-wrapper>TELEPHONEDIRECTORY</IfcLabel-wrapper>
							<IfcLabel-wrapper>FANCOILUNITCONTROLLER</IfcLabel-wrapper>
							<IfcLabel-wrapper>ROOFTOPUNITCONTROLLER</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNITVENTILATORCONTROLLER</IfcLabel-wrapper>
							<IfcLabel-wrapper>SPACECONFORTCONTROLLER</IfcLabel-wrapper>
							<IfcLabel-wrapper>VAV</IfcLabel-wrapper>
							<IfcLabel-wrapper>PUMPCONTROLLER</IfcLabel-wrapper>
							<IfcLabel-wrapper>BOILERCONTROLLER</IfcLabel-wrapper>
							<IfcLabel-wrapper>DISCHARGEAIRCONTROLLER</IfcLabel-wrapper>
							<IfcLabel-wrapper>OCCUPANCYCONTROLLER</IfcLabel-wrapper>
							<IfcLabel-wrapper>CONSTANTLIGHTCONTROLLER</IfcLabel-wrapper>
							<IfcLabel-wrapper>SCENECONTROLLER</IfcLabel-wrapper>
							<IfcLabel-wrapper>PARTITIONWALLCONTROLLER</IfcLabel-wrapper>
							<IfcLabel-wrapper>REALTIMEKEEPER</IfcLabel-wrapper>
							<IfcLabel-wrapper>REALTIMEBASEDSCHEDULER</IfcLabel-wrapper>
							<IfcLabel-wrapper>LIGHTINGPANELCONTROLLER</IfcLabel-wrapper>
							<IfcLabel-wrapper>SUNBLINDCONTROLLER</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ApplicationMethod_3weM9ZLs9A9wkW7_awRCSv" GlobalId="3weM9ZLs9A9wkW7_awRCSv" Name="ApplicationMethod" Description="State the application method used... e.g. spray, extruded" TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="ApplicationOfFan_3Fhvw0qUCHuO00025QrE$V" GlobalId="3Fhvw0qUCHuO00025QrE$V" Name="ApplicationOfFan" Description="The functional application of the fan.
SupplyAir: Supply air fan.
ReturnAir: Return air fan.
ExhaustAir: Exhaust air fan.
Other: Other type of application not defined above." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_FanApplicationType">
						<EnumerationValues>
							<IfcLabel-wrapper>SUPPLYAIR</IfcLabel-wrapper>
							<IfcLabel-wrapper>RETURNAIR</IfcLabel-wrapper>
							<IfcLabel-wrapper>EXHAUSTAIR</IfcLabel-wrapper>
							<IfcLabel-wrapper>COOLINGTOWER</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ApplicationTemperature_2GA6uBu4jFeRzE7Yu7b791" GlobalId="2GA6uBu4jFeRzE7Yu7b791" Name="ApplicationTemperature" Description="Indicates the ambient temperature at which the course is applied" TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="AppliedLineLoad_3T5jes7obFcB3kXbkF_EPE" GlobalId="3T5jes7obFcB3kXbkF_EPE" Name="AppliedLineLoad" Description="The load of line where the derailer is installed. It is a design parameter and is defined by mass per length." TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassPerLengthMeasure" />
				<IfcSimplePropertyTemplate id="AppliesToTrainCategory_3oA0EztgbEguYGMhtbbFi2" GlobalId="3oA0EztgbEguYGMhtbbFi2" Name="AppliesToTrainCategory" Description="Sign information relative to train category, e.g. freight, passenger." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_TrainCategory">
						<EnumerationValues>
							<IfcLabel-wrapper>FREIGHT</IfcLabel-wrapper>
							<IfcLabel-wrapper>PASSENGER</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ApproachSpeed_2khyDboNP4W87sfeq3cm4L" GlobalId="2khyDboNP4W87sfeq3cm4L" Name="ApproachSpeed" Description="The design speed of trains approaching the signal if different from the line speed." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLinearVelocityMeasure" />
				<IfcSimplePropertyTemplate id="ArcExtinctionType_1iKRDrl9j6IQuyzsIknVc2" GlobalId="1iKRDrl9j6IQuyzsIknVc2" Name="ArcExtinctionType" Description="Type of arc extinction used." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="AreaDensity_2zXs$B2Bz2kxUwiWQyK1Os" GlobalId="2zXs$B2Bz2kxUwiWQyK1Os" Name="AreaDensity" Description="Specifies a weight per area unit for the mesh." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAreaDensityMeasure" />
				<IfcSimplePropertyTemplate id="AreaID_1LX3rTqy19RRHx3VNZyWTI" GlobalId="1LX3rTqy19RRHx3VNZyWTI" Name="AreaID" Description="Identification of the single, specific mapped feature in the same mapped zone.
&gt;NOTE Mapped zone is represented in IFC using _IfcSpatialZone_ with PredefinedType _MAPPEDZONE_." TemplateType="p_singlevalue" PrimaryMeasureType="IfcIdentifier" />
				<IfcSimplePropertyTemplate id="AreaOfInterest_1KWCYITgX9jOp69TrRoKW5" GlobalId="1KWCYITgX9jOp69TrRoKW5" Name="AreaOfInterest" Description="Reference to geographical gazeetteer entries (France, Paris basin etc). 
&gt;NOTE Geonames (https://www.geonames.org/) could be used in case no other is available." TemplateType="p_singlevalue" PrimaryMeasureType="IfcIdentifier" />
				<IfcSimplePropertyTemplate id="AreaPerOccupant_3WlzO0qWeHuO00025QrE$V" GlobalId="3WlzO0qWeHuO00025QrE$V" Name="AreaPerOccupant" Description="Design occupancy loading for this type of usage assigned to this space." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAreaMeasure" />
				<IfcSimplePropertyTemplate id="AreHolesGrouted_2pEnnTgZ57F8CFzhnE6a87" GlobalId="2pEnnTgZ57F8CFzhnE6a87" Name="AreHolesGrouted" Description="Specifies whether holes are grouted after insertion of pipes/bars." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="Arrangement_24IjDcPPnCph3L6$aDInL7" GlobalId="24IjDcPPnCph3L6$aDInL7" Name="Arrangement" Description="Specifies whether the pre-support is simple or staggered." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_PreSupportArrangement">
						<EnumerationValues>
							<IfcLabel-wrapper>SIMPLE</IfcLabel-wrapper>
							<IfcLabel-wrapper>STAGGERED</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Arrangement_2knBvrIPHFUBYQTIun1d_A" GlobalId="2knBvrIPHFUBYQTIun1d_A" Name="Arrangement" Description="Shopuld reuse Arrangement_24IjDcPPnCph3L6aDInL7 from PSet_PreSupportCommon." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ArrangementType_2dONa0qRuHuO00025QrE$V" GlobalId="2dONa0qRuHuO00025QrE$V" Name="ArrangementType" Description="Terminal box arrangement.
SingleDuct: Terminal box receives warm or cold air from a single air supply duct.
DualDuct: Terminal box receives warm and cold air from separate air supply ducts." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_AirTerminalBoxArrangementType">
						<EnumerationValues>
							<IfcLabel-wrapper>SINGLEDUCT</IfcLabel-wrapper>
							<IfcLabel-wrapper>DUALDUCT</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ArticleNumber_1_Lzq0qUmHuO00025QrE$V" GlobalId="1_Lzq0qUmHuO00025QrE$V" Name="ArticleNumber" Description="Article number or reference that is be applied to a configured product according to a standard scheme for article number definition as defined by the manufacturer. It is often used as the purchasing number." TemplateType="p_singlevalue" PrimaryMeasureType="IfcIdentifier" />
				<IfcSimplePropertyTemplate id="ArtificialLighting_2rFEk0qWeHuO00025QrE$V" GlobalId="2rFEk0qWeHuO00025QrE$V" Name="ArtificialLighting" Description="Indication whether this space requires artificial lighting (as natural lighting would be not sufficient). (TRUE) indicates yes (FALSE) otherwise." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="AsbestosPotential_3Kf7Ic90PCrOHQqSF4YAvL" GlobalId="3Kf7Ic90PCrOHQqSF4YAvL" Name="AsbestosPotential" Description="Description or rating of the potential presence of asbestos in the ground." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="AsBuiltInjectionDuration_1v8RCK9RDAFeJdKmW$Cunu" GlobalId="1v8RCK9RDAFeJdKmW$Cunu" Name="AsBuiltInjectionDuration" Description="The time spent for the injection work." TemplateType="p_singlevalue" PrimaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="AsBuiltLocationNumber_1d7Es0qVGHuO00025QrE$V" GlobalId="1d7Es0qVGHuO00025QrE$V" Name="AsBuiltLocationNumber" Description="Defines a unique location within a structure, the ‘slot’ into which the piece was installed. Where pieces share the same piece mark, they can be interchanged. The value is only known after erection." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="AsContent_3gj7BIvwT8S8u8sGvaHIBb" GlobalId="3gj7BIvwT8S8u8sGvaHIBb" Name="AsContent" Description="Content of Arsenic. The unit must be defined in _&apos;IfcPropertySingleValue_._Unit&apos;_." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="AspectRatio_1fn65ZfW93URZlaV1DMSyD" GlobalId="1fn65ZfW93URZlaV1DMSyD" Name="AspectRatio" Description="Length/Diameter of fibre." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="AspectRatio_3kzVu0qTeHuO00025QrE$V" GlobalId="3kzVu0qTeHuO00025QrE$V" Name="AspectRatio" Description="The default aspect ratio." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="AssemblyInstruction_3W5i6nbkP9NBt_M6PTB5jW" GlobalId="3W5i6nbkP9NBt_M6PTB5jW" Name="AssemblyInstruction" Description="Instructions to describe how the system / equipment / facility is assembled." TemplateType="p_referencevalue" PrimaryMeasureType="IfcExternalReference" />
				<IfcSimplePropertyTemplate id="AssemblyPlace_1YL3k0qUmHuO00025QrE$V" GlobalId="1YL3k0qUmHuO00025QrE$V" Name="AssemblyPlace" Description="Enumeration defining where the assembly is intended to take place, either in a factory, other offsite location or on the building site." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" id="i188" Name="PEnum_AssemblyPlace">
						<EnumerationValues>
							<IfcLabel-wrapper>FACTORY</IfcLabel-wrapper>
							<IfcLabel-wrapper>OFFSITE</IfcLabel-wrapper>
							<IfcLabel-wrapper>SITE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="AssemblyPlace_2V83A0qUmHuO00025QrE$V" GlobalId="2V83A0qUmHuO00025QrE$V" Name="AssemblyPlace" Description="Enumeration defining where the assembly is intended to take place, either in a factory, other offsite location or on the building site." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i188" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="AssessmentCondition_3Rt360qSmHuO00025QrE$V" GlobalId="3Rt360qSmHuO00025QrE$V" Name="AssessmentCondition" Description="The overall condition of a product based on an assessment of the contributions to the overall condition made by the various criteria considered. The meanings given to the values of assessed condition should be agreed and documented by local agreements. For instance, is overall condition measured on a scale of 1 - 10 or by assigning names such as Good, OK, Poor." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="AssessmentDate_3N5ts0qSmHuO00025QrE$V" GlobalId="3N5ts0qSmHuO00025QrE$V" Name="AssessmentDate" Description="Date on which the overall condition is assessed" TemplateType="p_singlevalue" PrimaryMeasureType="IfcDate" />
				<IfcSimplePropertyTemplate id="AssessmentDescription_3XENm0qSmHuO00025QrE$V" GlobalId="3XENm0qSmHuO00025QrE$V" Name="AssessmentDescription" Description="Qualitative description of the condition." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="AssessmentFrequency_3Y5J0kLVfDHfMH8$QTwre7" GlobalId="3Y5J0kLVfDHfMH8$QTwre7" Name="AssessmentFrequency" Description="Indicates how often the equipment should be assessed, to have a clear estimation on its working state, based on which the maintenance staff can decide whether it requires maintenance or requires to be updated or replaced." TemplateType="p_singlevalue" PrimaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="AssessmentMethod_0jlpIbRpH4Hhz2PKb2XqoO" GlobalId="0jlpIbRpH4Hhz2PKb2XqoO" Name="AssessmentMethod" Description="External reference to assessment method or application used to perform the assessment." TemplateType="p_referencevalue" PrimaryMeasureType="IfcDocumentReference" />
				<IfcSimplePropertyTemplate id="AssessmentType_3NSPfml8jBXg1KRcsojDrC" GlobalId="3NSPfml8jBXg1KRcsojDrC" Name="AssessmentType" Description="Category of latest condition assessment report of the asset." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="AssetAccountingType_2AUdK0qS4HuO00025QrE$V" GlobalId="2AUdK0qS4HuO00025QrE$V" Name="AssetAccountingType" Description="Identifies the predefined types of risk from which the type required may be set." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_AssetAccountingType">
						<EnumerationValues>
							<IfcLabel-wrapper>FIXED</IfcLabel-wrapper>
							<IfcLabel-wrapper>NONFIXED</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="AssetCriticality_3gS4Hpk8L3vgoq4ExCulT5" GlobalId="3gS4Hpk8L3vgoq4ExCulT5" Name="AssetCriticality" Description="Rating of the asset&apos;s criticality to the operation of the facility" TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" id="i199" Name="PEnum_AssetRating">
						<EnumerationValues>
							<IfcLabel-wrapper>VERYHIGH</IfcLabel-wrapper>
							<IfcLabel-wrapper>HIGH</IfcLabel-wrapper>
							<IfcLabel-wrapper>MODERATE</IfcLabel-wrapper>
							<IfcLabel-wrapper>LOW</IfcLabel-wrapper>
							<IfcLabel-wrapper>VERYLOW</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="AssetFrailty_00miw_eHPA8P5HEVj_170C" GlobalId="00miw_eHPA8P5HEVj_170C" Name="AssetFrailty" Description="Rating of the asset&apos;s frailty to breakage or deterioration" TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i199" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="AssetIdentifier_3_jQ0YjzL52QWb$SZ4jXPk" GlobalId="3_jQ0YjzL52QWb$SZ4jXPk" Name="AssetIdentifier" Description="A unique identification assigned to an asset that enables its differentiation from other assets.

&gt; NOTE&amp;nbsp; The asset identifier is unique within the asset register. It differs from the globally unique id assigned to the instance of an entity populating a database." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="AssetInsuranceType_2eHze0qS4HuO00025QrE$V" GlobalId="2eHze0qS4HuO00025QrE$V" Name="AssetInsuranceType" Description="Identifies the predefined types of insurance rating from which the type required may be set." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_AssetInsuranceType">
						<EnumerationValues>
							<IfcLabel-wrapper>PERSONAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>REAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="AssetPriority_2a$iGZQAL2IB_7weB7s430" GlobalId="2a$iGZQAL2IB_7weB7s430" Name="AssetPriority" Description="Combined criticality and frailty rating indicating the operational and maintenance priority of the asset" TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i199" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="AssetStatus_14BbPbaD55EupvLyhdsrvG" GlobalId="14BbPbaD55EupvLyhdsrvG" Name="AssetStatus" Description="Current status or stage in life cycle." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="AssetTaxType_2P_Ru0qS4HuO00025QrE$V" GlobalId="2P_Ru0qS4HuO00025QrE$V" Name="AssetTaxType" Description="Identifies the predefined types of taxation group from which the type required may be set." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_AssetTaxType">
						<EnumerationValues>
							<IfcLabel-wrapper>CAPITALISED</IfcLabel-wrapper>
							<IfcLabel-wrapper>EXPENSED</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="AssetUse_1FqkTRAnDBMPRCYYM1pIPQ" GlobalId="1FqkTRAnDBMPRCYYM1pIPQ" Name="AssetUse" Description="General use category of the asset" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="AssociatedActivity_2AF5ccxkDDlOGOFWk7ITai" GlobalId="2AF5ccxkDDlOGOFWk7ITai" Name="AssociatedActivity" Description="An indication or link to any associated activity or process that may trigger the hazard. If used directly on an annotation or semantic object. for an alternative see group use encoding template" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="AssociatedLocation_0KVR2PgJn4_ublMgB8xxwD" GlobalId="0KVR2PgJn4_ublMgB8xxwD" Name="AssociatedLocation" Description="An indication or link to any associated location or space that may trigger the hazard. If used directly on an annotation or semantic object. for an alternative see group use encoding template" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="AssociatedProduct_139f3ZZq14mvqATf6iPSJ3" GlobalId="139f3ZZq14mvqATf6iPSJ3" Name="AssociatedProduct" Description="An indication or link to any associated product or material that may trigger the hazard. If used directly on an annotation or semantic object. for an alternative see group use encoding template" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="AtexVerified_0i7hW0qVmHuO00025QrE$V" GlobalId="0i7hW0qVmHuO00025QrE$V" Name="AtexVerified" Description="An indication whether the tripping_unit is verified to be applied in EX-environment or not." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="AtmosphericAcidification_0VZMO0qU8HuO00025QrE$V" GlobalId="0VZMO0qU8HuO00025QrE$V" Name="AtmosphericAcidification" Description="Quantity of gases responsible for the atmospheric acidification calculated in equivalent SO2." TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassMeasure" />
				<IfcSimplePropertyTemplate id="AtmosphericAcidificationPerUnit_3982U0qU4HuO00025QrE$V" GlobalId="3982U0qU4HuO00025QrE$V" Name="AtmosphericAcidificationPerUnit" Description="Quantity of gases responsible for the atmospheric acidification calculated in equivalent SO2" TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassMeasure" />
				<IfcSimplePropertyTemplate id="AtmosphericPressure_1FEcy0qTuHuO00025QrE$V" GlobalId="1FEcy0qTuHuO00025QrE$V" Name="AtmosphericPressure" Description="Ambient atmospheric pressure." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="AtmosphericPressure_1XfB20qRuHuO00025QrE$V" GlobalId="1XfB20qRuHuO00025QrE$V" Name="AtmosphericPressure" Description="Ambient atmospheric pressure." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="AtmosphericPressure_24Y980qSaHuO00025QrE$V" GlobalId="24Y980qSaHuO00025QrE$V" Name="AtmosphericPressure" Description="Ambient atmospheric pressure." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="AtmosphericPressure_2OG$20qUaHuO00025QrE$V" GlobalId="2OG$20qUaHuO00025QrE$V" Name="AtmosphericPressure" Description="Ambient atmospheric pressure." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="AtmosphericPressure_3upJ20qTqHuO00025QrE$V" GlobalId="3upJ20qTqHuO00025QrE$V" Name="AtmosphericPressure" Description="Ambient atmospheric pressure." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="Attenuation_0Fn9Y3Mh90ghP0udRXs1Jj" GlobalId="0Fn9Y3Mh90ghP0udRXs1Jj" Name="Attenuation" Description="Indicates the optical or electrical attenuation of the cable measured in dB, at a certain wavelength or frequency, changing with the length of the cable." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="AudioAmplification_1wOvK0qSCHuO00025QrE$V" GlobalId="1wOvK0qSCHuO00025QrE$V" Name="AudioAmplification" Description="Indicates audio amplification frequency ranges." TemplateType="p_tablevalue" PrimaryMeasureType="IfcFrequencyMeasure" SecondaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="AudioAmplification_3cHFu0qS4HuO00025QrE$V" GlobalId="3cHFu0qS4HuO00025QrE$V" Name="AudioAmplification" Description="Indicates audio amplification frequency ranges." TemplateType="p_tablevalue" PrimaryMeasureType="IfcFrequencyMeasure" SecondaryMeasureType="IfcSoundPowerMeasure" />
				<IfcSimplePropertyTemplate id="AudioMode_23L6Q0qSCHuO00025QrE$V" GlobalId="23L6Q0qSCHuO00025QrE$V" Name="AudioMode" Description="Indicates audio sound modes and corresponding labels, if applicable." TemplateType="p_tablevalue" PrimaryMeasureType="IfcIdentifier" SecondaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="AudioMode_3kdJa0qS4HuO00025QrE$V" GlobalId="3kdJa0qS4HuO00025QrE$V" Name="AudioMode" Description="Indicates audio sound modes and corresponding labels, if applicable." TemplateType="p_tablevalue" PrimaryMeasureType="IfcIdentifier" SecondaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="AudioMode_3s4H80qS8HuO00025QrE$V" GlobalId="3s4H80qS8HuO00025QrE$V" Name="AudioMode" Description="Indicates audio sound modes and corresponding labels, if applicable." TemplateType="p_tablevalue" PrimaryMeasureType="IfcIdentifier" SecondaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="AudioVolume_1vVZE0qS8HuO00025QrE$V" GlobalId="1vVZE0qS8HuO00025QrE$V" Name="AudioVolume" Description="Indicates discrete audio volume levels and corresponding sound power offsets, if applicable. Missing values may be interpolated." TemplateType="p_tablevalue" PrimaryMeasureType="IfcInteger" SecondaryMeasureType="IfcSoundPowerMeasure" />
				<IfcSimplePropertyTemplate id="AudioVolumeHistory_3AsVC0qS4HuO00025QrE$V" GlobalId="3AsVC0qS4HuO00025QrE$V" Name="AudioVolumeHistory" Description="Indicates the audio volume level where the integer level corresponds to an entry or interpolation within Pset_AudioVisualApplianceTypeCommon.AudioVolume." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcInteger" />
				<IfcSimplePropertyTemplate id="Authors_1oQcJRV0j0WhD1ng6TcHzF" GlobalId="1oQcJRV0j0WhD1ng6TcHzF" Name="Authors" Description="Name of the author(s) involved in producing the model." TemplateType="p_listvalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="AutomaticCondensateDischarge_0bXKO0qUOHuO00025QrE$V" GlobalId="0bXKO0qUOHuO00025QrE$V" Name="AutomaticCondensateDischarge" Description="Whether or not the condensing water or oil is discharged automatically from the filter." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="AuxiliaryEnergyConsumption_1RiSu0qSGHuO00025QrE$V" GlobalId="1RiSu0qSGHuO00025QrE$V" Name="AuxiliaryEnergyConsumption" Description="Boiler secondary energy source consumption (i.e., the electricity consumed by electrical devices such as fans and pumps)." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="AuxiliaryEnergySourceConsumption_2joHA0qWaHuO00025QrE$V" GlobalId="2joHA0qWaHuO00025QrE$V" Name="AuxiliaryEnergySourceConsumption" Description="Auxiliary energy source consumption." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" />
				<IfcSimplePropertyTemplate id="AverageBoreholeDepth_3NM6PipTTFyvqSdj8magOF" GlobalId="3NM6PipTTFyvqSdj8magOF" Name="AverageBoreholeDepth" Description="Average depth of boreholes used for dewatering." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="AvgDepthToTreatment_0k1nV7tkL5ZBpjOwXLSwpl" GlobalId="0k1nV7tkL5ZBpjOwXLSwpl" Name="AvgDepthToTreatment" Description="Average depth to treatment." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="AvgTreatmentDepth_2ATszB7MD5rOdgrmtnn2wi" GlobalId="2ATszB7MD5rOdgrmtnn2wi" Name="AvgTreatmentDepth" Description="Average depth of boreholes used for treatment." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="AvgTreatmentSpacing_3IwKbHD4H2mxQff$jGfKO3" GlobalId="3IwKbHD4H2mxQff$jGfKO3" Name="AvgTreatmentSpacing" Description="Average spacing of boreholes used for treatment." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="AvgTreatmentThickness_2FJiKS$wbFmwMZU50OhXL8" GlobalId="2FJiKS$wbFmwMZU50OhXL8" Name="AvgTreatmentThickness" Description="Average treatment thickness." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="AxleCounterResponseTime_3BJLDYF6PEFRJQcM08GUi3" GlobalId="3BJLDYF6PEFRJQcM08GUi3" Name="AxleCounterResponseTime" Description="The time that axle counter can detect the axles of locomotive and vehicle." TemplateType="p_singlevalue" PrimaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="AxleCountingEquipmentType_0USybSq193BewNju5coT5m" GlobalId="0USybSq193BewNju5coT5m" Name="AxleCountingEquipmentType" Description="The type of axle counting equipment." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_AxleCountingEquipmentType">
						<EnumerationValues>
							<IfcLabel-wrapper>EVALUATOR</IfcLabel-wrapper>
							<IfcLabel-wrapper>WHEELDETECTOR</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Azimuth_36E2s0qWSHuO00025QrE$V" GlobalId="36E2s0qWSHuO00025QrE$V" Name="Azimuth" Description="The azimuth of the outward normal for the outward or upward facing surface." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="AzimuthExposure_287QddVQ16w8cApdbLY7_Q" GlobalId="287QddVQ16w8cApdbLY7_Q" Name="AzimuthExposure" Description="The azimuth of a slope orientation describes a horizontal line perpendicular to dip direction of the slope. The azimuth is given in degrees in the range 0 to 360 degrees counted clockwise from true north and expressed as a three-digit number, e.g. 240 or 015. 
&gt;NOTE Definition according to ISO14689." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="AzimuthHingeLine_39UFUKWgf4gOAXmd1DKyEZ" GlobalId="39UFUKWgf4gOAXmd1DKyEZ" Name="AzimuthHingeLine" Description="The azimuth of the hinge line of the fold. The azimuth is given in degrees in the range 0 to 360 degrees counted clockwise from true north and expressed as a three-digit number, e.g. 240 or 015." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="AzimuthHingeLineation_1bK1xqeB57exCDB4QMcG7Z" GlobalId="1bK1xqeB57exCDB4QMcG7Z" Name="AzimuthHingeLineation" Description="The azimuth of the lineation. The azimuth is given in degrees in the range 0 to 360 degrees counted clockwise from true north and expressed as a three-digit number, e.g. 240 or 015." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="BackboardType_2AeuY0f$T5tOa37WsvTOTr" GlobalId="2AeuY0f$T5tOa37WsvTOTr" Name="BackboardType" Description="The type of the backboard of the signal frame." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="BackflowPreventerType_2aUtu0qUWHuO00025QrE$V" GlobalId="2aUtu0qUWHuO00025QrE$V" Name="BackflowPreventerType" Description="Identifies the type of backflow preventer installed to prevent the backflow of contaminated or polluted water from an irrigation/reticulation system to a potable water supply." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_BackflowPreventerType">
						<EnumerationValues>
							<IfcLabel-wrapper>NONE</IfcLabel-wrapper>
							<IfcLabel-wrapper>ATMOSPHERICVACUUMBREAKER</IfcLabel-wrapper>
							<IfcLabel-wrapper>ANTISIPHONVALVE</IfcLabel-wrapper>
							<IfcLabel-wrapper>DOUBLECHECKBACKFLOWPREVENTER</IfcLabel-wrapper>
							<IfcLabel-wrapper>PRESSUREVACUUMBREAKER</IfcLabel-wrapper>
							<IfcLabel-wrapper>REDUCEDPRESSUREBACKFLOWPREVENTER</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="BackInletPatternType_1ftGe0qXSHuO00025QrE$V" GlobalId="1ftGe0qXSHuO00025QrE$V" Name="BackInletPatternType" Description="Identifies the pattern of inlet connections to a gully trap.

A gulley trap may have 0,1,2,3 or 4 inlet connections and the pattern of their arrangement may vary. The enumeration makes the convention that an outlet is either vertical or is placed at the bottom (south side) of the gully trap (when viewed in plan). Position 1 is to the left (west), position 2 is to the top (north), position 3 is to the right (east) and position 4 is to the bottom (south).

               2
               |
   ----------------
   !                       |
1-|                       |-3
   !                       |
   ----------------
               |
              4" TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" id="i248" Name="PEnum_BackInletPatternType">
						<EnumerationValues>
							<IfcLabel-wrapper>NONE</IfcLabel-wrapper>
							<IfcLabel-wrapper>1</IfcLabel-wrapper>
							<IfcLabel-wrapper>2</IfcLabel-wrapper>
							<IfcLabel-wrapper>3</IfcLabel-wrapper>
							<IfcLabel-wrapper>4</IfcLabel-wrapper>
							<IfcLabel-wrapper>12</IfcLabel-wrapper>
							<IfcLabel-wrapper>13</IfcLabel-wrapper>
							<IfcLabel-wrapper>14</IfcLabel-wrapper>
							<IfcLabel-wrapper>23</IfcLabel-wrapper>
							<IfcLabel-wrapper>24</IfcLabel-wrapper>
							<IfcLabel-wrapper>34</IfcLabel-wrapper>
							<IfcLabel-wrapper>123</IfcLabel-wrapper>
							<IfcLabel-wrapper>124</IfcLabel-wrapper>
							<IfcLabel-wrapper>134</IfcLabel-wrapper>
							<IfcLabel-wrapper>234</IfcLabel-wrapper>
							<IfcLabel-wrapper>1234</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="BackInletPatternType_3qlWI0qXSHuO00025QrE$V" GlobalId="3qlWI0qXSHuO00025QrE$V" Name="BackInletPatternType" Description="Identifies the pattern of inlet connections to a gully trap.

A gulley trap may have 0,1,2,3 or 4 inlet connections and the pattern of their arrangement may vary. The enumeration makes the convention that an outlet is either vertical or is placed at the bottom (south side) of the gully trap (when viewed in plan). Position 1 is to the left (west), position 2 is to the top (north), position 3 is to the right (east) and position 4 is to the bottom (south).

               2
               |
   ----------------
   !                       |
1-|                       |-3
   !                       |
   ----------------
               |
              4" TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i248" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="BackupSupplySystem_0QDHa0qUmHuO00025QrE$V" GlobalId="0QDHa0qUmHuO00025QrE$V" Name="BackupSupplySystem" Description="The type of backup supply system." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_BackupSupplySystemType">
						<EnumerationValues>
							<IfcLabel-wrapper>LOCALBATTERY</IfcLabel-wrapper>
							<IfcLabel-wrapper>CENTRALBATTERY</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="BandWidth_3qGbr0Q199cuUUYiO3nY0i" GlobalId="3qGbr0Q199cuUUYiO3nY0i" Name="BandWidth" Description="Indicates the bandwidth for telecommunication of the device." TemplateType="p_singlevalue" PrimaryMeasureType="IfcFrequencyMeasure" />
				<IfcSimplePropertyTemplate id="BarAllocationType_38Ihu0qW0HuO00025QrE$V" GlobalId="38Ihu0qW0HuO00025QrE$V" Name="BarAllocationType" Description="Defines the type of the reinforcement bar allocation." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ReinforcementBarAllocationType">
						<EnumerationValues>
							<IfcLabel-wrapper>SINGLE</IfcLabel-wrapper>
							<IfcLabel-wrapper>DOUBLE</IfcLabel-wrapper>
							<IfcLabel-wrapper>ALTERNATE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>USERDEFINED</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTDEFINED</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="BarCode_1H2oy0qUmHuO00025QrE$V" GlobalId="1H2oy0qUmHuO00025QrE$V" Name="BarCode" Description="The identity of the bar code given to an occurrence of the product." TemplateType="p_singlevalue" PrimaryMeasureType="IfcIdentifier" />
				<IfcSimplePropertyTemplate id="BarSectionType_36JQMyGJDC7xRwd_60klq0" GlobalId="36JQMyGJDC7xRwd_60klq0" Name="BarSectionType" Description="Type of cross section of the bar." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_BarSectionType">
						<EnumerationValues>
							<IfcLabel-wrapper>SMOOTH</IfcLabel-wrapper>
							<IfcLabel-wrapper>RIBBED</IfcLabel-wrapper>
							<IfcLabel-wrapper>HOLLOW</IfcLabel-wrapper>
							<IfcLabel-wrapper>USERDEFINED</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTDEFINED</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="BaseChamfer_3fMU60qVKHuO00025QrE$V" GlobalId="3fMU60qVKHuO00025QrE$V" Name="BaseChamfer" Description="Base chamfer of the profile." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNonNegativeLengthMeasure" />
				<IfcSimplePropertyTemplate id="BaseMaterial_0A4J_0qTGHuO00025QrE$V" GlobalId="0A4J_0qTGHuO00025QrE$V" Name="BaseMaterial" Description="The material from which the base of the chamber is constructed.
NOTE: It is assumed that chamber base will be constructed of a single material." TemplateType="p_referencevalue" PrimaryMeasureType="IfcMaterialDefinition" />
				<IfcSimplePropertyTemplate id="BaseMaterial_1IC680qTGHuO00025QrE$V" GlobalId="1IC680qTGHuO00025QrE$V" Name="BaseMaterial" Description="The material from which the base of the chamber is constructed.
NOTE: It is assumed that chamber base will be constructed of a single material." TemplateType="p_referencevalue" PrimaryMeasureType="IfcMaterialDefinition" />
				<IfcSimplePropertyTemplate id="BaseMaterial_2iCIU0qTGHuO00025QrE$V" GlobalId="2iCIU0qTGHuO00025QrE$V" Name="BaseMaterial" Description="The material from which the base of the chamber is constructed.
NOTE: It is assumed that chamber base will be constructed of a single material." TemplateType="p_referencevalue" PrimaryMeasureType="IfcMaterialDefinition" />
				<IfcSimplePropertyTemplate id="BaseMaterial_2m47e0qTCHuO00025QrE$V" GlobalId="2m47e0qTCHuO00025QrE$V" Name="BaseMaterial" Description="The material from which the base of the chamber is constructed.
NOTE: It is assumed that chamber base will be constructed of a single material." TemplateType="p_referencevalue" PrimaryMeasureType="IfcMaterialDefinition" />
				<IfcSimplePropertyTemplate id="BaseThickness_23N6A0qTCHuO00025QrE$V" GlobalId="23N6A0qTCHuO00025QrE$V" Name="BaseThickness" Description="The thickness of the base construction, assumed to be constructed at a single thickness." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="BaseThickness_2p2sg0qTCHuO00025QrE$V" GlobalId="2p2sg0qTCHuO00025QrE$V" Name="BaseThickness" Description="The thickness of the base construction, assumed to be constructed at a single thickness." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="BaseType_25X_Q0qVuHuO00025QrE$V" GlobalId="25X_Q0qVuHuO00025QrE$V" Name="BaseType" Description="Defines general types of pump bases.

FRAME: Frame.
BASE: Base.
NONE: There is no pump base, such as an inline pump.
OTHER: Other type of pump base." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_PumpBaseType">
						<EnumerationValues>
							<IfcLabel-wrapper>FRAME</IfcLabel-wrapper>
							<IfcLabel-wrapper>BASE</IfcLabel-wrapper>
							<IfcLabel-wrapper>NONE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="BasinReserveVolume_3MD1i0qSyHuO00025QrE$V" GlobalId="3MD1i0qSyHuO00025QrE$V" Name="BasinReserveVolume" Description="Volume between operating and overflow levels in cooling tower basin." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumeMeasure" />
				<IfcSimplePropertyTemplate id="BatchReference_1SNbg0qUmHuO00025QrE$V" GlobalId="1SNbg0qUmHuO00025QrE$V" Name="BatchReference" Description="The identity of the batch reference from which an occurrence of a product is taken." TemplateType="p_singlevalue" PrimaryMeasureType="IfcIdentifier" />
				<IfcSimplePropertyTemplate id="BathType_3GLos0qW4HuO00025QrE$V" GlobalId="3GLos0qW4HuO00025QrE$V" Name="BathType" Description="The property enumeration defines the types of bath that may be specified within the property set." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_BathType">
						<EnumerationValues>
							<IfcLabel-wrapper>DOMESTIC</IfcLabel-wrapper>
							<IfcLabel-wrapper>FOOT</IfcLabel-wrapper>
							<IfcLabel-wrapper>POOL</IfcLabel-wrapper>
							<IfcLabel-wrapper>PLUNGE</IfcLabel-wrapper>
							<IfcLabel-wrapper>SITZ</IfcLabel-wrapper>
							<IfcLabel-wrapper>SPA</IfcLabel-wrapper>
							<IfcLabel-wrapper>TREATMENT</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="BatterAtEnd_00v9g0qVKHuO00025QrE$V" GlobalId="00v9g0qVKHuO00025QrE$V" Name="BatterAtEnd" Description="The angle, in radians, by which the formwork at the ending face of a piece is to be rotated from the vertical in order to compensate for the rotation of the face that will occur once the piece is stripped from its form, inducing camber due to eccentric prestressing." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="BatterAtStart_3xXr00qVGHuO00025QrE$V" GlobalId="3xXr00qVGHuO00025QrE$V" Name="BatterAtStart" Description="The angle, in radians, by which the formwork at the starting face of a piece is to be rotated from the vertical in order to compensate for the rotation of the face that will occur once the piece is stripped from its form, inducing camber due to eccentric prestressing." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="BatteryChargingType_1gCweXW9v248GPX0vRTL$f" GlobalId="1gCweXW9v248GPX0vRTL$f" Name="BatteryChargingType" Description="Identifies the predefined types of battery charging." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_BatteryChargingType">
						<EnumerationValues>
							<IfcLabel-wrapper>RECHARGEABLE</IfcLabel-wrapper>
							<IfcLabel-wrapper>SINGLECHARGE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="BeamCoolingCapacity_10Iy20qSuHuO00025QrE$V" GlobalId="10Iy20qSuHuO00025QrE$V" Name="BeamCoolingCapacity" Description="Cooling capacity of beam. This excludes cooling capacity of supply air." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="BeamHeatingCapacity_13Hh40qSuHuO00025QrE$V" GlobalId="13Hh40qSuHuO00025QrE$V" Name="BeamHeatingCapacity" Description="Heating capacity of beam. This excludes heating capacity of supply air." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="BearingStrength_0KJTgColX9Se1gcILtKvQM" GlobalId="0KJTgColX9Se1gcILtKvQM" Name="BearingStrength" Description="Defining values: α; defined values: bearing strength of bolt holes, i.e. intrados pressure." TemplateType="p_tablevalue" PrimaryMeasureType="IfcPositivePlaneAngleMeasure" SecondaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="BearingStrength_1i7uUGTIL3uA7MvElqB_Gr" GlobalId="1i7uUGTIL3uA7MvElqB_Gr" Name="BearingStrength" Description="Defining values: α; defined values: bearing strength of bolt holes, i.e. intrados pressure." TemplateType="p_tablevalue" PrimaryMeasureType="IfcPositivePlaneAngleMeasure" SecondaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="BearingStrength_33oSGnU852OgqegzmzS5zH" GlobalId="33oSGnU852OgqegzmzS5zH" Name="BearingStrength" Description="Defining values: α; defined values: bearing strength of bolt holes, i.e. intrados pressure." TemplateType="p_tablevalue" PrimaryMeasureType="IfcPositivePlaneAngleMeasure" SecondaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="BendAngle_3jE3I0qV8HuO00025QrE$V" GlobalId="3jE3I0qV8HuO00025QrE$V" Name="BendAngle" Description="The change of direction of flow." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositivePlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="BendingStrength_0mYnO4_dzB4Rfn5rgnJt$x" GlobalId="0mYnO4_dzB4Rfn5rgnJt$x" Name="BendingStrength" Description="Bending strength." TemplateType="p_tablevalue" PrimaryMeasureType="IfcPressureMeasure" SecondaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="BendingStrength_1mJcyU5FjEvPlHNmb60SjF" GlobalId="1mJcyU5FjEvPlHNmb60SjF" Name="BendingStrength" Description="Bending strength." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="BendingStrength_1oJsaXinL0WvDVCL88_ITB" GlobalId="1oJsaXinL0WvDVCL88_ITB" Name="BendingStrength" Description="Bending strength.

Defining values: α; defined values: bending strength." TemplateType="p_tablevalue" PrimaryMeasureType="IfcPositivePlaneAngleMeasure" SecondaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="BendingStrength_3q0eS9kKL9SvOX70nmAK$A" GlobalId="3q0eS9kKL9SvOX70nmAK$A" Name="BendingStrength" Description="Defining values: α; defined values: bending strength." TemplateType="p_tablevalue" PrimaryMeasureType="IfcPositivePlaneAngleMeasure" SecondaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="BendingStrength_3uAmt8haD0dAvgoiwl5n_m" GlobalId="3uAmt8haD0dAvgoiwl5n_m" Name="BendingStrength" Description="Defining values: α; defined values: bending strength." TemplateType="p_tablevalue" PrimaryMeasureType="IfcPositivePlaneAngleMeasure" SecondaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="BendingStrength_3Y5KkhnojDTerh9JKKXi0W" GlobalId="3Y5KkhnojDTerh9JKKXi0W" Name="BendingStrength" Description="Bending strength." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="BendRadius_3obNy0qV8HuO00025QrE$V" GlobalId="3obNy0qV8HuO00025QrE$V" Name="BendRadius" Description="The radius of bending if circular arc or zero if sharp bend." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="BentSpacing_3luyrgW5f2MfRaz4L28ggQ" GlobalId="3luyrgW5f2MfRaz4L28ggQ" Name="BentSpacing" Description="Bent (upright) spacing" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="BerthApproach_1LqIMaFG1E_wM6$ISDhRBy" GlobalId="1LqIMaFG1E_wM6$ISDhRBy" Name="BerthApproach" Description="How the vessel approaches the berth" TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_BerthApproach">
						<EnumerationValues>
							<IfcLabel-wrapper>SIDE</IfcLabel-wrapper>
							<IfcLabel-wrapper>END</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="BerthCargoWeight_3mukLKUYvFDBZX5V9O8L21" GlobalId="3mukLKUYvFDBZX5V9O8L21" Name="BerthCargoWeight" Description="Total cargo weight of berths within the facility" TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassMeasure" />
				<IfcSimplePropertyTemplate id="BerthGrade_1784IOUnfDrOCPB7_1W7Jl" GlobalId="1784IOUnfDrOCPB7_1W7Jl" Name="BerthGrade" Description="Berth grade" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="BerthingAngle_3y49jAM0H9uwXHrpwZiiI_" GlobalId="3y49jAM0H9uwXHrpwZiiI_" Name="BerthingAngle" Description="Angle of approach for the vessel to the berth" TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="BerthingVelocity_0lfz_btiD35xmqq3NTnBX2" GlobalId="0lfz_btiD35xmqq3NTnBX2" Name="BerthingVelocity" Description="Velocity of the vessel as it berths" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLinearVelocityMeasure" />
				<IfcSimplePropertyTemplate id="BerthMode_0MTZ3yk9jEGRBp1YWiaSMb" GlobalId="0MTZ3yk9jEGRBp1YWiaSMb" Name="BerthMode" Description="Orientation of vessel as it approaches berth" TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_BerthMode">
						<EnumerationValues>
							<IfcLabel-wrapper>BOW</IfcLabel-wrapper>
							<IfcLabel-wrapper>STERN</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Berths_2x4Y1IYYv4$h9BLcWB9gLQ" GlobalId="2x4Y1IYYv4$h9BLcWB9gLQ" Name="Berths" Description="Number of standard berths within the facility" TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="BladeAction_0Mu6G0qT4HuO00025QrE$V" GlobalId="0Mu6G0qT4HuO00025QrE$V" Name="BladeAction" Description="Blade action." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_DamperBladeAction">
						<EnumerationValues>
							<IfcLabel-wrapper>FOLDINGCURTAIN</IfcLabel-wrapper>
							<IfcLabel-wrapper>PARALLEL</IfcLabel-wrapper>
							<IfcLabel-wrapper>OPPOSED</IfcLabel-wrapper>
							<IfcLabel-wrapper>SINGLE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="BladeEdge_0nijY0qT4HuO00025QrE$V" GlobalId="0nijY0qT4HuO00025QrE$V" Name="BladeEdge" Description="Blade edge." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_DamperBladeEdge">
						<EnumerationValues>
							<IfcLabel-wrapper>CRIMPED</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNCRIMPED</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="BladePositionAngle_3CNkU0qT0HuO00025QrE$V" GlobalId="3CNkU0qT0HuO00025QrE$V" Name="BladePositionAngle" Description="Blade position angle; angle between the blade and flow direction ( 0 - 90)." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPositivePlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="BladeRadius_2ofuc3Up1869TEaeM_5Uhn" GlobalId="2ofuc3Up1869TEaeM_5Uhn" Name="BladeRadius" Description="The radius of the blade bend defined as design parameter." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="BladeShape_0bBe00qT4HuO00025QrE$V" GlobalId="0bBe00qT4HuO00025QrE$V" Name="BladeShape" Description="Blade shape. Flat means triple V-groove." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_DamperBladeShape">
						<EnumerationValues>
							<IfcLabel-wrapper>FLAT</IfcLabel-wrapper>
							<IfcLabel-wrapper>FABRICATEDAIRFOIL</IfcLabel-wrapper>
							<IfcLabel-wrapper>EXTRUDEDAIRFOIL</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="BladesOrientation_1$5SWy5mf8nPhe9jueRr_a" GlobalId="1$5SWy5mf8nPhe9jueRr_a" Name="BladesOrientation" Description="Orientation of internal blades." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_BladesOrientation">
						<EnumerationValues>
							<IfcLabel-wrapper>BLADESOUTSIDE</IfcLabel-wrapper>
							<IfcLabel-wrapper>BLADESINSIDE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="BladeThickness_0DxvA0qT4HuO00025QrE$V" GlobalId="0DxvA0qT4HuO00025QrE$V" Name="BladeThickness" Description="The thickness of the damper blade." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="BodyColour_2xkMm0qUOHuO00025QrE$V" GlobalId="2xkMm0qUOHuO00025QrE$V" Name="BodyColour" Description="Colour of the body of the hydrant.

Note: Consult local fire regulations for statutory colours that may be required for hydrant bodies in particular circumstances." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="BodyMass_1FK6G0qWeHuO00025QrE$V" GlobalId="1FK6G0qWeHuO00025QrE$V" Name="BodyMass" Description="Overall body mass of the heater." TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassMeasure" />
				<IfcSimplePropertyTemplate id="BoilingPoint_0Bv$o0qUuHuO00025QrE$V" GlobalId="0Bv$o0qUuHuO00025QrE$V" Name="BoilingPoint" Description="The boiling point of the material (fluid)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="BoltCrossSection_1CDdPMxFj0bw0JOlDAhTgq" GlobalId="1CDdPMxFj0bw0JOlDAhTgq" Name="BoltCrossSection" Description="Type of bolt cross section." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_BoltCrossSection">
						<EnumerationValues>
							<IfcLabel-wrapper>SOLIDBAR</IfcLabel-wrapper>
							<IfcLabel-wrapper>HOLLOWBAR</IfcLabel-wrapper>
							<IfcLabel-wrapper>RIBBED</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
							<IfcLabel-wrapper>USERDEFINED</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="BoltDiameter_2CtNv1HnL2lBA_fBoeeXLD" GlobalId="2CtNv1HnL2lBA_fBoeeXLD" Name="BoltDiameter" Description="Diameter of the bolt. When there is a solid geometry from which the diameter can be derived, the geometric representation takes precedence." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="BoltholePitch_2yL$_0qV8HuO00025QrE$V" GlobalId="2yL$_0qV8HuO00025QrE$V" Name="BoltholePitch" Description="Diameter of the circle along which the boltholes are placed." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="BoltLength_1H5Z$T2YX1fu0c7_lXRSF8" GlobalId="1H5Z$T2YX1fu0c7_lXRSF8" Name="BoltLength" Description="Length of the bolt. When there is a solid geometry from which the length can be derived, the geometric representation takes precedence." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="BoltLength_3qco31$wb0lR1QsW$CJbYv" GlobalId="3qco31$wb0lR1QsW$CJbYv" Name="BoltLength" Description="Length of steel strap mounting bolts." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="BoltSize_2sOXw0qV8HuO00025QrE$V" GlobalId="2sOXw0qV8HuO00025QrE$V" Name="BoltSize" Description="Size of the bolts securing the flange." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="BoltType_0uYUldgMH5mRcvZ37CI2wI" GlobalId="0uYUldgMH5mRcvZ37CI2wI" Name="BoltType" Description="Specifies the type of bolts used for the steel rib." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_BoltType">
						<EnumerationValues>
							<IfcLabel-wrapper>GROUTED</IfcLabel-wrapper>
							<IfcLabel-wrapper>ANCHORED</IfcLabel-wrapper>
							<IfcLabel-wrapper>ANCHOREDWITHEXPANSIONCASING</IfcLabel-wrapper>
							<IfcLabel-wrapper>COMBINATION</IfcLabel-wrapper>
							<IfcLabel-wrapper>FRICTION</IfcLabel-wrapper>
							<IfcLabel-wrapper>FITTING</IfcLabel-wrapper>
							<IfcLabel-wrapper>CABLE</IfcLabel-wrapper>
							<IfcLabel-wrapper>WIRE</IfcLabel-wrapper>
							<IfcLabel-wrapper>SELFDRILLING</IfcLabel-wrapper>
							<IfcLabel-wrapper>GLASSFIBREREINFORCEDPLASTICS</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
							<IfcLabel-wrapper>USERDEFINED</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="BoltType_1hXaGNY9PBI8lNN9k3njm_" GlobalId="1hXaGNY9PBI8lNN9k3njm_" Name="BoltType" Description="Should reuse BoltType in #818" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="BoreholeAzimuth_0gN7ztT89FlOcDscg5dCUo" GlobalId="0gN7ztT89FlOcDscg5dCUo" Name="BoreholeAzimuth" Description="If the drilling is inclined, the horizontal component in the borehole direction is entered based on the 360 degree orientation method moving right from true north." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="BoreholeCount_1DBeislK1CbfTPnPGztE29" GlobalId="1DBeislK1CbfTPnPGztE29" Name="BoreholeCount" Description="Number of boreholes." TemplateType="p_singlevalue" PrimaryMeasureType="IfcInteger" />
				<IfcSimplePropertyTemplate id="BoreholeElevation_0zNwWthFTDjuOnS8GoqDch" GlobalId="0zNwWthFTDjuOnS8GoqDch" Name="BoreholeElevation" Description="If present, the property reports the elevation data in meters for the borehole (i.e., wellbore) start point. This is a compromise approach to allow for delivery of legacy 2D data without elevation data, and for software that cannot process a 3D GM_Point." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="BoreholeFilter_3fE4eMnCT7eveQISamMQlZ" GlobalId="3fE4eMnCT7eveQISamMQlZ" Name="BoreholeFilter" Description="Identification of filter segment installed in the casing of a borehole." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="BoreholeGeophysConfiguration_1LBvY6mqnA6Bh1tDfqA$ws" GlobalId="1LBvY6mqnA6Bh1tDfqA$ws" Name="BoreholeGeophysConfiguration" Description="Configuration of the sources and receivers used in the borehole geophysical surveys." TemplateType="p_listvalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="BoreholeGradient_225RK5rBrEBAwcf$dqwrFh" GlobalId="225RK5rBrEBAwcf$dqwrFh" Name="BoreholeGradient" Description="Angle of borehole to drive direction." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="BoreholeInclination_0DT5srGsL6xA1DS1X9AiCL" GlobalId="0DT5srGsL6xA1DS1X9AiCL" Name="BoreholeInclination" Description="The angle formed by a vertical line and the vertical component in the borehole direction is entered." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="BoreholeInstallation_0o06vNWW901uy$1qJJssW7" GlobalId="0o06vNWW901uy$1qJJssW7" Name="BoreholeInstallation" Description="Equipment installed in the borehole." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="BoreholeLengthDrilled_3Q4N7zz8fFIPA03iGeIzS1" GlobalId="3Q4N7zz8fFIPA03iGeIzS1" Name="BoreholeLengthDrilled" Description="The length of a borehole as drilled and logged, in metres, as determined by the data provider." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="BoreholeLengthPlanned_1_khbjyjf8z9JjevtGbGtr" GlobalId="1_khbjyjf8z9JjevtGbGtr" Name="BoreholeLengthPlanned" Description="The planned length of a borehole e.g. in a site investigation program, in metres, as determined by the data provider." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="BoreholeOverlap_1bTfnQKz18HexhiWS49WG_" GlobalId="1bTfnQKz18HexhiWS49WG_" Name="BoreholeOverlap" Description="Overlap of staggered boreholes." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="BoreHolePurpose_0B_BoCWVj11vkE_OgYOaPd" GlobalId="0B_BoCWVj11vkE_OgYOaPd" Name="BoreHolePurpose" Description="Purpose for which the borehole, section or volumetric model was created. (EU Inspire, boreholeML)" TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_StrataAssemblyPurpose">
						<EnumerationValues>
							<IfcLabel-wrapper>SITE_INVESTIGATION</IfcLabel-wrapper>
							<IfcLabel-wrapper>HYDROCARBON</IfcLabel-wrapper>
							<IfcLabel-wrapper>FEEDSTOCK</IfcLabel-wrapper>
							<IfcLabel-wrapper>MINERAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>GEOLOGICAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>HYDROGEOLOGICAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>DEPOSIT</IfcLabel-wrapper>
							<IfcLabel-wrapper>STORAGE</IfcLabel-wrapper>
							<IfcLabel-wrapper>ENVIRONMENTAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>PEDOLOGICAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>GEOTHERMAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>USERDEFINED</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTDEFINED</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="BoreholePurpose_19nhs50GzAe8WtYEV3BYlH" GlobalId="19nhs50GzAe8WtYEV3BYlH" Name="BoreholePurpose" Description="The purpose property reports the purpose for which the borehole was drilled." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="BoreholeSpacing_3zHZ8zixv0VPAwab6YkHPN" GlobalId="3zHZ8zixv0VPAwab6YkHPN" Name="BoreholeSpacing" Description="Spacing of boreholes used for dewatering." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="BoreholeState_1VopAZOTj308bCkHC7bFi5" GlobalId="1VopAZOTj308bCkHC7bFi5" Name="BoreholeState" Description="The state the borehole or trial pit has been left in. (boreholeML)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_BoreholeStatus">
						<EnumerationValues>
							<IfcLabel-wrapper>CAP_REPLACED</IfcLabel-wrapper>
							<IfcLabel-wrapper>CASING_REPLACED</IfcLabel-wrapper>
							<IfcLabel-wrapper>CASING_PARTIALLY_REPLACED</IfcLabel-wrapper>
							<IfcLabel-wrapper>CASING_INSTALLED</IfcLabel-wrapper>
							<IfcLabel-wrapper>INSTALLED</IfcLabel-wrapper>
							<IfcLabel-wrapper>RECONDITIONED</IfcLabel-wrapper>
							<IfcLabel-wrapper>CHAMBER_RECONDITIONED</IfcLabel-wrapper>
							<IfcLabel-wrapper>DECONSTRUCTED</IfcLabel-wrapper>
							<IfcLabel-wrapper>PARTIALLY_DECONSTRUCTED</IfcLabel-wrapper>
							<IfcLabel-wrapper>REFILLED</IfcLabel-wrapper>
							<IfcLabel-wrapper>PARTIALLY_REFILLED</IfcLabel-wrapper>
							<IfcLabel-wrapper>USERDEFINED</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTDEFINED</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="BoreSize_2QNdq0qV8HuO00025QrE$V" GlobalId="2QNdq0qV8HuO00025QrE$V" Name="BoreSize" Description="The nominal bore of the pipe flange." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="BotanicalName_1wKb_YtzfA_xM$jfazqTfc" GlobalId="1wKb_YtzfA_xM$jfazqTfc" Name="BotanicalName" Description="Formal scientific name conforming to the International Code of Nomenclature for algae, fungi, and plants (ICN)" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="BottomCover_3yRB60qVKHuO00025QrE$V" GlobalId="3yRB60qVKHuO00025QrE$V" Name="BottomCover" Description="Bottom cover of the profile." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="Boulders_3bLi1JRx93T88yfLqjfaa3" GlobalId="3bLi1JRx93T88yfLqjfaa3" Name="Boulders" Description="Description of expected or observed boulders features." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="Boulders_3OFU_v1XvEGvqbexrHXzdz" GlobalId="3OFU_v1XvEGvqbexrHXzdz" Name="Boulders" Description="Description of expected or observed boulders features." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="BouldersVolume_1R39LZPv19iQPBk6DS_nYX" GlobalId="1R39LZPv19iQPBk6DS_nYX" Name="BouldersVolume" Description="Relative volume of boulders (typically larger than 200mm) stratum constituents." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumeMeasure" />
				<IfcSimplePropertyTemplate id="BoundaryAreaHeatLoss_1XVj80qWiHuO00025QrE$V" GlobalId="1XVj80qWiHuO00025QrE$V" Name="BoundaryAreaHeatLoss" Description="Heat loss per unit area for the boundary object. This is a design input value for use in the absence of calculated load data." TemplateType="p_singlevalue" PrimaryMeasureType="IfcHeatFluxDensityMeasure" />
				<IfcSimplePropertyTemplate id="BrakingLength_3S5C4lkGf3_vevKH2HI3L4" GlobalId="3S5C4lkGf3_vevKH2HI3L4" Name="BrakingLength" Description="Length of the braking distance as a design parameter of the bumper occurrence." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="BranchLineDirection_22jf5Fjrb7QQNs0siCGIsQ" GlobalId="22jf5Fjrb7QQNs0siCGIsQ" Name="BranchLineDirection" Description="Describes the direction associated to the branch line of the turnout (deviated branch)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_BranchLineDirection">
						<EnumerationValues>
							<IfcLabel-wrapper>LEFTDEVIATION</IfcLabel-wrapper>
							<IfcLabel-wrapper>RIGHTDEVIATION</IfcLabel-wrapper>
							<IfcLabel-wrapper>SYMETRIC</IfcLabel-wrapper>
							<IfcLabel-wrapper>RIGHT_LEFTDEVIATION</IfcLabel-wrapper>
							<IfcLabel-wrapper>RIGHT_RIGHTDEVIATION</IfcLabel-wrapper>
							<IfcLabel-wrapper>LEFT_LEFTDEVIATION</IfcLabel-wrapper>
							<IfcLabel-wrapper>LEFT_RIGHTDEVIATION</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="BreakdownVoltageTolerance_36oHQCC0b0jubTadGmGjOS" GlobalId="36oHQCC0b0jubTadGmGjOS" Name="BreakdownVoltageTolerance" Description="Nominal value of the spark gap breakdown voltage tolerance." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricVoltageMeasure" />
				<IfcSimplePropertyTemplate id="BreakerUnitCurve_3PZyo0qVWHuO00025QrE$V" GlobalId="3PZyo0qVWHuO00025QrE$V" Name="BreakerUnitCurve" Description="A curve that establishes the let through energy of a breaker unit when a particular prospective current is applied.  Note that the breaker unit curve is defined within a Cartesian coordinate system and this fact must be asserted within the property set:

(1) Defining value: ProspectiveCurrent: A list of minimum 2 and maximum 16 numbers providing the currents in [A] for points in the current/I2t log/log coordinate space. The curve is drawn as a straight line between two consecutive points.
(2) Defined value: LetThroughEnergy: A list of minimum 2 and maximum 16 numbers providing the let-through energy, I2t, in [A2s] for points in the current/I2t log/log coordinate space. The curve is drawn as a straight line between two consecutive points." TemplateType="p_tablevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" SecondaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="BreakerUnitFuseBreakingingCurve_0cSwC0qVaHuO00025QrE$V" GlobalId="0cSwC0qVaHuO00025QrE$V" Name="BreakerUnitFuseBreakingingCurve" Description="A curve that establishes the let through breaking energy of a breaker unit when a particular prospective breaking current is applied.  Note that the breaker unit fuse breaking curve is defined within a Cartesian coordinate system and this fact must be:

(1) Defining value: ProspectiveCurrentBreaking: A list of minimum 2 and maximum 8 numbers providing the currents in [A] for points in the current/breaking energy log/log coordinate space. The curve is drawn as a straight line between two consecutive points.
(2) Defined value: LetThroughBreakingEnergy: A list of minimum 2 and maximum 8 numbers providing the breaking energy whereby the fuse has provided a break, I2t, in [A2s] for points in the current/breakting_energy log/log coordinate space. The curve is drawn as a straight line between two consecutive." TemplateType="p_tablevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" SecondaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="BreakerUnitFuseMeltingCurve_0LAfQ0qVaHuO00025QrE$V" GlobalId="0LAfQ0qVaHuO00025QrE$V" Name="BreakerUnitFuseMeltingCurve" Description="A curve that establishes the energy required to melt the fuse of a breaker unit when a particular prospective melting current is applied.  Note that the breaker unit fuse melting curve is defined within a Cartesian coordinate system and this fact must be:

(1) Defining value: ProspectiveCurrentMelting :A list of minimum 2 and maximum 8 numbers providing the currents in [A] for points in the current/melting_energy log/log coordinate space. The curve is drawn as a straight line between two consecutive points.
(2) Defined value: MeltingEnergy: A list of minimum 2 and maximum 8 numbers providing the energy whereby the fuse is starting to melt, I2t, in [A2s] for points in the current/melting_energy log/log coordinate space. The curve is drawn as a straight line between two consecutive points." TemplateType="p_tablevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" SecondaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="BreakerUnitIPICurve_1e14u0qVaHuO00025QrE$V" GlobalId="1e14u0qVaHuO00025QrE$V" Name="BreakerUnitIPICurve" Description="A curve that establishes the let through peak current of a breaker unit when a particular prospective current is applied.  Note that the breaker unit IPI curve is defined within a Cartesian coordinate system and this fact must be asserted within the property set:

(1) Defining value: A list of minimum 2 and maximum 16 numbers providing the currents in [A] for points in the I/Î log/log coordinate space. The curve is drawn as a straight line between two consecutive points.
(2) Defined value: A list of minimum 2 and maximum 16 numbers providing the let-through peak currents, Î, in [A] for points in the I/Î log/log coordinate space. The curve is drawn as a straight line between two consecutive points." TemplateType="p_tablevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" SecondaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="BreakingCapacity_0SRRZKplf9oAKBz3w0a2po" GlobalId="0SRRZKplf9oAKBz3w0a2po" Name="BreakingCapacity" Description="The current that a fuse, circuit breaker, or other electrical apparatus is able to interrupt without being destroyed or causing an electric arc with unacceptable duration." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="BreechingInletType_19I8m0qUOHuO00025QrE$V" GlobalId="19I8m0qUOHuO00025QrE$V" Name="BreechingInletType" Description="Defines the type of breeching inlet." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_BreechingInletType">
						<EnumerationValues>
							<IfcLabel-wrapper>TWOWAY</IfcLabel-wrapper>
							<IfcLabel-wrapper>FOURWAY</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>USERDEFINED</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTDEFINED</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Brightness_2hZvM0qS8HuO00025QrE$V" GlobalId="2hZvM0qS8HuO00025QrE$V" Name="Brightness" Description="Indicates the display brightness." TemplateType="p_singlevalue" PrimaryMeasureType="IfcIlluminanceMeasure" />
				<IfcSimplePropertyTemplate id="BudgetSource_12TaK0qVSHuO00025QrE$V" GlobalId="12TaK0qVSHuO00025QrE$V" Name="BudgetSource" Description="The budget source requested." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="BuildableArea_3JLHo0qWSHuO00025QrE$V" GlobalId="3JLHo0qWSHuO00025QrE$V" Name="BuildableArea" Description="The area of site utilization expressed as a maximum value according to local building codes." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAreaMeasure" />
				<IfcSimplePropertyTemplate id="BuildingHeightLimit_3Yr6M0qWSHuO00025QrE$V" GlobalId="3Yr6M0qWSHuO00025QrE$V" Name="BuildingHeightLimit" Description="Allowed maximum height of buildings on this site - according to local building codes." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="BuildingID_3rUNi0qSGHuO00025QrE$V" GlobalId="3rUNi0qSGHuO00025QrE$V" Name="BuildingID" Description="A unique identifier assigned to a building. A temporary identifier is initially assigned at the time of making a planning application. This temporary identifier is changed to a permanent identifier when the building is registered into a statutory buildings and properties database." TemplateType="p_singlevalue" PrimaryMeasureType="IfcIdentifier" />
				<IfcSimplePropertyTemplate id="BuildingThermalExposure_0Scd60qV8HuO00025QrE$V" GlobalId="0Scd60qV8HuO00025QrE$V" Name="BuildingThermalExposure" Description="The thermal exposure expected by the building based on surrounding site conditions." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_BuildingThermalExposure">
						<EnumerationValues>
							<IfcLabel-wrapper>LIGHT</IfcLabel-wrapper>
							<IfcLabel-wrapper>MEDIUM</IfcLabel-wrapper>
							<IfcLabel-wrapper>HEAVY</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="BulbLiquidColour_1PhJQ0qUSHuO00025QrE$V" GlobalId="1PhJQ0qUSHuO00025QrE$V" Name="BulbLiquidColour" Description="The colour of the liquid in the bulb for a bulb activated sprinkler. Note that the liquid colour varies according to the activation temperature requirement of the sprinkler head. Note also that this property does not need to be asserted for quick response activated sprinklers." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_SprinklerBulbLiquidColour">
						<EnumerationValues>
							<IfcLabel-wrapper>ORANGE</IfcLabel-wrapper>
							<IfcLabel-wrapper>RED</IfcLabel-wrapper>
							<IfcLabel-wrapper>YELLOW</IfcLabel-wrapper>
							<IfcLabel-wrapper>GREEN</IfcLabel-wrapper>
							<IfcLabel-wrapper>BLUE</IfcLabel-wrapper>
							<IfcLabel-wrapper>MAUVE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="BulkingFactor_3Uxd60AAr21eGcLI8RmIS$" GlobalId="3Uxd60AAr21eGcLI8RmIS$" Name="BulkingFactor" Description="Increase in volume after excavation." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="BumperOrientation_3AhGD6LjPDHuOpWNcMtyWq" GlobalId="3AhGD6LjPDHuOpWNcMtyWq" Name="BumperOrientation" Description="Direction in which the bumper is aligned, e.g. same direction as increasing stationing values or opposite." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_BumperOrientation">
						<EnumerationValues>
							<IfcLabel-wrapper>STATIONDIRECTION</IfcLabel-wrapper>
							<IfcLabel-wrapper>OPPOSITETOSTATIONDIRECTION</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="BypassFactor_0tMF00qSeHuO00025QrE$V" GlobalId="0tMF00qSeHuO00025QrE$V" Name="BypassFactor" Description="Fraction of air that is bypassed by the coil (0-1)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="Ca2_10wmfjd5PB5xuqHQBOdisp" GlobalId="10wmfjd5PB5xuqHQBOdisp" Name="Ca2+" Description="Content of Ca2+ in the water sample." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="CableArmourType_3$2Up8Fxb2RPdKNA2Tyn0M" GlobalId="3$2Up8Fxb2RPdKNA2Tyn0M" Name="CableArmourType" Description="The armour type of the cable for mechanical protection." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_CableArmourType">
						<EnumerationValues>
							<IfcLabel-wrapper>DIELECTRIC</IfcLabel-wrapper>
							<IfcLabel-wrapper>METALLIC</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="CableArrangerPosition_1bt9RJJNv7CeH$s$fdSlY0" GlobalId="1bt9RJJNv7CeH$s$fdSlY0" Name="CableArrangerPosition" Description="Indicates the directional position of the cable arranger: vertical, horizontal, front or rear. It is relative to the element (usually a cabinet) that the cable arranger is affiliated." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ArrangerPositionEnum">
						<EnumerationValues>
							<IfcLabel-wrapper>FRONTSIDE</IfcLabel-wrapper>
							<IfcLabel-wrapper>REARSIDE</IfcLabel-wrapper>
							<IfcLabel-wrapper>HORIZONTAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>VERTICAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="CableDuctOccupancyRatio_3H1ZJK$c58WQOmBVrQdG$S" GlobalId="3H1ZJK$c58WQOmBVrQdG$S" Name="CableDuctOccupancyRatio" Description="Indicates the ratio between the number of cables in the duct and the maximum number of cables that the duct can contain." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="CableFunctionType_185zEg3BX9UPnOrdfFpNFk" GlobalId="185zEg3BX9UPnOrdfFpNFk" Name="CableFunctionType" Description="Distinguishes between Telecom and Power Supply cables." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_CableFunctionType">
						<EnumerationValues>
							<IfcLabel-wrapper>POWERSUPPLY</IfcLabel-wrapper>
							<IfcLabel-wrapper>TELECOMMUNICATION</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="CamberAtMidspan_3smfm0qVGHuO00025QrE$V" GlobalId="3smfm0qVGHuO00025QrE$V" Name="CamberAtMidspan" Description="The camber deflection, measured from the midpoint of a cambered face of a piece to the midpoint of the chord joining the ends of the same face, as shown in the figure below, divided by the original (nominal) straight length of the face of the piece." TemplateType="p_singlevalue" PrimaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="CameraType_3_jHY0qS4HuO00025QrE$V" GlobalId="3_jHY0qS4HuO00025QrE$V" Name="CameraType" Description="Indicates the type of camera." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_AudioVisualCameraType">
						<EnumerationValues>
							<IfcLabel-wrapper>PHOTO</IfcLabel-wrapper>
							<IfcLabel-wrapper>VIDEO</IfcLabel-wrapper>
							<IfcLabel-wrapper>AUDIOVIDEO</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="CantDeficiency_2KWDPEjYP4_PdCs9UElsWA" GlobalId="2KWDPEjYP4_PdCs9UElsWA" Name="CantDeficiency" Description="Difference between applied cant and a higher equilibrium cant." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="CantEquilibrium_30SDceNBr6DB9tffNjbauL" GlobalId="30SDceNBr6DB9tffNjbauL" Name="CantEquilibrium" Description="Cant at a particular speed at which the vehicle will have a resultant force perpendicular to the running plane." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="CantileverType_0XTiJJXGr1wO0ECA2JlUwp" GlobalId="0XTiJJXGr1wO0ECA2JlUwp" Name="CantileverType" Description="Type of cantilever assembly." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_CantileverAssemblyType">
						<EnumerationValues>
							<IfcLabel-wrapper>SINGLE</IfcLabel-wrapper>
							<IfcLabel-wrapper>CENTER_CANTILEVER</IfcLabel-wrapper>
							<IfcLabel-wrapper>DIRECT_SUSPENSION</IfcLabel-wrapper>
							<IfcLabel-wrapper>INSULATED_OVERLAP_CANTILEVER</IfcLabel-wrapper>
							<IfcLabel-wrapper>INSULATED_SUSPENSION_SET</IfcLabel-wrapper>
							<IfcLabel-wrapper>MECHANICAL_OVERLAP_CANTILEVER</IfcLabel-wrapper>
							<IfcLabel-wrapper>MIDPOINT_CANTILEVER</IfcLabel-wrapper>
							<IfcLabel-wrapper>MULTIPLE_TRACK_CANTILEVER</IfcLabel-wrapper>
							<IfcLabel-wrapper>OUT_OF_RUNNING_CANTILEVER</IfcLabel-wrapper>
							<IfcLabel-wrapper>PHASE_SEPARATION_CANTILEVER</IfcLabel-wrapper>
							<IfcLabel-wrapper>SYSTEM_SEPARATION_CANTILEVER</IfcLabel-wrapper>
							<IfcLabel-wrapper>TRANSITION_CANTILEVER</IfcLabel-wrapper>
							<IfcLabel-wrapper>TURNOUT_CANTILEVER</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNDERBRIDGE_CANTILEVER</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Capacitance_05ATmeM_P3vvDHn98$$8$7" GlobalId="05ATmeM_P3vvDHn98$$8$7" Name="Capacitance" Description="Maximum value of the capacitance between the electrodes at specified frequency and temperature." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCapacitanceMeasure" />
				<IfcSimplePropertyTemplate id="Capacity_1Akee0qSyHuO00025QrE$V" GlobalId="1Akee0qSyHuO00025QrE$V" Name="Capacity" Description="The capacity of the element.

Heat transfer rate of the cooling tower between air stream and water stream." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="Capacity_3Otq80qSWHuO00025QrE$V" GlobalId="3Otq80qSWHuO00025QrE$V" Name="Capacity" Description="The capacity of the element.

The product of the ideal capacity and the overall volumetric efficiency of the compressor." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="CapacityControl_2bK_O0qSyHuO00025QrE$V" GlobalId="2bK_O0qSyHuO00025QrE$V" Name="CapacityControl" Description="FanCycling: Fan is cycled on and off to control duty.
TwoSpeedFan: Fan is switched between low and high speed to control duty.
VariableSpeedFan: Fan speed is varied to control duty.
DampersControl: Dampers modulate the air flow to control duty.
BypassValveControl: Bypass valve modulates the water flow to control duty.
MultipleSeriesPumps: Turn on/off multiple series pump to control duty.
TwoSpeedPump: Switch between high/low pump speed to control duty.
VariableSpeedPump: vary pump speed to control duty." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_CoolingTowerCapacityControl">
						<EnumerationValues>
							<IfcLabel-wrapper>FANCYCLING</IfcLabel-wrapper>
							<IfcLabel-wrapper>TWOSPEEDFAN</IfcLabel-wrapper>
							<IfcLabel-wrapper>VARIABLESPEEDFAN</IfcLabel-wrapper>
							<IfcLabel-wrapper>DAMPERSCONTROL</IfcLabel-wrapper>
							<IfcLabel-wrapper>BYPASSVALVECONTROL</IfcLabel-wrapper>
							<IfcLabel-wrapper>MULTIPLESERIESPUMPS</IfcLabel-wrapper>
							<IfcLabel-wrapper>TWOSPEEDPUMP</IfcLabel-wrapper>
							<IfcLabel-wrapper>VARIABLESPEEDPUMP</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="CapacityControlType_1g3_80qUGHuO00025QrE$V" GlobalId="1g3_80qUGHuO00025QrE$V" Name="CapacityControlType" Description="InletVane: Control by adjusting inlet vane.
VariableSpeedDrive: Control by variable speed drive.
BladePitchAngle: Control by adjusting blade pitch angle.
TwoSpeed: Control by switch between high and low speed.
DischargeDamper: Control by modulating discharge damper." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_FanCapacityControlType">
						<EnumerationValues>
							<IfcLabel-wrapper>INLETVANE</IfcLabel-wrapper>
							<IfcLabel-wrapper>VARIABLESPEEDDRIVE</IfcLabel-wrapper>
							<IfcLabel-wrapper>BLADEPITCHANGLE</IfcLabel-wrapper>
							<IfcLabel-wrapper>TWOSPEED</IfcLabel-wrapper>
							<IfcLabel-wrapper>DISCHARGEDAMPER</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="CapacityCurve_0Ud0g0qSaHuO00025QrE$V" GlobalId="0Ud0g0qSaHuO00025QrE$V" Name="CapacityCurve" Description="Chiller cooling capacity is a function of condensing temperature and evaporating temperature, data is in table form, Capacity = f (TempCon, TempEvp), capacity = a1+b1*Tei+c1*Tei\^2+d1*Tci+e1*Tci\^2+f1*Tei*Tci.
This table uses multiple input variables; to represent, both DefiningValues and DefinedValues lists are null and IfcTable is attached using IfcResourceConstraintRelationship and IfcMetric.  Columns are specified in the following order:
1.IfcPowerMeasure:Capacity
2.IfcThermodynamicTemperatureMeasure:CondensingTemperature
3.IfcThermodynamicTemperatureMeasure:EvaporatingTemperature" TemplateType="p_tablevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="CapacityPeople_003Z60qX8HuO00025QrE$V" GlobalId="003Z60qX8HuO00025QrE$V" Name="CapacityPeople" Description="Capacity of the transportation element measured in numbers of person." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="CapacityWeight_05Qtm0qX8HuO00025QrE$V" GlobalId="05Qtm0qX8HuO00025QrE$V" Name="CapacityWeight" Description="Capacity of the transport element measured by weight." TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassMeasure" />
				<IfcSimplePropertyTemplate id="CapColour_30VY00qUOHuO00025QrE$V" GlobalId="30VY00qUOHuO00025QrE$V" Name="CapColour" Description="Colour of the caps of the hydrant.

Note: Consult local fire regulations for statutory colours that may be required for hydrant caps in particular circumstances." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="CapDepth_3Gx94EXhnAxAZUYUNDKUuO" GlobalId="3Gx94EXhnAxAZUYUNDKUuO" Name="CapDepth" Description="Depth of cap (boreholeML)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="CapMaterial_0Ccq_kkRbAMPjW5UXu8hDs" GlobalId="0Ccq_kkRbAMPjW5UXu8hDs" Name="CapMaterial" Description="Cap material or &apos;NOT CAPPED&apos; or &apos;UNKNOWN&apos; (boreholeML)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="CarbonContent_14qw60qUqHuO00025QrE$V" GlobalId="14qw60qUqHuO00025QrE$V" Name="CarbonContent" Description="The carbon content in the fuel. This is measured in weight of carbon per unit weight of fuel and is therefore unitless." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="CarbonDioxideEmissions_0qzq4eq5DDfAgxx_gs$ue9" GlobalId="0qzq4eq5DDfAgxx_gs$ue9" Name="CarbonDioxideEmissions" Description="Rate of emission of carbon dioxide" TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="CargoDeadWeight_2vVxFsGGb3QOAIX9UEyhga" GlobalId="2vVxFsGGb3QOAIX9UEyhga" Name="CargoDeadWeight" Description="Weight of (bulk) cargo carried" TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassMeasure" />
				<IfcSimplePropertyTemplate id="CarrierStackNumber_1waNpZNY9ArOqUXxmsLi6u" GlobalId="1waNpZNY9ArOqUXxmsLi6u" Name="CarrierStackNumber" Description="Number of carrier segments (tray, ladder etc.) that are vertically stacked (vertical is measured as the z-axis of the local coordinate system of the carrier segment)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcInteger" />
				<IfcSimplePropertyTemplate id="CasingDepth_0gmV1hVbn8NwnhNgylps28" GlobalId="0gmV1hVbn8NwnhNgylps28" Name="CasingDepth" Description="Depth of the casing.

For a door, it is the dimension in the plane perpendicular to door leaf. If given it is applied equally to all four sides of the adjacent wall." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="CasingThickness_04ZR14r_9C_vLSphKOkvKo" GlobalId="04ZR14r_9C_vLSphKOkvKo" Name="CasingThickness" Description="Thickness of the casing.

For a door, it is the dimension in plane of the door leaf. If given it is applied equally to all four sides of the adjacent wall." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="CastingMethod_1xR8kP0en6N86AGgIaUR$s" GlobalId="1xR8kP0en6N86AGgIaUR$s" Name="CastingMethod" Description="The method of casting the concrete into its designed form." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ConcreteCastingMethod">
						<EnumerationValues>
							<IfcLabel-wrapper>INSITU</IfcLabel-wrapper>
							<IfcLabel-wrapper>MIXED</IfcLabel-wrapper>
							<IfcLabel-wrapper>PRECAST</IfcLabel-wrapper>
							<IfcLabel-wrapper>PRINTED</IfcLabel-wrapper>
							<IfcLabel-wrapper>SPRAYED_DRY</IfcLabel-wrapper>
							<IfcLabel-wrapper>SPRAYED_WET</IfcLabel-wrapper>
							<IfcLabel-wrapper>SLIPFORMED</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="CatchmentArea_2p1YWircfCd8rNYaGGPhaC" GlobalId="2p1YWircfCd8rNYaGGPhaC" Name="CatchmentArea" Description="Area flowing into sump." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAreaMeasure" />
				<IfcSimplePropertyTemplate id="Category_06lec0qRqHuO00025QrE$V" GlobalId="06lec0qRqHuO00025QrE$V" Name="Category" Description="Designation of the category into which the actors in the population belong." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="CatenaryStayType_0t_MO24RnC$BoGLPbf_Vc7" GlobalId="0t_MO24RnC$BoGLPbf_Vc7" Name="CatenaryStayType" Description="Indicates the type of catenary stay used." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_CatenaryStayType">
						<EnumerationValues>
							<IfcLabel-wrapper>SINGLE_STAY</IfcLabel-wrapper>
							<IfcLabel-wrapper>DOUBLE_STAY</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="CatenaryWireType_33lc5OXGT9FexvS$tyrx03" GlobalId="33lc5OXGT9FexvS$tyrx03" Name="CatenaryWireType" Description="Indicate the type of Catenary wire." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="CdContent_0qniTK$wv25vsXuAYWfca9" GlobalId="0qniTK$wv25vsXuAYWfca9" Name="CdContent" Description="Content of Cadmium. The unit must be defined in _&apos;IfcPropertySingleValue_._Unit&apos;_." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="CeilingCovering_3QWyGZN1r0gwbH3sg_91Bs" GlobalId="3QWyGZN1r0gwbH3sg_91Bs" Name="CeilingCovering" Description="Label to indicate the material or finish of the space ceiling. The label is used for room book information and often displayed in room stamp.The material information is provided in absence of an IfcCovering (type=CEILING) object with own shape representation and material assignment. In case of inconsistency the material assigned to IfcCovering elements takes precedence." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="CeilingCoveringThickness_2hshDd$CPB2B0zM4kkk1d8" GlobalId="2hshDd$CPB2B0zM4kkk1d8" Name="CeilingCoveringThickness" Description="Thickness of the material layer(s) for the space ceiling.The thickness information is provided in absence of an IfcCovering (type=CEILING) object with own shape representation. In cases of inconsistency between the geometric parameters of an assigned IfcCovering and this attached property, the geometric parameters take precedence." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="CeilingRAPlenum_1QLyG0qWiHuO00025QrE$V" GlobalId="1QLyG0qWiHuO00025QrE$V" Name="CeilingRAPlenum" Description="Ceiling plenum used for return air or not. TRUE = Yes, FALSE = No." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="CenterCoreBaseHeight_0sFRW0qVOHuO00025QrE$V" GlobalId="0sFRW0qVOHuO00025QrE$V" Name="CenterCoreBaseHeight" Description="Center core base height of the profile." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="CenterCoreBaseWidth_1Bik80qVOHuO00025QrE$V" GlobalId="1Bik80qVOHuO00025QrE$V" Name="CenterCoreBaseWidth" Description="Center core base width of the profile." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="CenterCoreMiddleHeight_0zPCO0qVOHuO00025QrE$V" GlobalId="0zPCO0qVOHuO00025QrE$V" Name="CenterCoreMiddleHeight" Description="Center core middle height of the profile." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="CenterCoreSpacing_0jvNq0qVOHuO00025QrE$V" GlobalId="0jvNq0qVOHuO00025QrE$V" Name="CenterCoreSpacing" Description="Center core spacing of the profile." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="CenterCoreTopHeight_14YzG0qVOHuO00025QrE$V" GlobalId="14YzG0qVOHuO00025QrE$V" Name="CenterCoreTopHeight" Description="Center core top height of the profile." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="CenterCoreTopWidth_1JSeQ0qVOHuO00025QrE$V" GlobalId="1JSeQ0qVOHuO00025QrE$V" Name="CenterCoreTopWidth" Description="Center core top width of the profile." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="CenterlineAirVelocity_16Xd20qRyHuO00025QrE$V" GlobalId="16Xd20qRyHuO00025QrE$V" Name="CenterlineAirVelocity" Description="Centerline air velocity versus distance from the diffuser and temperature differential; a function of distance from diffuser and temperature difference between supply air and room air." TemplateType="p_tablevalue" PrimaryMeasureType="IfcLinearVelocityMeasure" SecondaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="CentreLineToFairlead_1$AwRqpEfD_9rbUpYn5F65" GlobalId="1$AwRqpEfD_9rbUpYn5F65" Name="CentreLineToFairlead" Description="Distance from the vessel centreline to the fairlead for the line" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="CentreOfGravityInX_2AI9o0qVOHuO00025QrE$V" GlobalId="2AI9o0qVOHuO00025QrE$V" Name="CentreOfGravityInX" Description="Location of the profile&apos;s centre of gravity (geometric centroid), measured along xp." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="CentreOfGravityInY_2I2440qVOHuO00025QrE$V" GlobalId="2I2440qVOHuO00025QrE$V" Name="CentreOfGravityInY" Description="Location of the profile&apos;s centre of gravity (geometric centroid), measured along yp." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="CentroidRadius_2diev9DK90Gvau__QLo_d5" GlobalId="2diev9DK90Gvau__QLo_d5" Name="CentroidRadius" Description="The centroid radius of the element." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ChamberLengthOrRadius_0zKyw0qTGHuO00025QrE$V" GlobalId="0zKyw0qTGHuO00025QrE$V" Name="ChamberLengthOrRadius" Description="Length or, in the event of the shape being circular in plan, the radius of the chamber." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ChamberLengthOrRadius_2JT480qTCHuO00025QrE$V" GlobalId="2JT480qTCHuO00025QrE$V" Name="ChamberLengthOrRadius" Description="Length or, in the event of the shape being circular in plan, the radius of the chamber." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ChamberLengthOrRadius_2M8sS0qTGHuO00025QrE$V" GlobalId="2M8sS0qTGHuO00025QrE$V" Name="ChamberLengthOrRadius" Description="Length or, in the event of the shape being circular in plan, the radius of the chamber." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ChamberWidth_12iHa0qTGHuO00025QrE$V" GlobalId="12iHa0qTGHuO00025QrE$V" Name="ChamberWidth" Description="Width, in the event of the shape being non circular in plan." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ChamberWidth_2OqOo0qTCHuO00025QrE$V" GlobalId="2OqOo0qTCHuO00025QrE$V" Name="ChamberWidth" Description="Width, in the event of the shape being non circular in plan." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ChamberWidth_2S6KW0qTGHuO00025QrE$V" GlobalId="2S6KW0qTGHuO00025QrE$V" Name="ChamberWidth" Description="Width, in the event of the shape being non circular in plan." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="CharacteristicExponent_2zuF80qWaHuO00025QrE$V" GlobalId="2zuF80qWaHuO00025QrE$V" Name="CharacteristicExponent" Description="Characteristic exponent, slope of log(heat output) vs log (surface temperature minus environmental temperature)." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="CharacteristicFunction_3k9Awz48fCZAHkVCckwD67" GlobalId="3k9Awz48fCZAHkVCckwD67" Name="CharacteristicFunction" Description="The characteristic function to show the relationship between varistor current and voltage." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="CharacteristicImpedance_10mgUNnHf1VfAg7w_L3oMi" GlobalId="10mgUNnHf1VfAg7w_L3oMi" Name="CharacteristicImpedance" Description="A quantity defined for a mode of propagation at a given frequency in a specific uniform transmission line or uniform waveguide by one of the three following relations:
Z1 = S/ |I|2
Z2 = |U|2 / S
Z3 = U / I
where Z is the complex characteristic impedance, S the complex power and U and I are the values, usually complex, respectively of a voltage and a current conventionally defined for each type of mode by analogy with transmission line equations" TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricResistanceMeasure" />
				<IfcSimplePropertyTemplate id="ChargePressure_18nEi0qX0HuO00025QrE$V" GlobalId="18nEi0qX0HuO00025QrE$V" Name="ChargePressure" Description="Nominal or design operating pressure of the tank." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="ChargePressure_2YnR20qX0HuO00025QrE$V" GlobalId="2YnR20qX0HuO00025QrE$V" Name="ChargePressure" Description="Nominal or design operating pressure of the tank." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="CheckRailType_2JexmLPDX5sBsONo7e2qsk" GlobalId="2JexmLPDX5sBsONo7e2qsk" Name="CheckRailType" Description="Type of the check rail. Check rail types enumerated in this property are defined based on EN 13674." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_CheckRailType">
						<EnumerationValues>
							<IfcLabel-wrapper>TYPE_33C1</IfcLabel-wrapper>
							<IfcLabel-wrapper>TYPE_40C1</IfcLabel-wrapper>
							<IfcLabel-wrapper>TYPE_47C1</IfcLabel-wrapper>
							<IfcLabel-wrapper>TYPE_CR3_60U</IfcLabel-wrapper>
							<IfcLabel-wrapper>TYPE_R260</IfcLabel-wrapper>
							<IfcLabel-wrapper>TYPE_R320CR</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ChillerCapacity_3_R4k0qSWHuO00025QrE$V" GlobalId="3_R4k0qSWHuO00025QrE$V" Name="ChillerCapacity" Description="Nominal cooling capacity of chiller at standardized conditions as defined by the agency having jurisdiction." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="ChromaticDispersionTolerance_1GC7m4ctzEMR6sRVs2$Rji" GlobalId="1GC7m4ctzEMR6sRVs2$Rji" Name="ChromaticDispersionTolerance" Description="Indicates the tolerance of the transport equipment chromatic dispersion. The value is defined by picosecond per nanometer (ps/nm)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="CillLevelLowerHead_3v8srrGkv5BxHCEgUYjye4" GlobalId="3v8srrGkv5BxHCEgUYjye4" Name="CillLevelLowerHead" Description="Height of the lower head cill level" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="CillLevelUpperHead_3K32apJvH1uOfG1IRMzQCs" GlobalId="3K32apJvH1uOfG1IRMzQCs" Name="CillLevelUpperHead" Description="Height of the upper head cill level" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="CircuitType_1x0YY0qSyHuO00025QrE$V" GlobalId="1x0YY0qSyHuO00025QrE$V" Name="CircuitType" Description="OpenCircuit: Exposes water directly to the cooling atmosphere.
CloseCircuit: The fluid is separated from the atmosphere by a heat exchanger.
Wet: The air stream or the heat exchange surface is evaporatively cooled.
Dry: No evaporation into the air stream.
DryWet: A combination of a dry tower and a wet tower." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_CoolingTowerCircuitType">
						<EnumerationValues>
							<IfcLabel-wrapper>OPENCIRCUIT</IfcLabel-wrapper>
							<IfcLabel-wrapper>CLOSEDCIRCUITWET</IfcLabel-wrapper>
							<IfcLabel-wrapper>CLOSEDCIRCUITDRY</IfcLabel-wrapper>
							<IfcLabel-wrapper>CLOSEDCIRCUITDRYWET</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="CisternCapacity_1uRFQ0qW8HuO00025QrE$V" GlobalId="1uRFQ0qW8HuO00025QrE$V" Name="CisternCapacity" Description="Volumetric capacity of the cistern" TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumeMeasure" />
				<IfcSimplePropertyTemplate id="CisternHeight_1g7jg0qW8HuO00025QrE$V" GlobalId="1g7jg0qW8HuO00025QrE$V" Name="CisternHeight" Description="Enumeration that identifies the height of the cistern or, if set to &apos;None&apos; if the urinal has no cistern and is flushed using mains or high pressure water through a flushing valve." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_CisternHeight">
						<EnumerationValues>
							<IfcLabel-wrapper>HIGHLEVEL</IfcLabel-wrapper>
							<IfcLabel-wrapper>LOWLEVEL</IfcLabel-wrapper>
							<IfcLabel-wrapper>NONE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Cl_1AyulzLmb7kh4MInlhCAEO" GlobalId="1AyulzLmb7kh4MInlhCAEO" Name="Cl-" Description="Content of Cl- in the water sample." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="ClassificationAuthority_0GzNs0qUSHuO00025QrE$V" GlobalId="0GzNs0qUSHuO00025QrE$V" Name="ClassificationAuthority" Description="The name of the authority that applies the classification of service to the hose reel (e.g. NFPA/FEMA)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ClassOfService_09DTa0qUSHuO00025QrE$V" GlobalId="09DTa0qUSHuO00025QrE$V" Name="ClassOfService" Description="A classification of usage of the hose reel that may be applied." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ClayVolume_1ELNjzhfv7fO4ST_8v15TT" GlobalId="1ELNjzhfv7fO4ST_8v15TT" Name="ClayVolume" Description="Relative volume of clay (typically smaller than 0.002mm) stratum constituents." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumeMeasure" />
				<IfcSimplePropertyTemplate id="ClearDepth_0fnrY0qX8HuO00025QrE$V" GlobalId="0fnrY0qX8HuO00025QrE$V" Name="ClearDepth" Description="The clear depth.

It indicates the distance from the inner surface of the elevator door to the opposite surface of the elevator car." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ClearDepth_1ueSs0qTCHuO00025QrE$V" GlobalId="1ueSs0qTCHuO00025QrE$V" Name="ClearDepth" Description="The clear depth.

It indicates the formed space in the duct." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ClearDepth_2ZIr20qUeHuO00025QrE$V" GlobalId="2ZIr20qUeHuO00025QrE$V" Name="ClearDepth" Description="The clear depth.

It indicates the unobstructed depth available for cable inclusion within the junction box." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ClearDepth_3Yocg0qVCHuO00025QrE$V" GlobalId="3Yocg0qVCHuO00025QrE$V" Name="ClearDepth" Description="The clear depth." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ClearHeight_0o7vE0qX8HuO00025QrE$V" GlobalId="0o7vE0qX8HuO00025QrE$V" Name="ClearHeight" Description="Clear height of the object (elevator).
The shape information is provided in addition to the shape representation and the geometric parameters used within. In cases of inconsistency between the geometric parameters and the shape properties, provided in the attached property, the geometric parameters take precedence." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ClearWidth_0WreS0qX8HuO00025QrE$V" GlobalId="0WreS0qX8HuO00025QrE$V" Name="ClearWidth" Description="The clear width.

It indicates the distance from the inner surfaces of the elevator car left and right from the elevator door" TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ClearWidth_1pH8C0qTCHuO00025QrE$V" GlobalId="1pH8C0qTCHuO00025QrE$V" Name="ClearWidth" Description="The clear width.

It indicates the formed space in the duct." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ClearWidth_2BofA0qVyHuO00025QrE$V" GlobalId="2BofA0qVyHuO00025QrE$V" Name="ClearWidth" Description="The clear width.

Measured as the clear space for accessibility and egress; it is a measured distance between the two handrails or the wall and a handrail on a ramp." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ClimateChange_0QC1k0qU8HuO00025QrE$V" GlobalId="0QC1k0qU8HuO00025QrE$V" Name="ClimateChange" Description="Quantity of greenhouse gases emitted calculated in equivalent CO2." TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassMeasure" />
				<IfcSimplePropertyTemplate id="ClimateChangePerUnit_33AaQ0qU4HuO00025QrE$V" GlobalId="33AaQ0qU4HuO00025QrE$V" Name="ClimateChangePerUnit" Description="Quantity of greenhouse gases emitted calculated in equivalent CO2" TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassMeasure" />
				<IfcSimplePropertyTemplate id="CloggingIndicator_0guf20qUOHuO00025QrE$V" GlobalId="0guf20qUOHuO00025QrE$V" Name="CloggingIndicator" Description="Whether the filter has an indicator to display the degree of clogging of the filter." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="CloggingPotential_15oxfkdunAHQ0G5Q2ybvfa" GlobalId="15oxfkdunAHQ0G5Q2ybvfa" Name="CloggingPotential" Description="Description or rating of the potential for clogging equipment in sticky ground." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="CloseOffRating_2ALvK0qXGHuO00025QrE$V" GlobalId="2ALvK0qXGHuO00025QrE$V" Name="CloseOffRating" Description="Close off rating." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="CloseOffRating_2Oq8q0qT4HuO00025QrE$V" GlobalId="2Oq8q0qT4HuO00025QrE$V" Name="CloseOffRating" Description="Close off rating." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="ClosureRatingEnum_3962k0qT4HuO00025QrE$V" GlobalId="3962k0qT4HuO00025QrE$V" Name="ClosureRatingEnum" Description="Enumeration that identifies the closure rating for the damper." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" id="i467" Name="PEnum_FireDamperClosureRating">
						<EnumerationValues>
							<IfcLabel-wrapper>DYNAMIC</IfcLabel-wrapper>
							<IfcLabel-wrapper>STATIC</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ClosureRatingEnum_3waFS0qT4HuO00025QrE$V" GlobalId="3waFS0qT4HuO00025QrE$V" Name="ClosureRatingEnum" Description="Enumeration that identifies the closure rating for the damper." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i467" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="CO2Content_37g2o0qUmHuO00025QrE$V" GlobalId="37g2o0qUmHuO00025QrE$V" Name="CO2Content" Description="Carbon dioxide (CO2) content of the products of combustion. This is measured in weight of CO2 per unit weight and is therefore unitless." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="CobblesVolume_3EnkiYvo91k92LY_eT$sR1" GlobalId="3EnkiYvo91k92LY_eT$sR1" Name="CobblesVolume" Description="Relative volume of cobbles (typically larger than 63mm) stratum constituents." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumeMeasure" />
				<IfcSimplePropertyTemplate id="COContent_31iak0qUmHuO00025QrE$V" GlobalId="31iak0qUmHuO00025QrE$V" Name="COContent" Description="Carbon monoxide (CO) content of the products of combustion. This is measured in weight of CO per unit weight and is therefore unitless." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="CoefficientOfFriction_2NklEn94fAAffIQBYsYnZD" GlobalId="2NklEn94fAAffIQBYsYnZD" Name="CoefficientOfFriction" Description="Coefficient of friction value for the fender" TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="CoefficientOfPerformance_3W1b00qSWHuO00025QrE$V" GlobalId="3W1b00qSWHuO00025QrE$V" Name="CoefficientOfPerformance" Description="The Coefficient of performance (COP) is the ratio of heat removed to energy input.
The energy input may be obtained by multiplying
Pset_DistributionPortPHistoryGas.FlowRate on the &apos;Fuel&apos; port of the IfcChiller by Pset_MaterialFuel.LowerHeatingValue.
The IfcDistributionPort for fuel has an associated IfcMaterial with fuel properties and is assigned to an IfcPerformanceHistory object nested within this IfcPerformanceHistory object." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="CoefficientOfPerformanceCurve_0dZDm0qSaHuO00025QrE$V" GlobalId="0dZDm0qSaHuO00025QrE$V" Name="CoefficientOfPerformanceCurve" Description="Chiller coefficient of performance (COP) is function of condensing temperature and evaporating temperature, data is in table form, COP= f (TempCon, TempEvp), COP = a2+b2*Tei+c2*Tei\^2+d2*Tci+e2*Tci\^2+f2*Tei*Tci.
This table uses multiple input variables; to represent, both DefiningValues and DefinedValues lists are null and IfcTable is attached using IfcResourceConstraintRelationship and IfcMetric.  Columns are specified in the following order:
1.IfcPositiveRatioMeasure:CoefficientOfPerformance
2.IfcThermodynamicTemperatureMeasure:CondensingTemperature
3.IfcThermodynamicTemperatureMeasure:EvaporatingTemperature" TemplateType="p_tablevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" SecondaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="Cohesion_0TtDZk$qPAvwTsHe72Iikw" GlobalId="0TtDZk$qPAvwTsHe72Iikw" Name="Cohesion" Description="Cohesive shear strength of a rock or soil that is independent of interparticle friction." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="CohesionBehaviour_1Ts3cC4K527A$xCe0PeqiV" GlobalId="1Ts3cC4K527A$xCe0PeqiV" Name="CohesionBehaviour" Description="Cohesive shear strength of a rock or soil that is independent of interparticle friction." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="CoilConnectionDirection_3keJS0qSaHuO00025QrE$V" GlobalId="3keJS0qSaHuO00025QrE$V" Name="CoilConnectionDirection" Description="Coil connection direction (facing into the air stream)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_CoilConnectionDirection">
						<EnumerationValues>
							<IfcLabel-wrapper>LEFT</IfcLabel-wrapper>
							<IfcLabel-wrapper>RIGHT</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="CoilCoolant_3XX4W0qSaHuO00025QrE$V" GlobalId="3XX4W0qSaHuO00025QrE$V" Name="CoilCoolant" Description="The fluid used for heating or cooling used by the hydronic coil." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_CoilCoolant">
						<EnumerationValues>
							<IfcLabel-wrapper>WATER</IfcLabel-wrapper>
							<IfcLabel-wrapper>BRINE</IfcLabel-wrapper>
							<IfcLabel-wrapper>GLYCOL</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="CoilFaceArea_0BFMy0qSeHuO00025QrE$V" GlobalId="0BFMy0qSeHuO00025QrE$V" Name="CoilFaceArea" Description="Coil face area in the direction against air the flow." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAreaMeasure" />
				<IfcSimplePropertyTemplate id="CoilFluidArrangement_3zX_c0qSaHuO00025QrE$V" GlobalId="3zX_c0qSaHuO00025QrE$V" Name="CoilFluidArrangement" Description="Fluid flow arrangement of the coil.CrossCounterFlow: Air and water flow enter in different directions.
CrossFlow: Air and water flow are perpendicular.
CrossParallelFlow: Air and water flow enter in same directions." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_CoilFluidArrangement">
						<EnumerationValues>
							<IfcLabel-wrapper>CROSSFLOW</IfcLabel-wrapper>
							<IfcLabel-wrapper>CROSSCOUNTERFLOW</IfcLabel-wrapper>
							<IfcLabel-wrapper>CROSSPARALLELFLOW</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="CoilLength_0w2XG0qSyHuO00025QrE$V" GlobalId="0w2XG0qSyHuO00025QrE$V" Name="CoilLength" Description="Length of coil." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="CoilPlacement_39hCG0qSaHuO00025QrE$V" GlobalId="39hCG0qSaHuO00025QrE$V" Name="CoilPlacement" Description="Indicates the placement of the coil.
FLOOR indicates an under floor heater (if coil type is WATERHEATINGCOIL or ELECTRICHEATINGCOIL);
CEILING indicates a cooling ceiling (if coil type is WATERCOOLINGCOIL);
UNIT indicates that the coil is part of a cooling or heating unit, like cooled beam, etc." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_CoilPlacementType">
						<EnumerationValues>
							<IfcLabel-wrapper>FLOOR</IfcLabel-wrapper>
							<IfcLabel-wrapper>CEILING</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNIT</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="CoilPosition_3WO1I0qUCHuO00025QrE$V" GlobalId="3WO1I0qUCHuO00025QrE$V" Name="CoilPosition" Description="Defines the relationship between a fan and a coil.
DrawThrough: Fan located downstream of the coil.
BlowThrough: Fan located upstream of the coil." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_FanCoilPosition">
						<EnumerationValues>
							<IfcLabel-wrapper>DRAWTHROUGH</IfcLabel-wrapper>
							<IfcLabel-wrapper>BLOWTHROUGH</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="CoilWidth_0_piW0qSyHuO00025QrE$V" GlobalId="0_piW0qSyHuO00025QrE$V" Name="CoilWidth" Description="Width of coil." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="Colour_2J4I2LAOv4qfhgUPNOBh82" GlobalId="2J4I2LAOv4qfhgUPNOBh82" Name="Colour" Description="Colour of this object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="Colour_3G0sO0qV8HuO00025QrE$V" GlobalId="3G0sO0qV8HuO00025QrE$V" Name="Colour" Description="Colour of this object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="Colour_3h5wi0qTqHuO00025QrE$V" GlobalId="3h5wi0qTqHuO00025QrE$V" Name="Colour" Description="Colour of this object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ColourAppearance_11rx60qUiHuO00025QrE$V" GlobalId="11rx60qUiHuO00025QrE$V" Name="ColourAppearance" Description="In both the DIN and CIE standards, artificial light sources are classified in terms of their colour appearance. To the human eye they all appear to be white; the difference can only be detected by direct comparison. Visual performance is not directly affected by differences in colour appearance." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ColourCode_37d3A0qTGHuO00025QrE$V" GlobalId="37d3A0qTGHuO00025QrE$V" Name="ColourCode" Description="Name of a colour for identifying the connector, if applicable." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ColourRenderingIndex_1VfHQ0qUiHuO00025QrE$V" GlobalId="1VfHQ0qUiHuO00025QrE$V" Name="ColourRenderingIndex" Description="The CRI indicates how well a light source renders eight standard colours compared to perfect reference lamp with the same colour temperature. The CRI scale ranges from 1 to 100, with 100 representing perfect rendering properties." TemplateType="p_singlevalue" PrimaryMeasureType="IfcInteger" />
				<IfcSimplePropertyTemplate id="ColourTemperature_1PhpM0qUiHuO00025QrE$V" GlobalId="1PhpM0qUiHuO00025QrE$V" Name="ColourTemperature" Description="The colour temperature of any source of radiation is defined as the temperature (in Kelvin) of a black-body or Planckian radiator whose radiation has the same chromaticity as the source of radiation. Often the values are only approximate colour temperatures as the black-body radiator cannot emit radiation of every chromaticity value. The colour temperatures of the commonest artificial light sources range from less than 3000K (warm white) to 4000K (intermediate) and over 5000K (daylight)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="ColumnShoeBasePlateDepth_0mpdQ0qT8HuO00025QrE$V" GlobalId="0mpdQ0qT8HuO00025QrE$V" Name="ColumnShoeBasePlateDepth" Description="The depth of the column shoe base plate." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ColumnShoeBasePlateThickness_0c4_60qT8HuO00025QrE$V" GlobalId="0c4_60qT8HuO00025QrE$V" Name="ColumnShoeBasePlateThickness" Description="The thickness of the column shoe base plate." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ColumnShoeBasePlateWidth_0i2SA0qT8HuO00025QrE$V" GlobalId="0i2SA0qT8HuO00025QrE$V" Name="ColumnShoeBasePlateWidth" Description="The width of the column shoe base plate." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ColumnShoeCasingDepth_10JR_0qT8HuO00025QrE$V" GlobalId="10JR_0qT8HuO00025QrE$V" Name="ColumnShoeCasingDepth" Description="The depth of the column shoe casing." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ColumnShoeCasingHeight_0sAy40qT8HuO00025QrE$V" GlobalId="0sAy40qT8HuO00025QrE$V" Name="ColumnShoeCasingHeight" Description="The height of the column shoe casing." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ColumnShoeCasingWidth_0wy7K0qT8HuO00025QrE$V" GlobalId="0wy7K0qT8HuO00025QrE$V" Name="ColumnShoeCasingWidth" Description="The width of the column shoe casing." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="CombinedKerbGutter_2XVviYqS9BKeFimfQfNm7U" GlobalId="2XVviYqS9BKeFimfQfNm7U" Name="CombinedKerbGutter" Description="Indicating  the use of a combined kerb and gutter." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="Combustible_0QGn80qWWHuO00025QrE$V" GlobalId="0QGn80qWWHuO00025QrE$V" Name="Combustible" Description="Indication whether the object is made from combustible material (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="Combustible_15gWg0qT0HuO00025QrE$V" GlobalId="15gWg0qT0HuO00025QrE$V" Name="Combustible" Description="Indication whether the object is made from combustible material (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="Combustible_2MkVw0qT0HuO00025QrE$V" GlobalId="2MkVw0qT0HuO00025QrE$V" Name="Combustible" Description="Indication whether the object is made from combustible material (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="Combustible_3Fo980qXKHuO00025QrE$V" GlobalId="3Fo980qXKHuO00025QrE$V" Name="Combustible" Description="Indication whether the object is made from combustible material (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="CombustionChamberTemperature_1Gzpa0qSGHuO00025QrE$V" GlobalId="1Gzpa0qSGHuO00025QrE$V" Name="CombustionChamberTemperature" Description="Average combustion chamber temperature." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="CombustionEfficiency_1AQC60qSGHuO00025QrE$V" GlobalId="1AQC60qSGHuO00025QrE$V" Name="CombustionEfficiency" Description="Combustion efficiency under nominal condition." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="CombustionTemperature_0_tS20qUqHuO00025QrE$V" GlobalId="0_tS20qUqHuO00025QrE$V" Name="CombustionTemperature" Description="Combustion temperature.

Combustion temperature of the material when air is at 298 K and 100 kPa." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="CommencementDate_1kHVg0qVWHuO00025QrE$V" GlobalId="1kHVg0qVWHuO00025QrE$V" Name="CommencementDate" Description="Date on which the agreement commences." TemplateType="p_singlevalue" PrimaryMeasureType="IfcDate" />
				<IfcSimplePropertyTemplate id="CommonInterfaceType_3Xuwkh7UD9wuLX4uBTrvQ8" GlobalId="3Xuwkh7UD9wuLX4uBTrvQ8" Name="CommonInterfaceType" Description="Indicates the type of the device common interfaces." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_CommonInterfaceType">
						<EnumerationValues>
							<IfcLabel-wrapper>DRYCONTACTSINTERFACE</IfcLabel-wrapper>
							<IfcLabel-wrapper>MANAGEMENTINTERFACE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER_IO_INTERFACE</IfcLabel-wrapper>
							<IfcLabel-wrapper>SYNCHRONIZATIONINTERFACE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="CommunicationStandard_23pIPVZq9A19s2K0Qc6rmz" GlobalId="23pIPVZq9A19s2K0Qc6rmz" Name="CommunicationStandard" Description="Indicates the communication standard supported by the physical wired communication port." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_CommunicationStandard">
						<EnumerationValues>
							<IfcLabel-wrapper>ETHERNET</IfcLabel-wrapper>
							<IfcLabel-wrapper>STM_1</IfcLabel-wrapper>
							<IfcLabel-wrapper>STM_16</IfcLabel-wrapper>
							<IfcLabel-wrapper>STM_256</IfcLabel-wrapper>
							<IfcLabel-wrapper>STM_4</IfcLabel-wrapper>
							<IfcLabel-wrapper>STM_64</IfcLabel-wrapper>
							<IfcLabel-wrapper>USB</IfcLabel-wrapper>
							<IfcLabel-wrapper>XDSL</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="CompactionFactor_3IBdqSmXf1vwj5iylqG2hi" GlobalId="3IBdqSmXf1vwj5iylqG2hi" Name="CompactionFactor" Description="Reduction in volume on compaction." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="CompactionMethod_2_UiNQRvH2uuEFFaxMk1It" GlobalId="2_UiNQRvH2uuEFFaxMk1It" Name="CompactionMethod" Description="Method of compaction." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_CompactionMethod">
						<EnumerationValues>
							<IfcLabel-wrapper>ROLLER</IfcLabel-wrapper>
							<IfcLabel-wrapper>TAMPING</IfcLabel-wrapper>
							<IfcLabel-wrapper>NONE</IfcLabel-wrapper>
							<IfcLabel-wrapper>USERDEFINED</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="CompactionMethodOther_3TT9O2$zXCkB7l$kFVljGC" GlobalId="3TT9O2$zXCkB7l$kFVljGC" Name="CompactionMethodOther" Description="User defined method of compaction when CompactionMethod = USERDEFINED." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="Compartmentation_11cTy0qWWHuO00025QrE$V" GlobalId="11cTy0qWWHuO00025QrE$V" Name="Compartmentation" Description="Indication whether the object is designed to serve as a fire compartmentation (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="Compartmentation_3vWRa0qXKHuO00025QrE$V" GlobalId="3vWRa0qXKHuO00025QrE$V" Name="Compartmentation" Description="Indication whether the object is designed to serve as a fire compartmentation (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="Complementaryfunction_0NZNNBTeH4$RmON2XH6spL" GlobalId="0NZNNBTeH4$RmON2XH6spL" Name="Complementaryfunction" Description="Indicates the complementary function of the drain channel." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ComplementaryWorks">
						<EnumerationValues>
							<IfcLabel-wrapper>TRANSVERSAL_WATER_REMOVAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>LIFTING_WATER_WELLS</IfcLabel-wrapper>
							<IfcLabel-wrapper>DISPERSING_WELLS</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTDEFINED</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="CompositeFractions_3vTKU5hpb51Qve8ObZwhUJ" GlobalId="3vTKU5hpb51Qve8ObZwhUJ" Name="CompositeFractions" Description="Denomination into soil groups by composite fractions" TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_SoilCompositeFractions">
						<EnumerationValues>
							<IfcLabel-wrapper>BOULDERS</IfcLabel-wrapper>
							<IfcLabel-wrapper>BOULDERS_WITH_COBBLES</IfcLabel-wrapper>
							<IfcLabel-wrapper>BOULDERS_WITH_FINER_SOILS</IfcLabel-wrapper>
							<IfcLabel-wrapper>GRAVEL_WITH_COBBLES</IfcLabel-wrapper>
							<IfcLabel-wrapper>GRAVEL</IfcLabel-wrapper>
							<IfcLabel-wrapper>SANDY_GRAVEL_WITH_COBBLES</IfcLabel-wrapper>
							<IfcLabel-wrapper>SANDY_GRAVEL</IfcLabel-wrapper>
							<IfcLabel-wrapper>GRAVEL_WITH_CLAY_OR_SILT</IfcLabel-wrapper>
							<IfcLabel-wrapper>GRAVELLY_SAND</IfcLabel-wrapper>
							<IfcLabel-wrapper>SAND</IfcLabel-wrapper>
							<IfcLabel-wrapper>SAND_WITH_CLAY_AND_SILT</IfcLabel-wrapper>
							<IfcLabel-wrapper>SANDY_SILT</IfcLabel-wrapper>
							<IfcLabel-wrapper>SANDY_GRAVELLY_SILT</IfcLabel-wrapper>
							<IfcLabel-wrapper>SANDY_CLAYEY_SILT</IfcLabel-wrapper>
							<IfcLabel-wrapper>CLAYEY_SILT</IfcLabel-wrapper>
							<IfcLabel-wrapper>SILTY_CLAY</IfcLabel-wrapper>
							<IfcLabel-wrapper>SANDY_GRAVELLY_CLAY</IfcLabel-wrapper>
							<IfcLabel-wrapper>SILT</IfcLabel-wrapper>
							<IfcLabel-wrapper>CLAY</IfcLabel-wrapper>
							<IfcLabel-wrapper>ORGANIC_SILT</IfcLabel-wrapper>
							<IfcLabel-wrapper>ORGANIC_CLAY</IfcLabel-wrapper>
							<IfcLabel-wrapper>SANDY_PEAT</IfcLabel-wrapper>
							<IfcLabel-wrapper>FILL</IfcLabel-wrapper>
							<IfcLabel-wrapper>COBBLES</IfcLabel-wrapper>
							<IfcLabel-wrapper>COBBLES_WITH_BOULDERS</IfcLabel-wrapper>
							<IfcLabel-wrapper>COBBLES_WITH_FINER_SOILS</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="CompressedAirFilterType_0CV9K0qUOHuO00025QrE$V" GlobalId="0CV9K0qUOHuO00025QrE$V" Name="CompressedAirFilterType" Description="ACTIVATEDCARBON: absorbs oil vapor and odor; PARTICLE_FILTER: used to absorb solid particles of medium size; COALESCENSE_FILTER: used to absorb fine solid, oil, and water particles, also called micro filter" TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_CompressedAirFilterType">
						<EnumerationValues>
							<IfcLabel-wrapper>ACTIVATEDCARBON</IfcLabel-wrapper>
							<IfcLabel-wrapper>PARTICLE_FILTER</IfcLabel-wrapper>
							<IfcLabel-wrapper>COALESCENSE_FILTER</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="CompressionEfficiency_3dBbs0qSeHuO00025QrE$V" GlobalId="3dBbs0qSeHuO00025QrE$V" Name="CompressionEfficiency" Description="Ratio of the work required for isentropic compression of the gas to the work delivered to the gas within the compression volume (as obtained by measurement)." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="CompressionIndex_1kCf5Yyzb0mg8elIJgHtFu" GlobalId="1kCf5Yyzb0mg8elIJgHtFu" Name="CompressionIndex" Description="Compression index is determined with the oedometer tests, and used to compute settlements." TemplateType="p_singlevalue" PrimaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="CompressiveStrength_0gx8OSAsfDaR6Lagjl0obi" GlobalId="0gx8OSAsfDaR6Lagjl0obi" Name="CompressiveStrength" Description="The compressive strength of the object or material.

Defining values: α; defined values: compressive strength." TemplateType="p_tablevalue" PrimaryMeasureType="IfcPositivePlaneAngleMeasure" SecondaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="CompressiveStrength_13o_PQZLnATfkOJGsX$sGN" GlobalId="13o_PQZLnATfkOJGsX$sGN" Name="CompressiveStrength" Description="Defining values: α; defined values: compressive strength." TemplateType="p_tablevalue" PrimaryMeasureType="IfcPositivePlaneAngleMeasure" SecondaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="CompressiveStrength_2chwSa9R98gR_aQspFjpC6" GlobalId="2chwSa9R98gR_aQspFjpC6" Name="CompressiveStrength" Description="Defining values: α; defined values: compressive strength." TemplateType="p_tablevalue" PrimaryMeasureType="IfcPositivePlaneAngleMeasure" SecondaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="CompressiveStrength_3gEaM0qUmHuO00025QrE$V" GlobalId="3gEaM0qUmHuO00025QrE$V" Name="CompressiveStrength" Description="The compressive strength of the object or material." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="CompressiveStrength24h_3zFO54k7zE$hbebMKr9wo_" GlobalId="3zFO54k7zE$hbebMKr9wo_" Name="CompressiveStrength24h" Description="Compressive strength of the concrete at 24h." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="CompressiveStrength48h_2wVaHRlavFw8VGNtRRpVJa" GlobalId="2wVaHRlavFw8VGNtRRpVJa" Name="CompressiveStrength48h" Description="Compressive strength of the concrete at 48h." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="CompressorCapacity_3Q4Mw0qSeHuO00025QrE$V" GlobalId="3Q4Mw0qSeHuO00025QrE$V" Name="CompressorCapacity" Description="The product of the ideal capacity and the overall volumetric efficiency of the compressor." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="CompressorCondenserHeatGain_1w6yU0qSmHuO00025QrE$V" GlobalId="1w6yU0qSmHuO00025QrE$V" Name="CompressorCondenserHeatGain" Description="Heat gain between condenser inlet to compressor outlet." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="CompressorCondenserPressureDrop_1zhqw0qSmHuO00025QrE$V" GlobalId="1zhqw0qSmHuO00025QrE$V" Name="CompressorCondenserPressureDrop" Description="Pressure drop between condenser inlet and compressor outlet." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="CompressorEvaporatorHeatGain_3k_Vm0qU8HuO00025QrE$V" GlobalId="3k_Vm0qU8HuO00025QrE$V" Name="CompressorEvaporatorHeatGain" Description="Heat gain between the evaporator outlet and the compressor inlet." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="CompressorEvaporatorPressureDrop_3plh00qU8HuO00025QrE$V" GlobalId="3plh00qU8HuO00025QrE$V" Name="CompressorEvaporatorPressureDrop" Description="Pressure drop between the evaporator outlet and the compressor inlet." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="CompressorSpeed_1NrNe0qSiHuO00025QrE$V" GlobalId="1NrNe0qSiHuO00025QrE$V" Name="CompressorSpeed" Description="Compressor speed." TemplateType="p_singlevalue" PrimaryMeasureType="IfcRotationalFrequencyMeasure" />
				<IfcSimplePropertyTemplate id="CompressorTotalEfficiency_3mjyM0qSeHuO00025QrE$V" GlobalId="3mjyM0qSeHuO00025QrE$V" Name="CompressorTotalEfficiency" Description="Ratio of the thermal cooling capacity to electrical input." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="CompressorTotalHeatGain_020D80qSiHuO00025QrE$V" GlobalId="020D80qSiHuO00025QrE$V" Name="CompressorTotalHeatGain" Description="Compressor total heat gain." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="CompStrength_0KKYZceoj1zOtGz8I7XmVq" GlobalId="0KKYZceoj1zOtGz8I7XmVq" Name="CompStrength" Description="Compressive strength, α=0°." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="CompStrength_0N455YE$f0Q9gp2KsnM8YB" GlobalId="0N455YE$f0Q9gp2KsnM8YB" Name="CompStrength" Description="Compressive strength, α=0°." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="CompStrength_3VTMcUo6XCeAAYmM_MZLrH" GlobalId="3VTMcUo6XCeAAYmM_MZLrH" Name="CompStrength" Description="Compressive strength, α=0°." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="CompStrengthPerp_0Sk7rdMlL1rwa$77Tmc3ZF" GlobalId="0Sk7rdMlL1rwa$77Tmc3ZF" Name="CompStrengthPerp" Description="Compressive strength, α=90°." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="CompStrengthPerp_1nDJCoibTCpv6h14fhaGKZ" GlobalId="1nDJCoibTCpv6h14fhaGKZ" Name="CompStrengthPerp" Description="Compressive strength, α=90°." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="CompStrengthPerp_3Q2AaIwNj5sfrocKwUvdtT" GlobalId="3Q2AaIwNj5sfrocKwUvdtT" Name="CompStrengthPerp" Description="Compressive strength, α=90°." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="ConcealedCeiling_1r0lqqj$f9Ge364Ax4U713" GlobalId="1r0lqqj$f9Ge364Ax4U713" Name="ConcealedCeiling" Description="Indication whether this space is designed to have a concealed flooring space (TRUE) or not (FALSE). A concealed ceiling space is normally meant to be the space between a slab and a ceiling." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="ConcealedCeilingOffset_2dq7B8tp95lPmRb2JNyrg7" GlobalId="2dq7B8tp95lPmRb2JNyrg7" Name="ConcealedCeilingOffset" Description="Distance between the upper floor slab and the suspended ceiling, often used for distribution systems. Often referred to as plenum." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNonNegativeLengthMeasure" />
				<IfcSimplePropertyTemplate id="ConcealedFlooring_26KAQ9kWPDzfy5AeUh1my2" GlobalId="26KAQ9kWPDzfy5AeUh1my2" Name="ConcealedFlooring" Description="Indication whether this space is designed to have a concealed flooring space (TRUE) or not (FALSE). A concealed flooring space is normally meant to be the space beneath a raised floor." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="ConcealedFlooringOffset_1M0f51fy10nAxr6YGleM4V" GlobalId="1M0f51fy10nAxr6YGleM4V" Name="ConcealedFlooringOffset" Description="Distance between the floor slab and the floor covering, often used for cables and other installations. Often referred to as raised flooring." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNonNegativeLengthMeasure" />
				<IfcSimplePropertyTemplate id="ConcreteCover_07PBZZQdn2TOMV5JJgFkm9" GlobalId="07PBZZQdn2TOMV5JJgFkm9" Name="ConcreteCover" Description="The protective concrete cover at the reinforcing bars according to local building regulations." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ConcreteCoverAtLinks_2_yow0qSiHuO00025QrE$V" GlobalId="2_yow0qSiHuO00025QrE$V" Name="ConcreteCoverAtLinks" Description="The protective concrete cover at the reinforcement links according to local building regulations." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ConcreteCoverAtMainBars_2u$Ks0qSiHuO00025QrE$V" GlobalId="2u$Ks0qSiHuO00025QrE$V" Name="ConcreteCoverAtMainBars" Description="The protective concrete cover at the main reinforcing bars according to local building regulations." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="CondenserEnteringTemperature_2Jb380qXCHuO00025QrE$V" GlobalId="2Jb380qXCHuO00025QrE$V" Name="CondenserEnteringTemperature" Description="Temperature of fluid entering condenser." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="CondenserFlowrate_2Ddb40qXCHuO00025QrE$V" GlobalId="2Ddb40qXCHuO00025QrE$V" Name="CondenserFlowrate" Description="Flow rate of fluid through the condenser." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="CondenserLeavingTemperature_2RKzQ0qXCHuO00025QrE$V" GlobalId="2RKzQ0qXCHuO00025QrE$V" Name="CondenserLeavingTemperature" Description="Temperature of fluid leaving condenser." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="CondenserMeanVoidFraction_21GjM0qSmHuO00025QrE$V" GlobalId="21GjM0qSmHuO00025QrE$V" Name="CondenserMeanVoidFraction" Description="Mean void fraction in condenser." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="CondensingTemperature_1ko9m0qSmHuO00025QrE$V" GlobalId="1ko9m0qSmHuO00025QrE$V" Name="CondensingTemperature" Description="Refrigerant condensing temperature." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="ConditionCommencement_2Gs1E0qVWHuO00025QrE$V" GlobalId="2Gs1E0qVWHuO00025QrE$V" Name="ConditionCommencement" Description="Condition of property provided on commencement of the agreement e.g. cold shell, warm lit shell, broom clean, turn-key." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="ConditionDisposalLevel_1gLmRZ_wH63g1ueUzbq2sS" GlobalId="1gLmRZ_wH63g1ueUzbq2sS" Name="ConditionDisposalLevel" Description="Condition that will trigger a disposal process" TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i199" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ConditionHistory_3lWPi0qS0HuO00025QrE$V" GlobalId="3lWPi0qS0HuO00025QrE$V" Name="ConditionHistory" Description="Indicates alarm condition over time.  The range of possible values and their meanings is defined by Pset_AlarmTypeCommon.Condition.  An empty value indicates no present alarm condition." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcIdentifier" />
				<IfcSimplePropertyTemplate id="ConditionMaintenanceLevel_0VfTbc1grAZhnktO2lISqM" GlobalId="0VfTbc1grAZhnktO2lISqM" Name="ConditionMaintenanceLevel" Description="Condition that will trigger maintenance" TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i199" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ConditionReplacementLevel_18kxxoTgD8MAVYfHV0plY$" GlobalId="18kxxoTgD8MAVYfHV0plY$" Name="ConditionReplacementLevel" Description="Condition that will trigger a replacement process" TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i199" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ConditionTargetPerformance_2iDip8GTT8zRWOR2gRk8Qk" GlobalId="2iDip8GTT8zRWOR2gRk8Qk" Name="ConditionTargetPerformance" Description="Target condition of the asset" TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i199" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ConditionTermination_2WLro0qVWHuO00025QrE$V" GlobalId="2WLro0qVWHuO00025QrE$V" Name="ConditionTermination" Description="Condition of property required on termination of the agreement e.g. cold shell, warm lit shell, broom clean, turn-key." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="ConductorDiameter_2LgQvvudb6UBQkAzoEIL3k" GlobalId="2LgQvvudb6UBQkAzoEIL3k" Name="ConductorDiameter" Description="Indicates the conductor diameter. It is only used for twisted and untwisted wire pair." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ConductorFunction_03sO5GIyzFT8intkW6NLbP" GlobalId="03sO5GIyzFT8intkW6NLbP" Name="ConductorFunction" Description="Indicates function of the conductors to which the load is connected. Where L1, L2 and L3 represent the phase lines according to IEC 60446 notation (sometimes phase lines may be referenced by color [Red, Blue, Yellow] or by number [1, 2, 3] etc). Protective Earth is sometimes also known as CPC or common protective conductor. Note that for an electrical device, a set of line conductor functions may be applied." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" id="i571" Name="PEnum_ConductorFunctionEnum">
						<EnumerationValues>
							<IfcLabel-wrapper>PHASE_L1</IfcLabel-wrapper>
							<IfcLabel-wrapper>PHASE_L2</IfcLabel-wrapper>
							<IfcLabel-wrapper>PHASE_L3</IfcLabel-wrapper>
							<IfcLabel-wrapper>NEUTRAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>PROTECTIVEEARTH</IfcLabel-wrapper>
							<IfcLabel-wrapper>PROTECTIVEEARTHNEUTRAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ConductorFunction_3vDX0hr89BVhc9fLSUDJTm" GlobalId="3vDX0hr89BVhc9fLSUDJTm" Name="ConductorFunction" Description="Indicates function of the conductors to which the load is connected. Where L1, L2 and L3 represent the phase lines according to IEC 60446 notation (sometimes phase lines may be referenced by color [Red, Blue, Yellow] or by number [1, 2, 3] etc). Protective Earth is sometimes also known as CPC or common protective conductor. Note that for an electrical device, a set of line conductor functions may be applied." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i571" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ConductorMaterial_10uLY0qSWHuO00025QrE$V" GlobalId="10uLY0qSWHuO00025QrE$V" Name="ConductorMaterial" Description="Type of material from which the conductor is constructed." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_MaterialEnum">
						<EnumerationValues>
							<IfcLabel-wrapper>ALUMINIUM</IfcLabel-wrapper>
							<IfcLabel-wrapper>COPPER</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ConductorShape_1PwWc0qSWHuO00025QrE$V" GlobalId="1PwWc0qSWHuO00025QrE$V" Name="ConductorShape" Description="Indication of the shape of the conductor." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ShapeEnum">
						<EnumerationValues>
							<IfcLabel-wrapper>HELICALCONDUCTOR</IfcLabel-wrapper>
							<IfcLabel-wrapper>CIRCULARCONDUCTOR</IfcLabel-wrapper>
							<IfcLabel-wrapper>SECTORCONDUCTOR</IfcLabel-wrapper>
							<IfcLabel-wrapper>RECTANGULARCONDUCTOR</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ConduitShapeType_3b_p60qSOHuO00025QrE$V" GlobalId="3b_p60qSOHuO00025QrE$V" Name="ConduitShapeType" Description="The shape of the conduit segment." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ConduitShapeType">
						<EnumerationValues>
							<IfcLabel-wrapper>CIRCULAR</IfcLabel-wrapper>
							<IfcLabel-wrapper>OVAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ConicityRatio_1q2DJWtf58PvkMOQBrIqOF" GlobalId="1q2DJWtf58PvkMOQBrIqOF" Name="ConicityRatio" Description="The ratio of the diameter of the cone bottom surface to the height of the pole." TemplateType="p_singlevalue" PrimaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="ConnectedConductorFunction_0zyc80qU0HuO00025QrE$V" GlobalId="0zyc80qU0HuO00025QrE$V" Name="ConnectedConductorFunction" Description="Function of the conductors to which the load is connected." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i571" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ConnectionGender_1QcnE_aj55XODZJWLi4uym" GlobalId="1QcnE_aj55XODZJWLi4uym" Name="ConnectionGender" Description="The physical connection gender." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" id="i582" Name="PEnum_DistributionPortGender">
						<EnumerationValues>
							<IfcLabel-wrapper>MALE</IfcLabel-wrapper>
							<IfcLabel-wrapper>FEMALE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ConnectionSize_1SN5k0qUWHuO00025QrE$V" GlobalId="1SN5k0qUWHuO00025QrE$V" Name="ConnectionSize" Description="The connection size of the object.

Inlet and outlet pipe connections to the meter." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ConnectionSize_23Pbs0qUSHuO00025QrE$V" GlobalId="23Pbs0qUSHuO00025QrE$V" Name="ConnectionSize" Description="The connection size of the object.

Inlet connection to sprinkler." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ConnectionSize_2WGcS0qSuHuO00025QrE$V" GlobalId="2WGcS0qSuHuO00025QrE$V" Name="ConnectionSize" Description="The connection size of the object.

Duct connection diameter." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ConnectionSize_3chxe0qVuHuO00025QrE$V" GlobalId="3chxe0qVuHuO00025QrE$V" Name="ConnectionSize" Description="The connection size of the object.

The connection to and from the pump." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ConnectionSubtype_0LsHRT7ND0l8585NRu7Ie8" GlobalId="0LsHRT7ND0l8585NRu7Ie8" Name="ConnectionSubtype" Description="The physical port connection subtype that further qualifies the ConnectionType. The following values are recommended:

ACPLUG: A, B, C, D, E, F, EF, G, H, I, J, K, L, M
DIN: Mini3P, Mini4P, Mini5P, Mini6P, Mini7P, Mini8P, Mini9P
DSub: DA15, DB25, DC37, DD50, DE9, DE15
EIAJ: RC5720
HDMI: A, B, C
RADIO: IEEE802.11g, IEEE802.11n
RJ: 4P4C, 6P2C, 8P8C
SOCKET: E-11, E-12, E-14, E-17, E-26, E-27, E-39, E-40
TRS: TS_Mini, TS_SubMini, TRS_Mini, TRS_SubMini" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ConnectionSubtype_1A5cORvpX3_vdhIOgP0LY0" GlobalId="1A5cORvpX3_vdhIOgP0LY0" Name="ConnectionSubtype" Description="The physical port connection subtype that further qualifies the ConnectionType. The following values are recommended:

ACPLUG: A, B, C, D, E, F, EF, G, H, I, J, K, L, M
DIN: Mini3P, Mini4P, Mini5P, Mini6P, Mini7P, Mini8P, Mini9P
DSub: DA15, DB25, DC37, DD50, DE9, DE15
EIAJ: RC5720
HDMI: A, B, C
RADIO: IEEE802.11g, IEEE802.11n
RJ: 4P4C, 6P2C, 8P8C
SOCKET: E-11, E-12, E-14, E-17, E-26, E-27, E-39, E-40
TRS: TS_Mini, TS_SubMini, TRS_Mini, TRS_SubMini" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ConnectionSubtype_3V7JbtIxHAZPR8CmMAy3dW" GlobalId="3V7JbtIxHAZPR8CmMAy3dW" Name="ConnectionSubtype" Description="The physical port connection subtype that further qualifies the ConnectionType. The following values are recommended:

ACPLUG: A, B, C, D, E, F, EF, G, H, I, J, K, L, M
DIN: Mini3P, Mini4P, Mini5P, Mini6P, Mini7P, Mini8P, Mini9P
DSub: DA15, DB25, DC37, DD50, DE9, DE15
EIAJ: RC5720
HDMI: A, B, C
RADIO: IEEE802.11g, IEEE802.11n
RJ: 4P4C, 6P2C, 8P8C
SOCKET: E-11, E-12, E-14, E-17, E-26, E-27, E-39, E-40
TRS: TS_Mini, TS_SubMini, TRS_Mini, TRS_SubMini" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ConnectionType_3IiZcc7R5CAhGZuzSrfjuV" GlobalId="3IiZcc7R5CAhGZuzSrfjuV" Name="ConnectionType" Description="The end-style treatment of the duct port:

BEADEDSLEEVE: Beaded Sleeve. COMPRESSION: Compression. CRIMP: Crimp. DRAWBAND: Drawband. DRIVESLIP: Drive slip. FLANGED: Flanged. OUTSIDESLEEVE: Outside Sleeve. SLIPON: Slipon. SOLDERED: Soldered. SSLIP: S-Slip. STANDINGSEAM: Standing seam. SWEDGE: Swedge. WELDED: Welded. OTHER: Another type of end-style has been applied. NONE: No end-style has been applied." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_DuctConnectionType">
						<EnumerationValues>
							<IfcLabel-wrapper>BEADEDSLEEVE</IfcLabel-wrapper>
							<IfcLabel-wrapper>COMPRESSION</IfcLabel-wrapper>
							<IfcLabel-wrapper>CRIMP</IfcLabel-wrapper>
							<IfcLabel-wrapper>DRAWBAND</IfcLabel-wrapper>
							<IfcLabel-wrapper>DRIVESLIP</IfcLabel-wrapper>
							<IfcLabel-wrapper>FLANGED</IfcLabel-wrapper>
							<IfcLabel-wrapper>OUTSIDESLEEVE</IfcLabel-wrapper>
							<IfcLabel-wrapper>SLIPON</IfcLabel-wrapper>
							<IfcLabel-wrapper>SOLDERED</IfcLabel-wrapper>
							<IfcLabel-wrapper>SSLIP</IfcLabel-wrapper>
							<IfcLabel-wrapper>STANDINGSEAM</IfcLabel-wrapper>
							<IfcLabel-wrapper>SWEDGE</IfcLabel-wrapper>
							<IfcLabel-wrapper>WELDED</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NONE</IfcLabel-wrapper>
							<IfcLabel-wrapper>USERDEFINED</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTDEFINED</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ConnectionType_3uGgYTZiL73BYwV_npECRZ" GlobalId="3uGgYTZiL73BYwV_npECRZ" Name="ConnectionType" Description="The end-style treatment of the pipe port:

BRAZED: Brazed. 
COMPRESSION: Compression. 
FLANGED: Flanged. 
GROOVED: Grooved. 
OUTSIDESLEEVE: Outside Sleeve. 
SOLDERED: Soldered. 
SWEDGE: Swedge. 
THREADED: Threaded. 
WELDED: Welded. 
OTHER: Another type of end-style has been applied.
NONE: No end-style has been applied.
USERDEFINED: User-defined port connection type. 
NOTDEFINED: Undefined port connection type." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_PipeEndStyleTreatment">
						<EnumerationValues>
							<IfcLabel-wrapper>BRAZED</IfcLabel-wrapper>
							<IfcLabel-wrapper>COMPRESSION</IfcLabel-wrapper>
							<IfcLabel-wrapper>FLANGED</IfcLabel-wrapper>
							<IfcLabel-wrapper>GROOVED</IfcLabel-wrapper>
							<IfcLabel-wrapper>OUTSIDESLEEVE</IfcLabel-wrapper>
							<IfcLabel-wrapper>SOLDERED</IfcLabel-wrapper>
							<IfcLabel-wrapper>SWEDGE</IfcLabel-wrapper>
							<IfcLabel-wrapper>THREADED</IfcLabel-wrapper>
							<IfcLabel-wrapper>WELDED</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NONE</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ConnectorAColour_0w0gEEc0zFjvNswSrKmDQ$" GlobalId="0w0gEEc0zFjvNswSrKmDQ$" Name="ConnectorAColour" Description="Indicates the colour A- end of connector." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ConnectorAGender_3yUsi5u7T4BQGLpkunPPI0" GlobalId="3yUsi5u7T4BQGLpkunPPI0" Name="ConnectorAGender" Description="Indicates the gender of A-end connector." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i582" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ConnectorAType_05lh3wrjD3fe$BEp5kTIqH" GlobalId="05lh3wrjD3fe$BEp5kTIqH" Name="ConnectorAType" Description="Indicates the type of A-end connector." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ConnectorBColour_1cThVIaMXEcAEobfXJFIPy" GlobalId="1cThVIaMXEcAEobfXJFIPy" Name="ConnectorBColour" Description="Indicates the colour B- end of connector." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ConnectorBGender_3iBqO$VGP8tOJhBPjhmLpB" GlobalId="3iBqO$VGP8tOJhBPjhmLpB" Name="ConnectorBGender" Description="Indicates the gender of B-end connector." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i582" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ConnectorBType_2xjdteWAjCdRxhbBMzx0M0" GlobalId="2xjdteWAjCdRxhbBMzx0M0" Name="ConnectorBType" Description="Indicates the type of B-end connector." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ConnectorType_3hZprW7ZTEuRugKKQVaEZ3" GlobalId="3hZprW7ZTEuRugKKQVaEZ3" Name="ConnectorType" Description="Indicates the type of connector." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ConsistencyIndex_2o9pe5Y8DEiR3DEK$WihGW" GlobalId="2o9pe5Y8DEiR3DEK$WihGW" Name="ConsistencyIndex" Description="The consistency index (Ic) indicates the consistency (firmness) of a soil. It is the numerical difference between the liquid limit and the natural water content expressed as a percentage ratio of the plasticity index. Ic = (LL-W)/Ip." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="Construction_1CpHg0qSWHuO00025QrE$V" GlobalId="1CpHg0qSWHuO00025QrE$V" Name="Construction" Description="Purpose of informing on how the conductor is constructed (interwined or solid). I.e. Solid (IEV 461-01-06), stranded (IEV 461-01-07), solid-/finestranded(IEV 461-01-11) (not flexible/flexible)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ConstructionEnum">
						<EnumerationValues>
							<IfcLabel-wrapper>SOLIDCONDUCTOR</IfcLabel-wrapper>
							<IfcLabel-wrapper>STRANDEDCONDUCTOR</IfcLabel-wrapper>
							<IfcLabel-wrapper>FLEXIBLESTRANDEDCONDUCTOR</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ConstructionMethod_3$0kC0qSGHuO00025QrE$V" GlobalId="3$0kC0qSGHuO00025QrE$V" Name="ConstructionMethod" Description="The type of construction action to the object, e.g. new construction, renovation, refurbishment, etc." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ConstructionToleranceClass_2hu5w0qSiHuO00025QrE$V" GlobalId="2hu5w0qSiHuO00025QrE$V" Name="ConstructionToleranceClass" Description="Classification designation of the on-site construction tolerances according to local standards." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ContactorType_3ti$U0qWqHuO00025QrE$V" GlobalId="3ti$U0qWqHuO00025QrE$V" Name="ContactorType" Description="A list of the available types of contactor from which that required may be selected where:

CapacitorSwitching: for switching 3 phase single or multi-step capacitor banks.
LowCurrent: requires the use of low resistance contacts.
MagneticLatching: enables the contactor to remain in the on position when the coil is no longer energized.
MechanicalLatching: requires that the contactor is mechanically retained in the on position.
Modular: are totally enclosed and self contained.
Reversing: has a double set of contactors that are prewired.
Standard: is a generic device that controls the flow of power in a circuit on or off." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ContactorType">
						<EnumerationValues>
							<IfcLabel-wrapper>CAPACITORSWITCHING</IfcLabel-wrapper>
							<IfcLabel-wrapper>LOWCURRENT</IfcLabel-wrapper>
							<IfcLabel-wrapper>MAGNETICLATCHING</IfcLabel-wrapper>
							<IfcLabel-wrapper>MECHANICALLATCHING</IfcLabel-wrapper>
							<IfcLabel-wrapper>MODULAR</IfcLabel-wrapper>
							<IfcLabel-wrapper>REVERSING</IfcLabel-wrapper>
							<IfcLabel-wrapper>STANDARD</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ContactResistance_0MnIrCS5P7TweCZZThUwtm" GlobalId="0MnIrCS5P7TweCZZThUwtm" Name="ContactResistance" Description="Resistance when electrical node is closed." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricResistanceMeasure" />
				<IfcSimplePropertyTemplate id="ContactWireNominalDrop_0PafkcBBDBPAuLjLmX5W1c" GlobalId="0PafkcBBDBPAuLjLmX5W1c" Name="ContactWireNominalDrop" Description="Vertical distance between the main catenary wire and the contact wire measured at a support point." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ContactWireNominalHeight_1WIgSUjRrA2vcLynsmAyg4" GlobalId="1WIgSUjRrA2vcLynsmAyg4" Name="ContactWireNominalHeight" Description="Nominal distance from the top of the rail to the lower face of the contact wire, measured perpendicular to the track." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ContactWireStagger_1dWD_52DDFheUkLfvK_Wga" GlobalId="1dWD_52DDFheUkLfvK_Wga" Name="ContactWireStagger" Description="Lateral displacement of the contact wire to opposite sides of the track centre at successive supports." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ContactWireUplift_2SxilVeerCTud05s6E45Pj" GlobalId="2SxilVeerCTud05s6E45Pj" Name="ContactWireUplift" Description="Vertical upward movement of the contact wire due to the force produced from the pantograph." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNonNegativeLengthMeasure" />
				<IfcSimplePropertyTemplate id="ContainerMaterial_1EgzE0qV8HuO00025QrE$V" GlobalId="1EgzE0qV8HuO00025QrE$V" Name="ContainerMaterial" Description="Special requirements for material used to contain an artefact." TemplateType="p_referencevalue" PrimaryMeasureType="IfcMaterialDefinition" />
				<IfcSimplePropertyTemplate id="ContaminantVolume_3j3luG3knB79dbgpp9O2W0" GlobalId="3j3luG3knB79dbgpp9O2W0" Name="ContaminantVolume" Description="Relative volume of contaminant stratum constituents." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumeMeasure" />
				<IfcSimplePropertyTemplate id="Contamination_2MUPtI9NP8bvLCMAJRde53" GlobalId="2MUPtI9NP8bvLCMAJRde53" Name="Contamination" Description="Expected anthropogenic contaminations." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ContourValue_0q3JQ0qS4HuO00025QrE$V" GlobalId="0q3JQ0qS4HuO00025QrE$V" Name="ContourValue" Description="Value of the elevation of the contour above or below a reference plane." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="ContractualType_0FW840qVWHuO00025QrE$V" GlobalId="0FW840qVWHuO00025QrE$V" Name="ContractualType" Description="The contractual type of the work." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="ContractualType_1b25u0qVSHuO00025QrE$V" GlobalId="1b25u0qVSHuO00025QrE$V" Name="ContractualType" Description="The contractual type of the work." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="ContrastRatio_2mxE00qS8HuO00025QrE$V" GlobalId="2mxE00qS8HuO00025QrE$V" Name="ContrastRatio" Description="Indicates the display contrast ratio." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="ContributedLuminousFlux_0Fna_0qUiHuO00025QrE$V" GlobalId="0Fna_0qUiHuO00025QrE$V" Name="ContributedLuminousFlux" Description="Luminous flux is a photometric measure of radiant flux, i.e. the volume of light emitted from a light source. Luminous flux is measured either for the interior as a whole or for a part of the interior (partial luminous flux for a solid angle). All other photometric parameters are derivatives of luminous flux. Luminous flux is measured in lumens (lm). The luminous flux is given as a nominal value for each lamp." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLuminousFluxMeasure" />
				<IfcSimplePropertyTemplate id="ControlDamperOperation_2g6Pc0qT4HuO00025QrE$V" GlobalId="2g6Pc0qT4HuO00025QrE$V" Name="ControlDamperOperation" Description="The inherent characteristic of the control damper operation." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ControlDamperOperation">
						<EnumerationValues>
							<IfcLabel-wrapper>LINEAR</IfcLabel-wrapper>
							<IfcLabel-wrapper>EXPONENTIAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ControlPulseCurrent_1NbOptutP7sPdNxheUF3ur" GlobalId="1NbOptutP7sPdNxheUF3ur" Name="ControlPulseCurrent" Description="The current of the electric actuator control pulse." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="ControlStrategy_35WwK0qSyHuO00025QrE$V" GlobalId="35WwK0qSyHuO00025QrE$V" Name="ControlStrategy" Description="FixedExitingWaterTemp: The capacity is controlled to maintain a fixed exiting water temperature.
WetBulbTempReset: The set-point is reset based on the wet-bulb temperature." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_CoolingTowerControlStrategy">
						<EnumerationValues>
							<IfcLabel-wrapper>FIXEDEXITINGWATERTEMP</IfcLabel-wrapper>
							<IfcLabel-wrapper>WETBULBTEMPRESET</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ControlType_02vpC0qSuHuO00025QrE$V" GlobalId="02vpC0qSuHuO00025QrE$V" Name="ControlType" Description="The type controller, signal modification effected and applicable ports

LOWERLIMITSWITCH: Single analog input is read and if less than Value.LowerBound then True is written to the output value.
UPPERLIMITSWITCH: Single analog input is read and if more than Value.UpperBound then True is written to the output value.
LOWERBANDSWITCH: Single analog input is read and if less than Value.LowerBound+BandWidth then True is written to the output value.
UPPERBANDSWITCH: Single analog input is read and if more than Value.UpperBound-BandWidth then True is written to the output value.
NOT: Single binary input is read and the opposite value is written to the output value.
AND: Two binary inputs are read and if both are True then True is written to the output value.
OR: Two binary inputs are read and if either is True then True is written to the output value.
XOR: Two binary inputs are read and if one is true then True is written to the output value.
CALENDAR: No inputs; the current time is compared with an IfcWorkCalendar to which the IfcController is assigned and True is written if active.
INPUT: Controller element is a dedicated input.
OUTPUT: Controller element is a dedicated output.
VARIABLE: Controller element is an in-memory variable." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ControllerTwoPositionType">
						<EnumerationValues>
							<IfcLabel-wrapper>NOT</IfcLabel-wrapper>
							<IfcLabel-wrapper>AND</IfcLabel-wrapper>
							<IfcLabel-wrapper>OR</IfcLabel-wrapper>
							<IfcLabel-wrapper>XOR</IfcLabel-wrapper>
							<IfcLabel-wrapper>LOWERLIMITSWITCH</IfcLabel-wrapper>
							<IfcLabel-wrapper>UPPERLIMITSWITCH</IfcLabel-wrapper>
							<IfcLabel-wrapper>LOWERBANDSWITCH</IfcLabel-wrapper>
							<IfcLabel-wrapper>UPPERBANDSWITCH</IfcLabel-wrapper>
							<IfcLabel-wrapper>AVERAGE</IfcLabel-wrapper>
							<IfcLabel-wrapper>CALENDAR</IfcLabel-wrapper>
							<IfcLabel-wrapper>INPUT</IfcLabel-wrapper>
							<IfcLabel-wrapper>OUTPUT</IfcLabel-wrapper>
							<IfcLabel-wrapper>VARIABLE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ControlType_0kjUa0qSqHuO00025QrE$V" GlobalId="0kjUa0qSqHuO00025QrE$V" Name="ControlType" Description="The type controller, signal modification effected and applicable ports

CONSTANT: No inputs; SignalOffset is written to the output value.
MODIFIER: Single analog input is read, added to SignalOffset, multiplied by SignalFactor, and written to the output value.
ABSOLUTE: Single analog input is read and absolute value is written to the output value.
INVERSE: Single analog input is read, 1.0 is divided by the input value and written to the output value.
HYSTERISIS: Single analog input is read, delayed according to SignalTime, and written to the output value.
RUNNINGAVERAGE: Single analog input is read, averaged over SignalTime, and written to the output value.
DERIVATIVE: Single analog input is read and the rate of change during the SignalTime is written to the output value.
INTEGRAL: Single analog input is read and the average value during the SignalTime is written to the output value.
BINARY: Single binary input is read and SignalOffset is written to the output value if True.
ACCUMULATOR: Single binary input is read, and for each pulse the SignalOffset is added to the accumulator, and while the accumulator is greater than the SignalFactor, the accumulator is decremented by SignalFactor and the integer result is incremented by one.
PULSECONVERTER: Single integer input is read, and for each increment the SignalMultiplier is added and written to the output value.
SUM: Two analog inputs are read, added, and written to the output value.
SUBTRACT: Two analog inputs are read, subtracted, and written to the output value.
PRODUCT: Two analog inputs are read, multiplied, and written to the output value.
DIVIDE: Two analog inputs are read, divided, and written to the output value.
AVERAGE: Two analog inputs are read and the average is written to the output value.
MAXIMUM: Two analog inputs are read and the maximum is written to the output value.
MINIMUM: Two analog inputs are read and the minimum is written to the output value..
INPUT: Controller element is a dedicated input.
OUTPUT: Controller element is a dedicated output.
VARIABLE: Controller element is an in-memory variable." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ControllerTypeFloating">
						<EnumerationValues>
							<IfcLabel-wrapper>CONSTANT</IfcLabel-wrapper>
							<IfcLabel-wrapper>MODIFIER</IfcLabel-wrapper>
							<IfcLabel-wrapper>ABSOLUTE</IfcLabel-wrapper>
							<IfcLabel-wrapper>INVERSE</IfcLabel-wrapper>
							<IfcLabel-wrapper>HYSTERESIS</IfcLabel-wrapper>
							<IfcLabel-wrapper>RUNNINGAVERAGE</IfcLabel-wrapper>
							<IfcLabel-wrapper>DERIVATIVE</IfcLabel-wrapper>
							<IfcLabel-wrapper>INTEGRAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>BINARY</IfcLabel-wrapper>
							<IfcLabel-wrapper>ACCUMULATOR</IfcLabel-wrapper>
							<IfcLabel-wrapper>PULSECONVERTER</IfcLabel-wrapper>
							<IfcLabel-wrapper>LOWERLIMITCONTROL</IfcLabel-wrapper>
							<IfcLabel-wrapper>UPPERLIMITCONTROL</IfcLabel-wrapper>
							<IfcLabel-wrapper>SUM</IfcLabel-wrapper>
							<IfcLabel-wrapper>SUBTRACT</IfcLabel-wrapper>
							<IfcLabel-wrapper>PRODUCT</IfcLabel-wrapper>
							<IfcLabel-wrapper>DIVIDE</IfcLabel-wrapper>
							<IfcLabel-wrapper>AVERAGE</IfcLabel-wrapper>
							<IfcLabel-wrapper>MAXIMUM</IfcLabel-wrapper>
							<IfcLabel-wrapper>MINIMUM</IfcLabel-wrapper>
							<IfcLabel-wrapper>REPORT</IfcLabel-wrapper>
							<IfcLabel-wrapper>SPLIT</IfcLabel-wrapper>
							<IfcLabel-wrapper>INPUT</IfcLabel-wrapper>
							<IfcLabel-wrapper>OUTPUT</IfcLabel-wrapper>
							<IfcLabel-wrapper>VARIABLE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ControlType_0NBIy0qT8HuO00025QrE$V" GlobalId="0NBIy0qT8HuO00025QrE$V" Name="ControlType" Description="The type controller, signal modification effected and applicable ports" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ControlType_1_bB00qSqHuO00025QrE$V" GlobalId="1_bB00qSqHuO00025QrE$V" Name="ControlType" Description="The type controller, signal modification effected and applicable ports

INPUT: Controller element is a dedicated input.
OUTPUT: Controller element is a dedicated output.
VARIABLE: Controller element is an in-memory variable." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ControllerMultiPositionType">
						<EnumerationValues>
							<IfcLabel-wrapper>INPUT</IfcLabel-wrapper>
							<IfcLabel-wrapper>OUTPUT</IfcLabel-wrapper>
							<IfcLabel-wrapper>VARIABLE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ControlType_2X9ia0qSqHuO00025QrE$V" GlobalId="2X9ia0qSqHuO00025QrE$V" Name="ControlType" Description="The type controller, signal modification effected and applicable ports

PRIMARY: Controller has built-in communication interface for PC connection, may manage secondary controllers.
SECONDARY: Controller communicates with primary controller and its own managed devices." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ControllerTypeProgrammable">
						<EnumerationValues>
							<IfcLabel-wrapper>PRIMARY</IfcLabel-wrapper>
							<IfcLabel-wrapper>SECONDARY</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ControlType_2zAcg0qSqHuO00025QrE$V" GlobalId="2zAcg0qSqHuO00025QrE$V" Name="ControlType" Description="The type controller, signal modification effected and applicable ports

PROPORTIONAL: Output is proportional to the control error. The gain of a proportional control (Kp) will have the effect of reducing the rise time and reducing , but never eliminating, the steady-state error of the variable controlled.
PROPORTIONALINTEGRAL: Part of the output is proportional to the control error and part is proportional to the time integral of the control error. Adding the gain of an integral control (Ki) will have the effect of eliminating the steady-state error of the variable controlled, but it may make the transient response worse.
PROPORTIONALINTEGRALDERIVATIVE: Part of the output is proportional to the control error, part is proportional to the time integral of the control error and part is proportional to the time derivative of the control error. Adding the gain of a derivative control (Kd) will have the effect of increasing the stability of the system, reducing the overshoot, and improving the transient response of the variable controlled." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ControllerProportionalType">
						<EnumerationValues>
							<IfcLabel-wrapper>PROPORTIONAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>PROPORTIONALINTEGRAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>PROPORTIONALINTEGRALDERIVATIVE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ConvectorType_1_PjM0qWeHuO00025QrE$V" GlobalId="1_PjM0qWeHuO00025QrE$V" Name="ConvectorType" Description="Indicates the type of convector, whether forced air (mechanically driven) or natural (gravity)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_SpaceHeaterConvectorType">
						<EnumerationValues>
							<IfcLabel-wrapper>FORCED</IfcLabel-wrapper>
							<IfcLabel-wrapper>NATURAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ConversionTime_05csar1WP7SPvQFGopUOit" GlobalId="05csar1WP7SPvQFGopUOit" Name="ConversionTime" Description="Turnout conversion completion time." TemplateType="p_singlevalue" PrimaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="CoolingAirFlowRate_0d_fQ0qWmHuO00025QrE$V" GlobalId="0d_fQ0qWmHuO00025QrE$V" Name="CoolingAirFlowRate" Description="Cooling air flow rate in the space." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="CoolingDesignAirFlow_0P_4O0qWiHuO00025QrE$V" GlobalId="0P_4O0qWiHuO00025QrE$V" Name="CoolingDesignAirFlow" Description="The air flowrate required during the peak cooling conditions." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="CoolingDesignDay_0EJ5M0qV8HuO00025QrE$V" GlobalId="0EJ5M0qV8HuO00025QrE$V" Name="CoolingDesignDay" Description="The month, day and time that has been selected for the cooling design calculations." TemplateType="p_singlevalue" PrimaryMeasureType="IfcDateTime" />
				<IfcSimplePropertyTemplate id="CoolingDryBulb_03aS20qV8HuO00025QrE$V" GlobalId="03aS20qV8HuO00025QrE$V" Name="CoolingDryBulb" Description="Dry bulb temperature, usually for for cooling design.

Outside dry bulb temperature" TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="CoolingDryBulb_0uNa60qWiHuO00025QrE$V" GlobalId="0uNa60qWiHuO00025QrE$V" Name="CoolingDryBulb" Description="Inside dry bulb temperature for cooling design." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="CoolingDryBulb_23i_oDW4nDfBvb_ImqAD5i" GlobalId="23i_oDW4nDfBvb_ImqAD5i" Name="CoolingDryBulb" Description="Dry bulb temperature, usually for for cooling design." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="CoolingEfficiency_1xlAu0qXCHuO00025QrE$V" GlobalId="1xlAu0qXCHuO00025QrE$V" Name="CoolingEfficiency" Description="Coefficient of Performance: Ratio of cooling energy output to energy input under full load operating conditions." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="CoolingRelativeHumidity_0zkum0qWiHuO00025QrE$V" GlobalId="0zkum0qWiHuO00025QrE$V" Name="CoolingRelativeHumidity" Description="Inside relative humidity for cooling design." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="CoolingTemperatureDelta_13rqk0qRuHuO00025QrE$V" GlobalId="13rqk0qRuHuO00025QrE$V" Name="CoolingTemperatureDelta" Description="Cooling temperature difference for calculating space air flow rates." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="CoolingWaterFlowRate_16GQ60qSuHuO00025QrE$V" GlobalId="16GQ60qSuHuO00025QrE$V" Name="CoolingWaterFlowRate" Description="Water flow rate for cooling." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="CoolingWetBulb_08xmi0qV8HuO00025QrE$V" GlobalId="08xmi0qV8HuO00025QrE$V" Name="CoolingWetBulb" Description="Outside wet bulb temperature for cooling design." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="CoreBaseHeight_0BKsG0qVOHuO00025QrE$V" GlobalId="0BKsG0qVOHuO00025QrE$V" Name="CoreBaseHeight" Description="Core base height of the profile." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="CoreBaseWidth_0WB$U0qVOHuO00025QrE$V" GlobalId="0WB$U0qVOHuO00025QrE$V" Name="CoreBaseWidth" Description="Core base width of the profile." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="CoreConductorDiameter_3ZwqVh2H99qOG$$4R$j3QX" GlobalId="3ZwqVh2H99qOG$$4R$j3QX" Name="CoreConductorDiameter" Description="Indicates the core conductor diameter. It is only used for coaxial wire pair." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="CoreIdentifier_2Cb080qSWHuO00025QrE$V" GlobalId="2Cb080qSWHuO00025QrE$V" Name="CoreIdentifier" Description="The core identification used Identifiers may be used such as by color (Black, Brown, Grey) or by number (1, 2, 3) or by IEC phase reference (L1, L2, L3) etc." TemplateType="p_singlevalue" PrimaryMeasureType="IfcIdentifier" />
				<IfcSimplePropertyTemplate id="CoreMiddleHeight_0HuTk0qVOHuO00025QrE$V" GlobalId="0HuTk0qVOHuO00025QrE$V" Name="CoreMiddleHeight" Description="Core middle height of the profile." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="CoreSetHorizontal_0Qjxg0qS0HuO00025QrE$V" GlobalId="0Qjxg0qS0HuO00025QrE$V" Name="CoreSetHorizontal" Description="Degree of horizontal (in the X-axis of the LocalPlacement) blade set from the centerline." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="CoreSetVertical_0VV6w0qS0HuO00025QrE$V" GlobalId="0VV6w0qS0HuO00025QrE$V" Name="CoreSetVertical" Description="Degree of vertical (in the Y-axis of the LocalPlacement) blade set from the centerline." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="CoreSpacing_04B5O0qVOHuO00025QrE$V" GlobalId="04B5O0qVOHuO00025QrE$V" Name="CoreSpacing" Description="Core spacing of the profile." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="CoreTopHeight_0P2Ec0qVOHuO00025QrE$V" GlobalId="0P2Ec0qVOHuO00025QrE$V" Name="CoreTopHeight" Description="Core top height of the profile." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="CoreTopWidth_0clcy0qVOHuO00025QrE$V" GlobalId="0clcy0qVOHuO00025QrE$V" Name="CoreTopWidth" Description="Core top width of the profile." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="CoreType_0735G0qS0HuO00025QrE$V" GlobalId="0735G0qS0HuO00025QrE$V" Name="CoreType" Description="Identifies the way the core of the AirTerminal is constructed." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_AirTerminalCoreType">
						<EnumerationValues>
							<IfcLabel-wrapper>SHUTTERBLADE</IfcLabel-wrapper>
							<IfcLabel-wrapper>CURVEDBLADE</IfcLabel-wrapper>
							<IfcLabel-wrapper>REMOVABLE</IfcLabel-wrapper>
							<IfcLabel-wrapper>REVERSIBLE</IfcLabel-wrapper>
							<IfcLabel-wrapper>NONE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="CornerChamfer_2hg8a0qVGHuO00025QrE$V" GlobalId="2hg8a0qVGHuO00025QrE$V" Name="CornerChamfer" Description="The chamfer in the corners of the precast element. The chamfer is presumed to be equal in both directions." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="CornerFixingPlateFlangeWidthInPlaneX_1RkCg0qT8HuO00025QrE$V" GlobalId="1RkCg0qT8HuO00025QrE$V" Name="CornerFixingPlateFlangeWidthInPlaneX" Description="The flange width of the L-shaped corner plate in plane X." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="CornerFixingPlateFlangeWidthInPlaneZ_1MMu00qT8HuO00025QrE$V" GlobalId="1MMu00qT8HuO00025QrE$V" Name="CornerFixingPlateFlangeWidthInPlaneZ" Description="The flange width of the L-shaped corner plate in plane Z." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="CornerFixingPlateLength_1BeEi0qT8HuO00025QrE$V" GlobalId="1BeEi0qT8HuO00025QrE$V" Name="CornerFixingPlateLength" Description="The length of the L-shaped corner plate." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="CornerFixingPlateThickness_1G$ZM0qT8HuO00025QrE$V" GlobalId="1G$ZM0qT8HuO00025QrE$V" Name="CornerFixingPlateThickness" Description="The thickness of the L-shaped corner plate." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="CorrectionFactorForCooling_1Cq1a0qSuHuO00025QrE$V" GlobalId="1Cq1a0qSuHuO00025QrE$V" Name="CorrectionFactorForCooling" Description="Correction factor k as a function of water flow rate (used to calculate cooling capacity)." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="CorrectionFactorForHeating_1GOw00qSuHuO00025QrE$V" GlobalId="1GOw00qSuHuO00025QrE$V" Name="CorrectionFactorForHeating" Description="Correction factor k as a function of water flow rate (used to calculate heating capacity)." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="CorrosionTreatment_3tiPdiQHXE1RcerDmwYVRN" GlobalId="3tiPdiQHXE1RcerDmwYVRN" Name="CorrosionTreatment" Description="Determines corrosion treatment for metal components. This property is provided if the requirement needs to be expressed (a) independently of a material specification and (b) as a mere requirements statement rather than a workshop design/ processing feature." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" id="i671" Name="PEnum_ElementComponentCorrosionTreatment">
						<EnumerationValues>
							<IfcLabel-wrapper>PAINTED</IfcLabel-wrapper>
							<IfcLabel-wrapper>EPOXYCOATED</IfcLabel-wrapper>
							<IfcLabel-wrapper>GALVANISED</IfcLabel-wrapper>
							<IfcLabel-wrapper>STAINLESS</IfcLabel-wrapper>
							<IfcLabel-wrapper>POWDERCOATED</IfcLabel-wrapper>
							<IfcLabel-wrapper>GALVANIZEDANDPOWDERCOATED</IfcLabel-wrapper>
							<IfcLabel-wrapper>NONE</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTDEFINED</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="CorrosionTreatmentBolt_1xde67awL7Rh31mz_tzn8x" GlobalId="1xde67awL7Rh31mz_tzn8x" Name="CorrosionTreatmentBolt" Description="Specifies the corrosion treatment for the bolts." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i671" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="CountedEfficiency_0rK5g0qUKHuO00025QrE$V" GlobalId="0rK5g0qUKHuO00025QrE$V" Name="CountedEfficiency" Description="Filter efficiency based the particle counts concentration before and after filter against particles with certain size distribution." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="CountedEfficiencyCurve_2Q2xK0qUKHuO00025QrE$V" GlobalId="2Q2xK0qUKHuO00025QrE$V" Name="CountedEfficiencyCurve" Description="Counted efficiency curve as a function of dust holding weight, efficiency = f (dust holding weight)." TemplateType="p_tablevalue" PrimaryMeasureType="IfcMassMeasure" SecondaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="CounterSlope_2N7Ru0qVyHuO00025QrE$V" GlobalId="2N7Ru0qVyHuO00025QrE$V" Name="CounterSlope" Description="Sloping angle of the object, measured perpendicular to the slope  - relative to horizontal (0.0 degrees).
Actual maximum slope for the passageway measured perpendicular to the direction of travel according to the current design. The shape information is provided in addition to the shape representation and the geometric parameters used within. In cases of inconsistency between the geometric parameters and the shape properties, provided in the attached property, the geometric parameters take precedence.
Note: new property in IFC4." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="Country_2k46ND0cj6hhVdRs$WCmhl" GlobalId="2k46ND0cj6hhVdRs$WCmhl" Name="Country" Description="The two letter country code (from ISO 3166)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="CouplingLoss_1xcHAeM5z0ie3RUCZRUAl0" GlobalId="1xcHAeM5z0ie3RUCZRUAl0" Name="CouplingLoss" Description="Indicates the coupling loss of a leaky coaxial cable (radiating cable)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="CouplingType_1UlRO0qUOHuO00025QrE$V" GlobalId="1UlRO0qUOHuO00025QrE$V" Name="CouplingType" Description="Defines the type coupling on the inlet of the breeching inlet." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_BreechingInletCouplingType">
						<EnumerationValues>
							<IfcLabel-wrapper>INSTANTANEOUS_FEMALE</IfcLabel-wrapper>
							<IfcLabel-wrapper>INSTANTANEOUS_MALE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>USERDEFINED</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTDEFINED</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="CoverageArea_1DADu0qUSHuO00025QrE$V" GlobalId="1DADu0qUSHuO00025QrE$V" Name="CoverageArea" Description="The area that is covered by the object.

Indicates the area that the sprinkler is designed to protect." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAreaMeasure" />
				<IfcSimplePropertyTemplate id="CoverageArea_1gRAK0qWKHuO00025QrE$V" GlobalId="1gRAK0qWKHuO00025QrE$V" Name="CoverageArea" Description="The area that is covered by the object.

Floor area (typically measured as a circle whose center is at the location of the sensor)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAreaMeasure" />
				<IfcSimplePropertyTemplate id="CoveragePercentage_0zErkL8B54XBTK$nUEKqm5" GlobalId="0zErkL8B54XBTK$nUEKqm5" Name="CoveragePercentage" Description="Coverage in percentage of the mapped feature in relation to the mapped zone, e.g. tunnel face, to which it belongs." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="CoverLength_1fUae0qUeHuO00025QrE$V" GlobalId="1fUae0qUeHuO00025QrE$V" Name="CoverLength" Description="The length measured along the x-axis in the local coordinate system or the radius (in the case of a circular shape in plan) of the cover of the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="CoverLength_3DimC0qXOHuO00025QrE$V" GlobalId="3DimC0qXOHuO00025QrE$V" Name="CoverLength" Description="The length measured along the x-axis in the local coordinate system or the radius (in the case of a circular shape in plan) of the cover of the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="CoverMaterial_3VbAO0qXOHuO00025QrE$V" GlobalId="3VbAO0qXOHuO00025QrE$V" Name="CoverMaterial" Description="Material from which the cover or grating is constructed." TemplateType="p_referencevalue" PrimaryMeasureType="IfcMaterialDefinition" />
				<IfcSimplePropertyTemplate id="CoverWidth_1nqeK0qUeHuO00025QrE$V" GlobalId="1nqeK0qUeHuO00025QrE$V" Name="CoverWidth" Description="The length measured along the y-axis in the local coordinate system of the cover of the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="CoverWidth_3MezI0qXOHuO00025QrE$V" GlobalId="3MezI0qXOHuO00025QrE$V" Name="CoverWidth" Description="The length measured along the y-axis in the local coordinate system of the cover of the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="CPTConeResistance_0mLMG$dEL1XA62swey6_yV" GlobalId="0mLMG$dEL1XA62swey6_yV" Name="CPTConeResistance" Description="Cone reistance measured during the test." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="CPTconeResistance_0tVj04fSz9yvcArAhgc6n1" GlobalId="0tVj04fSz9yvcArAhgc6n1" Name="CPTconeResistance" Description="Cone penetration resistance measured during the CPT test." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="CPTLocalSideFriction_1lKAeE0kv6OwRjMM25q3Nx" GlobalId="1lKAeE0kv6OwRjMM25q3Nx" Name="CPTLocalSideFriction" Description="Sleeve friction measured during the test." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="CPTPorePressure_3oZqP_gfTF5Bo3txSCd61R" GlobalId="3oZqP_gfTF5Bo3txSCd61R" Name="CPTPorePressure" Description="Pore pressure measured during the test." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="Cracking_3j43tcg$LEXgFS1pHxFkCO" GlobalId="3j43tcg$LEXgFS1pHxFkCO" Name="Cracking" Description="Qualitative crack values estimated from drilling information." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="CrContent_0ijitX2mHAefsn6tigqyY3" GlobalId="0ijitX2mHAefsn6tigqyY3" Name="CrContent" Description="Content of Chromium. The unit must be defined in _&apos;IfcPropertySingleValue_._Unit&apos;_." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="CreationDate_3CaOJkVC194viZ6LJTu7ed" GlobalId="3CaOJkVC194viZ6LJTu7ed" Name="CreationDate" Description="Creation date of the model." TemplateType="p_singlevalue" PrimaryMeasureType="IfcDate" />
				<IfcSimplePropertyTemplate id="CreepageDistance_2gR0dwi6P8TOicDILZQqwo" GlobalId="2gR0dwi6P8TOicDILZQqwo" Name="CreepageDistance" Description="Shortest distance or the sum of the shortest distances along the surface on an insulator between two conductive parts which normally have the operating voltage between them. (IEV ref 471-01-04)" TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="Crossfall_2r4dJd_Ib7vAwA1J9WH9sP" GlobalId="2r4dJd_Ib7vAwA1J9WH9sP" Name="Crossfall" Description="Specifies the nominal crossfall as a ratio measure (slope) at the location of the event." TemplateType="p_singlevalue" PrimaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="CrossingLowerBarPitch_0vrZo0qW0HuO00025QrE$V" GlobalId="0vrZo0qW0HuO00025QrE$V" Name="CrossingLowerBarPitch" Description="The pitch length of the crossing lower bar." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="CrossingUpperBarPitch_0o5fW0qW0HuO00025QrE$V" GlobalId="0o5fW0qW0HuO00025QrE$V" Name="CrossingUpperBarPitch" Description="The pitch length of the crossing upper bar." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="CrossSectionalArea_0gEm60qSWHuO00025QrE$V" GlobalId="0gEm60qSWHuO00025QrE$V" Name="CrossSectionalArea" Description="Cross section area of the phase(s) lead(s)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAreaMeasure" />
				<IfcSimplePropertyTemplate id="CrossSectionArea_1giNG0qVOHuO00025QrE$V" GlobalId="1giNG0qVOHuO00025QrE$V" Name="CrossSectionArea" Description="Total area of the cross section (or profile) of the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAreaMeasure" />
				<IfcSimplePropertyTemplate id="CrossSectionArea_2C5h6JkUbAiuupCKgQxX5Z" GlobalId="2C5h6JkUbAiuupCKgQxX5Z" Name="CrossSectionArea" Description="The effective cross-section area of the prestressed part of the tendon." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAreaMeasure" />
				<IfcSimplePropertyTemplate id="CrossSectionShape_1z7xE0qTuHuO00025QrE$V" GlobalId="1z7xE0qTuHuO00025QrE$V" Name="CrossSectionShape" Description="Cross sectional shape. Note that this shape is uniform throughout the length of the segment. For nonuniform shapes, a transition fitting should be used instead." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_DuctSegmentShape">
						<EnumerationValues>
							<IfcLabel-wrapper>FLATOVAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>RECTANGULAR</IfcLabel-wrapper>
							<IfcLabel-wrapper>ROUND</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="CuContent_0arger_T9BI8SOL5EIy2u7" GlobalId="0arger_T9BI8SOL5EIy2u7" Name="CuContent" Description="Content of Copper. The unit must be defined in _&apos;IfcPropertySingleValue_._Unit&apos;_." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="Current_1I1maXboTEcP5x$ShYx_g0" GlobalId="1I1maXboTEcP5x$ShYx_g0" Name="Current" Description="The actual current and operable range." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="CurrentAdjustmentRange_2mlGQ0qViHuO00025QrE$V" GlobalId="2mlGQ0qViHuO00025QrE$V" Name="CurrentAdjustmentRange" Description="Upper and lower current adjustment limits for an AdjustmentValueType = RANGE. Note that this property should not have a value for an AdjustmentValueType = LIST." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="CurrentAdjustmentRangeStepValue_2uVAi0qViHuO00025QrE$V" GlobalId="2uVAi0qViHuO00025QrE$V" Name="CurrentAdjustmentRangeStepValue" Description="Step value of current adjustment for an AdjustmentValueType = RANGE. Note that this property should not have a value for an AdjustmentValueType = LIST." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="CurrentAdjustmentValues_2_Sem0qViHuO00025QrE$V" GlobalId="2_Sem0qViHuO00025QrE$V" Name="CurrentAdjustmentValues" Description="A list of current adjustment values that may be applied to a tripping unit for an AdjustmentValueType = LIST. A minimum of 1 and a maximum of 16 adjustment values may be specified. Note that this property should not have a value for an AdjustmentValueType = RANGE." TemplateType="p_listvalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="CurrentCarryingCapacity_2bRJDYSdX00x51ZO5f_6Kl" GlobalId="2bRJDYSdX00x51ZO5f_6Kl" Name="CurrentCarryingCapacity" Description="Maximum value of electric current which can be carried continuously by a conductor, a device or an apparatus, under specified conditions without its steady-state temperature exceeding a  specified value. Based on IEC60826-11-13. NOTE: The temperature specified value is maximum Design Ambient Temperature." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="CurrentContent3rdHarmonic_3g_0_IvjzCAQ60XkYRwY3f" GlobalId="3g_0_IvjzCAQ60XkYRwY3f" Name="CurrentContent3rdHarmonic" Description="The ratio between the third harmonic current and the phase current." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="CurrentForTimeDelay_3mW_u0qViHuO00025QrE$V" GlobalId="3mW_u0qViHuO00025QrE$V" Name="CurrentForTimeDelay" Description="The tripping current in [x In] at which the time delay is specified. A value for this property should only be asserted for time delay of L-function, and for I2t of the S and G function." TemplateType="p_singlevalue" PrimaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="CurrentHistory_2VhUjrajvA8eTamaxazsiB" GlobalId="2VhUjrajvA8eTamaxazsiB" Name="CurrentHistory" Description="Log of electrical current." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="CurrentRegulationRate_0hIDL7tBjFU81u978zIqML" GlobalId="0hIDL7tBjFU81u978zIqML" Name="CurrentRegulationRate" Description="It shows the ability of DC regulated power supply to suppress the fluctuation of output voltage caused by the change of load current (output current) when the input voltage is constant." TemplateType="p_singlevalue" PrimaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="CurrentRMS_0Y55X3X$b2LR4CS5G0nLXs" GlobalId="0Y55X3X$b2LR4CS5G0nLXs" Name="CurrentRMS" Description="Maximum rms (root mean square) current of an electric-electronic or electromechanical component at specified ambient temperature." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="CurrentTolerance1_1QJyW0qViHuO00025QrE$V" GlobalId="1QJyW0qViHuO00025QrE$V" Name="CurrentTolerance1" Description="The tolerance for the current of time/current-curve in [%]." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="CurrentTolerance1_1Xmg60qVeHuO00025QrE$V" GlobalId="1Xmg60qVeHuO00025QrE$V" Name="CurrentTolerance1" Description="The tolerance for the current of time/current-curve in [%]." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="CurrentTolerance1_37hoa0qVeHuO00025QrE$V" GlobalId="37hoa0qVeHuO00025QrE$V" Name="CurrentTolerance1" Description="The tolerance for the current of time/current-curve in [%]." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="CurrentTolerance2_1cr220qViHuO00025QrE$V" GlobalId="1cr220qViHuO00025QrE$V" Name="CurrentTolerance2" Description="The tolerance for the current of time/current-curve in [%] valid for times above CurrentTolereanceLimit1." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="CurrentTolerance2_1j5Sq0qVeHuO00025QrE$V" GlobalId="1j5Sq0qVeHuO00025QrE$V" Name="CurrentTolerance2" Description="The tolerance for the current of time/current-curve in [%] valid for times above CurrentTolereanceLimit1." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="CurrentTolerance2_3PaCm0qVeHuO00025QrE$V" GlobalId="3PaCm0qVeHuO00025QrE$V" Name="CurrentTolerance2" Description="The tolerance for the current of time/current-curve in [%] valid for times above CurrentTolereanceLimit1." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="CurrentToleranceLimit1_1d7_m0qVeHuO00025QrE$V" GlobalId="1d7_m0qVeHuO00025QrE$V" Name="CurrentToleranceLimit1" Description="The time limit in [s] limiting the application of CurrentTolerance1, if any. If the value is set to 0, the value of the CurrentTolerance1 is valid for the whole time/current-curve." TemplateType="p_singlevalue" PrimaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="CurrentToleranceLimit1_1VhHA0qViHuO00025QrE$V" GlobalId="1VhHA0qViHuO00025QrE$V" Name="CurrentToleranceLimit1" Description="The time limit in [s] limiting the application of CurrentTolerance1, if any. If the value is set to 0, the value of the CurrentTolerance1 is valid for the whole time/current-curve." TemplateType="p_singlevalue" PrimaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="CurrentToleranceLimit1_3G1sG0qVeHuO00025QrE$V" GlobalId="3G1sG0qVeHuO00025QrE$V" Name="CurrentToleranceLimit1" Description="The time limit in [s] limiting the application of CurrentTolerance1, if any. If the value is set to 0, the value of the CurrentTolerance1 is valid for the whole time/current-curve." TemplateType="p_singlevalue" PrimaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="CurveDesignation_0E1OU0qVqHuO00025QrE$V" GlobalId="0E1OU0qVqHuO00025QrE$V" Name="CurveDesignation" Description="The designation of the trippingcurve given by the manufacturer. For a MCB the designation should be in accordance with the designations given in IEC 60898." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="CurveDesignation_24xb20qVmHuO00025QrE$V" GlobalId="24xb20qVmHuO00025QrE$V" Name="CurveDesignation" Description="The designation of the trippingcurve given by the manufacturer. For a MCB the designation should be in accordance with the designations given in IEC 60898." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="CurveShape_3O7zTf47TB3hWv3KJi7PR5" GlobalId="3O7zTf47TB3hWv3KJi7PR5" Name="CurveShape" Description="Shape according to CurveShapeEnum" TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_CurveShapeEnum">
						<EnumerationValues>
							<IfcLabel-wrapper>INTERNAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>EXTERNAL</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="CyclicPath_2_sY8JfBfFRhE6m4raua0C" GlobalId="2_sY8JfBfFRhE6m4raua0C" Name="CyclicPath" Description="Represents the time:angle table of the kinematic behaviour." TemplateType="p_tablevalue" PrimaryMeasureType="IfcTimeMeasure" SecondaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="CyclicRange_3O_8A2txvFWP$Mo9_vRrzI" GlobalId="3O_8A2txvFWP$Mo9_vRrzI" Name="CyclicRange" Description="Identifies the angular range of the kinematic behaviour" TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="DamperControlType_3dVYS0qT4HuO00025QrE$V" GlobalId="3dVYS0qT4HuO00025QrE$V" Name="DamperControlType" Description="The type of control used to operate the damper (e.g., Open/Closed Indicator, Resettable Temperature Sensor, Temperature Override, etc.)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="DamperPosition_1TU9C0qRuHuO00025QrE$V" GlobalId="1TU9C0qRuHuO00025QrE$V" Name="DamperPosition" Description="Control damper position, ranging from 0 to 1; damper position (0=closed=90deg position angle, 1=open=0deg position angle)." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="DamperPosition_3Fycw0qT0HuO00025QrE$V" GlobalId="3Fycw0qT0HuO00025QrE$V" Name="DamperPosition" Description="Control damper position, ranging from 0 to 1; damper position (0=closed=90deg position angle, 1=open=0deg position angle)." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="DampingRatio_2PtTTcE0vEpOii8kDqjGba" GlobalId="2PtTTcE0vEpOii8kDqjGba" Name="DampingRatio" Description="Indicates the damping ratio of the device." TemplateType="p_singlevalue" PrimaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="DashedLine_3suuc1XGL608tN2w9QsDL0" GlobalId="3suuc1XGL608tN2w9QsDL0" Name="DashedLine" Description="State if the line is dashed or continuous" TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="DashedLinePattern_06qWfjkiXCOR1C_hUCX34b" GlobalId="06qWfjkiXCOR1C_hUCX34b" Name="DashedLinePattern" Description="Indicates the pattern for dashed line types e.g. &apos;3+9&apos;" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="DataCollectionType_32vg9H91z7Pu6rUIJWozFI" GlobalId="32vg9H91z7Pu6rUIJWozFI" Name="DataCollectionType" Description="Indicates the type or manner of data collection." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_DataCollectionType">
						<EnumerationValues>
							<IfcLabel-wrapper>AUTOMATICANDCONTINUOUS</IfcLabel-wrapper>
							<IfcLabel-wrapper>MANUALANDSINGLE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="DataConnectionType_2cODWDnK9A9RCBk2DE0YiP" GlobalId="2cODWDnK9A9RCBk2DE0YiP" Name="DataConnectionType" Description="Indicates the data connection type of the junction box e.g. copper pair, fiber or others." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_DataConnectionType">
						<EnumerationValues>
							<IfcLabel-wrapper>COPPER</IfcLabel-wrapper>
							<IfcLabel-wrapper>FIBER</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="DataEncryptionType_0pqbO0sVjBRR5HyenyysRl" GlobalId="0pqbO0sVjBRR5HyenyysRl" Name="DataEncryptionType" Description="Indicates the type of security protocols that can be used in the access point to protect the wireless network." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="DataExchangeRate_2AuHR1lx11mP7sIpwz9u8Z" GlobalId="2AuHR1lx11mP7sIpwz9u8Z" Name="DataExchangeRate" Description="Indicates the data transfer rate of the access point in bit per second (bps)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcIntegerCountRateMeasure" />
				<IfcSimplePropertyTemplate id="DataReceived_3dAyrzXAv2nh7ZzfP57Hvk" GlobalId="3dAyrzXAv2nh7ZzfP57Hvk" Name="DataReceived" Description="For data ports, captures log of data received.  The LIST at IfcTimeSeriesValue.Values may split out data according to Pset_DistributionPortTypeCable.Protocols." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="DataTransmissionUnitUsage_33Z4KU$Gv1RhPZvo_1CDMa" GlobalId="33Z4KU$Gv1RhPZvo_1CDMa" Name="DataTransmissionUnitUsage" Description="Indicates the usage of the data transmission unit. It can be used to transmit data for different types of sensors." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_DataTransmissionUnitUsage">
						<EnumerationValues>
							<IfcLabel-wrapper>EARTHQUAKE</IfcLabel-wrapper>
							<IfcLabel-wrapper>FOREIGNOBJECT</IfcLabel-wrapper>
							<IfcLabel-wrapper>WINDANDRAIN</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="DataTransmitted_31sBJr1t94sOktsMuxcZA2" GlobalId="31sBJr1t94sOktsMuxcZA2" Name="DataTransmitted" Description="For data ports, captures log of data transmitted. The LIST at IfcTimeSeriesValue.Values may split out data according to Pset_DistributionPortTypeCable.Protocols." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="DCResistance_1iHsZExLz0_hKDmfStAwc4" GlobalId="1iHsZExLz0_hKDmfStAwc4" Name="DCResistance" Description="The resistance under direct current and 20 degrees centigrade." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricResistanceMeasure" />
				<IfcSimplePropertyTemplate id="DeepPenetrationThroatThickness_0JLjW0qUKHuO00025QrE$V" GlobalId="0JLjW0qUKHuO00025QrE$V" Name="DeepPenetrationThroatThickness" Description="Nominal throat thickness or effective throat thickness to which a certain amount of fusion penetration is added.

&gt; REFERENCE&amp;nbsp; Symbol s according to ISO 2553:2019." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="DefinedTemperature_03IlA0qVqHuO00025QrE$V" GlobalId="03IlA0qVqHuO00025QrE$V" Name="DefinedTemperature" Description="The ambient temperature at which the thermal current/time-curve associated with this protection device is defined." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="DefinedTemperature_1eKXY0qVmHuO00025QrE$V" GlobalId="1eKXY0qVmHuO00025QrE$V" Name="DefinedTemperature" Description="The ambient temperature at which the thermal current/time-curve associated with this protection device is defined." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="DefiningElement_2ZmUzi2L1FPfWOuad7mKFO" GlobalId="2ZmUzi2L1FPfWOuad7mKFO" Name="DefiningElement" Description="Kinds of describable inhomogeneity in a rock body that may define a geologic structure. Examples include oriented particle." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="Deformability_1tVYnZVTn9oBtykLWbZYCL" GlobalId="1tVYnZVTn9oBtykLWbZYCL" Name="Deformability" Description="" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="DeformationPhase_34v8HVl7D5$hjlWFWQDfkK" GlobalId="34v8HVl7D5$hjlWFWQDfkK" Name="DeformationPhase" Description="Name or label for a geologic event such as a basin formation, compressional tectonic phase, orogeny etc." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="DefrostTemperatureEffectiveness_1iO4K0qS0HuO00025QrE$V" GlobalId="1iO4K0qS0HuO00025QrE$V" Name="DefrostTemperatureEffectiveness" Description="Temperature heat transfer effectiveness when defrosting is active." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="DegreeOfLinearity_2eBQocTLT5FgPBdrK2Bskc" GlobalId="2eBQocTLT5FgPBdrK2Bskc" Name="DegreeOfLinearity" Description="Indicates the degree of linearity of the earthquake sensor or accelerometer." TemplateType="p_singlevalue" PrimaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="DeliveryType_0fBrsqCsvBCPwzsHeQjPIh" GlobalId="0fBrsqCsvBCPwzsHeQjPIh" Name="DeliveryType" Description="Determines how the accessory will be delivered to the site." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ElementComponentDeliveryType">
						<EnumerationValues>
							<IfcLabel-wrapper>CAST_IN_PLACE</IfcLabel-wrapper>
							<IfcLabel-wrapper>WELDED_TO_STRUCTURE</IfcLabel-wrapper>
							<IfcLabel-wrapper>LOOSE</IfcLabel-wrapper>
							<IfcLabel-wrapper>ATTACHED_FOR_DELIVERY</IfcLabel-wrapper>
							<IfcLabel-wrapper>PRECAST</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTDEFINED</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Depth_0jbWAM7Tb3LB2Zw79LWTzY" GlobalId="0jbWAM7Tb3LB2Zw79LWTzY" Name="Depth" Description="The depth of the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="Depth_1ju3m0qSKHuO00025QrE$V" GlobalId="1ju3m0qSKHuO00025QrE$V" Name="Depth" Description="The requested depth or thickness of the provision for void." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="Depth_3iGzg0qTCHuO00025QrE$V" GlobalId="3iGzg0qTCHuO00025QrE$V" Name="Depth" Description="The depth of the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="DepthRange_0NQ19_ZHX2QfMh8143pjcc" GlobalId="0NQ19_ZHX2QfMh8143pjcc" Name="DepthRange" Description="Upper and bottom depth for certain geological information." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcNonNegativeLengthMeasure" />
				<IfcSimplePropertyTemplate id="DepthRange_2ZH4HxFCT21QZcxH5WymAo" GlobalId="2ZH4HxFCT21QZcxH5WymAo" Name="DepthRange" Description="The depth range where the test was performed." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcNonNegativeLengthMeasure" />
				<IfcSimplePropertyTemplate id="DerailmentHeight_1CeYfycR58Q96DOkJI5inh" GlobalId="1CeYfycR58Q96DOkJI5inh" Name="DerailmentHeight" Description="Height of derailment block when derailer in protection state." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="DerailmentMaximumSpeedLimit_1TbwEaqYL1s9iVqilDO212" GlobalId="1TbwEaqYL1s9iVqilDO212" Name="DerailmentMaximumSpeedLimit" Description="Indicates the maximum allowable train speed for the derailer." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLinearVelocityMeasure" />
				<IfcSimplePropertyTemplate id="DerailmentWheelDiameter_1gibFX8tbFXx1zQE4aQgil" GlobalId="1gibFX8tbFXx1zQE4aQgil" Name="DerailmentWheelDiameter" Description="Indicates the wheel diameter requirement for the derailer." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="DerivativeConstant_3hg4M0qSqHuO00025QrE$V" GlobalId="3hg4M0qSqHuO00025QrE$V" Name="DerivativeConstant" Description="The derivative gain factor of the controller (usually referred to as Kd). Asserted where ControlType is PROPORTIONALINTEGRALDERIVATIVE." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="Description_2W3e_0qVyHuO00025QrE$V" GlobalId="2W3e_0qVyHuO00025QrE$V" Name="Description" Description="The Description of the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="Description_3Zrq848Q59lhSMKyRwz2po" GlobalId="3Zrq848Q59lhSMKyRwz2po" Name="Description" Description="The Description of the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="DesignAirFlow_0N8C4KOqD4dhxswz_7fyAN" GlobalId="0N8C4KOqD4dhxswz_7fyAN" Name="DesignAirFlow" Description="Design air flow rate for the space." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="DesignAmbientTemperature_1L_xLZOQ911A3ajJsEJF$L" GlobalId="1L_xLZOQ911A3ajJsEJF$L" Name="DesignAmbientTemperature" Description="The highest and lowest local ambient temperature likely to be encountered." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="DesignLevel_2DT$ZBabjC$RwaWm7qB8cW" GlobalId="2DT$ZBabjC$RwaWm7qB8cW" Name="DesignLevel" Description="Adjustment of the service life resulting from the effect of design level employed." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="DesignLocationNumber_0O8uW0qVKHuO00025QrE$V" GlobalId="0O8uW0qVKHuO00025QrE$V" Name="DesignLocationNumber" Description="Defines a unique location within a structure, the ‘slot’ for which the piece was designed." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="DesignName_2vKHK0qTeHuO00025QrE$V" GlobalId="2vKHK0qTeHuO00025QrE$V" Name="DesignName" Description="A name for the design values." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="DesignSpeed_1RucFnS_DA08gMyxFgMMmy" GlobalId="1RucFnS_DA08gMyxFgMMmy" Name="DesignSpeed" Description="Speed selected in designing a new road or in modernizing, strengthening or rehabilitating an existing road section, to determine the various geometric design features of the carriageway that allow a car to travel safely at that speed, under normal road surface and weather conditions. 

&gt;NOTE&amp;nbsp; Definition according to PIARC. 
&gt;
&gt;NOTE&amp;nbsp; The design speed is not constant, but may vary depending on the conditions of relief (plain, hill, mountain)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLinearVelocityMeasure" />
				<IfcSimplePropertyTemplate id="DesignTrafficVolume_3$JqqoXBrCmxu$2E6ICdj4" GlobalId="3$JqqoXBrCmxu$2E6ICdj4" Name="DesignTrafficVolume" Description="The traffic volume used for planning and design purposes specified as the number of vehicles per day . Typically given as AADT - Average Annual Daily Traffic" TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="DesignVehicleClass_2J5aej9g10suuFcIr2MMKA" GlobalId="2J5aej9g10suuFcIr2MMKA" Name="DesignVehicleClass" Description="A vehicle designator with content according to local standards." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="DetectionRange_18tiQnmqr3a9LRMZ$sdhle" GlobalId="18tiQnmqr3a9LRMZ$sdhle" Name="DetectionRange" Description="The detection range of the equipment." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="DeterminationMethod_35EM4seR58qOdMRpSplbuQ" GlobalId="35EM4seR58qOdMRpSplbuQ" Name="DeterminationMethod" Description="Different ways to delineate the perimeter of a hazard." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="DeviceCapacity_2jcue8hCf9rP2okPzNVte5" GlobalId="2jcue8hCf9rP2okPzNVte5" Name="DeviceCapacity" Description="Mooring device force capacity" TemplateType="p_singlevalue" PrimaryMeasureType="IfcForceMeasure" />
				<IfcSimplePropertyTemplate id="DeviceType_3IIklEVDz3j9xOl8NCkENp" GlobalId="3IIklEVDz3j9xOl8NCkENp" Name="DeviceType" Description="Mooring device type" TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_MooringDeviceType">
						<EnumerationValues>
							<IfcLabel-wrapper>THEAD</IfcLabel-wrapper>
							<IfcLabel-wrapper>SINGLEBUTT</IfcLabel-wrapper>
							<IfcLabel-wrapper>DOUBLEBUTT</IfcLabel-wrapper>
							<IfcLabel-wrapper>HORN</IfcLabel-wrapper>
							<IfcLabel-wrapper>KIDNEY</IfcLabel-wrapper>
							<IfcLabel-wrapper>PILLAR</IfcLabel-wrapper>
							<IfcLabel-wrapper>CLEAT</IfcLabel-wrapper>
							<IfcLabel-wrapper>RING</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="DewateringMethod_2oFu7BguH14vxA2DX0JNDX" GlobalId="2oFu7BguH14vxA2DX0JNDX" Name="DewateringMethod" Description="Active dewatering of the ground through pumping." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_DewateringMethod">
						<EnumerationValues>
							<IfcLabel-wrapper>SUMPPUMP</IfcLabel-wrapper>
							<IfcLabel-wrapper>WELLPOINT</IfcLabel-wrapper>
							<IfcLabel-wrapper>DEEPWELL</IfcLabel-wrapper>
							<IfcLabel-wrapper>VACUUMWELLPOINTS</IfcLabel-wrapper>
							<IfcLabel-wrapper>EDUCTORWELLS</IfcLabel-wrapper>
							<IfcLabel-wrapper>USERDEFINED</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="DiagonalTrussBaseBarDiameter_1t8zM0qT8HuO00025QrE$V" GlobalId="1t8zM0qT8HuO00025QrE$V" Name="DiagonalTrussBaseBarDiameter" Description="The nominal diameter of the base bar." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="DiagonalTrussCrossBarDiameter_21tcg0qT8HuO00025QrE$V" GlobalId="21tcg0qT8HuO00025QrE$V" Name="DiagonalTrussCrossBarDiameter" Description="The nominal diameter of the diagonal cross-bars." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="DiagonalTrussCrossBarSpacing_1nnei0qT8HuO00025QrE$V" GlobalId="1nnei0qT8HuO00025QrE$V" Name="DiagonalTrussCrossBarSpacing" Description="The spacing between diagonal cross-bar sections." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="DiagonalTrussHeight_1df8o0qT8HuO00025QrE$V" GlobalId="1df8o0qT8HuO00025QrE$V" Name="DiagonalTrussHeight" Description="The overall height of the truss connector." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="DiagonalTrussLength_1j0TS0qT8HuO00025QrE$V" GlobalId="1j0TS0qT8HuO00025QrE$V" Name="DiagonalTrussLength" Description="The overall length of the truss connector." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="DiagonalTrussSecondaryBarDiameter_1yWI00qT8HuO00025QrE$V" GlobalId="1yWI00qT8HuO00025QrE$V" Name="DiagonalTrussSecondaryBarDiameter" Description="The nominal diameter of the secondary bar." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="DiagramNumber_3wqbOd6ljDowCHqDXD8raW" GlobalId="3wqbOd6ljDowCHqDXD8raW" Name="DiagramNumber" Description="A designator with content according to local standards, e.g. M25." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="Diameter_0Vw2e0qVyHuO00025QrE$V" GlobalId="0Vw2e0qVyHuO00025QrE$V" Name="Diameter" Description="The Diameter of the object.

Specifically handrail of the railing." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="Diameter_0XZt0PbcT8NePFqS$CxwYx" GlobalId="0XZt0PbcT8NePFqS$CxwYx" Name="Diameter" Description="The Diameter of the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="Diameter_1fj1w0qSKHuO00025QrE$V" GlobalId="1fj1w0qSKHuO00025QrE$V" Name="Diameter" Description="The requested diameter (in elevation) of the provision for void, only provided if the Shape property is set to &quot;round&quot;." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="Diameter_3pFWs0qX8HuO00025QrE$V" GlobalId="3pFWs0qX8HuO00025QrE$V" Name="Diameter" Description="The Diameter of the object.

For circular fins only." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="DilatationLength_32bfxZV9DAqf890UR2MfrM" GlobalId="32bfxZV9DAqf890UR2MfrM" Name="DilatationLength" Description="Length dilatation admitted by the element." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="DimensionalAccuracyClass_2akL20qSiHuO00025QrE$V" GlobalId="2akL20qSiHuO00025QrE$V" Name="DimensionalAccuracyClass" Description="Classification designation of the dimensional accuracy requirement according to local standards." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="DimensionalChangeCoefficient_1htgC0qUuHuO00025QrE$V" GlobalId="1htgC0qUuHuO00025QrE$V" Name="DimensionalChangeCoefficient" Description="Weighted dimensional change coefficient, relative to 1% change in moisture content." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="DimmerType_0HxTM0qWuHuO00025QrE$V" GlobalId="0HxTM0qWuHuO00025QrE$V" Name="DimmerType" Description="A list of the available types of dimmer switch from which that required may be selected." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" id="i798" Name="PEnum_SwitchingDeviceDimmerSwitchType">
						<EnumerationValues>
							<IfcLabel-wrapper>ROCKER</IfcLabel-wrapper>
							<IfcLabel-wrapper>SELECTOR</IfcLabel-wrapper>
							<IfcLabel-wrapper>TWIST</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="DipAngle_2AwUZOVX992eTuSYTjeerL" GlobalId="2AwUZOVX992eTuSYTjeerL" Name="DipAngle" Description="The maximum declination (dip) of the mean plane of the discontinuity from the horizontal shall be measured with the clinometer in the range 0 to 90 degrees and should be expressed in degrees as a two-digit number, e.g. 50. 
&gt;NOTE Definition according to ISO EN 14689." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="DipDirection_17WEfvK3L9Ehv8Rdn5AK_c" GlobalId="17WEfvK3L9Ehv8Rdn5AK_c" Name="DipDirection" Description="The geographic direction of a line created by the intersection of a plane and the horizontal plane. If non specific convention is used, this angular value is in the range 0 to 180 degrees. In this case, there is an ambiguity on the dip orientation. For example, a plane with an orientation of 90 degrees from the north could either have a dip direction to the North or to the South. Thus, to avoid this ambiguity, a strike value is generally completed with an indication of the dip orientation (Quadrant)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="DipDirection_2ECbWpcBD9gfOatn_dmz2$" GlobalId="2ECbWpcBD9gfOatn_dmz2$" Name="DipDirection" Description="The azimuth of the dip (dip direction) shall be measured in degrees in the range 0 to 360 degrees counted clockwise from true north. 
&gt;NOTE&amp;nbsp; Definition according to ISO EN 14689." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="Direction_3O$JC0qWGHuO00025QrE$V" GlobalId="3O$JC0qWGHuO00025QrE$V" Name="Direction" Description="Indicates sensed direction for sensors capturing magnitude and direction measured from True North (0 degrees) in a clockwise direction." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="DirectionOfRotation_2KhMi0qUCHuO00025QrE$V" GlobalId="2KhMi0qUCHuO00025QrE$V" Name="DirectionOfRotation" Description="The direction of the centrifugal fan wheel rotation when viewed from the drive side of the fan.
CLOCKWISE: Clockwise.
COUNTERCLOCKWISE: Counter-clockwise.
OTHER: Other type of fan rotation." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_CentrifugalFanRotation">
						<EnumerationValues>
							<IfcLabel-wrapper>CLOCKWISE</IfcLabel-wrapper>
							<IfcLabel-wrapper>COUNTERCLOCKWISE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="DischargeCoefficient_1u4p80qUSHuO00025QrE$V" GlobalId="1u4p80qUSHuO00025QrE$V" Name="DischargeCoefficient" Description="The coefficient of flow at the sprinkler." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="DischargeDirection_36hDO0qRyHuO00025QrE$V" GlobalId="36hDO0qRyHuO00025QrE$V" Name="DischargeDirection" Description="Discharge direction of the air terminal.
Parallel: discharges parallel to mounting surface designed so that flow attaches to the surface.
Perpendicular:  discharges away from mounting surface.
Adjustable: both parallel and perpendicular discharge." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_AirTerminalDischargeDirection">
						<EnumerationValues>
							<IfcLabel-wrapper>PARALLEL</IfcLabel-wrapper>
							<IfcLabel-wrapper>PERPENDICULAR</IfcLabel-wrapper>
							<IfcLabel-wrapper>ADJUSTABLE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="DischargeFlowRate_1im0Q0qUSHuO00025QrE$V" GlobalId="1im0Q0qUSHuO00025QrE$V" Name="DischargeFlowRate" Description="The volumetric rate of fluid discharge." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="DischargeFlowRate_2bgwk0qUOHuO00025QrE$V" GlobalId="2bgwk0qUOHuO00025QrE$V" Name="DischargeFlowRate" Description="The volumetric rate of fluid discharge." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="DischargePosition_1yrUS0qUCHuO00025QrE$V" GlobalId="1yrUS0qUCHuO00025QrE$V" Name="DischargePosition" Description="Centrifugal fan discharge position.
TOPHORIZONTAL: Top horizontal discharge.
TOPANGULARDOWN: Top angular down discharge.
DOWNBLAST: Downblast discharge.
BOTTOMANGULARDOWN: Bottom angular down discharge.
BOTTOMHORIZONTAL: Bottom horizontal discharge.
BOTTOMANGULARUP: Bottom angular up discharge.
UPBLAST: Upblast discharge.
TOPANGULARUP: Top angular up discharge.
OTHER: Other type of fan arrangement." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_CentrifugalFanDischargePosition">
						<EnumerationValues>
							<IfcLabel-wrapper>TOPHORIZONTAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>TOPANGULARDOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>TOPANGULARUP</IfcLabel-wrapper>
							<IfcLabel-wrapper>DOWNBLAST</IfcLabel-wrapper>
							<IfcLabel-wrapper>BOTTOMANGULARDOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>BOTTOMHORIZONTAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>BOTTOMANGULARUP</IfcLabel-wrapper>
							<IfcLabel-wrapper>UPBLAST</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="DischargePressureLoss_0spLC0qUGHuO00025QrE$V" GlobalId="0spLC0qUGHuO00025QrE$V" Name="DischargePressureLoss" Description="Fan discharge pressure loss associated with the discharge arrangement." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="DischargeType_2_$oY0qUCHuO00025QrE$V" GlobalId="2_$oY0qUCHuO00025QrE$V" Name="DischargeType" Description="Defines the type of connection at the fan discharge.
Duct: Discharge into ductwork.
Screen: Discharge into screen outlet.
Louver: Discharge into a louver.
Damper: Discharge into a damper." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_FanDischargeType">
						<EnumerationValues>
							<IfcLabel-wrapper>DUCT</IfcLabel-wrapper>
							<IfcLabel-wrapper>SCREEN</IfcLabel-wrapper>
							<IfcLabel-wrapper>LOUVER</IfcLabel-wrapper>
							<IfcLabel-wrapper>DAMPER</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="DischargeVelocity_0pqcA0qUGHuO00025QrE$V" GlobalId="0pqcA0qUGHuO00025QrE$V" Name="DischargeVelocity" Description="The speed at which air discharges from the fan through the fan housing discharge opening." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcLinearVelocityMeasure" />
				<IfcSimplePropertyTemplate id="DiscontinuedHeating_26m100qWmHuO00025QrE$V" GlobalId="26m100qWmHuO00025QrE$V" Name="DiscontinuedHeating" Description="Indication whether discontinued heating is required/desirable from user/designer view point. (TRUE) if yes, (FALSE) otherwise." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="DiscontinuityAperture_1$QA6RBqr9RARD6tIYf9PS" GlobalId="1$QA6RBqr9RARD6tIYf9PS" Name="DiscontinuityAperture" Description="The perpendicular distance between the two surfaces of a discontinuity is referred to as the aperture." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="DiscontinuityAperture_1TCPy13C92zPuCOEju$jod" GlobalId="1TCPy13C92zPuCOEju$jod" Name="DiscontinuityAperture" Description="The perpendicular distance between the two surfaces of a discontinuity is referred to as the aperture. 
&gt;NOTE&amp;nbsp;Definition according to ISO EN 14689." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="DiscontinuityCohesion_1f3CPfTDP4_hW9D7kdBT5b" GlobalId="1f3CPfTDP4_hW9D7kdBT5b" Name="DiscontinuityCohesion" Description="Cohesive shear strength of a rock or soil that is independent of interparticle friction." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="DiscontinuityFilling_0oNOrk83X1qOyXWFFmxs63" GlobalId="0oNOrk83X1qOyXWFFmxs63" Name="DiscontinuityFilling" Description="The infilling material between discontinuity surfaces shall be identified and described (e.g. soil,minerals such as calcite, quartz, epidote, chlorite, anhydrite, clay gouge, rock gouge or breccia)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="DiscontinuityFrictionAngle_1QIEUQzzj61QvEZL4KqYmB" GlobalId="1QIEUQzzj61QvEZL4KqYmB" Name="DiscontinuityFrictionAngle" Description="Derived from the Mohr-Coulomb failure criterion and used to describe the friction shear resistance of ground materials, together with the normal effective stress." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="DiscontinuityInFilling_2bLAkUOk95KPc7a3XyxzcW" GlobalId="2bLAkUOk95KPc7a3XyxzcW" Name="DiscontinuityInFilling" Description="The infilling material between discontinuity surfaces shall be identified and described (e.g. soil,minerals such as calcite, quartz, epidote, chlorite, anhydrite, clay gouge, rock gouge or breccia). 
&gt;NOTE&amp;nbsp;Definition according to ISO EN 14689." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="DiscontinuityPersistence_03K4NkMlL77OQrLEIDA6QX" GlobalId="03K4NkMlL77OQrLEIDA6QX" Name="DiscontinuityPersistence" Description="The linear extent of discontinuities from their inception to their termination in solid rock mass or against other discontinuities or outside the exposure shall be reported. The size of the exposure shall also be recorded. If possible and appropriate, measurements should be made in two or preferably three orthogonal directions. 
&gt;NOTE&amp;nbsp;Definition according to ISO EN 14689." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="DiscontinuityRoughness_0Hf64hl09A88FtMA190$UT" GlobalId="0Hf64hl09A88FtMA190$UT" Name="DiscontinuityRoughness" Description="The surface condition and the shape of discontinuities shall be described on the basis of three scales of observation, respectively, and using the terms given in ISO EN 14689 - Table 9 and illustrated in Figure 2: 
a) small scale (several millimetres) - smooth or rough 
b) medium scale (several centimetres) - planar, stepped or undulating 
c) large scale (several metres) - straight, curved or wavy. 

&gt;NOTE&amp;nbsp;Definition according to ISO EN 14689." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="DiscontinuitySpacing_0Ng07cMyPCy9WuDPLjdmv2" GlobalId="0Ng07cMyPCy9WuDPLjdmv2" Name="DiscontinuitySpacing" Description="The term &quot;spacing&quot; refers to the mean or modal spacing of a set of discontinuities and is the perpendicular distance between adjacent discontinuities. The number of discontinuity sets, the differences in spacing and the angles between the sets shall be reported as these determine the block shape. The discontinuity spacing should be measured in millimetres and can be classified using the terms in Table 8. 
&gt;NOTE&amp;nbsp;Definition according to ISO EN 14689." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="DiscontinuitySpacing_0VQZBIVenAlegXF1tlHC9e" GlobalId="0VQZBIVenAlegXF1tlHC9e" Name="DiscontinuitySpacing" Description="The term &quot;spacing&quot; refers to the mean or modal spacing of a set of discontinuities and is the perpendicular distance between adjacent discontinuities. The discontinuity spacing should be measured in millimetres.
&gt;NOTE Definition from ISO 14689:2017, Table 8." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_DiscontinuitySpacing">
						<EnumerationValues>
							<IfcLabel-wrapper>EXTREMELY_CLOSE</IfcLabel-wrapper>
							<IfcLabel-wrapper>VERY_CLOSE</IfcLabel-wrapper>
							<IfcLabel-wrapper>CLOSE</IfcLabel-wrapper>
							<IfcLabel-wrapper>MEDIUM</IfcLabel-wrapper>
							<IfcLabel-wrapper>WIDE</IfcLabel-wrapper>
							<IfcLabel-wrapper>VERY_WIDE</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="DiscontinuityType_1JP9rcjFXARB5hBdhk7ExF" GlobalId="1JP9rcjFXARB5hBdhk7ExF" Name="DiscontinuityType" Description="Pattern of bedding, folds, faults and discontinuities in rock masses, which subdivide the mass into individual domains or rock blocks.
&gt;NOTE&amp;nbsp; Definition according to ISO EN 14689." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="DiscontinuityWaterPresence_13x1J$ipnCAAAJyT_0MNF4" GlobalId="13x1J$ipnCAAAJyT_0MNF4" Name="DiscontinuityWaterPresence" Description="Description of estimated water inflow in excavation, to be used to define Jw(Barton), or RMR groundwater inflow rating." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="DiscontinuityWaterSeepage_37bDGHt1D5IeRZslC_HS3J" GlobalId="37bDGHt1D5IeRZslC_HS3J" Name="DiscontinuityWaterSeepage" Description="Free moisture or water flow visible at individual spots or from discontinuities." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="DishwasherType_2mhms0qTyHuO00025QrE$V" GlobalId="2mhms0qTyHuO00025QrE$V" Name="DishwasherType" Description="Type of dishwasher." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ElectricApplianceDishwasherType">
						<EnumerationValues>
							<IfcLabel-wrapper>POTWASHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>TRAYWASHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>DISHWASHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>BOTTLEWASHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>CUTLERYWASHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="DispatchingBoardType_3Uy7R9ZWXByPXF2xHimATv" GlobalId="3Uy7R9ZWXByPXF2xHimATv" Name="DispatchingBoardType" Description="Indicates the type of dispatching board." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_DispatchingBoardType">
						<EnumerationValues>
							<IfcLabel-wrapper>CENTER</IfcLabel-wrapper>
							<IfcLabel-wrapper>STATION</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Displacement_1PidMMB0X0OQe7BvinOSOP" GlobalId="1PidMMB0X0OQe7BvinOSOP" Name="Displacement" Description="Weight of water displaced by the vessel" TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassMeasure" />
				<IfcSimplePropertyTemplate id="Displacement_2JpsASSV5Cifkpo$1F70wR" GlobalId="2JpsASSV5Cifkpo$1F70wR" Name="Displacement" Description="True displacement range or total slip on the fault." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="DisplacementAccommodated_3WrFcexHH7Iur_SiiVHc94" GlobalId="3WrFcexHH7Iur_SiiVHc94" Name="DisplacementAccommodated" Description="A list of exactly three boolean values representing an accommodated displacement (value TRUE or 1) or no displacement (value FALSE or 0) on the corresponding axis where the first value represents axis X, second value axis Y and third value axis Z." TemplateType="p_listvalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="DisplayHeight_2cok60qS8HuO00025QrE$V" GlobalId="2cok60qS8HuO00025QrE$V" Name="DisplayHeight" Description="Indicates the physical height of the screen (only the display surface)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="DisplaySize_3AxEc0qUSHuO00025QrE$V" GlobalId="3AxEc0qUSHuO00025QrE$V" Name="DisplaySize" Description="The physical size of the display.

For a dial pressure gauge it will be the diameter of the dial." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="DisplaySize_3blru0qUSHuO00025QrE$V" GlobalId="3blru0qUSHuO00025QrE$V" Name="DisplaySize" Description="The physical size of the display.

In the case of a stem thermometer, this will be the length of the stem. For a dial thermometer, it will be the diameter of the dial." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="DisplayType_28PEO0qS8HuO00025QrE$V" GlobalId="28PEO0qS8HuO00025QrE$V" Name="DisplayType" Description="Indicates the type of display." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_AudioVisualDisplayType">
						<EnumerationValues>
							<IfcLabel-wrapper>CRT</IfcLabel-wrapper>
							<IfcLabel-wrapper>DLP</IfcLabel-wrapper>
							<IfcLabel-wrapper>LCD</IfcLabel-wrapper>
							<IfcLabel-wrapper>LED</IfcLabel-wrapper>
							<IfcLabel-wrapper>PLASMA</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="DisplayWidth_2WF6e0qS8HuO00025QrE$V" GlobalId="2WF6e0qS8HuO00025QrE$V" Name="DisplayWidth" Description="Indicates the physical width of the screen (only the display surface)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="DisposalLevel_2uwAVU8$D7Mfn2xkuHNa0V" GlobalId="2uwAVU8$D7Mfn2xkuHNa0V" Name="DisposalLevel" Description="Performance level at which disposal takes place" TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="DissolvedSolidsContent_0w$cu0qUuHuO00025QrE$V" GlobalId="0w$cu0qUuHuO00025QrE$V" Name="DissolvedSolidsContent" Description="Fraction of the dissolved solids to the total amount of water. This is measured in weight of dissolved solids per weight of water and is therefore unitless." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="DistanceBetweenComponentAxes_133Tm0qVKHuO00025QrE$V" GlobalId="133Tm0qVKHuO00025QrE$V" Name="DistanceBetweenComponentAxes" Description="The distance between the axes of the components, measured along the ‘South’ edge of the slab." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="DistanceBetweenParallelCircuits_2NVHp9_FL8tAeZWWe_dGTq" GlobalId="2NVHp9_FL8tAeZWWe_dGTq" Name="DistanceBetweenParallelCircuits" Description="Distance measured between parallel circuits." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="DistanceFromSurface_1GJthyvlP7KOg_1iksj$Vx" GlobalId="1GJthyvlP7KOg_1iksj$Vx" Name="DistanceFromSurface" Description="Distance from surface to start of grout body." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="DistanceFromSurface_2hh_Lii_P9XeiCvb$5SjCM" GlobalId="2hh_Lii_P9XeiCvb$5SjCM" Name="DistanceFromSurface" Description="Distance to start of grout body." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="DistanceToStopMark_3PTovWBffA9x2Weil3WJ5t" GlobalId="3PTovWBffA9x2Weil3WJ5t" Name="DistanceToStopMark" Description="Distance from the signal to the nearest stop mark at a platform." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="Diversity_2V5pS0qTeHuO00025QrE$V" GlobalId="2V5pS0qTeHuO00025QrE$V" Name="Diversity" Description="The ratio, expressed as a numerical value or as a percentage, of the simultaneous maximum demand of a group of electrical appliances or consumers within a specified period, to the sum of their individual maximum demands within the same period. The group of electrical appliances is in this case connected to this circuit. Definition from IEC 60050, IEV 691-10-04 NOTE1: It is often not desirable to size each conductor in a distribution system to support the total connected load at that point in the network. Diversity is applied on the basis of the anticipated loadings that are likely to result from all loads not being connected at the same time. NOTE2: Diversity is applied to final circuits only, not to sub-main circuits supplying other DBs." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="DownlinkRadioBand_2dhC8V9VzBAxjON4waRpK9" GlobalId="2dhC8V9VzBAxjON4waRpK9" Name="DownlinkRadioBand" Description="Indicates the frequency range, delimited by a lower frequency and an upper frequency, allocated for downlink transmission." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcFrequencyMeasure" />
				<IfcSimplePropertyTemplate id="DownstreamConnections_1FwKNmUX106g_690JTAQck" GlobalId="1FwKNmUX106g_690JTAQck" Name="DownstreamConnections" Description="Names of downstream connected equipment and spaces, if not otherwise represented" TemplateType="p_listvalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="DownstreamFloodWaterLevel_2Z_e7eAXf2IBbTY$1wtozr" GlobalId="2Z_e7eAXf2IBbTY$1wtozr" Name="DownstreamFloodWaterLevel" Description="the design minimum upstream water level for the lock complex" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="DownstreamMaintenanceWaterLevel_1S4qXKLwH6Gxj0PUEAiq1B" GlobalId="1S4qXKLwH6Gxj0PUEAiq1B" Name="DownstreamMaintenanceWaterLevel" Description="Design minimum upstream water level for the lock complex" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="DownstreamPressure_1VkWm0qXKHuO00025QrE$V" GlobalId="1VkWm0qXKHuO00025QrE$V" Name="DownstreamPressure" Description="The operating pressure of the fluid downstream of the pressure reducing valve." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="DraftBaseOffset_3VD_C0qVKHuO00025QrE$V" GlobalId="3VD_C0qVKHuO00025QrE$V" Name="DraftBaseOffset" Description="Draft base offset of the profile." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNonNegativeLengthMeasure" />
				<IfcSimplePropertyTemplate id="DraftSideOffset_3Z$9S0qVKHuO00025QrE$V" GlobalId="3Z$9S0qVKHuO00025QrE$V" Name="DraftSideOffset" Description="Draft side offset of the profile." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNonNegativeLengthMeasure" />
				<IfcSimplePropertyTemplate id="DrainConnectionSize_1b$RU0qXWHuO00025QrE$V" GlobalId="1b$RU0qXWHuO00025QrE$V" Name="DrainConnectionSize" Description="Size of the drain connection inlet to the waste disposal unit." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="DrainSize_0FXNw0qW8HuO00025QrE$V" GlobalId="0FXNw0qW8HuO00025QrE$V" Name="DrainSize" Description="The size of the drain outlet connection from the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="DrainSize_12V480qWCHuO00025QrE$V" GlobalId="12V480qWCHuO00025QrE$V" Name="DrainSize" Description="The size of the drain outlet connection from the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="DrainSize_1RqBw0qW8HuO00025QrE$V" GlobalId="1RqBw0qW8HuO00025QrE$V" Name="DrainSize" Description="The size of the drain outlet connection from the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="DrainSize_2$z880qWGHuO00025QrE$V" GlobalId="2$z880qWGHuO00025QrE$V" Name="DrainSize" Description="The size of the drain outlet connection from the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="DrainSize_2y5300qWCHuO00025QrE$V" GlobalId="2y5300qWCHuO00025QrE$V" Name="DrainSize" Description="The size of the drain outlet connection from the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="DrainSize_3uarm0qW8HuO00025QrE$V" GlobalId="3uarm0qW8HuO00025QrE$V" Name="DrainSize" Description="The size of the drain outlet connection from the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="DrillholeAngle_2Iz1Ug0hH19wbi$s8Csly$" GlobalId="2Iz1Ug0hH19wbi$s8Csly$" Name="DrillholeAngle" Description="Angle of the drillholes relative to the tunnel axis. 

&amp;gt;NOTE The angle is an absolute value and is measured in the direction of advance of the tunnel according to the figures below.

![&quot;DrillholeAngle - Overview&quot;](../../figures/ifcimprovedgroundgrouted-drillholeangle-overview.png  &quot;Figure 1 &amp;mdash; DrillholeAngle - overview.&quot;)

![&quot;DrillholeAngle - Detail&quot;](../../figures/ifcimprovedgroundgrouted-drillholeangle-detail.png &quot;Figure 2 &amp;mdash; DrillholeAngle - detail.&quot;)" TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositivePlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="DrillholeCount_2$SNxqBr14fPN2tHxaHFdx" GlobalId="2$SNxqBr14fPN2tHxaHFdx" Name="DrillholeCount" Description="Number of injection holes." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveInteger" />
				<IfcSimplePropertyTemplate id="DrillholeDiameter_0AYonBcML4YQQy0$dhvZUY" GlobalId="0AYonBcML4YQQy0$dhvZUY" Name="DrillholeDiameter" Description="Diameter of the drillhole." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="DrillholeDrifting_3$L$5j26j91P1kQ1lWGvER" GlobalId="3$L$5j26j91P1kQ1lWGvER" Name="DrillholeDrifting" Description="Drifting in relation to the drillhole length." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="DrillholeLength_1WLtByELb10O_UIdeHHVGD" GlobalId="1WLtByELb10O_UIdeHHVGD" Name="DrillholeLength" Description="Length of the drillhole." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="DrillingContractor_3Pf78hscf4NOQSyScVWVgk" GlobalId="3Pf78hscf4NOQSyScVWVgk" Name="DrillingContractor" Description="The property DrillingContractor reports the organisation responsible for drilling the borehole (as opposed to commissioning the borehole)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="DrillingDiameter_2Fc6nsWWrCKRVtXwxE__CS" GlobalId="2Fc6nsWWrCKRVtXwxE__CS" Name="DrillingDiameter" Description="Property to be removed when Pset_BoreholeConstruction is merged and DrillingDiameter from there is reused." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="DrillingDiameter_32JL8Vw$L9BhN7Dgy0bzPU" GlobalId="32JL8Vw$L9BhN7Dgy0bzPU" Name="DrillingDiameter" Description="Drilled Borehole diameter." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="DrillingMethod_2tlZTCJoP5V9xcumCFudxO" GlobalId="2tlZTCJoP5V9xcumCFudxO" Name="DrillingMethod" Description="Type of drilling method used." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="DrillOnRail_2ut2HorsvEPgzgSM02FBVT" GlobalId="2ut2HorsvEPgzgSM02FBVT" Name="DrillOnRail" Description="Indicates if the manufactured rail is drilled at its extremities or not. It can have holes on one, both or none of its extremities." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_DrillOnRail">
						<EnumerationValues>
							<IfcLabel-wrapper>ONEEND</IfcLabel-wrapper>
							<IfcLabel-wrapper>BOTHENDS</IfcLabel-wrapper>
							<IfcLabel-wrapper>NONE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="DriveConnectionType_2IfDM0qVuHuO00025QrE$V" GlobalId="2IfDM0qVuHuO00025QrE$V" Name="DriveConnectionType" Description="The way the pump drive mechanism is connected to the pump.

DIRECTDRIVE: Direct drive.
BELTDRIVE: Belt drive.
COUPLING: Coupling.
OTHER: Other type of drive connection." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_PumpDriveConnectionType">
						<EnumerationValues>
							<IfcLabel-wrapper>DIRECTDRIVE</IfcLabel-wrapper>
							<IfcLabel-wrapper>BELTDRIVE</IfcLabel-wrapper>
							<IfcLabel-wrapper>COUPLING</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="DriveInclination_3wCXCi1srD59Rj89Iug8_e" GlobalId="3wCXCi1srD59Rj89Iug8_e" Name="DriveInclination" Description="Specifies the tunnel drive inclination." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_DriveInclination">
						<EnumerationValues>
							<IfcLabel-wrapper>HORIZONTAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>VERTICAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>INCLINED</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="DrivePowerLoss_0wODe0qUGHuO00025QrE$V" GlobalId="0wODe0qUGHuO00025QrE$V" Name="DrivePowerLoss" Description="Fan drive power losses associated with the type of connection between the motor and the fan wheel." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="DryBulbTemperature_0EADBlvGD6CPPayNvIwz4O" GlobalId="0EADBlvGD6CPPayNvIwz4O" Name="DryBulbTemperature" Description="Dry bulb temperature of the object.

Indicates dry bulb temperature of the air." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="DryBulbTemperature_2$gxK0qWiHuO00025QrE$V" GlobalId="2$gxK0qWiHuO00025QrE$V" Name="DryBulbTemperature" Description="Dry bulb temperature of the object.

Loads from the dry bulb temperature." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="DryBulbTemperatureHistory_0FYdm0qWmHuO00025QrE$V" GlobalId="0FYdm0qWmHuO00025QrE$V" Name="DryBulbTemperatureHistory" Description="Loads from the dry bulb temperature." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="DryBulkDensity_0nEw_cmQP96hsnDkHk7anm" GlobalId="0nEw_cmQP96hsnDkHk7anm" Name="DryBulkDensity" Description="Ratio of the mass of the solid to the unit total volume (dry material)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassDensityMeasure" />
				<IfcSimplePropertyTemplate id="DryBulkDensity_2Zd$lo7FL9eP39_zTeDr$R" GlobalId="2Zd$lo7FL9eP39_zTeDr$R" Name="DryBulkDensity" Description="Ratio of the mass of solid to the unit total volume (dry material)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassDensityMeasure" />
				<IfcSimplePropertyTemplate id="DualDeck_36ri40qXCHuO00025QrE$V" GlobalId="36ri40qXCHuO00025QrE$V" Name="DualDeck" Description="Does the AirHandler have a dual deck? TRUE = Yes, FALSE = No." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="DuctSealant_3YSQM0qTeHuO00025QrE$V" GlobalId="3YSQM0qTeHuO00025QrE$V" Name="DuctSealant" Description="Type of sealant used on the duct and fittings." TemplateType="p_referencevalue" PrimaryMeasureType="IfcMaterialDefinition" />
				<IfcSimplePropertyTemplate id="DuctSizingMethod_2$tuo0qTeHuO00025QrE$V" GlobalId="2$tuo0qTeHuO00025QrE$V" Name="DuctSizingMethod" Description="Enumeration that identifies the methodology to be used to size system components." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_DuctSizingMethod">
						<EnumerationValues>
							<IfcLabel-wrapper>CONSTANTFRICTION</IfcLabel-wrapper>
							<IfcLabel-wrapper>CONSTANTPRESSURE</IfcLabel-wrapper>
							<IfcLabel-wrapper>STATICREGAIN</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="DumpCategory_0YD7LOfxzCLBoIp$XLTV09" GlobalId="0YD7LOfxzCLBoIp$XLTV09" Name="DumpCategory" Description="Project-related category for re-use and storage of the excavated material." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="DurabilityRating_3DuTq0qTiHuO00025QrE$V" GlobalId="3DuTq0qTiHuO00025QrE$V" Name="DurabilityRating" Description="Durability against mechanical stress. It is given according to the national code or regulation." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="Duration_209vs0qVWHuO00025QrE$V" GlobalId="209vs0qVWHuO00025QrE$V" Name="Duration" Description="Duration.

The period of time for the lease." TemplateType="p_singlevalue" PrimaryMeasureType="IfcDuration" />
				<IfcSimplePropertyTemplate id="Duration_2rj9qW2$99f9rLZEzwotMz" GlobalId="2rj9qW2$99f9rLZEzwotMz" Name="Duration" Description="Duration.

Duration of process." TemplateType="p_singlevalue" PrimaryMeasureType="IfcDuration" />
				<IfcSimplePropertyTemplate id="DurationDisposalLevel_16JK8wyPLDO8Mk8M9dZ9GE" GlobalId="16JK8wyPLDO8Mk8M9dZ9GE" Name="DurationDisposalLevel" Description="Duration interval at which disposal is performed" TemplateType="p_singlevalue" PrimaryMeasureType="IfcDuration" />
				<IfcSimplePropertyTemplate id="DurationMaintenanceLevel_1gQdA$yNX0POemNRUyqM7I" GlobalId="1gQdA$yNX0POemNRUyqM7I" Name="DurationMaintenanceLevel" Description="Duration interval at which maintenance is performed" TemplateType="p_singlevalue" PrimaryMeasureType="IfcDuration" />
				<IfcSimplePropertyTemplate id="DurationReplacementLevel_3RZbfgMY10_e7CpEeGzIIB" GlobalId="3RZbfgMY10_e7CpEeGzIIB" Name="DurationReplacementLevel" Description="Duration interval at which replacement is performed" TemplateType="p_singlevalue" PrimaryMeasureType="IfcDuration" />
				<IfcSimplePropertyTemplate id="DurationTargetPerformance_2Y0uegcZf7RAvwBrRwhGyj" GlobalId="2Y0uegcZf7RAvwBrRwhGyj" Name="DurationTargetPerformance" Description="Target time to failure of the asset" TemplateType="p_singlevalue" PrimaryMeasureType="IfcDuration" />
				<IfcSimplePropertyTemplate id="DustHoldingCapacity_1qVgk0qUKHuO00025QrE$V" GlobalId="1qVgk0qUKHuO00025QrE$V" Name="DustHoldingCapacity" Description="Maximum filter dust holding capacity." TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassMeasure" />
				<IfcSimplePropertyTemplate id="DynamicLoad_1mwsvedSD15w8oYBVVJ6aM" GlobalId="1mwsvedSD15w8oYBVVJ6aM" Name="DynamicLoad" Description="The dynamic load on the shell construction when the fan is in operation." TemplateType="p_singlevalue" PrimaryMeasureType="IfcForceMeasure" />
				<IfcSimplePropertyTemplate id="DynamicRange_1_5uyUpJHENuvUg5DlNq32" GlobalId="1_5uyUpJHENuvUg5DlNq32" Name="DynamicRange" Description="Indicates the dynamic range of the sensor." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcLinearVelocityMeasure" />
				<IfcSimplePropertyTemplate id="DynamicViscosity_1sJ6q0qUqHuO00025QrE$V" GlobalId="1sJ6q0qUqHuO00025QrE$V" Name="DynamicViscosity" Description="A measure of the viscous resistance of the material." TemplateType="p_singlevalue" PrimaryMeasureType="IfcDynamicViscosityMeasure" />
				<IfcSimplePropertyTemplate id="EarlyStrengthDevelopment_0xMZaUlN5EQRS7ruLVPHrd" GlobalId="0xMZaUlN5EQRS7ruLVPHrd" Name="EarlyStrengthDevelopment" Description="Class of energy absorption according to EN 14487-1

This is strongly dependent on the place of application of the sprayed concrete or mortar where different requirements for early strength development must be met" TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_EarlyStrengthDevelopment">
						<EnumerationValues>
							<IfcLabel-wrapper>J1</IfcLabel-wrapper>
							<IfcLabel-wrapper>J2</IfcLabel-wrapper>
							<IfcLabel-wrapper>J3</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="EarthFailureDeviceType_3GLIw0qVqHuO00025QrE$V" GlobalId="3GLIw0qVqHuO00025QrE$V" Name="EarthFailureDeviceType" Description="A list of the available types of circuit breaker from which that required may be selected where:

Standard: Device that operates without a time delay.
TimeDelayed: Device that operates after a time delay." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_EarthFailureDeviceType">
						<EnumerationValues>
							<IfcLabel-wrapper>STANDARD</IfcLabel-wrapper>
							<IfcLabel-wrapper>TIMEDELAYED</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="EarthFault1PoleMaximumState_2DqIa0qU0HuO00025QrE$V" GlobalId="2DqIa0qU0HuO00025QrE$V" Name="EarthFault1PoleMaximumState" Description="Maximum 1 pole earth fault current provided at the point of supply i.e. the fault between 1 phase and PE/PEN." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="EarthFault1PoleMinimumState_2NyoU0qU0HuO00025QrE$V" GlobalId="2NyoU0qU0HuO00025QrE$V" Name="EarthFault1PoleMinimumState" Description="Minimum 1 pole earth fault current provided at the point of supply i.e. the fault between 1 phase and PE/PEN." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="EarthFault1PolePowerFactorMaximumState_2JBdE0qU0HuO00025QrE$V" GlobalId="2JBdE0qU0HuO00025QrE$V" Name="EarthFault1PolePowerFactorMaximumState" Description="Power factor of the maximum 1 pole earth fault current provided at the point of supply i.e. the fault between 1 phase and PE/PEN." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="EarthFault1PolePowerFactorMinimumState_2TK780qU0HuO00025QrE$V" GlobalId="2TK780qU0HuO00025QrE$V" Name="EarthFault1PolePowerFactorMinimumState" Description="Power factor of the minimum 1 pole earth fault current provided at the point of supply i.e. the fault between 1 phase and PE/PEN." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="EarthingStyle_31GzGB0Kz6DfNA40OdlMGX" GlobalId="31GzGB0Kz6DfNA40OdlMGX" Name="EarthingStyle" Description="Indicates the earthing style of the electric device." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="EarthquakeSensorRange_3IBX9s4kz9agU5ycgPD6BR" GlobalId="3IBX9s4kz9agU5ycgPD6BR" Name="EarthquakeSensorRange" Description="Indicates the measuring range of the earthquake sensor or accelerometer." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcLinearVelocityMeasure" />
				<IfcSimplePropertyTemplate id="EarthquakeSensorType_3flYriVcrCHh7jxmFTBNc_" GlobalId="3flYriVcrCHh7jxmFTBNc_" Name="EarthquakeSensorType" Description="Indicates the type of earthquake sensor or accelerometer." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_EarthquakeSensorType">
						<EnumerationValues>
							<IfcLabel-wrapper>2DIRECTION</IfcLabel-wrapper>
							<IfcLabel-wrapper>3DIRECTION</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="EarthworksCutExcavationMethod_1dC1DQjIXA4x0mhFKgM7b6" GlobalId="1dC1DQjIXA4x0mhFKgM7b6" Name="EarthworksCutExcavationMethod" Description="Method of excavation." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_EarthworksCutExcavationMethod">
						<EnumerationValues>
							<IfcLabel-wrapper>HAND</IfcLabel-wrapper>
							<IfcLabel-wrapper>EXCAVATOR</IfcLabel-wrapper>
							<IfcLabel-wrapper>JACKHAMMER</IfcLabel-wrapper>
							<IfcLabel-wrapper>RIPPER</IfcLabel-wrapper>
							<IfcLabel-wrapper>DRILLANDBLAST</IfcLabel-wrapper>
							<IfcLabel-wrapper>USERDEFINED</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="EccentricityInY_0sGv0_Fz15KQ5d5v6ZqgOf" GlobalId="0sGv0_Fz15KQ5d5v6ZqgOf" Name="EccentricityInY" Description="Distance in y direction between the two points (or vertex points) engaged in the point connection." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="EccentricityInZ_1bzSQEjR99Xf_xfCOD1h$R" GlobalId="1bzSQEjR99Xf_xfCOD1h$R" Name="EccentricityInZ" Description="Distance in z direction between the two points (or vertex points) engaged in the point connection." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="EdgeDistanceToFirstAxis_0yVsI0qVKHuO00025QrE$V" GlobalId="0yVsI0qVKHuO00025QrE$V" Name="EdgeDistanceToFirstAxis" Description="The distance from the left (‘West’) edge of the slab (in the direction of span of the components) to the axis of the first component." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="EdgeDraft_3QSoy0qVKHuO00025QrE$V" GlobalId="3QSoy0qVKHuO00025QrE$V" Name="EdgeDraft" Description="Edge draft of the profile." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNonNegativeLengthMeasure" />
				<IfcSimplePropertyTemplate id="EdgeFixingPlateFlangeWidthInPlaneX_2TINM0qT8HuO00025QrE$V" GlobalId="2TINM0qT8HuO00025QrE$V" Name="EdgeFixingPlateFlangeWidthInPlaneX" Description="The flange width of the L-shaped edge plate in plane X." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="EdgeFixingPlateFlangeWidthInPlaneZ_2Nx2i0qT8HuO00025QrE$V" GlobalId="2Nx2i0qT8HuO00025QrE$V" Name="EdgeFixingPlateFlangeWidthInPlaneZ" Description="The flange width of the L-shaped edge plate in plane Z." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="EdgeFixingPlateLength_2DCPO0qT8HuO00025QrE$V" GlobalId="2DCPO0qT8HuO00025QrE$V" Name="EdgeFixingPlateLength" Description="The length of the L-shaped edge plate." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="EdgeFixingPlateThickness_2IZk20qT8HuO00025QrE$V" GlobalId="2IZk20qT8HuO00025QrE$V" Name="EdgeFixingPlateThickness" Description="The thickness of the L-shaped edge plate." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="EffectiveArea_19pYm0qS0HuO00025QrE$V" GlobalId="19pYm0qS0HuO00025QrE$V" Name="EffectiveArea" Description="Effective discharge area of the air terminal." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAreaMeasure" />
				<IfcSimplePropertyTemplate id="EffectiveCapacity_0AnyS0qX0HuO00025QrE$V" GlobalId="0AnyS0qX0HuO00025QrE$V" Name="EffectiveCapacity" Description="The total effective or actual volumetric capacity of the tank." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumeMeasure" />
				<IfcSimplePropertyTemplate id="EffectiveChamberSize_0Pt2rrz9f1d9B7W_YtzB4B" GlobalId="0Pt2rrz9f1d9B7W_YtzB4B" Name="EffectiveChamberSize" Description="Volumetric measure defining the effective chamber size for operational and design activities." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumeMeasure" />
				<IfcSimplePropertyTemplate id="Effectiveness_1SMLq0qU8HuO00025QrE$V" GlobalId="1SMLq0qU8HuO00025QrE$V" Name="Effectiveness" Description="Effectiveness, represented as ratio.

Ratio of the change in dry bulb temperature of the (primary) air stream to the difference between the entering dry bulb temperature of the (primary) air and the wet-bulb temperature of the (secondary) air." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="Effectiveness_2Wh2E0qWaHuO00025QrE$V" GlobalId="2Wh2E0qWaHuO00025QrE$V" Name="Effectiveness" Description="Effectiveness, represented as ratio.

Ratio of the real heat transfer rate to the maximum possible heat transfer rate." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="EffectivenessTable_2dSt00qU8HuO00025QrE$V" GlobalId="2dSt00qU8HuO00025QrE$V" Name="EffectivenessTable" Description="Total heat transfer effectiveness curve as a function of the primary air flow rate." TemplateType="p_tablevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" SecondaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="EffectiveThrust_1ekGiZJAP4nBsEk83RlhQT" GlobalId="1ekGiZJAP4nBsEk83RlhQT" Name="EffectiveThrust" Description="The effective thrust of the fan." TemplateType="p_singlevalue" PrimaryMeasureType="IfcForceMeasure" />
				<IfcSimplePropertyTemplate id="EfficiencyCurve_2oBmI0qUGHuO00025QrE$V" GlobalId="2oBmI0qUGHuO00025QrE$V" Name="EfficiencyCurve" Description="Fan efficiency =f (flow rate)." TemplateType="p_tablevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" SecondaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="EfficiencyPoint_2cbW2T9CPEk9B$EXGpp6o5" GlobalId="2cbW2T9CPEk9B$EXGpp6o5" Name="EfficiencyPoint" Description="The point at which the fan operates, e.g. 0.5." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="ElectricActuatorType_1UzOk0qRqHuO00025QrE$V" GlobalId="1UzOk0qRqHuO00025QrE$V" Name="ElectricActuatorType" Description="Enumeration that identifies electric actuator as defined by its operational principle." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ElectricActuatorType">
						<EnumerationValues>
							<IfcLabel-wrapper>MOTORDRIVE</IfcLabel-wrapper>
							<IfcLabel-wrapper>MAGNETIC</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ElectricalClearance_3Ccusqm3PAbetmCrKaebrB" GlobalId="3Ccusqm3PAbetmCrKaebrB" Name="ElectricalClearance" Description="The recommended air clearances between earth and the live parts of the overhead contactline system." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ElectricalClearanceDistance_3by6kXTBP1n8YEJ6ADRLhV" GlobalId="3by6kXTBP1n8YEJ6ADRLhV" Name="ElectricalClearanceDistance" Description="The distance between two conductive parts along a string stretched the shortest way between these conductive parts. (IEV ref 441-17-31)" TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ElectricalConductivity_0JOFocHPD1Rxfnqm5NX9ca" GlobalId="0JOFocHPD1Rxfnqm5NX9ca" Name="ElectricalConductivity" Description="Electrical conductivity. Measured under specified conditions, between the opposite faces of a unit cube of defined dimensions of an aqueous solution. For water quality examination, this is often expressed as &quot;electrical conductivity&quot; and may be used as a measure of the concentration of ionizable solutes present in the sample." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricConductanceMeasure" />
				<IfcSimplePropertyTemplate id="ElectricalConnectionType_0RKQL3FvDFfwK378TxjBGf" GlobalId="0RKQL3FvDFfwK378TxjBGf" Name="ElectricalConnectionType" Description="The physical port connection:

ACPLUG: AC plug DCPLUG: DC plug CRIMP: bare wire" TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_DistributionPortElectricalType">
						<EnumerationValues>
							<IfcLabel-wrapper>ACPLUG</IfcLabel-wrapper>
							<IfcLabel-wrapper>DCPLUG</IfcLabel-wrapper>
							<IfcLabel-wrapper>COAXIAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>CRIMP</IfcLabel-wrapper>
							<IfcLabel-wrapper>RJ</IfcLabel-wrapper>
							<IfcLabel-wrapper>RADIO</IfcLabel-wrapper>
							<IfcLabel-wrapper>DIN</IfcLabel-wrapper>
							<IfcLabel-wrapper>DSUB</IfcLabel-wrapper>
							<IfcLabel-wrapper>DVI</IfcLabel-wrapper>
							<IfcLabel-wrapper>EIAJ</IfcLabel-wrapper>
							<IfcLabel-wrapper>HDMI</IfcLabel-wrapper>
							<IfcLabel-wrapper>RCA</IfcLabel-wrapper>
							<IfcLabel-wrapper>SOCKET</IfcLabel-wrapper>
							<IfcLabel-wrapper>TRS</IfcLabel-wrapper>
							<IfcLabel-wrapper>USB</IfcLabel-wrapper>
							<IfcLabel-wrapper>XLR</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ElectricalCrossCapacity_0quq4gG9n9tv6gtXkQaQ$F" GlobalId="0quq4gG9n9tv6gtXkQaQ$F" Name="ElectricalCrossCapacity" Description="Indicates the electrical cross capacity of the transport equipment." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ElectricalFeederType_35eHZrPkfE3fcLpjm1KsIK" GlobalId="35eHZrPkfE3fcLpjm1KsIK" Name="ElectricalFeederType" Description="Type of electrical feeder." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ElectricalFeederType">
						<EnumerationValues>
							<IfcLabel-wrapper>ALONGTRACKFEEDER</IfcLabel-wrapper>
							<IfcLabel-wrapper>BYPASSFEEDER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NEGATIVEFEEDER</IfcLabel-wrapper>
							<IfcLabel-wrapper>POSITIVEFEEDER</IfcLabel-wrapper>
							<IfcLabel-wrapper>REINFORCINGFEEDER</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ElectricalSystemCategory_2GoHi0qTeHuO00025QrE$V" GlobalId="2GoHi0qTeHuO00025QrE$V" Name="ElectricalSystemCategory" Description="Designates the voltage range of the circuit, according to IEC.  HIGHVOLTAGE indicates &gt;1000V AC or &gt;1500V DV; LOWVOLTAGE indicates 50-1000V AC or 120-1500V DC; EXTRALOWVOLTAGE indicates &lt;50V AC or &lt;120V DC." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_DistributionSystemElectricalCategory">
						<EnumerationValues>
							<IfcLabel-wrapper>HIGHVOLTAGE</IfcLabel-wrapper>
							<IfcLabel-wrapper>LOWVOLTAGE</IfcLabel-wrapper>
							<IfcLabel-wrapper>EXTRALOWVOLTAGE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ElectricalSystemType_206AK0qTeHuO00025QrE$V" GlobalId="206AK0qTeHuO00025QrE$V" Name="ElectricalSystemType" Description="For certain purposes of electrical regulations, IEC 60364 defines types of system using type identifiers. Assignment of identifiers depends upon the relationship of the source, and of exposed conductive parts of the installation, to Ground (Earth).   Identifiers that may be assigned through IEC 60364 are:

•TN type system, a system having one or more points of the source of energy directly earthed, the exposed conductive parts of the installation being connected to that point by protective conductors,
•TN C type system, a TN type system in which neutral and protective functions are combined in a single conductor throughout the system,
•TN S type system, a TN type system having separate neutral and protective conductors throughout the system,
•TN C S type system, a TN type system in which neutral and protective functions are combined in a single conductor in part of the system,
•TT type system, a system having one point of the source of energy directly earthed, the exposed conductive parts of the installation being connected to earth electrodes electrically independent of the earth electrodes of the source,
•IT type system, a system having no direct connection between live parts and Earth, the exposed conductive parts of the electrical installation being earthed." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_DistributionSystemElectricalType">
						<EnumerationValues>
							<IfcLabel-wrapper>TN</IfcLabel-wrapper>
							<IfcLabel-wrapper>TN_C</IfcLabel-wrapper>
							<IfcLabel-wrapper>TN_S</IfcLabel-wrapper>
							<IfcLabel-wrapper>TN_C_S</IfcLabel-wrapper>
							<IfcLabel-wrapper>TT</IfcLabel-wrapper>
							<IfcLabel-wrapper>IT</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ElectricCookerType_3BWO80qTyHuO00025QrE$V" GlobalId="3BWO80qTyHuO00025QrE$V" Name="ElectricCookerType" Description="Type of electric cooker." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ElectricApplianceElectricCookerType">
						<EnumerationValues>
							<IfcLabel-wrapper>STEAMCOOKER</IfcLabel-wrapper>
							<IfcLabel-wrapper>DEEPFRYER</IfcLabel-wrapper>
							<IfcLabel-wrapper>STOVE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OVEN</IfcLabel-wrapper>
							<IfcLabel-wrapper>TILTINGFRYINGPAN</IfcLabel-wrapper>
							<IfcLabel-wrapper>COOKINGKETTLE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ElectricGeneratorEfficiency_2x7TS0qU0HuO00025QrE$V" GlobalId="2x7TS0qU0HuO00025QrE$V" Name="ElectricGeneratorEfficiency" Description="The ratio of output capacity to intake capacity." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="Electricity_3nmHK0qXCHuO00025QrE$V" GlobalId="3nmHK0qXCHuO00025QrE$V" Name="Electricity" Description="The amount of electricity consumed during the period specified in the time series." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcEnergyMeasure" />
				<IfcSimplePropertyTemplate id="ElectricMotorEfficiency_3fcx80qU0HuO00025QrE$V" GlobalId="3fcx80qU0HuO00025QrE$V" Name="ElectricMotorEfficiency" Description="The ratio of output capacity to intake capacity." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="ElectrificationType_1_UrHKqNv3$w5LVrIbepR6" GlobalId="1_UrHKqNv3$w5LVrIbepR6" Name="ElectrificationType" Description="Indicates the type of railway electrification." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ElectrificationType">
						<EnumerationValues>
							<IfcLabel-wrapper>NON_ELECTRIFIED</IfcLabel-wrapper>
							<IfcLabel-wrapper>AC</IfcLabel-wrapper>
							<IfcLabel-wrapper>DC</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ElectroMagneticStandardsCompliance_2waDzwzkPEmfBnDmVCqDVK" GlobalId="2waDzwzkPEmfBnDmVCqDVK" Name="ElectroMagneticStandardsCompliance" Description="Information about compliance with regard to electro magnetic related standards." TemplateType="p_tablevalue" PrimaryMeasureType="IfcLabel" SecondaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="ElectroMagneticTrippingUnitType_15l$_0qVmHuO00025QrE$V" GlobalId="15l$_0qVmHuO00025QrE$V" Name="ElectroMagneticTrippingUnitType" Description="A list of the available types of electric magnetic tripping unit from which that required may be selected. These cover overload, none special, short circuit, motor protection and bi-metal tripping." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ElectroMagneticTrippingUnitType">
						<EnumerationValues>
							<IfcLabel-wrapper>OL</IfcLabel-wrapper>
							<IfcLabel-wrapper>TMP_STD</IfcLabel-wrapper>
							<IfcLabel-wrapper>TMP_SC</IfcLabel-wrapper>
							<IfcLabel-wrapper>TMP_MP</IfcLabel-wrapper>
							<IfcLabel-wrapper>TMP_BM</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ElectronicFilterType_1CfK$TChb3WvEVYC2jfIpk" GlobalId="1CfK$TChb3WvEVYC2jfIpk" Name="ElectronicFilterType" Description="Type of electronic filter." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ElectronicFilterType">
						<EnumerationValues>
							<IfcLabel-wrapper>LOWPASSFILTER</IfcLabel-wrapper>
							<IfcLabel-wrapper>HIGHPASSFILTER</IfcLabel-wrapper>
							<IfcLabel-wrapper>BANDPASSFLITER</IfcLabel-wrapper>
							<IfcLabel-wrapper>BANDSTOPFILTER</IfcLabel-wrapper>
							<IfcLabel-wrapper>HARMONICFILTER</IfcLabel-wrapper>
							<IfcLabel-wrapper>FILTERCAPACITOR</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ElectronicMailAddresses_1Fb2vEv$TEW9HBS3QLXfbY" GlobalId="1Fb2vEv$TEW9HBS3QLXfbY" Name="ElectronicMailAddresses" Description="The list of Email addresses at which Email messages may be received." TemplateType="p_listvalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ElectronicTrippingUnitType_2IezO0qVmHuO00025QrE$V" GlobalId="2IezO0qVmHuO00025QrE$V" Name="ElectronicTrippingUnitType" Description="A list of the available types of electronic tripping unit from which that required may be selected." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ElectronicTrippingUnitType">
						<EnumerationValues>
							<IfcLabel-wrapper>EP_BM</IfcLabel-wrapper>
							<IfcLabel-wrapper>EP_MP</IfcLabel-wrapper>
							<IfcLabel-wrapper>EP_SC</IfcLabel-wrapper>
							<IfcLabel-wrapper>EP_STD</IfcLabel-wrapper>
							<IfcLabel-wrapper>EP_TIMEDELAYED</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Elevation_2CNMMPOkjA69oPOt9bGTaw" GlobalId="2CNMMPOkjA69oPOt9bGTaw" Name="Elevation" Description="Elevation of the entity" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="Elevation_2IUsNzp9b5HxiNZd7EdtMT" GlobalId="2IUsNzp9b5HxiNZd7EdtMT" Name="Elevation" Description="This property provides the numeric value of the (absolute) elevation of the groundwater surface (defined in the property SurfaceType)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="ElevationalFlatness_14HXFGUPn1GRTDa16b37bZ" GlobalId="14HXFGUPn1GRTDa16b37bZ" Name="ElevationalFlatness" Description="Indicative (95%-100%) range flatness associated to the elevational surface in ZX, if different to the overall flatness." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ElevationOfFFLRelative_3p$gHe8S590Q5xZmxUuMwH" GlobalId="3p$gHe8S590Q5xZmxUuMwH" Name="ElevationOfFFLRelative" Description="Elevation of the top surface of the finished floor level given in elevation above the local zero height. If the level varies and there is no significantly more prominent elevation, then this property may be omitted. In case of any inconsistency with the geometric positioning of the top surface, the geometric representation takes precedence." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="ElevationOfRefHeight_2NCeO6qW97WvcuUYvV8Wxf" GlobalId="2NCeO6qW97WvcuUYvV8Wxf" Name="ElevationOfRefHeight" Description="Elevation above sea level of the reference height used for all storey elevation measures, equals to height 0.0. It is usually the ground floor level." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="ElevationOfSSLRelative_3x5PSsV1TCdAdeFviYo34j" GlobalId="3x5PSsV1TCdAdeFviYo34j" Name="ElevationOfSSLRelative" Description="Elevation of the top surface of the structural slab level given in elevation above the local zero height. If the level varies and there is no significantly more prominent elevation, then this property may be omitted. In case of any inconsistency with the geometric positioning of the top surface, the geometric representation takes precedence." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="ElevationOfTerrain_0XCfx2I4T8YQefsZ57NzAZ" GlobalId="0XCfx2I4T8YQefsZ57NzAZ" Name="ElevationOfTerrain" Description="Elevation above the minimal terrain level around the foot print of the building, given in elevation above sea level." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="Enabled_3g9520qS0HuO00025QrE$V" GlobalId="3g9520qS0HuO00025QrE$V" Name="Enabled" Description="Indicates whether alarm is enabled or disabled over time." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="EncapsulationTechnologyCode_17B_9r6_5FWwAMTe_Dht3b" GlobalId="17B_9r6_5FWwAMTe_Dht3b" Name="EncapsulationTechnologyCode" Description="Code indicating the encapsulation technology which has been applied in an electric, electronic or electromechanical component." TemplateType="p_singlevalue" PrimaryMeasureType="IfcIdentifier" />
				<IfcSimplePropertyTemplate id="EndDate_1fVaW0qV8HuO00025QrE$V" GlobalId="1fVaW0qV8HuO00025QrE$V" Name="EndDate" Description="Date and time at which the permit ceases to be valid." TemplateType="p_singlevalue" PrimaryMeasureType="IfcDateTime" />
				<IfcSimplePropertyTemplate id="EndElevation_3OTOsjYu9DUAR5D1hN5Xdg" GlobalId="3OTOsjYu9DUAR5D1hN5Xdg" Name="EndElevation" Description="Elevation of the end point relative to the mean sea level." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="EndShapeType_0V2yG0qX0HuO00025QrE$V" GlobalId="0V2yG0qX0HuO00025QrE$V" Name="EndShapeType" Description="Defines the types of end shapes that can be used for preformed tanks. The convention for reading these enumerated values is that for a vertical cylinder, the first value is the base and the second is the top; for a horizontal cylinder, the order of reading should be left to right. For a speherical tank, the value UNSET should be used." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" id="i975" Name="PEnum_EndShapeType">
						<EnumerationValues>
							<IfcLabel-wrapper>CONCAVECONVEX</IfcLabel-wrapper>
							<IfcLabel-wrapper>FLATCONVEX</IfcLabel-wrapper>
							<IfcLabel-wrapper>CONVEXCONVEX</IfcLabel-wrapper>
							<IfcLabel-wrapper>CONCAVEFLAT</IfcLabel-wrapper>
							<IfcLabel-wrapper>FLATFLAT</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="EndShapeType_1uS$C0qX0HuO00025QrE$V" GlobalId="1uS$C0qX0HuO00025QrE$V" Name="EndShapeType" Description="Defines the types of end shapes that can be used for preformed tanks. The convention for reading these enumerated values is that for a vertical cylinder, the first value is the base and the second is the top; for a horizontal cylinder, the order of reading should be left to right. For a speherical tank, the value UNSET should be used." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i975" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="EndSmoothingLength_2EtJ89wAfDgPQfnCNoxkN6" GlobalId="2EtJ89wAfDgPQfnCNoxkN6" Name="EndSmoothingLength" Description="Length for the circular transition change of curvature at the end of the cant segment, measured from the start of the circular transition change of curvature to the end of the cant segment." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="EnergyAbsorption_3cEXeuXEPEEBpQYb23aZbV" GlobalId="3cEXeuXEPEEBpQYb23aZbV" Name="EnergyAbsorption" Description="Energy absorption capacity of the element." TemplateType="p_singlevalue" PrimaryMeasureType="IfcEnergyMeasure" />
				<IfcSimplePropertyTemplate id="EnergyAbsorptionTolerance_1OJ17ugQX03Bd4SHIow6m5" GlobalId="1OJ17ugQX03Bd4SHIow6m5" Name="EnergyAbsorptionTolerance" Description="Manufacturing tolerance on energy absorption" TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="EnergyAbsportionCapacity28d_3UejlFN5n7GRaO5BEtDnYA" GlobalId="3UejlFN5n7GRaO5BEtDnYA" Name="EnergyAbsportionCapacity28d" Description="Energy absorption capacity after 28 days according EN 14488-5 standard (only for fibre concrete)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcEnergyMeasure" />
				<IfcSimplePropertyTemplate id="EnergyAbsportionCapacity7d_07C5C3$vz6oRj$ZmfzEQj0" GlobalId="07C5C3$vz6oRj$ZmfzEQj0" Name="EnergyAbsportionCapacity7d" Description="Energy absorption capacity after 7 days according EN 14488-5 standard (only for fibre concrete)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcEnergyMeasure" />
				<IfcSimplePropertyTemplate id="EnergyConsumption_2FStwk6UX5ThoaIOB4preA" GlobalId="2FStwk6UX5ThoaIOB4preA" Name="EnergyConsumption" Description="Annual energy consumption requirement" TemplateType="p_singlevalue" PrimaryMeasureType="IfcEnergyMeasure" />
				<IfcSimplePropertyTemplate id="EnergyConversionEfficiency_0Q_KpfMv19ewQMdEiBbY7K" GlobalId="0Q_KpfMv19ewQMdEiBbY7K" Name="EnergyConversionEfficiency" Description="Measure of the efficiency of conversion of fuel energy to mechanical energy" TemplateType="p_singlevalue" PrimaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="EnergyEfficiencyRatio_3RsZA0qSWHuO00025QrE$V" GlobalId="3RsZA0qSWHuO00025QrE$V" Name="EnergyEfficiencyRatio" Description="Energy efficiency ratio (EER).

Ratio of net cooling capacity to the total input rate of electric power applied.  By definition, the units are BTU/hour per Watt.
The input electric power may be obtained from Pset_DistributionPortPHistoryElectrical.RealPower on the &apos;Power&apos; port of the IfcChiller." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="EnergyEfficiencyRatio_3T35y0qSeHuO00025QrE$V" GlobalId="3T35y0qSeHuO00025QrE$V" Name="EnergyEfficiencyRatio" Description="Energy efficiency ratio (EER)." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="EnergyGainSensible_0KA4E0qRuHuO00025QrE$V" GlobalId="0KA4E0qRuHuO00025QrE$V" Name="EnergyGainSensible" Description="The sum of total energy gains for the spaces served by the system during the peak cooling conditions, plus any system-level sensible energy gains." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="EnergyGainTotal_08rHW0qRuHuO00025QrE$V" GlobalId="08rHW0qRuHuO00025QrE$V" Name="EnergyGainTotal" Description="The total amount of energy gains for the spaces served by the system during the peak cooling conditions, plus any system-level total energy gains." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="EnergyLoss_0Qjhi0qRuHuO00025QrE$V" GlobalId="0Qjhi0qRuHuO00025QrE$V" Name="EnergyLoss" Description="The sum of energy losses for the spaces served by the system during the peak heating conditions." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="EnergySource_0XQn_0qWeHuO00025QrE$V" GlobalId="0XQn_0qWeHuO00025QrE$V" Name="EnergySource" Description="Enumeration defining the energy source or fuel cumbusted.

Note: hydronic heaters shall use UNSET; dual-use hydronic/electric heaters shall use ELECTRICITY." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" id="i990" Name="PEnum_EnergySource">
						<EnumerationValues>
							<IfcLabel-wrapper>COAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>COAL_PULVERIZED</IfcLabel-wrapper>
							<IfcLabel-wrapper>ELECTRICITY</IfcLabel-wrapper>
							<IfcLabel-wrapper>GAS</IfcLabel-wrapper>
							<IfcLabel-wrapper>OIL</IfcLabel-wrapper>
							<IfcLabel-wrapper>PROPANE</IfcLabel-wrapper>
							<IfcLabel-wrapper>WOOD</IfcLabel-wrapper>
							<IfcLabel-wrapper>WOOD_CHIP</IfcLabel-wrapper>
							<IfcLabel-wrapper>WOOD_PELLET</IfcLabel-wrapper>
							<IfcLabel-wrapper>WOOD_PULVERIZED</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="EnergySource_1Ve1a0qU4HuO00025QrE$V" GlobalId="1Ve1a0qU4HuO00025QrE$V" Name="EnergySource" Description="Enumeration defining the energy source or fuel cumbusted." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_EngineEnergySource">
						<EnumerationValues>
							<IfcLabel-wrapper>DIESEL</IfcLabel-wrapper>
							<IfcLabel-wrapper>GASOLINE</IfcLabel-wrapper>
							<IfcLabel-wrapper>NATURALGAS</IfcLabel-wrapper>
							<IfcLabel-wrapper>PROPANE</IfcLabel-wrapper>
							<IfcLabel-wrapper>BIODIESEL</IfcLabel-wrapper>
							<IfcLabel-wrapper>SEWAGEGAS</IfcLabel-wrapper>
							<IfcLabel-wrapper>HYDROGEN</IfcLabel-wrapper>
							<IfcLabel-wrapper>BIFUEL</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="EnergySource_2jyky0qSGHuO00025QrE$V" GlobalId="2jyky0qSGHuO00025QrE$V" Name="EnergySource" Description="Enumeration defining the energy source or fuel cumbusted." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i990" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="EnergySourceConsumption_13sae0qSGHuO00025QrE$V" GlobalId="13sae0qSGHuO00025QrE$V" Name="EnergySourceConsumption" Description="Energy consumption." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcEnergyMeasure" />
				<IfcSimplePropertyTemplate id="EnergySourceLabel_1mlnyMavn0XvUzU0A9esFc" GlobalId="1mlnyMavn0XvUzU0A9esFc" Name="EnergySourceLabel" Description="Type of energy source e.g. Electricity, Diesel, LPG etc. utilised by the element." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="EntranceLevel_22lC_0qSKHuO00025QrE$V" GlobalId="22lC_0qSKHuO00025QrE$V" Name="EntranceLevel" Description="Indication whether this building storey is an entrance level to the building (TRUE), or (FALSE) if otherwise." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="EquipmentCapacity_37sz88SXT3JOvbrpAb4kbe" GlobalId="37sz88SXT3JOvbrpAb4kbe" Name="EquipmentCapacity" Description="Indicates the equipment capacity of the appliance. The value is defined in bits/s." TemplateType="p_singlevalue" PrimaryMeasureType="IfcIntegerCountRateMeasure" />
				<IfcSimplePropertyTemplate id="EquipmentLoading_1e0Ns0$oTF1RHtc3O5zTbg" GlobalId="1e0Ns0$oTF1RHtc3O5zTbg" Name="EquipmentLoading" Description="Loading from equipment" TemplateType="p_singlevalue" PrimaryMeasureType="IfcForceMeasure" />
				<IfcSimplePropertyTemplate id="EquipmentSensible_20VMG0qWiHuO00025QrE$V" GlobalId="20VMG0qWiHuO00025QrE$V" Name="EquipmentSensible" Description="Heat gains and losses from equipment." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="EquipmentSensibleHistory_3zgDa0qWiHuO00025QrE$V" GlobalId="3zgDa0qWiHuO00025QrE$V" Name="EquipmentSensibleHistory" Description="Heat gains and losses from equipment." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="EscortRequirement_1TaeO0qV8HuO00025QrE$V" GlobalId="1TaeO0qV8HuO00025QrE$V" Name="EscortRequirement" Description="Indicates whether or not an escort is required to accompany persons carrying out a work order at or to/from the place of work (= TRUE) or not (= FALSE).

NOTE - There are many instances where escorting is required, particularly in a facility that has a high security rating. Escorting may require that persons are escorted to and from the place of work. Alternatively, it may involve the escort remaining at the place of work at all times." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="Eutrophication_1CsXG0qU8HuO00025QrE$V" GlobalId="1CsXG0qU8HuO00025QrE$V" Name="Eutrophication" Description="Quantity of eutrophicating compounds calculated in equivalent PO4." TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassMeasure" />
				<IfcSimplePropertyTemplate id="EutrophicationPerUnit_3tdWA0qU4HuO00025QrE$V" GlobalId="3tdWA0qU4HuO00025QrE$V" Name="EutrophicationPerUnit" Description="Quantity of eutrophicating compounds calculated in equivalent PO4" TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassMeasure" />
				<IfcSimplePropertyTemplate id="EvaporatingTemperature_3Rvom0qU8HuO00025QrE$V" GlobalId="3Rvom0qU8HuO00025QrE$V" Name="EvaporatingTemperature" Description="Refrigerant evaporating temperature." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="EvaporatorCoolant_0eomA0qUCHuO00025QrE$V" GlobalId="0eomA0qUCHuO00025QrE$V" Name="EvaporatorCoolant" Description="The fluid used for the coolant in the evaporator." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_EvaporatorCoolant">
						<EnumerationValues>
							<IfcLabel-wrapper>WATER</IfcLabel-wrapper>
							<IfcLabel-wrapper>BRINE</IfcLabel-wrapper>
							<IfcLabel-wrapper>GLYCOL</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="EvaporatorMeanVoidFraction_3uWsG0qU8HuO00025QrE$V" GlobalId="3uWsG0qU8HuO00025QrE$V" Name="EvaporatorMeanVoidFraction" Description="Mean void fraction in evaporator." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="EvaporatorMediumType_0RhXE0qUCHuO00025QrE$V" GlobalId="0RhXE0qUCHuO00025QrE$V" Name="EvaporatorMediumType" Description="ColdLiquid: Evaporator is using liquid type of fluid to exchange heat with refrigerant.
ColdAir: Evaporator is using air to exchange heat with refrigerant.
Property: RefrigerantClass description changed. New description:
Refrigerant class used by the object.
CFC: Chlorofluorocarbons.
HCFC: Hydrochlorofluorocarbons.
HFC: Hydrofluorocarbons." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_EvaporatorMediumType">
						<EnumerationValues>
							<IfcLabel-wrapper>COLDLIQUID</IfcLabel-wrapper>
							<IfcLabel-wrapper>COLDAIR</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ExcavationClass_0M$dI8P5T3I8$lTN_LlVyH" GlobalId="0M$dI8P5T3I8$lTN_LlVyH" Name="ExcavationClass" Description="Specifies an excavation class used in underground excavation." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ExcavationFaceInclination_0KcNnRVov7v8l33uxXOfnq" GlobalId="0KcNnRVov7v8l33uxXOfnq" Name="ExcavationFaceInclination" Description="Specifies the inclination of the tunnel face." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ExcavationFaceInclination">
						<EnumerationValues>
							<IfcLabel-wrapper>VERTICAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>INCLINED</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ExcavationFaceType_2a9lnvIGXBJf$bF3uy85d9" GlobalId="2a9lnvIGXBJf$bF3uy85d9" Name="ExcavationFaceType" Description="The excavation surface that was mapped." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ExcavationFaceType">
						<EnumerationValues>
							<IfcLabel-wrapper>TUNNELFACE</IfcLabel-wrapper>
							<IfcLabel-wrapper>TUNNELWALL</IfcLabel-wrapper>
							<IfcLabel-wrapper>TUNNELROOF</IfcLabel-wrapper>
							<IfcLabel-wrapper>INVERT</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ExcavationMethod_2LuXUw8cfApBjhWYFbeWrd" GlobalId="2LuXUw8cfApBjhWYFbeWrd" Name="ExcavationMethod" Description="Excavation method used." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ExcavationMethod">
						<EnumerationValues>
							<IfcLabel-wrapper>DRILLBLAST</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ExcavationStep_2DkWfNGnX34fa0JL31BjfI" GlobalId="2DkWfNGnX34fa0JL31BjfI" Name="ExcavationStep" Description="Excavation step." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ExcavationStep">
						<EnumerationValues>
							<IfcLabel-wrapper>TOPHEADING</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ExchangeCapacity_3BKPzAHt10s8UrVNVqgpxw" GlobalId="3BKPzAHt10s8UrVNVqgpxw" Name="ExchangeCapacity" Description="Indicates how many simultaneous calls the base transceiver station can handle." TemplateType="p_singlevalue" PrimaryMeasureType="IfcInteger" />
				<IfcSimplePropertyTemplate id="Exclusions_0my6M0qXOHuO00025QrE$V" GlobalId="0my6M0qXOHuO00025QrE$V" Name="Exclusions" Description="Items, conditions or actions that may be excluded from the warranty or that may cause the warranty to become void." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="ExhaustAir_2TiZA0qWiHuO00025QrE$V" GlobalId="2TiZA0qWiHuO00025QrE$V" Name="ExhaustAir" Description="Loads from exhaust air." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="ExhaustAirFlowRate_0nW$w0qWmHuO00025QrE$V" GlobalId="0nW$w0qWmHuO00025QrE$V" Name="ExhaustAirFlowRate" Description="Design exhaust air flow rate for the space." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="ExhaustAirFlowrate_1K_dc0qWiHuO00025QrE$V" GlobalId="1K_dc0qWiHuO00025QrE$V" Name="ExhaustAirFlowrate" Description="Design exhaust air flow rate for the space." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="ExhaustAirHistory_08$0I0qWmHuO00025QrE$V" GlobalId="08$0I0qWmHuO00025QrE$V" Name="ExhaustAirHistory" Description="Loads from exhaust air." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="ExpansionDirection_2DxkIX5iv4mB2_uToCgx$W" GlobalId="2DxkIX5iv4mB2_uToCgx$W" Name="ExpansionDirection" Description="The expansion direction, e.g. single direction, bi-direction" TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ExpansionDirection">
						<EnumerationValues>
							<IfcLabel-wrapper>SINGLE_DIRECTION</IfcLabel-wrapper>
							<IfcLabel-wrapper>BI_DIRECTION</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ExpectedServiceLife_2dlpk0qU4HuO00025QrE$V" GlobalId="2dlpk0qU4HuO00025QrE$V" Name="ExpectedServiceLife" Description="Expected service life in years." TemplateType="p_singlevalue" PrimaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="ExplosiveAtmosphereStandardsCompliance_35VZpD_jv1UwHKJjegrTFR" GlobalId="35VZpD_jv1UwHKJjegrTFR" Name="ExplosiveAtmosphereStandardsCompliance" Description="Information about compliance with regard to explosive atmosphere related standards." TemplateType="p_tablevalue" PrimaryMeasureType="IfcLabel" SecondaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="ExposureClass_2RxWltAjDAPhxrUt6toXTR" GlobalId="2RxWltAjDAPhxrUt6toXTR" Name="ExposureClass" Description="Classification of exposure to environmental conditions, usually specified in accordance with the concrete design code which is applied in the project." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ExtendToStructure_3g0d00qXKHuO00025QrE$V" GlobalId="3g0d00qXKHuO00025QrE$V" Name="ExtendToStructure" Description="Indicates whether the object extend to the structure above (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="ExteriorHeatTransferCoefficient_1a3WS0qSmHuO00025QrE$V" GlobalId="1a3WS0qSmHuO00025QrE$V" Name="ExteriorHeatTransferCoefficient" Description="Exterior heat transfer coefficient associated with exterior surface area." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcThermalTransmittanceMeasure" />
				<IfcSimplePropertyTemplate id="ExteriorHeatTransferCoefficient_3HB9S0qU8HuO00025QrE$V" GlobalId="3HB9S0qU8HuO00025QrE$V" Name="ExteriorHeatTransferCoefficient" Description="Exterior heat transfer coefficient associated with exterior surface area." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcThermalTransmittanceMeasure" />
				<IfcSimplePropertyTemplate id="ExternalAdjusted_1H4Yk0qVeHuO00025QrE$V" GlobalId="1H4Yk0qVeHuO00025QrE$V" Name="ExternalAdjusted" Description="An indication if the ground fault protection may be adjusted according to an external current coil or not." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="ExternalSurfaceArea_1G8S_0qUCHuO00025QrE$V" GlobalId="1G8S_0qUCHuO00025QrE$V" Name="ExternalSurfaceArea" Description="External surface area (both primary and secondary area)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAreaMeasure" />
				<IfcSimplePropertyTemplate id="ExternalSurfaceArea_2myTs0qSmHuO00025QrE$V" GlobalId="2myTs0qSmHuO00025QrE$V" Name="ExternalSurfaceArea" Description="External surface area (both primary and secondary area)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAreaMeasure" />
				<IfcSimplePropertyTemplate id="ExtremeHighWaterLevel_3GFn0Pp5r0eQGPHYahYbQS" GlobalId="3GFn0Pp5r0eQGPHYahYbQS" Name="ExtremeHighWaterLevel" Description="Extreme high water level" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="ExtremeLowWaterLevel_2BQGedM913bgYQyPz49FRV" GlobalId="2BQGedM913bgYQyPz49FRV" Name="ExtremeLowWaterLevel" Description="Extreme low water level" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="FaceArea_12Oqw0qT4HuO00025QrE$V" GlobalId="12Oqw0qT4HuO00025QrE$V" Name="FaceArea" Description="Face area open to the airstream." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAreaMeasure" />
				<IfcSimplePropertyTemplate id="FaceExcavationType_2bpyAfLPD1KPvgab$9KTzT" GlobalId="2bpyAfLPD1KPvgab$9KTzT" Name="FaceExcavationType" Description="Face excavation type." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_FaceExcavationType">
						<EnumerationValues>
							<IfcLabel-wrapper>FULLFACE</IfcLabel-wrapper>
							<IfcLabel-wrapper>STAGED</IfcLabel-wrapper>
							<IfcLabel-wrapper>PILOTBORE</IfcLabel-wrapper>
							<IfcLabel-wrapper>SHAFT</IfcLabel-wrapper>
							<IfcLabel-wrapper>CROSSCONNECTION</IfcLabel-wrapper>
							<IfcLabel-wrapper>REAMING</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="FaceSurfaceArea_1vGr_0qUKHuO00025QrE$V" GlobalId="1vGr_0qUKHuO00025QrE$V" Name="FaceSurfaceArea" Description="Face area of filter frame." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAreaMeasure" />
				<IfcSimplePropertyTemplate id="FaceType_1xaiC0qRyHuO00025QrE$V" GlobalId="1xaiC0qRyHuO00025QrE$V" Name="FaceType" Description="Identifies how the terminal face of an AirTerminal is constructed." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_AirTerminalFaceType">
						<EnumerationValues>
							<IfcLabel-wrapper>FOURWAYPATTERN</IfcLabel-wrapper>
							<IfcLabel-wrapper>SINGLEDEFLECTION</IfcLabel-wrapper>
							<IfcLabel-wrapper>DOUBLEDEFLECTION</IfcLabel-wrapper>
							<IfcLabel-wrapper>SIGHTPROOF</IfcLabel-wrapper>
							<IfcLabel-wrapper>EGGCRATE</IfcLabel-wrapper>
							<IfcLabel-wrapper>PERFORATED</IfcLabel-wrapper>
							<IfcLabel-wrapper>LOUVERED</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="FaceVelocity_2E4Ve0qSaHuO00025QrE$V" GlobalId="2E4Ve0qSaHuO00025QrE$V" Name="FaceVelocity" Description="Air velocity through the coil." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcLinearVelocityMeasure" />
				<IfcSimplePropertyTemplate id="FaciesLithostratigraphy_2XLky_iMD0vQgzsjnsjpw7" GlobalId="2XLky_iMD0vQgzsjnsjpw7" Name="FaciesLithostratigraphy" Description="The characteristics of a rock or a sediment unit that reflect its environment of deposition and allow it to be distinguished from rock or sediment deposited in an adjacent environment." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="FaciesPetrophysics_2Jx2bqqWv50AEBqzbKQZTD" GlobalId="2Jx2bqqWv50AEBqzbKQZTD" Name="FaciesPetrophysics" Description="A rock mass that can be recognized by its composition, structures or fossil content and mapped on the basis of those characteristics." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="FacsimileNumbers_1LEVuixsX5lBZLGyTmhuSA" GlobalId="1LEVuixsX5lBZLGyTmhuSA" Name="FacsimileNumbers" Description="The list of fax numbers at which fax messages may be received." TemplateType="p_listvalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="FailPosition_12MLE0qRqHuO00025QrE$V" GlobalId="12MLE0qRqHuO00025QrE$V" Name="FailPosition" Description="Specifies the required fail-safe position of the actuator." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_FailPosition">
						<EnumerationValues>
							<IfcLabel-wrapper>FAILOPEN</IfcLabel-wrapper>
							<IfcLabel-wrapper>FAILCLOSED</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="FailureInformation_30Y_YD1x1DY8_4MwqYT1kM" GlobalId="30Y_YD1x1DY8_4MwqYT1kM" Name="FailureInformation" Description="The information for failure description." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="FairleadToTermination_0aBTPQFeHAF9vXo$IOf74h" GlobalId="0aBTPQFeHAF9vXo$IOf74h" Name="FairleadToTermination" Description="Distance from the fairlead to the bitt or winch on the vessel where the line terminates" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="Fan_0N0LE0qXCHuO00025QrE$V" GlobalId="0N0LE0qXCHuO00025QrE$V" Name="Fan" Description="Indicates fan operation where True is on, False is off, and Unknown is automatic." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcLogical" />
				<IfcSimplePropertyTemplate id="FanArrangement_2YOl20qUCHuO00025QrE$V" GlobalId="2YOl20qUCHuO00025QrE$V" Name="FanArrangement" Description="Defines the fan and motor drive arrangement as defined by AMCA.

ARRANGEMENT1: Arrangement 1.
ARRANGEMENT2: Arrangement 2.
ARRANGEMENT3: Arrangement 3.
ARRANGEMENT4: Arrangement 4.
ARRANGEMENT7: Arrangement 7.
ARRANGEMENT8: Arrangement 8.
ARRANGEMENT9: Arrangement 9.
ARRANGEMENT10: Arrangement 10.
OTHER: Other type of fan drive arrangement." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_CentrifugalFanArrangement">
						<EnumerationValues>
							<IfcLabel-wrapper>ARRANGEMENT1</IfcLabel-wrapper>
							<IfcLabel-wrapper>ARRANGEMENT2</IfcLabel-wrapper>
							<IfcLabel-wrapper>ARRANGEMENT3</IfcLabel-wrapper>
							<IfcLabel-wrapper>ARRANGEMENT4</IfcLabel-wrapper>
							<IfcLabel-wrapper>ARRANGEMENT7</IfcLabel-wrapper>
							<IfcLabel-wrapper>ARRANGEMENT8</IfcLabel-wrapper>
							<IfcLabel-wrapper>ARRANGEMENT9</IfcLabel-wrapper>
							<IfcLabel-wrapper>ARRANGEMENT10</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="FanEfficiency_0cjNE0qUGHuO00025QrE$V" GlobalId="0cjNE0qUGHuO00025QrE$V" Name="FanEfficiency" Description="Fan mechanical efficiency." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="FanMountingType_3w0Lm0qUCHuO00025QrE$V" GlobalId="3w0Lm0qUCHuO00025QrE$V" Name="FanMountingType" Description="Defines the method of mounting the fan in the building." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_FanMountingType">
						<EnumerationValues>
							<IfcLabel-wrapper>MANUFACTUREDCURB</IfcLabel-wrapper>
							<IfcLabel-wrapper>FIELDERECTEDCURB</IfcLabel-wrapper>
							<IfcLabel-wrapper>CONCRETEPAD</IfcLabel-wrapper>
							<IfcLabel-wrapper>SUSPENDED</IfcLabel-wrapper>
							<IfcLabel-wrapper>WALLMOUNTED</IfcLabel-wrapper>
							<IfcLabel-wrapper>DUCTMOUNTED</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="FanPower_1Fmms0qRuHuO00025QrE$V" GlobalId="1Fmms0qRuHuO00025QrE$V" Name="FanPower" Description="Fan motor loads contributing to the cooling load." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="FanPowerRate_0igrI0qUGHuO00025QrE$V" GlobalId="0igrI0qUGHuO00025QrE$V" Name="FanPowerRate" Description="Fan power consumption." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="FanRotationSpeed_0W9lm0qUGHuO00025QrE$V" GlobalId="0W9lm0qUGHuO00025QrE$V" Name="FanRotationSpeed" Description="Fan rotation speed." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcRotationalFrequencyMeasure" />
				<IfcSimplePropertyTemplate id="FasteningType_1BGxpp0rr4tv$oIacUcEQG" GlobalId="1BGxpp0rr4tv$oIacUcEQG" Name="FasteningType" Description="Indicates the type of fastening used to generate traction between the foot of the rail and the sleeper. It depends on but is not uniquely identified by the type of sleeper. This property shall only be used when sleeper fastening is not modelled as an element." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="FaucetFunction_3Bw400qXGHuO00025QrE$V" GlobalId="3Bw400qXGHuO00025QrE$V" Name="FaucetFunction" Description="Defines the operating temperature of a faucet that may be specified." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_FaucetFunction">
						<EnumerationValues>
							<IfcLabel-wrapper>COLD</IfcLabel-wrapper>
							<IfcLabel-wrapper>HOT</IfcLabel-wrapper>
							<IfcLabel-wrapper>MIXED</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="FaucetOperation_2t2wo0qXGHuO00025QrE$V" GlobalId="2t2wo0qXGHuO00025QrE$V" Name="FaucetOperation" Description="Defines the range of ways in which a faucet can be operated that may be specified where:

CeramicDisc: Quick action faucet with a ceramic seal to open or close the orifice
.
LeverHandle: Quick action faucet that is operated by a lever handle
.
NonConcussiveSelfClosing:    Self closing faucet that does not induce surge pressure
.
QuarterTurn: Quick action faucet that can be fully opened or shut by turning the operating mechanism through 90 degrees.
QuickAction: Faucet that can be opened or closed fully with a single small movement of the operating mechanism
.
ScrewDown: Faucet in which a plate or disc is moved, by the rotation of a screwed spindle, to close or open the orifice.
SelfClosing: Faucet that is opened by pressure of the top of an operating spindle and is closed under the action of a spring or weight when the pressure is released.
TimedSelfClosing:   Self closing faucet that discharges for a predetermined period of time
." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_FaucetOperation">
						<EnumerationValues>
							<IfcLabel-wrapper>CERAMICDISC</IfcLabel-wrapper>
							<IfcLabel-wrapper>LEVERHANDLE</IfcLabel-wrapper>
							<IfcLabel-wrapper>NONCONCUSSIVESELFCLOSING</IfcLabel-wrapper>
							<IfcLabel-wrapper>QUARTERTURN</IfcLabel-wrapper>
							<IfcLabel-wrapper>QUICKACTION</IfcLabel-wrapper>
							<IfcLabel-wrapper>SCREWDOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>SELFCLOSING</IfcLabel-wrapper>
							<IfcLabel-wrapper>TIMEDSELFCLOSING</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="FaucetTopDescription_3WB3q0qXGHuO00025QrE$V" GlobalId="3WB3q0qXGHuO00025QrE$V" Name="FaucetTopDescription" Description="Description of the operating mechanism/top of the faucet." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="FaucetType_2Z_Do0qXGHuO00025QrE$V" GlobalId="2Z_Do0qXGHuO00025QrE$V" Name="FaucetType" Description="Defines the range of faucet types that may be specified where:

Bib:     Faucet with a horizontal inlet and a nozzle that discharges downwards.
Globe:   Faucet fitted through the end of a bath, with a horizontal inlet, a partially spherical body and a vertical nozzle.
Diverter:   Combination faucet assembly with a valve to enable the flow of mixed water to be transferred to a showerhead.
DividedFlowCombination:  Combination faucet assembly in which hot and cold water are kept separate until emerging from a common nozzle
.
Pillar:  Faucet that has a vertical inlet and a nozzle that discharges downwards
.
SingleOutletCombination =    Combination faucet assembly in which hot and cold water mix before emerging from a common nozzle
.
Spray:   Faucet with a spray outlet
.
SprayMixing:     Spray faucet connected to hot and cold water supplies that delivers water at a temperature determined during use." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_FaucetType">
						<EnumerationValues>
							<IfcLabel-wrapper>BIB</IfcLabel-wrapper>
							<IfcLabel-wrapper>GLOBE</IfcLabel-wrapper>
							<IfcLabel-wrapper>DIVERTER</IfcLabel-wrapper>
							<IfcLabel-wrapper>DIVIDEDFLOWCOMBINATION</IfcLabel-wrapper>
							<IfcLabel-wrapper>PILLAR</IfcLabel-wrapper>
							<IfcLabel-wrapper>SINGLEOUTLETCOMBINATION</IfcLabel-wrapper>
							<IfcLabel-wrapper>SPRAY</IfcLabel-wrapper>
							<IfcLabel-wrapper>SPRAYMIXING</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="FaultActivity_2JUec9o7r0AvVBR7Pu457g" GlobalId="2JUec9o7r0AvVBR7Pu457g" Name="FaultActivity" Description="Qualitative rating of the fault activitity (active/inactive/...). E.g. an acttive fault is a fault that has slipped in historic time and which is likely to slip again in the future." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="FaultDeformationStyle_1lYGGx_1jCCxEUZce$aPdE" GlobalId="1lYGGx_1jCCxEUZce$aPdE" Name="FaultDeformationStyle" Description="A human readable description of the style of deformation (e.g. brittle, ductile etc.) for the object. To report an identifier from a controlled vocabulary, deformationStyle_uri shall be used.

&gt; NOTE: Definition according to OGC Geoscience Markup Language 4.1 (GeoSciML) (8.9.8.7 deformationStyle) 
&gt; NOTE: A controlled vocabulary may be found at  http://resource.geosciml.org/classifier/cgi/deformationstyle" TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="FaultDisplacement_1SqeJ7wlr3KhX7hE0uIsj3" GlobalId="1SqeJ7wlr3KhX7hE0uIsj3" Name="FaultDisplacement" Description="Human readable summary describing the displacement across the object.

&gt; NOTE: Definition according to OGC Geoscience Markup Language 4.1 (GeoSciML) (8.9.8.8 displacement)" TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="FaultGeologicHistory_2VqusjTyz7Rwv4WEaW6XDu" GlobalId="2VqusjTyz7Rwv4WEaW6XDu" Name="FaultGeologicHistory" Description="Description of the age of the object, possibly formatted with formal syntax, (where age is a sequence of events and may include process and environment information).

&gt; NOTE: Definition according to OGC Geoscience Markup Language 4.1 (GeoSciML) (8.9.8.9 geologicHistory)" TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="FaultInfilling_2JZfahd4z6yxCGa85SabRQ" GlobalId="2JZfahd4z6yxCGa85SabRQ" Name="FaultInfilling" Description="Substance dispersed between the wall surfaces of a discontinuity (JGS) generally, the material occupying the space between joint surfaces, faults, and other rock discontinuities. The filling material may be clay, gouge, various natural cementing agents, or alteration products of the adjacent rock." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="FaultLength_36HCJE4Fj1vAsieqy08nef" GlobalId="36HCJE4Fj1vAsieqy08nef" Name="FaultLength" Description="Length range of the exposed fault trace." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="FaultLength_3afQABxmjCF9PigO8LJ2xb" GlobalId="3afQABxmjCF9PigO8LJ2xb" Name="FaultLength" Description="Fault length (L) is the longest horizontal or subhorizontal dimension along the fault plane." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="FaultMovementType_1HEf8LNPb5ZAU_EKoyIhJa" GlobalId="1HEf8LNPb5ZAU_EKoyIhJa" Name="FaultMovementType" Description="Contains a human readable summary of the type of movement (e.g. dip-slip, strike-slip) on the object. To report an identifier from a controlled vocabulary, movementType_uri shall be used.

&gt; NOTE: Definition according to OGC Geoscience Markup Language 4.1 (GeoSciML) (8.9.8.6 movementType) 

&gt; NOTE: A controlled vocabulary may be found at  http://resource.geosciml.org/classifier/cgi/faultmovementtype" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="FaultPitchAngle_2amUo6QL91DeGgZLQHgMyf" GlobalId="2amUo6QL91DeGgZLQHgMyf" Name="FaultPitchAngle" Description="Angle between the strike of the slip surface and the slip vector (striation).

&gt; NOTE&amp;nbsp; In geology, &quot;pitch&quot; and &quot;rake&quot; are terms used to describe the orientation and inclination of geological features, such as folds and faults, with respect to a horizontal plane. Pitch refers to the angle of inclination of a geological feature from the horizontal plane, measured perpendicular to the strike of the feature. It is commonly expressed in degrees or as a ratio of vertical to horizontal distance. For example, if a geological feature has a pitch of 45 degrees, it means that it is inclined at an angle of 45 degrees from the horizontal. Rake, on the other hand, refers to the angle of inclination of a geological feature measured parallel to the strike of the feature. It is also commonly expressed in degrees or as a ratio of vertical to horizontal distance. Rake is often used to describe the orientation of faults, where it represents the angle between the fault plane and a horizontal plane. Both pitch and rake are important parameters in geology as they can provide information about the deformation history and the mechanical behavior of rocks in response to tectonic forces." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="FaultPriorityType_2JXZa0qVSHuO00025QrE$V" GlobalId="2JXZa0qVSHuO00025QrE$V" Name="FaultPriorityType" Description="Identifies the predefined types of priority that can be assigned from which the type may be set where:

High: action is required urgently.
Medium: action can occur within a reasonable period of time.
Low: action can occur when convenient." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" id="i1079" Name="PEnum_PriorityType">
						<EnumerationValues>
							<IfcLabel-wrapper>HIGH</IfcLabel-wrapper>
							<IfcLabel-wrapper>MEDIUM</IfcLabel-wrapper>
							<IfcLabel-wrapper>LOW</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="FaultSlipDirection_0_Rv9JVL5DTR1ugllbwXU4" GlobalId="0_Rv9JVL5DTR1ugllbwXU4" Name="FaultSlipDirection" Description="Observed relative displacement direction of the hanging wall (top) to the footwall, e.g. up. down, left, right or combinations (like top down - left) when looking from one block across the fault to the other block.

![FaultSlipDirection](..\..\..\figures\FaultSlipDirection.png  &quot;Figure 1&quot;)" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="FaultSlipDirection_1Bo9zfmPXBcf$1nNl3sOVz" GlobalId="1Bo9zfmPXBcf$1nNl3sOVz" Name="FaultSlipDirection" Description="Observed relative displacement direction of the hanging wall (top) to the foot wall, e.g. up, down, left, right or combinations (like top down - left)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="FaultThickness_3pHrpKqNzD2x2$n3ipmRil" GlobalId="3pHrpKqNzD2x2$n3ipmRil" Name="FaultThickness" Description="Thickness range of the fault zone, which can range from millimeters to kilometers." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcNonNegativeLengthMeasure" />
				<IfcSimplePropertyTemplate id="FaultType_2cTF3eVlf2_80LnK_n7O6x" GlobalId="2cTF3eVlf2_80LnK_n7O6x" Name="FaultType" Description="Type of the fault classified with the dip and the direction of slip." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="FenderType_3saZ7owb5D$BDYSbnCWq1T" GlobalId="3saZ7owb5D$BDYSbnCWq1T" Name="FenderType" Description="The type of fender" TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_FenderType">
						<EnumerationValues>
							<IfcLabel-wrapper>ARCH</IfcLabel-wrapper>
							<IfcLabel-wrapper>CELL</IfcLabel-wrapper>
							<IfcLabel-wrapper>CONE</IfcLabel-wrapper>
							<IfcLabel-wrapper>CYLINDER</IfcLabel-wrapper>
							<IfcLabel-wrapper>PNEUMATIC</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="FiberColour_1HeG7B2WPEjBPpFB1rwWJ_" GlobalId="1HeG7B2WPEjBPpFB1rwWJ_" Name="FiberColour" Description="Indicates the colour of a single fiber." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" id="i1087" Name="PEnum_FiberColour">
						<EnumerationValues>
							<IfcLabel-wrapper>AQUA</IfcLabel-wrapper>
							<IfcLabel-wrapper>BLACK</IfcLabel-wrapper>
							<IfcLabel-wrapper>BLUE</IfcLabel-wrapper>
							<IfcLabel-wrapper>BROWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>GREEN</IfcLabel-wrapper>
							<IfcLabel-wrapper>ORANGE</IfcLabel-wrapper>
							<IfcLabel-wrapper>RED</IfcLabel-wrapper>
							<IfcLabel-wrapper>ROSE</IfcLabel-wrapper>
							<IfcLabel-wrapper>SLATE</IfcLabel-wrapper>
							<IfcLabel-wrapper>VIOLET</IfcLabel-wrapper>
							<IfcLabel-wrapper>WHITE</IfcLabel-wrapper>
							<IfcLabel-wrapper>YELLOW</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="FiberMode_0_QAybmkz5UQ9pCD5EbZDf" GlobalId="0_QAybmkz5UQ9pCD5EbZDf" Name="FiberMode" Description="Indicates the fiber mode." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_FiberMode">
						<EnumerationValues>
							<IfcLabel-wrapper>MULTIMODE</IfcLabel-wrapper>
							<IfcLabel-wrapper>SINGLEMODE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="FiberTubeColour_3m0FdinCDDhAUaT$zdvYyG" GlobalId="3m0FdinCDDhAUaT$zdvYyG" Name="FiberTubeColour" Description="Indicates the colour of a single fiber tube." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i1087" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="FiberType_33hW6SI9L88u4r9StkBaiz" GlobalId="33hW6SI9L88u4r9StkBaiz" Name="FiberType" Description="Indicates the type of the single fiber." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_FiberType">
						<EnumerationValues>
							<IfcLabel-wrapper>STANDARDSINGLEMODEFIBER</IfcLabel-wrapper>
							<IfcLabel-wrapper>LOWWATERPEAKFIBER</IfcLabel-wrapper>
							<IfcLabel-wrapper>DISPERSIONSHIFTEDFIBER</IfcLabel-wrapper>
							<IfcLabel-wrapper>CUTOFFSHIFTEDFIBER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NON_ZERODISPERSIONSHIFTEDFIBER</IfcLabel-wrapper>
							<IfcLabel-wrapper>BEND_INSENSITIVEFIBER</IfcLabel-wrapper>
							<IfcLabel-wrapper>OM1</IfcLabel-wrapper>
							<IfcLabel-wrapper>OM2</IfcLabel-wrapper>
							<IfcLabel-wrapper>OM3</IfcLabel-wrapper>
							<IfcLabel-wrapper>OM4</IfcLabel-wrapper>
							<IfcLabel-wrapper>OM5</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="FibreDiameter_2AiOsSAiPEYh8W2tTL3V$g" GlobalId="2AiOsSAiPEYh8W2tTL3V$g" Name="FibreDiameter" Description="Diameter of the fibre." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="FibreLength_2UeiJ9HTnA0RPlmDtOHWGq" GlobalId="2UeiJ9HTnA0RPlmDtOHWGq" Name="FibreLength" Description="Length of the fibre." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="FibreType_0ZIZhcg8bFQgae_dc42mCB" GlobalId="0ZIZhcg8bFQgae_dc42mCB" Name="FibreType" Description="The type of fibre used to reinforce the sprayed concrete." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_SprayedConcreteFibreType">
						<EnumerationValues>
							<IfcLabel-wrapper>STEEL</IfcLabel-wrapper>
							<IfcLabel-wrapper>MACRO_POLYPROPYLEN</IfcLabel-wrapper>
							<IfcLabel-wrapper>MICRO_POLYPROPYLEN</IfcLabel-wrapper>
							<IfcLabel-wrapper>GLASSFIBRE</IfcLabel-wrapper>
							<IfcLabel-wrapper>USERDEFINED</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="FibreVolumeRatio_1lDCr_KiHEZxCLwJ6YMCr2" GlobalId="1lDCr_KiHEZxCLwJ6YMCr2" Name="FibreVolumeRatio" Description="Quantity of fibres per cubic meter of shotcrete." TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassDensityMeasure" />
				<IfcSimplePropertyTemplate id="FillGas_0zf9U0qTqHuO00025QrE$V" GlobalId="0zf9U0qTqHuO00025QrE$V" Name="FillGas" Description="Name of the gas by which the gap between two glass layers is filled. It is given for information purposes only." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="FillingDepth_0d1eKod4HE_90bPLI3qHu4" GlobalId="0d1eKod4HE_90bPLI3qHu4" Name="FillingDepth" Description="Depth of filling (boreholeML)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="FillingMaterial_3uWSi7iqf6HQyEUUpQ5uip" GlobalId="3uWSi7iqf6HQyEUUpQ5uip" Name="FillingMaterial" Description="Filling material or &apos;NOT FILLED&apos; or &apos;UNKNOWN&apos; (boreholeML)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="FillVolume_01qLQPtGjD18MWw5eA$xzs" GlobalId="01qLQPtGjD18MWw5eA$xzs" Name="FillVolume" Description="Relative volume of fill (controlled placement of anthropogenic soil) stratum constituents." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumeMeasure" />
				<IfcSimplePropertyTemplate id="FinalResistance_3O2Da0qUKHuO00025QrE$V" GlobalId="3O2Da0qUKHuO00025QrE$V" Name="FinalResistance" Description="Filter fluid resistance when replacement is required (i.e., Pressure drop at the maximum air flowrate across the filter when the filter needs replacement per ASHRAE Standard 52.1)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="FinCorrugatedType_3yBjy0qX8HuO00025QrE$V" GlobalId="3yBjy0qX8HuO00025QrE$V" Name="FinCorrugatedType" Description="Description of a fin corrugated type." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="Finish_1MMe20qT0HuO00025QrE$V" GlobalId="1MMe20qT0HuO00025QrE$V" Name="Finish" Description="Description of the (surface) finish of the object for informational purposes." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="Finish_3QDbm0qXGHuO00025QrE$V" GlobalId="3QDbm0qXGHuO00025QrE$V" Name="Finish" Description="Description of the (surface) finish of the object for informational purposes." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="FinishColour_0qhCc0qSyHuO00025QrE$V" GlobalId="0qhCc0qSyHuO00025QrE$V" Name="FinishColour" Description="The finish colour of the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="FinishColour_3mPVq0qRyHuO00025QrE$V" GlobalId="3mPVq0qRyHuO00025QrE$V" Name="FinishColour" Description="The finish colour of the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="Finishing_0rPL00qWyHuO00025QrE$V" GlobalId="0rPL00qWyHuO00025QrE$V" Name="Finishing" Description="The finishing applied to system furniture elements of this type e.g. walnut, fabric." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="FinishType_3ZIGu0qRyHuO00025QrE$V" GlobalId="3ZIGu0qRyHuO00025QrE$V" Name="FinishType" Description="The type of finish for the air terminal." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_AirTerminalFinishType">
						<EnumerationValues>
							<IfcLabel-wrapper>ANNODIZED</IfcLabel-wrapper>
							<IfcLabel-wrapper>PAINTED</IfcLabel-wrapper>
							<IfcLabel-wrapper>NONE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="FireExit_00NVi0qXaHuO00025QrE$V" GlobalId="00NVi0qXaHuO00025QrE$V" Name="FireExit" Description="Indication whether this object is designed to serve as an exit in the case of fire (TRUE) or not (FALSE).

Here it defines an exit window in accordance to the national building code." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="FireExit_0Caee0qX8HuO00025QrE$V" GlobalId="0Caee0qX8HuO00025QrE$V" Name="FireExit" Description="Indication whether this object is designed to serve as an exit in the case of fire (TRUE) or not (FALSE).
Here whether the transport element (in case of e.g., a lift) is designed to serve as a fire exit, e.g., for fire escape purposes." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="FireExit_0YKO20qWqHuO00025QrE$V" GlobalId="0YKO20qWqHuO00025QrE$V" Name="FireExit" Description="Indication whether this object is designed to serve as an exit in the case of fire (TRUE) or not (FALSE).

Here it defines an exit stair in accordance to the national building code." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="FireExit_1RWlG0qVyHuO00025QrE$V" GlobalId="1RWlG0qVyHuO00025QrE$V" Name="FireExit" Description="Indication whether this object is designed to serve as an exit in the case of fire (TRUE) or not (FALSE).

Here it defines an exit ramp in accordance to the national building code." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="FireExit_1sylo0qWaHuO00025QrE$V" GlobalId="1sylo0qWaHuO00025QrE$V" Name="FireExit" Description="Indication whether this object is designed to serve as an exit in the case of fire (TRUE) or not (FALSE).

Here whether the space (in case of e.g., a corridor) is designed to serve as an exit space, e.g., for fire escape purposes." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="FireExit_2FcEs0qTmHuO00025QrE$V" GlobalId="2FcEs0qTmHuO00025QrE$V" Name="FireExit" Description="Indication whether this object is designed to serve as an exit in the case of fire (TRUE) or not (FALSE).

Here it defines an exit door in accordance to the national building code." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="FireExit_30p_Y0qV4HuO00025QrE$V" GlobalId="30p_Y0qV4HuO00025QrE$V" Name="FireExit" Description="Indication whether this object is designed to serve as an exit in the case of fire (TRUE) or not (FALSE).

Here whether the space (in case of e.g., a corridor) is designed to serve as an exit space, e.g., for fire escape purposes." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="FireFightingLift_0QI0_0qX8HuO00025QrE$V" GlobalId="0QI0_0qX8HuO00025QrE$V" Name="FireFightingLift" Description="Indication whether the elevator is designed to serve as a fire fighting lift the case of fire (TRUE) or not (FALSE). A fire fighting lift is used by fire fighters to access the location of fire and to evacuate people." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="FireHydrantType_2AGA20qUOHuO00025QrE$V" GlobalId="2AGA20qUOHuO00025QrE$V" Name="FireHydrantType" Description="Defines the range of hydrant types from which the required type can be selected where.
DryBarrel:   A hydrant that has isolating valves fitted below ground and that may be used where the possibility of water freezing is a consideration.
WetBarrel:   A hydrant that has isolating valves fitted above ground and that may be used where there is no possibility of water freezing." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_FireHydrantType">
						<EnumerationValues>
							<IfcLabel-wrapper>DRYBARREL</IfcLabel-wrapper>
							<IfcLabel-wrapper>WETBARREL</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="FireProofingStandardsCompliance_1iAbIgVqX9OPjRqWkzGyLL" GlobalId="1iAbIgVqX9OPjRqWkzGyLL" Name="FireProofingStandardsCompliance" Description="Information about compliance with regard to fire proofing related standards." TemplateType="p_tablevalue" PrimaryMeasureType="IfcLabel" SecondaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="FireProtectionClass_03Bm20qSKHuO00025QrE$V" GlobalId="03Bm20qSKHuO00025QrE$V" Name="FireProtectionClass" Description="Main fire protection class for the building which is assigned from the fire protection classification table as given by the relevant national building code." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="FireRating_0eTJm0qT0HuO00025QrE$V" GlobalId="0eTJm0qT0HuO00025QrE$V" Name="FireRating" Description="Fire rating for this object. It is given according to the national fire safety classification." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="FireRating_0i6he0qVGHuO00025QrE$V" GlobalId="0i6he0qVGHuO00025QrE$V" Name="FireRating" Description="Fire rating for this object. It is given according to the national fire safety classification." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="FireRating_0Jj9g0qWWHuO00025QrE$V" GlobalId="0Jj9g0qWWHuO00025QrE$V" Name="FireRating" Description="Fire rating for this object. It is given according to the national fire safety classification." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="FireRating_0P_KM0qWqHuO00025QrE$V" GlobalId="0P_KM0qWqHuO00025QrE$V" Name="FireRating" Description="Fire rating for this object. It is given according to the national fire safety classification." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="FireRating_0uXnw0qSGHuO00025QrE$V" GlobalId="0uXnw0qSGHuO00025QrE$V" Name="FireRating" Description="Fire rating for this object. It is given according to the national fire safety classification." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="FireRating_1_Wi5CzOTB$eL7qP2aEEGc" GlobalId="1_Wi5CzOTB$eL7qP2aEEGc" Name="FireRating" Description="Fire rating for the element. It is given according to the national fire safety classification." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="FireRating_1iiGu0qSaHuO00025QrE$V" GlobalId="1iiGu0qSaHuO00025QrE$V" Name="FireRating" Description="Fire rating for this object. It is given according to the national fire safety classification." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="FireRating_1LZHC0qVyHuO00025QrE$V" GlobalId="1LZHC0qVyHuO00025QrE$V" Name="FireRating" Description="Fire rating for this object. It is given according to the national fire safety classification." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="FireRating_1m6F5jtsz3BApAikzRRd5J" GlobalId="1m6F5jtsz3BApAikzRRd5J" Name="FireRating" Description="Fire rating for this object. It is given according to the national fire safety classification.

Requirement for the element filling the opening." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="FireRating_2$$dq0qXWHuO00025QrE$V" GlobalId="2$$dq0qXWHuO00025QrE$V" Name="FireRating" Description="Fire rating for this object. It is given according to the national fire safety classification." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="FireRating_20S6g0qV4HuO00025QrE$V" GlobalId="20S6g0qV4HuO00025QrE$V" Name="FireRating" Description="Fire rating for this object. It is given according to the national fire safety classification." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="FireRating_2rXBa0qW4HuO00025QrE$V" GlobalId="2rXBa0qW4HuO00025QrE$V" Name="FireRating" Description="Fire rating for this object. It is given according to the national fire safety classification." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="FireRating_39EXg0qXKHuO00025QrE$V" GlobalId="39EXg0qXKHuO00025QrE$V" Name="FireRating" Description="Fire rating for this object. It is given according to the national fire safety classification." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="FireResistanceRating_075K_0qT8HuO00025QrE$V" GlobalId="075K_0qT8HuO00025QrE$V" Name="FireResistanceRating" Description="Measure of the fire resistance rating in hours (e.g., 1.5 hours, 2 hours, etc.)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="FireResistanceRating_3MDHg0qT4HuO00025QrE$V" GlobalId="3MDHg0qT4HuO00025QrE$V" Name="FireResistanceRating" Description="Measure of the fire resistance rating in hours (e.g., 1.5 hours, 2 hours, etc.)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="FireRiskFactor_0pc8u0qWaHuO00025QrE$V" GlobalId="0pc8u0qWaHuO00025QrE$V" Name="FireRiskFactor" Description="Fire Risk factor assigned to the space according to local building regulations. It defines the fire risk of the space at several levels of fire hazard." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="FireSensorSetPoint_0WWxy0qWKHuO00025QrE$V" GlobalId="0WWxy0qWKHuO00025QrE$V" Name="FireSensorSetPoint" Description="The temperature value to be sensed to indicate the presence of fire." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="FirmwareVersion_2hICU0qSqHuO00025QrE$V" GlobalId="2hICU0qSqHuO00025QrE$V" Name="FirmwareVersion" Description="Indicates version of device firmware according to device manufacturer." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="FirstCurvatureRadius_0imKc0qX0HuO00025QrE$V" GlobalId="0imKc0qX0HuO00025QrE$V" Name="FirstCurvatureRadius" Description="FirstCurvatureRadius should be defined as the base or left side radius of curvature value." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="FirstCurvatureRadius_2996a0qX0HuO00025QrE$V" GlobalId="2996a0qX0HuO00025QrE$V" Name="FirstCurvatureRadius" Description="FirstCurvatureRadius should be defined as the base or left side radius of curvature value." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="FirstMullionOffset_3EXrkSznnAZeQvW3rVzop0" GlobalId="3EXrkSznnAZeQvW3rVzop0" Name="FirstMullionOffset" Description="Offset of the mullion centerline, measured along the x-axis of the window placement coordinate system. An offset value = 0.5 indicates that the mullion is positioned in the middle of the window." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="FirstTransomOffset_0bwI_yex59aARczKSEUAUL" GlobalId="0bwI_yex59aARczKSEUAUL" Name="FirstTransomOffset" Description="Offset of the transom centerline, measured along the z-axis of the window placement coordinate system. An offset value = 0.5 indicates that the transom is positioned in the middle of the window." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="FittingLossFactor_0jbxA0qVCHuO00025QrE$V" GlobalId="0jbxA0qVCHuO00025QrE$V" Name="FittingLossFactor" Description="A factor that determines the pressure loss due to friction through the fitting." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="FixedAnchorLength_3yEW81NlTADupBiIcyXmEa" GlobalId="3yEW81NlTADupBiIcyXmEa" Name="FixedAnchorLength" Description="Length of the anchor that is  grouted." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="FixingSocketHeight_2hbv60qT8HuO00025QrE$V" GlobalId="2hbv60qT8HuO00025QrE$V" Name="FixingSocketHeight" Description="The overall height of the fixing socket." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="FixingSocketThreadDiameter_2mzDm0qT8HuO00025QrE$V" GlobalId="2mzDm0qT8HuO00025QrE$V" Name="FixingSocketThreadDiameter" Description="The nominal diameter of the thread." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="FixingSocketThreadLength_2sKYQ0qT8HuO00025QrE$V" GlobalId="2sKYQ0qT8HuO00025QrE$V" Name="FixingSocketThreadLength" Description="The length of the threaded part of the fixing socket." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="FixingSocketTypeReference_2fDJU0qT8HuO00025QrE$V" GlobalId="2fDJU0qT8HuO00025QrE$V" Name="FixingSocketTypeReference" Description="Type reference for the fixing socket according to local standards." TemplateType="p_referencevalue" PrimaryMeasureType="IfcExternalReference" />
				<IfcSimplePropertyTemplate id="FixtureHeight_05M8M0qUmHuO00025QrE$V" GlobalId="05M8M0qUmHuO00025QrE$V" Name="FixtureHeight" Description="The height of the fixture, such as the text height of an exit sign." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="FlammabilityRating_0qOFu0qT0HuO00025QrE$V" GlobalId="0qOFu0qT0HuO00025QrE$V" Name="FlammabilityRating" Description="Flammability Rating for this object.
It is given according to the national building code that governs the rating of flammability for materials." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="FlammableStorage_0yYL_0qWaHuO00025QrE$V" GlobalId="0yYL_0qWaHuO00025QrE$V" Name="FlammableStorage" Description="Indication whether the space is intended to serve as a storage of flammable material (which is regarded as such by the presiding building code. (TRUE) indicates yes, (FALSE) otherwise." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="FlangeBaseFillet_2OueG0qVKHuO00025QrE$V" GlobalId="2OueG0qVKHuO00025QrE$V" Name="FlangeBaseFillet" Description="Flange base fillet of the profile." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNonNegativeLengthMeasure" />
				<IfcSimplePropertyTemplate id="FlangeChamfer_2IL0o0qVKHuO00025QrE$V" GlobalId="2IL0o0qVKHuO00025QrE$V" Name="FlangeChamfer" Description="Flange chamfer of the profile." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNonNegativeLengthMeasure" />
				<IfcSimplePropertyTemplate id="FlangeDepth_24deS0qVKHuO00025QrE$V" GlobalId="24deS0qVKHuO00025QrE$V" Name="FlangeDepth" Description="Flange depth of the profile." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="FlangeDiameter_2Y7Y60qV8HuO00025QrE$V" GlobalId="2Y7Y60qV8HuO00025QrE$V" Name="FlangeDiameter" Description="Overall diameter of the flange." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="FlangeDraft_2Czi80qVKHuO00025QrE$V" GlobalId="2Czi80qVKHuO00025QrE$V" Name="FlangeDraft" Description="Flange draft of the profile." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNonNegativeLengthMeasure" />
				<IfcSimplePropertyTemplate id="FlangeStandard_2Jq0M0qV8HuO00025QrE$V" GlobalId="2Jq0M0qV8HuO00025QrE$V" Name="FlangeStandard" Description="Designation of the standard describing the flange table." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="FlangeTable_2C4640qV8HuO00025QrE$V" GlobalId="2C4640qV8HuO00025QrE$V" Name="FlangeTable" Description="Designation of the standard table to which the flange conforms." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="FlangeThickness_2ftSO0qV8HuO00025QrE$V" GlobalId="2ftSO0qV8HuO00025QrE$V" Name="FlangeThickness" Description="Thickness of the material from which the pipe bend is constructed." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="FlangeTopFillet_2UFyw0qVKHuO00025QrE$V" GlobalId="2UFyw0qVKHuO00025QrE$V" Name="FlangeTopFillet" Description="Flange top fillet of the profile." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNonNegativeLengthMeasure" />
				<IfcSimplePropertyTemplate id="FloorAreaRatio_3TTni0qWSHuO00025QrE$V" GlobalId="3TTni0qWSHuO00025QrE$V" Name="FloorAreaRatio" Description="The ratio of all floor areas to the buildable area as the maximum floor area utilization of the site as a maximum value according to local building codes." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="FloorCovering_2$qVQcoWX429aMNJ7Te4Wn" GlobalId="2$qVQcoWX429aMNJ7Te4Wn" Name="FloorCovering" Description="Label to indicate the material or finish of the space flooring. The label is used for room book information and often displayed in room stamp.The material information is provided in absence of an IfcCovering (type=FLOORING) object with own shape representation and material assignment. In case of inconsistency the material assigned to IfcCovering elements takes precedence." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="FloorCoveringThickness_2MKCJJm7zCp9$O57i9dmav" GlobalId="2MKCJJm7zCp9$O57i9dmav" Name="FloorCoveringThickness" Description="Thickness of the material layer(s) for the space flooring.The thickness information is provided in absence of an IfcCovering (type=FLOORING) object with own shape representation. In cases of inconsistency between the geometric parameters of an assigned IfcCovering and this attached property, the geometric parameters take precedence." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="FlowArrangement_1mxIE0qUaHuO00025QrE$V" GlobalId="1mxIE0qUaHuO00025QrE$V" Name="FlowArrangement" Description="Defines the basic flow arrangements for the heat exchanger or cooler tower:

COUNTERFLOW: Air and water flow enter in different directions.
CROSSFLOW: Air and water flow are perpendicular.
PARALLELFLOW: Air and water flow enter in same directions.
MULTIPASS: Multipass flow heat exchanger arrangement.
OTHER: Other type of heat exchanger flow arrangement not defined above." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_HeatExchangerArrangement">
						<EnumerationValues>
							<IfcLabel-wrapper>COUNTERFLOW</IfcLabel-wrapper>
							<IfcLabel-wrapper>CROSSFLOW</IfcLabel-wrapper>
							<IfcLabel-wrapper>PARALLELFLOW</IfcLabel-wrapper>
							<IfcLabel-wrapper>MULTIPASS</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="FlowArrangement_264eG0qU8HuO00025QrE$V" GlobalId="264eG0qU8HuO00025QrE$V" Name="FlowArrangement" Description="Defines the basic flow arrangements for the heat exchanger or cooler tower:
COUNTERFLOW: Air and water flow enter in different directions.
CROSSFLOW: Air and water flow are perpendicular.
PARALLELFLOW: Air and water flow enter in same directions.
MULTIPASS: Multipass flow heat exchanger arrangement.
OTHER: Other type of heat exchanger flow arrangement not defined above." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_EvaporativeCoolerFlowArrangement">
						<EnumerationValues>
							<IfcLabel-wrapper>COUNTERFLOW</IfcLabel-wrapper>
							<IfcLabel-wrapper>CROSSFLOW</IfcLabel-wrapper>
							<IfcLabel-wrapper>PARALLELFLOW</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="FlowArrangement_29K4I0qSyHuO00025QrE$V" GlobalId="29K4I0qSyHuO00025QrE$V" Name="FlowArrangement" Description="Defines the basic flow arrangements for the heat exchanger or cooler tower:COUNTERFLOW: Air and water flow enter in different directions.
CROSSFLOW: Air and water flow are perpendicular.
PARALLELFLOW: Air and water flow enter in same directions.
MULTIPASS: Multipass flow heat exchanger arrangement. 
OTHER: Other type of heat exchanger flow arrangement not defined above." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_CoolingTowerFlowArrangement">
						<EnumerationValues>
							<IfcLabel-wrapper>COUNTERFLOW</IfcLabel-wrapper>
							<IfcLabel-wrapper>CROSSFLOW</IfcLabel-wrapper>
							<IfcLabel-wrapper>PARALLELFLOW</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="FlowClass_2gS5_0qUOHuO00025QrE$V" GlobalId="2gS5_0qUOHuO00025QrE$V" Name="FlowClass" Description="Alphanumeric indication of the flow class of a hydrant (may be used in connection with or instead of the FlowRate property)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="FlowCoefficient_24ORG0qXGHuO00025QrE$V" GlobalId="24ORG0qXGHuO00025QrE$V" Name="FlowCoefficient" Description="Flow coefficient (the quantity of fluid that passes through a fully open valve at unit pressure drop), typically expressed as the Kv or Cv value for the valve." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="FlowCondition_2WdoXb4UbD3vEHayBW5LaX" GlobalId="2WdoXb4UbD3vEHayBW5LaX" Name="FlowCondition" Description="Defines the flow condition as a percentage of the cross-sectional area." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="FlowConditionHistory_0vwzjJx0fC_vmMqxa_ItdJ" GlobalId="0vwzjJx0fC_vmMqxa_ItdJ" Name="FlowConditionHistory" Description="Defines the flow condition as a percentage of the cross-sectional area." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="FlowControlType_0gDmE0qS0HuO00025QrE$V" GlobalId="0gDmE0qS0HuO00025QrE$V" Name="FlowControlType" Description="Type of flow control element that may be included as a part of the construction of the air terminal." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_AirTerminalFlowControlType">
						<EnumerationValues>
							<IfcLabel-wrapper>DAMPER</IfcLabel-wrapper>
							<IfcLabel-wrapper>BELLOWS</IfcLabel-wrapper>
							<IfcLabel-wrapper>NONE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="FlowLoading_1N4dPw9IT6AvWCtPogKQA_" GlobalId="1N4dPw9IT6AvWCtPogKQA_" Name="FlowLoading" Description="Flow loading force" TemplateType="p_singlevalue" PrimaryMeasureType="IfcForceMeasure" />
				<IfcSimplePropertyTemplate id="FlowMeterPurpose_3pTEE0qUSHuO00025QrE$V" GlobalId="3pTEE0qUSHuO00025QrE$V" Name="FlowMeterPurpose" Description="Enumeration defining the purpose of the flow meter occurrence." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_FlowMeterPurpose">
						<EnumerationValues>
							<IfcLabel-wrapper>MASTER</IfcLabel-wrapper>
							<IfcLabel-wrapper>SUBMASTER</IfcLabel-wrapper>
							<IfcLabel-wrapper>SUBMETER</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="FlowPattern_2YKFc0qRyHuO00025QrE$V" GlobalId="2YKFc0qRyHuO00025QrE$V" Name="FlowPattern" Description="Flow pattern." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_AirTerminalFlowPattern">
						<EnumerationValues>
							<IfcLabel-wrapper>LINEARSINGLE</IfcLabel-wrapper>
							<IfcLabel-wrapper>LINEARDOUBLE</IfcLabel-wrapper>
							<IfcLabel-wrapper>LINEARFOURWAY</IfcLabel-wrapper>
							<IfcLabel-wrapper>RADIAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>SWIRL</IfcLabel-wrapper>
							<IfcLabel-wrapper>DISPLACMENT</IfcLabel-wrapper>
							<IfcLabel-wrapper>COMPACTJET</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Flowrate_1wFslkM110DwcNqSBBrefD" GlobalId="1wFslkM110DwcNqSBBrefD" Name="Flowrate" Description="The flowrate of the fluid." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcMassFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="Flowrate_2pRIi0qVuHuO00025QrE$V" GlobalId="2pRIi0qVuHuO00025QrE$V" Name="Flowrate" Description="The flowrate of the fluid." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="FlowrateLeakage_3XJ7A0qV8HuO00025QrE$V" GlobalId="3XJ7A0qV8HuO00025QrE$V" Name="FlowrateLeakage" Description="Leakage flowrate versus pressure difference." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="FlowRateRange_3KpXS0qVuHuO00025QrE$V" GlobalId="3KpXS0qVuHuO00025QrE$V" Name="FlowRateRange" Description="Allowable range of volume of fluid being pumped against the resistance specified." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcMassFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="FlowRateRange_3Zz9i0qUKHuO00025QrE$V" GlobalId="3Zz9i0qUKHuO00025QrE$V" Name="FlowRateRange" Description="Allowable range of volume of fluid being pumped against the resistance specified." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="FlowRating_3q4tS0qVCHuO00025QrE$V" GlobalId="3q4tS0qVCHuO00025QrE$V" Name="FlowRating" Description="Actual flow capacity for the gutter. Value of 0.00 means this value has not been set." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="FlowResistanceRange_3RzIK0qVuHuO00025QrE$V" GlobalId="3RzIK0qVuHuO00025QrE$V" Name="FlowResistanceRange" Description="Allowable range of frictional resistance against which the fluid is being pumped." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="FluidFlowLeakage_1QZPg0qTuHuO00025QrE$V" GlobalId="1QZPg0qTuHuO00025QrE$V" Name="FluidFlowLeakage" Description="Volumetric leakage flow rate." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="FluidFlowLeakage_27c7W0qVCHuO00025QrE$V" GlobalId="27c7W0qVCHuO00025QrE$V" Name="FluidFlowLeakage" Description="Volumetric leakage flow rate." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="FluidPressureRange_3S9ls0qSaHuO00025QrE$V" GlobalId="3S9ls0qSaHuO00025QrE$V" Name="FluidPressureRange" Description="Allowable water working pressure range inside the tube." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="FlushingRate_3i5$y0qXGHuO00025QrE$V" GlobalId="3i5$y0qXGHuO00025QrE$V" Name="FlushingRate" Description="The predetermined quantity of water to be flushed." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="FlushRate_2LeSK0qW8HuO00025QrE$V" GlobalId="2LeSK0qW8HuO00025QrE$V" Name="FlushRate" Description="The minimum and maximum volume of water used at each flush. Where a single flush is used, the value of upper bound and lower bound should be equal. For a dual flush toilet, the lower bound should be used for the lesser flush rate and the upper bound for the greater flush rate. Where flush is achieved using mains pressure water through a flush valve, the value of upper and lower bound should be equal and should be the same as the flush rate property of the flush valve (see relevant valve property set). Alternatively, in this case, do not assert the flush rate property; refer to the flush rate of the flush valve." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcVolumeMeasure" />
				<IfcSimplePropertyTemplate id="FlushType_24yKy0qW8HuO00025QrE$V" GlobalId="24yKy0qW8HuO00025QrE$V" Name="FlushType" Description="The property enumeration Pset_FlushTypeEnum defines the types of flushing mechanism that may be specified for cisterns and sanitary terminals where:-

Lever:  Flushing is achieved by twisting a lever that causes a predetermined flow of water to be passed from a cistern to the sanitary terminal.
Pull:   Flushing is achieved by pulling a handle or knob vertically upwards that causes a predetermined flow of water to be passed from a cistern to the sanitary terminal.
Push:   Flushing is achieved by pushing a button or plate that causes a predetermined flow of water to be passed from a cistern to the sanitary terminal.
Sensor: Flush is activated through an automatic sensing mechanism." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_FlushType">
						<EnumerationValues>
							<IfcLabel-wrapper>LEVER</IfcLabel-wrapper>
							<IfcLabel-wrapper>PULL</IfcLabel-wrapper>
							<IfcLabel-wrapper>PUSH</IfcLabel-wrapper>
							<IfcLabel-wrapper>SENSOR</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="FoldType_1CiTInSyDDw8cLG6539eAN" GlobalId="1CiTInSyDDw8cLG6539eAN" Name="FoldType" Description="Types of Geological Folds, which can be classified according to various factors independently." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="FootOfArches_2qRbpwn216hwkxu4hPpUVh" GlobalId="2qRbpwn216hwkxu4hPpUVh" Name="FootOfArches" Description="Specifies the type of vertical structure upon which the lower part of the arch leans onto." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="Force_27VOM0qRqHuO00025QrE$V" GlobalId="27VOM0qRqHuO00025QrE$V" Name="Force" Description="Indicates the maximum close-off force for the actuator." TemplateType="p_singlevalue" PrimaryMeasureType="IfcForceMeasure" />
				<IfcSimplePropertyTemplate id="ForeignObjectDetectionSensorType_3ev2SAoQX3Lgt5$_Dbrj6Q" GlobalId="3ev2SAoQX3Lgt5$_Dbrj6Q" Name="ForeignObjectDetectionSensorType" Description="Indicates the type of foreign object detection sensor." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ForeignObjectDetectionSensorType">
						<EnumerationValues>
							<IfcLabel-wrapper>DUALPOWERNETWORK</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="FormStrippingStrength_2x9z80qVGHuO00025QrE$V" GlobalId="2x9z80qVGHuO00025QrE$V" Name="FormStrippingStrength" Description="The minimum required compressive strength of the concrete at form stripping time." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="FoulingFactor_1rUW80qX8HuO00025QrE$V" GlobalId="1rUW80qX8HuO00025QrE$V" Name="FoulingFactor" Description="Fouling factor of the tubes in the tube bundle." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermalResistanceMeasure" />
				<IfcSimplePropertyTemplate id="FountainType_2xBiw0qW8HuO00025QrE$V" GlobalId="2xBiw0qW8HuO00025QrE$V" Name="FountainType" Description="Selection of the type of fountain from the enumerated list of types where:-

DrinkingWater:  Sanitary appliance that provides a low pressure jet of drinking water.
Eyewash:    Waste water appliance, usually installed in work places where there is a risk of injury to eyes by solid particles or dangerous liquids, with which the user can wash the eyes without touching them." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_FountainType">
						<EnumerationValues>
							<IfcLabel-wrapper>DRINKINGWATER</IfcLabel-wrapper>
							<IfcLabel-wrapper>EYEWASH</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="FractionConvectiveHeatTransfer_2SW0O0qWaHuO00025QrE$V" GlobalId="2SW0O0qWaHuO00025QrE$V" Name="FractionConvectiveHeatTransfer" Description="Fraction of the total heat transfer rate as the convective heat transfer." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="FractionOfMotorHeatToAirStream_0D52m0qUGHuO00025QrE$V" GlobalId="0D52m0qUGHuO00025QrE$V" Name="FractionOfMotorHeatToAirStream" Description="Fraction of the motor heat released into the fluid flow." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="FractionRadiantHeatTransfer_2Q7Qm0qWaHuO00025QrE$V" GlobalId="2Q7Qm0qWaHuO00025QrE$V" Name="FractionRadiantHeatTransfer" Description="Fraction of the total heat transfer rate as the radiant heat transfer." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="FractureIndex_2g$diqZkvF5QTVAB4_JcMO" GlobalId="2g$diqZkvF5QTVAB4_JcMO" Name="FractureIndex" Description="Count of the number or spacing of fractures over an arbitrary length of core." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="FragilityRating_0vlaY0qT0HuO00025QrE$V" GlobalId="0vlaY0qT0HuO00025QrE$V" Name="FragilityRating" Description="Indication on the fragility of the covering (e.g., under fire conditions).  It is given according to the national building code that might provide a classification for fragility." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="FrameDepth_0IwU5LmKj0KPHgy8pFmJVV" GlobalId="0IwU5LmKj0KPHgy8pFmJVV" Name="FrameDepth" Description="The length (or depth) of the frame.

For a permeable covering, it is the depth of panel frame (used to include the permeable covering), measured from front face to back face horizontally (i.e. perpendicular to the window or door elevation plane)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="FrameDepth_2B6mU0qT4HuO00025QrE$V" GlobalId="2B6mU0qT4HuO00025QrE$V" Name="FrameDepth" Description="The length (or depth) of the frame.

For a damper, it is the length (or depth) of the damper frame." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="FrameDepth_2CF8ENszP0TfWSzgwCUWWp" GlobalId="2CF8ENszP0TfWSzgwCUWWp" Name="FrameDepth" Description="The length (or depth) of the frame.

For a window, it is the depth of panel frame, measured from front face to back face horizontally (i.e. perpendicular to the window elevation plane)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="FrameMaterial_1ZDPy0qUKHuO00025QrE$V" GlobalId="1ZDPy0qUKHuO00025QrE$V" Name="FrameMaterial" Description="Filter frame material." TemplateType="p_referencevalue" PrimaryMeasureType="IfcMaterialDefinition" />
				<IfcSimplePropertyTemplate id="FrameSize_0FmL80qU4HuO00025QrE$V" GlobalId="0FmL80qU4HuO00025QrE$V" Name="FrameSize" Description="Designation of the frame size according to the named range of frame sizes designated at the place of use or according to a given standard." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="FrameThickness_2EJVRwHkn2zAJrpCfm_8dS" GlobalId="2EJVRwHkn2zAJrpCfm_8dS" Name="FrameThickness" Description="The thickness of the frame.

For a permeable covering, it is the width of panel frame (used to include the permeable covering), measured from inside of panel (at permeable covering) to outside of panel (at lining), i.e. parallel to the window or door (elevation) plane." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="FrameThickness_2JSqA0qT4HuO00025QrE$V" GlobalId="2JSqA0qT4HuO00025QrE$V" Name="FrameThickness" Description="The thickness of the frame.

For a damper, it is the thickness of the damper frame material." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="FrameThickness_2WtA1SnpvExvPSRzEemyhx" GlobalId="2WtA1SnpvExvPSRzEemyhx" Name="FrameThickness" Description="The thickness of the frame.

For a window, it is the width of panel frame, measured from inside of panel (at glazing) to outside of panel (at lining), i.e. parallel to the window (elevation) plane." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="FrameType_259IQ0qT4HuO00025QrE$V" GlobalId="259IQ0qT4HuO00025QrE$V" Name="FrameType" Description="The type of frame used by the damper (e.g., Standard, Single Flange, Single Reversed Flange, Double Flange, etc.)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="FreeAnchorLength_0S210oTSH9qA4UjE0XGK_m" GlobalId="0S210oTSH9qA4UjE0XGK_m" Name="FreeAnchorLength" Description="Length of the anchor that is not grouted." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="FreezingPoint_0HtTs0qUuHuO00025QrE$V" GlobalId="0HtTs0qUuHuO00025QrE$V" Name="FreezingPoint" Description="The freezing point of the material (fluid)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="FrequencyResponse_30kFG0qSCHuO00025QrE$V" GlobalId="30kFG0qSCHuO00025QrE$V" Name="FrequencyResponse" Description="Indicates the output over a specified range of frequencies." TemplateType="p_tablevalue" PrimaryMeasureType="IfcFrequencyMeasure" SecondaryMeasureType="IfcSoundPowerMeasure" />
				<IfcSimplePropertyTemplate id="FrictionAngle_1sDVHNRT5F8O5O9TVdOgO5" GlobalId="1sDVHNRT5F8O5O9TVdOgO5" Name="FrictionAngle" Description="Derived from the Mohr-Coulomb failure criterion and used to describe the friction shear resistance of ground materials, together with the normal effective stress." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="FrictionAngle_1XV$MSCjTDXgy6O1qRcwC4" GlobalId="1XV$MSCjTDXgy6O1qRcwC4" Name="FrictionAngle" Description="Friction angle is the tested inclination angle from horizontal." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="FrictionAngle_3D7neWa7f4ih$KjXeaqaqO" GlobalId="3D7neWa7f4ih$KjXeaqaqO" Name="FrictionAngle" Description="Derived from the Mohr-Coulomb failure criterion and used to describe the friction shear resistance of ground materials, together with the normal effective stress." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="FrictionBehaviour_2hk0eZaUv0hgmvkItMOeJC" GlobalId="2hk0eZaUv0hgmvkItMOeJC" Name="FrictionBehaviour" Description="Friction shear strength of a rock or soil that is dependent on interparticle friction." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="FrictionCoefficient_1FHgJZeI9AQvoFPcY4HmIA" GlobalId="1FHgJZeI9AQvoFPcY4HmIA" Name="FrictionCoefficient" Description="The friction coefficient between tendon and tendon sheet while the tendon is unbonded." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="FrictionHeatGain_3$1U60qSeHuO00025QrE$V" GlobalId="3$1U60qSeHuO00025QrE$V" Name="FrictionHeatGain" Description="Friction heat gain." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="FrictionLoss_3OJwS0qTeHuO00025QrE$V" GlobalId="3OJwS0qTeHuO00025QrE$V" Name="FrictionLoss" Description="The pressure loss due to friction per unit length. (Data type = PressureMeasure/LengthMeasure)" TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="Fuel_3tjlO0qXCHuO00025QrE$V" GlobalId="3tjlO0qXCHuO00025QrE$V" Name="Fuel" Description="The amount of fuel consumed during the period specified in the time series." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcVolumeMeasure" />
				<IfcSimplePropertyTemplate id="FullLoadRatio_05b5a0qSiHuO00025QrE$V" GlobalId="05b5a0qSiHuO00025QrE$V" Name="FullLoadRatio" Description="Ratio of actual power to full load power as a quadratic function of part load, at certain condensing and evaporating temperature, FracFullLoadPower = f ( PartLoadRatio)." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="FullLoadRatioCurve_0lvHS0qSaHuO00025QrE$V" GlobalId="0lvHS0qSaHuO00025QrE$V" Name="FullLoadRatioCurve" Description="Ratio of actual power to full load power as a quadratic function of part load, at certain condensing and evaporating temperature, FracFullLoadPower = f ( PartLoadRatio)." TemplateType="p_tablevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" SecondaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="FullScaleOutput_2WLErKhy1AxhskSWPS52wJ" GlobalId="2WLErKhy1AxhskSWPS52wJ" Name="FullScaleOutput" Description="Indicates the full scale output of the earthquake sensor or accelerometer." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLinearVelocityMeasure" />
				<IfcSimplePropertyTemplate id="Function_0moNa0qSWHuO00025QrE$V" GlobalId="0moNa0qSWHuO00025QrE$V" Name="Function" Description="Type of function for which the conductor is intended." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_FunctionEnum">
						<EnumerationValues>
							<IfcLabel-wrapper>LINE</IfcLabel-wrapper>
							<IfcLabel-wrapper>NEUTRAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>PROTECTIVEEARTH</IfcLabel-wrapper>
							<IfcLabel-wrapper>PROTECTIVEEARTHNEUTRAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="FunctionalUnitReference_28A1C0qU4HuO00025QrE$V" GlobalId="28A1C0qU4HuO00025QrE$V" Name="FunctionalUnitReference" Description="Reference to a database or a classification" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="FunctionReliable_2bJ_W0qSSHuO00025QrE$V" GlobalId="2bJ_W0qSSHuO00025QrE$V" Name="FunctionReliable" Description="Element (such as cable, bus, core) maintain given properties/functions over a given (tested) time and conditions. According to IEC standard." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="FundingSource_2Z2eDnN418DOpcmbgckN0p" GlobalId="2Z2eDnN418DOpcmbgckN0p" Name="FundingSource" Description="Investment funding source" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="FurniturePanelType_1AGUE0qWyHuO00025QrE$V" GlobalId="1AGUE0qWyHuO00025QrE$V" Name="FurniturePanelType" Description="Available panel types from which that required may be selected." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" id="i1240" Name="PEnum_FurniturePanelType">
						<EnumerationValues>
							<IfcLabel-wrapper>ACOUSTICAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>GLAZED</IfcLabel-wrapper>
							<IfcLabel-wrapper>HORZ_SEG</IfcLabel-wrapper>
							<IfcLabel-wrapper>MONOLITHIC</IfcLabel-wrapper>
							<IfcLabel-wrapper>OPEN</IfcLabel-wrapper>
							<IfcLabel-wrapper>ENDS</IfcLabel-wrapper>
							<IfcLabel-wrapper>DOOR</IfcLabel-wrapper>
							<IfcLabel-wrapper>SCREEN</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="FuseDisconnectorType_3pVzu0qVqHuO00025QrE$V" GlobalId="3pVzu0qVqHuO00025QrE$V" Name="FuseDisconnectorType" Description="A list of the available types of fuse disconnector from which that required may be selected where:

EngineProtectionDevice: A fuse whose characteristic is specifically designed for the protection of a motor or generator.
FuseSwitchDisconnector: A switch disconnector in which a fuse link or a fuse carrier with fuse link forms the moving contact,
HRC: A standard fuse (High Rupturing Capacity)
OverloadProtectionDevice: A device that disconnects the supply when the operating conditions in an electrically undamaged circuit causes an overcurrent,
SemiconductorFuse: A fuse whose characteristic is specifically designed for the protection of sem-conductor devices.
SwitchDisconnectorFuse: A switch disconnector in which one or more poles have a fuse in series in a composite unit." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_FuseDisconnectorType">
						<EnumerationValues>
							<IfcLabel-wrapper>ENGINEPROTECTIONDEVICE</IfcLabel-wrapper>
							<IfcLabel-wrapper>FUSEDSWITCH</IfcLabel-wrapper>
							<IfcLabel-wrapper>HRC</IfcLabel-wrapper>
							<IfcLabel-wrapper>OVERLOADPROTECTIONDEVICE</IfcLabel-wrapper>
							<IfcLabel-wrapper>SWITCHDISCONNECTORFUSE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="FusibleLinkTemperature_0BsWE0qT8HuO00025QrE$V" GlobalId="0BsWE0qT8HuO00025QrE$V" Name="FusibleLinkTemperature" Description="The temperature that the fusible link melts." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="FusibleLinkTemperature_3SAlk0qT4HuO00025QrE$V" GlobalId="3SAlk0qT4HuO00025QrE$V" Name="FusibleLinkTemperature" Description="The temperature that the fusible link melts." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="GammaRay_0uQOo2p7L7gfdVTXwVzLwb" GlobalId="0uQOo2p7L7gfdVTXwVzLwb" Name="GammaRay" Description="Naturally occurring gamma radiation which characterizes the rock or sediment in a borehole or drill hole, measured by a gamma ray logging." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="GasConcentration_2PG$JI90zDQPVTLSZVlkZv" GlobalId="2PG$JI90zDQPVTLSZVlkZv" Name="GasConcentration" Description="Expected concentration of gas to be encountered during excavation." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="GasConcentration_39aIOtx2DEa802QYg_FsGV" GlobalId="39aIOtx2DEa802QYg_FsGV" Name="GasConcentration" Description="Expected concentration of gas to be encountered during excavation." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="GasDetected_192xa0qWKHuO00025QrE$V" GlobalId="192xa0qWKHuO00025QrE$V" Name="GasDetected" Description="Identification of the gas that is being detected, according to chemical formula. For example, carbon monoxide is &apos;CO&apos;, carbon dioxide is &apos;CO2&apos;, oxygen is &apos;O2&apos;." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="GasPressure_0qky80qUqHuO00025QrE$V" GlobalId="0qky80qUqHuO00025QrE$V" Name="GasPressure" Description="Fill pressure (e.g. for between-pane gas fills): the pressure exerted by a mass of gas confined in a constant volume." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="GasType_0i7RYafnT6WPVPIwyUyF1u" GlobalId="0i7RYafnT6WPVPIwyUyF1u" Name="GasType" Description="Type of natural gas occurence in the subject section." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="GasType_1CtHA0qUWHuO00025QrE$V" GlobalId="1CtHA0qUWHuO00025QrE$V" Name="GasType" Description="Defines the types of gas that may be specified." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_GasType">
						<EnumerationValues>
							<IfcLabel-wrapper>COMMERCIALBUTANE</IfcLabel-wrapper>
							<IfcLabel-wrapper>COMMERCIALPROPANE</IfcLabel-wrapper>
							<IfcLabel-wrapper>LIQUEFIEDPETROLEUMGAS</IfcLabel-wrapper>
							<IfcLabel-wrapper>NATURALGAS</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="GasType_3xONOgIiDFaPnwg2ne4hqt" GlobalId="3xONOgIiDFaPnwg2ne4hqt" Name="GasType" Description="Type of natural gas occurence in subject section." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="GeoContactType_0cv0MyVAnAzeuvZv_LHADf" GlobalId="0cv0MyVAnAzeuvZv_LHADf" Name="GeoContactType" Description="Reports a URI referring to a controlled concept from a vocabulary defining the contact types." TemplateType="p_singlevalue" PrimaryMeasureType="IfcIdentifier" />
				<IfcSimplePropertyTemplate id="GeologicalFormation_2bpjqV7bf5FRh$hybIccDv" GlobalId="2bpjqV7bf5FRh$hybIccDv" Name="GeologicalFormation" Description="A geological formation, or simply formation, is a body of rock with a consistent set of physical characteristics (lithology) that distinguishes it from adjacent bodies of rock, and which occupies a particular position in the layers of rock exposed in a geographical region (the stratigraphic column)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="GeologicalHazard_3j7ItBCun2pf_7JPhtV8eb" GlobalId="3j7ItBCun2pf_7JPhtV8eb" Name="GeologicalHazard" Description="Relates the presence or absence of a certain geological hazard, like e.g. hazardous minerals (asbestos, serpentine) or gas." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="GeologicalStrengthIndex_1mKh3XC4vAkAZD1jzmwtzK" GlobalId="1mKh3XC4vAkAZD1jzmwtzK" Name="GeologicalStrengthIndex" Description="The Geological Strength Index (GSI): A characterization tool for assessing engineering properties for rock masses. 
See also [GSI](https://static.rocscience.cloud/assets/resources/learning/hoek/2019-The-Hoek-Brown-failure-criterion-and-GSI-2018-edition-1.pdf)." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcInteger" />
				<IfcSimplePropertyTemplate id="GeologicHistory_1iHvbtNqf6U9Bzcl_08dUS" GlobalId="1iHvbtNqf6U9Bzcl_08dUS" Name="GeologicHistory" Description="Human readable description, possibly formatted with formal syntax, of the age of the GeologicUnit (where age is a sequence of events and may include process and environment information)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="GeologicUnitType_3kvkEL4rr7TelKN6g8aSiF" GlobalId="3kvkEL4rr7TelKN6g8aSiF" Name="GeologicUnitType" Description="&gt;NOTE Definition according to GeoSciML: The type of GeologicUnit." TemplateType="p_singlevalue" PrimaryMeasureType="IfcIdentifier" />
				<IfcSimplePropertyTemplate id="GeologyCode_1haXibmFT39BKx1k_TwkeU" GlobalId="1haXibmFT39BKx1k_TwkeU" Name="GeologyCode" Description="Reference to any existing classification, e.g. from ageological survey or stratigraphy table." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="GlassColour_18zyC0qTqHuO00025QrE$V" GlobalId="18zyC0qTqHuO00025QrE$V" Name="GlassColour" Description="Colour (tint) selection for this glazing. It is given for information purposes only." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="GlassLayers_0DzO_0qTqHuO00025QrE$V" GlobalId="0DzO_0qTqHuO00025QrE$V" Name="GlassLayers" Description="Number of glass layers within the frame. E.g. &quot;2&quot; for double glazing." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="GlassThickness1_0QUUW0qTqHuO00025QrE$V" GlobalId="0QUUW0qTqHuO00025QrE$V" Name="GlassThickness1" Description="Thickness of the first (inner) glass layer." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="GlassThickness2_0dbjS0qTqHuO00025QrE$V" GlobalId="0dbjS0qTqHuO00025QrE$V" Name="GlassThickness2" Description="Thickness of the second (intermediate or outer) glass layer." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="GlassThickness3_0oKMm0qTqHuO00025QrE$V" GlobalId="0oKMm0qTqHuO00025QrE$V" Name="GlassThickness3" Description="Thickness of the third (outer) glass layer." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="GlazingAreaFraction_1TXuk0qTmHuO00025QrE$V" GlobalId="1TXuk0qTmHuO00025QrE$V" Name="GlazingAreaFraction" Description="Fraction of the glazing area relative to the total area of the filling element.
It shall be used, if the glazing area is not given separately for all panels within the filling element." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="GlazingAreaFraction_3TCqk0qXWHuO00025QrE$V" GlobalId="3TCqk0qXWHuO00025QrE$V" Name="GlazingAreaFraction" Description="Fraction of the glazing area relative to the total area of the filling element.
It shall be used, if the glazing area is not given separately for all panels within the filling element." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="GlobalTradeItemNumber_1u_fA0qUmHuO00025QrE$V" GlobalId="1u_fA0qUmHuO00025QrE$V" Name="GlobalTradeItemNumber" Description="The Global Trade Item Number (GTIN) is an identifier for trade items developed by GS1 (www.gs1.org)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcIdentifier" />
				<IfcSimplePropertyTemplate id="Gradient_1pL7i0qVCHuO00025QrE$V" GlobalId="1pL7i0qVCHuO00025QrE$V" Name="Gradient" Description="The gradient of the pipe segment." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="Grading_3hHDlpC554pggyHq6uRDZ7" GlobalId="3hHDlpC554pggyHq6uRDZ7" Name="Grading" Description="Grading of the material." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="GrainSize_1HTwj3_Z583xdSnaDCG6Bx" GlobalId="1HTwj3_Z583xdSnaDCG6Bx" Name="GrainSize" Description="Grain size diameter." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="GravelVolume_2PeYcOedfAx9gaB4_6ou2V" GlobalId="2PeYcOedfAx9gaB4_6ou2V" Name="GravelVolume" Description="Relative volume of gravel (typically larger than 2mm) stratum constituents." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumeMeasure" />
				<IfcSimplePropertyTemplate id="GrossPlannedArea_00xfM0qWaHuO00025QrE$V" GlobalId="00xfM0qWaHuO00025QrE$V" Name="GrossPlannedArea" Description="Total planned gross area of the spatial structure element. Used for programming the spatial structure element." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAreaMeasure" />
				<IfcSimplePropertyTemplate id="GrossPlannedArea_0L4AE0qSKHuO00025QrE$V" GlobalId="0L4AE0qSKHuO00025QrE$V" Name="GrossPlannedArea" Description="Total planned gross area of the spatial structure element. Used for programming the spatial structure element." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAreaMeasure" />
				<IfcSimplePropertyTemplate id="GrossPlannedArea_3aRdaISbH6VwiKDVpXGI6$" GlobalId="3aRdaISbH6VwiKDVpXGI6$" Name="GrossPlannedArea" Description="Total planned gross area of the spatial structure element. Used for programming the spatial structure element." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAreaMeasure" />
				<IfcSimplePropertyTemplate id="GroundClassTBM_1_Vnw4BBXCOA6hWdCFm02c" GlobalId="1_Vnw4BBXCOA6hWdCFm02c" Name="GroundClassTBM" Description="Specific rock mass classification based on TBM data." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel " />
				<IfcSimplePropertyTemplate id="GroundFaultCurrentSetValue_3muRcKEG13Eekov69fIrNH" GlobalId="3muRcKEG13Eekov69fIrNH" Name="GroundFaultCurrentSetValue" Description="Ground fault current set value. The set value of the ground tripping current if adjustable." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="GroundFaultFunction_2ACC9nT6bAfuCPw3yJtgyK" GlobalId="2ACC9nT6bAfuCPw3yJtgyK" Name="GroundFaultFunction" Description="Applying ground fault function. A flag indicating that the ground fault function of the device is used. The value should be set to FALSE for devices not having a ground fault function, or if the ground fault function is not selected to be used." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="GroundFaulti2tFunction_015H08Upv8IgOnOdu__Psm" GlobalId="015H08Upv8IgOnOdu__Psm" Name="GroundFaulti2tFunction" Description="Applying ground fault i2t function. A flag indicating that the I2t ground fault function of the device is used. The value should be set to TRUE only if the I2t function is explicitly selected for the device." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="GroundFaultTrippingTime_1QKaWg0bX6NwHynHAaPmFn" GlobalId="1QKaWg0bX6NwHynHAaPmFn" Name="GroundFaultTrippingTime" Description="Ground fault tripping time. The set value of the ground fault tripping current if adjustable." TemplateType="p_singlevalue" PrimaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="GroundingType_0GRwj6SjTAtwY3611gVZUL" GlobalId="0GRwj6SjTAtwY3611gVZUL" Name="GroundingType" Description="The type of grounding connection." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="GroundPressure_1jBfqbXjz0bBfljBTynV2j" GlobalId="1jBfqbXjz0bBfljBTynV2j" Name="GroundPressure" Description="Pressure at the nozzle." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="GroundResistance_2NdoXdKT98XeEMmk8dSBQF" GlobalId="2NdoXdKT98XeEMmk8dSBQF" Name="GroundResistance" Description="The soil or ground resistance to electrical current from the cable fitting." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricResistanceMeasure" />
				<IfcSimplePropertyTemplate id="GroundTemperature_2lSWAaqvfDPgf2dncsUHxG" GlobalId="2lSWAaqvfDPgf2dncsUHxG" Name="GroundTemperature" Description="Ground temperature expected in the subject section." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="GroundTemperature_3iQRoUZRb2nOp0QHhQ7OX4" GlobalId="3iQRoUZRb2nOp0QHhQ7OX4" Name="GroundTemperature" Description="Ground temperature expected in the subject section." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="GroundwaterAgressiveness_0eilySCHX2FwvuWJBgvmtA" GlobalId="0eilySCHX2FwvuWJBgvmtA" Name="GroundwaterAgressiveness" Description="Rating of the agressiveness e.g. towards concrete." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="GroundwaterAgressiveness_0mQnX78kz9AByN_68nPESp" GlobalId="0mQnX78kz9AByN_68nPESp" Name="GroundwaterAgressiveness" Description="Rating of the agressiveness e.g. towards concrete, according to national standards." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="GroundwaterDepth_2LavVwNED3BwVZy6EdS6e4" GlobalId="2LavVwNED3BwVZy6EdS6e4" Name="GroundwaterDepth" Description="Depth groundwater encountered (boreholeML)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="GroundwaterDesignPressure_2Yt2lRKNn8Nw8eA8RdSylB" GlobalId="2Yt2lRKNn8Nw8eA8RdSylB" Name="GroundwaterDesignPressure" Description="Groundwater pressure to be considered in the design." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="GroundwaterTemperature_3IMyTWYAj0SuSW8M3JUwRd" GlobalId="3IMyTWYAj0SuSW8M3JUwRd" Name="GroundwaterTemperature" Description="Groundwater temperature observed at specific location or expected in the subject section." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="GroupCode_0TZSm0qWyHuO00025QrE$V" GlobalId="0TZSm0qWyHuO00025QrE$V" Name="GroupCode" Description="e.g. panels, worksurfaces, storage, etc." TemplateType="p_singlevalue" PrimaryMeasureType="IfcIdentifier" />
				<IfcSimplePropertyTemplate id="GroutBodyDiameter_25qec0hKPDaBiR1Qtt66DX" GlobalId="25qec0hKPDaBiR1Qtt66DX" Name="GroutBodyDiameter" Description="Grout body diameter." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="GroutBodyDiameter_2PVUuyOXLDSgXbqEVZOPKv" GlobalId="2PVUuyOXLDSgXbqEVZOPKv" Name="GroutBodyDiameter" Description="Grout body diameter." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="GroutBodyLength_35IXCwXjn6DBMNwtA1JvqK" GlobalId="35IXCwXjn6DBMNwtA1JvqK" Name="GroutBodyLength" Description="Length of the grout body." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="GroutingType_2gToDgdT90Pvu0v1XANdjJ" GlobalId="2gToDgdT90Pvu0v1XANdjJ" Name="GroutingType" Description="Type of grouting used." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_GroutingType">
						<EnumerationValues>
							<IfcLabel-wrapper>STDGROUTING_CEMENT</IfcLabel-wrapper>
							<IfcLabel-wrapper>MICROFINE_CEMENT</IfcLabel-wrapper>
							<IfcLabel-wrapper>ULTRAFINE_CEMENT</IfcLabel-wrapper>
							<IfcLabel-wrapper>CHEMICAL_COMPONENT</IfcLabel-wrapper>
							<IfcLabel-wrapper>USERDEFINED</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="GSI_0fHcCs3y9Fd95xSlbHGb0C" GlobalId="0fHcCs3y9Fd95xSlbHGb0C" Name="GSI" Description="The Geological Strength Index (GSI): A characterization tool for assessing engineering properties for rock masses." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveInteger" />
				<IfcSimplePropertyTemplate id="GSI_0jXoIJ8Fz6WuI01oi0uMuh" GlobalId="0jXoIJ8Fz6WuI01oi0uMuh" Name="GSI" Description="The Geological Strength Index (GSI): A characterization tool for assessing engineering properties for rock masses.
  &gt;NOTE Definition from Marinos &amp; Hoek (2000) GSI: A Geologically Friendly Tool For Rock Mass Strength Estimation. [Link](https://static.rocscience.cloud/assets/resources/learning/hoek/2000-GSI-A-Geologically-Friendly-Tool-for-Rock-Mass-Strength-Estimation.pdf)" TemplateType="p_boundedvalue" PrimaryMeasureType="IfcInteger" />
				<IfcSimplePropertyTemplate id="GuardRailConnection_1e7Nb8No96yQH99WQ23C68" GlobalId="1e7Nb8No96yQH99WQ23C68" Name="GuardRailConnection" Description="Indicates how the guard rail is connected along its length, when the fasteners are not explicitly modelled." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_GuardRailConnection">
						<EnumerationValues>
							<IfcLabel-wrapper>FISHPLATE</IfcLabel-wrapper>
							<IfcLabel-wrapper>WELD</IfcLabel-wrapper>
							<IfcLabel-wrapper>NONE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="GuardRailType_2pyysGb8D26hJVn4mkBF6i" GlobalId="2pyysGb8D26hJVn4mkBF6i" Name="GuardRailType" Description="Type of the guard rail." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_GuardRailType">
						<EnumerationValues>
							<IfcLabel-wrapper>GUARDRAILSONLY</IfcLabel-wrapper>
							<IfcLabel-wrapper>GUARDRAILANDSPOTSLEEPERS</IfcLabel-wrapper>
							<IfcLabel-wrapper>SPOTSLEEPERSONLY</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="GullyType_137jE0qXSHuO00025QrE$V" GlobalId="137jE0qXSHuO00025QrE$V" Name="GullyType" Description="Identifies the predefined types of gully from which the type required may be set." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" id="i1304" Name="PEnum_GullyType">
						<EnumerationValues>
							<IfcLabel-wrapper>VERTICAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>BACKINLET</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="GullyType_382Uq0qXSHuO00025QrE$V" GlobalId="382Uq0qXSHuO00025QrE$V" Name="GullyType" Description="Identifies the predefined types of gully from which the type required may be set." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i1304" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="HalogenProof_2Vyfs0qSSHuO00025QrE$V" GlobalId="2Vyfs0qSSHuO00025QrE$V" Name="HalogenProof" Description="Produces small amount of smoke and irritating Deaerator/Gas." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HalogenProof_311xu0qSWHuO00025QrE$V" GlobalId="311xu0qSWHuO00025QrE$V" Name="HalogenProof" Description="Produces small amount of smoke and irritating Deaerator/Gas." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HandicapAccessible_0Ct5Q0qWqHuO00025QrE$V" GlobalId="0Ct5Q0qWqHuO00025QrE$V" Name="HandicapAccessible" Description="Indication that this object is designed to be accessible by the handicapped. Set to (TRUE) if this object is rated as handicap accessible according to the local building codes, otherwise (FALSE). It is giving according to the requirements of the national building code." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HandicapAccessible_0KcVm0qWaHuO00025QrE$V" GlobalId="0KcVm0qWaHuO00025QrE$V" Name="HandicapAccessible" Description="Indication that this object is designed to be accessible by the handicapped. Set to (TRUE) if this object is rated as handicap accessible according to the local building codes, otherwise (FALSE). It is giving according to the requirements of the national building code." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HandicapAccessible_1HRUy0qXaHuO00025QrE$V" GlobalId="1HRUy0qXaHuO00025QrE$V" Name="HandicapAccessible" Description="Indication that this object is designed to be accessible by the handicapped. Set to (TRUE) if this object is rated as handicap accessible according to the local building codes, otherwise (FALSE). It is giving according to the requirements of the national building code." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HandicapAccessible_1sa3o0qTmHuO00025QrE$V" GlobalId="1sa3o0qTmHuO00025QrE$V" Name="HandicapAccessible" Description="Indication that this object is designed to be accessible by the handicapped. Set to (TRUE) if this object is rated as handicap accessible according to the local building codes, otherwise (FALSE). It is giving according to the requirements of the national building code." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HandicapAccessible_1Wu3w0qVyHuO00025QrE$V" GlobalId="1Wu3w0qVyHuO00025QrE$V" Name="HandicapAccessible" Description="Indication that this object is designed to be accessible by the handicapped. Set to (TRUE) if this object is rated as handicap accessible according to the local building codes, otherwise (FALSE). It is giving according to the requirements of the national building code." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HandSignallingProhibited_2MtpmLU05CZvLEmhti1SE7" GlobalId="2MtpmLU05CZvLEmhti1SE7" Name="HandSignallingProhibited" Description="Indicates if hand signalling is prohibited in case of any failure." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HangingHeight_20VsC0qWyHuO00025QrE$V" GlobalId="20VsC0qWyHuO00025QrE$V" Name="HangingHeight" Description="The hanging height of the worksurface." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="HardeningModule_3aaI_0qUqHuO00025QrE$V" GlobalId="3aaI_0qUqHuO00025QrE$V" Name="HardeningModule" Description="A measure of the hardening module of the material (slope of stress versus strain curve after yield range)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcModulusOfElasticityMeasure" />
				<IfcSimplePropertyTemplate id="Hardness_0dKmU0qUuHuO00025QrE$V" GlobalId="0dKmU0qUuHuO00025QrE$V" Name="Hardness" Description="Water hardness as positive, multivalent ion concentration in the water (usually concentrations of calcium and magnesium ions in terms of calcium carbonate)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcIonConcentrationMeasure" />
				<IfcSimplePropertyTemplate id="Hardness_0NzH_YWI19COOLq3fLYBdn" GlobalId="0NzH_YWI19COOLq3fLYBdn" Name="Hardness" Description="Calclated Hardness from Torque and Thrust." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="HasAntiStaticSurface_1eF2E0qT0HuO00025QrE$V" GlobalId="1eF2E0qT0HuO00025QrE$V" Name="HasAntiStaticSurface" Description="Indication whether the surface finish is designed to prevent electrostatic charge (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasBallastTrack_3GWQlZqZbCOhyZObZZzqs$" GlobalId="3GWQlZqZbCOhyZObZZzqs$" Name="HasBallastTrack" Description="Indicates whether the track has ballast or not." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasBreakLineLock_1iKdHvSGX0pxudZvZ2KLk8" GlobalId="1iKdHvSGX0pxudZvZ2KLk8" Name="HasBreakLineLock" Description="Indicates whether the equipment has the function of brake line lock or not." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasBuiltInAlarm_1eLnO0qWOHuO00025QrE$V" GlobalId="1eLnO0qWOHuO00025QrE$V" Name="HasBuiltInAlarm" Description="Indicates whether the smoke sensor is included as an element within a smoke alarm/sensor unit (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasCaps_1g4E60qUOHuO00025QrE$V" GlobalId="1g4E60qUOHuO00025QrE$V" Name="HasCaps" Description="Does the inlet connection have protective caps." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasCoating_03LUq0qXCHuO00025QrE$V" GlobalId="03LUq0qXCHuO00025QrE$V" Name="HasCoating" Description="TRUE if the fin has a coating, FALSE if it does not." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasConductorRailGuardBoard_3mwIKc7vTChu5cFjTlAuyB" GlobalId="3mwIKc7vTChu5cFjTlAuyB" Name="HasConductorRailGuardBoard" Description="Indicates if a guard board is provided." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasConnector_2Bkoo$GzT9FxN8$7msTZGo" GlobalId="2Bkoo$GzT9FxN8$7msTZGo" Name="HasConnector" Description="Indicate whether the wire pair end point is terminated with a connector or not." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasCover_2Ph$60qSOHuO00025QrE$V" GlobalId="2Ph$60qSOHuO00025QrE$V" Name="HasCover" Description="Indication of whether the cable tray has a cover (=TRUE) or not (= FALSE). By default, this value should be set to FALSE.." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasCWR_1mrqmXkov0pfRjK0zoCDrB" GlobalId="1mrqmXkov0pfRjK0zoCDrB" Name="HasCWR" Description="Indicates if the track has continuous welded rails." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasDeflector_1J7hy0qUSHuO00025QrE$V" GlobalId="1J7hy0qUSHuO00025QrE$V" Name="HasDeflector" Description="Indication of whether the sprinkler has a deflector (baffle) fitted to diffuse the discharge on activation (= TRUE) or not (= FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasDefrost_2tUbW0qS0HuO00025QrE$V" GlobalId="2tUbW0qS0HuO00025QrE$V" Name="HasDefrost" Description="has the heat exchanger has defrost function or not." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasDrainage_30Z3LZrU15p9CBV6oSf4at" GlobalId="30Z3LZrU15p9CBV6oSf4at" Name="HasDrainage" Description="Indicates whether the infrastructure element has drainage embedded or not." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasDrive_2gQs80qTmHuO00025QrE$V" GlobalId="2gQs80qTmHuO00025QrE$V" Name="HasDrive" Description="Indication whether this object has an automatic drive to operate it (TRUE) or no drive (FALSE)" TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasDrive_3og7M0qXWHuO00025QrE$V" GlobalId="3og7M0qXWHuO00025QrE$V" Name="HasDrive" Description="Indication whether this object has an automatic drive to operate it (TRUE) or no drive (FALSE)" TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasEarthquakeAlarm_0i3RXtiWP9gu0kcIEX$cps" GlobalId="0i3RXtiWP9gu0kcIEX$cps" Name="HasEarthquakeAlarm" Description="Indicates whether the on-site control unit includes earthquake alarm function." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasEarthquakeCollection_2qgOIv5sT2oOCmdiwvsqux" GlobalId="2qgOIv5sT2oOCmdiwvsqux" Name="HasEarthquakeCollection" Description="Indicates whether the on-site control unit collects earthquake information." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasExteriorInsulation_0NV$S0qTyHuO00025QrE$V" GlobalId="0NV$S0qTyHuO00025QrE$V" Name="HasExteriorInsulation" Description="TRUE if the silencer has exterior insulation. FALSE if it does not." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasFan_3JVFe0qRuHuO00025QrE$V" GlobalId="3JVFe0qRuHuO00025QrE$V" Name="HasFan" Description="Terminal box has a fan inside (fan powered box)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasForeignObjectCollection_03AHgrStD9A9uC$wqdCY0t" GlobalId="03AHgrStD9A9uC$wqdCY0t" Name="HasForeignObjectCollection" Description="Indicates whether the on-site control unit collects foreign object information." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasGrabHandles_0NHIC0qW8HuO00025QrE$V" GlobalId="0NHIC0qW8HuO00025QrE$V" Name="HasGrabHandles" Description="Indicates whether the bath is fitted with handles that provide assistance to a bather in entering or leaving the bath." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasHoseUnion_06KTq0qXKHuO00025QrE$V" GlobalId="06KTq0qXKHuO00025QrE$V" Name="HasHoseUnion" Description="Indicates whether the object is fitted with a hose union connection (= TRUE) or not (= FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasHoseUnion_2Ms_s0qXGHuO00025QrE$V" GlobalId="2Ms_s0qXGHuO00025QrE$V" Name="HasHoseUnion" Description="Indicates whether the object is fitted with a hose union connection (= TRUE) or not (= FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasHotGasBypass_1mtYi0qSiHuO00025QrE$V" GlobalId="1mtYi0qSiHuO00025QrE$V" Name="HasHotGasBypass" Description="Whether or not hot gas bypass is provided for the compressor. TRUE = Yes, FALSE = No." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasIncreasingStation_34FH6g00XEcAJrdjKZ3gOO" GlobalId="34FH6g00XEcAJrdjKZ3gOO" Name="HasIncreasingStation" Description="Inform on the increasing or decreasing progress of stationing values, for referents nested in a given alignment.

If present and true, or if not present, then the relevant subsequently nested referents are expected to have greater Pset_Stationing.Station values (i.e., increasing stations).

If present and false, then the relevant subsequently nested referents are expected to have lower Pset_Stationing.Station values (i.e., decreasing stations)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasIntegralControl_0bSa_0qS0HuO00025QrE$V" GlobalId="0bSa_0qS0HuO00025QrE$V" Name="HasIntegralControl" Description="If TRUE, a self powered temperature control is included in the AirTerminal." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasIntegralShutOffDevice_3o3U00qXGHuO00025QrE$V" GlobalId="3o3U00qXGHuO00025QrE$V" Name="HasIntegralShutOffDevice" Description="Indication of whether the flushing valve has an integral shut off device fitted (set TRUE) or not (set FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasLadder_2jCtg0qWyHuO00025QrE$V" GlobalId="2jCtg0qWyHuO00025QrE$V" Name="HasLadder" Description="Indication of whether the tank is provided with a ladder (set TRUE) for access to the top. If no ladder is provided then value is set FALSE.

Note: No indication is given of the type of ladder (gooseneck etc.)" TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasLiner_0qP$g0qTuHuO00025QrE$V" GlobalId="0qP$g0qTuHuO00025QrE$V" Name="HasLiner" Description="TRUE if the fitting has interior duct insulating lining, FALSE if it does not." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasLiner_3cKlS0qTqHuO00025QrE$V" GlobalId="3cKlS0qTqHuO00025QrE$V" Name="HasLiner" Description="TRUE if the fitting has interior duct insulating lining, FALSE if it does not." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasLock_3DOZe0qWqHuO00025QrE$V" GlobalId="3DOZe0qWqHuO00025QrE$V" Name="HasLock" Description="Indication of whether a switching device has a key operated lock (=TRUE) or not (= FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasLockInside_1vFkVHKPjAvvxUxFl0WWv7" GlobalId="1vFkVHKPjAvvxUxFl0WWv7" Name="HasLockInside" Description="Indicates whether the locking is inside (TRUE) or outside (FALSE) of the point machine." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasNonSkidSurface_0fU8w0qWqHuO00025QrE$V" GlobalId="0fU8w0qWqHuO00025QrE$V" Name="HasNonSkidSurface" Description="Indication whether the surface finish is designed to prevent slippery (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasNonSkidSurface_1cFOa0qVyHuO00025QrE$V" GlobalId="1cFOa0qVyHuO00025QrE$V" Name="HasNonSkidSurface" Description="Indication whether the surface finish is designed to prevent slippery (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasNonSkidSurface_1Ytja0qT0HuO00025QrE$V" GlobalId="1Ytja0qT0HuO00025QrE$V" Name="HasNonSkidSurface" Description="Indication whether the surface finish is designed to prevent slippery (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasOpening_13ism0qWyHuO00025QrE$V" GlobalId="13ism0qWyHuO00025QrE$V" Name="HasOpening" Description="indicates whether the panel has an opening (= TRUE) or not (= FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasOutputFunction_25A5PIA$n5iuwbGGAHxZMC" GlobalId="25A5PIA$n5iuwbGGAHxZMC" Name="HasOutputFunction" Description="Indicates whether the on-site control unit includes an output function." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasPartWinding_0R57s0qU4HuO00025QrE$V" GlobalId="0R57s0qU4HuO00025QrE$V" Name="HasPartWinding" Description="Indication of whether the motor is single speed, i.e. has a single winding (= FALSE) or multi-speed i.e.has part winding (= TRUE) ." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasProtectiveEarth_1Gk6S0qTyHuO00025QrE$V" GlobalId="1Gk6S0qTyHuO00025QrE$V" Name="HasProtectiveEarth" Description="Indicates whether the object has a protective earth connection (=TRUE) or not (= FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasProtectiveEarth_1P1AW0qSSHuO00025QrE$V" GlobalId="1P1AW0qSSHuO00025QrE$V" Name="HasProtectiveEarth" Description="Indicates whether the object has a protective earth connection (=TRUE) or not (= FALSE).

One core has protective earth marked insulation, Yellow/Green." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasRainCollection_1uNBZEuvj1U9OHpOMzUZZd" GlobalId="1uNBZEuvj1U9OHpOMzUZZd" Name="HasRainCollection" Description="Indicates whether the on-site control unit collects information on rain." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasReturnAir_3DXna0qRuHuO00025QrE$V" GlobalId="3DXna0qRuHuO00025QrE$V" Name="HasReturnAir" Description="Terminal box has return air mixed with supply air from duct work." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasSillExternal_3ZmSC0qXWHuO00025QrE$V" GlobalId="3ZmSC0qXWHuO00025QrE$V" Name="HasSillExternal" Description="Indication whether the window opening has an external sill (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasSillInternal_3gwD40qXWHuO00025QrE$V" GlobalId="3gwD40qXWHuO00025QrE$V" Name="HasSillInternal" Description="Indication whether the window opening has an internal sill (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasSnowCollection_32JgEUdsb4S9ibZdwzo4JR" GlobalId="32JgEUdsb4S9ibZdwzo4JR" Name="HasSnowCollection" Description="Indicates whether the on-site control unit collects information on snow depth." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasSoundAttenuation_1udD00qSaHuO00025QrE$V" GlobalId="1udD00qSaHuO00025QrE$V" Name="HasSoundAttenuation" Description="TRUE if the coil has sound attenuation, FALSE if it does not." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasSoundAttenuator_0vjao0qS0HuO00025QrE$V" GlobalId="0vjao0qS0HuO00025QrE$V" Name="HasSoundAttenuator" Description="If TRUE, the object has sound attenuation." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasSoundAttenuator_38ASw0qRuHuO00025QrE$V" GlobalId="38ASw0qRuHuO00025QrE$V" Name="HasSoundAttenuator" Description="If TRUE, the object has sound attenuation." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasSpecialEquipment_1NpljvUif4jvHuguLm4wK5" GlobalId="1NpljvUif4jvHuguLm4wK5" Name="HasSpecialEquipment" Description="Indicates whether the sleeper has any special equipment for fastening components (e.g. Balise, signum magnet) or not." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasSteps_0ONrk0qTGHuO00025QrE$V" GlobalId="0ONrk0qTGHuO00025QrE$V" Name="HasSteps" Description="Indicates whether the chamber has steps (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasStrainer_2L4oc0qXOHuO00025QrE$V" GlobalId="2L4oc0qXOHuO00025QrE$V" Name="HasStrainer" Description="Indicates whether the gully trap has a strainer (= TRUE) or not (= FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasStrainer_3LltA0qXSHuO00025QrE$V" GlobalId="3LltA0qXSHuO00025QrE$V" Name="HasStrainer" Description="Indicates whether the gully trap has a strainer (= TRUE) or not (= FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasThermalInsulation_0$4vS0qS0HuO00025QrE$V" GlobalId="0$4vS0qS0HuO00025QrE$V" Name="HasThermalInsulation" Description="If TRUE, the air terminal has thermal insulation." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasTightJacket_1aoZzRJGjFAuxNIGdeSy5m" GlobalId="1aoZzRJGjFAuxNIGdeSy5m" Name="HasTightJacket" Description="Indicates whether the fiber has a tight jacket or not." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasTray_0Lo2g0qWCHuO00025QrE$V" GlobalId="0Lo2g0qWCHuO00025QrE$V" Name="HasTray" Description="Indicates whether the shower has a separate receptacle that catches the water in a shower and directs it to a waste outlet." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasTurbulator_2ur720qX8HuO00025QrE$V" GlobalId="2ur720qX8HuO00025QrE$V" Name="HasTurbulator" Description="TRUE if the tube has a turbulator, FALSE if it does not." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasVisualIndicator_2pmV80qWyHuO00025QrE$V" GlobalId="2pmV80qWyHuO00025QrE$V" Name="HasVisualIndicator" Description="Indication of whether the tank is provided with a visual indicator (set TRUE) that shows the water level in the tank. If no visual indicator is provided then value is set FALSE." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HasWindCollection_1NbgJQZBv91wp1sKWotMbx" GlobalId="1NbgJQZBv91wp1sKWotMbx" Name="HasWindCollection" Description="Indicates whether the on-site control unit collects information on wind." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="HazardLevel_0PFY59vVb2TvMgPikQVr$X" GlobalId="0PFY59vVb2TvMgPikQVr$X" Name="HazardLevel" Description="The hazard level (red-blue-yellow = high-medium-low or just red and yellow) is a function of likelihood and intensity and represents the degree of threat/hazard to humans, animals and material assets posed by a certain hazard type." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="HazardousWaste_0FTOQ0qU8HuO00025QrE$V" GlobalId="0FTOQ0qU8HuO00025QrE$V" Name="HazardousWaste" Description="Quantity of hazardous waste generated." TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassMeasure" />
				<IfcSimplePropertyTemplate id="HazardousWastePerUnit_2v24W0qU4HuO00025QrE$V" GlobalId="2v24W0qU4HuO00025QrE$V" Name="HazardousWastePerUnit" Description="Quantity of hazardous waste generated" TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassMeasure" />
				<IfcSimplePropertyTemplate id="HazardType_0GcxsviM9DV8_rT2wHb7ew" GlobalId="0GcxsviM9DV8_rT2wHb7ew" Name="HazardType" Description="A generic classification and a specific classification of the type of hazard." TemplateType="p_singlevalue" PrimaryMeasureType="IfcURIReference" />
				<IfcSimplePropertyTemplate id="HCO3_1Ov1VDlGf0wwH8$gwlFai2" GlobalId="1Ov1VDlGf0wwH8$gwlFai2" Name="HCO3-" Description="Content of HCO3- in the water sample." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="Headroom_25F1i0qVyHuO00025QrE$V" GlobalId="25F1i0qVyHuO00025QrE$V" Name="Headroom" Description="Actual headroom clearance for the passageway according to the current design.
The shape information is provided in addition to the shape representation and the geometric parameters used within. In cases of inconsistency between the geometric parameters and the shape properties, provided in the attached property, the geometric parameters take precedence." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="Headroom_2BqOy0qWqHuO00025QrE$V" GlobalId="2BqOy0qWqHuO00025QrE$V" Name="Headroom" Description="Actual headroom clearance for the passageway according to the current design.
The shape information is provided in addition to the shape representation and the geometric parameters used within. In cases of inconsistency between the geometric parameters and the shape properties, provided in the attached property, the geometric parameters take precedence." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="HeadShape_3$6DW0qV0HuO00025QrE$V" GlobalId="3$6DW0qV0HuO00025QrE$V" Name="HeadShape" Description="Shape of the bolt&apos;s head, e.g. &apos;Hexagon&apos;, &apos;Countersunk&apos;, &apos;Cheese&apos;" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="Heat_3knYI0qXCHuO00025QrE$V" GlobalId="3knYI0qXCHuO00025QrE$V" Name="Heat" Description="The amount of heat energy consumed during the period specified in the time series." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcEnergyMeasure" />
				<IfcSimplePropertyTemplate id="HeatDissipation_0lf5nUXkv7RfqST9JcFatz" GlobalId="0lf5nUXkv7RfqST9JcFatz" Name="HeatDissipation" Description="Indicates the heat dissipation of the electric device measured in power." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="HeatExchangeArea_2Jo0c0qU8HuO00025QrE$V" GlobalId="2Jo0c0qU8HuO00025QrE$V" Name="HeatExchangeArea" Description="Heat exchange area." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAreaMeasure" />
				<IfcSimplePropertyTemplate id="HeatExchangeSurfaceArea_0Gchc0qSeHuO00025QrE$V" GlobalId="0Gchc0qSeHuO00025QrE$V" Name="HeatExchangeSurfaceArea" Description="Heat exchange surface area associated with U-value." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAreaMeasure" />
				<IfcSimplePropertyTemplate id="HeatingAirFlowRate_0hZXs0qWmHuO00025QrE$V" GlobalId="0hZXs0qWmHuO00025QrE$V" Name="HeatingAirFlowRate" Description="Heating air flow rate in the space." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="HeatingCapacity_22IoM0qXCHuO00025QrE$V" GlobalId="22IoM0qXCHuO00025QrE$V" Name="HeatingCapacity" Description="Heating capacity." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="HeatingDesignAirFlow_0VxYS0qWiHuO00025QrE$V" GlobalId="0VxYS0qWiHuO00025QrE$V" Name="HeatingDesignAirFlow" Description="The air flowrate required during the peak heating conditions, but could also be determined by minimum ventilation requirement or minimum air change requirements." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="HeatingDesignDay_3_pGo0qV4HuO00025QrE$V" GlobalId="3_pGo0qV4HuO00025QrE$V" Name="HeatingDesignDay" Description="The month, day and time that has been selected for the heating design calculations." TemplateType="p_singlevalue" PrimaryMeasureType="IfcDateTime" />
				<IfcSimplePropertyTemplate id="HeatingDryBulb_0iNnvmWFL0rwEbwP88DOoa" GlobalId="0iNnvmWFL0rwEbwP88DOoa" Name="HeatingDryBulb" Description="Dry bulb temperature for heating design." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="HeatingDryBulb_13iMq0qWiHuO00025QrE$V" GlobalId="13iMq0qWiHuO00025QrE$V" Name="HeatingDryBulb" Description="Inside dry bulb temperature for heating design." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="HeatingDryBulb_3ouKg0qV4HuO00025QrE$V" GlobalId="3ouKg0qV4HuO00025QrE$V" Name="HeatingDryBulb" Description="Dry bulb temperature for heating design.

At outside." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="HeatingEfficiency_28GGQ0qXCHuO00025QrE$V" GlobalId="28GGQ0qXCHuO00025QrE$V" Name="HeatingEfficiency" Description="Heating efficiency under full load heating conditions." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="HeatingRelativeHumidity_193hU0qWiHuO00025QrE$V" GlobalId="193hU0qWiHuO00025QrE$V" Name="HeatingRelativeHumidity" Description="Inside relative humidity for heating design." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="HeatingTemperatureDelta_0zuMg0qRuHuO00025QrE$V" GlobalId="0zuMg0qRuHuO00025QrE$V" Name="HeatingTemperatureDelta" Description="Heating temperature difference for calculating space air flow rates." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="HeatingWaterFlowRate_19F980qSuHuO00025QrE$V" GlobalId="19F980qSuHuO00025QrE$V" Name="HeatingWaterFlowRate" Description="Water flow rate for heating." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="HeatingWetBulb_3urok0qV4HuO00025QrE$V" GlobalId="3urok0qV4HuO00025QrE$V" Name="HeatingWetBulb" Description="Outside wet bulb temperature for heating design." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="HeatOutput_3aoGK0qSGHuO00025QrE$V" GlobalId="3aoGK0qSGHuO00025QrE$V" Name="HeatOutput" Description="Total nominal heat output as listed by the Boiler manufacturer.

For water boilers, it is a function of inlet versus outlet temperature. For steam boilers, it is a function of inlet temperature versus steam pressure.  Note: as two variables are used, DefiningValues and DefinedValues are null, and values are stored in IfcTable in the following order: InletTemperature(IfcThermodynamicTemperatureMeasure), OutletTemperature(IfcThermodynamicTemperatureMeasure), HeatOutput(IfcEnergyMeasure).  The IfcTable is related to IfcPropertyTableValue using IfcMetric and IfcResourceConstraintRelationship." TemplateType="p_tablevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" SecondaryMeasureType="IfcEnergyMeasure" />
				<IfcSimplePropertyTemplate id="HeatOutput_3Ivs80qSGHuO00025QrE$V" GlobalId="3Ivs80qSGHuO00025QrE$V" Name="HeatOutput" Description="Total nominal heat output as listed by the Boiler manufacturer.

For steam boilers, it is a function of inlet temperature versus steam pressure.  Note: as two variables are used, DefiningValues and DefinedValues are null, and values are stored in IfcTable in the following order: InletTemperature(IfcThermodynamicTemperatureMeasure) and OutletTemperature(IfcThermodynamicTemperatureMeasure) in DefiningValues, and HeatOutput(IfcEnergyMeasure) in DefinedValues. For example, DefiningValues(InletTemp, OutletTemp), DefinedValues(null, HeatOutput). The IfcTable is related to IfcPropertyTableValue using IfcMetric and IfcResourceConstraintRelationship." TemplateType="p_tablevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" SecondaryMeasureType="IfcEnergyMeasure" />
				<IfcSimplePropertyTemplate id="HeatOutputRate_31T7a0qWaHuO00025QrE$V" GlobalId="31T7a0qWaHuO00025QrE$V" Name="HeatOutputRate" Description="Overall heat transfer rate." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="HeatRejectionRate_1VuUc0qSmHuO00025QrE$V" GlobalId="1VuUc0qSmHuO00025QrE$V" Name="HeatRejectionRate" Description="Sum of the refrigeration effect and the heat equivalent of the power input to the compressor." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="HeatRejectionRate_3ECQQ0qU8HuO00025QrE$V" GlobalId="3ECQQ0qU8HuO00025QrE$V" Name="HeatRejectionRate" Description="Sum of the refrigeration effect and the heat equivalent of the power input to the compressor." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="HeatTransferCoefficient_1DjNg0qSyHuO00025QrE$V" GlobalId="1DjNg0qSyHuO00025QrE$V" Name="HeatTransferCoefficient" Description="Heat transfer coefficient-area product." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" />
				<IfcSimplePropertyTemplate id="HeatTransferDimension_07oTW0qWeHuO00025QrE$V" GlobalId="07oTW0qWeHuO00025QrE$V" Name="HeatTransferDimension" Description="Indicates how heat is transmitted according to the shape of the space heater." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_SpaceHeaterHeatTransferDimension">
						<EnumerationValues>
							<IfcLabel-wrapper>POINT</IfcLabel-wrapper>
							<IfcLabel-wrapper>PATH</IfcLabel-wrapper>
							<IfcLabel-wrapper>SURFACE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="HeatTransferMedium_0KviS0qWeHuO00025QrE$V" GlobalId="0KviS0qWeHuO00025QrE$V" Name="HeatTransferMedium" Description="Enumeration defining the heat transfer medium if applicable." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_HeatTransferMedium">
						<EnumerationValues>
							<IfcLabel-wrapper>WATER</IfcLabel-wrapper>
							<IfcLabel-wrapper>STEAM</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="HeatTransferSurfaceArea_24qbw0qSGHuO00025QrE$V" GlobalId="24qbw0qSGHuO00025QrE$V" Name="HeatTransferSurfaceArea" Description="Total heat transfer area of the vessel." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAreaMeasure" />
				<IfcSimplePropertyTemplate id="HeatTransferTypeEnum_2eawM0qS0HuO00025QrE$V" GlobalId="2eawM0qS0HuO00025QrE$V" Name="HeatTransferTypeEnum" Description="Type of heat transfer between the two air streams." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_AirToAirHeatTransferHeatTransferType">
						<EnumerationValues>
							<IfcLabel-wrapper>SENSIBLE</IfcLabel-wrapper>
							<IfcLabel-wrapper>LATENT</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="HeavyMetalsPotential_0SJ24gCS50MRli9TNYKxGx" GlobalId="0SJ24gCS50MRli9TNYKxGx" Name="HeavyMetalsPotential" Description="Description or rating of the potential presence of heavy metals in the ground." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="Height_0PMRA0qVyHuO00025QrE$V" GlobalId="0PMRA0qVyHuO00025QrE$V" Name="Height" Description="Characteristic height

It is the upper height of the railing above the floor or stair.
The size information is provided in addition to the shape representation and the geometric parameters used within. In cases of inconsistency between the geometric parameters and the size properties, provided in the attached property set, the geometric parameters take precedence." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="Height_1bY040qSKHuO00025QrE$V" GlobalId="1bY040qSKHuO00025QrE$V" Name="Height" Description="The requested height (vertical extension in elevation) of the provision for void&quot;, only provided if the Shape property is set to &quot;rectangle&quot;." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="Height_3fjAM0qX8HuO00025QrE$V" GlobalId="3fjAM0qX8HuO00025QrE$V" Name="Height" Description="Characteristic height

Length of the fin as measured perpendicular to the direction of airflow." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="Height_3leRmD4gzEdRgnDuLoYX91" GlobalId="3leRmD4gzEdRgnDuLoYX91" Name="Height" Description="Characteristic height

Vertical extension in elevation. Only provided if the Shape property is set to &quot;rectangle&quot;." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="HeightAboveMainDeck_1nG3Ga$fP8IAo6dBpx7fCk" GlobalId="1nG3Ga$fP8IAo6dBpx7fCk" Name="HeightAboveMainDeck" Description="Height of the fairlead above the main deck of the vessel" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="HgContent_1F_XTqiBD9dQNNlCtXJFbZ" GlobalId="1F_XTqiBD9dQNNlCtXJFbZ" Name="HgContent" Description="Content of Mercury. The unit must be defined in _&apos;IfcPropertySingleValue_._Unit&apos;_." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="HigherHeatingValue_1EzQ00qUqHuO00025QrE$V" GlobalId="1EzQ00qUqHuO00025QrE$V" Name="HigherHeatingValue" Description="Higher Heating Value is defined as the amount of energy released (MJ/kg) when a fuel is burned completely, and H2O is in liquid form in the combustion products." TemplateType="p_singlevalue" PrimaryMeasureType="IfcHeatingValueMeasure" />
				<IfcSimplePropertyTemplate id="HighestSeatingHeight_3Gbly0qUWHuO00025QrE$V" GlobalId="3Gbly0qUWHuO00025QrE$V" Name="HighestSeatingHeight" Description="The value of seating height of high level if the chair height is adjustable." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="HighWaterLevel_0S3mSsoqT9xvSAc$Cv67oe" GlobalId="0S3mSsoqT9xvSAc$Cv67oe" Name="HighWaterLevel" Description="High water level" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="HinderingObstaclesDescription_2$H1tVSRb5I9MS8oseNlm7" GlobalId="2$H1tVSRb5I9MS8oseNlm7" Name="HinderingObstaclesDescription" Description="Description of obstacles that hinder the visibility for the staff in the station." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="HoleDiameter_2CRBoJG6P9xwWyupBQZ76M" GlobalId="2CRBoJG6P9xwWyupBQZ76M" Name="HoleDiameter" Description="Drilled Borehole diameter. Also referred to as &quot;Caliper&quot;, continuous measurement of the as-drilled diameter inside the borehole." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="HoleDiameter_2GN$WQ6b1BpetO1RE7phA4" GlobalId="2GN$WQ6b1BpetO1RE7phA4" Name="HoleDiameter" Description="The diameter of the bolt hole." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="HoleLength_29Zk0kSL57MQM5XAzKvCEW" GlobalId="29Zk0kSL57MQM5XAzKvCEW" Name="HoleLength" Description="The length of the bolt hole." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="HollowCorePlugging_3mD2I0qVGHuO00025QrE$V" GlobalId="3mD2I0qVGHuO00025QrE$V" Name="HollowCorePlugging" Description="A descriptive label for how the hollow core ends are treated: they may be left open, closed with a plug, or sealed with cast concrete. Values would be, for example: &apos;Unplugged&apos;, &apos;Plugged&apos;, &apos;SealedWithConcrete&apos;. This property applies to hollow core slabs only." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="HollowSleeperUsage_24bWI7gefEm81rwgNZrJim" GlobalId="24bWI7gefEm81rwgNZrJim" Name="HollowSleeperUsage" Description="Indicates the purpose of using hollow sleeper. The possible value can be eg. cable trenching, protection of turnout mechanism, etc." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="HoopBarPitch_01DcC0qW0HuO00025QrE$V" GlobalId="01DcC0qW0HuO00025QrE$V" Name="HoopBarPitch" Description="The pitch length of the hoop bar." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="HorizontalBarPitch_3UM7w0qW0HuO00025QrE$V" GlobalId="3UM7w0qW0HuO00025QrE$V" Name="HorizontalBarPitch" Description="The pitch length of the horizontal bar." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="HorizontalFlatness_0J7SvVYBP1bw$w1Fbxtnea" GlobalId="0J7SvVYBP1bw$w1Fbxtnea" Name="HorizontalFlatness" Description="Indicative (95%-100%) range flatness associated to the horizontal surface in XY, if different to the overall flatness." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="HorizontalOrthogonality_1XAcvVmsb509eDuyDemhcT" GlobalId="1XAcvVmsb509eDuyDemhcT" Name="HorizontalOrthogonality" Description="Indicative (95%-100%) range orthogonality associated to the horizontal shape and orientation in X, if different to the overall orthogonality." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="HorizontalSpacing_1UHNsaYer7lfpt1uCNQwnz" GlobalId="1UHNsaYer7lfpt1uCNQwnz" Name="HorizontalSpacing" Description="Horizontal spacing of bolts." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="HorizontalSpacing_2dYsG0qX8HuO00025QrE$V" GlobalId="2dYsG0qX8HuO00025QrE$V" Name="HorizontalSpacing" Description="Horizontal spacing between tubes in the tube bundle." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="HorizontalStraightness_0wr5muKv1DqPs2T8tTtcFR" GlobalId="0wr5muKv1DqPs2T8tTtcFR" Name="HorizontalStraightness" Description="Indicative (95%-100%) range straightness associated to the horizontal shape in X, if different to the overall straightness." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="HorizontalTolerance_3$ft4Ga9X6DxvQZ768Kj3w" GlobalId="3$ft4Ga9X6DxvQZ768Kj3w" Name="HorizontalTolerance" Description="Indicative (95%-100%) range tolerance associated to the horizontal shape and position in X, if different to the overall tolerance." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="HorizontalUncertainty_1QRo9gJgj5XxCUOkwGIQ2K" GlobalId="1QRo9gJgj5XxCUOkwGIQ2K" Name="HorizontalUncertainty" Description="Indicative (95%-100%) range diameter associated to the vertical shape and position in X, if different to the linear uncertainty." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="HoseConnectionSize_2VjSg0qUOHuO00025QrE$V" GlobalId="2VjSg0qUOHuO00025QrE$V" Name="HoseConnectionSize" Description="The size of connections to which a hose may be connected (other than that to be linked to a pumping unit)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="HoseDiameter_3k_$i0qUOHuO00025QrE$V" GlobalId="3k_$i0qUOHuO00025QrE$V" Name="HoseDiameter" Description="Notional diameter (bore) of the hose." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="HoseLength_3rYdA0qUOHuO00025QrE$V" GlobalId="3rYdA0qUOHuO00025QrE$V" Name="HoseLength" Description="Notional length of the hose fitted to the hose reel when fully extended." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="HoseNozzleType_3y6Ee0qUOHuO00025QrE$V" GlobalId="3y6Ee0qUOHuO00025QrE$V" Name="HoseNozzleType" Description="Identifies the predefined types of nozzle (in terms of spray pattern) fitted to the end of the hose from which the type required may be set." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_HoseNozzleType">
						<EnumerationValues>
							<IfcLabel-wrapper>FOG</IfcLabel-wrapper>
							<IfcLabel-wrapper>STRAIGHTSTREAM</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="HoseReelMountingType_3PXj40qUOHuO00025QrE$V" GlobalId="3PXj40qUOHuO00025QrE$V" Name="HoseReelMountingType" Description="Identifies the predefined types of hose reel mounting from which the type required may be set." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_HoseReelMountingType">
						<EnumerationValues>
							<IfcLabel-wrapper>CABINET_RECESSED</IfcLabel-wrapper>
							<IfcLabel-wrapper>CABINET_SEMIRECESSED</IfcLabel-wrapper>
							<IfcLabel-wrapper>SURFACE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="HoseReelType_3CQU80qUOHuO00025QrE$V" GlobalId="3CQU80qUOHuO00025QrE$V" Name="HoseReelType" Description="Identifies the predefined types of hose arrangement from which the type required may be set." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_HoseReelType">
						<EnumerationValues>
							<IfcLabel-wrapper>RACK</IfcLabel-wrapper>
							<IfcLabel-wrapper>REEL</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="HotStripOrientation_3feSaKbt1E2xMLDm8EVzJQ" GlobalId="3feSaKbt1E2xMLDm8EVzJQ" Name="HotStripOrientation" Description="Position of the hot strip, which indicates the direction of the focus of the light beam and is given in terms like &quot;left upper quadrant (LUQ)&quot; or &quot;5 o&apos;clock&quot;." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="HousingThickness_3anWQ0qRuHuO00025QrE$V" GlobalId="3anWQ0qRuHuO00025QrE$V" Name="HousingThickness" Description="Air terminal box housing material thickness." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="HumidifierApplication_3AxUa0qUaHuO00025QrE$V" GlobalId="3AxUa0qUaHuO00025QrE$V" Name="HumidifierApplication" Description="Humidifier application.

Fixed: Humidifier installed in a ducted flow distribution system.
Portable: Humidifier is not installed in a ducted flow distribution system." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_HumidifierApplication">
						<EnumerationValues>
							<IfcLabel-wrapper>PORTABLE</IfcLabel-wrapper>
							<IfcLabel-wrapper>FIXED</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="HumidityEffectiveness_1lMpM0qS0HuO00025QrE$V" GlobalId="1lMpM0qS0HuO00025QrE$V" Name="HumidityEffectiveness" Description="Humidity heat transfer effectiveness: The ratio of primary airflow absolute humidity changes to maximum possible absolute humidity changes." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="HumidityMax_3k4hawTVb5Ahvmj2kU6M$L" GlobalId="3k4hawTVb5Ahvmj2kU6M$L" Name="HumidityMax" Description="Maximal permitted humidity of the space or zone that is required from user/designer view point. If no summer or winter space humidity requirements are given, it applies all year, otherwise for the intermediate period." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="HumidityMin_2FMCtdeG12eO0syuCDdRg4" GlobalId="2FMCtdeG12eO0syuCDdRg4" Name="HumidityMin" Description="Minimal permitted humidity of the space or zone that is required from user/designer view point. If no summer or winter space humidity requirements are given, it applies all year, otherwise for the intermediate period." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="HumiditySetPoint_1EvwdsIJzCchlD2WxBx7LQ" GlobalId="1EvwdsIJzCchlD2WxBx7LQ" Name="HumiditySetPoint" Description="Humidity of the space or zone that is required from user/designer view point. If no summer or winter space humidity requirements are given, it applies all year, otherwise for the intermediate period. Provide this property, if no humidity range (Min-Max) is available." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="HumiditySummer_33Q$I6qEfEqR6EBSPjSvTF" GlobalId="33Q$I6qEfEqR6EBSPjSvTF" Name="HumiditySummer" Description="Humidity of the space or zone for the hot (summer) period, that is required from user/designer view point and provided as requirement for cooling." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="HumidityWinter_2HWhTpDuvDQfU6PHZnzsch" GlobalId="2HWhTpDuvDQfU6PHZnzsch" Name="HumidityWinter" Description="Humidity of the space or zone for the cold (winter) period that is required from user/designer view point and provided as requirement for heating." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="HydraulicConductivity_0n5hy7wA9CGeRruzAkgVAG" GlobalId="0n5hy7wA9CGeRruzAkgVAG" Name="HydraulicConductivity" Description="Hydraulic Conductivity (permeability) of soil for water, given with the K or Kf value in m/s" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLinearVelocityMeasure" />
				<IfcSimplePropertyTemplate id="HydraulicConductivity_19kpZnztn1VQFucvmNUC96" GlobalId="19kpZnztn1VQFucvmNUC96" Name="HydraulicConductivity" Description="Hydraulic Conductivity (permeability) of soil for water, given with the K or Kf value in m/s." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLinearVelocityMeasure" />
				<IfcSimplePropertyTemplate id="HydraulicDiameter_3la9E0qTuHuO00025QrE$V" GlobalId="3la9E0qTuHuO00025QrE$V" Name="HydraulicDiameter" Description="Hydraulic diameter." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="HydraulicPermeability_3iagtDsw9DTgUKGeH1bJil" GlobalId="3iagtDsw9DTgUKGeH1bJil" Name="HydraulicPermeability" Description="A measurement of the ability of a fluid to flow through a rock. Represented by the variable &quot;k&quot;. The quality of the soil that enables water to move through the profile. Permeability is measured as the number of metres per sec that water moves through the saturated soil." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLinearVelocityMeasure" />
				<IfcSimplePropertyTemplate id="HydraulicPermeabilityHorizontal_0cGG3NyxfEXf7guGaaxUkx" GlobalId="0cGG3NyxfEXf7guGaaxUkx" Name="HydraulicPermeabilityHorizontal" Description="Value of horizontal permeability." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLinearVelocityMeasure" />
				<IfcSimplePropertyTemplate id="HydraulicPermeabilityVertical_1aKYiWegb7iPXpy4cjfbOY" GlobalId="1aKYiWegb7iPXpy4cjfbOY" Name="HydraulicPermeabilityVertical" Description="Value of vertical permeability." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLinearVelocityMeasure" />
				<IfcSimplePropertyTemplate id="HygrothermalRating_3iHzY0qTiHuO00025QrE$V" GlobalId="3iHzY0qTiHuO00025QrE$V" Name="HygrothermalRating" Description="Resistance against hygrothermal impact from different temperatures and humidities inside and outside. It is given according to the national code or regulation." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="I1_1LFqY0qVmHuO00025QrE$V" GlobalId="1LFqY0qVmHuO00025QrE$V" Name="I1" Description="The (thermal) lower testing current limit in [x In], indicating that for currents lower than I1, the tripping time shall be longer than the associated tripping time, T2." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="I1_3ocdo0qVmHuO00025QrE$V" GlobalId="3ocdo0qVmHuO00025QrE$V" Name="I1" Description="The (thermal) lower testing current limit in [x In], indicating that for currents lower than I1, the tripping time shall be longer than the associated tripping time, T2." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="I2_1RDIc0qVmHuO00025QrE$V" GlobalId="1RDIc0qVmHuO00025QrE$V" Name="I2" Description="The (thermal) upper testing current limit in [x In], indicating that for currents larger than I2, the tripping time shall be shorter than the associated tripping time, T2." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="I2_3ua5s0qVmHuO00025QrE$V" GlobalId="3ua5s0qVmHuO00025QrE$V" Name="I2" Description="The (thermal) upper testing current limit in [x In], indicating that for currents larger than I2, the tripping time shall be shorter than the associated tripping time, T2." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="I2TApplicability_3rIA80qViHuO00025QrE$V" GlobalId="3rIA80qViHuO00025QrE$V" Name="I2TApplicability" Description="The applicability of the time adjustment related to the tripping function." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i69" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="I4_1pfKG0qVmHuO00025QrE$V" GlobalId="1pfKG0qVmHuO00025QrE$V" Name="I4" Description="The lower electromagnetic testing current limit in [x In], indicating that for currents lower than I4, the tripping time shall be longer than the associated tripping time, T5, i.e. the device shall not trip instantaneous." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="I5_1vcoK0qVmHuO00025QrE$V" GlobalId="1vcoK0qVmHuO00025QrE$V" Name="I5" Description="The upper electromagnetic testing current limit in [x In], indicating that for currents larger than I5, the tripping time shall be shorter than or equal to the associated tripping time, T5, i.e. the device shall trip instantaneous." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="IC60269_0$onu0qVuHuO00025QrE$V" GlobalId="0$onu0qVuHuO00025QrE$V" Name="IC60269" Description="The breaking capacity in [A] for fuses in accordance with the IEC 60269 series." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="ICM60947_0QF1M0qVeHuO00025QrE$V" GlobalId="0QF1M0qVeHuO00025QrE$V" Name="ICM60947" Description="The making capacity in [A] for a circuit breaker or motor protection device tested in accordance with the IEC 60947 series." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="ICM60947_17reu0qVqHuO00025QrE$V" GlobalId="17reu0qVqHuO00025QrE$V" Name="ICM60947" Description="The making capacity in [A] for a circuit breaker or motor protection device tested in accordance with the IEC 60947 series." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="ICN60898_39nBW0qVaHuO00025QrE$V" GlobalId="39nBW0qVaHuO00025QrE$V" Name="ICN60898" Description="The nominal breaking capacity in [A] for an MCB tested in accordance with the IEC 60898 series." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="ICS60898_3IjOc0qVaHuO00025QrE$V" GlobalId="3IjOc0qVaHuO00025QrE$V" Name="ICS60898" Description="The service breaking capacity in [A] for an MCB tested in accordance with the IEC 60898 series." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="ICS60947_30q_Q0qVaHuO00025QrE$V" GlobalId="30q_Q0qVaHuO00025QrE$V" Name="ICS60947" Description="The service breaking capacity in [A] for an object tested in accordance with the IEC 60947 series." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="ICU60947_2siUW0qVaHuO00025QrE$V" GlobalId="2siUW0qVaHuO00025QrE$V" Name="ICU60947" Description="The ultimate breaking capacity in [A] for an object tested in accordance with the IEC 60947 series." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="ICW60947_0Ktii0qVeHuO00025QrE$V" GlobalId="0Ktii0qVeHuO00025QrE$V" Name="ICW60947" Description="The thermal withstand current in [A] for a circuit breaker or motor protection device tested in accordance with the IEC 60947 series. The value shall be related to 1 s." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="ICW60947_10hu00qVqHuO00025QrE$V" GlobalId="10hu00qVqHuO00025QrE$V" Name="ICW60947" Description="The thermal withstand current in [A] for a circuit breaker or motor protection device tested in accordance with the IEC 60947 series. The value shall be related to 1 s." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="IdealCapacity_1aMTA0qSiHuO00025QrE$V" GlobalId="1aMTA0qSiHuO00025QrE$V" Name="IdealCapacity" Description="Compressor capacity under ideal conditions." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="IdealShaftPower_1hWE20qSiHuO00025QrE$V" GlobalId="1hWE20qSiHuO00025QrE$V" Name="IdealShaftPower" Description="Compressor shaft power under ideal conditions." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="IfNotAccomplished_0OSLA0qVWHuO00025QrE$V" GlobalId="0OSLA0qVWHuO00025QrE$V" Name="IfNotAccomplished" Description="Comments if the job is not accomplished." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="IfNotAccomplished_1kaSO0qVSHuO00025QrE$V" GlobalId="1kaSO0qVSHuO00025QrE$V" Name="IfNotAccomplished" Description="Comments if the job is not accomplished." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="IK_Code_2kpG9_rK93LwNz4pCQcRnH" GlobalId="2kpG9_rK93LwNz4pCQcRnH" Name="IK_Code" Description="IK Code according to IEC 62262 (2002) is a numeric classification for the degree of protection provided by enclosures for electrical equipment against external mechanical impacts.
&gt; NOTE&amp;nbsp; In earlier labeling, the third numeral (1..) had been occasionally added to the closely related IP Code on ingress protection, to indicate the level of impact protection." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="Illuminance_2xCio0qWeHuO00025QrE$V" GlobalId="2xCio0qWeHuO00025QrE$V" Name="Illuminance" Description="Required average illuminance value for this space." TemplateType="p_singlevalue" PrimaryMeasureType="IfcIlluminanceMeasure" />
				<IfcSimplePropertyTemplate id="ImageResolution_1ulCcMFG1EThizMRoqB5OU" GlobalId="1ulCcMFG1EThizMRoqB5OU" Name="ImageResolution" Description="Indicates the image resolution of snow depth meter." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ImageShootingMode_05XzrlWZHBm92_8rlLkSV7" GlobalId="05XzrlWZHBm92_8rlLkSV7" Name="ImageShootingMode" Description="Indicates the type or manner of snow depth meter image shooting." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ImageShootingMode">
						<EnumerationValues>
							<IfcLabel-wrapper>AUTOMATIC</IfcLabel-wrapper>
							<IfcLabel-wrapper>MANUAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ImaginaryImpedanceRatio_2ic_E0qX4HuO00025QrE$V" GlobalId="2ic_E0qX4HuO00025QrE$V" Name="ImaginaryImpedanceRatio" Description="The ratio between the imaginary part of the zero sequence impedance and the imaginary part of the positive impedance (i.e. imaginary part of the short-circuit voltage) of the transformer.
Used for three-phase transformer which includes a N-conductor." TemplateType="p_singlevalue" PrimaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="ImpactParameter_2CaAthV3TF$xal26j2$MkZ" GlobalId="2CaAthV3TF$xal26j2$MkZ" Name="ImpactParameter" Description="Impact parameter of the equipment." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAccelerationMeasure" />
				<IfcSimplePropertyTemplate id="Impedence_37u080qSCHuO00025QrE$V" GlobalId="37u080qSCHuO00025QrE$V" Name="Impedence" Description="Indicates the speaker impedence." TemplateType="p_singlevalue" PrimaryMeasureType="IfcFrequencyMeasure" />
				<IfcSimplePropertyTemplate id="ImpellerDiameter_0ISNQ0qUGHuO00025QrE$V" GlobalId="0ISNQ0qUGHuO00025QrE$V" Name="ImpellerDiameter" Description="Diameter of object - used to scale performance of geometrically similar objects." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ImpellerDiameter_1sr0m0qSiHuO00025QrE$V" GlobalId="1sr0m0qSiHuO00025QrE$V" Name="ImpellerDiameter" Description="Diameter of object - used to scale performance of geometrically similar objects." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ImpellerDiameter_1zo480qVuHuO00025QrE$V" GlobalId="1zo480qVuHuO00025QrE$V" Name="ImpellerDiameter" Description="Diameter of object - used to scale performance of geometrically similar objects." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ImpuritiesContent_0sERe0qUuHuO00025QrE$V" GlobalId="0sERe0qUuHuO00025QrE$V" Name="ImpuritiesContent" Description="Fraction of impurities such as dust to the total amount of water. This is measured in weight of impurities per weight of water and is therefore unitless." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="IncomingStation_2ScYZDmQ9C9vR878Q0zliC" GlobalId="2ScYZDmQ9C9vR878Q0zliC" Name="IncomingStation" Description="The optional station value of the incoming segment that ends at this location. This value needs to be set if the intention is to specify a station equation, i.e. a location where stationing changes." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="IndicationRodMovementRange_2EWdqFr25C5QKm2WsoAIDD" GlobalId="2EWdqFr25C5QKm2WsoAIDD" Name="IndicationRodMovementRange" Description="Indicates the range of indication rod movement." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="IndicatorsUnit_2FJo40qU4HuO00025QrE$V" GlobalId="2FJo40qU4HuO00025QrE$V" Name="IndicatorsUnit" Description="The unit of the quantity the environmental indicators values are related with." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="IndoorEnvironment_2h9yA6q2T9ZfOglK_Wohce" GlobalId="2h9yA6q2T9ZfOglK_Wohce" Name="IndoorEnvironment" Description="Adjustment of the service life resulting from the effect of the indoor environment (where appropriate)." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="Inductance_26NOHc5AHAsRdIVv$vqQ_g" GlobalId="26NOHc5AHAsRdIVv$vqQ_g" Name="Inductance" Description="Measure of the Inductance." TemplateType="p_singlevalue" PrimaryMeasureType="IfcInductanceMeasure" />
				<IfcSimplePropertyTemplate id="InductionRatio_0zbPy0qRyHuO00025QrE$V" GlobalId="0zbPy0qRyHuO00025QrE$V" Name="InductionRatio" Description="Induction ratio versus distance from the diffuser and its discharge direction; induction ratio (or entrainment ratio) is the ratio of the volumetric flow rate in the jet to the volumetric flow rate at the air terminal." TemplateType="p_tablevalue" PrimaryMeasureType="IfcReal" SecondaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="InertWaste_0rcoQ0qU8HuO00025QrE$V" GlobalId="0rcoQ0qU8HuO00025QrE$V" Name="InertWaste" Description="Quantity of inert waste generated ." TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassMeasure" />
				<IfcSimplePropertyTemplate id="InertWastePerUnit_3Wzwk0qU4HuO00025QrE$V" GlobalId="3Wzwk0qU4HuO00025QrE$V" Name="InertWastePerUnit" Description="Quantity of inert waste generated" TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassMeasure" />
				<IfcSimplePropertyTemplate id="Infiltration_0ZjeK0qTmHuO00025QrE$V" GlobalId="0ZjeK0qTmHuO00025QrE$V" Name="Infiltration" Description="Infiltration flowrate of outside air for the filler object based on the area of the filler object at a pressure level of 50 Pascals. It shall be used, if the length of all joints is unknown." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="Infiltration_3J4Kq0qXWHuO00025QrE$V" GlobalId="3J4Kq0qXWHuO00025QrE$V" Name="Infiltration" Description="Infiltration flowrate of outside air for the filler object based on the area of the filler object at a pressure level of 50 Pascals. It shall be used, if the length of all joints is unknown." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="InfiltrationDiversitySummer_0c2UQ0qRuHuO00025QrE$V" GlobalId="0c2UQ0qRuHuO00025QrE$V" Name="InfiltrationDiversitySummer" Description="Diversity factor for Summer infiltration." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="InfiltrationDiversitySummer_3pFGu0qX0HuO00025QrE$V" GlobalId="3pFGu0qX0HuO00025QrE$V" Name="InfiltrationDiversitySummer" Description="Diversity factor for Summer infiltration." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="InfiltrationDiversityWinter_0hPp40qRuHuO00025QrE$V" GlobalId="0hPp40qRuHuO00025QrE$V" Name="InfiltrationDiversityWinter" Description="Diversity factor for Winter infiltration." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="InfiltrationDiversityWinter_3vouM0qX0HuO00025QrE$V" GlobalId="3vouM0qX0HuO00025QrE$V" Name="InfiltrationDiversityWinter" Description="Diversity factor for Winter infiltration." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="InfiltrationSensible_3EacU0qWiHuO00025QrE$V" GlobalId="3EacU0qWiHuO00025QrE$V" Name="InfiltrationSensible" Description="Heat gains and losses from infiltration." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="InfiltrationSensibleHistory_0LW5q0qWmHuO00025QrE$V" GlobalId="0LW5q0qWmHuO00025QrE$V" Name="InfiltrationSensibleHistory" Description="Heat gains and losses from infiltration." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="InflowRate_1Fbf$7xkPDquOoD4prK2TA" GlobalId="1Fbf$7xkPDquOoD4prK2TA" Name="InflowRate" Description="Measured or expected water inflow rate during observation." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="InflowSum_2OMwvg2WD9yQR5E1WntDRu" GlobalId="2OMwvg2WD9yQR5E1WntDRu" Name="InflowSum" Description="Groundwater inflow measured or expected during one hour." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumeMeasure" />
				<IfcSimplePropertyTemplate id="InformationLength_05Ecr739L7IvyGuZ7C$2zv" GlobalId="05Ecr739L7IvyGuZ7C$2zv" Name="InformationLength" Description="Indicates supported bytes of the data Information, e.g.127 bytes." TemplateType="p_singlevalue" PrimaryMeasureType="IfcInteger" />
				<IfcSimplePropertyTemplate id="InitialResistance_3I4lW0qUKHuO00025QrE$V" GlobalId="3I4lW0qUKHuO00025QrE$V" Name="InitialResistance" Description="Initial new filter fluid resistance (i.e., pressure drop at the maximum air flowrate across the filter when the filter is new per ASHRAE Standard 52.1)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="InitialTension_3L_aQ0qVGHuO00025QrE$V" GlobalId="3L_aQ0qVGHuO00025QrE$V" Name="InitialTension" Description="The initial stress of the tendon. This property applies to prestressed concrete elements only." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="InjectionDistributionEquipment_2lnxV9oFn01AvbA6wexzaD" GlobalId="2lnxV9oFn01AvbA6wexzaD" Name="InjectionDistributionEquipment" Description="Equipment used for distributing the grout." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_InjectionDistributionEquipment">
						<EnumerationValues>
							<IfcLabel-wrapper>INJECTIONHOSE</IfcLabel-wrapper>
							<IfcLabel-wrapper>INJECTIONTUBE</IfcLabel-wrapper>
							<IfcLabel-wrapper>PETROLEUMPIPE</IfcLabel-wrapper>
							<IfcLabel-wrapper>TUBESAMANCHETTE</IfcLabel-wrapper>
							<IfcLabel-wrapper>PILLOW</IfcLabel-wrapper>
							<IfcLabel-wrapper>BULLFLEX</IfcLabel-wrapper>
							<IfcLabel-wrapper>USERDEFINED</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTDEFINED</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="InjectionPackerType_3Nc5dkhQPFdAnZR5V5geX1" GlobalId="3Nc5dkhQPFdAnZR5V5geX1" Name="InjectionPackerType" Description="Equipment use to uphold pressure during injection." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_InjectionPackerType">
						<EnumerationValues>
							<IfcLabel-wrapper>SINGLE</IfcLabel-wrapper>
							<IfcLabel-wrapper>DOUBLE</IfcLabel-wrapper>
							<IfcLabel-wrapper>USERDEFINED</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTDEFINED</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="InjectionPhase_0fT68GhTX6Ou_9wM45hYLt" GlobalId="0fT68GhTX6Ou_9wM45hYLt" Name="InjectionPhase" Description="Specifies when injection is performed." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_InjectionPhase">
						<EnumerationValues>
							<IfcLabel-wrapper>PRE_INJECTION</IfcLabel-wrapper>
							<IfcLabel-wrapper>POST_INJECTION</IfcLabel-wrapper>
							<IfcLabel-wrapper>CONCURRENT_INJECTION</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="InjectionPressure_29eahe7Wr9cw6L65Rn8pJw" GlobalId="29eahe7Wr9cw6L65Rn8pJw" Name="InjectionPressure" Description="Required pressure for injection." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="InletConnectionSize_1P_m40qUeHuO00025QrE$V" GlobalId="1P_m40qUeHuO00025QrE$V" Name="InletConnectionSize" Description="Size of the inlet connection.

Note that all inlet connections are assumed to be the same size." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="InletConnectionSize_34APi0qXOHuO00025QrE$V" GlobalId="34APi0qXOHuO00025QrE$V" Name="InletConnectionSize" Description="Size of the inlet connection.
Note that all inlet connections are assumed to be the same size." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="InletConnectionSize_3f1Xe0qUOHuO00025QrE$V" GlobalId="3f1Xe0qUOHuO00025QrE$V" Name="InletConnectionSize" Description="Size of the inlet connection.
Note that all inlet connections are assumed to be the same size.

Connection to the hose reel." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="InletDiameter_1K0o40qUOHuO00025QrE$V" GlobalId="1K0o40qUOHuO00025QrE$V" Name="InletDiameter" Description="The inlet diameter of the breeching inlet." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="InletPatternType_2cN3O0qXOHuO00025QrE$V" GlobalId="2cN3O0qXOHuO00025QrE$V" Name="InletPatternType" Description="Identifies the pattern of inlet connections to a trap.

A trap may have 0,1,2,3 or 4 inlet connections and the pattern of their arrangement may vary. The enumeration makes the convention that an outlet is either vertical or is placed at the bottom (south side) of the trap (when viewed in plan). Position 1 is to the left (west), position 2 is to the top (north), position 3 is to the right (east) and position 4 is to the bottom (south)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_InletPatternType">
						<EnumerationValues>
							<IfcLabel-wrapper>NONE</IfcLabel-wrapper>
							<IfcLabel-wrapper>1</IfcLabel-wrapper>
							<IfcLabel-wrapper>2</IfcLabel-wrapper>
							<IfcLabel-wrapper>3</IfcLabel-wrapper>
							<IfcLabel-wrapper>4</IfcLabel-wrapper>
							<IfcLabel-wrapper>12</IfcLabel-wrapper>
							<IfcLabel-wrapper>13</IfcLabel-wrapper>
							<IfcLabel-wrapper>14</IfcLabel-wrapper>
							<IfcLabel-wrapper>23</IfcLabel-wrapper>
							<IfcLabel-wrapper>24</IfcLabel-wrapper>
							<IfcLabel-wrapper>34</IfcLabel-wrapper>
							<IfcLabel-wrapper>123</IfcLabel-wrapper>
							<IfcLabel-wrapper>124</IfcLabel-wrapper>
							<IfcLabel-wrapper>134</IfcLabel-wrapper>
							<IfcLabel-wrapper>234</IfcLabel-wrapper>
							<IfcLabel-wrapper>1234</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="InLineRowSpacing_1dA_O0qX8HuO00025QrE$V" GlobalId="1dA_O0qX8HuO00025QrE$V" Name="InLineRowSpacing" Description="In-line tube row spacing." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="InnerDiameter_37z$O0qVCHuO00025QrE$V" GlobalId="37z$O0qVCHuO00025QrE$V" Name="InnerDiameter" Description="The actual inner diameter of the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="InnerDiameter_3yqzmY$VrEe8Jo0Bw35LgZ" GlobalId="3yqzmY$VrEe8Jo0Bw35LgZ" Name="InnerDiameter" Description="The actual inner diameter of the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="InnerRadius_0BzKrHVxX7DRQKw9ZKPhnG" GlobalId="0BzKrHVxX7DRQKw9ZKPhnG" Name="InnerRadius" Description="The inner radius of the element." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="InputFlowrate_1w_Iq0qRqHuO00025QrE$V" GlobalId="1w_Iq0qRqHuO00025QrE$V" Name="InputFlowrate" Description="Maximum input flowrate requirement.

Hydraulic flowrate." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="InputFlowrate_2YJ$e0qRqHuO00025QrE$V" GlobalId="2YJ$e0qRqHuO00025QrE$V" Name="InputFlowrate" Description="Maximum input flowrate requirement.

Control air flowrate." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="InputPower_3uTse0qSeHuO00025QrE$V" GlobalId="3uTse0qSeHuO00025QrE$V" Name="InputPower" Description="Input power to the compressor motor." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="InputPressure_1rc_A0qRqHuO00025QrE$V" GlobalId="1rc_A0qRqHuO00025QrE$V" Name="InputPressure" Description="Maximum input or design pressure for the object.

Maximum design pressure for the actuator." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="InputPressure_2SMXa0qRqHuO00025QrE$V" GlobalId="2SMXa0qRqHuO00025QrE$V" Name="InputPressure" Description="Maximum input or design pressure for the object.

Control air pressure." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="InputSignalType_3mt7oNhWL3QuPz1Q2ybJCo" GlobalId="3mt7oNhWL3QuPz1Q2ybJCo" Name="InputSignalType" Description="The type of the input signal." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" id="i1540" Name="PEnum_InputOutputSignalType">
						<EnumerationValues>
							<IfcLabel-wrapper>CURRENT</IfcLabel-wrapper>
							<IfcLabel-wrapper>VOLTAGE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="InsertedDeviceDiameter_3V8MuRReb9K8uXog2uN4dH" GlobalId="3V8MuRReb9K8uXog2uN4dH" Name="InsertedDeviceDiameter" Description="Diameter of the device inserted into the drillhole." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="InsideDiameter_2VCoa0qX8HuO00025QrE$V" GlobalId="2VCoa0qX8HuO00025QrE$V" Name="InsideDiameter" Description="Actual inner diameter of the tube in the tube bundle." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="InSituStress_3raVy7oj187xRtL6ooBSHH" GlobalId="3raVy7oj187xRtL6ooBSHH" Name="InSituStress" Description="Anisotropic stress regime, with direction and magnitude of principal stresses." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="InspectionChamberInvertLevel_2UBjS0qTCHuO00025QrE$V" GlobalId="2UBjS0qTCHuO00025QrE$V" Name="InspectionChamberInvertLevel" Description="Level of the lowest part of the cross section as measured from ground level." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="InstabilityFactors_06AWQ0_jj70ukx9CZSEl7o" GlobalId="06AWQ0_jj70ukx9CZSEl7o" Name="InstabilityFactors" Description="Defining values: slenderness ratios; defined values: either factors or divisors of the strength, depending on the design method (if &lt;1: factors, if &gt;1: divisors)." TemplateType="p_tablevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" SecondaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="InstabilityFactors_0xqstoxIX4bRDLvpeP1qs$" GlobalId="0xqstoxIX4bRDLvpeP1qs$" Name="InstabilityFactors" Description="Defining values: slenderness ratios; defined values: either factors or divisors of the strength, depending on the design method (if &lt;1: factors, if &gt;1: divisors)." TemplateType="p_tablevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" SecondaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="InstabilityFactors_3RdbqocJXF8uEl6oXjVCGl" GlobalId="3RdbqocJXF8uEl6oXjVCGl" Name="InstabilityFactors" Description="Defining values: slenderness ratios; defined values: either factors or divisors of the strength, depending on the design method (if &lt;1: factors, if &gt;1: divisors)." TemplateType="p_tablevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" SecondaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="InstallationDate_2k4h6AVrL8EBlzWRArJDjn" GlobalId="2k4h6AVrL8EBlzWRArJDjn" Name="InstallationDate" Description="Date on which the element is installed." TemplateType="p_singlevalue" PrimaryMeasureType="IfcDate" />
				<IfcSimplePropertyTemplate id="InstallationMethod_1y3E9FdGDDcuFQAiNae6DC" GlobalId="1y3E9FdGDDcuFQAiNae6DC" Name="InstallationMethod" Description="Method of installation of cable/conductor. Installation methods are typically defined by reference in standards such as IEC 60364-5-52, table 52A-1 or BS7671 Appendix 4 Table 4A1 etc. Selection of the value to be used should be determined from such a standard according to local usage." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="InstallationMethodFlagEnum_2_Nz3RdYDAXBJWTsAWu6NX" GlobalId="2_Nz3RdYDAXBJWTsAWu6NX" Name="InstallationMethodFlagEnum" Description="Special installation conditions relating to particular types of installation based on IEC60364-5-52:2001 reference installation methods C and D." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_InstallationMethodFlagEnum">
						<EnumerationValues>
							<IfcLabel-wrapper>INDUCT</IfcLabel-wrapper>
							<IfcLabel-wrapper>INSOIL</IfcLabel-wrapper>
							<IfcLabel-wrapper>ONWALL</IfcLabel-wrapper>
							<IfcLabel-wrapper>BELOWCEILING</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="InstallationPlan_1$TLUfKkH5dRWTorjafyVb" GlobalId="1$TLUfKkH5dRWTorjafyVb" Name="InstallationPlan" Description="Reference to external information source about installation or construction plan of the element." TemplateType="p_referencevalue" PrimaryMeasureType="IfcDocumentReference" SecondaryMeasureType="IfcValue" />
				<IfcSimplePropertyTemplate id="InstallationPlan_2beGsManD6zPMmBIW4LY_Q" GlobalId="2beGsManD6zPMmBIW4LY_Q" Name="InstallationPlan" Description="Reference to external information source about installation or construction plan of the element." TemplateType="p_referencevalue" PrimaryMeasureType="IfcExternalReference" />
				<IfcSimplePropertyTemplate id="InstalledCondition_0goJ6tJj9ExRS1Ys1pKvH9" GlobalId="0goJ6tJj9ExRS1Ys1pKvH9" Name="InstalledCondition" Description="Assessment of the condition of the element at point of installation." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_InstalledCondition">
						<EnumerationValues>
							<IfcLabel-wrapper>REGENERATED</IfcLabel-wrapper>
							<IfcLabel-wrapper>REUSED</IfcLabel-wrapper>
							<IfcLabel-wrapper>NEW</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="InstantaneousCurrentSetValue_0xvitUc492iA3MH7Yy4c1_" GlobalId="0xvitUc492iA3MH7Yy4c1_" Name="InstantaneousCurrentSetValue" Description="Instantaneous current set value. The set value of the instantaneous tripping current if adjustable." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="InstantaneousTrippingTime_2NQdbM51T95AtD0w7EUzy_" GlobalId="2NQdbM51T95AtD0w7EUzy_" Name="InstantaneousTrippingTime" Description="Instantaneous tripping time. The set value of the instantaneous tripping time if adjustable." TemplateType="p_singlevalue" PrimaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="InsulationMethod_1_Ub8uyHX2dgCLYmh2_Ttw" GlobalId="1_Ub8uyHX2dgCLYmh2_Ttw" Name="InsulationMethod" Description="The method used to insulate." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_InsulatorType">
						<EnumerationValues>
							<IfcLabel-wrapper>LONGRODINSULATOR</IfcLabel-wrapper>
							<IfcLabel-wrapper>PININSULATOR</IfcLabel-wrapper>
							<IfcLabel-wrapper>POSTINSULATOR</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="InsulationResistance_1ZlGxOxPPFmwm2gfaKJrQQ" GlobalId="1ZlGxOxPPFmwm2gfaKJrQQ" Name="InsulationResistance" Description="Minimum resistance between one terminal or several terminals connected together and the case or enclosure of a component at specified voltage." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricResistanceMeasure" />
				<IfcSimplePropertyTemplate id="InsulationStandardClass_1TFB_0qTyHuO00025QrE$V" GlobalId="1TFB_0qTyHuO00025QrE$V" Name="InsulationStandardClass" Description="Insulation standard classes provides basic protection information against electric shock. Defines levels of insulation required in terms of constructional requirements (creepage and clearance distances) and electrical requirements (compliance with electric strength tests). Basic insulation is considered to be shorted under single fault conditions. The actual values required depend on the working voltage to which the insulation is subjected, as well as other factors. Also indicates whether the electrical device has a protective earth connection." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_InsulationStandardClass">
						<EnumerationValues>
							<IfcLabel-wrapper>CLASS0APPLIANCE</IfcLabel-wrapper>
							<IfcLabel-wrapper>CLASS0IAPPLIANCE</IfcLabel-wrapper>
							<IfcLabel-wrapper>CLASSIAPPLIANCE</IfcLabel-wrapper>
							<IfcLabel-wrapper>CLASSIIAPPLIANCE</IfcLabel-wrapper>
							<IfcLabel-wrapper>CLASSIIIAPPLIANCE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="InsulationVoltage_0bnlOizRrA7828DVf4FSKA" GlobalId="0bnlOizRrA7828DVf4FSKA" Name="InsulationVoltage" Description="The insulation voltage.

It indicates the wire-to-ground (metal sheath) insulation voltage or the insulation voltage between the wires." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricVoltageMeasure" />
				<IfcSimplePropertyTemplate id="IntegerRange_2H3kc0qSqHuO00025QrE$V" GlobalId="2H3kc0qSqHuO00025QrE$V" Name="IntegerRange" Description="The physical range of values supported by the device." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcInteger" />
				<IfcSimplePropertyTemplate id="IntegralConstant_3cuv60qSqHuO00025QrE$V" GlobalId="3cuv60qSqHuO00025QrE$V" Name="IntegralConstant" Description="The integral gain factor of the controller (usually referred to as Ki). Asserted where ControlType is PROPORTIONALINTEGRAL or PROPORTIONALINTEGRALDERIVATIVE." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="IntegratedLightingType_0LhZU0qSyHuO00025QrE$V" GlobalId="0LhZU0qSyHuO00025QrE$V" Name="IntegratedLightingType" Description="Integrated lighting in cooled beam." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_CooledBeamIntegratedLightingType">
						<EnumerationValues>
							<IfcLabel-wrapper>NONE</IfcLabel-wrapper>
							<IfcLabel-wrapper>DIRECT</IfcLabel-wrapper>
							<IfcLabel-wrapper>INDIRECT</IfcLabel-wrapper>
							<IfcLabel-wrapper>DIRECTANDINDIRECT</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="InteriorHeatTransferCoefficient_1deOu0qSmHuO00025QrE$V" GlobalId="1deOu0qSmHuO00025QrE$V" Name="InteriorHeatTransferCoefficient" Description="Interior heat transfer coefficient associated with interior surface area." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcThermalTransmittanceMeasure" />
				<IfcSimplePropertyTemplate id="InteriorHeatTransferCoefficient_3Km1u0qU8HuO00025QrE$V" GlobalId="3Km1u0qU8HuO00025QrE$V" Name="InteriorHeatTransferCoefficient" Description="Interior heat transfer coefficient associated with interior surface area." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcThermalTransmittanceMeasure" />
				<IfcSimplePropertyTemplate id="InteriorRoughnessCoefficient_0kSXc0qTuHuO00025QrE$V" GlobalId="0kSXc0qTuHuO00025QrE$V" Name="InteriorRoughnessCoefficient" Description="The interior roughness of the material of the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="InteriorRoughnessCoefficient_39TEw0qV8HuO00025QrE$V" GlobalId="39TEw0qV8HuO00025QrE$V" Name="InteriorRoughnessCoefficient" Description="The interior roughness of the material of the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="InteriorRoughnessCoefficient_3WzQo0qTqHuO00025QrE$V" GlobalId="3WzQo0qTqHuO00025QrE$V" Name="InteriorRoughnessCoefficient" Description="The interior roughness of the material of the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="Intermittent_0XfFG0qUKHuO00025QrE$V" GlobalId="0XfFG0qUKHuO00025QrE$V" Name="Intermittent" Description="If fillet weld, intermittent or not" TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="InternalControl_3fK_I0qUaHuO00025QrE$V" GlobalId="3fK_I0qUaHuO00025QrE$V" Name="InternalControl" Description="Internal modulation control." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_HumidifierInternalControl">
						<EnumerationValues>
							<IfcLabel-wrapper>ONOFF</IfcLabel-wrapper>
							<IfcLabel-wrapper>STEPPED</IfcLabel-wrapper>
							<IfcLabel-wrapper>MODULATING</IfcLabel-wrapper>
							<IfcLabel-wrapper>NONE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="InternalLocation_2nkZ9bhLfFOumuCOVP2als" GlobalId="2nkZ9bhLfFOumuCOVP2als" Name="InternalLocation" Description="An organization defined address for internal mail delivery." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="InternalRefrigerantVolume_1S3P60qUCHuO00025QrE$V" GlobalId="1S3P60qUCHuO00025QrE$V" Name="InternalRefrigerantVolume" Description="Internal volume of object (refrigerant side)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumeMeasure" />
				<IfcSimplePropertyTemplate id="InternalRefrigerantVolume_2yHGa0qSmHuO00025QrE$V" GlobalId="2yHGa0qSmHuO00025QrE$V" Name="InternalRefrigerantVolume" Description="Internal volume of object (refrigerant side)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumeMeasure" />
				<IfcSimplePropertyTemplate id="InternalSurfaceArea_1Mi4S0qUCHuO00025QrE$V" GlobalId="1Mi4S0qUCHuO00025QrE$V" Name="InternalSurfaceArea" Description="Internal surface area." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAreaMeasure" />
				<IfcSimplePropertyTemplate id="InternalSurfaceArea_2svxw0qSmHuO00025QrE$V" GlobalId="2svxw0qSmHuO00025QrE$V" Name="InternalSurfaceArea" Description="Internal surface area." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAreaMeasure" />
				<IfcSimplePropertyTemplate id="InternalWaterVolume_1XQjm0qUCHuO00025QrE$V" GlobalId="1XQjm0qUCHuO00025QrE$V" Name="InternalWaterVolume" Description="Internal volume of object (water side)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumeMeasure" />
				<IfcSimplePropertyTemplate id="InternalWaterVolume_31ebE0qSmHuO00025QrE$V" GlobalId="31ebE0qSmHuO00025QrE$V" Name="InternalWaterVolume" Description="Internal volume of object (water side)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumeMeasure" />
				<IfcSimplePropertyTemplate id="InternalWidth_3Rero0qVCHuO00025QrE$V" GlobalId="3Rero0qVCHuO00025QrE$V" Name="InternalWidth" Description="The internal width of the culvert." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="InUse_0KMEUwmITB4x_YwcSfAiOX" GlobalId="0KMEUwmITB4x_YwcSfAiOX" Name="InUse" Description="Indicates whether the fiber has been assigned to some specific use." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="InUseConditions_0th9Dg6mf2lwF0z9cCob3a" GlobalId="0th9Dg6mf2lwF0z9cCob3a" Name="InUseConditions" Description="Adjustment of the service life resulting from the effect of the conditions in which components are operating." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="InvertElevation_1vIbm0qVCHuO00025QrE$V" GlobalId="1vIbm0qVCHuO00025QrE$V" Name="InvertElevation" Description="The invert elevation relative to the datum established for the project." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="InvertLevel_29dmw0qTGHuO00025QrE$V" GlobalId="29dmw0qTGHuO00025QrE$V" Name="InvertLevel" Description="Level of the lowest part of the cross section as measured from ground level." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="InvertLevel_3tbmO0qTCHuO00025QrE$V" GlobalId="3tbmO0qTCHuO00025QrE$V" Name="InvertLevel" Description="Level of the lowest part of the cross section as measured from ground level." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="IP_Code_1MhaW0qTyHuO00025QrE$V" GlobalId="1MhaW0qTyHuO00025QrE$V" Name="IP_Code" Description="IP Code, the International Protection Marking, IEC 60529), classifies and rates the degree of protection provided against intrusion." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="IP_Code_3c3IY0qUeHuO00025QrE$V" GlobalId="3c3IY0qUeHuO00025QrE$V" Name="IP_Code" Description="IP Code, the International Protection Marking, IEC 60529), classifies and rates the degree of protection provided against intrusion." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="IsAbsorbingEnergy_3kE48CR$D6Sg0O8bEZ6wBy" GlobalId="3kE48CR$D6Sg0O8bEZ6wBy" Name="IsAbsorbingEnergy" Description="Indicates whether the bumper absorbs energy or not." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsAccessibleByVehicle_3R5N45JWj9UumSu_fUKeWz" GlobalId="3R5N45JWj9UumSu_fUKeWz" Name="IsAccessibleByVehicle" Description="Indicates whether the element is accessible by a vehicle or not." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsAccessibleOnFoot_31J5jTh9z80B8lERH0gDCc" GlobalId="31J5jTh9z80B8lERH0gDCc" Name="IsAccessibleOnFoot" Description="Indicates whether the element is accessible on foot (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsAdjustable_00OvkE_Rn4KBS$xE3fF5xV" GlobalId="00OvkE_Rn4KBS$xE3fF5xV" Name="IsAdjustable" Description="Indicates whether the element is adjustable or not." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsAisle_056xA0qWiHuO00025QrE$V" GlobalId="056xA0qWiHuO00025QrE$V" Name="IsAisle" Description="Indicates that this parking zone is for accessing the parking units, i.e. an aisle (TRUE) and not a parking unit itself (FALSE)" TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsArcSuppressing_2bj3cZYAD7qvpndHNlg9vP" GlobalId="2bj3cZYAD7qvpndHNlg9vP" Name="IsArcSuppressing" Description="Indicates whether the element has the ability to suppress an arc." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsArticulatedBlade_3_6yRUpZDBOvmNhnWeL_XS" GlobalId="3_6yRUpZDBOvmNhnWeL_XS" Name="IsArticulatedBlade" Description="Indicates whether the blade is articulated or not." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsAutomatic_0M7F60qXGHuO00025QrE$V" GlobalId="0M7F60qXGHuO00025QrE$V" Name="IsAutomatic" Description="Indication of whether the valve is automatically operated (TRUE) or manually operated (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsAutomaticFlush_2SoDC0qW8HuO00025QrE$V" GlobalId="2SoDC0qW8HuO00025QrE$V" Name="IsAutomaticFlush" Description="Boolean value that determines if the cistern is flushed automatically either after each use or periodically (TRUE) or whether manual flushing is required (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsBidirectional_3PYJ6a4gXACx94JYuDo4no" GlobalId="3PYJ6a4gXACx94JYuDo4no" Name="IsBidirectional" Description="Indicates whether the turnstile is bidirectional." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsBoreholeCased_3JVj8MPWf9XRh6qY4yPdAo" GlobalId="3JVj8MPWf9XRh6qY4yPdAo" Name="IsBoreholeCased" Description="Specifies whether the boreholes are cased or not." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsBuiltIn_0VtI_0qUaHuO00025QrE$V" GlobalId="0VtI_0qUaHuO00025QrE$V" Name="IsBuiltIn" Description="Indicates whether the furniture type is intended to be &apos;built in&apos; i.e. physically attached to a building or facility (= TRUE) or not i.e. Loose and movable (= FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsCoated_1f9u80qTqHuO00025QrE$V" GlobalId="1f9u80qTqHuO00025QrE$V" Name="IsCoated" Description="Indication whether the glass is coated with a material (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsContaminatedSleeper_3veUeXa7v4mhaYZbSgpKpE" GlobalId="3veUeXa7v4mhaYZbSgpKpE" Name="IsContaminatedSleeper" Description="Indicates whether the sleeper is contaminated and requires special disposal or not." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsCovered_2YzvRQEzP4dh97Y5815zNr" GlobalId="2YzvRQEzP4dh97Y5815zNr" Name="IsCovered" Description="This property defines if the drain channel has a cover (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsCurrentCarrying_2T0h_sw_H3s8fsIzbCjbLk" GlobalId="2T0h_sw_H3s8fsIzbCjbLk" Name="IsCurrentCarrying" Description="To indicate whether the current will go through the dropper." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsCurrentTolerancePositiveOnly_1jOfW0qViHuO00025QrE$V" GlobalId="1jOfW0qViHuO00025QrE$V" Name="IsCurrentTolerancePositiveOnly" Description="Indication whether the value of CurrentTolerance1 is provided as a positive tolereance only or not. If not, the value is proved as a pluss/minus tolerance." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsCurrentTolerancePositiveOnly_1pf4I0qVeHuO00025QrE$V" GlobalId="1pf4I0qVeHuO00025QrE$V" Name="IsCurrentTolerancePositiveOnly" Description="Indication whether the value of CurrentTolerance1 is provided as a positive tolereance only or not. If not, the value is proved as a pluss/minus tolerance." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsCurrentTolerancePositiveOnly_3YWPs0qVeHuO00025QrE$V" GlobalId="3YWPs0qVeHuO00025QrE$V" Name="IsCurrentTolerancePositiveOnly" Description="Indication whether the value of CurrentTolerance1 is provided as a positive tolereance only or not. If not, the value is proved as a pluss/minus tolerance." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsCWRJoint_2aTez2BlX6R85Py6sJk$MW" GlobalId="2aTez2BlX6R85Py6sJk$MW" Name="IsCWRJoint" Description="Indicates if the rail joint is associated to a continuous welded rail." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsDerailing_3hK6$ugfj2heMnYkSgFRIQ" GlobalId="3hK6$ugfj2heMnYkSgFRIQ" Name="IsDerailing" Description="Indicates whether the derailer is on or not." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsDriveDirectedAlongChainage_3rVlZS58jDAw9PXxvdgGeO" GlobalId="3rVlZS58jDAw9PXxvdgGeO" Name="IsDriveDirectedAlongChainage" Description="Specifies whether the tunnel drive direction agrees with the positive chainage direction (true) or if the tunnel drive direction is reversed (false)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsElectricallyInsulated_1HhghvvaLAvfFIOypPw7B9" GlobalId="1HhghvvaLAvfFIOypPw7B9" Name="IsElectricallyInsulated" Description="Indicates whether the sleeper is electrically insulated due to its design or the running rails or not." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsElectrified_3fjp6BiNH8WQOXnO69XO80" GlobalId="3fjp6BiNH8WQOXnO69XO80" Name="IsElectrified" Description="Indicates whether the track system is electrified or not." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsentropicEfficiency_3j93w0qSeHuO00025QrE$V" GlobalId="3j93w0qSeHuO00025QrE$V" Name="IsentropicEfficiency" Description="Ratio of the work required for isentropic compression of the gas to work input to the compressor shaft." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="IsExceptionalTransportRoute_1UpphLsIf8AQz1eoTOneG9" GlobalId="1UpphLsIf8AQz1eoTOneG9" Name="IsExceptionalTransportRoute" Description="Indicates whether the route is suitable for exceptional transport (load, structure gauge, road)," TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsExtendedWarranty_0PiNW0qXOHuO00025QrE$V" GlobalId="0PiNW0qXOHuO00025QrE$V" Name="IsExtendedWarranty" Description="Indication of whether this is an extended warranty whose duration is greater than that normally assigned to an artefact (=TRUE) or not (= FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsExternal_0AhTG0qTmHuO00025QrE$V" GlobalId="0AhTG0qTmHuO00025QrE$V" Name="IsExternal" Description="Indication whether the element is designed for use in the exterior (TRUE) or not (FALSE). If (TRUE) it is an external element and faces the outside of the building." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsExternal_0d3pW0qVyHuO00025QrE$V" GlobalId="0d3pW0qVyHuO00025QrE$V" Name="IsExternal" Description="Indication whether the element is designed for use in the exterior (TRUE) or not (FALSE). If (TRUE) it is an external element and faces the outside of the building." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsExternal_0e$iimlYf0nf_mS3leF5wV" GlobalId="0e$iimlYf0nf_mS3leF5wV" Name="IsExternal" Description="Indication whether the element is designed for use in the exterior (TRUE) or not (FALSE). If (TRUE) it is an external element and faces the outside of the building." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsExternal_0eRpy0qSGHuO00025QrE$V" GlobalId="0eRpy0qSGHuO00025QrE$V" Name="IsExternal" Description="Indication whether the element is designed for use in the exterior (TRUE) or not (FALSE). If (TRUE) it is an external element and faces the outside of the building." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsExternal_0JQiu0qWqHuO00025QrE$V" GlobalId="0JQiu0qWqHuO00025QrE$V" Name="IsExternal" Description="Indication whether the element is designed for use in the exterior (TRUE) or not (FALSE). If (TRUE) it is an external element and faces the outside of the building." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsExternal_0ORrE0qVGHuO00025QrE$V" GlobalId="0ORrE0qVGHuO00025QrE$V" Name="IsExternal" Description="Indication whether the element is designed for use in the exterior (TRUE) or not (FALSE). If (TRUE) it is an external element and faces the outside of the building." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsExternal_0qVF00qWWHuO00025QrE$V" GlobalId="0qVF00qWWHuO00025QrE$V" Name="IsExternal" Description="Indication whether the element is designed for use in the exterior (TRUE) or not (FALSE). If (TRUE) it is an external element and faces the outside of the building." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsExternal_0wumB732b2A8dsysfeuKf4" GlobalId="0wumB732b2A8dsysfeuKf4" Name="IsExternal" Description="Indication whether the element is designed for use in the exterior (TRUE) or not (FALSE). If (TRUE) it is an external element and faces the outside of the building." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsExternal_16YMy0qSKHuO00025QrE$V" GlobalId="16YMy0qSKHuO00025QrE$V" Name="IsExternal" Description="Indication whether the element is designed for use in the exterior (TRUE) or not (FALSE). If (TRUE) it is an external element and faces the outside of the building." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsExternal_1Bd_k0qT0HuO00025QrE$V" GlobalId="1Bd_k0qT0HuO00025QrE$V" Name="IsExternal" Description="Indication whether the element is designed for use in the exterior (TRUE) or not (FALSE). If (TRUE) it is an external element and faces the outside of the building." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsExternal_1frGu0qWSHuO00025QrE$V" GlobalId="1frGu0qWSHuO00025QrE$V" Name="IsExternal" Description="Indication whether the element is designed for use in the exterior (TRUE) or not (FALSE). If (TRUE) it is an external element and faces the outside of the building." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsExternal_1GByY0qVyHuO00025QrE$V" GlobalId="1GByY0qVyHuO00025QrE$V" Name="IsExternal" Description="Indication whether the element is designed for use in the exterior (TRUE) or not (FALSE). If (TRUE) it is an external element and faces the outside of the building." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsExternal_1kZiU0qV4HuO00025QrE$V" GlobalId="1kZiU0qV4HuO00025QrE$V" Name="IsExternal" Description="Indication whether the element is designed for use in the exterior (TRUE) or not (FALSE). If (TRUE) it is an external element and faces the outside of the building." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsExternal_1ScIw0qSaHuO00025QrE$V" GlobalId="1ScIw0qSaHuO00025QrE$V" Name="IsExternal" Description="Indication whether the element is designed for use in the exterior (TRUE) or not (FALSE). If (TRUE) it is an external element and faces the outside of the building." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsExternal_1tk6u0qSeHuO00025QrE$V" GlobalId="1tk6u0qSeHuO00025QrE$V" Name="IsExternal" Description="Indication whether the element is designed for use in the exterior (TRUE) or not (FALSE). If (TRUE) it is an external element and faces the outside of the building." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsExternal_2cEKU0qT0HuO00025QrE$V" GlobalId="2cEKU0qT0HuO00025QrE$V" Name="IsExternal" Description="Indication whether the element is designed for use in the exterior (TRUE) or not (FALSE). If (TRUE) it is an external element and faces the outside of the building." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsExternal_2zH5s0qW4HuO00025QrE$V" GlobalId="2zH5s0qW4HuO00025QrE$V" Name="IsExternal" Description="Indication whether the element is designed for use in the exterior (TRUE) or not (FALSE). If (TRUE) it is an external element and faces the outside of the building." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsExternal_3D6sm0qXWHuO00025QrE$V" GlobalId="3D6sm0qXWHuO00025QrE$V" Name="IsExternal" Description="Indication whether the element is designed for use in the exterior (TRUE) or not (FALSE). If (TRUE) it is an external element and faces the outside of the building." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsExternal_3t$SG0qWWHuO00025QrE$V" GlobalId="3t$SG0qWWHuO00025QrE$V" Name="IsExternal" Description="Indication whether the element is designed for use in the exterior (TRUE) or not (FALSE). If (TRUE) it is an external element and faces the outside of the building." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsExternal_3VVh40qUeHuO00025QrE$V" GlobalId="3VVh40qUeHuO00025QrE$V" Name="IsExternal" Description="Indication whether the element is designed for use in the exterior (TRUE) or not (FALSE). If (TRUE) it is an external element and faces the outside of the building." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsExternal_3wicPbQZz5Ru6Zjj9F$4Lp" GlobalId="3wicPbQZz5Ru6Zjj9F$4Lp" Name="IsExternal" Description="Indication whether the element is designed for use in the exterior (TRUE) or not (FALSE). If (TRUE) it is an external element and faces the outside of the building." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsExternal_3Yss80qXKHuO00025QrE$V" GlobalId="3Yss80qXKHuO00025QrE$V" Name="IsExternal" Description="Indication whether the element is designed for use in the exterior (TRUE) or not (FALSE). If (TRUE) it is an external element and faces the outside of the building." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsFallbackBlade_0mvKptGVb02xCOJPjqgmF6" GlobalId="0mvKptGVb02xCOJPjqgmF6" Name="IsFallbackBlade" Description="Indicates whether the blade always returns to the same position as a trailable turnout or not." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsFireResistant_0EDQmMlDr4wOieHoEptGkG" GlobalId="0EDQmMlDr4wOieHoEptGkG" Name="IsFireResistant" Description="Indicates whether the cable is fire resistant." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsFOB_3ZPG00qVSHuO00025QrE$V" GlobalId="3ZPG00qVSHuO00025QrE$V" Name="IsFOB" Description="Indication of whether contents of the purchase order are delivered &apos;Free on Board&apos; (= True) or not (= False). FOB is a shipping term which indicates that the supplier pays the shipping costs (and usually also the insurance costs) from the point of manufacture to a specified destination, at which point the buyer takes responsibility." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsForSullageWater_1rV040qXOHuO00025QrE$V" GlobalId="1rV040qXOHuO00025QrE$V" Name="IsForSullageWater" Description="Indicates if the purpose of the floor trap is to receive sullage water, or if that is amongst its purposes (= TRUE), or not (= FALSE). Note that if TRUE, it is expected that an upstand or kerb will be placed around the floor trap to prevent the ingress of surface water runoff; the provision of the upstand or kerb is not dealt with in this property set." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsFreeHanging_2$sO_0qSuHuO00025QrE$V" GlobalId="2$sO_0qSuHuO00025QrE$V" Name="IsFreeHanging" Description="Is it free hanging type (not mounted in a false ceiling)?" TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsFreshwater_1KdzyKr5b5KxvuHaCdKWAs" GlobalId="1KdzyKr5b5KxvuHaCdKWAs" Name="IsFreshwater" Description="Indication of freshwater (true,false or unknown)" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLogical" />
				<IfcSimplePropertyTemplate id="IsGrouted_3uTqQIVjvEjAXvCwtg5l_m" GlobalId="3uTqQIVjvEjAXvCwtg5l_m" Name="IsGrouted" Description="Specifies whether the bar is grouted." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsGuarded_0LjpC0qU4HuO00025QrE$V" GlobalId="0LjpC0qU4HuO00025QrE$V" Name="IsGuarded" Description="Indication of whether the motor enclosure is guarded (= TRUE) or not (= FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsHighPressure_3ud5U0qXGHuO00025QrE$V" GlobalId="3ud5U0qXGHuO00025QrE$V" Name="IsHighPressure" Description="Indication of whether the flushing valve is suitable for use on a high pressure water main (set TRUE) or not (set FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsHighType_1mNsJbl7z7nRsPj_JQtlc5" GlobalId="1mNsJbl7z7nRsPj_JQtlc5" Name="IsHighType" Description="Indicates if the signal is high (TRUE) or dwarf (ground mounted) (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsHollowSleeper_1_l7FDgPz3CgHhlHjyAHYa" GlobalId="1_l7FDgPz3CgHhlHjyAHYa" Name="IsHollowSleeper" Description="Indicates whether the sleeper is hollowed or not." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsHorizontalBusbar_0U0dI0qSSHuO00025QrE$V" GlobalId="0U0dI0qSSHuO00025QrE$V" Name="IsHorizontalBusbar" Description="Indication of whether the busbar occurrences are routed horizontally (= TRUE) or vertically (= FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsHorizontalCable_3Kx2SOOpDE7gZDqQ7MF7S8" GlobalId="3Kx2SOOpDE7gZDqQ7MF7S8" Name="IsHorizontalCable" Description="Indication of whether the cable occurrences are mounted horizontally (= TRUE) or vertically (= FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsIlluminated_3KYKW0qWqHuO00025QrE$V" GlobalId="3KYKW0qWqHuO00025QrE$V" Name="IsIlluminated" Description="An indication of whether there is an illuminated indicator to show that the switch is on (=TRUE) or not (= FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsInsulated_0Eq$IgBvz97uWvPsoTH$G9" GlobalId="0Eq$IgBvz97uWvPsoTH$G9" Name="IsInsulated" Description="Indicates whether the element is insulated or not." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsJointControlEquipment_1y8uHbp6z5vfRtA_1nm6D8" GlobalId="1y8uHbp6z5vfRtA_1nm6D8" Name="IsJointControlEquipment" Description="Indicates whether security equipment is checking the mechanical functionality of the rail joint." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsJointInsulated_0V_bDkEFz0MBUJ_PVJB5bz" GlobalId="0V_bDkEFz0MBUJ_PVJB5bz" Name="IsJointInsulated" Description="Indicates if the rail joint is insulated." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsLaminated_1Tr5Q0qTqHuO00025QrE$V" GlobalId="1Tr5Q0qTqHuO00025QrE$V" Name="IsLaminated" Description="Indication whether the glass is layered with other materials (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsLandmarked_0gXSs0qSKHuO00025QrE$V" GlobalId="0gXSs0qSKHuO00025QrE$V" Name="IsLandmarked" Description="This builing is listed as a historic building (TRUE), or not (FALSE), or unknown." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLogical" />
				<IfcSimplePropertyTemplate id="IsLiftingBracket_0Py8wuJJrAwPXDvufAW9rN" GlobalId="0Py8wuJJrAwPXDvufAW9rN" Name="IsLiftingBracket" Description="Indicates whether the connection is done between rail with different height (TRUE) or with same height (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsLiftingBracketConnection_0b7QU$LAbEywG5aCANU6MN" GlobalId="0b7QU$LAbEywG5aCANU6MN" Name="IsLiftingBracketConnection" Description="Indicates if the connection is between two different heights (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsLoadBearing_1Z0YsPaSfERxoftwuOR8uQ" GlobalId="1Z0YsPaSfERxoftwuOR8uQ" Name="IsLoadBearing" Description="Specifies whether the element is load bearing (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsLocked_2RDCAlPobEcu$7w2dT8CcG" GlobalId="2RDCAlPobEcu$7w2dT8CcG" Name="IsLocked" Description="Indicates whether the element is locked (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsMain_38kVnOpG9ExQCWZ$aM22lh" GlobalId="38kVnOpG9ExQCWZ$aM22lh" Name="IsMain" Description="Identifies if the current instance is a main distribution point or topmost level in an electrical distribution hierarchy (= TRUE) or a sub-main distribution point (= FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsMonitored_3KGj0PEan4G86e5DwEt_YL" GlobalId="3KGj0PEan4G86e5DwEt_YL" Name="IsMonitored" Description="This property defines if the Drain Channel is monitored (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsMountedFlatCable_0cChT80zD6mAhzFtp$7usP" GlobalId="0cChT80zD6mAhzFtp$7usP" Name="IsMountedFlatCable" Description="Indication of whether the cable occurrences are mounted flat (= TRUE) or in a trefoil pattern (= FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsMoveable_2PCpjtVLvAUPco$vP4wWML" GlobalId="2PCpjtVLvAUPco$vP4wWML" Name="IsMoveable" Description="True if element is moveable." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsNeutralPrimaryTerminalAvailable_3IAEq0qX4HuO00025QrE$V" GlobalId="3IAEq0qX4HuO00025QrE$V" Name="IsNeutralPrimaryTerminalAvailable" Description="An indication of whether the neutral point of the primary winding is available as a terminal (=TRUE) or not (= FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsNeutralSecondaryTerminalAvailable_3PJ$i0qX4HuO00025QrE$V" GlobalId="3PJ$i0qX4HuO00025QrE$V" Name="IsNeutralSecondaryTerminalAvailable" Description="An indication of whether the neutral point of the secondary winding is available as a terminal (=TRUE) or not (= FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsNormallyOpen_0IrZM0qXKHuO00025QrE$V" GlobalId="0IrZM0qXKHuO00025QrE$V" Name="IsNormallyOpen" Description="If TRUE, the valve is normally open. If FALSE is is normally closed." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsOffWhenLfunctionOn_258JATUR56lh3z1MtrEDz$" GlobalId="258JATUR56lh3z1MtrEDz$" Name="IsOffWhenLfunctionOn" Description="Indication whether the S-function is automatically switched off when the I-function is switched on." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsOffWhenSFunctionOn_2Zqd6j77r7GvBbph7l93Pd" GlobalId="2Zqd6j77r7GvBbph7l93Pd" Name="IsOffWhenSFunctionOn" Description="Indication whether the I-function is automatically switched off when the S-function is switched on." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsolatingPurpose_0QbTe0qXKHuO00025QrE$V" GlobalId="0QbTe0qXKHuO00025QrE$V" Name="IsolatingPurpose" Description="Defines the purpose for which the isolating valve is used since the way in which the valve is identified as an isolating valve may be in the context of its use. Note that unless there is a contextual name for the isolating valve (as in the case of a Landing Valve on a rising fire main), then the value assigned shoulkd be UNSET." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_IsolatingPurpose">
						<EnumerationValues>
							<IfcLabel-wrapper>LANDING</IfcLabel-wrapper>
							<IfcLabel-wrapper>LANDINGWITHPRESSUREREGULATION</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="IsolatorCompressibility_2BFFQ0qXKHuO00025QrE$V" GlobalId="2BFFQ0qXKHuO00025QrE$V" Name="IsolatorCompressibility" Description="The compressibility of the vibration isolator." TemplateType="p_singlevalue" PrimaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="IsolatorStaticDeflection_25twm0qXKHuO00025QrE$V" GlobalId="25twm0qXKHuO00025QrE$V" Name="IsolatorStaticDeflection" Description="Static deflection of the vibration isolator." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="IsOneWay_0CGi20qWiHuO00025QrE$V" GlobalId="0CGi20qWiHuO00025QrE$V" Name="IsOneWay" Description="Indicates whether the parking aisle is designed for oneway traffic (TRUE) or twoway traffic (FALSE). Should only be provided if the property IsAisle is set to TRUE." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsothermalMoistureCapacity_1ZEPq0qUqHuO00025QrE$V" GlobalId="1ZEPq0qUqHuO00025QrE$V" Name="IsothermalMoistureCapacity" Description="Based on water vapor density." TemplateType="p_singlevalue" PrimaryMeasureType="IfcIsothermalMoistureCapacityMeasure" />
				<IfcSimplePropertyTemplate id="IsOutdoors_0ED660qS8HuO00025QrE$V" GlobalId="0ED660qS8HuO00025QrE$V" Name="IsOutdoors" Description="Indicates if camera is designed to be used outdoors." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsOutlookDesirable_3guTI0qWeHuO00025QrE$V" GlobalId="3guTI0qWeHuO00025QrE$V" Name="IsOutlookDesirable" Description="An indication of whether the outlook is desirable (set TRUE) or not (set FALSE)" TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsPermanentID_1pwHE0qUiHuO00025QrE$V" GlobalId="1pwHE0qUiHuO00025QrE$V" Name="IsPermanentID" Description="Indicates whether the identity assigned to the object is permanent (= TRUE) or temporary (=FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsPermanentID_3wFYy0qSGHuO00025QrE$V" GlobalId="3wFYy0qSGHuO00025QrE$V" Name="IsPermanentID" Description="Indicates whether the identity assigned to the object is permanent (= TRUE) or temporary (=FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsPiezometric_1c5OF998b1_8SQzyRB0_vU" GlobalId="1c5OF998b1_8SQzyRB0_vU" Name="IsPiezometric" Description="Defines whether height measurements are made vs the piezometric surface (true) or the surface of the groundwater (false)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsPluggableOutlet_3e9hM0qV4HuO00025QrE$V" GlobalId="3e9hM0qV4HuO00025QrE$V" Name="IsPluggableOutlet" Description="Indication of whether the outlet accepts a loose plug connection (= TRUE) or whether it is directly connected (= FALSE) or whether the form of connection has not yet been determined (= UNKNOWN)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLogical" />
				<IfcSimplePropertyTemplate id="IsPotable_0XNIQ0qUuHuO00025QrE$V" GlobalId="0XNIQ0qUuHuO00025QrE$V" Name="IsPotable" Description="If TRUE, then the water is considered potable." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsPrivateOwner_1E7ZEm8I13sg3M3fKSTa3V" GlobalId="1E7ZEm8I13sg3M3fKSTa3V" Name="IsPrivateOwner" Description="Indicates if the owner of the crossed road is private or not." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsReducedResistanceFastening_0DOivAfc56c81gaVUiqBi8" GlobalId="0DOivAfc56c81gaVUiqBi8" Name="IsReducedResistanceFastening" Description="Indicates whether the rail fastening is a reduced resistance fastening (YES) or not (NO)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsReinforced_1Qp9XSGSD30AXUnzycyqDf" GlobalId="1Qp9XSGSD30AXUnzycyqDf" Name="IsReinforced" Description="Indicates whether the foundation is reinforced (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsRemovableBumper_3R8M736eTFRgejCUNrQPuL" GlobalId="3R8M736eTFRgejCUNrQPuL" Name="IsRemovableBumper" Description="Indicates if the bumper is removable or not." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsRigid_3qIKs0qSOHuO00025QrE$V" GlobalId="3qIKs0qSOHuO00025QrE$V" Name="IsRigid" Description="Indication of whether the conduit is rigid (= TRUE) or flexible (= FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsSecuredBySignalingSystem_3lKpC5tQT9EP06pEGEuocd" GlobalId="3lKpC5tQT9EP06pEGEuocd" Name="IsSecuredBySignalingSystem" Description="Indicates whether the level crossing is secured by a signalling system or not." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsSelectable_12n0_0qVeHuO00025QrE$V" GlobalId="12n0_0qVeHuO00025QrE$V" Name="IsSelectable" Description="Indication whether something can be switched off or not." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsSelfDrilling_3WwKwa3Qj80x3m3RM3jYw9" GlobalId="3WwKwa3Qj80x3m3RM3jYw9" Name="IsSelfDrilling" Description="Specifies whether the bar is self drilling." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsSelfLubricated_1$jckKQnr1M8meRe1yLTIe" GlobalId="1$jckKQnr1M8meRe1yLTIe" Name="IsSelfLubricated" Description="Indicates whether the element is self lubricated or not." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsSetOnWorkingWire_3iDlFQIQvDTx70HJm6uraY" GlobalId="3iDlFQIQvDTx70HJm6uraY" Name="IsSetOnWorkingWire" Description="Indicates whether the steady device is set on the working wire." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsShallow_0J0X40qTGHuO00025QrE$V" GlobalId="0J0X40qTGHuO00025QrE$V" Name="IsShallow" Description="Indicates whether the chamber has been designed as being shallow (TRUE) or deep (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsSharedTurnout_3ZDLci8DP06u1$Ft52yrEN" GlobalId="3ZDLci8DP06u1$Ft52yrEN" Name="IsSharedTurnout" Description="Indicates if the turnout makes a connection to another infrastructure owner (for sharing costs)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsSingleFlush_1zoa40qW8HuO00025QrE$V" GlobalId="1zoa40qW8HuO00025QrE$V" Name="IsSingleFlush" Description="Indicates whether the cistern is single flush = TRUE (i.e. the same amount of water is used for each and every flush) or dual flush = FALSE (i.e. the amount of water used for a flush may be selected by the user to be high or low depending on the waste material to be removed)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsSkilledOperator_126zTH3Fb7s9WfKr4C5g0Q" GlobalId="126zTH3Fb7s9WfKr4C5g0Q" Name="IsSkilledOperator" Description="Identifies if the current instance requires a skilled person or instructed person to perform operations on the distribution board (= TRUE) or whether operations may be performed by a person without appropriate skills or instruction (= FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsStainless_3o8$Mm6_13vB7BMsiZ5H6c" GlobalId="3o8$Mm6_13vB7BMsiZ5H6c" Name="IsStainless" Description="Indicates whether the rail is stainless or not." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsSunExposed_3jUxqj7iX3zerVO_VEXgG7" GlobalId="3jUxqj7iX3zerVO_VEXgG7" Name="IsSunExposed" Description="Indicates if the object is in exposed position to sunshine." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsSurfaceGalling_1ZjWQaS4v7yRtvDOWbc7uC" GlobalId="1ZjWQaS4v7yRtvDOWbc7uC" Name="IsSurfaceGalling" Description="Indicates whether the surface is galling or not." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsSwitch_0mw6c0qWOHuO00025QrE$V" GlobalId="0mw6c0qWOHuO00025QrE$V" Name="IsSwitch" Description="Identifies if the sensor also functions as a switch at the set point (=TRUE) or not (= FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsTempered_1Hw9I0qTqHuO00025QrE$V" GlobalId="1Hw9I0qTqHuO00025QrE$V" Name="IsTempered" Description="Indication whether the glass is tempered (TRUE) or not (FALSE) ." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsTemporary_1kVVwEVWv2m8yxnkRxkynp" GlobalId="1kVVwEVWv2m8yxnkRxkynp" Name="IsTemporary" Description="Indicates if the installation of the element is temporary or not." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsTemporaryInstallation_3I8hgbGqb2cwnJJlcup1s_" GlobalId="3I8hgbGqb2cwnJJlcup1s_" Name="IsTemporaryInstallation" Description="Indicates whether the installation (in the construction stage) is permanent (TRUE) or temporary (FALSE)" TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsTerminal_0Wg6oF21T7uegGAdhCCMvp" GlobalId="0Wg6oF21T7uegGAdhCCMvp" Name="IsTerminal" Description="True if element is a terminal. See class Terminal." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsTimeTolerancePositiveOnly_25qhA0qViHuO00025QrE$V" GlobalId="25qhA0qViHuO00025QrE$V" Name="IsTimeTolerancePositiveOnly" Description="Indication whether the value of TimeTolerance1 is provided as a positive tolereance only or not. If not, the value is proved as a pluss/minus tolerance." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsTimeTolerancePositiveOnly_2Aup80qVeHuO00025QrE$V" GlobalId="2Aup80qVeHuO00025QrE$V" Name="IsTimeTolerancePositiveOnly" Description="Indication whether the value of TimeTolerance1 is provided as a positive tolereance only or not. If not, the value is proved as a pluss/minus tolerance." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsTimeTolerancePositiveOnly_3vm8i0qVeHuO00025QrE$V" GlobalId="3vm8i0qVeHuO00025QrE$V" Name="IsTimeTolerancePositiveOnly" Description="Indication whether the value of TimeTolerance1 is provided as a positive tolereance only or not. If not, the value is proved as a pluss/minus tolerance." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsTopographic_2E3ZmSESz08wrQaLoH1SHI" GlobalId="2E3ZmSESz08wrQaLoH1SHI" Name="IsTopographic" Description="Is the stratum ever topmost and so a visible topographic feature" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLogical" />
				<IfcSimplePropertyTemplate id="IsTransition_3NMOg9ojPFzfUPLZ8yR9b$" GlobalId="3NMOg9ojPFzfUPLZ8yR9b$" Name="IsTransition" Description="True if element is a transition. See class Transition." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsUpgradable_2ZU8jJnSr22RzVeas8FkPD" GlobalId="2ZU8jJnSr22RzVeas8FkPD" Name="IsUpgradable" Description="Indicates whether the transport equipment can be upgraded or not." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsUsed_0M$rI0qWyHuO00025QrE$V" GlobalId="0M$rI0qWyHuO00025QrE$V" Name="IsUsed" Description="Indicates whether the element is being used in a workstation (= TRUE) or not.(= FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsWaterStorageHeater_2OVSK0qSGHuO00025QrE$V" GlobalId="2OVSK0qSGHuO00025QrE$V" Name="IsWaterStorageHeater" Description="This is used to identify if the boiler has storage capacity (TRUE). If FALSE, then there is no storage capacity built into the boiler, such as an instantaneous hot water heater." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsWelded_1ZxOPXMGT17eoWdZAFb$Ls" GlobalId="1ZxOPXMGT17eoWdZAFb$Ls" Name="IsWelded" Description="Indicates whether the wire pair end point is joined to another wire pair end point by means of a welded junction." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="IsWired_1o65E0qTqHuO00025QrE$V" GlobalId="1o65E0qTqHuO00025QrE$V" Name="IsWired" Description="Indication whether the glass includes a contained wire mesh to prevent break-in (TRUE) or not (FALSE)" TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="JacketColour_1vHztIiLn2ZvG$H5JLPMVP" GlobalId="1vHztIiLn2ZvG$H5JLPMVP" Name="JacketColour" Description="Indicates the colour of the cable or fitting jacket." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="JetGroutingMethod_1vOlBmVz9DAfg$mBl_DOiT" GlobalId="1vOlBmVz9DAfg$mBl_DOiT" Name="JetGroutingMethod" Description="Method of jet grouting." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_JetGroutingMethod">
						<EnumerationValues>
							<IfcLabel-wrapper>SINGLEPHASE</IfcLabel-wrapper>
							<IfcLabel-wrapper>TWOPHASE</IfcLabel-wrapper>
							<IfcLabel-wrapper>THREEPHASE</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="JointRelativePosition_06BnzJB6b9zhMKCUAtPkfJ" GlobalId="06BnzJB6b9zhMKCUAtPkfJ" Name="JointRelativePosition" Description="Indicates the relative position of the joint, which lies in the left or right rail or in the middle, or in combination. The left rail is to the left as facing in the direction of increasing stationing values, and the right rail is to the right." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" id="i1721" Name="PEnum_RelativePosition">
						<EnumerationValues>
							<IfcLabel-wrapper>LEFT</IfcLabel-wrapper>
							<IfcLabel-wrapper>RIGHT</IfcLabel-wrapper>
							<IfcLabel-wrapper>MIDDLE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="JunctionBoxMountingType_3EpZi0qUeHuO00025QrE$V" GlobalId="3EpZi0qUeHuO00025QrE$V" Name="JunctionBoxMountingType" Description="Method of mounting to be adopted for the type of junction box." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_JunctionBoxMountingType">
						<EnumerationValues>
							<IfcLabel-wrapper>FACENAIL</IfcLabel-wrapper>
							<IfcLabel-wrapper>SIDENAIL</IfcLabel-wrapper>
							<IfcLabel-wrapper>CUT_IN</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="JunctionLeftAngle_161yq0qVCHuO00025QrE$V" GlobalId="161yq0qVCHuO00025QrE$V" Name="JunctionLeftAngle" Description="The change of direction of flow for the left junction." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositivePlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="JunctionLeftRadius_1Ap840qVCHuO00025QrE$V" GlobalId="1Ap840qVCHuO00025QrE$V" Name="JunctionLeftRadius" Description="The radius of bending for the left junction." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="JunctionRightAngle_1J9Bm0qVCHuO00025QrE$V" GlobalId="1J9Bm0qVCHuO00025QrE$V" Name="JunctionRightAngle" Description="The change of direction of flow for the right junction where 0 indicates straight segment." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositivePlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="JunctionRightRadius_1NwN00qVCHuO00025QrE$V" GlobalId="1NwN00qVCHuO00025QrE$V" Name="JunctionRightRadius" Description="The radius of bending for the right junction where 0 indicates sharp bend." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="JunctionType_0vWtI0qVCHuO00025QrE$V" GlobalId="0vWtI0qVCHuO00025QrE$V" Name="JunctionType" Description="The type of junction. TEE=3 ports, CROSS = 4 ports." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_FittingJunctionType">
						<EnumerationValues>
							<IfcLabel-wrapper>CROSS</IfcLabel-wrapper>
							<IfcLabel-wrapper>TEE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="K_2jm5TRU9TFhudeUCIbbCmE" GlobalId="2jm5TRU9TFhudeUCIbbCmE" Name="K+" Description="Content of K+ in the water sample." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="K0_19WbY_VgHBFw4Tv8TsWyiH" GlobalId="19WbY_VgHBFw4Tv8TsWyiH" Name="K0" Description="The coefficient of lateral earth pressure, K, is defined as the ratio of the horizontal effective stress, σ’h, to the vertical effective stress, σ’v. For a level ground deposit with zero lateral strain in the soil, the &quot;at-rest&quot; coefficient of lateral earth pressure, K0 is obtained." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="K0_3LHWuSc4f4oAmYOduGjUmW" GlobalId="3LHWuSc4f4oAmYOduGjUmW" Name="K0" Description="Lateral Earth Pressure Coefficient." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="Karst_0AcIORqg96AgGOq$7Qdkzh" GlobalId="0AcIORqg96AgGOq$7Qdkzh" Name="Karst" Description="Description of expected or observed karst features." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="Karst_3P_YQ46mn8svjq87SZAWhd" GlobalId="3P_YQ46mn8svjq87SZAWhd" Name="Karst" Description="Description of expected or observed karst features." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="KeyDepth_3k7fM0qVKHuO00025QrE$V" GlobalId="3k7fM0qVKHuO00025QrE$V" Name="KeyDepth" Description="Key depth of the profile." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNonNegativeLengthMeasure" />
				<IfcSimplePropertyTemplate id="KeyHeight_3ouqc0qVKHuO00025QrE$V" GlobalId="3ouqc0qVKHuO00025QrE$V" Name="KeyHeight" Description="Key height of the profile." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNonNegativeLengthMeasure" />
				<IfcSimplePropertyTemplate id="KeyOffset_3tf$s0qVKHuO00025QrE$V" GlobalId="3tf$s0qVKHuO00025QrE$V" Name="KeyOffset" Description="Key offset of the profile." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNonNegativeLengthMeasure" />
				<IfcSimplePropertyTemplate id="KeypadType_0u4tM0qWuHuO00025QrE$V" GlobalId="0u4tM0qWuHuO00025QrE$V" Name="KeypadType" Description="A list of the available types of keypad switch from which that required may be selected." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_SwitchingDeviceKeypadType">
						<EnumerationValues>
							<IfcLabel-wrapper>BUTTONS</IfcLabel-wrapper>
							<IfcLabel-wrapper>TOUCHSCREEN</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="KeyShape_05fq_0qV4HuO00025QrE$V" GlobalId="05fq_0qV4HuO00025QrE$V" Name="KeyShape" Description="If applicable, shape of the head&apos;s slot, e.g. &apos;Slot&apos;, &apos;Allen&apos;" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="Labels_0W7060qSuHuO00025QrE$V" GlobalId="0W7060qSuHuO00025QrE$V" Name="Labels" Description="Table mapping values to labels

Labels indicate the meanings of True and False, such as &apos;Open&apos; and &apos;Closed&apos;" TemplateType="p_tablevalue" PrimaryMeasureType="IfcBoolean" SecondaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="Labels_1MfKo0qSqHuO00025QrE$V" GlobalId="1MfKo0qSqHuO00025QrE$V" Name="Labels" Description="Table mapping values to labels

Labels indicate transition points such as &apos;Hi&apos;, &apos;Lo&apos;, &apos;HiHi&apos;, or &apos;LoLo&apos;." TemplateType="p_tablevalue" PrimaryMeasureType="IfcReal" SecondaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="Labels_29vzk0qSqHuO00025QrE$V" GlobalId="29vzk0qSqHuO00025QrE$V" Name="Labels" Description="Table mapping values to labels

Each entry corresponds to an integer within the ValueRange." TemplateType="p_tablevalue" PrimaryMeasureType="IfcInteger" SecondaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="LadderConfiguration_232Pg0qSOHuO00025QrE$V" GlobalId="232Pg0qSOHuO00025QrE$V" Name="LadderConfiguration" Description="Description of the configuration of the ladder structure used." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="LadderTrussBaseBarDiameter_3ILSW0qT8HuO00025QrE$V" GlobalId="3ILSW0qT8HuO00025QrE$V" Name="LadderTrussBaseBarDiameter" Description="The nominal diameter of the base bar." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="LadderTrussCrossBarDiameter_3TgFE0qT8HuO00025QrE$V" GlobalId="3TgFE0qT8HuO00025QrE$V" Name="LadderTrussCrossBarDiameter" Description="The nominal diameter of the straight cross-bars." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="LadderTrussCrossBarSpacing_3DaHG0qT8HuO00025QrE$V" GlobalId="3DaHG0qT8HuO00025QrE$V" Name="LadderTrussCrossBarSpacing" Description="The spacing between the straight cross-bars." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="LadderTrussHeight_32FUY0qT8HuO00025QrE$V" GlobalId="32FUY0qT8HuO00025QrE$V" Name="LadderTrussHeight" Description="The overall height of the truss connector." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="LadderTrussLength_370fo0qT8HuO00025QrE$V" GlobalId="370fo0qT8HuO00025QrE$V" Name="LadderTrussLength" Description="The overall length of the truss connector." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="LadderTrussSecondaryBarDiameter_3OIwa0qT8HuO00025QrE$V" GlobalId="3OIwa0qT8HuO00025QrE$V" Name="LadderTrussSecondaryBarDiameter" Description="The nominal diameter of the secondary bar." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="LampBallastType_0YsH_0qUiHuO00025QrE$V" GlobalId="0YsH_0qUiHuO00025QrE$V" Name="LampBallastType" Description="The type of ballast used to stabilise gas discharge by limiting the current during operation and to deliver the necessary striking voltage for starting. Ballasts are needed to operate Discharge Lamps such as Fluorescent, Compact Fluorescent, High-pressure Mercury, Metal Halide and High-pressure Sodium Lamps.
Magnetic ballasts are chokes which limit the current passing through a lamp connected in series on the principle of self-induction. The resultant current and power are decisive for the efficient operation of the lamp. A specially designed ballast is required for every type of lamp to comply with lamp rating in terms of Luminous Flux, Color Appearance and service life. The two types of magnetic ballasts for fluorescent lamps are KVG Conventional   (EC-A series) and VVG Low-loss ballasts (EC-B series). Low-loss ballasts have a higher efficiency, which means reduced ballast losses and a lower thermal load. Electronic ballasts are used to run fluorescent lamps at high frequencies (approx. 35 - 40 kHz)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_LampBallastType">
						<EnumerationValues>
							<IfcLabel-wrapper>CONVENTIONAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>ELECTRONIC</IfcLabel-wrapper>
							<IfcLabel-wrapper>LOWLOSS</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>RESISTOR</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="LampCompensationType_0oyFy0qUiHuO00025QrE$V" GlobalId="0oyFy0qUiHuO00025QrE$V" Name="LampCompensationType" Description="Identifies the form of compensation used for power factor correction and radio suppression." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_LampCompensationType">
						<EnumerationValues>
							<IfcLabel-wrapper>CAPACITIVE</IfcLabel-wrapper>
							<IfcLabel-wrapper>INDUCTIVE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="LampMaintenanceFactor_0SIgW0qUiHuO00025QrE$V" GlobalId="0SIgW0qUiHuO00025QrE$V" Name="LampMaintenanceFactor" Description="Non recoverable losses of luminous flux of a lamp due to lamp depreciation; i.e. the decreasing of light output of a luminaire due to aging and dirt." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="LandID_1iAMy0qUiHuO00025QrE$V" GlobalId="1iAMy0qUiHuO00025QrE$V" Name="LandID" Description="Identification number assigned by the statutory registration authority to a land parcel." TemplateType="p_singlevalue" PrimaryMeasureType="IfcIdentifier" />
				<IfcSimplePropertyTemplate id="LandTitleID_1x4260qUiHuO00025QrE$V" GlobalId="1x4260qUiHuO00025QrE$V" Name="LandTitleID" Description="Identification number assigned by the statutory registration authority to the title to a land parcel." TemplateType="p_singlevalue" PrimaryMeasureType="IfcIdentifier" />
				<IfcSimplePropertyTemplate id="LaneMeters_1wIXrPLuDA1BAKRB9T3fjR" GlobalId="1wIXrPLuDA1BAKRB9T3fjR" Name="LaneMeters" Description="Length of lanes accommodating vehicles on roll-on, roll-off vessels" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="LaneWidth_0YC67HdNT54ulouz_nXO0L" GlobalId="0YC67HdNT54ulouz_nXO0L" Name="LaneWidth" Description="Standard nominal width of one trough lane." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="LastAssessmentReport_1gG02PahnF2fsfAbELSVmv" GlobalId="1gG02PahnF2fsfAbELSVmv" Name="LastAssessmentReport" Description="Reference to latest condition (state of health) report." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="LatentCoolingCapacity_1rniq0qXCHuO00025QrE$V" GlobalId="1rniq0qXCHuO00025QrE$V" Name="LatentCoolingCapacity" Description="Latent cooling capacity." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="LatentHeatTransferRate_1tit20qS0HuO00025QrE$V" GlobalId="1tit20qS0HuO00025QrE$V" Name="LatentHeatTransferRate" Description="Latent heat transfer rate." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="LatentHeatTransferRate_1YvzI0qU8HuO00025QrE$V" GlobalId="1YvzI0qU8HuO00025QrE$V" Name="LatentHeatTransferRate" Description="Latent heat transfer rate.

To primary air flow." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="Layers_1VMag0qUuHuO00025QrE$V" GlobalId="1VMag0qUuHuO00025QrE$V" Name="Layers" Description="Number of layers." TemplateType="p_singlevalue" PrimaryMeasureType="IfcInteger" />
				<IfcSimplePropertyTemplate id="LayRatio_1LJW3Nv3XFAwnt7PZuIg3n" GlobalId="1LJW3Nv3XFAwnt7PZuIg3n" Name="LayRatio" Description="The ratio between lay length and the diameter of the single conductor." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="Layup_1PP6c0qUuHuO00025QrE$V" GlobalId="1PP6c0qUuHuO00025QrE$V" Name="Layup" Description="Configuration of the lamination." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="LeadInTime_2u_yRtXmj8Re3DPXkTqC9y" GlobalId="2u_yRtXmj8Re3DPXkTqC9y" Name="LeadInTime" Description="Lead in time before start of process." TemplateType="p_singlevalue" PrimaryMeasureType="IfcDuration" />
				<IfcSimplePropertyTemplate id="LeadOutTime_28wkDLvzz6IeIRvXElIFeo" GlobalId="28wkDLvzz6IeIRvXElIFeo" Name="LeadOutTime" Description="Lead out time after end of process." TemplateType="p_singlevalue" PrimaryMeasureType="IfcDuration" />
				<IfcSimplePropertyTemplate id="Leakage_370Pq0qT0HuO00025QrE$V" GlobalId="370Pq0qT0HuO00025QrE$V" Name="Leakage" Description="Air leakage rate." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="LeakageClass_3JYlC0qTeHuO00025QrE$V" GlobalId="3JYlC0qTeHuO00025QrE$V" Name="LeakageClass" Description="Nominal leakage rating for the system components." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="LeakageCurve_1r3KS0qT4HuO00025QrE$V" GlobalId="1r3KS0qT4HuO00025QrE$V" Name="LeakageCurve" Description="Leakage versus pressure drop; Leakage = f (pressure)." TemplateType="p_tablevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" SecondaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="LeakageCurve_24dOU0qVCHuO00025QrE$V" GlobalId="24dOU0qVCHuO00025QrE$V" Name="LeakageCurve" Description="Leakage versus pressure drop; Leakage = f (pressure)." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" />
				<IfcSimplePropertyTemplate id="LeakageCurveHistory_1IpVO0qTuHuO00025QrE$V" GlobalId="1IpVO0qTuHuO00025QrE$V" Name="LeakageCurveHistory" Description="Leakage per unit length curve versus working pressure. If a scalar is expressed then it represents LeakageClass which is flowrate per unit area at a specified pressure rating (e.g., ASHRAE Fundamentals 2001 34.16.)." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" />
				<IfcSimplePropertyTemplate id="LeakageFullyClosed_1dy5W0qT4HuO00025QrE$V" GlobalId="1dy5W0qT4HuO00025QrE$V" Name="LeakageFullyClosed" Description="Leakage when fully closed." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="LeftFlangeWidth_1mMee0qVKHuO00025QrE$V" GlobalId="1mMee0qVKHuO00025QrE$V" Name="LeftFlangeWidth" Description="Left flange width of the profile." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="Legend_3R5x_0qWqHuO00025QrE$V" GlobalId="3R5x_0qWqHuO00025QrE$V" Name="Legend" Description="A text inscribed or applied to the switch as a legend to indicate purpose or function." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="Length_1vU7rvwzz399ndMv3e5Cw7" GlobalId="1vU7rvwzz399ndMv3e5Cw7" Name="Length" Description="The length of the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="Length_20D9S0qX8HuO00025QrE$V" GlobalId="20D9S0qX8HuO00025QrE$V" Name="Length" Description="The length of the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="Length_3WM1Y0qTCHuO00025QrE$V" GlobalId="3WM1Y0qTCHuO00025QrE$V" Name="Length" Description="The length of the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="Length_3XN6g0qX8HuO00025QrE$V" GlobalId="3XN6g0qX8HuO00025QrE$V" Name="Length" Description="The length of the object.

As measured parallel to the direction of airflow." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="LengthBetweenPerpendiculars_049V7LE0rEtgYKr9j$$ZjS" GlobalId="049V7LE0rEtgYKr9j$$ZjS" Name="LengthBetweenPerpendiculars" Description="Length of vessel from rudder shaft to crossing point of the bow and the loaded waterline." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="LengthEmbedmentInRock_0KVr_JgdTCmvMy0tfADhco" GlobalId="0KVr_JgdTCmvMy0tfADhco" Name="LengthEmbedmentInRock" Description="Embedment in rock." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="LengthEmbedmentInRock_1BHl2y49PD_ggO8$9sd9df" GlobalId="1BHl2y49PD_ggO8$9sd9df" Name="LengthEmbedmentInRock" Description="Embedment in rock." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="LengthGroutBody_1l1T$n9HP2kxZocCToc2NI" GlobalId="1l1T$n9HP2kxZocCToc2NI" Name="LengthGroutBody" Description="Length of grout body." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="LengthMeasureResolution_1oWya9l0P0zADha8jVgnSi" GlobalId="1oWya9l0P0zADha8jVgnSi" Name="LengthMeasureResolution" Description="Indicates the resolution for length measure of the device." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="LensDiffuserOrientation_17lLkbAkr2TPS5BNTPqqUI" GlobalId="17lLkbAkr2TPS5BNTPqqUI" Name="LensDiffuserOrientation" Description="Orientation the lens diffuser has to have, which indicates the direction of the lens diffuser and is given in terms like &quot;left upper quadrant (LUQ)&quot; or &quot;5 o&apos;clock&quot;." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="LensDiffuserType_0HtZMlqZj0fx$DPfT30e_r" GlobalId="0HtZMlqZj0fx$DPfT30e_r" Name="LensDiffuserType" Description="Type of the lens diffuser the signal is equipped with." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="LevelOfIntensity_2slUGIunH3dByQMgke_Zq_" GlobalId="2slUGIunH3dByQMgke_Zq_" Name="LevelOfIntensity" Description="An expression of the magnitude or the intensity of a phenomenon." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="LifeCyclePhase_2MTYy0qU4HuO00025QrE$V" GlobalId="2MTYy0qU4HuO00025QrE$V" Name="LifeCyclePhase" Description="The whole life cycle or only a given phase from which environmental data are valid." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_LifeCyclePhase">
						<EnumerationValues>
							<IfcLabel-wrapper>ACQUISITION</IfcLabel-wrapper>
							<IfcLabel-wrapper>CRADLETOSITE</IfcLabel-wrapper>
							<IfcLabel-wrapper>DECONSTRUCTION</IfcLabel-wrapper>
							<IfcLabel-wrapper>DISPOSAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>DISPOSALTRANSPORT</IfcLabel-wrapper>
							<IfcLabel-wrapper>GROWTH</IfcLabel-wrapper>
							<IfcLabel-wrapper>INSTALLATION</IfcLabel-wrapper>
							<IfcLabel-wrapper>MAINTENANCE</IfcLabel-wrapper>
							<IfcLabel-wrapper>MANUFACTURE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OCCUPANCY</IfcLabel-wrapper>
							<IfcLabel-wrapper>OPERATION</IfcLabel-wrapper>
							<IfcLabel-wrapper>PROCUREMENT</IfcLabel-wrapper>
							<IfcLabel-wrapper>PRODUCTION</IfcLabel-wrapper>
							<IfcLabel-wrapper>PRODUCTIONTRANSPORT</IfcLabel-wrapper>
							<IfcLabel-wrapper>RECOVERY</IfcLabel-wrapper>
							<IfcLabel-wrapper>REFURBISHMENT</IfcLabel-wrapper>
							<IfcLabel-wrapper>REPAIR</IfcLabel-wrapper>
							<IfcLabel-wrapper>REPLACEMENT</IfcLabel-wrapper>
							<IfcLabel-wrapper>TRANSPORT</IfcLabel-wrapper>
							<IfcLabel-wrapper>USAGE</IfcLabel-wrapper>
							<IfcLabel-wrapper>WASTE</IfcLabel-wrapper>
							<IfcLabel-wrapper>WHOLELIFECYCLE</IfcLabel-wrapper>
							<IfcLabel-wrapper>USERDEFINED</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTDEFINED</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="LiftElevationDifference_3RaMM0qSyHuO00025QrE$V" GlobalId="3RaMM0qSyHuO00025QrE$V" Name="LiftElevationDifference" Description="Elevation difference between cooling tower sump and the top of the tower." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="LiftingStrength_31jac0qVGHuO00025QrE$V" GlobalId="31jac0qVGHuO00025QrE$V" Name="LiftingStrength" Description="The minimum required compressive strength of the concrete when the concrete element is lifted." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="LightEmitterNominalPower_0Ll320qUiHuO00025QrE$V" GlobalId="0Ll320qUiHuO00025QrE$V" Name="LightEmitterNominalPower" Description="Light emitter nominal power." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="LightFixtureMountingType_2lWzs0qUiHuO00025QrE$V" GlobalId="2lWzs0qUiHuO00025QrE$V" Name="LightFixtureMountingType" Description="A list of the available types of mounting for light fixtures from which that required may be selected." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_LightFixtureMountingType">
						<EnumerationValues>
							<IfcLabel-wrapper>CABLESPANNED</IfcLabel-wrapper>
							<IfcLabel-wrapper>FREESTANDING</IfcLabel-wrapper>
							<IfcLabel-wrapper>POLE_SIDE</IfcLabel-wrapper>
							<IfcLabel-wrapper>POLE_TOP</IfcLabel-wrapper>
							<IfcLabel-wrapper>RECESSED</IfcLabel-wrapper>
							<IfcLabel-wrapper>SURFACE</IfcLabel-wrapper>
							<IfcLabel-wrapper>SUSPENDED</IfcLabel-wrapper>
							<IfcLabel-wrapper>TRACKMOUNTED</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="LightFixturePlacingType_35aPu0qUiHuO00025QrE$V" GlobalId="35aPu0qUiHuO00025QrE$V" Name="LightFixturePlacingType" Description="A list of the available types of placing specification for light fixtures from which that required may be selected." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_LightFixturePlacingType">
						<EnumerationValues>
							<IfcLabel-wrapper>CEILING</IfcLabel-wrapper>
							<IfcLabel-wrapper>FLOOR</IfcLabel-wrapper>
							<IfcLabel-wrapper>FURNITURE</IfcLabel-wrapper>
							<IfcLabel-wrapper>POLE</IfcLabel-wrapper>
							<IfcLabel-wrapper>WALL</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Lighting_1qaQ80qWiHuO00025QrE$V" GlobalId="1qaQ80qWiHuO00025QrE$V" Name="Lighting" Description="Lighting loads." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="LightingDiversity_0Wh9m0qRuHuO00025QrE$V" GlobalId="0Wh9m0qRuHuO00025QrE$V" Name="LightingDiversity" Description="Lighting diversity." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="LightingDiversity_3gvDC0qX0HuO00025QrE$V" GlobalId="3gvDC0qX0HuO00025QrE$V" Name="LightingDiversity" Description="Lighting diversity." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="LightingHistory_3whUY0qWiHuO00025QrE$V" GlobalId="3whUY0qWiHuO00025QrE$V" Name="LightingHistory" Description="Lighting loads." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="LightingLoadIntensity_0nEZ80qX4HuO00025QrE$V" GlobalId="0nEZ80qX4HuO00025QrE$V" Name="LightingLoadIntensity" Description="Average lighting load intensity in the space per unit area (PowerMeasure/IfcAreaMeasure)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcHeatFluxDensityMeasure" />
				<IfcSimplePropertyTemplate id="LightingPercentLoadToReturnAir_0toAc0qX4HuO00025QrE$V" GlobalId="0toAc0qX4HuO00025QrE$V" Name="LightingPercentLoadToReturnAir" Description="Percent of lighting load to the return air plenum." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="LightningPeakVoltage_1UDgFBVIXA9OYX1_nAvy5o" GlobalId="1UDgFBVIXA9OYX1_nAvy5o" Name="LightningPeakVoltage" Description="The peak lightning voltage that the insulator could withstand." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricVoltageMeasure" />
				<IfcSimplePropertyTemplate id="LightningProtectionStandardsCompliance_1nPkqapDrE3gFjVeVrNyIv" GlobalId="1nPkqapDrE3gFjVeVrNyIv" Name="LightningProtectionStandardsCompliance" Description="Information about compliance with regard to lightning protection related standards." TemplateType="p_tablevalue" PrimaryMeasureType="IfcLabel" SecondaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="LikelihoodOfOccurence_2o2ITB5d9B5fr3psKiYy0J" GlobalId="2o2ITB5d9B5fr3psKiYy0J" Name="LikelihoodOfOccurence" Description="Likelihood is a general concept relating to the chance of an event occuring." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="Limitations_0wl2LrL0b7mR5ua2A1tgcx" GlobalId="0wl2LrL0b7mR5ua2A1tgcx" Name="Limitations" Description="Limitations on usage." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="LimitedClearances_1TH9KclvbAF8FOnAfemrVO" GlobalId="1TH9KclvbAF8FOnAfemrVO" Name="LimitedClearances" Description="Special conditions for placing the signal post telephone: tunnels, bridges, viaducts." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="LimitingTerminalSize_0vEwS0qVmHuO00025QrE$V" GlobalId="0vEwS0qVmHuO00025QrE$V" Name="LimitingTerminalSize" Description="The maximum terminal size capacity of the device." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAreaMeasure" />
				<IfcSimplePropertyTemplate id="LinearPath_1Pz9ucT1f6ex16eSfaPgQ$" GlobalId="1Pz9ucT1f6ex16eSfaPgQ$" Name="LinearPath" Description="Represents the time:distance table of the kinematic behaviour." TemplateType="p_tablevalue" PrimaryMeasureType="IfcTimeMeasure" SecondaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="LinearRange_2LCLSUKZH99hoSPDQYRgwF" GlobalId="2LCLSUKZH99hoSPDQYRgwF" Name="LinearRange" Description="Identifies the linear range of the kinematic behaviour." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="LinearUncertainty_0sq832INvCxuwUFe2_4EmP" GlobalId="0sq832INvCxuwUFe2_4EmP" Name="LinearUncertainty" Description="Indicative (95%-100%) range diameter associated to the overall shape and position in XYZ." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="LinearVelocityResolution_3QpbSfACX5DheiB5PkB6kH" GlobalId="3QpbSfACX5DheiB5PkB6kH" Name="LinearVelocityResolution" Description="Indicates the resolution of the detected linear velocity." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLinearVelocityMeasure" />
				<IfcSimplePropertyTemplate id="LineationType_133IV34718eB2pTloYu4BE" GlobalId="133IV34718eB2pTloYu4BE" Name="LineationType" Description="Flow lines, scratches, striae, slickenlines, linear arrangements of elongate components in sediments, elongate minerals, crinkles, and lines of intersection between penetrative planar structures." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="LineCharacteristic_3_0m4qnAT5ZOLLtwRg$XmV" GlobalId="3_0m4qnAT5ZOLLtwRg$XmV" Name="LineCharacteristic" Description="Indicates the characteristic of the line." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_LineCharacteristic">
						<EnumerationValues>
							<IfcLabel-wrapper>PASSENGER</IfcLabel-wrapper>
							<IfcLabel-wrapper>FREIGHT</IfcLabel-wrapper>
							<IfcLabel-wrapper>ENTERDEPOT</IfcLabel-wrapper>
							<IfcLabel-wrapper>PASSENGERANDFREIGHT</IfcLabel-wrapper>
							<IfcLabel-wrapper>EXITDEPOT</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="LineID_1LQ0XPbITCVe8zQJfs9vuz" GlobalId="1LQ0XPbITCVe8zQJfs9vuz" Name="LineID" Description="The unique identifier of the line." TemplateType="p_singlevalue" PrimaryMeasureType="IfcIdentifier" />
				<IfcSimplePropertyTemplate id="LineIdentifier_1PYHABAEb2ZBJGSxWcsNYh" GlobalId="1PYHABAEb2ZBJGSxWcsNYh" Name="LineIdentifier" Description="Reference ID relative to a design vessel in the project" TemplateType="p_singlevalue" PrimaryMeasureType="IfcIdentifier" />
				<IfcSimplePropertyTemplate id="LineStrength_0htP3VyZ94$vpry8cecGEh" GlobalId="0htP3VyZ94$vpry8cecGEh" Name="LineStrength" Description="Breaking load of the line (note that ultimate stress is not part of any of the material Psets)" TemplateType="p_singlevalue" PrimaryMeasureType="IfcForceMeasure" />
				<IfcSimplePropertyTemplate id="LineType_2fAOC7skD9Fgvn3zk5Z1Ey" GlobalId="2fAOC7skD9Fgvn3zk5Z1Ey" Name="LineType" Description="Mooring line type" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="LiningDepth_1atVjJ$Sv83QJrcnVw6dEN" GlobalId="1atVjJ$Sv83QJrcnVw6dEN" Name="LiningDepth" Description="The depth of the lining.

For a window, it is the depth of the window lining, measured perpendicularly to window elevation plane." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="LiningDepth_1G_SQtW4j5pxKrrTsULYJ5" GlobalId="1G_SQtW4j5pxKrrTsULYJ5" Name="LiningDepth" Description="The depth of the lining.

For a door, it is the depth of the door lining, measured perpendicular to the plane of the door lining. If omitted (and with a given value to lining thickness) it indicates an adjustable depth (i.e. a depth that adjusts to the thickness of the wall into which the occurrence of this door style is inserted)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="LiningMaterial_0mAA1gW8z7mevSgdceBIp5" GlobalId="0mAA1gW8z7mevSgdceBIp5" Name="LiningMaterial" Description="The material of the lining for borehole wall stabilizing." TemplateType="p_referencevalue" PrimaryMeasureType="IfcMaterialDefinition" SecondaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="LiningMaterial_1McGbPCCv3Hhv0UCetKMD7" GlobalId="1McGbPCCv3Hhv0UCetKMD7" Name="LiningMaterial" Description="Lining material or &apos;NOT LINED&apos; or &apos;UNKNOWN&apos; (boreholeML)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="LiningOffset_043uIBEdfCSBmgT2Iqxz1k" GlobalId="043uIBEdfCSBmgT2Iqxz1k" Name="LiningOffset" Description="Offset of the lining.

For a window, it is the offset of the window lining, given as distance along the y axis of the local placement (perpendicular to the window plane)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="LiningOffset_1cgphqjyn8jguBS5oJGpbV" GlobalId="1cgphqjyn8jguBS5oJGpbV" Name="LiningOffset" Description="Offset of the lining.

For a door, it is the offset (dimension in plane perpendicular to door leaf) of the door lining. The offset is given as distance to the x axis of the local placement." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="LiningThickness_0ZvUzLlUn9gwgkgGSHJ0wI" GlobalId="0ZvUzLlUn9gwgkgGSHJ0wI" Name="LiningThickness" Description="Thickness of the lining." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="LiningThickness_2BYAcFEujALBCPBrRERjlx" GlobalId="2BYAcFEujALBCPBrRERjlx" Name="LiningThickness" Description="Thickness of the lining.

For a door, it is the thickness of the door lining as explained in the figure above. If LiningThickness value is 0. (zero) it denotes a door without a lining (all other lining parameters shall be set to NIL in this case). If the LiningThickness is NIL it denotes that the value is not available." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNonNegativeLengthMeasure" />
				<IfcSimplePropertyTemplate id="LiningThickness_2F6K$8L5H9ffpQ$GwVOHM9" GlobalId="2F6K$8L5H9ffpQ$GwVOHM9" Name="LiningThickness" Description="Thickness of the lining.

For a window, it is the thickness of the window lining as explained in the figure below. If LiningThickness value is 0. (zero) it denotes a window without a lining (all other lining parameters shall be set to NIL in this case). If the LiningThickness is NIL it denotes that the value is not available." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNonNegativeLengthMeasure" />
				<IfcSimplePropertyTemplate id="LiningToPanelOffsetX_0hdVnTz9j3fRec1g0eGhK2" GlobalId="0hdVnTz9j3fRec1g0eGhK2" Name="LiningToPanelOffsetX" Description="Offset between the lining and the panel, measured along the x-axis of the local placement.

For a door, it is the offset between the lining and the window panel." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="LiningToPanelOffsetX_2qOaLgNMvDYAhH_qO9ORRY" GlobalId="2qOaLgNMvDYAhH_qO9ORRY" Name="LiningToPanelOffsetX" Description="Offset between the lining and the panel, measured along the x-axis of the local placement.

For a window, it is the offset between the lining and the window panel. Should be smaller or equal to the LiningThickness." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="LiningToPanelOffsetY_1pT3EEArz94xz7MrzElsni" GlobalId="1pT3EEArz94xz7MrzElsni" Name="LiningToPanelOffsetY" Description="Offset between the lining and the panel, measured along the y-axis of the local placement.

For a door, it is the offset between the lining and the door panel." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="LiningToPanelOffsetY_1ROGiXiRP7GRCBWrJKxDo1" GlobalId="1ROGiXiRP7GRCBWrJKxDo1" Name="LiningToPanelOffsetY" Description="Offset between the lining and the panel, measured along the y-axis of the local placement.

For a window, it is the offset between the lining and the window panel. Should be smaller or equal to the IfcWindowPanelProperties.PanelThickness." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="LiquidLimits_2AHK69qTTB1htxysz9ebsl" GlobalId="2AHK69qTTB1htxysz9ebsl" Name="LiquidLimits" Description="The water content in percent where the soil starts to behave as a liquid.
&gt; NOTE&amp;nbsp; Definition according to ISO17892." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="Lithology_0LdEScS1D9oRyQIFkXH3yi" GlobalId="0LdEScS1D9oRyQIFkXH3yi" Name="Lithology" Description="Defines all natural materials resulting from the combination of minerals, particles or biogenic elements." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="Lithology_3Ib9wYZlH8rvMKekRGTYia" GlobalId="3Ib9wYZlH8rvMKekRGTYia" Name="Lithology" Description="Defines all natural materials resulting from the combination of minerals, particles or biogenic elements." TemplateType="p_singlevalue" PrimaryMeasureType="IfcIdentifier" />
				<IfcSimplePropertyTemplate id="Load_1ML8E0qSGHuO00025QrE$V" GlobalId="1ML8E0qSGHuO00025QrE$V" Name="Load" Description="Boiler real load." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="LoadBearing_0pmcg0qSGHuO00025QrE$V" GlobalId="0pmcg0qSGHuO00025QrE$V" Name="LoadBearing" Description="Indicates whether the object is intended to carry loads (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="LoadBearing_0UPJI0qVGHuO00025QrE$V" GlobalId="0UPJI0qVGHuO00025QrE$V" Name="LoadBearing" Description="Indicates whether the object is intended to carry loads (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="LoadBearing_0x2sU0qWWHuO00025QrE$V" GlobalId="0x2sU0qWWHuO00025QrE$V" Name="LoadBearing" Description="Indicates whether the object is intended to carry loads (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="LoadBearing_13kNCI9h11aBPeqCQFREYC" GlobalId="13kNCI9h11aBPeqCQFREYC" Name="LoadBearing" Description="Indicates whether the object is intended to carry loads (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="LoadBearing_1cDoRk08vDj9jlUoQLAX$f" GlobalId="1cDoRk08vDj9jlUoQLAX$f" Name="LoadBearing" Description="Indicates whether the object is intended to carry loads (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="LoadBearing_1dKyE0qSaHuO00025QrE$V" GlobalId="1dKyE0qSaHuO00025QrE$V" Name="LoadBearing" Description="Indicates whether the object is intended to carry loads (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="LoadBearing_1EuQe0qSKHuO00025QrE$V" GlobalId="1EuQe0qSKHuO00025QrE$V" Name="LoadBearing" Description="Indicates whether the object is intended to carry loads (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="LoadBearing_1s7fxao7L4X9mgLw5vDLbk" GlobalId="1s7fxao7L4X9mgLw5vDLbk" Name="LoadBearing" Description="Indicates whether the object is intended to carry loads (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="LoadBearing_1wUec0qV4HuO00025QrE$V" GlobalId="1wUec0qV4HuO00025QrE$V" Name="LoadBearing" Description="Indicates whether the object is intended to carry loads (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="LoadBearing_1wZ5bqss58mx9mYZdud_ti" GlobalId="1wZ5bqss58mx9mYZdud_ti" Name="LoadBearing" Description="Indicates whether the object is intended to carry loads (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="LoadBearing_21GTO0qSeHuO00025QrE$V" GlobalId="21GTO0qSeHuO00025QrE$V" Name="LoadBearing" Description="Indicates whether the object is intended to carry loads (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="LoadBearing_27gGzXJgHElgJNKZaas8aH" GlobalId="27gGzXJgHElgJNKZaas8aH" Name="LoadBearing" Description="Indicates whether the object is intended to carry loads (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="LoadBearing_2FnJNsRdfDQ9dzEq8OinWs" GlobalId="2FnJNsRdfDQ9dzEq8OinWs" Name="LoadBearing" Description="Indicates whether the object is intended to carry loads (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="LoadBearing_3nmXI0qXKHuO00025QrE$V" GlobalId="3nmXI0qXKHuO00025QrE$V" Name="LoadBearing" Description="Indicates whether the object is intended to carry loads (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="LoadBearingCapacity_2r2w0IRgj2ZPPZHhlnoADU" GlobalId="2r2w0IRgj2ZPPZHhlnoADU" Name="LoadBearingCapacity" Description="Estimate or design maximum load bearing capacity of the defined surface/structure (e.g. soil stratum or planar slab). Represented as a force per unit area measurement." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="LoadBearingCapacity_2RBEe0qSKHuO00025QrE$V" GlobalId="2RBEe0qSKHuO00025QrE$V" Name="LoadBearingCapacity" Description="Maximum load bearing capacity of the floor structure throughtout the storey as designed." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlanarForceMeasure" />
				<IfcSimplePropertyTemplate id="LoadCapacity_1_J9Z6hsjADva_RGdwfJlg" GlobalId="1_J9Z6hsjADva_RGdwfJlg" Name="LoadCapacity" Description="Indicates the highest permissible load capacity." TemplateType="p_singlevalue" PrimaryMeasureType="IfcForceMeasure" />
				<IfcSimplePropertyTemplate id="LoadDisconnectionType_35xs20qWuHuO00025QrE$V" GlobalId="35xs20qWuHuO00025QrE$V" Name="LoadDisconnectionType" Description="A list of the available types of load disconnection from which that required may be selected." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_LoadDisconnectionType">
						<EnumerationValues>
							<IfcLabel-wrapper>OFFLOAD</IfcLabel-wrapper>
							<IfcLabel-wrapper>ONLOAD</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="LoadSafetyFactor_06Jzu0qX4HuO00025QrE$V" GlobalId="06Jzu0qX4HuO00025QrE$V" Name="LoadSafetyFactor" Description="Load safety factor." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="LocalName_0ebn7wWEP34Ad62PIlPZk7" GlobalId="0ebn7wWEP34Ad62PIlPZk7" Name="LocalName" Description="The local name that the plant is known as." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="Location1Global_0VB5hczAH7CvQQx$j1YIft" GlobalId="0VB5hczAH7CvQQx$j1YIft" Name="Location1Global" Description="Global X,Y,Z coordinates of the point in which Thickness1 is given" TemplateType="p_listvalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="Location1Local_2zGAa4OsLC_vpMJq9V0dK4" GlobalId="2zGAa4OsLC_vpMJq9V0dK4" Name="Location1Local" Description="Local x,y coordinates of the point in which Thickness1 is given" TemplateType="p_listvalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="Location2Global_3F_zLtoAvAuxd7yNYHwBJO" GlobalId="3F_zLtoAvAuxd7yNYHwBJO" Name="Location2Global" Description="Global X,Y,Z coordinates of the point in which Thickness2 is given" TemplateType="p_listvalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="Location2Local_05ZaO2Wmn1z8Oh7HnpEAUm" GlobalId="05ZaO2Wmn1z8Oh7HnpEAUm" Name="Location2Local" Description="Local x,y coordinates of the point in which Thickness2 is given" TemplateType="p_listvalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="Location3Global_2FeT$dKObBQfRWSKCREUA2" GlobalId="2FeT$dKObBQfRWSKCREUA2" Name="Location3Global" Description="Global X,Y,Z coordinates of the point in which Thickness3 is given" TemplateType="p_listvalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="Location3Local_144HUwHt9CFfHkh4JmV3dQ" GlobalId="144HUwHt9CFfHkh4JmV3dQ" Name="Location3Local" Description="Local x,y coordinates of the point in which Thickness3 is given" TemplateType="p_listvalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="LocationPriorityType_2e_sC0qVSHuO00025QrE$V" GlobalId="2e_sC0qVSHuO00025QrE$V" Name="LocationPriorityType" Description="Identifies the predefined types of priority that can be assigned from which the type may be set where:

High: action is required urgently.
Medium: action can occur within a reasonable period of time.
Low: action can occur when convenient." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i1079" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="LockChamberLevels_0vmNm3RpjAFxGZPkc8F$8N" GlobalId="0vmNm3RpjAFxGZPkc8F$8N" Name="LockChamberLevels" Description="Number of steps (chambers) in a lock line" TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="LockedRotorCurrent_3ztwy0qU0HuO00025QrE$V" GlobalId="3ztwy0qU0HuO00025QrE$V" Name="LockedRotorCurrent" Description="Input current when a motor armature is energized but not rotating." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="LockGrade_0afpeKNpXAKuHqMZlEs7GD" GlobalId="0afpeKNpXAKuHqMZlEs7GD" Name="LockGrade" Description="Operational grading of the ship lock complex" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="LockingForce_0pLtPGaujDkwK16bnNbYZE" GlobalId="0pLtPGaujDkwK16bnNbYZE" Name="LockingForce" Description="Locking force of the element." TemplateType="p_singlevalue" PrimaryMeasureType="IfcForceMeasure" />
				<IfcSimplePropertyTemplate id="LockLines_3C7vosE2r9xg8_bdQ0FZvD" GlobalId="3C7vosE2r9xg8_bdQ0FZvD" Name="LockLines" Description="Number of Parallel lock series" TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="LockMode_3FQU_MOXLE7gE5hin075dS" GlobalId="3FQU_MOXLE7gE5hin075dS" Name="LockMode" Description="Type of lock system used." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="LogarithmicMeanTemperatureDifference_1ozBc0qSmHuO00025QrE$V" GlobalId="1ozBc0qSmHuO00025QrE$V" Name="LogarithmicMeanTemperatureDifference" Description="Logarithmic mean temperature difference between refrigerant and water or air." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="LogarithmicMeanTemperatureDifference_3UuXo0qU8HuO00025QrE$V" GlobalId="3UuXo0qU8HuO00025QrE$V" Name="LogarithmicMeanTemperatureDifference" Description="Logarithmic mean temperature difference between refrigerant and water or air." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="LogNumber_2H$tb9GtfCP9DRUp61IODv" GlobalId="2H$tb9GtfCP9DRUp61IODv" Name="LogNumber" Description="Identifer of the records." TemplateType="p_singlevalue" PrimaryMeasureType="IfcInteger" />
				<IfcSimplePropertyTemplate id="LongInsideCenterLowerBarPitch_2DuI40qW0HuO00025QrE$V" GlobalId="2DuI40qW0HuO00025QrE$V" Name="LongInsideCenterLowerBarPitch" Description="The pitch length of the long inside center lower bar." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="LongInsideCenterTopBarPitch_1TcOA0qW0HuO00025QrE$V" GlobalId="1TcOA0qW0HuO00025QrE$V" Name="LongInsideCenterTopBarPitch" Description="The pitch length of the long inside center top bar." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="LongInsideEndLowerBarPitch_2LeCM0qW0HuO00025QrE$V" GlobalId="2LeCM0qW0HuO00025QrE$V" Name="LongInsideEndLowerBarPitch" Description="The pitch length of the long inside end lower bar." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="LongInsideEndTopBarPitch_1byRs0qW0HuO00025QrE$V" GlobalId="1byRs0qW0HuO00025QrE$V" Name="LongInsideEndTopBarPitch" Description="The pitch length of the long inside end top bar." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="LongitudinalConnections_1azFwlJa58zglMh9JjImfr" GlobalId="1azFwlJa58zglMh9JjImfr" Name="LongitudinalConnections" Description="Specifies the type of steel profiles that connect ribs longitudinally." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="LongitudinalInclination_3Z$M_GmZb1svkg1noG1s2m" GlobalId="3Z$M_GmZb1svkg1noG1s2m" Name="LongitudinalInclination" Description="Incination measured vs the cross section plane." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="LongitudinalJointConnections_0euxSzkhDAcfFPu$B$85Tb" GlobalId="0euxSzkhDAcfFPu$B$85Tb" Name="LongitudinalJointConnections" Description="Specified if particular connector, e.g. guiding rod, is used." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="LongitudinalJointType_043Isdhjv28ObjidKJA1er" GlobalId="043Isdhjv28ObjidKJA1er" Name="LongitudinalJointType" Description="Type of longitudinal joint." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" id="i1883" Name="PEnum_SegmentJointType">
						<EnumerationValues>
							<IfcLabel-wrapper>FLAT</IfcLabel-wrapper>
							<IfcLabel-wrapper>TONGUE_GROOVE</IfcLabel-wrapper>
							<IfcLabel-wrapper>CONVEX_CONVEX</IfcLabel-wrapper>
							<IfcLabel-wrapper>CONCAVE_CONVEX</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>USERDEFINED</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="LongitudinalOverlap_28woezad9CpfySfEKH2kbf" GlobalId="28woezad9CpfySfEKH2kbf" Name="LongitudinalOverlap" Description="The overlap between grout holes." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="LongitudinalSeam_2ZHLE0qTuHuO00025QrE$V" GlobalId="2ZHLE0qTuHuO00025QrE$V" Name="LongitudinalSeam" Description="The type of seam to be used along the longitudinal axis of the duct segment." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="LongitudinalSpacing_0dbSQlDqf0gx1Y4PXUaaxd" GlobalId="0dbSQlDqf0gx1Y4PXUaaxd" Name="LongitudinalSpacing" Description="Longitudinal spacing of bolts." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="LongitudinalSpacing_2Fqc$pMNj5C8jRJPnj8nSC" GlobalId="2Fqc$pMNj5C8jRJPnj8nSC" Name="LongitudinalSpacing" Description="Longitudinal spacing between steel ribs." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="LongOutsideLowerBarPitch_25YEO0qW0HuO00025QrE$V" GlobalId="25YEO0qW0HuO00025QrE$V" Name="LongOutsideLowerBarPitch" Description="The pitch length of the long outside lower bar." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="LongOutsideTopBarPitch_1LGKU0qW0HuO00025QrE$V" GlobalId="1LGKU0qW0HuO00025QrE$V" Name="LongOutsideTopBarPitch" Description="The pitch length of the long outside top bar." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="LongTimeCurrentSetValue_1BmzSXNQn2_Aq_1ft2LPxY" GlobalId="1BmzSXNQn2_Aq_1ft2LPxY" Name="LongTimeCurrentSetValue" Description="Long time current set value. The set value of the long time tripping current if adjustable." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="LongTimeDelay_3m9GefCtz3PAoplbsg0gtG" GlobalId="3m9GefCtz3PAoplbsg0gtG" Name="LongTimeDelay" Description="Long time delay. The set value of the long time time-delay if adjustable." TemplateType="p_singlevalue" PrimaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="LongTimeFunction_3v9GlTSDzClwzgroqc5m82" GlobalId="3v9GlTSDzClwzgroqc5m82" Name="LongTimeFunction" Description="Applying long time function
A flag indicating that the long time function (i.e. the thermal tripping) of the device is used. The value should be set to TRUE for all devices except those that allows the Long time function of the device not to be used." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="LossCoefficentCurve_1ijGm0qT4HuO00025QrE$V" GlobalId="1ijGm0qT4HuO00025QrE$V" Name="LossCoefficentCurve" Description="Loss coefficient – blade position angle curve; ratio of pressure drop to velocity pressure versus blade angle; C = f (blade angle position)." TemplateType="p_tablevalue" PrimaryMeasureType="IfcPositivePlaneAngleMeasure" SecondaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="LossCoefficient_1BfkW0qTuHuO00025QrE$V" GlobalId="1BfkW0qTuHuO00025QrE$V" Name="LossCoefficient" Description="Dimensionless loss coefficient used for calculating fluid resistance representing the ratio of total pressure loss to velocity pressure at a referenced cross-section." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="LossCoefficient_3sQjQ0qTqHuO00025QrE$V" GlobalId="3sQjQ0qTqHuO00025QrE$V" Name="LossCoefficient" Description="Dimensionless loss coefficient used for calculating fluid resistance representing the ratio of total pressure loss to velocity pressure at a referenced cross-section." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="LossCoefficient_3UKO80qV8HuO00025QrE$V" GlobalId="3UKO80qV8HuO00025QrE$V" Name="LossCoefficient" Description="Dimensionless loss coefficient used for calculating fluid resistance representing the ratio of total pressure loss to velocity pressure at a referenced cross-section." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="LowerCurrent1_0dfS_0qViHuO00025QrE$V" GlobalId="0dfS_0qViHuO00025QrE$V" Name="LowerCurrent1" Description="The current in [x In], indicating that for currents smaller than LowerCurrent1 the I2t part of the L-function will not trip the current," TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="LowerCurrent2_0kpDs0qViHuO00025QrE$V" GlobalId="0kpDs0qViHuO00025QrE$V" Name="LowerCurrent2" Description="The current in [x In], indicating the upper current limit of the lower time/current curve of the I2t part of the L-function." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="LowerHeatingValue_1ACEm0qUqHuO00025QrE$V" GlobalId="1ACEm0qUqHuO00025QrE$V" Name="LowerHeatingValue" Description="Lower Heating Value is defined as the amount of energy released (MJ/kg) when a fuel is burned completely, and H2O is in vapor form in the combustion products." TemplateType="p_singlevalue" PrimaryMeasureType="IfcHeatingValueMeasure" />
				<IfcSimplePropertyTemplate id="LowerTime1_0qmhw0qViHuO00025QrE$V" GlobalId="0qmhw0qViHuO00025QrE$V" Name="LowerTime1" Description="The time in [s], indicating that tripping times of the lower time/current curve lower than LowerTime1 is determined by the I2t part of the L-function." TemplateType="p_singlevalue" PrimaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="LowerTime2_0vXtA0qViHuO00025QrE$V" GlobalId="0vXtA0qViHuO00025QrE$V" Name="LowerTime2" Description="The time in [s], indicating the tripping times of the upper time/current curve at the LowerCurrent2." TemplateType="p_singlevalue" PrimaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="LowerVaporResistanceFactor_1Tt5A0qUqHuO00025QrE$V" GlobalId="1Tt5A0qUqHuO00025QrE$V" Name="LowerVaporResistanceFactor" Description="The vapor permeability relationship of air/material (typically value &gt; 1), measured in low relative humidity (typically in 0/50 % RH)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="LowestSeatingHeight_3W5aW0qUWHuO00025QrE$V" GlobalId="3W5aW0qUWHuO00025QrE$V" Name="LowestSeatingHeight" Description="The value of seating height of low level if the chair height is adjustable." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="LowWaterLevel_2CX_WFHkv9vByq2fOmXUgW" GlobalId="2CX_WFHkv9vByq2fOmXUgW" Name="LowWaterLevel" Description="Low water level" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="LRMConstraint_2xXz1khr17N8VXs3Y3yIkv" GlobalId="2xXz1khr17N8VXs3Y3yIkv" Name="LRMConstraint" Description="Allows for the specification of constraints imposed by this Linear Referencing Method. For example, a Reference Post Linear Referencing Method may specify that referents be of type “reference marker”.

&gt; NOTE&amp;nbsp;definition according to ISO 19148:2021" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="LRMName_0s7OWAZj9Dahx00TGDv8Mp" GlobalId="0s7OWAZj9Dahx00TGDv8Mp" Name="LRMName" Description="Gives the name of this Linear Referencing Method, such as “kilometre-point”. 

&gt; NOTE&amp;nbsp;Definition according to ISO 19148:2021.
&gt;
&gt; NOTE&amp;nbsp;Names of commonly used Linear Referencing Methods are included in ISO 19148, Annex C, along with recognized name aliases." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="LRMType_3gFkmWZM9F69385xEVB7Qv" GlobalId="3gFkmWZM9F69385xEVB7Qv" Name="LRMType" Description="Gives the type of this Linear Referencing Method.

&gt; NOTE&amp;nbsp;Definition according to ISO 19148:2021, LRMType.

&gt; NOTE&amp;nbsp;Since the definition in ISO 19148:2021, LRMType is stereotyped as a CodeList it is open for user defined extensions. In this Pset this is handled by adding the enumeration constant _LRM_USERDEFINED_ and the additional property _UserDefinedLRMType_" TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_LRMType">
						<EnumerationValues>
							<IfcLabel-wrapper>LRM_ABSOLUTE</IfcLabel-wrapper>
							<IfcLabel-wrapper>LRM_RELATIVE</IfcLabel-wrapper>
							<IfcLabel-wrapper>LRM_INTERPOLATIVE</IfcLabel-wrapper>
							<IfcLabel-wrapper>LRM_USERDEFINED</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="LRMUnit_3hWrEPG6TBow7MJYMO7xCA" GlobalId="3hWrEPG6TBow7MJYMO7xCA" Name="LRMUnit" Description="Specifies the units of measure used by this Linear Referencing Method for measures along the linear element being measured.

&gt; NOTE&amp;nbsp;Definition according to ISO 19148:2021." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="LubricantPumpHeatGain_3y2l40qSeHuO00025QrE$V" GlobalId="3y2l40qSeHuO00025QrE$V" Name="LubricantPumpHeatGain" Description="Lubricant pump heat gain." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="LubricationPowerSupplyType_27I6bQ4Fj9NA8AgikwDk3z" GlobalId="27I6bQ4Fj9NA8AgikwDk3z" Name="LubricationPowerSupplyType" Description="Type of power supply method used by the rail lubrication." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_LubricationPowerSupply">
						<EnumerationValues>
							<IfcLabel-wrapper>ELECTRIC</IfcLabel-wrapper>
							<IfcLabel-wrapper>PHOTOVOLTAIC</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="LubricationSystemType_2aGJLDX7bAguqlV$JHtrbv" GlobalId="2aGJLDX7bAguqlV$JHtrbv" Name="LubricationSystemType" Description="Design and type of lubricating system e.g. active, passive." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_LubricationSystemType">
						<EnumerationValues>
							<IfcLabel-wrapper>ACTIVE_LUBRICATION</IfcLabel-wrapper>
							<IfcLabel-wrapper>PASSIVE_LUBRICATION</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="LugeonValue_1Vq$ixlprFEfLHBz9MYvS3" GlobalId="1Vq$ixlprFEfLHBz9MYvS3" Name="LugeonValue" Description="Lugeon Value = (q / L) x (P0 / P), where: 
- q: flow rate [lit/min] 
- L: Length of the borehole test interval [m] 
- P0: reference pressure of 1 MPa [MPa] 
- P: Test pressure [MPa]" TemplateType="p_listvalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="MainColour_0Pvqw0qUaHuO00025QrE$V" GlobalId="0Pvqw0qUaHuO00025QrE$V" Name="MainColour" Description="The main colour of the furniture of this type." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="MaintenanceDowntime_18YJqf1cHB_AgALw4trjcf" GlobalId="18YJqf1cHB_AgALw4trjcf" Name="MaintenanceDowntime" Description="Maintenance downtime proportion." TemplateType="p_singlevalue" PrimaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="MaintenanceFactor_3O2zU0qUiHuO00025QrE$V" GlobalId="3O2zU0qUiHuO00025QrE$V" Name="MaintenanceFactor" Description="The arithmetical allowance made for depreciation of lamps and reflective equipment from their initial values due to dirt, fumes, or age." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="MaintenanceLevel_2Nvr9q12L4g9osMugKTcqm" GlobalId="2Nvr9q12L4g9osMugKTcqm" Name="MaintenanceLevel" Description="Adjustment of the service life resulting from the effect of the level or degree of maintenance applied to dcomponents." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="MaintenanceType_1u6ou0qVSHuO00025QrE$V" GlobalId="1u6ou0qVSHuO00025QrE$V" Name="MaintenanceType" Description="Identifies the predefined types of maintenance that can be done from which the type that generates the maintenance work order may be set where:

ConditionBased: generated as a result of the condition of an asset or artefact being less than a determined value.
Corrective: generated as a result of an immediate and urgent need for maintenance action.
PlannedCorrective: generated as a result of immediate corrective action being needed but with sufficient time available for the work order to be included in maintenance planning.
Scheduled: generated as a result of a fixed, periodic maintenance requirement." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_MaintenanceType">
						<EnumerationValues>
							<IfcLabel-wrapper>CONDITIONBASED</IfcLabel-wrapper>
							<IfcLabel-wrapper>CORRECTIVE</IfcLabel-wrapper>
							<IfcLabel-wrapper>PLANNEDCORRECTIVE</IfcLabel-wrapper>
							<IfcLabel-wrapper>SCHEDULED</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ManagingSoftware_3aRmeqOcHEwhPmdUx1o9wR" GlobalId="3aRmeqOcHEwhPmdUx1o9wR" Name="ManagingSoftware" Description="Indicates the type of software responsible for managing the equipment." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ManchetteSpacing_2kV4pAMCT6lgzNH8KhgyOL" GlobalId="2kV4pAMCT6lgzNH8KhgyOL" Name="ManchetteSpacing" Description="Spacing between the manchettes." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ManualOverride_1Dh7y0qRqHuO00025QrE$V" GlobalId="1Dh7y0qRqHuO00025QrE$V" Name="ManualOverride" Description="Identifies whether hand-operated operation is provided as an override (= TRUE) or not (= FALSE). Note that this value should be set to FALSE by default in the case of a Hand Operated Actuator." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="Manufacturer_2Icze0qUmHuO00025QrE$V" GlobalId="2Icze0qUmHuO00025QrE$V" Name="Manufacturer" Description="The organization that manufactured and/or assembled the item." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ManufacturingDate_1$Jp6hK45Bou8c2TZpfomg" GlobalId="1$Jp6hK45Bou8c2TZpfomg" Name="ManufacturingDate" Description="Date on which the element was manufactured." TemplateType="p_singlevalue" PrimaryMeasureType="IfcDate" />
				<IfcSimplePropertyTemplate id="ManufacturingTechnology_3184bedm1EBOAi0U5_PkrQ" GlobalId="3184bedm1EBOAi0U5_PkrQ" Name="ManufacturingTechnology" Description="The method / technology used to produce the equipment." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ManufacturingToleranceClass_2qcLg0qVGHuO00025QrE$V" GlobalId="2qcLg0qVGHuO00025QrE$V" Name="ManufacturingToleranceClass" Description="Classification designation of the manufacturing tolerances according to local standards." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="MarginOfError_0s_xrUcWT9f8dYGpX5qVTI" GlobalId="0s_xrUcWT9f8dYGpX5qVTI" Name="MarginOfError" Description="Indicates the margin of error of the measurement." TemplateType="p_singlevalue" PrimaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="MarkerType_2evuRsoi54$u$eV2ZYT$P_" GlobalId="2evuRsoi54$u$eV2ZYT$P_" Name="MarkerType" Description="The type of marker (sign) e.g. stop signal, restriction signal, track circuit tuning zone sign or others specified in _PEnum_MarkerType_." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_MarkerType">
						<EnumerationValues>
							<IfcLabel-wrapper>STOP_SIGN</IfcLabel-wrapper>
							<IfcLabel-wrapper>RESTRICTION_SIGN</IfcLabel-wrapper>
							<IfcLabel-wrapper>RESTRICTION_PROTECTION_AREA_TERMINAL_SIGN</IfcLabel-wrapper>
							<IfcLabel-wrapper>FOUR_ASPECT_CAB_SIGNAL_CONNECT_SIGN</IfcLabel-wrapper>
							<IfcLabel-wrapper>FOUR_ASPECT_CAB_SIGNAL_DISCONNECT_SIGN</IfcLabel-wrapper>
							<IfcLabel-wrapper>TRACK_CIRCUIT_TUNING_ZONE_SIGN</IfcLabel-wrapper>
							<IfcLabel-wrapper>RESTRICTION_PLACE_SIGN</IfcLabel-wrapper>
							<IfcLabel-wrapper>LOCOMOTIVE_STOP_POSITION_SIGN</IfcLabel-wrapper>
							<IfcLabel-wrapper>EMU_STOP_POSITION_SIGN</IfcLabel-wrapper>
							<IfcLabel-wrapper>RELAY_STATION_SIGN</IfcLabel-wrapper>
							<IfcLabel-wrapper>SECTION_SIGNAL_MARKER</IfcLabel-wrapper>
							<IfcLabel-wrapper>LEVEL_CONVERSION_SIGN</IfcLabel-wrapper>
							<IfcLabel-wrapper>COMMUNICATION_MODE_CONVERSION_MARKER</IfcLabel-wrapper>
							<IfcLabel-wrapper>CABLE_POST_MARKER</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
							<IfcLabel-wrapper>APPROACHING_MARKER</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="MarketCategory_0BEt00qSOHuO00025QrE$V" GlobalId="0BEt00qSOHuO00025QrE$V" Name="MarketCategory" Description="Category of use e.g. residential, commercial, recreation etc." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="MarketCategory_2z9co0qSKHuO00025QrE$V" GlobalId="2z9co0qSKHuO00025QrE$V" Name="MarketCategory" Description="Category of use e.g. residential, commercial, recreation etc." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="MarketSubCategoriesAvailableFuture_3sztC0qSKHuO00025QrE$V" GlobalId="3sztC0qSKHuO00025QrE$V" Name="MarketSubCategoriesAvailableFuture" Description="A list of the sub categories of property that are expected to be available in the future expressed in terms of IfcLabel." TemplateType="p_listvalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="MarketSubCategoriesAvailableNow_3Vk8M0qSKHuO00025QrE$V" GlobalId="3Vk8M0qSKHuO00025QrE$V" Name="MarketSubCategoriesAvailableNow" Description="A list of the sub categories of property that are currently available expressed in terms of IfcLabel." TemplateType="p_listvalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="MarketSubCategory_0GcBg0qSOHuO00025QrE$V" GlobalId="0GcBg0qSOHuO00025QrE$V" Name="MarketSubCategory" Description="Subset of category of use e.g. multi-family, 2 bedroom, low rise." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="MarketSubCategory_3374s0qSKHuO00025QrE$V" GlobalId="3374s0qSKHuO00025QrE$V" Name="MarketSubCategory" Description="Subset of category of use e.g. multi-family, 2 bedroom, low rise." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="MarkingRodMovementLength_0yycL4CG92IuVgPQIqAk$Z" GlobalId="0yycL4CG92IuVgPQIqAk$Z" Name="MarkingRodMovementLength" Description="The length of the movement bar which indicates the turnout position." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="MassDensity_3TjUq0qUmHuO00025QrE$V" GlobalId="3TjUq0qUmHuO00025QrE$V" Name="MassDensity" Description="Material mass density." TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassDensityMeasure" />
				<IfcSimplePropertyTemplate id="MassFlowRate_2ZstQG09z2gOYfzMWxAUkF" GlobalId="2ZstQG09z2gOYfzMWxAUkF" Name="MassFlowRate" Description="The mass flow rate of the fluid." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcMassFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="MassFlowRateHistory_2_Ce9CHon4wAjnpmQnq8Z9" GlobalId="2_Ce9CHon4wAjnpmQnq8Z9" Name="MassFlowRateHistory" Description="The mass flow rate of the fluid." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcMassFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="MassPerLength_1bxC00qVOHuO00025QrE$V" GlobalId="1bxC00qVOHuO00025QrE$V" Name="MassPerLength" Description="Mass per length, i.e. mass of a beam with a unit length of extrusion. For example measured in kg/m." TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassPerLengthMeasure" />
				<IfcSimplePropertyTemplate id="MasterUnitType_0QeUyL0pf4MOJiDslA49ZJ" GlobalId="0QeUyL0pf4MOJiDslA49ZJ" Name="MasterUnitType" Description="Indicates the master unit type." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_MasterUnitType">
						<EnumerationValues>
							<IfcLabel-wrapper>ANALOG</IfcLabel-wrapper>
							<IfcLabel-wrapper>DIGITAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="MaterialColour_3yAyxI68v5rR3KlzC79inK" GlobalId="3yAyxI68v5rR3KlzC79inK" Name="MaterialColour" Description="Actual colour on the road marking material" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="MaterialThickness_2isecb3j59shOn6YU4eVwC" GlobalId="2isecb3j59shOn6YU4eVwC" Name="MaterialThickness" Description="Nominal thickness of the applied material" TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="MaterialType_1lAU4TV650ghJ4XdGFiLnC" GlobalId="1lAU4TV650ghJ4XdGFiLnC" Name="MaterialType" Description="Material type used... e.g. paint, tape, thermoplastic, stone" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="MaxAdjustmentX_ICS_3$jcm0qVeHuO00025QrE$V" GlobalId="3$jcm0qVeHuO00025QrE$V" Name="MaxAdjustmentX_ICS" Description="Provides the maximum setting value for the available current adjustment in relation to the Ics breaking capacity of the protection device of which the actual tripping unit is a part of. The value is not asserted unless the instantaneous time protection is." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="MaxAggregateSize_3mC2Q0qUmHuO00025QrE$V" GlobalId="3mC2Q0qUmHuO00025QrE$V" Name="MaxAggregateSize" Description="The maximum aggregate size of the concrete." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="MaxAmbientTemp_2bwEkyjJXFoviZOlfCxGbY" GlobalId="2bwEkyjJXFoviZOlfCxGbY" Name="MaxAmbientTemp" Description="Maximum ambient temperature of the site used as a basis of design" TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="MaxGrainSize_3YDB6b_Sf2KuuKISWe02i6" GlobalId="3YDB6b_Sf2KuuKISWe02i6" Name="MaxGrainSize" Description="Maximum grain size for the material." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="MaxGroundwaterInflow_1r_R2cU1zAd9hH_hcBobVb" GlobalId="1r_R2cU1zAd9hH_hcBobVb" Name="MaxGroundwaterInflow" Description="Groundwater inflow measured or expected durng a certain time span." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="MaximumAirFlowRate_17m9a0qT4HuO00025QrE$V" GlobalId="17m9a0qT4HuO00025QrE$V" Name="MaximumAirFlowRate" Description="Maximum allowable air flow rate." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="MaximumAllowedVoltageDrop_2fEJM0qTeHuO00025QrE$V" GlobalId="2fEJM0qTeHuO00025QrE$V" Name="MaximumAllowedVoltageDrop" Description="The maximum voltage drop across the circuit that must not be exceeded.
There are two  voltage drop limit settings that may be applied; one for sub-main circuits, and one in each Distribution Board or Consumer Unit for final circuits connected to that board. The settings should limit the overall voltage drop to the required level. Default settings of 1.5% for sub-main circuits and 2.5% for final circuits, giving an overall limit of 4% may be applied.
NOTE: This value may also be specified as a constraint within an IFC model if required but is included within the property set at this stage pending implementation of the required capabilities within software applications." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricVoltageMeasure" />
				<IfcSimplePropertyTemplate id="MaximumAngularVelocity_2PbvOcZIjFyhgvTPRNHKi4" GlobalId="2PbvOcZIjFyhgvTPRNHKi4" Name="MaximumAngularVelocity" Description="Identifies the maximum angular velocity of the kinematic behaviour." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAngularVelocityMeasure" />
				<IfcSimplePropertyTemplate id="MaximumApparentPower_2FPnK0qX4HuO00025QrE$V" GlobalId="2FPnK0qX4HuO00025QrE$V" Name="MaximumApparentPower" Description="Maximum apparent power/capacity in VA (volt ampere)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="MaximumAtmosphericPressure_0Qno0T109Cww7r$cstWuI3" GlobalId="0Qno0T109Cww7r$cstWuI3" Name="MaximumAtmosphericPressure" Description="Maximum level of atmospheric pressure that the equipment can operate effectively in." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="MaximumBendingRadius_0lxvCy45jAwx0T2d$IauLd" GlobalId="0lxvCy45jAwx0T2d$IauLd" Name="MaximumBendingRadius" Description="The maximum bending radius that the cable could withstand." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="MaximumCableLength_2W2E0jVrH8CuFa_0QTtWyt" GlobalId="2W2E0jVrH8CuFa_0QTtWyt" Name="MaximumCableLength" Description="Maximum cable length based on voltagedrop. NOTE: This value may also be specified as a constraint within an IFC model if required but is included within the property set at this stage pending implementation of the required capabilities within software applications." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="MaximumConstantSpeed_2GnYKK37P2XxUFvvgs8uSy" GlobalId="2GnYKK37P2XxUFvvgs8uSy" Name="MaximumConstantSpeed" Description="Identifies the maximum constant speed over the kinematic path." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLinearVelocityMeasure" />
				<IfcSimplePropertyTemplate id="MaximumCurrent_0w_s_0qUWHuO00025QrE$V" GlobalId="0w_s_0qUWHuO00025QrE$V" Name="MaximumCurrent" Description="The maximum allowed current that a device is certified to handle." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="MaximumDisplayDistance_1w3RnQrv17Lg3BEC7BotnA" GlobalId="1w3RnQrv17Lg3BEC7BotnA" Name="MaximumDisplayDistance" Description="The maximum distance that can be displayed. The value relates only to the signal type, not to the circumstances at a special position." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="MaximumDownstreamNavigableWaterLevel_2KNCBf$Sn0g848dtBdpxZF" GlobalId="2KNCBf$Sn0g848dtBdpxZF" Name="MaximumDownstreamNavigableWaterLevel" Description="Design maximum downstream water level for the lock complex" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="MaximumFlowRate_1a7000qUWHuO00025QrE$V" GlobalId="1a7000qUWHuO00025QrE$V" Name="MaximumFlowRate" Description="Maximum rate of flow which the meter is expected to pass." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="MaximumFlowRate_1xyuG0qUWHuO00025QrE$V" GlobalId="1xyuG0qUWHuO00025QrE$V" Name="MaximumFlowRate" Description="Maximum rate of flow which the meter is expected to pass." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="MaximumFlowRate_2PmEa0qUWHuO00025QrE$V" GlobalId="2PmEa0qUWHuO00025QrE$V" Name="MaximumFlowRate" Description="Maximum rate of flow which the meter is expected to pass." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="MaximumInsulatedVoltage_1Rmq9PJnfEKuHYQTF1jjZg" GlobalId="1Rmq9PJnfEKuHYQTF1jjZg" Name="MaximumInsulatedVoltage" Description="The max voltage that the insulation would operate normally" TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricVoltageMeasure" />
				<IfcSimplePropertyTemplate id="MaximumLineCount_28WAQCcEb5o8xMtoO1rOHY" GlobalId="28WAQCcEb5o8xMtoO1rOHY" Name="MaximumLineCount" Description="Maximum number of lines that may be secured to the mooring device." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="MaximumLineSlope_1frxgl$J1Dfv_kLsxsJGec" GlobalId="1frxgl$J1Dfv_kLsxsJGec" Name="MaximumLineSlope" Description="Maximum allowable line angle in degrees (negative if below horizontal from quay)" TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="MaximumLoadRetention_2cc4B89$DEvPshrGjbP3Kg" GlobalId="2cc4B89$DEvPshrGjbP3Kg" Name="MaximumLoadRetention" Description="Maximum possible impact load retention." TemplateType="p_singlevalue" PrimaryMeasureType="IfcForceMeasure" />
				<IfcSimplePropertyTemplate id="MaximumNoiseEmissions_02ksEi$yvANQhP$HONlrqo" GlobalId="02ksEi$yvANQhP$HONlrqo" Name="MaximumNoiseEmissions" Description="Maximum noise emissions limit at this location." TemplateType="p_singlevalue" PrimaryMeasureType="IfcSoundPowerLevelMeasure" />
				<IfcSimplePropertyTemplate id="MaximumNumberOfConnectedRUs_04WFhKT_r5UgPl35B9Wrbd" GlobalId="04WFhKT_r5UgPl35B9Wrbd" Name="MaximumNumberOfConnectedRUs" Description="Indicates the maximum number of remote units (RUs) which can be connected to the master unit." TemplateType="p_singlevalue" PrimaryMeasureType="IfcInteger" />
				<IfcSimplePropertyTemplate id="MaximumNumberOfManagedBSCs_2y9Cxd6R9B5xNzs7Z2VO_B" GlobalId="2y9Cxd6R9B5xNzs7Z2VO_B" Name="MaximumNumberOfManagedBSCs" Description="Indicates the maximum number of base station controller (BSC) that can be managed simultaneously by the mobile switching center (MSC)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcInteger" />
				<IfcSimplePropertyTemplate id="MaximumNumberOfRRUs_0tAsowuCH8xgtZ_ZgM$4Ug" GlobalId="0tAsowuCH8xgtZ_ZgM$4Ug" Name="MaximumNumberOfRRUs" Description="Indicates the maximum number of remote radio units (RRU) which can be connected to the baseband unit." TemplateType="p_singlevalue" PrimaryMeasureType="IfcInteger" />
				<IfcSimplePropertyTemplate id="MaximumOperatingTemperature_1juJk0qSSHuO00025QrE$V" GlobalId="1juJk0qSSHuO00025QrE$V" Name="MaximumOperatingTemperature" Description="The maximum temperature at which a cable or bus is certified to operate." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="MaximumOperatingTime_31nhczYx96JuYbkJ32Ejs4" GlobalId="31nhczYx96JuYbkJ32Ejs4" Name="MaximumOperatingTime" Description="The maximum duration of the turnout movement before the interlocking turns to out of control status." TemplateType="p_singlevalue" PrimaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="MaximumOutletPressure_38BCq0qSGHuO00025QrE$V" GlobalId="38BCq0qSGHuO00025QrE$V" Name="MaximumOutletPressure" Description="Maximum steam outlet pressure." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="MaximumPartLoadRatio_1J4CO0qSiHuO00025QrE$V" GlobalId="1J4CO0qSiHuO00025QrE$V" Name="MaximumPartLoadRatio" Description="Maximum part load ratio as a fraction of nominal capacity." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="MaximumPlateThickness_20lpI0qVOHuO00025QrE$V" GlobalId="20lpI0qVOHuO00025QrE$V" Name="MaximumPlateThickness" Description="This value may be needed for stress analysis and to handle buckling problems. It can also be derived from the given profile geometry or classification and therefore it is only an optional feature allowing for an explicit description. For example measured in mm." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="MaximumPlenumSensibleLoad_3U0RY0qUiHuO00025QrE$V" GlobalId="3U0RY0qUiHuO00025QrE$V" Name="MaximumPlenumSensibleLoad" Description="Maximum or Peak sensible thermal load contributed to return air plenum by the light fixture." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="MaximumPowerOutput_35FzM0qU0HuO00025QrE$V" GlobalId="35FzM0qU0HuO00025QrE$V" Name="MaximumPowerOutput" Description="The maximum output power rating of the engine." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="MaximumPowerOutput_3bRvI0qU0HuO00025QrE$V" GlobalId="3bRvI0qU0HuO00025QrE$V" Name="MaximumPowerOutput" Description="The maximum output power rating of the engine." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="MaximumPressureLoss_1euBG0qUWHuO00025QrE$V" GlobalId="1euBG0qUWHuO00025QrE$V" Name="MaximumPressureLoss" Description="Pressure loss expected across the meter under conditions of maximum flow." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="MaximumPressureLoss_2Vjie0qUWHuO00025QrE$V" GlobalId="2Vjie0qUWHuO00025QrE$V" Name="MaximumPressureLoss" Description="Pressure loss expected across the meter under conditions of maximum flow." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="MaximumRainIntensity_1HJs_aZFnBKP1bnlrIzkxt" GlobalId="1HJs_aZFnBKP1bnlrIzkxt" Name="MaximumRainIntensity" Description="Maximum level of rain intensity that the equipment can operate effectively in. It is usually measured in millimeter per hour (mm/h)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="MaximumSectionModulusY_3XJd60qVOHuO00025QrE$V" GlobalId="3XJd60qVOHuO00025QrE$V" Name="MaximumSectionModulusY" Description="Bending resistance about the ys axis at the point with maximum zs ordinate. For example measured in mm³." TemplateType="p_singlevalue" PrimaryMeasureType="IfcSectionModulusMeasure" />
				<IfcSimplePropertyTemplate id="MaximumSectionModulusZ_3pC1I0qVOHuO00025QrE$V" GlobalId="3pC1I0qVOHuO00025QrE$V" Name="MaximumSectionModulusZ" Description="Bending resistance about the zs axis at the point with maximum ys ordinate. For example measured in mm³." TemplateType="p_singlevalue" PrimaryMeasureType="IfcSectionModulusMeasure" />
				<IfcSimplePropertyTemplate id="MaximumShortCircuitCurrent_13Pj5R2Dr2uufzGEqODIOX" GlobalId="13Pj5R2Dr2uufzGEqODIOX" Name="MaximumShortCircuitCurrent" Description="Maximun short circuit current of the battery." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="MaximumShortCircuitTemperature_1$AaW0qSSHuO00025QrE$V" GlobalId="1$AaW0qSSHuO00025QrE$V" Name="MaximumShortCircuitTemperature" Description="The maximum short circuit temperature at which a cable or bus is certified to operate." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="MaximumSolarRadiation_3GwIZXL0151QO$6Rwbh8Tj" GlobalId="3GwIZXL0151QO$6Rwbh8Tj" Name="MaximumSolarRadiation" Description="Maximum level of solar irradiance that the equipment can operate effectively in. This is usually tested and measured by a national or international standard. The value indicates power density measured in watt per square meter (w/m2)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="MaximumSpaceSensibleLoad_3bACQ0qUiHuO00025QrE$V" GlobalId="3bACQ0qUiHuO00025QrE$V" Name="MaximumSpaceSensibleLoad" Description="Maximum or Peak sensible thermal load contributed to the conditioned space by the light fixture." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="MaximumSpeedLimitOfDivergingLine_3kTbdyPPL0ve7aTOCf7Kan" GlobalId="3kTbdyPPL0ve7aTOCf7Kan" Name="MaximumSpeedLimitOfDivergingLine" Description="Maximum speed for diverging line that corresponds to the type of turnout and design constraints." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLinearVelocityMeasure" />
				<IfcSimplePropertyTemplate id="MaximumSupportedWeight_2PYnA0qXKHuO00025QrE$V" GlobalId="2PYnA0qXKHuO00025QrE$V" Name="MaximumSupportedWeight" Description="The maximum weight that can be carried by the vibration isolator." TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassMeasure" />
				<IfcSimplePropertyTemplate id="MaximumTemperatureFactor_3QoL$QX913HhRDcJ6P3D8O" GlobalId="3QoL$QX913HhRDcJ6P3D8O" Name="MaximumTemperatureFactor" Description="Deviation in performance due to maximum design temperature" TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="MaximumTransferRate_0Az4uYaFHDRAo465uiJHuc" GlobalId="0Az4uYaFHDRAo465uiJHuc" Name="MaximumTransferRate" Description="Indicates the transmission rate in bit/s over the wired port." TemplateType="p_singlevalue" PrimaryMeasureType="IfcIntegerCountRateMeasure" />
				<IfcSimplePropertyTemplate id="MaximumTransmissionAttenuation_0v_sIcbmP5qfPydldRrfEw" GlobalId="0v_sIcbmP5qfPydldRrfEw" Name="MaximumTransmissionAttenuation" Description="Indicates the Maximum transmission attenuation of feeder." TemplateType="p_singlevalue" PrimaryMeasureType="IfcSoundPowerLevelMeasure" />
				<IfcSimplePropertyTemplate id="MaximumUnsupportedCut_103uAEL3z7QhsU6g8irstN" GlobalId="103uAEL3z7QhsU6g8irstN" Name="MaximumUnsupportedCut" Description="Maximum unsupported depth of cut." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNonNegativeLengthMeasure" />
				<IfcSimplePropertyTemplate id="MaximumUpstreamNavigableWaterLevel_3jdSJhHEL5WvgepJxzsoPV" GlobalId="3jdSJhHEL5WvgepJxzsoPV" Name="MaximumUpstreamNavigableWaterLevel" Description="Design maximum upstream water level for the lock complex" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="MaximumVelocity_3cdSC0qTeHuO00025QrE$V" GlobalId="3cdSC0qTeHuO00025QrE$V" Name="MaximumVelocity" Description="The maximum design velocity of the air in the duct or fitting." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLinearVelocityMeasure" />
				<IfcSimplePropertyTemplate id="MaximumVibration_0ZHdZ9S_zFTBfDpjz0f6mQ" GlobalId="0ZHdZ9S_zFTBfDpjz0f6mQ" Name="MaximumVibration" Description="Maximum tolerable vibration level of the device." TemplateType="p_singlevalue" PrimaryMeasureType="IfcFrequencyMeasure" />
				<IfcSimplePropertyTemplate id="MaximumWindSpeed_1btB4PB6T4pQcpyRRarqLn" GlobalId="1btB4PB6T4pQcpyRRarqLn" Name="MaximumWindSpeed" Description="Maximum resistance to wind load exposure." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLinearVelocityMeasure" />
				<IfcSimplePropertyTemplate id="MaximumWorkingPressure_1Jh5i0qT4HuO00025QrE$V" GlobalId="1Jh5i0qT4HuO00025QrE$V" Name="MaximumWorkingPressure" Description="Maximum pressure that the object is manufactured to withstand." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="MaximumWorkingPressure_1zS7o0qUSHuO00025QrE$V" GlobalId="1zS7o0qUSHuO00025QrE$V" Name="MaximumWorkingPressure" Description="Maximum pressure that the object is manufactured to withstand." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="MaxReaction_1I1q26Vcb1Oh7jw1XKWdxF" GlobalId="1I1q26Vcb1Oh7jw1XKWdxF" Name="MaxReaction" Description="Maximum reaction from the element" TemplateType="p_singlevalue" PrimaryMeasureType="IfcForceMeasure" />
				<IfcSimplePropertyTemplate id="MaxReactionTolerance_0PmqwfTKPD8AogG3WjSaaE" GlobalId="0PmqwfTKPD8AogG3WjSaaE" Name="MaxReactionTolerance" Description="Manufacturing tolerance on maximum reaction at fender support." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="MaxUnsupportedExcavationLength_1coGhCQG56WRQyuTdAF2Vg" GlobalId="1coGhCQG56WRQyuTdAF2Vg" Name="MaxUnsupportedExcavationLength" Description="Maximum unsupported length of excavation at the tunnel face." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNonNegativeLengthMeasure" />
				<IfcSimplePropertyTemplate id="MeanTimeBetweenFailure_2EilHdaS92vxcNcMLf5IrF" GlobalId="2EilHdaS92vxcNcMLf5IrF" Name="MeanTimeBetweenFailure" Description="The average time duration between instances of failure of a product." TemplateType="p_singlevalue" PrimaryMeasureType="IfcDuration" />
				<IfcSimplePropertyTemplate id="MeanTimeToRepair_3wO8ns0az0euk3DIe06ndR" GlobalId="3wO8ns0az0euk3DIe06ndR" Name="MeanTimeToRepair" Description="Mean time to repair." TemplateType="p_singlevalue" PrimaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="MeasuredFlowRate_06dQY0qXGHuO00025QrE$V" GlobalId="06dQY0qXGHuO00025QrE$V" Name="MeasuredFlowRate" Description="The rate of flow of a fluid measured across the valve." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcMassFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="MeasuredPressureDrop_0AoSO0qXGHuO00025QrE$V" GlobalId="0AoSO0qXGHuO00025QrE$V" Name="MeasuredPressureDrop" Description="The actual pressure drop in the fluid measured across the valve." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="MeasurementEndTime_2h0TtkB$f46PgH3YITllt2" GlobalId="2h0TtkB$f46PgH3YITllt2" Name="MeasurementEndTime" Description="Measurement/Monitoring period or point in time - end." TemplateType="p_singlevalue" PrimaryMeasureType="IfcDateTime" />
				<IfcSimplePropertyTemplate id="MeasurementStartTime_1e49rH$kr5xhN$GPo0KZPo" GlobalId="1e49rH$kr5xhN$GPo0KZPo" Name="MeasurementStartTime" Description="Measurement/Monitoring period or point in time - start." TemplateType="p_singlevalue" PrimaryMeasureType="IfcDateTime" />
				<IfcSimplePropertyTemplate id="MechanicalEfficiency_2cK3m0qVuHuO00025QrE$V" GlobalId="2cK3m0qVuHuO00025QrE$V" Name="MechanicalEfficiency" Description="The objects operational mechanical efficiency." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="MechanicalEfficiency_3gAKu0qSeHuO00025QrE$V" GlobalId="3gAKu0qSeHuO00025QrE$V" Name="MechanicalEfficiency" Description="The objects operational mechanical efficiency.

Ratio of the work (as measured) delivered to the gas to the work input to the compressor shaft." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="MechanicalLoadRating_1zjL_IETfD48CCr23pePYC" GlobalId="1zjL_IETfD48CCr23pePYC" Name="MechanicalLoadRating" Description="Mechanical load rating for this object.
It is provided according to the national building code." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="MechanicalLoadRating_3QctZVg8j5E8XzJ5bw45dT" GlobalId="3QctZVg8j5E8XzJ5bw45dT" Name="MechanicalLoadRating" Description="Mechanical load rating for this object.
It is provided according to the national building code." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="MechanicalOperated_1lCbY0qWSHuO00025QrE$V" GlobalId="1lCbY0qWSHuO00025QrE$V" Name="MechanicalOperated" Description="Indication whether the element is operated mechanically (TRUE) or not, i.e. manually (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="MechanicalStressType_0Xzh3BeoP5H9lg8s_GLbSq" GlobalId="0Xzh3BeoP5H9lg8s_GLbSq" Name="MechanicalStressType" Description="Indicates which type of stress is applied to the element." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_MechanicalStressType">
						<EnumerationValues>
							<IfcLabel-wrapper>MECHANICAL_COMPRESSION</IfcLabel-wrapper>
							<IfcLabel-wrapper>MECHANICAL_TRACTION</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="MechanicalTension_0NjLrbe5v3zuECrs8qsUAO" GlobalId="0NjLrbe5v3zuECrs8qsUAO" Name="MechanicalTension" Description="Nominal value of mechanical force applied to the element." TemplateType="p_singlevalue" PrimaryMeasureType="IfcForceMeasure" />
				<IfcSimplePropertyTemplate id="MechanicalVentilation_0b_MA3aeHFSwAPtjY25vZM" GlobalId="0b_MA3aeHFSwAPtjY25vZM" Name="MechanicalVentilation" Description="Indication whether the space is required to have mechanical ventilation (TRUE), or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="MechanicalVentilationRate_2QQtQ0qWmHuO00025QrE$V" GlobalId="2QQtQ0qWmHuO00025QrE$V" Name="MechanicalVentilationRate" Description="Indication of the requirement of a particular mechanical air ventilation rate, given in air changes per hour." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNumericMeasure" />
				<IfcSimplePropertyTemplate id="MediaContent_37Hcm0qS4HuO00025QrE$V" GlobalId="37Hcm0qS4HuO00025QrE$V" Name="MediaContent" Description="Indicates the media content storage location, such as URLs to camera footage within particular time periods." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="MediaExtendedArea_1$qTS0qUKHuO00025QrE$V" GlobalId="1$qTS0qUKHuO00025QrE$V" Name="MediaExtendedArea" Description="Total extended media area." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAreaMeasure" />
				<IfcSimplePropertyTemplate id="MediaSource_1n9VY0qS8HuO00025QrE$V" GlobalId="1n9VY0qS8HuO00025QrE$V" Name="MediaSource" Description="Indicates media sources and corresponding names of ports (IfcDistributionPort with FlowDirection=SINK and PredefinedType=AUDIOVISUAL) or aggregated audio/video components (IfcAudioVisualAppliance)." TemplateType="p_tablevalue" PrimaryMeasureType="IfcIdentifier" SecondaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="MediaSourceHistory_336aw0qS4HuO00025QrE$V" GlobalId="336aw0qS4HuO00025QrE$V" Name="MediaSourceHistory" Description="Indicates the media source where the identifier corresponds to an entry within the table of available media sources on Pset_AudioVisualApplianceTypeCommon.MediaSource." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcIdentifier" />
				<IfcSimplePropertyTemplate id="MenardLimitPressure_00Bl8r_Fv7u9veNYw6d5tJ" GlobalId="00Bl8r_Fv7u9veNYw6d5tJ" Name="MenardLimitPressure" Description="The limit pressure, resulting from interpretation of Menard&apos;s pressuremeter test." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="MenardLimitPressure_1CWkbvhoTDa9YkTFzoriqt" GlobalId="1CWkbvhoTDa9YkTFzoriqt" Name="MenardLimitPressure" Description="Limit pressure, resulting from interpretation of Menard&apos;s pressuremeter test." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="MenardLoadingUnloadingRatio_3NoxGP8K90k8Cg8dlw3vT7" GlobalId="3NoxGP8K90k8Cg8dlw3vT7" Name="MenardLoadingUnloadingRatio" Description="The reloading modulus, resulting from the interpretation of Menard&apos;s pressuremeter test." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="MenardPressuremeterModulus_3QXrblA1LFxhymk$1IR2rv" GlobalId="3QXrblA1LFxhymk$1IR2rv" Name="MenardPressuremeterModulus" Description="The first loading modulus, resulting from the interpretation of Menard&apos;s pressuremeter test." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="MessagingIDs_3waTWM9Eb3Q9wMddy_OIVB" GlobalId="3waTWM9Eb3Q9wMddy_OIVB" Name="MessagingIDs" Description="IDs or addresses for any other means of telecommunication, for example instant messaging, voice-over-IP, or file transfer protocols. The communication protocol is indicated by the URI value with scheme designations such as irc:, sip:, or ftp:." TemplateType="p_listvalue" PrimaryMeasureType="IfcURIReference" />
				<IfcSimplePropertyTemplate id="Methodology_2rVw3QGqHCNhBarO$sArmh" GlobalId="2rVw3QGqHCNhBarO$sArmh" Name="Methodology" Description="Methodology used to prepare the contents of the geotechnical assembly." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="Mg2_0IKcZxoxn5JhgLbQZ83Wbl" GlobalId="0IKcZxoxn5JhgLbQZ83Wbl" Name="Mg2+" Description="Content of Mg2+ in the water sample." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="MidshipToFairLead_38Dt4YAsL4reYsJ6egFlB$" GlobalId="38Dt4YAsL4reYsJ6egFlB$" Name="MidshipToFairLead" Description="Distance from the vessel midship to the fairlead for the line" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="MinAmbientTemp_3LmzG9mwD5cAShoiWv1sOj" GlobalId="3LmzG9mwD5cAShoiWv1sOj" Name="MinAmbientTemp" Description="Minimum ambient temperature of the site used as a basis of design" TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="MinCompressedFenderHeight_2jmteXu49EOgIrz0yF4reQ" GlobalId="2jmteXu49EOgIrz0yF4reQ" Name="MinCompressedFenderHeight" Description="Minimum height required for a compressed fender to prevent vessels striking the structure" TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="MineralComposition_0_NdsEekX2ZBhbUfaRHNgY" GlobalId="0_NdsEekX2ZBhbUfaRHNgY" Name="MineralComposition" Description="Description of the mineral composition according to ISO standard 14689:2017." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="MinimumAllowableSupportLength_3FQyy0qVGHuO00025QrE$V" GlobalId="3FQyy0qVGHuO00025QrE$V" Name="MinimumAllowableSupportLength" Description="The minimum allowable support length." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="MinimumDownstreamNavigableWaterLevel_2EA1AgdafA1wVAWJFBm1jo" GlobalId="2EA1AgdafA1wVAWJFBm1jo" Name="MinimumDownstreamNavigableWaterLevel" Description="Design minimum downstream water level for the lock complex" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="MinimumHeadroom_3c7I20qWeHuO00025QrE$V" GlobalId="3c7I20qWeHuO00025QrE$V" Name="MinimumHeadroom" Description="Headroom required for the activity assigned to this space." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="MinimumHeight_3uVsO0qTeHuO00025QrE$V" GlobalId="3uVsO0qTeHuO00025QrE$V" Name="MinimumHeight" Description="The minimum duct height for rectangular, oval or round duct." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="MinimumOperatingSpeed_0OpoQ0$Az5huboLE7511z3" GlobalId="0OpoQ0$Az5huboLE7511z3" Name="MinimumOperatingSpeed" Description="Minimum operating speed of the point machine." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAngularVelocityMeasure" />
				<IfcSimplePropertyTemplate id="MinimumOpticalSignalToNoiseRatio_0rh$rcZcL2wgr$IvyycBvf" GlobalId="0rh$rcZcL2wgr$IvyycBvf" Name="MinimumOpticalSignalToNoiseRatio" Description="Indicates the minimum optical signal to noise ratio of the transport equipment." TemplateType="p_singlevalue" PrimaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="MinimumPartLoadRatio_1Ditk0qSiHuO00025QrE$V" GlobalId="1Ditk0qSiHuO00025QrE$V" Name="MinimumPartLoadRatio" Description="Minimum part load ratio as a fraction of nominal capacity." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="MinimumPlateThickness_1sdJO0qVOHuO00025QrE$V" GlobalId="1sdJO0qVOHuO00025QrE$V" Name="MinimumPlateThickness" Description="This value may be needed for stress analysis and to handle buckling problems. It can also be derived from the given profile geometry or classification and therefore it is only an optional feature allowing for an explicit description. For example measured in mm." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="MinimumSectionModulusY_3hS700qVOHuO00025QrE$V" GlobalId="3hS700qVOHuO00025QrE$V" Name="MinimumSectionModulusY" Description="Bending resistance about the ys axis at the point with minimum zs ordinate. For example measured in mm³." TemplateType="p_singlevalue" PrimaryMeasureType="IfcSectionModulusMeasure" />
				<IfcSimplePropertyTemplate id="MinimumSectionModulusZ_3vlem0qVOHuO00025QrE$V" GlobalId="3vlem0qVOHuO00025QrE$V" Name="MinimumSectionModulusZ" Description="Bending resistance about the zs axis at the point with minimum ys ordinate. For example measured in mm³." TemplateType="p_singlevalue" PrimaryMeasureType="IfcSectionModulusMeasure" />
				<IfcSimplePropertyTemplate id="MinimumTemperatureFactor_0CbyYQjHD6gwW0KlswRtHt" GlobalId="0CbyYQjHD6gwW0KlswRtHt" Name="MinimumTemperatureFactor" Description="Deviation in performance due to minimum design temperature" TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="MinimumTensileStrength_1BfGlztTjDKfKH4_hnz50p" GlobalId="1BfGlztTjDKfKH4_hnz50p" Name="MinimumTensileStrength" Description="Indicates the minimum tensile strength." TemplateType="p_singlevalue" PrimaryMeasureType="IfcForceMeasure" />
				<IfcSimplePropertyTemplate id="MinimumTime_0WfkXHCXn70fx5kt6ZEVKM" GlobalId="0WfkXHCXn70fx5kt6ZEVKM" Name="MinimumTime" Description="Identifies the minimum time for the kinematic behaviour." TemplateType="p_singlevalue" PrimaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="MinimumUpstreamNavigableWaterLevel_3yYWu7oXT8NRxYQB125A$Q" GlobalId="3yYWu7oXT8NRxYQB125A$Q" Name="MinimumUpstreamNavigableWaterLevel" Description="Design minimum upstream water level for the lock complex" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="MinimumWidth_02eMI0qTiHuO00025QrE$V" GlobalId="02eMI0qTiHuO00025QrE$V" Name="MinimumWidth" Description="The minimum duct width for oval or rectangular duct." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="MinumumLineSlope_0yz2ivXvf3NhJNscddZLN0" GlobalId="0yz2ivXvf3NhJNscddZLN0" Name="MinumumLineSlope" Description="Minimum allowable line angle in degrees (negative if below horizontal from quay)" TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="MitigatedRiskConsequence_2FMrp8g1P97QhZQC8NiD8G" GlobalId="2FMrp8g1P97QhZQC8NiD8G" Name="MitigatedRiskConsequence" Description="Identifies the consequence of the hazard given the planned mitigation." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" id="i2055" Name="PEnum_RiskRating">
						<EnumerationValues>
							<IfcLabel-wrapper>CRITICAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>VERYHIGH</IfcLabel-wrapper>
							<IfcLabel-wrapper>HIGH</IfcLabel-wrapper>
							<IfcLabel-wrapper>CONSIDERABLE</IfcLabel-wrapper>
							<IfcLabel-wrapper>MODERATE</IfcLabel-wrapper>
							<IfcLabel-wrapper>SOME</IfcLabel-wrapper>
							<IfcLabel-wrapper>LOW</IfcLabel-wrapper>
							<IfcLabel-wrapper>VERYLOW</IfcLabel-wrapper>
							<IfcLabel-wrapper>INSIGNIFICANT</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="MitigatedRiskLikelihood_2mh3cZyunB0ONymM2LqXn$" GlobalId="2mh3cZyunB0ONymM2LqXn$" Name="MitigatedRiskLikelihood" Description="Identifies the likelihood of the hazard given the planned mitigation." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i2055" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="MitigatedRiskSignificance_3aZMkhheX3pPXI0xXDCzn0" GlobalId="3aZMkhheX3pPXI0xXDCzn0" Name="MitigatedRiskSignificance" Description="Identifies the significance of the risk given the mitigation of likelihood and consequence." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i2055" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="MitigationPlanned_1qnDxn1uP53Og8CTc_unk3" GlobalId="1qnDxn1uP53Og8CTc_unk3" Name="MitigationPlanned" Description="The planned (agreed and irrevocable) mitigation of the likelhood and consequences of the hazard." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="MitigationProposed_0AFQA2rm9398mY_MHHcg3U" GlobalId="0AFQA2rm9398mY_MHHcg3U" Name="MitigationProposed" Description="Any proposed, but not yet agreed and irrevocable, mitigation of the likelhood and consequences of the hazard." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="MixerControl_0iTtq0qXKHuO00025QrE$V" GlobalId="0iTtq0qXKHuO00025QrE$V" Name="MixerControl" Description="Defines the form of control of the mixing valve." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_MixingValveControl">
						<EnumerationValues>
							<IfcLabel-wrapper>MANUAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>PREDEFINED</IfcLabel-wrapper>
							<IfcLabel-wrapper>THERMOSTATIC</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="MnContent_0o8MhlkZ53UQY$AE8JFW5B" GlobalId="0o8MhlkZ53UQY$AE8JFW5B" Name="MnContent" Description="Content of Manganese. The unit must be defined in _&apos;IfcPropertySingleValue_._Unit&apos;_." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="ModelLabel_2C3MA0qUmHuO00025QrE$V" GlobalId="2C3MA0qUmHuO00025QrE$V" Name="ModelLabel" Description="The descriptive model name of the product model (or product line) as assigned by the manufacturer of the manufactured item." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ModelNumber_1jeF6zR3zCmAdTfELc98hB" GlobalId="1jeF6zR3zCmAdTfELc98hB" Name="ModelNumber" Description="The model number and/or unit designator assigned by the manufacturer of the manufactured item." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ModelPurpose_1gm$OqDpv9KQq3uIG1DEsc" GlobalId="1gm$OqDpv9KQq3uIG1DEsc" Name="ModelPurpose" Description="Purpose for which the model was done. Purpose could be e.g.: scientific study, mining, oil reservoir, geotechnics, hydrogeology, simulation or a URI from the codelist https://data.geoscience.earth/ncl/ModelPurpose." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ModelReference_24vbI0qUmHuO00025QrE$V" GlobalId="24vbI0qUmHuO00025QrE$V" Name="ModelReference" Description="The model number or designator of the product model (or product line) as assigned by the manufacturer of the manufactured item." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ModelStatus_16vVl01en6dv09d8hlKChk" GlobalId="16vVl01en6dv09d8hlKChk" Name="ModelStatus" Description="Status of the model. Status could be e.g.: ended, in-progress, in-development or a URI from the codelist https://data.geoscience.earth/ncl/ModelStatus." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ModelUseCase_0VofZ3$$j5mvopc7We4Ym7" GlobalId="0VofZ3$$j5mvopc7We4Ym7" Name="ModelUseCase" Description="Specifies the use case for which the model was created. ModelUseCase could be e.g.: stability assessment, quantity assessment, tendering etc." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="MoistureCapacityThermalGradient_0O7ue0qUqHuO00025QrE$V" GlobalId="0O7ue0qUqHuO00025QrE$V" Name="MoistureCapacityThermalGradient" Description="Thermal gradient coefficient for moisture capacity. Based on water vapor density." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="MoistureContent_1dieM0qUuHuO00025QrE$V" GlobalId="1dieM0qUuHuO00025QrE$V" Name="MoistureContent" Description="Total weight of moisture relative to oven-dried weight of the wood." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="MoistureDiffusivity_1iAcw0qUqHuO00025QrE$V" GlobalId="1iAcw0qUqHuO00025QrE$V" Name="MoistureDiffusivity" Description="Moisture diffusivity is a transport property that is frequently used in the hygrothermal analysis of building envelope components." TemplateType="p_singlevalue" PrimaryMeasureType="IfcMoistureDiffusivityMeasure" />
				<IfcSimplePropertyTemplate id="Molding_0$dALs9697$ulSebIsKQ5Q" GlobalId="0$dALs9697$ulSebIsKQ5Q" Name="Molding" Description="Label to indicate the material or construction of the molding around the space ceiling. The label is used for room book information.The material information is provided in absence of an IfcCovering (type=MOLDING) object with own shape representation and material assignment. In case of inconsistency the material assigned to IfcCovering elements takes precedence." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="MoldingHeight_0U099eBbD7ihB51GlGFk4H" GlobalId="0U099eBbD7ihB51GlGFk4H" Name="MoldingHeight" Description="Height of the molding.The height information is provided in absence of an IfcCovering (type=MOLDING) object with own shape representation and material assignment. In case of inconsistency the height assigned to IfcCovering elements takes precedence." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="MolecularWeight_3IOi60qUmHuO00025QrE$V" GlobalId="3IOi60qUmHuO00025QrE$V" Name="MolecularWeight" Description="Molecular weight of material (typically gas)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcMolecularWeightMeasure" />
				<IfcSimplePropertyTemplate id="MomentaryType_1CLtA0qWuHuO00025QrE$V" GlobalId="1CLtA0qWuHuO00025QrE$V" Name="MomentaryType" Description="A list of the available types of momentary switch from which that required may be selected." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_SwitchingDeviceMomentarySwitchType">
						<EnumerationValues>
							<IfcLabel-wrapper>BUTTON</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="MomentOfInertiaY_2biwU0qVOHuO00025QrE$V" GlobalId="2biwU0qVOHuO00025QrE$V" Name="MomentOfInertiaY" Description="Moment of inertia about ys (second moment of area, about ys). For example measured in mm4." TemplateType="p_singlevalue" PrimaryMeasureType="IfcMomentOfInertiaMeasure" />
				<IfcSimplePropertyTemplate id="MomentOfInertiaYZ_2rCl20qVOHuO00025QrE$V" GlobalId="2rCl20qVOHuO00025QrE$V" Name="MomentOfInertiaYZ" Description="Moment of inertia about ys and zs (product moment of area). For example measured in mm4." TemplateType="p_singlevalue" PrimaryMeasureType="IfcMomentOfInertiaMeasure" />
				<IfcSimplePropertyTemplate id="MomentOfInertiaZ_2jSqm0qVOHuO00025QrE$V" GlobalId="2jSqm0qVOHuO00025QrE$V" Name="MomentOfInertiaZ" Description="Moment of inertia about zs (second moment of area, about zs). For example measured in mm4" TemplateType="p_singlevalue" PrimaryMeasureType="IfcMomentOfInertiaMeasure" />
				<IfcSimplePropertyTemplate id="MoneyStuckRatio_0woPgPGeb8KAg_EvnJFaFT" GlobalId="0woPgPGeb8KAg_EvnJFaFT" Name="MoneyStuckRatio" Description="Indicates the ratio of money being stuck or jammed in appliance." TemplateType="p_singlevalue" PrimaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="MonitoringType_2QzF5YF2H02gNIuBB2WyHW" GlobalId="2QzF5YF2H02gNIuBB2WyHW" Name="MonitoringType" Description="Monitoring strategy chosen for the asset" TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_MonitoringType">
						<EnumerationValues>
							<IfcLabel-wrapper>IOT</IfcLabel-wrapper>
							<IfcLabel-wrapper>SENSORS</IfcLabel-wrapper>
							<IfcLabel-wrapper>PPM</IfcLabel-wrapper>
							<IfcLabel-wrapper>INSPECTION</IfcLabel-wrapper>
							<IfcLabel-wrapper>FEEDBACK</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="MotorDriveType_1RAI_0qUGHuO00025QrE$V" GlobalId="1RAI_0qUGHuO00025QrE$V" Name="MotorDriveType" Description="Motor drive type:
DIRECTDRIVE: Direct drive.
BELTDRIVE: Belt drive.
COUPLING: Coupling.
OTHER: Other type of motor drive.
UNKNOWN: Unknown motor drive type." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_FanMotorConnectionType">
						<EnumerationValues>
							<IfcLabel-wrapper>DIRECTDRIVE</IfcLabel-wrapper>
							<IfcLabel-wrapper>BELTDRIVE</IfcLabel-wrapper>
							<IfcLabel-wrapper>COUPLING</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="MotorEnclosureType_02f6C0qU4HuO00025QrE$V" GlobalId="02f6C0qU4HuO00025QrE$V" Name="MotorEnclosureType" Description="A list of the available types of motor enclosure from which that required may be selected." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_MotorEnclosureType">
						<EnumerationValues>
							<IfcLabel-wrapper>OPENDRIPPROOF</IfcLabel-wrapper>
							<IfcLabel-wrapper>TOTALLYENCLOSEDAIROVER</IfcLabel-wrapper>
							<IfcLabel-wrapper>TOTALLYENCLOSEDFANCOOLED</IfcLabel-wrapper>
							<IfcLabel-wrapper>TOTALLYENCLOSEDNONVENTILATED</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="MotorPosition_3iv6q0qUCHuO00025QrE$V" GlobalId="3iv6q0qUCHuO00025QrE$V" Name="MotorPosition" Description="Defines the location of the motor relative to the air stream.
InAirStream: Fan motor is in the air stream.
OutOfAirStream: Fan motor is out of the air stream." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_FanMotorPosition">
						<EnumerationValues>
							<IfcLabel-wrapper>INAIRSTREAM</IfcLabel-wrapper>
							<IfcLabel-wrapper>OUTOFAIRSTREAM</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Mountable_0nASgQh6r2huzTgAp_avpJ" GlobalId="0nASgQh6r2huzTgAp_avpJ" Name="Mountable" Description="Specifies whether the kerb can be readily climbed by a vehicle or not." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="Mounting_0ZoNk0qW8HuO00025QrE$V" GlobalId="0ZoNk0qW8HuO00025QrE$V" Name="Mounting" Description="The property enumeration Pset_SanitaryMountingEnum defines the forms of mounting or fixing of the sanitary terminal that may be specified within property sets used to define sanitary terminals (WC’s, basins, sinks, etc.) where:-

BackToWall:     A pedestal mounted sanitary terminal that fits flush to the wall at the rear to cover its service connections
Pedestal:   A floor mounted sanitary terminal that has an integral base
CounterTop:     A sanitary terminal that is installed into a horizontal surface that is installed into a horizontal surface. Note: When applied to a wash hand basin, the term more normally used is ‘vanity’. See also Wash Hand Basin Type specification.
WallHung:   A sanitary terminal cantilevered clear of the floor.

Note that BackToWall, Pedestal and WallHung are allowable values for a bidet." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" id="i2091" Name="PEnum_SanitaryMounting">
						<EnumerationValues>
							<IfcLabel-wrapper>BACKTOWALL</IfcLabel-wrapper>
							<IfcLabel-wrapper>PEDESTAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>COUNTERTOP</IfcLabel-wrapper>
							<IfcLabel-wrapper>WALLHUNG</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="MountingMethod_0IM4Q99JP0aPIH_odNLQo2" GlobalId="0IM4Q99JP0aPIH_odNLQo2" Name="MountingMethod" Description="The method of mounting cable segment occurrences on a cable carrier occurrence from which the method required can be selected. This is for the purpose of carrying out &apos;worst case&apos; cable sizing calculations and may be a conceptual requirement rather than a statement of the physical occurrences of cable and carrier segments." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_MountingMethodEnum">
						<EnumerationValues>
							<IfcLabel-wrapper>PERFORATEDTRAY</IfcLabel-wrapper>
							<IfcLabel-wrapper>LADDER</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="MountingOffset_351G60qWCHuO00025QrE$V" GlobalId="351G60qWCHuO00025QrE$V" Name="MountingOffset" Description="For counter top mounted basins the vertical offset between the top of the sink and the counter top." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="MountingOffset_39VUe0qWGHuO00025QrE$V" GlobalId="39VUe0qWGHuO00025QrE$V" Name="MountingOffset" Description="For counter top mounted basins the vertical offset between the top of the sink and the counter top." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="Mountings_0mEOFrv8f3iR74VNumT8C2" GlobalId="0mEOFrv8f3iR74VNumT8C2" Name="Mountings" Description="Specifies any mountings inserted in segment." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="MovementSensingType_3z3KG0qWKHuO00025QrE$V" GlobalId="3z3KG0qWKHuO00025QrE$V" Name="MovementSensingType" Description="Enumeration that identifies the type of movement sensing mechanism." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_MovementSensingType">
						<EnumerationValues>
							<IfcLabel-wrapper>PHOTOELECTRICCELL</IfcLabel-wrapper>
							<IfcLabel-wrapper>PRESSUREPAD</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="MullionThickness_0JOZR$$rr36wx2ZT$auLC5" GlobalId="0JOZR$$rr36wx2ZT$auLC5" Name="MullionThickness" Description="Thickness of the mullion.

For a window, it is the thickness of the mullion (i.e., the vertical separator of window panels within a window), measured parallel to the window elevation plane. The mullion is part of the lining and the mullion depth is assumed to be identical to the lining depth. If the MullionThickness is set to zero (and the MullionOffset set to a positive length), then the window is divided horizontally without a physical divider." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNonNegativeLengthMeasure" />
				<IfcSimplePropertyTemplate id="MultipleTarriff_10MBe0qUWHuO00025QrE$V" GlobalId="10MBe0qUWHuO00025QrE$V" Name="MultipleTarriff" Description="Indicates whether meter has built-in support for multiple tarriffs (variable energy cost rates)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="N_Protection_100_2uoNO0qVmHuO00025QrE$V" GlobalId="2uoNO0qVmHuO00025QrE$V" Name="N_Protection_100" Description="An indication whether the electronic tripping unit is tripping if the current in the N conductor is more than 100% of that of the phase conductors. The property is only asserted if the property N_Protection is asserted." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="N_Protection_2fIYq0qVmHuO00025QrE$V" GlobalId="2fIYq0qVmHuO00025QrE$V" Name="N_Protection" Description="An indication whether the electronic tripping unit has separate protection for the N conductor, or not." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="N_Protection_50_2mSJi0qVmHuO00025QrE$V" GlobalId="2mSJi0qVmHuO00025QrE$V" Name="N_Protection_50" Description="An indication whether the electronic tripping unit is tripping if the current in the N conductor is more than 50% of that of the phase conductors. The property is only asserted if the property N_Protection is asserted." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="N_Protection_Select_2_lrS0qVmHuO00025QrE$V" GlobalId="2_lrS0qVmHuO00025QrE$V" Name="N_Protection_Select" Description="An indication whether the use of the N_Protection can be selected by the user or not. If both the properties N_Protection_50 and N_Protection_100 are asserted, the value of N_Protection_Select property is set to TRUE. The property is only asserted if the property N_Protection is asserted." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="N20Content_2yLG40qUmHuO00025QrE$V" GlobalId="2yLG40qUmHuO00025QrE$V" Name="N20Content" Description="Nitrous oxide (N2O) content of the products of combustion. This is measured in weight of N2O per unit weight and is therefore unitless." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="Na_1yejeoaXj1gAsLahNn8Fv1" GlobalId="1yejeoaXj1gAsLahNn8Fv1" Name="Na+" Description="Content of Na+ in the water sample." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="NameFormat_0GYqVYWxT8AgvoGFCd4ZW3" GlobalId="0GYqVYWxT8AgvoGFCd4ZW3" Name="NameFormat" Description="Specifies a reference to or description of the formatting or encoding of the Name attribute of the _IfcReferent_ occurence." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="NarrativeText_0SX7o0qSOHuO00025QrE$V" GlobalId="0SX7o0qSOHuO00025QrE$V" Name="NarrativeText" Description="Added information relating to the adjacent building use that is not appropriate to the general descriptive text associated with an entity through the inherited IfcRoot.Description." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="NarrativeText_3F20_0qSKHuO00025QrE$V" GlobalId="3F20_0qSKHuO00025QrE$V" Name="NarrativeText" Description="Added information relating to the adjacent building use that is not appropriate to the general descriptive text associated with an entity through the inherited IfcRoot.Description." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="NarrowChannelWidth_260oCTccX4deJp$Xc0XFb_" GlobalId="260oCTccX4deJp$Xc0XFb_" Name="NarrowChannelWidth" Description="Indicates the width of the narrow channel." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="NaturalVentilation_2DJeU0qWmHuO00025QrE$V" GlobalId="2DJeU0qWmHuO00025QrE$V" Name="NaturalVentilation" Description="Indication whether the space is required to have natural ventilation (TRUE), or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="NaturalVentilationRate_2KTPM0qWmHuO00025QrE$V" GlobalId="2KTPM0qWmHuO00025QrE$V" Name="NaturalVentilationRate" Description="Indication of the requirement of a particular natural air ventilation rate, given in air changes per hour." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNumericMeasure" />
				<IfcSimplePropertyTemplate id="NatureOfRisk_0OyiwhoKjEQwHSx5sV_eCt" GlobalId="0OyiwhoKjEQwHSx5sV_eCt" Name="NatureOfRisk" Description="A description of the generic nature of the context or hazard that might be encountered." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="NeckAirVelocity_0khko0qRyHuO00025QrE$V" GlobalId="0khko0qRyHuO00025QrE$V" Name="NeckAirVelocity" Description="Air velocity at the neck." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcLinearVelocityMeasure" />
				<IfcSimplePropertyTemplate id="NeckArea_14SE60qS0HuO00025QrE$V" GlobalId="14SE60qS0HuO00025QrE$V" Name="NeckArea" Description="Neck area of the air terminal." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAreaMeasure" />
				<IfcSimplePropertyTemplate id="NetEarnedValue_3nJothH31Box8FgRkEz5JD" GlobalId="3nJothH31Box8FgRkEz5JD" Name="NetEarnedValue" Description="Net earned value" TemplateType="p_referencevalue" PrimaryMeasureType="IfcCostValue" />
				<IfcSimplePropertyTemplate id="NetImpedance_2j$Uc0qTeHuO00025QrE$V" GlobalId="2j$Uc0qTeHuO00025QrE$V" Name="NetImpedance" Description="The maximum earth loop impedance upstream of a circuit (typically stated as the variable Zs). This value is for 55o C (130oF) Celsius usage." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricResistanceMeasure" />
				<IfcSimplePropertyTemplate id="NetPlannedArea_06v7Q0qWaHuO00025QrE$V" GlobalId="06v7Q0qWaHuO00025QrE$V" Name="NetPlannedArea" Description="Total planned net area of the object. Used for programming the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAreaMeasure" />
				<IfcSimplePropertyTemplate id="NetPlannedArea_0PFC40qSKHuO00025QrE$V" GlobalId="0PFC40qSKHuO00025QrE$V" Name="NetPlannedArea" Description="Total planned net area of the object. Used for programming the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAreaMeasure" />
				<IfcSimplePropertyTemplate id="NetPlannedArea_30x9qx_FP9kRuQ6ZwfPT1O" GlobalId="30x9qx_FP9kRuQ6ZwfPT1O" Name="NetPlannedArea" Description="Total planned net area of the object. Used for programming the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAreaMeasure" />
				<IfcSimplePropertyTemplate id="NetPositiveSuctionHead_3rbco0qVuHuO00025QrE$V" GlobalId="3rbco0qVuHuO00025QrE$V" Name="NetPositiveSuctionHead" Description="Minimum liquid pressure at the pump inlet to prevent cavitation." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="NextAssessmentDate_28osmmdGL2buGNDbDCM1B0" GlobalId="28osmmdGL2buGNDbDCM1B0" Name="NextAssessmentDate" Description="Date of next condition inspection" TemplateType="p_singlevalue" PrimaryMeasureType="IfcDate" />
				<IfcSimplePropertyTemplate id="NiContent_1dnmq$hVHFi9E_V6sx8uof" GlobalId="1dnmq$hVHFi9E_V6sx8uof" Name="NiContent" Description="Content of Nickel. The unit must be defined in _&apos;IfcPropertySingleValue_._Unit&apos;_." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="NitrogenOxidesEmissions_1Y8SA6Uc98dRtm7sZssBm_" GlobalId="1Y8SA6Uc98dRtm7sZssBm_" Name="NitrogenOxidesEmissions" Description="Rate of emission of nitrogen oxides" TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="NO3_2mojFkIZf0RgDdRrAmsAvG" GlobalId="2mojFkIZf0RgDdRrAmsAvG" Name="NO3-" Description="Content of NO3- in the water sample." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="NoiseEmissions_0Quf032kD2sP$S5x5qU4Gx" GlobalId="0Quf032kD2sP$S5x5qU4Gx" Name="NoiseEmissions" Description="Level of sound emission" TemplateType="p_singlevalue" PrimaryMeasureType="IfcSoundPowerLevelMeasure" />
				<IfcSimplePropertyTemplate id="NominalAirFlowRate_1UPl00qT4HuO00025QrE$V" GlobalId="1UPl00qT4HuO00025QrE$V" Name="NominalAirFlowRate" Description="Nominal air flow rate." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="NominalAirFlowRate_2369C0qUGHuO00025QrE$V" GlobalId="2369C0qUGHuO00025QrE$V" Name="NominalAirFlowRate" Description="Nominal air flow rate." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="NominalAirFlowRate_2XQvW0qRuHuO00025QrE$V" GlobalId="2XQvW0qRuHuO00025QrE$V" Name="NominalAirFlowRate" Description="Nominal air flow rate." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="NominalAirFlowRate_3Xb400qUaHuO00025QrE$V" GlobalId="3Xb400qUaHuO00025QrE$V" Name="NominalAirFlowRate" Description="Nominal air flow rate.

Nominal rate of air flow into which water vapor is added." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="NominalBodyDepth_1hyfa0qXOHuO00025QrE$V" GlobalId="1hyfa0qXOHuO00025QrE$V" Name="NominalBodyDepth" Description="Nominal or quoted length measured along the z-axis of the local coordinate system of the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="NominalBodyDepth_1IEro0qUeHuO00025QrE$V" GlobalId="1IEro0qUeHuO00025QrE$V" Name="NominalBodyDepth" Description="Nominal or quoted length measured along the z-axis of the local coordinate system of the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="NominalBodyLength_12l1E0qUeHuO00025QrE$V" GlobalId="12l1E0qUeHuO00025QrE$V" Name="NominalBodyLength" Description="Nominal or quoted length measured along the x-axis of the local coordinate system of the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="NominalBodyLength_1QgOo0qXOHuO00025QrE$V" GlobalId="1QgOo0qXOHuO00025QrE$V" Name="NominalBodyLength" Description="Nominal or quoted length measured along the x-axis of the local coordinate system of the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="NominalBodyWidth_1AUxW0qUeHuO00025QrE$V" GlobalId="1AUxW0qUeHuO00025QrE$V" Name="NominalBodyWidth" Description="Nominal or quoted length, measured along the y-axis of the local coordinate system of the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="NominalBodyWidth_1Zcbu0qXOHuO00025QrE$V" GlobalId="1Zcbu0qXOHuO00025QrE$V" Name="NominalBodyWidth" Description="Nominal or quoted length, measured along the y-axis of the local coordinate system of the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="NominalCapacity_1rfDu0qSyHuO00025QrE$V" GlobalId="1rfDu0qSyHuO00025QrE$V" Name="NominalCapacity" Description="The total nominal or volumetric capacity of the object.

Nominal cooling tower capacity in terms of heat transfer rate of the cooling tower between air stream and water stream at nominal conditions." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="NominalCapacity_1Tori0qSiHuO00025QrE$V" GlobalId="1Tori0qSiHuO00025QrE$V" Name="NominalCapacity" Description="The total nominal or volumetric capacity of the object.

Compressor nameplate capacity." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="NominalCondensingTemperature_099k20qSaHuO00025QrE$V" GlobalId="099k20qSaHuO00025QrE$V" Name="NominalCondensingTemperature" Description="Chiller condensing temperature." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="NominalCoolingCapacity_3RtJ40qSuHuO00025QrE$V" GlobalId="3RtJ40qSuHuO00025QrE$V" Name="NominalCoolingCapacity" Description="Nominal cooling capacity." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="NominalCountedEfficiency_25Bo60qUKHuO00025QrE$V" GlobalId="25Bo60qUKHuO00025QrE$V" Name="NominalCountedEfficiency" Description="Nominal filter efficiency based the particle count concentration before and after the filter against particles with a certain size distribution." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="NominalCurrent_0sDhk0qUWHuO00025QrE$V" GlobalId="0sDhk0qUWHuO00025QrE$V" Name="NominalCurrent" Description="The nominal current that is designed to be measured." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="NominalCurrent_1Vh1C0qVaHuO00025QrE$V" GlobalId="1Vh1C0qVaHuO00025QrE$V" Name="NominalCurrent" Description="The nominal current that is designed to be measured.

A set of nominal currents in [A] for which the data of this instance is valid. At least one value shall be provided. Any value in the set shall not exceed the value of the UltimateRatedCurrent associated with the same breaker unit." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="NominalCurrent_3Gdli0qVWHuO00025QrE$V" GlobalId="3Gdli0qVWHuO00025QrE$V" Name="NominalCurrent" Description="The nominal current that is designed to be measured.

A set of nominal currents in [A] for which the data of this instance is valid. At least one value shall be provided. Any value in the set shall not exceed the value of the
UltimateRatedCurrent associated with the same breaker unit." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="NominalCurrentAdjusted_191hk0qViHuO00025QrE$V" GlobalId="191hk0qViHuO00025QrE$V" Name="NominalCurrentAdjusted" Description="An indication if the tripping currents of the short time protection is related to the nominal current multiplied with the actual setting of the current adjustment, if any, of the long time protection part of the protective device, or not." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="NominalCurrentAdjusted_1AWxG0qVeHuO00025QrE$V" GlobalId="1AWxG0qVeHuO00025QrE$V" Name="NominalCurrentAdjusted" Description="An indication if the tripping currents of the short time protection is related to the nominal current multiplied with the actual setting of the current adjustment, if any, of the long time protection part of the protective device, or not." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="NominalCurrentAdjusted_2oEVy0qVeHuO00025QrE$V" GlobalId="2oEVy0qVeHuO00025QrE$V" Name="NominalCurrentAdjusted" Description="An indication if the tripping currents of the short time protection is related to the nominal current multiplied with the actual setting of the current adjustment, if any, of the long time protection part of the protective device, or not." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="NominalCurrents_2kMQq0qVaHuO00025QrE$V" GlobalId="2kMQq0qVaHuO00025QrE$V" Name="NominalCurrents" Description="A set of values providing information on available modules (chips) for setting the nominal current of the protective device.

A set of nominal currents in [A] for which the data of this instance is valid. At least one value shall be provided. Any value in the set shall not exceed the value of the
UltimateRatedCurrent associated with the same breaker unit." TemplateType="p_listvalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="NominalCurrents_2Y8ny0qVmHuO00025QrE$V" GlobalId="2Y8ny0qVmHuO00025QrE$V" Name="NominalCurrents" Description="A set of values providing information on available modules (chips) for setting the nominal current of the protective device. If the set is empty, no nominal current modules are available for the tripping unit." TemplateType="p_listvalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="NominalDamperDiameter_3VQBm0qRuHuO00025QrE$V" GlobalId="3VQBm0qRuHuO00025QrE$V" Name="NominalDamperDiameter" Description="Nominal damper diameter." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="NominalDepth_0HZnE0qUaHuO00025QrE$V" GlobalId="0HZnE0qUaHuO00025QrE$V" Name="NominalDepth" Description="Nominal Depth of the object" TemplateType="p_singlevalue" PrimaryMeasureType="IfcNonNegativeLengthMeasure" />
				<IfcSimplePropertyTemplate id="NominalDiameter_2EWhC0qX8HuO00025QrE$V" GlobalId="2EWhC0qX8HuO00025QrE$V" Name="NominalDiameter" Description="Nominal diameter or width of the object.

Nominal diameter or width of the tubes in the tube bundle." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="NominalDiameter_2idNc0CVn4uOAABCTgvTXi" GlobalId="2idNc0CVn4uOAABCTgvTXi" Name="NominalDiameter" Description="Nominal diameter or width of the object.

The nominal diameter of the pipe connection." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="NominalDiameter_2QF5fCdFb1LPrQzIOCX_RZ" GlobalId="2QF5fCdFb1LPrQzIOCX_RZ" Name="NominalDiameter" Description="The nominal diameter of the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="NominalDiameter_30E560qVCHuO00025QrE$V" GlobalId="30E560qVCHuO00025QrE$V" Name="NominalDiameter" Description="Nominal diameter or width of the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="NominalDiameter_3583UJ6cD6cBUOPJ6Z7hRk" GlobalId="3583UJ6cD6cBUOPJ6Z7hRk" Name="NominalDiameter" Description="Nominal diameter or width of the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="NominalDiameterOrWidth_2eefu0qTuHuO00025QrE$V" GlobalId="2eefu0qTuHuO00025QrE$V" Name="NominalDiameterOrWidth" Description="The nominal diameter or width of the duct segment." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="NominalEfficiency_04OYo0qSaHuO00025QrE$V" GlobalId="04OYo0qSaHuO00025QrE$V" Name="NominalEfficiency" Description="Nominal object efficiency under nominal conditions." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="NominalEfficiency_3UEes0qSGHuO00025QrE$V" GlobalId="3UEes0qSGHuO00025QrE$V" Name="NominalEfficiency" Description="Nominal object efficiency under nominal conditions.

The nominal efficiency of the boiler as defined by the manufacturer. For water boilers, a function of inlet versus outlet temperature. Note: as two variables are used, DefiningValues and DefinedValues are null, and values are stored in IfcTable in the following order: InletTemperature(IfcThermodynamicTemperatureMeasure), OutletTemperature(IfcThermodynamicTemperatureMeasure), NominalEfficiency(IfcNormalisedRatioMeasure).  The IfcTable is related to IfcPropertyTableValue using IfcMetric and IfcResourceConstraintRelationship." TemplateType="p_tablevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" SecondaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="NominalEfficiencyTable_3CMEg0qSGHuO00025QrE$V" GlobalId="3CMEg0qSGHuO00025QrE$V" Name="NominalEfficiencyTable" Description="The nominal efficiency of the boiler as defined by the manufacturer. For steam boilers, a function of inlet temperature versus steam pressure. Note: as two variables are used, DefiningValues and DefinedValues are null, and values are stored in IfcTable in the following order: InletTemperature(IfcThermodynamicTemperatureMeasure) and OutletTemperature(IfcThermodynamicTemperatureMeasure) in DefiningValues, and NominalEfficiency(IfcNormalisedRatioMeasure) in DefinedValues. For example, DefininfValues(InletTemp, OutletTemp), DefinedValues(null, NominalEfficiency).  The IfcTable is related to IfcPropertyTableValue using IfcMetric and IfcResourceConstraintRelationship." TemplateType="p_tablevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" SecondaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="NominalEnergyConsumption_2fnj60qSGHuO00025QrE$V" GlobalId="2fnj60qSGHuO00025QrE$V" Name="NominalEnergyConsumption" Description="Nominal fuel consumption rate required to produce the total boiler heat output." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="NominalEvaporatingTemperature_0EX2i0qSaHuO00025QrE$V" GlobalId="0EX2i0qSaHuO00025QrE$V" Name="NominalEvaporatingTemperature" Description="Chiller evaporating temperature." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="NominalFilterFaceVelocity_3gWnA0qUKHuO00025QrE$V" GlobalId="3gWnA0qUKHuO00025QrE$V" Name="NominalFilterFaceVelocity" Description="Filter face velocity." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLinearVelocityMeasure" />
				<IfcSimplePropertyTemplate id="NominalFlowrate_3uE9W0qUKHuO00025QrE$V" GlobalId="3uE9W0qUKHuO00025QrE$V" Name="NominalFlowrate" Description="Nominal fluid flow rate through the filter." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="NominalFrequency_0rcYS0qU0HuO00025QrE$V" GlobalId="0rcYS0qU0HuO00025QrE$V" Name="NominalFrequency" Description="The nominal frequency of the supply." TemplateType="p_singlevalue" PrimaryMeasureType="IfcFrequencyMeasure" />
				<IfcSimplePropertyTemplate id="NominalFrequencyRange_3scdbKLST8Ge9QL74TErgy" GlobalId="3scdbKLST8Ge9QL74TErgy" Name="NominalFrequencyRange" Description="The upper and lower limits of frequency for which the operation of the device is certified." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcFrequencyMeasure" />
				<IfcSimplePropertyTemplate id="NominalHeatingCapacity_3y3F00qSuHuO00025QrE$V" GlobalId="3y3F00qSuHuO00025QrE$V" Name="NominalHeatingCapacity" Description="Nominal heating capacity." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="NominalHeatRejectionRate_0KUWm0qSaHuO00025QrE$V" GlobalId="0KUWm0qSaHuO00025QrE$V" Name="NominalHeatRejectionRate" Description="Sum of the refrigeration effect and the heat equivalent of the power input to the compressor." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="NominalHeatTransferArea_1dOBq0qUCHuO00025QrE$V" GlobalId="1dOBq0qUCHuO00025QrE$V" Name="NominalHeatTransferArea" Description="Nominal heat transfer surface area associated with nominal overall heat transfer coefficient." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAreaMeasure" />
				<IfcSimplePropertyTemplate id="NominalHeatTransferArea_36PmU0qSmHuO00025QrE$V" GlobalId="36PmU0qSmHuO00025QrE$V" Name="NominalHeatTransferArea" Description="Nominal heat transfer surface area associated with nominal overall heat transfer coefficient." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAreaMeasure" />
				<IfcSimplePropertyTemplate id="NominalHeatTransferCoefficient_1jLfu0qUCHuO00025QrE$V" GlobalId="1jLfu0qUCHuO00025QrE$V" Name="NominalHeatTransferCoefficient" Description="Nominal overall heat transfer coefficient associated with nominal heat transfer area." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermalTransmittanceMeasure" />
				<IfcSimplePropertyTemplate id="NominalHeatTransferCoefficient_3Bn580qSmHuO00025QrE$V" GlobalId="3Bn580qSmHuO00025QrE$V" Name="NominalHeatTransferCoefficient" Description="Nominal overall heat transfer coefficient associated with nominal heat transfer area." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermalTransmittanceMeasure" />
				<IfcSimplePropertyTemplate id="NominalHeight_00HWS0qUaHuO00025QrE$V" GlobalId="00HWS0qUaHuO00025QrE$V" Name="NominalHeight" Description="The nominal height of the object. The size information is provided in addition to the shape representation and the geometric parameters used within. In cases of inconsistency between the geometric parameters and the size properties, provided in the attached property set, the geometric parameters take precedence." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="NominalHeight_0ZM6gGT814qRBtBvJJdu5X" GlobalId="0ZM6gGT814qRBtBvJJdu5X" Name="NominalHeight" Description="Specifies the nominal height of the compartment." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="NominalHeight_19lK0$_1v7UxYDTioABcJZ" GlobalId="19lK0$_1v7UxYDTioABcJZ" Name="NominalHeight" Description="The nominal height of the object. The size information is provided in addition to the shape representation and the geometric parameters used within. In cases of inconsistency between the geometric parameters and the size properties, provided in the attached property set, the geometric parameters take precedence." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="NominalHeight_1Fy4XYaJXDTBDDb9f06ofi" GlobalId="1Fy4XYaJXDTBDDb9f06ofi" Name="NominalHeight" Description="The nominal height of the object. The size information is provided in addition to the shape representation and the geometric parameters used within. In cases of inconsistency between the geometric parameters and the size properties, provided in the attached property set, the geometric parameters take precedence." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNonNegativeLengthMeasure" />
				<IfcSimplePropertyTemplate id="NominalHeight_2GgGGOa7f1W9fIUx7l1f05" GlobalId="2GgGGOa7f1W9fIUx7l1f05" Name="NominalHeight" Description="The nominal height of the object. The size information is provided in addition to the shape representation and the geometric parameters used within. In cases of inconsistency between the geometric parameters and the size properties, provided in the attached property set, the geometric parameters take precedence.

The nominal height of the duct connection. Only provided for rectangular shaped ducts." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="NominalHeight_2HCjU0qXKHuO00025QrE$V" GlobalId="2HCjU0qXKHuO00025QrE$V" Name="NominalHeight" Description="The nominal height of the object. The size information is provided in addition to the shape representation and the geometric parameters used within. In cases of inconsistency between the geometric parameters and the size properties, provided in the attached property set, the geometric parameters take precedence.

Height of the vibration isolator before the application of load." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="NominalHeight_2mOaA0qTuHuO00025QrE$V" GlobalId="2mOaA0qTuHuO00025QrE$V" Name="NominalHeight" Description="The nominal height of the object. The size information is provided in addition to the shape representation and the geometric parameters used within. In cases of inconsistency between the geometric parameters and the size properties, provided in the attached property set, the geometric parameters take precedence." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="NominalHeight_3VRBe0qSOHuO00025QrE$V" GlobalId="3VRBe0qSOHuO00025QrE$V" Name="NominalHeight" Description="The nominal height of the object. The size information is provided in addition to the shape representation and the geometric parameters used within. In cases of inconsistency between the geometric parameters and the size properties, provided in the attached property set, the geometric parameters take precedence." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="NominalInletAirPressure_3PSji0qRuHuO00025QrE$V" GlobalId="3PSji0qRuHuO00025QrE$V" Name="NominalInletAirPressure" Description="Nominal airflow inlet static pressure." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="NominalInstallationDepth_2yE9Yxgxv0KRzH8vY2fcco" GlobalId="2yE9Yxgxv0KRzH8vY2fcco" Name="NominalInstallationDepth" Description="Nominal installation depth underground." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="NominalLatentCapacity_308rm0qSaHuO00025QrE$V" GlobalId="308rm0qSaHuO00025QrE$V" Name="NominalLatentCapacity" Description="Nominal latent capacity." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="NominalLength_07RHK0qUaHuO00025QrE$V" GlobalId="07RHK0qUaHuO00025QrE$V" Name="NominalLength" Description="The nominal overall length of the object. The size information is provided in addition to the shape representation and the geometric parameters used within. In case of inconsistency between the geometric parameters and the size properties, provided in the attached property set, the geometric parameters take precedence." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNonNegativeLengthMeasure" />
				<IfcSimplePropertyTemplate id="NominalLength_0NS18P1J51kRFniH3h5CIL" GlobalId="0NS18P1J51kRFniH3h5CIL" Name="NominalLength" Description="The nominal overall length of the object. The size information is provided in addition to the shape representation and the geometric parameters used within. In case of inconsistency between the geometric parameters and the size properties, provided in the attached property set, the geometric parameters take precedence." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNonNegativeLengthMeasure" />
				<IfcSimplePropertyTemplate id="NominalLength_3OohBqhOr7qe_LKHtDErK8" GlobalId="3OohBqhOr7qe_LKHtDErK8" Name="NominalLength" Description="The nominal overall length of the object. The size information is provided in addition to the shape representation and the geometric parameters used within. In case of inconsistency between the geometric parameters and the size properties, provided in the attached property set, the geometric parameters take precedence." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="NominalLengthOrDiameter_3lzLA0qWyHuO00025QrE$V" GlobalId="3lzLA0qWyHuO00025QrE$V" Name="NominalLengthOrDiameter" Description="The nominal length or, in the case of a vertical cylindrical tank, the nominal diameter of the tank." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="NominalLoad_2dKB03DRb7Wg298fNHgJuO" GlobalId="2dKB03DRb7Wg298fNHgJuO" Name="NominalLoad" Description="The nominal load that a component can support." TemplateType="p_singlevalue" PrimaryMeasureType="IfcForceMeasure" />
				<IfcSimplePropertyTemplate id="NominalMediaSurfaceVelocity_3khp00qUKHuO00025QrE$V" GlobalId="3khp00qUKHuO00025QrE$V" Name="NominalMediaSurfaceVelocity" Description="Average fluid velocity at the media surface." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLinearVelocityMeasure" />
				<IfcSimplePropertyTemplate id="NominalMoistureGain_3SDlM0qUaHuO00025QrE$V" GlobalId="3SDlM0qUaHuO00025QrE$V" Name="NominalMoistureGain" Description="Nominal rate of water vapor added into the airstream." TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="NominalParticleGeometricMeanDiameter_3zbUA0qUKHuO00025QrE$V" GlobalId="3zbUA0qUKHuO00025QrE$V" Name="NominalParticleGeometricMeanDiameter" Description="Particle geometric mean diameter associated with nominal efficiency." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="NominalParticleGeometricStandardDeviation_02yoq0qUOHuO00025QrE$V" GlobalId="02yoq0qUOHuO00025QrE$V" Name="NominalParticleGeometricStandardDeviation" Description="Particle geometric standard deviation associated with nominal efficiency." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="NominalPartLoadRatio_29bnA0qSGHuO00025QrE$V" GlobalId="29bnA0qSGHuO00025QrE$V" Name="NominalPartLoadRatio" Description="Allowable part load ratio range." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="NominalPower_2pu16hiH1CqQv04BNgxAph" GlobalId="2pu16hiH1CqQv04BNgxAph" Name="NominalPower" Description="A conventional value of apparent power determining a value of the rated current that may be carried with rated voltage applied, under specified conditions. ( IEV ref 421-04-04)" TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="NominalPowerConsumption_0PrrQ0qSaHuO00025QrE$V" GlobalId="0PrrQ0qSaHuO00025QrE$V" Name="NominalPowerConsumption" Description="Nominal total power consumption." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="NominalPowerRate_2RYAs0qUGHuO00025QrE$V" GlobalId="2RYAs0qUGHuO00025QrE$V" Name="NominalPowerRate" Description="Nominal fan power rate." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="NominalPressureDrop_3osqs0qUKHuO00025QrE$V" GlobalId="3osqs0qUKHuO00025QrE$V" Name="NominalPressureDrop" Description="Total pressure drop across the filter." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="NominalReturnWaterTemperatureCooling_3mkSI0qSuHuO00025QrE$V" GlobalId="3mkSI0qSuHuO00025QrE$V" Name="NominalReturnWaterTemperatureCooling" Description="Nominal return water temperature (refers to nominal cooling capacity)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="NominalReturnWaterTemperatureHeating_0AywA0qSyHuO00025QrE$V" GlobalId="0AywA0qSyHuO00025QrE$V" Name="NominalReturnWaterTemperatureHeating" Description="Nominal return water temperature (refers to nominal heating capacity)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="NominalRotationSpeed_2Mm$c0qUGHuO00025QrE$V" GlobalId="2Mm$c0qUGHuO00025QrE$V" Name="NominalRotationSpeed" Description="Rotational speed of the object under nominal conditions.

Nominal fan wheel speed." TemplateType="p_singlevalue" PrimaryMeasureType="IfcRotationalFrequencyMeasure" />
				<IfcSimplePropertyTemplate id="NominalRotationSpeed_3xZ4s0qVuHuO00025QrE$V" GlobalId="3xZ4s0qVuHuO00025QrE$V" Name="NominalRotationSpeed" Description="Rotational speed of the object under nominal conditions.

Pump rotational speed under nominal conditions." TemplateType="p_singlevalue" PrimaryMeasureType="IfcRotationalFrequencyMeasure" />
				<IfcSimplePropertyTemplate id="NominalSensibleCapacity_2xNgW0qSaHuO00025QrE$V" GlobalId="2xNgW0qSaHuO00025QrE$V" Name="NominalSensibleCapacity" Description="Nominal sensible capacity." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="NominalSize_2PhVA0qS8HuO00025QrE$V" GlobalId="2PhVA0qS8HuO00025QrE$V" Name="NominalSize" Description="Indicates the diagonal screen size." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="NominalSpacing_1dblNZi9nBpReQYP2Fv0zI" GlobalId="1dblNZi9nBpReQYP2Fv0zI" Name="NominalSpacing" Description="Specifies the nominal spacing between seals." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="NominalStaticPressure_2GpXY0qUGHuO00025QrE$V" GlobalId="2GpXY0qUGHuO00025QrE$V" Name="NominalStaticPressure" Description="The static pressure within the air stream that the fan must overcome to insure designed circulation of air." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="NominalSumpDepth_0uP3w0qXSHuO00025QrE$V" GlobalId="0uP3w0qXSHuO00025QrE$V" Name="NominalSumpDepth" Description="Nominal or quoted length measured along the z-axis in the local coordinate system of the sump." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="NominalSumpLength_0cWfk0qXSHuO00025QrE$V" GlobalId="0cWfk0qXSHuO00025QrE$V" Name="NominalSumpLength" Description="Nominal or quoted length measured along the x-axis in the local coordinate system or the radius (in the case of a circular shape in plan) of the sump." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="NominalSumpWidth_0m30E0qXSHuO00025QrE$V" GlobalId="0m30E0qXSHuO00025QrE$V" Name="NominalSumpWidth" Description="Nominal or quoted length measured along the y-axis in the local coordinate system of the sump." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="NominalSupplyCurrent_3hgdbiYpLERhPeEQfTel7i" GlobalId="3hgdbiYpLERhPeEQfTel7i" Name="NominalSupplyCurrent" Description="The nominal current of the supply." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="NominalSupplyVoltage_0f5Sw0qU0HuO00025QrE$V" GlobalId="0f5Sw0qU0HuO00025QrE$V" Name="NominalSupplyVoltage" Description="The nominal voltage of the supply." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricVoltageMeasure" />
				<IfcSimplePropertyTemplate id="NominalSupplyVoltageOffset_0kSna0qU0HuO00025QrE$V" GlobalId="0kSna0qU0HuO00025QrE$V" Name="NominalSupplyVoltageOffset" Description="The maximum and minimum allowed voltage of the supply e.g. boundaries of 380V/440V may be applied for a nominal voltage of 400V." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcElectricVoltageMeasure" />
				<IfcSimplePropertyTemplate id="NominalSupplyWaterTemperatureCooling_3hN7e0qSuHuO00025QrE$V" GlobalId="3hN7e0qSuHuO00025QrE$V" Name="NominalSupplyWaterTemperatureCooling" Description="Nominal supply water temperature (refers to nominal cooling capacity)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="NominalSupplyWaterTemperatureHeating_06Bkw0qSyHuO00025QrE$V" GlobalId="06Bkw0qSyHuO00025QrE$V" Name="NominalSupplyWaterTemperatureHeating" Description="Nominal supply water temperature (refers to nominal heating capacity)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="NominalSurroundingHumidityCooling_3cbyO0qSuHuO00025QrE$V" GlobalId="3cbyO0qSuHuO00025QrE$V" Name="NominalSurroundingHumidityCooling" Description="Nominal surrounding humidity (refers to nominal cooling capacity)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="NominalSurroundingTemperatureCooling_3Xqn80qSuHuO00025QrE$V" GlobalId="3Xqn80qSuHuO00025QrE$V" Name="NominalSurroundingTemperatureCooling" Description="Nominal surrounding temperature (refers to nominal cooling capacity)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="NominalSurroundingTemperatureHeating_01QZg0qSyHuO00025QrE$V" GlobalId="01QZg0qSyHuO00025QrE$V" Name="NominalSurroundingTemperatureHeating" Description="Nominal surrounding temperature (refers to nominal heating capacity)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="NominalThickness_2QgJLpWOb3xfvwr_YO$T_k" GlobalId="2QgJLpWOb3xfvwr_YO$T_k" Name="NominalThickness" Description="The nominal thickness of the object. The size information is provided in addition to the shape representation and the geometric parameters used within. In case of inconsistency between the geometric parameters and the size properties, provided in the attached property set, the geometric parameters take precedence." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNonNegativeLengthMeasure" />
				<IfcSimplePropertyTemplate id="NominalThickness_3cTq6sD71BVAf9l72L6lIy" GlobalId="3cTq6sD71BVAf9l72L6lIy" Name="NominalThickness" Description="The nominal thickness of the object. The size information is provided in addition to the shape representation and the geometric parameters used within. In case of inconsistency between the geometric parameters and the size properties, provided in the attached property set, the geometric parameters take precedence." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNonNegativeLengthMeasure" />
				<IfcSimplePropertyTemplate id="NominalThicknessEnd_2dzrJAQ351fhj1A45yJpqq" GlobalId="2dzrJAQ351fhj1A45yJpqq" Name="NominalThicknessEnd" Description="The nominal thickness of the object after a transition from its original value. The size information is provided in addition to the shape representation and the geometric parameters used within. In case of inconsistency between the geometric parameters and the size properties, provided in the attached property set, the geometric parameters take precedence." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNonNegativeLengthMeasure" />
				<IfcSimplePropertyTemplate id="NominalThroatThickness_3gpju0qUGHuO00025QrE$V" GlobalId="3gpju0qUGHuO00025QrE$V" Name="NominalThroatThickness" Description="Design value of the height of the largest isosceles triangle that can be inscribed in the section of a fillet weld.

&gt; REFERENCE&amp;nbsp; Symbol a according to ISO 2553:2019." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="NominalThrust_0473J1zsPCffpkaV4GfAVV" GlobalId="0473J1zsPCffpkaV4GfAVV" Name="NominalThrust" Description="The nominal thrust of the fan." TemplateType="p_singlevalue" PrimaryMeasureType="IfcForceMeasure" />
				<IfcSimplePropertyTemplate id="NominalToppingThickness_1RVVQ0qVKHuO00025QrE$V" GlobalId="1RVVQ0qVKHuO00025QrE$V" Name="NominalToppingThickness" Description="The nominal thickness of the topping." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="NominalTotalPressure_293dG0qUGHuO00025QrE$V" GlobalId="293dG0qUGHuO00025QrE$V" Name="NominalTotalPressure" Description="Nominal total pressure rise across the fan." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="NominalTransverseInclination_3Cd$wHaE95zeG4Dy9Ad2WJ" GlobalId="3Cd$wHaE95zeG4Dy9Ad2WJ" Name="NominalTransverseInclination" Description="Required nominal angle of transverse slope." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="NominalUA_35WAQ0qSaHuO00025QrE$V" GlobalId="35WAQ0qSaHuO00025QrE$V" Name="NominalUA" Description="Nominal UA value." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="NominalVoltage_3lq2xqPH9FnvgKOz8DOPYt" GlobalId="3lq2xqPH9FnvgKOz8DOPYt" Name="NominalVoltage" Description="The optimum voltage for the electrical appliance or system." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricVoltageMeasure" />
				<IfcSimplePropertyTemplate id="NominalWaterFlowCooling_3s5my0qSuHuO00025QrE$V" GlobalId="3s5my0qSuHuO00025QrE$V" Name="NominalWaterFlowCooling" Description="Nominal water flow (refers to nominal cooling capacity)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="NominalWaterFlowHeating_0GKEq0qSyHuO00025QrE$V" GlobalId="0GKEq0qSyHuO00025QrE$V" Name="NominalWaterFlowHeating" Description="Nominal water flow (refers to nominal heating capacity)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="NominalWeight_1NkoWVgmHA5xrENqUppTds" GlobalId="1NkoWVgmHA5xrENqUppTds" Name="NominalWeight" Description="Nominal weight of the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassMeasure" />
				<IfcSimplePropertyTemplate id="NominalWeightedEfficiency_2AZ6m0qUKHuO00025QrE$V" GlobalId="2AZ6m0qUKHuO00025QrE$V" Name="NominalWeightedEfficiency" Description="Nominal filter efficiency based the particle weight concentration before and after the filter against particles with a certain size distribution." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="NominalWidth_1iz8qzCsvEiApVczzesmrW" GlobalId="1iz8qzCsvEiApVczzesmrW" Name="NominalWidth" Description="Nominal or quoted width of the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="NominalWidth_1X9otKcjv7p8Guj7jHwQgt" GlobalId="1X9otKcjv7p8Guj7jHwQgt" Name="NominalWidth" Description="Specifies the nominal width of the compartment." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="NominalWidth_2aB9t8l_fBruh$Sc_$ZTMJ" GlobalId="2aB9t8l_fBruh$Sc_$ZTMJ" Name="NominalWidth" Description="The nominal overall width of the object. The size information is provided in addition to the shape representation and the geometric parameters used within. In cases of inconsistency between the geometric parameters and the size properties, provided in the attached property set, the geometric parameters take precedence." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="NominalWidth_2YZfyYRY1Aa9bsWGvZEaNq" GlobalId="2YZfyYRY1Aa9bsWGvZEaNq" Name="NominalWidth" Description="The nominal overall width of the object. The size information is provided in addition to the shape representation and the geometric parameters used within. In cases of inconsistency between the geometric parameters and the size properties, provided in the attached property set, the geometric parameters take precedence." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNonNegativeLengthMeasure" />
				<IfcSimplePropertyTemplate id="NominalWidthOrDiameter_3tjFS0qWyHuO00025QrE$V" GlobalId="3tjFS0qWyHuO00025QrE$V" Name="NominalWidthOrDiameter" Description="The nominal width or, in the case of a horizontal cylindrical tank, the nominal diameter of the tank.

Note: Not required for a vertical cylindrical tank." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="NonHazardousWaste_0Kqj40qU8HuO00025QrE$V" GlobalId="0Kqj40qU8HuO00025QrE$V" Name="NonHazardousWaste" Description="Quantity of non hazardous waste generated." TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassMeasure" />
				<IfcSimplePropertyTemplate id="NonHazardousWastePerUnit_2_PPA0qU4HuO00025QrE$V" GlobalId="2_PPA0qU4HuO00025QrE$V" Name="NonHazardousWastePerUnit" Description="Quantity of non hazardous waste generated" TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassMeasure" />
				<IfcSimplePropertyTemplate id="NonRenewableEnergyConsumption_0gu960qU8HuO00025QrE$V" GlobalId="0gu960qU8HuO00025QrE$V" Name="NonRenewableEnergyConsumption" Description="Quantity of non-renewable energy used as defined in ISO21930:2007" TemplateType="p_singlevalue" PrimaryMeasureType="IfcEnergyMeasure" />
				<IfcSimplePropertyTemplate id="NonRenewableEnergyConsumptionPerUnit_3L2_c0qU4HuO00025QrE$V" GlobalId="3L2_c0qU4HuO00025QrE$V" Name="NonRenewableEnergyConsumptionPerUnit" Description="Quantity of non-renewable energy used as defined in ISO21930:2007" TemplateType="p_singlevalue" PrimaryMeasureType="IfcEnergyMeasure" />
				<IfcSimplePropertyTemplate id="NosingLength_1iEcQ0qWqHuO00025QrE$V" GlobalId="1iEcQ0qWqHuO00025QrE$V" Name="NosingLength" Description="Horizontal distance from the front of the tread to the riser underneath. It is the overhang of the tread." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="NosingLength_2fumLUaIP77AfA4OwuJ2TH" GlobalId="2fumLUaIP77AfA4OwuJ2TH" Name="NosingLength" Description="Horizontal distance from the front of the tread to the riser underneath. It is the overhang of the tread." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfActors_00oAY0qRqHuO00025QrE$V" GlobalId="00oAY0qRqHuO00025QrE$V" Name="NumberOfActors" Description="The number of actors that are to be dealt with together in the population." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfAffectedPoles_0PbRBXQxbBDPGv$PwwmO6f" GlobalId="0PbRBXQxbBDPGv$PwwmO6f" Name="NumberOfAffectedPoles" Description="Number of poles that the equipment affects." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfAntennas_3pcohitgD84wYzTL$rzTOJ" GlobalId="3pcohitgD84wYzTL$rzTOJ" Name="NumberOfAntennas" Description="Indicates the number of antennas integrated in the device." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberofBlades_0z1WG0qT4HuO00025QrE$V" GlobalId="0z1WG0qT4HuO00025QrE$V" Name="NumberofBlades" Description="Number of blades." TemplateType="p_singlevalue" PrimaryMeasureType="IfcInteger" />
				<IfcSimplePropertyTemplate id="NumberOfBoltholes_2n1DG0qV8HuO00025QrE$V" GlobalId="2n1DG0qV8HuO00025QrE$V" Name="NumberOfBoltholes" Description="Number of boltholes in the flange." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfBolts_0mWUnJjvz5Fw1qK0NbSRYD" GlobalId="0mWUnJjvz5Fw1qK0NbSRYD" Name="NumberOfBolts" Description="Number of bolts in the bolted area." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfBranches_0bANhcBav7EhQtQmEUQDDQ" GlobalId="0bANhcBav7EhQtQmEUQDDQ" Name="NumberOfBranches" Description="Indicates the number of branches that can be supported by the optical splitter." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfCableEntries_1GIp0NSLHCAfwnDUczWxZc" GlobalId="1GIp0NSLHCAfwnDUczWxZc" Name="NumberOfCableEntries" Description="Indicates the number of cable entries in the manhole." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfCantilevers_2KK5NTKab9_g7iM9ioqV$u" GlobalId="2KK5NTKab9_g7iM9ioqV$u" Name="NumberOfCantilevers" Description="Indicates the number of cantilevers in the OCS supporting system." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfCarriers_07xDxpcsn6yA144GO_a3fc" GlobalId="07xDxpcsn6yA144GO_a3fc" Name="NumberOfCarriers" Description="Indicates how many carrier frequencies can be managed by the device." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfCells_3Grj20qSyHuO00025QrE$V" GlobalId="3Grj20qSyHuO00025QrE$V" Name="NumberOfCells" Description="Number of cells in one cooling tower unit." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfChairs_1B_B20qUaHuO00025QrE$V" GlobalId="1B_B20qUaHuO00025QrE$V" Name="NumberOfChairs" Description="Maximum number of chairs that can fit with the table for normal use." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfCircuits_1m7BU0qX8HuO00025QrE$V" GlobalId="1m7BU0qX8HuO00025QrE$V" Name="NumberOfCircuits" Description="Number of circuits.

Number of parallel fluid tube circuits." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfCoaxialPairs_38Z$45A$fEjAEjKJ1e9ONe" GlobalId="38Z$45A$fEjAEjKJ1e9ONe" Name="NumberOfCoaxialPairs" Description="Indicates the total number of coaxial pairs in the coaxial cable." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfCommonInterfaces_1DWcqAjZr43OGGCJpgy1j6" GlobalId="1DWcqAjZr43OGGCJpgy1j6" Name="NumberOfCommonInterfaces" Description="Indicates the number of common interfaces on the device." TemplateType="p_tablevalue" PrimaryMeasureType="IfcLabel" SecondaryMeasureType="IfcInteger" />
				<IfcSimplePropertyTemplate id="NumberOfCompartments_2mxjy0qSOHuO00025QrE$V" GlobalId="2mxjy0qSOHuO00025QrE$V" Name="NumberOfCompartments" Description="The number of separate internal compartments within the trunking." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfCoolingFans_2RNxHeP9b8vBeh97YG_WtE" GlobalId="2RNxHeP9b8vBeh97YG_WtE" Name="NumberOfCoolingFans" Description="Indicates the number of cooling fans in the equipment." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfCores_0n5KI0qSSHuO00025QrE$V" GlobalId="0n5KI0qSSHuO00025QrE$V" Name="NumberOfCores" Description="The number of cores." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfCores_1QcPI0qVOHuO00025QrE$V" GlobalId="1QcPI0qVOHuO00025QrE$V" Name="NumberOfCores" Description="The number of cores." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfCPUs_1rjaY2H_LBUB1VPn5lebft" GlobalId="1rjaY2H_LBUB1VPn5lebft" Name="NumberOfCPUs" Description="The number of CPUs used by the equipment." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfCrossedTracks_31ax3izS5EHwlYbat3DlDq" GlobalId="31ax3izS5EHwlYbat3DlDq" Name="NumberOfCrossedTracks" Description="Number of tracks crossed in cable route." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfDrafts_1NE_G0qSaHuO00025QrE$V" GlobalId="1NE_G0qSaHuO00025QrE$V" Name="NumberOfDrafts" Description="Number of the chimney drafts, continuous holes in the chimney through which the air passes, within the single chimney." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfEarthFaultRelays_1k$ZC8XKT1wuKG_W4CR0da" GlobalId="1k$ZC8XKT1wuKG_W4CR0da" Name="NumberOfEarthFaultRelays" Description="Indicates the number of relays used for preventing earth fault." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfEmergencyButtons_1ySlWeb$P2uBH_ablyiBv9" GlobalId="1ySlWeb$P2uBH_ablyiBv9" Name="NumberOfEmergencyButtons" Description="The number of emergency buttons built in the device." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfEmergencyTransceivers_2RrzYcZZf2sO3dp5bbzVgl" GlobalId="2RrzYcZZf2sO3dp5bbzVgl" Name="NumberOfEmergencyTransceivers" Description="Indicates the number of emergency transceivers in the base band unit." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfFibers_0ql_hsVrT7ZeyOizbL_4bp" GlobalId="0ql_hsVrT7ZeyOizbL_4bp" Name="NumberOfFibers" Description="Indicates the number of fibers in the single tube or cable." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfGangs_2TxWO0qUeHuO00025QrE$V" GlobalId="2TxWO0qUeHuO00025QrE$V" Name="NumberOfGangs" Description="Number of gangs in the object.

Number of slots available for switches/outlets (most commonly 1, 2, 3, or 4)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfGangs_2uXQQ0qWqHuO00025QrE$V" GlobalId="2uXQQ0qWqHuO00025QrE$V" Name="NumberOfGangs" Description="Number of gangs in the object.

Number of gangs/buttons on this switch." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfHoseConnections_2QyHQ0qUOHuO00025QrE$V" GlobalId="2QyHQ0qUOHuO00025QrE$V" Name="NumberOfHoseConnections" Description="The number of hose connections on the hydrant (excluding the pumper connection)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfInterfaces_3D0wHuI4P3guCzHoS3Y4Zf" GlobalId="3D0wHuI4P3guCzHoS3Y4Zf" Name="NumberOfInterfaces" Description="Indicates the types of interfaces and their number in the device." TemplateType="p_tablevalue" PrimaryMeasureType="IfcLabel" SecondaryMeasureType="IfcInteger" />
				<IfcSimplePropertyTemplate id="NumberOfLamps_29tB4ms5f55RLnGgTQOHCX" GlobalId="29tB4ms5f55RLnGgTQOHCX" Name="NumberOfLamps" Description="Number of lamps the signal is composed of." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfLampsNotUsed_0_13cp55j8ePtD_qiEfHkv" GlobalId="0_13cp55j8ePtD_qiEfHkv" Name="NumberOfLampsNotUsed" Description="Number of lamps which are not needed and blanked out (sealed)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfLiveConductors_04YqC0HsT3XhYwMsYCWtlQ" GlobalId="04YqC0HsT3XhYwMsYCWtlQ" Name="NumberOfLiveConductors" Description="Number of live conductors within this circuit. Either this property or the ConductorFunction property (if only one) may be asserted." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfManagedBTSs_0OHaQ3VtPDL8_RM8WL2hWr" GlobalId="0OHaQ3VtPDL8_RM8WL2hWr" Name="NumberOfManagedBTSs" Description="Indicates the maximum number of base transceiver stations (BTSs) that can be handled by the device." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfManagedCarriers_2dXLs2JgDDJAUunNKdvGyu" GlobalId="2dXLs2JgDDJAUunNKdvGyu" Name="NumberOfManagedCarriers" Description="Indicates how many carrier frequencies can be managed by the device." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfManholeCovers_3pgyG1ge167gvAIBWW6ZBC" GlobalId="3pgyG1ge167gvAIBWW6ZBC" Name="NumberOfManholeCovers" Description="Indicates the number of manhole covers." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfMeshLayers_1xLpRzB018EhsaurxTR7CZ" GlobalId="1xLpRzB018EhsaurxTR7CZ" Name="NumberOfMeshLayers" Description="Specifies the number of mesh layers." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfMultiModeFibers_21mdZfn9X5PwPW4Q$QPfW$" GlobalId="21mdZfn9X5PwPW4Q$QPfW$" Name="NumberOfMultiModeFibers" Description="Total number of multi-mode fibers in the optical fiber cable." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfOccupiedUnits_1BOKOcsX1EP83zoqRMmf4n" GlobalId="1BOKOcsX1EP83zoqRMmf4n" Name="NumberOfOccupiedUnits" Description="Indicates the number of vertical units occupied by the equipment." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfOverCurrentRelays_3_oAOIEqTAGwn2$PdOKte8" GlobalId="3_oAOIEqTAGwn2$PdOKte8" Name="NumberOfOverCurrentRelays" Description="Indicates number of relays used for preventing over current." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfOverlappingSpans_11jY1X9aT9DQa8E5Lr$tNh" GlobalId="11jY1X9aT9DQa8E5Lr$tNh" Name="NumberOfOverlappingSpans" Description="Number of overlapping spans in the overhead contactline system." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfPackets_3vGY$gzS1FU9Y3FCcw54as" GlobalId="3vGY$gzS1FU9Y3FCcw54as" Name="NumberOfPackets" Description="Indicates the number of packets of the IP network equipment." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfPanels_1j7Sa0qWeHuO00025QrE$V" GlobalId="1j7Sa0qWeHuO00025QrE$V" Name="NumberOfPanels" Description="Number of panels." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfParallelCircuits_1AWABiyr1Fnhe$8ZNYyby4" GlobalId="1AWABiyr1Fnhe$8ZNYyby4" Name="NumberOfParallelCircuits" Description="Number of parallel circuits." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfPhases_1BIplyxBLFfuml0KvHZ1y2" GlobalId="1BIplyxBLFfuml0KvHZ1y2" Name="NumberOfPhases" Description="Number of phases that the equipment operates on." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfPlates_2AZci0qUaHuO00025QrE$V" GlobalId="2AZci0qUaHuO00025QrE$V" Name="NumberOfPlates" Description="Number of plates used by the plate heat exchanger." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfPoles_1BMno0qTyHuO00025QrE$V" GlobalId="1BMno0qTyHuO00025QrE$V" Name="NumberOfPoles" Description="Number of poles that the object would affect.

The number of live lines that is intended to be handled by the device." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfPoles_2lqxx3IET2UhUPt$MJGW_4" GlobalId="2lqxx3IET2UhUPt$MJGW_4" Name="NumberOfPoles" Description="Number of poles that the object would affect.

Number of poles that the equipment would affect." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfPowerSupplyPorts_2zCP6ydR933h5ygkKmdVFt" GlobalId="2zCP6ydR933h5ygkKmdVFt" Name="NumberOfPowerSupplyPorts" Description="Indicates the number of power supply ports of the electric device." TemplateType="p_tablevalue" PrimaryMeasureType="IfcLabel" SecondaryMeasureType="IfcInteger" />
				<IfcSimplePropertyTemplate id="NumberOfRelays_2Yk89uN9b7hOCzGWSTtXeS" GlobalId="2Yk89uN9b7hOCzGWSTtXeS" Name="NumberOfRelays" Description="Indicates number of relays built in the device." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfRiser_3eW7e0qWmHuO00025QrE$V" GlobalId="3eW7e0qWmHuO00025QrE$V" Name="NumberOfRiser" Description="Total number of the risers included in the stair or stair flight." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfRows_1OHJE0qX8HuO00025QrE$V" GlobalId="1OHJE0qX8HuO00025QrE$V" Name="NumberOfRows" Description="Number of tube rows in the tube bundle assembly." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfScrews_2if5qEscD9_PYBlf2PakRS" GlobalId="2if5qEscD9_PYBlf2PakRS" Name="NumberOfScrews" Description="Number of screws/bolts/connections." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfSections_0ysIa0qX0HuO00025QrE$V" GlobalId="0ysIa0qX0HuO00025QrE$V" Name="NumberOfSections" Description="Number of sections.

Number of sections used in the construction of the tank. Default is 1.

Note: All sections assumed to be the same size." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfSections_1oUnE0qWeHuO00025QrE$V" GlobalId="1oUnE0qWeHuO00025QrE$V" Name="NumberOfSections" Description="Number of sections.

Number of vertical sections, measured in the direction of flow." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfSections_2zc2K0qX0HuO00025QrE$V" GlobalId="2zc2K0qX0HuO00025QrE$V" Name="NumberOfSections" Description="Number of sections.

Number of sections used in the construction of the tank

Note: All sections assumed to be the same size." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfSingleModeFibers_02lNFVtbrDlhiARV8DGc6Z" GlobalId="02lNFVtbrDlhiARV8DGc6Z" Name="NumberOfSingleModeFibers" Description="Total number of single-mode fibers in the optical fiber cable." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfSlots_2SMnY0qRyHuO00025QrE$V" GlobalId="2SMnY0qRyHuO00025QrE$V" Name="NumberOfSlots" Description="Indicates the number of  slots." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfSlots_3ol50yqfz8ZAv5ApU0vpo5" GlobalId="3ol50yqfz8ZAv5ApU0vpo5" Name="NumberOfSlots" Description="Indicates the number of  slots." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfSockets_3vt4ImC_v7wAtg_xlI2htO" GlobalId="3vt4ImC_v7wAtg_xlI2htO" Name="NumberOfSockets" Description="The number of sockets that may be connected. In case of inconsistency, sockets defined on ports take precedence." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfSources_2aoKY0qUiHuO00025QrE$V" GlobalId="2aoKY0qUiHuO00025QrE$V" Name="NumberOfSources" Description="Number of sources ." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfStoreys_0TQDw0qSKHuO00025QrE$V" GlobalId="0TQDw0qSKHuO00025QrE$V" Name="NumberOfStoreys" Description="The number of storeys within a building.
Captured for those cases where the IfcBuildingStorey entity is not used. Note that if IfcBuildingStorey is asserted and the number of storeys in a building can be determined from it, then this approach should be used in preference to setting a property for the number of storeys." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfThroughLanes_0V8hbusFnFk9GtjJUPdbt4" GlobalId="0V8hbusFnFk9GtjJUPdbt4" Name="NumberOfThroughLanes" Description="The total number of through lanes on the segment. This excludes auxiliary lanes, parking and turning lanes, acceleration/deceleration lanes, toll collection lanes, shoulders etc." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfTrackCenters_3PJ_4twh11JeX78ftqwr0D" GlobalId="3PJ_4twh11JeX78ftqwr0D" Name="NumberOfTrackCenters" Description="Indicates the number of track centers running over the sleepers." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfTracksCrossed_0tJ0zrZfrEWfrDbpRcmd38" GlobalId="0tJ0zrZfrEWfrDbpRcmd38" Name="NumberOfTracksCrossed" Description="Indicates the number of tracks which OCS supporting system crosses." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfTrafficInterfaces_09Z_XNzNLBnwwViB8ciE59" GlobalId="09Z_XNzNLBnwwViB8ciE59" Name="NumberOfTrafficInterfaces" Description="Indicates the number of traffic interfaces on the device." TemplateType="p_tablevalue" PrimaryMeasureType="IfcLabel" SecondaryMeasureType="IfcInteger" />
				<IfcSimplePropertyTemplate id="NumberOfTransceiversPerAntenna_0_R58gpyn2cPydhUJjYefc" GlobalId="0_R58gpyn2cPydhUJjYefc" Name="NumberOfTransceiversPerAntenna" Description="Indicates the number of transceivers per antenna." TemplateType="p_tablevalue" PrimaryMeasureType="IfcLabel" SecondaryMeasureType="IfcInteger" />
				<IfcSimplePropertyTemplate id="NumberOfTreads_3jHIu0qWmHuO00025QrE$V" GlobalId="3jHIu0qWmHuO00025QrE$V" Name="NumberOfTreads" Description="Total number of treads included in the stair or stairflight." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfTubes_3UkslSzBr10gMXXud95Exh" GlobalId="3UkslSzBr10gMXXud95Exh" Name="NumberOfTubes" Description="Number of fiber tubes." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfTwistedPairs_2FP39QShn07u1Ws2UmRi3_" GlobalId="2FP39QShn07u1Ws2UmRi3_" Name="NumberOfTwistedPairs" Description="Total number of twisted wire pairs in copper pair cables." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfUnits_21W3fiATv7tvnEAOCGtP5b" GlobalId="21W3fiATv7tvnEAOCGtP5b" Name="NumberOfUnits" Description="Indicates the number of vertical units." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfUntwistedPairs_3RNIDzSab848yblJ$4HXKU" GlobalId="3RNIDzSab848yblJ$4HXKU" Name="NumberOfUntwistedPairs" Description="Total number of untwisted wire pairs in the copper pair cable." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfWeldElements_0EaYG0qUKHuO00025QrE$V" GlobalId="0EaYG0qUKHuO00025QrE$V" Name="NumberOfWeldElements" Description="Number of weld elements.

&gt; REFERENCE&amp;nbsp; Symbol n according to ISO 2553:2019." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfWires_2vNnC4jfb7dgwh_lRMrBkU" GlobalId="2vNnC4jfb7dgwh_lRMrBkU" Name="NumberOfWires" Description="The number of wires used in the element." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NumberOfWorkstations_1NteTJwCTDPxZ$71U8R760" GlobalId="1NteTJwCTDPxZ$71U8R760" Name="NumberOfWorkstations" Description="Indicates the types or purposes of workstations and their number in the equipment. The defined purpose can be e.g. &apos;Diagnostic and maintenance&apos;, &apos;Traffic and electric traction&apos;, etc." TemplateType="p_tablevalue" PrimaryMeasureType="IfcLabel" SecondaryMeasureType="IfcInteger" />
				<IfcSimplePropertyTemplate id="NutsCount_3qNaC0qV0HuO00025QrE$V" GlobalId="3qNaC0qV0HuO00025QrE$V" Name="NutsCount" Description="Count of nuts to be mounted on one bolt" TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="NutShape_0BdJ20qV4HuO00025QrE$V" GlobalId="0BdJ20qV4HuO00025QrE$V" Name="NutShape" Description="Shape of the nut, e.g. &apos;Hexagon&apos;, &apos;Cap&apos;, &apos;Castle&apos;, &apos;Wing&apos;" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="NValue_2qQ8t_$IrCOuKLzuLwmHI8" GlobalId="2qQ8t_$IrCOuKLzuLwmHI8" Name="NValue" Description="Blow count from standard penetration testing, to ISO 22476-3, ASTM D1586[1] and Australian Standards AS 1289.6.3.1, which correlates to other engineering properties of soils." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="ObservationEndDate_1f3yCK9b927PPJI96ub41r" GlobalId="1f3yCK9b927PPJI96ub41r" Name="ObservationEndDate" Description="End date when the observation was made." TemplateType="p_singlevalue" PrimaryMeasureType="IfcDate" />
				<IfcSimplePropertyTemplate id="ObservationStartDate_0NUJ4QuQPDpehtroDooVHq" GlobalId="0NUJ4QuQPDpehtroDooVHq" Name="ObservationStartDate" Description="Start date when the observation was made." TemplateType="p_singlevalue" PrimaryMeasureType="IfcDate" />
				<IfcSimplePropertyTemplate id="OccupancyDiversity_0OoXU0qX4HuO00025QrE$V" GlobalId="0OoXU0qX4HuO00025QrE$V" Name="OccupancyDiversity" Description="Diversity factor that may be applied to the number of people in the space." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="OccupancyNumber_3FTic0qWeHuO00025QrE$V" GlobalId="3FTic0qWeHuO00025QrE$V" Name="OccupancyNumber" Description="Number of people required for the activity assigned to this space." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="OccupancyNumberPeak_3Kr1G0qWeHuO00025QrE$V" GlobalId="3Kr1G0qWeHuO00025QrE$V" Name="OccupancyNumberPeak" Description="Maximal number of people required for the activity assigned to this space in peak time." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="OccupancyTimePerDay_3QoVK0qWeHuO00025QrE$V" GlobalId="3QoVK0qWeHuO00025QrE$V" Name="OccupancyTimePerDay" Description="The amount of time during the day that the activity is required within this space." TemplateType="p_singlevalue" PrimaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="OccupancyType_0GI__0qSKHuO00025QrE$V" GlobalId="0GI__0qSKHuO00025QrE$V" Name="OccupancyType" Description="Occupancy type for this object.
It is defined according to the presiding national building code." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="OccupancyType_38Jxk0qWeHuO00025QrE$V" GlobalId="38Jxk0qWeHuO00025QrE$V" Name="OccupancyType" Description="Occupancy type for this object.
It is defined according to the presiding national building code." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="OCR_3J8URKaDb0hfGVNxhjZK2p" GlobalId="3J8URKaDb0hfGVNxhjZK2p" Name="OCR" Description="Ratio between pre-consolidation pressure and overburden pressure." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="OCSFasteningType_2gURBVuJP1TgJZ3PaUKlJ7" GlobalId="2gURBVuJP1TgJZ3PaUKlJ7" Name="OCSFasteningType" Description="Indicates the type of the overhead contact system (OCS) mechanical fastener." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_OCSFasteningType">
						<EnumerationValues>
							<IfcLabel-wrapper>SUPPORT_FITTING</IfcLabel-wrapper>
							<IfcLabel-wrapper>SUSPENSION_FITTING</IfcLabel-wrapper>
							<IfcLabel-wrapper>REGISTRATION_FITTING</IfcLabel-wrapper>
							<IfcLabel-wrapper>TERMINATION_FITTING</IfcLabel-wrapper>
							<IfcLabel-wrapper>TENSIONING_FITTING</IfcLabel-wrapper>
							<IfcLabel-wrapper>EARTHING_FITTING</IfcLabel-wrapper>
							<IfcLabel-wrapper>JOINT_FITTING</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="OCSType_2VGXY51WP7ahpqQLujiu8W" GlobalId="2VGXY51WP7ahpqQLujiu8W" Name="OCSType" Description="Indicates the type of overhead contactline system (OCS)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_OverheadContactLineType">
						<EnumerationValues>
							<IfcLabel-wrapper>TROLLY_TYPE_CONTACT_LINE</IfcLabel-wrapper>
							<IfcLabel-wrapper>TROLLY_TYPE_WITH_STITCHWIRE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OCL_WITH_CATENARY_SUSPENSION</IfcLabel-wrapper>
							<IfcLabel-wrapper>OCL_WITH_STITCHED_CATENARY_SUSPENSION</IfcLabel-wrapper>
							<IfcLabel-wrapper>COMPOUND_CATENARY_SUSPENSION</IfcLabel-wrapper>
							<IfcLabel-wrapper>RIGID_CATENARY</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="OldDevice_0o59a0qVmHuO00025QrE$V" GlobalId="0o59a0qVmHuO00025QrE$V" Name="OldDevice" Description="Indication whether the protection_ unit is out-dated or not. If not out-dated, the device is still for sale." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="OpenCircuitVoltage_2Qhz7hntj8tvEhto7ffFga" GlobalId="2Qhz7hntj8tvEhto7ffFga" Name="OpenCircuitVoltage" Description="Voltage of a cell or battery when the discharge current is zero [Source IEC 482-03-32]" TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricVoltageMeasure" />
				<IfcSimplePropertyTemplate id="OpenPressureDrop_1ZAwG0qT4HuO00025QrE$V" GlobalId="1ZAwG0qT4HuO00025QrE$V" Name="OpenPressureDrop" Description="Total pressure drop across damper." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="OperatingMode_1w5yc0qSGHuO00025QrE$V" GlobalId="1w5yc0qSGHuO00025QrE$V" Name="OperatingMode" Description="Identifies the operating mode of the boiler." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_BoilerOperatingMode">
						<EnumerationValues>
							<IfcLabel-wrapper>FIXED</IfcLabel-wrapper>
							<IfcLabel-wrapper>TWOSTEP</IfcLabel-wrapper>
							<IfcLabel-wrapper>MODULATING</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="OperatingWeight_0FZ7i0qX0HuO00025QrE$V" GlobalId="0FZ7i0qX0HuO00025QrE$V" Name="OperatingWeight" Description="Operating weight of the tank including all of its contents." TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassMeasure" />
				<IfcSimplePropertyTemplate id="Operation_3m8Ys0qT0HuO00025QrE$V" GlobalId="3m8Ys0qT0HuO00025QrE$V" Name="Operation" Description="The operational mechanism for the damper operation." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_DamperOperation">
						<EnumerationValues>
							<IfcLabel-wrapper>AUTOMATIC</IfcLabel-wrapper>
							<IfcLabel-wrapper>MANUAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="OperationalCriteria_2WvVW0qUGHuO00025QrE$V" GlobalId="2WvVW0qUGHuO00025QrE$V" Name="OperationalCriteria" Description="Time of operation at maximum operational ambient air temperature." TemplateType="p_singlevalue" PrimaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="OperationalDocument_0IY8b_L9X4sA7TO47jzP3_" GlobalId="0IY8b_L9X4sA7TO47jzP3_" Name="OperationalDocument" Description="Manufacturer&apos;s operational document" TemplateType="p_referencevalue" PrimaryMeasureType="IfcExternalReference" />
				<IfcSimplePropertyTemplate id="OperationalEfficiency_17RT40qSGHuO00025QrE$V" GlobalId="17RT40qSGHuO00025QrE$V" Name="OperationalEfficiency" Description="Operational efficiency: boiler output divided by total energy input (electrical and fuel)." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="OperationalTemperatureRange_2_eMO0qS0HuO00025QrE$V" GlobalId="2_eMO0qS0HuO00025QrE$V" Name="OperationalTemperatureRange" Description="The temperature range in which the device operates normally.

Allowable operation ambient air temperature range." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="OperationalTemperatureRange_2hvjQhIJj5c9PrmgrOQl1i" GlobalId="2hvjQhIJj5c9PrmgrOQl1i" Name="OperationalTemperatureRange" Description="The temperature range in which the device operates normally." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="OperationalTemperatureRange_2j48m0qSaHuO00025QrE$V" GlobalId="2j48m0qSaHuO00025QrE$V" Name="OperationalTemperatureRange" Description="The temperature range in which the device operates normally.

Allowable operational air temperature range." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="OperationMode_0wn9c0qXCHuO00025QrE$V" GlobalId="0wn9c0qXCHuO00025QrE$V" Name="OperationMode" Description="Table mapping operation mode identifiers to descriptive labels, which may be used for interpreting Pset_UnitaryControlElementPHistory.Mode." TemplateType="p_tablevalue" PrimaryMeasureType="IfcIdentifier" SecondaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="OperationModeHistory_0JRSo0qXCHuO00025QrE$V" GlobalId="0JRSo0qXCHuO00025QrE$V" Name="OperationModeHistory" Description="Indicates operation mode corresponding to Pset_UnitaryControlTypeCommon.Mode. For example, &apos;HEAT&apos;, &apos;COOL&apos;, &apos;AUTO&apos;." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcIdentifier" />
				<IfcSimplePropertyTemplate id="OperationPressureMax_0Npy20qUOHuO00025QrE$V" GlobalId="0Npy20qUOHuO00025QrE$V" Name="OperationPressureMax" Description="Maximum pressure under normal operating conditions." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="OperationTemperatureRange_1wm5W0qUGHuO00025QrE$V" GlobalId="1wm5W0qUGHuO00025QrE$V" Name="OperationTemperatureRange" Description="Allowable operation ambient air temperature range." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="OperationTemperatureRange_2P9LG0qU8HuO00025QrE$V" GlobalId="2P9LG0qU8HuO00025QrE$V" Name="OperationTemperatureRange" Description="Allowable operation ambient air temperature range." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="OperationTemperatureRange_3b6is0qSyHuO00025QrE$V" GlobalId="3b6is0qSyHuO00025QrE$V" Name="OperationTemperatureRange" Description="Allowable operation ambient air temperature range." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="OperationTemperatureRange_3gk_U0qRuHuO00025QrE$V" GlobalId="3gk_U0qRuHuO00025QrE$V" Name="OperationTemperatureRange" Description="Allowable operation ambient air temperature range.

Allowable operational range of the ambient air temperature." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="OperationTemperatureRange_3TPYE0qUKHuO00025QrE$V" GlobalId="3TPYE0qUKHuO00025QrE$V" Name="OperationTemperatureRange" Description="Allowable operation ambient air temperature range." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="OperationType_1hpyRfu7HD7h$V2CjmYqL6" GlobalId="1hpyRfu7HD7h$V2CjmYqL6" Name="OperationType" Description="Type of operations. Also used to assign standard symbolic presentations according to national building standards.

For a permeable covering, it is the type of permeable covering operations. Also used to assign standard symbolic presentations according to national building standards." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_PermeableCoveringOperationEnum">
						<EnumerationValues>
							<IfcLabel-wrapper>GRILL</IfcLabel-wrapper>
							<IfcLabel-wrapper>LOUVER</IfcLabel-wrapper>
							<IfcLabel-wrapper>SCREEN</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="OperationType_33QLs5kbX0BxppsYy98anS" GlobalId="33QLs5kbX0BxppsYy98anS" Name="OperationType" Description="Type of operations. Also used to assign standard symbolic presentations according to national building standards.

For a window, it is the type of window panel operations. Also used to assign standard symbolic presentations according to national building standards." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_WindowPanelOperationEnum">
						<EnumerationValues>
							<IfcLabel-wrapper>BOTTOMHUNG</IfcLabel-wrapper>
							<IfcLabel-wrapper>FIXEDCASEMENT</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHEROPERATION</IfcLabel-wrapper>
							<IfcLabel-wrapper>PIVOTHORIZONTAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>PIVOTVERTICAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>REMOVABLECASEMENT</IfcLabel-wrapper>
							<IfcLabel-wrapper>SIDEHUNGLEFTHAND</IfcLabel-wrapper>
							<IfcLabel-wrapper>SIDEHUNGRIGHTHAND</IfcLabel-wrapper>
							<IfcLabel-wrapper>SLIDINGHORIZONTAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>SLIDINGVERTICAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>TILTANDTURNLEFTHAND</IfcLabel-wrapper>
							<IfcLabel-wrapper>TILTANDTURNRIGHTHAND</IfcLabel-wrapper>
							<IfcLabel-wrapper>TOPHUNG</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Operator_39FqXYJQT2U9LFyRW241DI" GlobalId="39FqXYJQT2U9LFyRW241DI" Name="Operator" Description="The organisation or agency responsible for commissioning the borehole (as opposed to the agency which drilled the borehole)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="OpticalCableStructure_3lG57$HT1009UobXR$iHbV" GlobalId="3lG57$HT1009UobXR$iHbV" Name="OpticalCableStructure" Description="Distinguishes between different structures of an optical fiber cable." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_OpticalCableStructureType">
						<EnumerationValues>
							<IfcLabel-wrapper>BREAKOUT</IfcLabel-wrapper>
							<IfcLabel-wrapper>LOOSETUBE</IfcLabel-wrapper>
							<IfcLabel-wrapper>PATCHCORD</IfcLabel-wrapper>
							<IfcLabel-wrapper>PIGTAIL</IfcLabel-wrapper>
							<IfcLabel-wrapper>TIGHTBUFFERED</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="OpticalNetworkUnitType_3MqyyGk_v15RyXHBF73XE8" GlobalId="3MqyyGk_v15RyXHBF73XE8" Name="OpticalNetworkUnitType" Description="Indicates the type of the optical network unit equipment." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_OpticalNetworkUnitType">
						<EnumerationValues>
							<IfcLabel-wrapper>ACTIVE</IfcLabel-wrapper>
							<IfcLabel-wrapper>PASSIVE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="OpticalSplitterType_01LueCMJjAXuijkI5GImgq" GlobalId="01LueCMJjAXuijkI5GImgq" Name="OpticalSplitterType" Description="Indicates the type of optical splitter, single mode or multi-mode." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_OpticalSplitterType">
						<EnumerationValues>
							<IfcLabel-wrapper>MULTIMODE</IfcLabel-wrapper>
							<IfcLabel-wrapper>SINGLEMODE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Options_27vq80qVWHuO00025QrE$V" GlobalId="27vq80qVWHuO00025QrE$V" Name="Options" Description="A statement of the options available in the agreement." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="OrganicMatterContent_0CMY_nRMTF7vr$SfHyXInr" GlobalId="0CMY_nRMTF7vr$SfHyXInr" Name="OrganicMatterContent" Description="The total carbon content in soil (test method after dry combustion, the organic carbon content is calculated from this content after correcting for carbonates present in the sample). The unit must be defined in _&apos;IfcPropertySingleValue_._Unit&apos;_." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="OrganicVolume_1XE1BR1QPCRhABB7nartLU" GlobalId="1XE1BR1QPCRhABB7nartLU" Name="OrganicVolume" Description="Relative volume of organic (peat/humus) stratum constituents especially soil." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumeMeasure" />
				<IfcSimplePropertyTemplate id="Organizations_0Ksewl9eXCOBb5HfyICi72" GlobalId="0Ksewl9eXCOBb5HfyICi72" Name="Organizations" Description="Name of the organization(s) involved in producing the model." TemplateType="p_listvalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="Orientation_3yfeO0qT0HuO00025QrE$V" GlobalId="3yfeO0qT0HuO00025QrE$V" Name="Orientation" Description="The intended orientation for the damper as specified by the manufacturer." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_DamperOrientation">
						<EnumerationValues>
							<IfcLabel-wrapper>VERTICAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>HORIZONTAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>VERTICALORHORIZONTAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="OrthogonalOrthogonality_0ijPx5qb9F0QxopE78gaal" GlobalId="0ijPx5qb9F0QxopE78gaal" Name="OrthogonalOrthogonality" Description="Indicative (95%-100%) range orthogonality associated to the horizontal shape and orientation in Y, if different to the overall orthogonality." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="OrthogonalStraightness_1o$cWyp49DFveZj70lz4fA" GlobalId="1o$cWyp49DFveZj70lz4fA" Name="OrthogonalStraightness" Description="Indicative (95%-100%) range straightness associated to the horizontal shape  in Y, if different to the overall straightness." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="OrthogonalTolerance_2_6AHTtATDgu5GyLAb6mQD" GlobalId="2_6AHTtATDgu5GyLAb6mQD" Name="OrthogonalTolerance" Description="Indicative (95%-100%) range tolerance associated to the horizontal shape and position in Y, if different to the overall tolerance." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="OrthogonalUncertainty_1lQaFq2abFIh90SuNnsYAy" GlobalId="1lQaFq2abFIh90SuNnsYAy" Name="OrthogonalUncertainty" Description="Indicative (95%-100%) range diameter associated to the horizontal shape and position in Y, if different to the horizontal uncertainty." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="OrthometricHeight_3pWIuI7GX20gqJ$iYrynJl" GlobalId="3pWIuI7GX20gqJ$iYrynJl" Name="OrthometricHeight" Description="The orthometric height is the vertical distance H along the plumb line from a point of interest to a reference surface known as the geoid, the vertical datum that approximates mean sea level." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="OutdoorEnvironment_2PYAiYllv5oQiyb9SiORsG" GlobalId="2PYAiYllv5oQiyb9SiORsG" Name="OutdoorEnvironment" Description="Adjustment of the service life resulting from the effect of the outdoor environment (where appropriate)" TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="OuterDiameter_1D65QTyIPFEwphBQILyT$Q" GlobalId="1D65QTyIPFEwphBQILyT$Q" Name="OuterDiameter" Description="The actual outer diameter of the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="OuterDiameter_3F7mG0qVCHuO00025QrE$V" GlobalId="3F7mG0qVCHuO00025QrE$V" Name="OuterDiameter" Description="The actual outer diameter of the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="OuterRadius_3xvu9UFlDF_vR3H68vBS1w" GlobalId="3xvu9UFlDF_vR3H68vBS1w" Name="OuterRadius" Description="The outer radius of the element." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="OutletConnectionSize_03y8A0qXSHuO00025QrE$V" GlobalId="03y8A0qXSHuO00025QrE$V" Name="OutletConnectionSize" Description="Size of the outlet connection from the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="OutletConnectionSize_16Pey0qXWHuO00025QrE$V" GlobalId="16Pey0qXWHuO00025QrE$V" Name="OutletConnectionSize" Description="Size of the outlet connection from the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="OutletConnectionSize_19h4k0qXKHuO00025QrE$V" GlobalId="19h4k0qXKHuO00025QrE$V" Name="OutletConnectionSize" Description="Size of the outlet connection from the object.

The size of the pipework connection from the mixing valve." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="OutletConnectionSize_1kLVA0qXWHuO00025QrE$V" GlobalId="1kLVA0qXWHuO00025QrE$V" Name="OutletConnectionSize" Description="Size of the outlet connection from the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="OutletConnectionSize_1WKw80qXSHuO00025QrE$V" GlobalId="1WKw80qXSHuO00025QrE$V" Name="OutletConnectionSize" Description="Size of the outlet connection from the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="OutletConnectionSize_1YKpm0qUeHuO00025QrE$V" GlobalId="1YKpm0qUeHuO00025QrE$V" Name="OutletConnectionSize" Description="Size of the outlet connection from the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="OutletConnectionSize_2GJtK0qXWHuO00025QrE$V" GlobalId="2GJtK0qXWHuO00025QrE$V" Name="OutletConnectionSize" Description="Size of the outlet connection from the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="OutletConnectionSize_2SEZU0qXOHuO00025QrE$V" GlobalId="2SEZU0qXOHuO00025QrE$V" Name="OutletConnectionSize" Description="Size of the outlet connection from the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="OutletConnectionSize_3iPSc0qXSHuO00025QrE$V" GlobalId="3iPSc0qXSHuO00025QrE$V" Name="OutletConnectionSize" Description="Size of the outlet connection from the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="OutletDiameter_1PO6k0qUOHuO00025QrE$V" GlobalId="1PO6k0qUOHuO00025QrE$V" Name="OutletDiameter" Description="The outlet diameter of the breeching inlet." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="OutletTemperatureRange_2ZqF20qSGHuO00025QrE$V" GlobalId="2ZqF20qSGHuO00025QrE$V" Name="OutletTemperatureRange" Description="Allowable outlet temperature of either the water or the steam." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="OutputCapacity_1Tde00qWeHuO00025QrE$V" GlobalId="1Tde00qWeHuO00025QrE$V" Name="OutputCapacity" Description="Total nominal heat output as listed by the manufacturer." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="OutputCapacityCurve_2skUG0qWaHuO00025QrE$V" GlobalId="2skUG0qWaHuO00025QrE$V" Name="OutputCapacityCurve" Description="Partial output capacity curve (as a function of water temperature); Q = f (Twater)." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" />
				<IfcSimplePropertyTemplate id="OutputSignalType_2TKPRtqQfDlgGubE0HD4kt" GlobalId="2TKPRtqQfDlgGubE0HD4kt" Name="OutputSignalType" Description="The type of the output signal." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i1540" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="OutsideAirFlowrate_2XIRU0qXCHuO00025QrE$V" GlobalId="2XIRU0qXCHuO00025QrE$V" Name="OutsideAirFlowrate" Description="Flow rate of outside air entering the unit." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="OutsideAirPerPerson_0Ul$Y0qX4HuO00025QrE$V" GlobalId="0Ul$Y0qX4HuO00025QrE$V" Name="OutsideAirPerPerson" Description="Design quantity of outside air to be provided per person in the space." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="OutsideDiameter_2Msku0qX8HuO00025QrE$V" GlobalId="2Msku0qX8HuO00025QrE$V" Name="OutsideDiameter" Description="Actual outside diameter of the tube in the tube bundle." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="OverallDepth_1_40_0qVKHuO00025QrE$V" GlobalId="1_40_0qVKHuO00025QrE$V" Name="OverallDepth" Description="Overall depth of the profile." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="OverallDepth_3JJ240qVKHuO00025QrE$V" GlobalId="3JJ240qVKHuO00025QrE$V" Name="OverallDepth" Description="Overall depth of the profile." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="OverallDiameter_0urEa0qSSHuO00025QrE$V" GlobalId="0urEa0qSSHuO00025QrE$V" Name="OverallDiameter" Description="The overall diameter of a object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="OverallDiameter_1oyhg0qSWHuO00025QrE$V" GlobalId="1oyhg0qSWHuO00025QrE$V" Name="OverallDiameter" Description="The overall diameter of a object.

The overall diameter of a core (maximum space used)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="OverallEfficiency_0fi6G0qUGHuO00025QrE$V" GlobalId="0fi6G0qUGHuO00025QrE$V" Name="OverallEfficiency" Description="Total efficiency of object." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="OverallEfficiency_2fuyC0qVuHuO00025QrE$V" GlobalId="2fuyC0qVuHuO00025QrE$V" Name="OverallEfficiency" Description="Total efficiency of object.

The pump and motor overall operational efficiency." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="OverallOrthogonality_2Pm3H5PjH4qh$6CcPKvJ0F" GlobalId="2Pm3H5PjH4qh$6CcPKvJ0F" Name="OverallOrthogonality" Description="Indicative (95%-100%) range orthogonality associated to the intended shape and orientation in XYZ." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="OverallStraightness_0ujePSr190qh2qiYRtw0$1" GlobalId="0ujePSr190qh2qiYRtw0$1" Name="OverallStraightness" Description="Indicative (95%-100%) range straightness associated to the intended shape." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="OverallTolerance_3KnChrfTf4b9mBQQxryAs$" GlobalId="3KnChrfTf4b9mBQQxryAs$" Name="OverallTolerance" Description="Indicative (95%-100%) range tolerance associated to the intended shape and position in XYZ." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="OverallWidth_1fCtm0qVKHuO00025QrE$V" GlobalId="1fCtm0qVKHuO00025QrE$V" Name="OverallWidth" Description="Overall width of the profile." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="OverallWidth_3ClQc0qVKHuO00025QrE$V" GlobalId="3ClQc0qVKHuO00025QrE$V" Name="OverallWidth" Description="Overall width of the profile." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="Overburden_0Z9glM65n3EvhYmPteI6Jw" GlobalId="0Z9glM65n3EvhYmPteI6Jw" Name="Overburden" Description="Range of overburden (distance from tunnel to ground surface) in the subject section." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="OverlapLength_0vkCsg8vPFQRRT1mu2QiL9" GlobalId="0vkCsg8vPFQRRT1mu2QiL9" Name="OverlapLength" Description="Specifies the length of the mesh overlap." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="PackingCareType_0xcGE0qV8HuO00025QrE$V" GlobalId="0xcGE0qV8HuO00025QrE$V" Name="PackingCareType" Description="Identifies the predefined types of care that may be required when handling the artefact during a move where:

Fragile: artefact may be broken during a move through careless handling.
HandleWithCare: artefact may be damaged during a move through careless handling." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_PackingCareType">
						<EnumerationValues>
							<IfcLabel-wrapper>FRAGILE</IfcLabel-wrapper>
							<IfcLabel-wrapper>HANDLEWITHCARE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="PagerNumber_0JOaYbZHP97hOKRz09utzf" GlobalId="0JOaYbZHP97hOKRz09utzf" Name="PagerNumber" Description="The pager number at which paging messages may be received." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="PanelDepth_1fsUAU0FL6EgPG63h62fdV" GlobalId="1fsUAU0FL6EgPG63h62fdV" Name="PanelDepth" Description="Depth of the panel.

For a door, it is the depth of the door panel, measured perpendicular to the plane of the door leaf." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="PanelOperation_1ay2hmlBz0tgvLaClvI6lf" GlobalId="1ay2hmlBz0tgvLaClvI6lf" Name="PanelOperation" Description="The way of operation of a panel.

For a door, it is the way of operation of the panel. The PanelOperation of the door panel shall correspond to the OperationType of the _IfcDoorType_ by which it is referenced." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_DoorPanelOperationEnum">
						<EnumerationValues>
							<IfcLabel-wrapper>DOUBLE_ACTING</IfcLabel-wrapper>
							<IfcLabel-wrapper>FIXEDPANEL</IfcLabel-wrapper>
							<IfcLabel-wrapper>FOLDING</IfcLabel-wrapper>
							<IfcLabel-wrapper>REVOLVING</IfcLabel-wrapper>
							<IfcLabel-wrapper>ROLLINGUP</IfcLabel-wrapper>
							<IfcLabel-wrapper>SLIDING</IfcLabel-wrapper>
							<IfcLabel-wrapper>SWINGING</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTDEFINED</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="PanelPosition_0G5K7RuE12_RhCLZLW5MP4" GlobalId="0G5K7RuE12_RhCLZLW5MP4" Name="PanelPosition" Description="Position of the panel.

For a window, it is the position of the panel within the overall window style." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" id="i2418" Name="PEnum_WindowPanelPositionEnum">
						<EnumerationValues>
							<IfcLabel-wrapper>BOTTOM</IfcLabel-wrapper>
							<IfcLabel-wrapper>LEFT</IfcLabel-wrapper>
							<IfcLabel-wrapper>MIDDLE</IfcLabel-wrapper>
							<IfcLabel-wrapper>RIGHT</IfcLabel-wrapper>
							<IfcLabel-wrapper>TOP</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="PanelPosition_1y5RmsTUr2$RZ5QEXtb7tt" GlobalId="1y5RmsTUr2$RZ5QEXtb7tt" Name="PanelPosition" Description="Position of the panel.

For a permeable covering, it is the position of the permeable covering panel within the overall window or door type." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i2418" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="PanelPosition_2FriHyz6DAhOkwyiZ6nfWZ" GlobalId="2FriHyz6DAhOkwyiZ6nfWZ" Name="PanelPosition" Description="Position of the panel.

For a door, it is the position of the panel within the door. The PanelPosition of the door panel shall correspond to the OperationType of the _IfcDoorType_ by which it is referenced." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_DoorPanelPositionEnum">
						<EnumerationValues>
							<IfcLabel-wrapper>LEFT</IfcLabel-wrapper>
							<IfcLabel-wrapper>MIDDLE</IfcLabel-wrapper>
							<IfcLabel-wrapper>RIGHT</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="PanelWidth_0vNnM_UAj1FRUKankwRRer" GlobalId="0vNnM_UAj1FRUKankwRRer" Name="PanelWidth" Description="Width of the panel.

For a door, it is the width of the panel, given as ratio relative to the total clear opening width of the door. If omitted, it defaults to 1. A value shall be provided for all doors with OperationType&apos;s at IfcDoorType defining a door with more then one panel." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="PanHorizontal_0qyfW0qS8HuO00025QrE$V" GlobalId="0qyfW0qS8HuO00025QrE$V" Name="PanHorizontal" Description="Indicates horizontal range for panning." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="PanMounting_3thle0qWCHuO00025QrE$V" GlobalId="3thle0qWCHuO00025QrE$V" Name="PanMounting" Description="The property enumeration Pset_SanitaryMountingEnum defines the forms of mounting or fixing of the sanitary terminal that may be specified within property sets used to define sanitary terminals (WC’s, basins, sinks, etc.) where:-

BackToWall:     A pedestal mounted sanitary terminal that fits flush to the wall at the rear to cover its service connections.
Pedestal:   A floor mounted sanitary terminal that has an integral base.
CounterTop:     A sanitary terminal that is installed into a horizontal surface that is installed into a horizontal surface. Note: When applied to a wash hand basin, the term more normally used is ‘vanity’. See also Wash Hand Basin Type specification.
WallHung:   A sanitary terminal cantilevered clear of the floor." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i2091" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="PanTiltZoomPreset_0jClE0qS8HuO00025QrE$V" GlobalId="0jClE0qS8HuO00025QrE$V" Name="PanTiltZoomPreset" Description="Indicates pan/tilt/zoom position presets." TemplateType="p_tablevalue" PrimaryMeasureType="IfcIdentifier" SecondaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="PantographType_1qXzLtDkHAO9qk9H6cFVer" GlobalId="1qXzLtDkHAO9qk9H6cFVer" Name="PantographType" Description="Indicates the type of pantograph as a design parameter for the overhead contactline system." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="PanVertical_0y6QO0qS8HuO00025QrE$V" GlobalId="0y6QO0qS8HuO00025QrE$V" Name="PanVertical" Description="Indicates vertical range for panning." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="ParkingUnits_3$lcW0qWeHuO00025QrE$V" GlobalId="3$lcW0qWeHuO00025QrE$V" Name="ParkingUnits" Description="Indicates the number of transportation units of the type specified by the property ParkingUse that may be accommodated within the space. Generally, this value should default to 1 unit. However, where the parking space is for motorcycles or bicycles, provision may be made for more than one unit in the space." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="ParkingUse_3tPYq0qWeHuO00025QrE$V" GlobalId="3tPYq0qWeHuO00025QrE$V" Name="ParkingUse" Description="Identifies the type of transportation for which the parking space is designed. Values are not predefined but might include car, compact car, motorcycle, bicycle, truck, bus etc." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="PartialLoadEfficiencyCurves_2SgUA0qSGHuO00025QrE$V" GlobalId="2SgUA0qSGHuO00025QrE$V" Name="PartialLoadEfficiencyCurves" Description="Boiler efficiency as a function of the partial load factor; E = f (partialLaodfactor)." TemplateType="p_tablevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" SecondaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="ParticleAbsorptionCurve_0R_zu0qUOHuO00025QrE$V" GlobalId="0R_zu0qUOHuO00025QrE$V" Name="ParticleAbsorptionCurve" Description="Ratio of particles that are removed by the filter. Each entry describes the ratio of particles absorbed greater than equal to the specified size and less than the next specified size. For example, given for 3 significant particle sizes &gt;= 0,1 micro m, &gt;= 1 micro m, &gt;= 5 micro m" TemplateType="p_tablevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" SecondaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="ParticleMassHolding_0yTsY0qUKHuO00025QrE$V" GlobalId="0yTsY0qUKHuO00025QrE$V" Name="ParticleMassHolding" Description="Mass of particle holding in the filter." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcMassMeasure" />
				<IfcSimplePropertyTemplate id="ParticulateMatterEmissions_0PYDfb7nz3$hoT9UBbWKgS" GlobalId="0PYDfb7nz3$hoT9UBbWKgS" Name="ParticulateMatterEmissions" Description="Rate of emission of particulate matter" TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="PartLoadRatio_1JyYc0qSGHuO00025QrE$V" GlobalId="1JyYc0qSGHuO00025QrE$V" Name="PartLoadRatio" Description="Ratio of the real to the nominal capacity." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="PatternType_0KKIy0qX0HuO00025QrE$V" GlobalId="0KKIy0qX0HuO00025QrE$V" Name="PatternType" Description="Defines the types of pattern (or shape of a tank that may be specified." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" id="i2436" Name="PEnum_TankPatternType">
						<EnumerationValues>
							<IfcLabel-wrapper>HORIZONTALCYLINDER</IfcLabel-wrapper>
							<IfcLabel-wrapper>VERTICALCYLINDER</IfcLabel-wrapper>
							<IfcLabel-wrapper>RECTANGULAR</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="PatternType_1hLmG0qX0HuO00025QrE$V" GlobalId="1hLmG0qX0HuO00025QrE$V" Name="PatternType" Description="Defines the types of pattern (or shape of a tank that may be specified." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i2436" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="PavementRoughness_0r0gPVvcv1KPzot2_9fVt7" GlobalId="0r0gPVvcv1KPzot2_9fVt7" Name="PavementRoughness" Description="An assessment of the functional condition of the pavement surface indicated as an index according to the International Roughness Index (IRI)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNumericMeasure" />
				<IfcSimplePropertyTemplate id="PavementTexture_1JGNfhUnbBFe5yEOD_A8Fp" GlobalId="1JGNfhUnbBFe5yEOD_A8Fp" Name="PavementTexture" Description="Characterization of pavement texture by mean profile depth

&gt;NOTE&amp;nbsp; Definition according to ISO 13473-1:2019" TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="PaybackPeriod_0oFyQmlpL9PP5WtBwscQTm" GlobalId="0oFyQmlpL9PP5WtBwscQTm" Name="PaybackPeriod" Description="Payback period of investment" TemplateType="p_singlevalue" PrimaryMeasureType="IfcDuration" />
				<IfcSimplePropertyTemplate id="PaymentMethod_1d78lyWYfFdPdM0bVSZdC$" GlobalId="1d78lyWYfFdPdM0bVSZdC$" Name="PaymentMethod" Description="Indicates the vending machine payment method." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_PaymentMethod">
						<EnumerationValues>
							<IfcLabel-wrapper>CASH</IfcLabel-wrapper>
							<IfcLabel-wrapper>CARD</IfcLabel-wrapper>
							<IfcLabel-wrapper>E_PAYMENT</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="PbContent_1CZd8smoT6YPhHy6oCCq8c" GlobalId="1CZd8smoT6YPhHy6oCCq8c" Name="PbContent" Description="Content of Lead. The unit must be defined in _&apos;IfcPropertySingleValue_._Unit&apos;_." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="PeakCohesion_1TVc0spc13oOyuIwsuBSiU" GlobalId="1TVc0spc13oOyuIwsuBSiU" Name="PeakCohesion" Description="Cohesion is a shear strength parameter of soils. Its definition is derived from the Mohr-Coulomb failure criterion and is used to describe the shear resistance of soils that is independent from the normal effective stress. The peak value correspond to the maximum shear measured during the test." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="PeakFrictionAngle_0z1h4Y4EvBmefF2zOURpEQ" GlobalId="0z1h4Y4EvBmefF2zOURpEQ" Name="PeakFrictionAngle" Description="Soil effective stress friction angle is a shear strength parameter of soils. Its definition is derived from the Mohr-Coulomb failure criterion and is used to describe the friction shear resistance of soils with the normal effective stress. The peak value correspond to the maximum shear strength measured during the test." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="People_1k0og0qWiHuO00025QrE$V" GlobalId="1k0og0qWiHuO00025QrE$V" Name="People" Description="Heat gains and losses from people." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="PeopleHistory_3tilW0qWiHuO00025QrE$V" GlobalId="3tilW0qWiHuO00025QrE$V" Name="PeopleHistory" Description="Heat gains and losses from people." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="PercentageOpen_03ehW0qXGHuO00025QrE$V" GlobalId="03ehW0qXGHuO00025QrE$V" Name="PercentageOpen" Description="The ratio between the amount that the valve is open to the full open position of the valve." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="PercentShared_27XpU_GB5Ai8wh8ZfdIOsh" GlobalId="27XpU_GB5Ai8wh8ZfdIOsh" Name="PercentShared" Description="Percent of costs paid by the other infrastructure owner." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="Performance_1Nrta0qSyHuO00025QrE$V" GlobalId="1Nrta0qSyHuO00025QrE$V" Name="Performance" Description="Water temperature change as a function of wet-bulb temperature, water entering temperature, water flow rate, air flow rate, Tdiff = f ( Twet-bulb, Twater,in, mwater, mair)." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" />
				<IfcSimplePropertyTemplate id="PerformanceCertificate_3Hl5J4f$HClxP3X9VzH3yF" GlobalId="3Hl5J4f$HClxP3X9VzH3yF" Name="PerformanceCertificate" Description="Manufacturer&apos;s performance certificate" TemplateType="p_referencevalue" PrimaryMeasureType="IfcDocumentReference" />
				<IfcSimplePropertyTemplate id="PerformanceClasses_0Rkmq0qVqHuO00025QrE$V" GlobalId="0Rkmq0qVqHuO00025QrE$V" Name="PerformanceClasses" Description="A set of designations of performance classes for the breaker unit for which the data of this instance is valid. A breaker unit being a circuit breaker may be
constructed for different levels of breaking capacities. A maximum of 7 different
performance classes may be provided. Examples of performance classes that may be specified include B, C, N, S, H, L, V." TemplateType="p_listvalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="PerformanceClasses_3ZPV_0qVaHuO00025QrE$V" GlobalId="3ZPV_0qVaHuO00025QrE$V" Name="PerformanceClasses" Description="A set of designations of performance classes for the breaker unit for which the data of this instance is valid.

A set of designations of performance classes for the breaker unit for which the data of this instance is valid. A breaker unit being a motor protection device may be constructed for different levels of breaking capacities. A maximum of 7 different
performance classes may be provided. Examples of performance classes that may be specified include B, C, N, S, H, L, V." TemplateType="p_listvalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="PerformanceMaintenanceLevel_1iqiV1Bdv9kP1zFmTnxXvA" GlobalId="1iqiV1Bdv9kP1zFmTnxXvA" Name="PerformanceMaintenanceLevel" Description="Performance level at which maintenance takes place" TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="Perimeter_1m3hw0qVOHuO00025QrE$V" GlobalId="1m3hw0qVOHuO00025QrE$V" Name="Perimeter" Description="Perimeter of the object.

Perimeter of the profile for calculating the surface area. For example measured in mm." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="Permeability_3_l1K0qSyHuO00025QrE$V" GlobalId="3_l1K0qSyHuO00025QrE$V" Name="Permeability" Description="Ratio of the permeability of the ceiling.
The ration can be used to indicate an open ceiling (that enables identification of whether ceiling construction should be considered as impeding distribution of sprinkler water, light etc. from installations within the ceiling area)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="PermeabilityBehaviour_04LPHXtef7Bf46YoPubSZ$" GlobalId="04LPHXtef7Bf46YoPubSZ$" Name="PermeabilityBehaviour" Description="Proportionality constant in Darcy&apos;s law which relates flow rate and viscosity to a pressure gradient applied to the porous media." TemplateType="p_singlevalue" PrimaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="PermissibleRoadLoad_0dZw4UYSDFVPrQibCUZruL" GlobalId="0dZw4UYSDFVPrQibCUZruL" Name="PermissibleRoadLoad" Description="Permissible traffic load for the road design." TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassMeasure" />
				<IfcSimplePropertyTemplate id="PHLevel_0$mo80qUuHuO00025QrE$V" GlobalId="0$mo80qUuHuO00025QrE$V" Name="PHLevel" Description="Maximum water PH in a range from 0-14." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPHMeasure" />
				<IfcSimplePropertyTemplate id="PhotochemicalOzoneFormation_16v3C0qU8HuO00025QrE$V" GlobalId="16v3C0qU8HuO00025QrE$V" Name="PhotochemicalOzoneFormation" Description="Quantity of gases creating the photochemical ozone calculated in equivalent ethylene." TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassMeasure" />
				<IfcSimplePropertyTemplate id="PhotochemicalOzoneFormationPerUnit_3osKw0qU4HuO00025QrE$V" GlobalId="3osKw0qU4HuO00025QrE$V" Name="PhotochemicalOzoneFormationPerUnit" Description="Quantity of gases creating the photochemical ozone calculated in equivalent ethylene" TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassMeasure" />
				<IfcSimplePropertyTemplate id="PhysicalDescriptionReference_1KBMgHLx5B9BVSKUJEHSi9" GlobalId="1KBMgHLx5B9BVSKUJEHSi9" Name="PhysicalDescriptionReference" Description="Physical description as external reference of the equipment, including e.g.weight, shape, model, length, height, diameter." TemplateType="p_referencevalue" PrimaryMeasureType="IfcExternalReference" />
				<IfcSimplePropertyTemplate id="PictogramEscapeDirection_0eWpK0qUmHuO00025QrE$V" GlobalId="0eWpK0qUmHuO00025QrE$V" Name="PictogramEscapeDirection" Description="The direction of escape pictogram." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_PictogramEscapeDirectionType">
						<EnumerationValues>
							<IfcLabel-wrapper>RIGHTARROW</IfcLabel-wrapper>
							<IfcLabel-wrapper>LEFTARROW</IfcLabel-wrapper>
							<IfcLabel-wrapper>DOWNARROW</IfcLabel-wrapper>
							<IfcLabel-wrapper>UPARROW</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="PieceMark_0IBQS0qVKHuO00025QrE$V" GlobalId="0IBQS0qVKHuO00025QrE$V" Name="PieceMark" Description="Defines a unique piece for production purposes. All pieces with the same piece mark value are identical and interchangeable. The piece mark may be composed of sub-parts that have specific locally defined meaning (e.g. B-1A may denote a beam, of generic type ‘1’ and specific shape ‘A’)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="PieceMark_1WZdO0qVGHuO00025QrE$V" GlobalId="1WZdO0qVGHuO00025QrE$V" Name="PieceMark" Description="Defines a unique piece for production purposes. All pieces with the same piece mark value are identical and interchangeable. The piece mark may be composed of sub-parts that have specific locally defined meaning (e.g. B-1A may denote a beam, of generic type ‘1’ and specific shape ‘A’)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="PierSectionType_3FaWM7fvLCiBp0lVYAk03V" GlobalId="3FaWM7fvLCiBp0lVYAk03V" Name="PierSectionType" Description="Whether the structure presents a solid/closed barrier to the passage of water or is open." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" id="i2468" Name="PEnum_SectionType">
						<EnumerationValues>
							<IfcLabel-wrapper>OPEN</IfcLabel-wrapper>
							<IfcLabel-wrapper>CLOSED</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="PiezometricHead_24tPtOUmb38eSfLUcU_ipU" GlobalId="24tPtOUmb38eSfLUcU_ipU" Name="PiezometricHead" Description="Pressure head of water content." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="PiezometricPressure_3OfY_ZvlDCMeYOU3FtSlL2" GlobalId="3OfY_ZvlDCMeYOU3FtSlL2" Name="PiezometricPressure" Description="Pressure of water content." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="PipeConnection_0bnXS0qSyHuO00025QrE$V" GlobalId="0bnXS0qSyHuO00025QrE$V" Name="PipeConnection" Description="The manner in which the pipe connection is made to the cooled beam." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_CooledBeamPipeConnection">
						<EnumerationValues>
							<IfcLabel-wrapper>STRAIGHT</IfcLabel-wrapper>
							<IfcLabel-wrapper>RIGHT</IfcLabel-wrapper>
							<IfcLabel-wrapper>LEFT</IfcLabel-wrapper>
							<IfcLabel-wrapper>TOP</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="PitchAngle_19MOE0qWWHuO00025QrE$V" GlobalId="19MOE0qWWHuO00025QrE$V" Name="PitchAngle" Description="Angle of the slab to the horizontal when used as a component for the roof (specified as 0 degrees or not asserted for cases where the slab is not used as a roof component).The shape information is provided in addition to the shape representation and the geometric parameters used within. In cases of inconsistency between the geometric parameters and the shape properties, provided in the attached property, the geometric parameters take precedence. For geometry editing applications, like CAD: this value should be write-only." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="PlacementType_3Fx8gNev9BdO6QiED3BT8F" GlobalId="3Fx8gNev9BdO6QiED3BT8F" Name="PlacementType" Description="Indicates the purpose of the sensor placement." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_SensorPlacementType">
						<EnumerationValues>
							<IfcLabel-wrapper>MONITORING</IfcLabel-wrapper>
							<IfcLabel-wrapper>SURVEY</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="PlacingType_2_jbk0qUeHuO00025QrE$V" GlobalId="2_jbk0qUeHuO00025QrE$V" Name="PlacingType" Description="Location at which the type of junction box can be located." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_JunctionBoxPlacingType">
						<EnumerationValues>
							<IfcLabel-wrapper>CEILING</IfcLabel-wrapper>
							<IfcLabel-wrapper>FLOOR</IfcLabel-wrapper>
							<IfcLabel-wrapper>WALL</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="PlanarFlatness_1knSGb$Hr9DhsNhsqxn5bg" GlobalId="1knSGb$Hr9DhsNhsqxn5bg" Name="PlanarFlatness" Description="Indicative (95%-100%) range flatness associated to the intended shape and position in XYZ." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="PlanningControlStatus_0MZfk0qSOHuO00025QrE$V" GlobalId="0MZfk0qSOHuO00025QrE$V" Name="PlanningControlStatus" Description="Label of zoning category or class, or planning control category for the site or facility." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="PlanningControlStatus_394Yw0qSKHuO00025QrE$V" GlobalId="394Yw0qSKHuO00025QrE$V" Name="PlanningControlStatus" Description="Label of zoning category or class, or planning control category for the site or facility." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="PlasticityIndex_0$zff_imHDMetkQE35AOmz" GlobalId="0$zff_imHDMetkQE35AOmz" Name="PlasticityIndex" Description="The plasticity index Ip is the numerical difference between the liquid limit and plastic limit of a fine soil.  IP = wL - wP." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="PlasticityIndex_2LRVKFYkv7MBBC_EdSek5O" GlobalId="2LRVKFYkv7MBBC_EdSek5O" Name="PlasticityIndex" Description="The plasticity index Ip is the numerical difference between the liquid limit and plastic limit of a fine soil.  IP = wL - wP." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="PlasticLimit_2QRKg6a61Ft9rL$4_1Q7GD" GlobalId="2QRKg6a61Ft9rL$4_1Q7GD" Name="PlasticLimit" Description="The water content in percent where the soil starts  to behave as a semi-solid state.
&gt; NOTE&amp;nbsp; Definition according to ISO17892." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="PlasticShapeFactorY_0TWT80qVSHuO00025QrE$V" GlobalId="0TWT80qVSHuO00025QrE$V" Name="PlasticShapeFactorY" Description="Ratio of plastic versus elastic bending moment capacity about the section analysis axis ys. A dimensionless value." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="PlasticShapeFactorZ_0bGNQ0qVSHuO00025QrE$V" GlobalId="0bGNQ0qVSHuO00025QrE$V" Name="PlasticShapeFactorZ" Description="Ratio of plastic versus elastic bending moment capacity about the section analysis axis zs. A dimensionless value." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="PlasticStrain_3lv5i0qUqHuO00025QrE$V" GlobalId="3lv5i0qUqHuO00025QrE$V" Name="PlasticStrain" Description="A measure of the permanent displacement, as in slip or twinning, which remains after the stress has been removed. Currently applied to a strain of 0.2% proportional stress of the material." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="PlateType_1k0KQdYJT4WhtMu_7lyRTR" GlobalId="1k0KQdYJT4WhtMu_7lyRTR" Name="PlateType" Description="Type of bolt plate used." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="PlayerMediaEject_0I5BE0qSCHuO00025QrE$V" GlobalId="0I5BE0qSCHuO00025QrE$V" Name="PlayerMediaEject" Description="Indicates whether the media can be ejected from the player (if physical media)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="PlayerMediaFormat_0Oeoi0qSCHuO00025QrE$V" GlobalId="0Oeoi0qSCHuO00025QrE$V" Name="PlayerMediaFormat" Description="Indicates supported media formats." TemplateType="p_tablevalue" PrimaryMeasureType="IfcIdentifier" SecondaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="PlayerType_04zyI0qSCHuO00025QrE$V" GlobalId="04zyI0qSCHuO00025QrE$V" Name="PlayerType" Description="Indicates the type of player." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_AudioVisualPlayerType">
						<EnumerationValues>
							<IfcLabel-wrapper>AUDIO</IfcLabel-wrapper>
							<IfcLabel-wrapper>VIDEO</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Plies_1ZXcW0qUuHuO00025QrE$V" GlobalId="1ZXcW0qUuHuO00025QrE$V" Name="Plies" Description="Number of plies." TemplateType="p_singlevalue" PrimaryMeasureType="IfcInteger" />
				<IfcSimplePropertyTemplate id="Plunge_0jANEsqIjD28q6omcrafcL" GlobalId="0jANEsqIjD28q6omcrafcL" Name="Plunge" Description="The angle of inclination of the fold axis with the horizontal as measured in a vertical plane." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="PointOfContact_0cDT20qXOHuO00025QrE$V" GlobalId="0cDT20qXOHuO00025QrE$V" Name="PointOfContact" Description="The organization that should be contacted for action under the terms of the warranty. Note that the role of the organization (manufacturer, supplier, installer etc.) is determined by the IfcActorRole attribute of IfcOrganization." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="PoisonsRatio_3ZGJpY849AUhml6K4M4C95" GlobalId="3ZGJpY849AUhml6K4M4C95" Name="PoisonsRatio" Description="Ratio of transverse contraction strain to longitudinal extension strain in the direction of stretching force." TemplateType="p_singlevalue" PrimaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="PoissonRatio_25Cn_0qUqHuO00025QrE$V" GlobalId="25Cn_0qUqHuO00025QrE$V" Name="PoissonRatio" Description="A measure of the lateral deformations in the elastic range." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="Polarity_0dswO0qSuHuO00025QrE$V" GlobalId="0dswO0qSuHuO00025QrE$V" Name="Polarity" Description="True indicates normal polarity; False indicates reverse polarity." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="PolarizationMode_0xnVcngeL0puq0IO2aWcNm" GlobalId="0xnVcngeL0puq0IO2aWcNm" Name="PolarizationMode" Description="Indicates the polarization mode of antenna." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_PolarizationMode">
						<EnumerationValues>
							<IfcLabel-wrapper>DUALPOLARIZATION</IfcLabel-wrapper>
							<IfcLabel-wrapper>SINGLEPOLARIZATION</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="PolarizationModeDispersionTolerance_1l9fqAQsz5qR9XY_Mh244N" GlobalId="1l9fqAQsz5qR9XY_Mh244N" Name="PolarizationModeDispersionTolerance" Description="Indicates the polarization mode dispersion tolerance of the transport equipment. It is usually measured by picosecond." TemplateType="p_singlevalue" PrimaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="PoleUsage_2a8qh0dWHD9OWx5IdbYOLq" GlobalId="2a8qh0dWHD9OWx5IdbYOLq" Name="PoleUsage" Description="Pole usage." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_PoleUsage">
						<EnumerationValues>
							<IfcLabel-wrapper>1P</IfcLabel-wrapper>
							<IfcLabel-wrapper>2P</IfcLabel-wrapper>
							<IfcLabel-wrapper>3P</IfcLabel-wrapper>
							<IfcLabel-wrapper>4P</IfcLabel-wrapper>
							<IfcLabel-wrapper>1PN</IfcLabel-wrapper>
							<IfcLabel-wrapper>3PN</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Porosity_2iu_CiIPj8UepXPOfjNQfw" GlobalId="2iu_CiIPj8UepXPOfjNQfw" Name="Porosity" Description="The volumetric fraction of pores in the material." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="Porosity_3OMAA0qUmHuO00025QrE$V" GlobalId="3OMAA0qUmHuO00025QrE$V" Name="Porosity" Description="The void fraction of the total volume occupied by material (Vbr - Vnet)/Vbr." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="PortCapacity_2wGIZukqb5y8_rmxPBWB8h" GlobalId="2wGIZukqb5y8_rmxPBWB8h" Name="PortCapacity" Description="Indicates the number of ports in the passive device that can be used to interconnect cables." TemplateType="p_singlevalue" PrimaryMeasureType="IfcInteger" />
				<IfcSimplePropertyTemplate id="PortNumber_30TII0qTGHuO00025QrE$V" GlobalId="30TII0qTGHuO00025QrE$V" Name="PortNumber" Description="The port index for logically ordering the port within the containing element or element type." TemplateType="p_singlevalue" PrimaryMeasureType="IfcInteger" />
				<IfcSimplePropertyTemplate id="PositionHistory_0Mrca0qRqHuO00025QrE$V" GlobalId="0Mrca0qRqHuO00025QrE$V" Name="PositionHistory" Description="Indicates position of the actuator over time where 0.0 is fully closed and 1.0 is fully open." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="PositionInTrack_2$JKUv68rC$QfoodxwEHNq" GlobalId="2$JKUv68rC$QfoodxwEHNq" Name="PositionInTrack" Description="Indicates the relative position of the element in track, which lies to the left or right as facing in the direction of increasing stationing values." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i1721" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="PostalBox_0tUIthihvEUR0uX5WlybVY" GlobalId="0tUIthihvEUR0uX5WlybVY" Name="PostalBox" Description="An address that is implied by an identifiable mail drop." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="PostalCode_0nTJvBq39DDxmEozSIwMR6" GlobalId="0nTJvBq39DDxmEozSIwMR6" Name="PostalCode" Description="The code that is used by the country&apos;s postal service." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="Power_13VYb5tj10cOr5hZsTbt3R" GlobalId="13VYb5tj10cOr5hZsTbt3R" Name="Power" Description="The actual power and operable range." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="PowerCapacity_1mAfVHVQfDtBcb3$W2OBiX" GlobalId="1mAfVHVQfDtBcb3$W2OBiX" Name="PowerCapacity" Description="Power capacity of the equipment" TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricChargeMeasure" />
				<IfcSimplePropertyTemplate id="PowerDemand_1FaUfs_7b2qQdwXAs_k3m$" GlobalId="1FaUfs_7b2qQdwXAs_k3m$" Name="PowerDemand" Description="Power demand of the element" TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="PowerDissipation_3UBu01JHrASAEoqzhOMsSb" GlobalId="3UBu01JHrASAEoqzhOMsSb" Name="PowerDissipation" Description="Permissible power which may be dissipated continuously, at specified conditions." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="PowerFactor_3FKZGrWnL47wR1V9jblsAW" GlobalId="3FKZGrWnL47wR1V9jblsAW" Name="PowerFactor" Description="Power factor; usually as ratio.

The ratio between the rated electrical power and the product of the rated current and rated voltage" TemplateType="p_singlevalue" PrimaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="PowerFactorHistory_1Jv3lEllLAG9RzY6AaK90z" GlobalId="1Jv3lEllLAG9RzY6AaK90z" Name="PowerFactorHistory" Description="Power factor." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="PowerHistory_2sQ1k0qVuHuO00025QrE$V" GlobalId="2sQ1k0qVuHuO00025QrE$V" Name="PowerHistory" Description="The actual power consumption of the pump." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="PowerLoss_15mFy0qVuHuO00025QrE$V" GlobalId="15mFy0qVuHuO00025QrE$V" Name="PowerLoss" Description="The power loss in [W].

The power loss in [W] of the fuse when the nominal current is flowing through the fuse." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="PowerLoss_17rkswZN5Ayh1V1zbea9$s" GlobalId="17rkswZN5Ayh1V1zbea9$s" Name="PowerLoss" Description="The power loss in [W].

Total loss of power across this cable." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="PowerLoss_24e8O0qVaHuO00025QrE$V" GlobalId="24e8O0qVaHuO00025QrE$V" Name="PowerLoss" Description="The power loss in [W].

The power loss in [W] per pole of the MCB when the nominal current is flowing through the MCB." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="PowerSource_0dZTk0qSiHuO00025QrE$V" GlobalId="0dZTk0qSiHuO00025QrE$V" Name="PowerSource" Description="Type of power driving the compressor." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_CompressorTypePowerSource">
						<EnumerationValues>
							<IfcLabel-wrapper>MOTORDRIVEN</IfcLabel-wrapper>
							<IfcLabel-wrapper>ENGINEDRIVEN</IfcLabel-wrapper>
							<IfcLabel-wrapper>GASTURBINE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="PowerState_1nWBo0qTyHuO00025QrE$V" GlobalId="1nWBo0qTyHuO00025QrE$V" Name="PowerState" Description="Indicates the power state of the device where True is on and False is off." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="PowerState_2GmHy0qSeHuO00025QrE$V" GlobalId="2GmHy0qSeHuO00025QrE$V" Name="PowerState" Description="Indicates the power state of the device where True is on and False is off." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="PowerState_2z96s0qS4HuO00025QrE$V" GlobalId="2z96s0qS4HuO00025QrE$V" Name="PowerState" Description="Indicates the power state of the device where True is on and False is off." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="PowerSupplyMode_0R5br9ai188vK3YgXwAZkg" GlobalId="0R5br9ai188vK3YgXwAZkg" Name="PowerSupplyMode" Description="Power supply mode of the equipment or system." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_PowerSupplyMode">
						<EnumerationValues>
							<IfcLabel-wrapper>AC</IfcLabel-wrapper>
							<IfcLabel-wrapper>DC</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Pressure_1rWyryNgTD49uhQjRGslfB" GlobalId="1rWyryNgTD49uhQjRGslfB" Name="Pressure" Description="The pressure of fluid." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="Pressure_3CIho6yXrEuwXjE1K1d5gp" GlobalId="3CIho6yXrEuwXjE1K1d5gp" Name="Pressure" Description="The pressure of the fluid." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="PressureClass_0M0Vy0qTuHuO00025QrE$V" GlobalId="0M0Vy0qTuHuO00025QrE$V" Name="PressureClass" Description="Nominal pressure rating of the object.

Pressure classification as defined by the authority having jurisdiction (e.g., SMACNA, etc.)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="PressureClass_0MyLk0qVCHuO00025QrE$V" GlobalId="0MyLk0qVCHuO00025QrE$V" Name="PressureClass" Description="Nominal pressure rating of the object.

The test or rated pressure classification of the fitting." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="PressureClass_3EBQY0qTeHuO00025QrE$V" GlobalId="3EBQY0qTeHuO00025QrE$V" Name="PressureClass" Description="Nominal pressure rating of the object.

Nominal pressure rating of the system components." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="PressureCurve_2csza0qUGHuO00025QrE$V" GlobalId="2csza0qUGHuO00025QrE$V" Name="PressureCurve" Description="Pressure rise = f (flow rate)." TemplateType="p_tablevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" SecondaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="PressureDrop_0wcgw0qRyHuO00025QrE$V" GlobalId="0wcgw0qRyHuO00025QrE$V" Name="PressureDrop" Description="Pressure drop.

Drop in total pressure between inlet and outlet at nominal air-flow rate." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="PressureDrop_39$8s0qT0HuO00025QrE$V" GlobalId="39$8s0qT0HuO00025QrE$V" Name="PressureDrop" Description="Pressure drop." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="PressureDropCurve_2FwRQ0qUKHuO00025QrE$V" GlobalId="2FwRQ0qUKHuO00025QrE$V" Name="PressureDropCurve" Description="Under certain dust holding weight, DelPressure = f (fluidflowRate)" TemplateType="p_tablevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" SecondaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="PressureGaugeType_2ydis0qUSHuO00025QrE$V" GlobalId="2ydis0qUSHuO00025QrE$V" Name="PressureGaugeType" Description="Identifies the means by which pressure is displayed." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_PressureGaugeType">
						<EnumerationValues>
							<IfcLabel-wrapper>DIAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>DIGITAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>MANOMETER</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="PressureHistory_21I6029$T09OOx3TehMZSk" GlobalId="21I6029$T09OOx3TehMZSk" Name="PressureHistory" Description="The pressure of the fluid." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="PressureLossCoefficient_3IxLy0qT0HuO00025QrE$V" GlobalId="3IxLy0qT0HuO00025QrE$V" Name="PressureLossCoefficient" Description="Pressure loss coefficient." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="PressuremeterType_1y3JjznIn4hQPFaA5mCFy3" GlobalId="1y3JjznIn4hQPFaA5mCFy3" Name="PressuremeterType" Description="Indication of the type of equipment used for the pressuremeter test." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="PressureRange_0QnhC0qTuHuO00025QrE$V" GlobalId="0QnhC0qTuHuO00025QrE$V" Name="PressureRange" Description="Allowable maximum and minimum working pressure (relative to ambient pressure)." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="PressureRange_0SJgO0qVCHuO00025QrE$V" GlobalId="0SJgO0qVCHuO00025QrE$V" Name="PressureRange" Description="Allowable maximum and minimum working pressure (relative to ambient pressure)." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="PressureRange_2HOx20qTuHuO00025QrE$V" GlobalId="2HOx20qTuHuO00025QrE$V" Name="PressureRange" Description="Allowable maximum and minimum working pressure (relative to ambient pressure)." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="PressureRange_2jlXW0qVCHuO00025QrE$V" GlobalId="2jlXW0qVCHuO00025QrE$V" Name="PressureRange" Description="Allowable maximum and minimum working pressure (relative to ambient pressure)." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="PressureRating_1rwwm0qSGHuO00025QrE$V" GlobalId="1rwwm0qSGHuO00025QrE$V" Name="PressureRating" Description="Pressure rating of the object.

Nominal pressure rating of the boiler as rated by the agency having jurisdiction." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="PressureRating_2sN260qUOHuO00025QrE$V" GlobalId="2sN260qUOHuO00025QrE$V" Name="PressureRating" Description="Pressure rating of the object.

Maximum pressure that the hydrant is manufactured to withstand." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="PressureRegulatorSetting_1Q3VU0qX0HuO00025QrE$V" GlobalId="1Q3VU0qX0HuO00025QrE$V" Name="PressureRegulatorSetting" Description="Pressure that is automatically maintained in the tank." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="PressureRegulatorSetting_2fxBw0qX0HuO00025QrE$V" GlobalId="2fxBw0qX0HuO00025QrE$V" Name="PressureRegulatorSetting" Description="Pressure that is automatically maintained in the tank." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="PressureRise_2jTqe0qVuHuO00025QrE$V" GlobalId="2jTqe0qVuHuO00025QrE$V" Name="PressureRise" Description="The developed pressure." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="PreStress_1AeV_jgFf4lQ6cpFxp6xKo" GlobalId="1AeV_jgFf4lQ6cpFxp6xKo" Name="PreStress" Description="The prestress to be applied on the tendon." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="PreSupportLocation_2iM5GiTq558OyAc6GsixWz" GlobalId="2iM5GiTq558OyAc6GsixWz" Name="PreSupportLocation" Description="Specifies whether the pre-support is in face or around circumference." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_PreSupportLocation">
						<EnumerationValues>
							<IfcLabel-wrapper>TUNNELVAULT</IfcLabel-wrapper>
							<IfcLabel-wrapper>TUNNELFACE</IfcLabel-wrapper>
							<IfcLabel-wrapper>USERDEFINED</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTDEFINED</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="PreSupportType_2ThVWCaSXFCOlQAjGqDSIe" GlobalId="2ThVWCaSXFCOlQAjGqDSIe" Name="PreSupportType" Description="Specifies the type of pre-support applied." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_PreSupportType">
						<EnumerationValues>
							<IfcLabel-wrapper>JETGROUTED</IfcLabel-wrapper>
							<IfcLabel-wrapper>PIPEUMBRELLA</IfcLabel-wrapper>
							<IfcLabel-wrapper>FREEZING</IfcLabel-wrapper>
							<IfcLabel-wrapper>FOREPOLING</IfcLabel-wrapper>
							<IfcLabel-wrapper>SPILING</IfcLabel-wrapper>
							<IfcLabel-wrapper>USERDEFINED</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTDEFINED</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="PreTensionAim_3aicuu8QP28AAdbn5w7Vos" GlobalId="3aicuu8QP28AAdbn5w7Vos" Name="PreTensionAim" Description="Line force that the winch is set to maintain (minimum load)" TemplateType="p_singlevalue" PrimaryMeasureType="IfcForceMeasure" />
				<IfcSimplePropertyTemplate id="PrevailingWindDirection_0dxPq0qV8HuO00025QrE$V" GlobalId="0dxPq0qV8HuO00025QrE$V" Name="PrevailingWindDirection" Description="The prevailing wind angle direction measured from True North (0 degrees) in a clockwise direction." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="PrevailingWindVelocity_0jIkU0qV8HuO00025QrE$V" GlobalId="0jIkU0qV8HuO00025QrE$V" Name="PrevailingWindVelocity" Description="The design wind velocity coming from the direction specified by the PrevailingWindDirection attribute." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLinearVelocityMeasure" />
				<IfcSimplePropertyTemplate id="PrimaryAirFlowRateRange_3Hj3O0qS0HuO00025QrE$V" GlobalId="3Hj3O0qS0HuO00025QrE$V" Name="PrimaryAirFlowRateRange" Description="Possible range of primary airflow that can be delivered." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="PrimaryApparentPower_23UrC0qX4HuO00025QrE$V" GlobalId="23UrC0qX4HuO00025QrE$V" Name="PrimaryApparentPower" Description="The power in VA (volt ampere) that has been transformed and that runs into the transformer on the primary side." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="PrimaryCurrent_1gSg80qX4HuO00025QrE$V" GlobalId="1gSg80qX4HuO00025QrE$V" Name="PrimaryCurrent" Description="The current that is going to be transformed and that runs into the transformer on the primary side." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="PrimaryEnergyConsumption_1PJtG0qSGHuO00025QrE$V" GlobalId="1PJtG0qSGHuO00025QrE$V" Name="PrimaryEnergyConsumption" Description="Boiler primary energy source consumption (i.e., the fuel consumed for changing the thermodynamic state of the fluid)." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="PrimaryFrequency_1tZv40qX4HuO00025QrE$V" GlobalId="1tZv40qX4HuO00025QrE$V" Name="PrimaryFrequency" Description="The frequency that is going to be transformed and that runs into the transformer on the primary side." TemplateType="p_singlevalue" PrimaryMeasureType="IfcFrequencyMeasure" />
				<IfcSimplePropertyTemplate id="PrimaryProductionType_0V_$0qqDn9Tf1PLPQjjK_e" GlobalId="0V_$0qqDn9Tf1PLPQjjK_e" Name="PrimaryProductionType" Description="Primary type of ship production of the facility" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="PrimarySurfaceArea_0L_0G0qSeHuO00025QrE$V" GlobalId="0L_0G0qSeHuO00025QrE$V" Name="PrimarySurfaceArea" Description="Primary heat transfer surface area of the tubes and headers." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAreaMeasure" />
				<IfcSimplePropertyTemplate id="PrimaryVoltage_1Txac0qX4HuO00025QrE$V" GlobalId="1Txac0qX4HuO00025QrE$V" Name="PrimaryVoltage" Description="The voltage that is going to be transformed and that runs into the transformer on the primary side." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricVoltageMeasure" />
				<IfcSimplePropertyTemplate id="Process_3VUxA0qUGHuO00025QrE$V" GlobalId="3VUxA0qUGHuO00025QrE$V" Name="Process" Description="Reference number of the welding process according to ISO 4063, an up to three digits long code" TemplateType="p_singlevalue" PrimaryMeasureType="IfcInteger" />
				<IfcSimplePropertyTemplate id="ProcessCapacity_1lMQMfyaj8WukwZC4nXkfi" GlobalId="1lMQMfyaj8WukwZC4nXkfi" Name="ProcessCapacity" Description="The number of units that can be processed in the time defined in ProcessPerformance" TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="ProcessDirection_0_iuQ9laT8WBnP5Q4o04AH" GlobalId="0_iuQ9laT8WBnP5Q4o04AH" Name="ProcessDirection" Description="The direction of flow of the cargo within the process." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ProcessDirection">
						<EnumerationValues>
							<IfcLabel-wrapper>IMPORT</IfcLabel-wrapper>
							<IfcLabel-wrapper>EXPORT</IfcLabel-wrapper>
							<IfcLabel-wrapper>TRANSFER</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ProcessItem_0yXM2dwTn71gpxHeftzb$S" GlobalId="0yXM2dwTn71gpxHeftzb$S" Name="ProcessItem" Description="The type of item (and its measurement method) being modelled within a process. This can be cargo, passengers or vehicles that pass through the system." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ProcessItem">
						<EnumerationValues>
							<IfcLabel-wrapper>TEU</IfcLabel-wrapper>
							<IfcLabel-wrapper>CGT</IfcLabel-wrapper>
							<IfcLabel-wrapper>BARREL</IfcLabel-wrapper>
							<IfcLabel-wrapper>TONNE</IfcLabel-wrapper>
							<IfcLabel-wrapper>PASSENGER</IfcLabel-wrapper>
							<IfcLabel-wrapper>VEHICLE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ProcessName_3asFq0qUGHuO00025QrE$V" GlobalId="3asFq0qUGHuO00025QrE$V" Name="ProcessName" Description="Name of the welding process. Alternative to the numeric Process property." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ProcessPerformance_2nqNIMRDj0LAY1mI3ZvbZH" GlobalId="2nqNIMRDj0LAY1mI3ZvbZH" Name="ProcessPerformance" Description="Minimum time to accept or dispatch the entire item capacity." TemplateType="p_singlevalue" PrimaryMeasureType="IfcDuration" />
				<IfcSimplePropertyTemplate id="ProcurementMethod_0HZB4plKf1oOsbtTq1O1Zs" GlobalId="0HZB4plKf1oOsbtTq1O1Zs" Name="ProcurementMethod" Description="The method by which an IfcProductType/IfcProduct is acquired and installed. The value provided shall be one of the following four character acronyms: “CFCI” (meaning Contractor Furnished Contractor Installed), “OFCI” (meaning Owner Furnished Contractor Installed), or “OFOI” (meaning Owner Furnished Owner Installed)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ProductDescription_1Jlr60qVSHuO00025QrE$V" GlobalId="1Jlr60qVSHuO00025QrE$V" Name="ProductDescription" Description="A textual description of the products that require the work." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="ProductDescription_3_DtI0qVSHuO00025QrE$V" GlobalId="3_DtI0qVSHuO00025QrE$V" Name="ProductDescription" Description="A textual description of the products that require the work." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="ProductionLotId_13MQU0qVGHuO00025QrE$V" GlobalId="13MQU0qVGHuO00025QrE$V" Name="ProductionLotId" Description="The manufacturer&apos;s production lot identifier." TemplateType="p_singlevalue" PrimaryMeasureType="IfcIdentifier" />
				<IfcSimplePropertyTemplate id="ProductionYear_2OaRi0qUmHuO00025QrE$V" GlobalId="2OaRi0qUmHuO00025QrE$V" Name="ProductionYear" Description="The year of production of the manufactured item." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ProfileType_1AEKQiP7PFbuAGZ6obzmNO" GlobalId="1AEKQiP7PFbuAGZ6obzmNO" Name="ProfileType" Description="Contains a term from a controlled vocabulary specifying the concave/convex geometry of fold relative to earth surface, and relationship to younging direction in folded strata if known (e.g., antiform, synform, neutral, anticline, syncline, monocline, ptygmatic)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcIdentifier" />
				<IfcSimplePropertyTemplate id="ProjectInvestmentEstimate_2HOLtVtqH7xBzdXTbAyiun" GlobalId="2HOLtVtqH7xBzdXTbAyiun" Name="ProjectInvestmentEstimate" Description="Estimate of investment cost" TemplateType="p_referencevalue" PrimaryMeasureType="IfcCostValue" />
				<IfcSimplePropertyTemplate id="ProjectorType_0ekmg0qSCHuO00025QrE$V" GlobalId="0ekmg0qSCHuO00025QrE$V" Name="ProjectorType" Description="Indicates the type of projector." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_AudioVisualProjectorType">
						<EnumerationValues>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ProjectType_2$S70iKB11wRZELFihKhH7" GlobalId="2$S70iKB11wRZELFihKhH7" Name="ProjectType" Description="Additional typing of a project" TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ProjectType">
						<EnumerationValues>
							<IfcLabel-wrapper>NEWBUILD</IfcLabel-wrapper>
							<IfcLabel-wrapper>MODIFICATION</IfcLabel-wrapper>
							<IfcLabel-wrapper>REPAIR</IfcLabel-wrapper>
							<IfcLabel-wrapper>OPERATIONMAINTENANCE</IfcLabel-wrapper>
							<IfcLabel-wrapper>RENOVATION</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="PropagationSpeedCoefficient_0AK8i5JmXDxfWTbSTJ3n91" GlobalId="0AK8i5JmXDxfWTbSTJ3n91" Name="PropagationSpeedCoefficient" Description="Indicates the propagation speed coefficient." TemplateType="p_singlevalue" PrimaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="PropertyName_1ZYsM0qVWHuO00025QrE$V" GlobalId="1ZYsM0qVWHuO00025QrE$V" Name="PropertyName" Description="Addressing details of the property as stated within the agreement." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ProportionalConstant_3XXaS0qSqHuO00025QrE$V" GlobalId="3XXaS0qSqHuO00025QrE$V" Name="ProportionalConstant" Description="The proportional gain factor of the controller (usually referred to as Kp)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="ProportionalStress_3fxde0qUqHuO00025QrE$V" GlobalId="3fxde0qUqHuO00025QrE$V" Name="ProportionalStress" Description="A measure of the proportional stress of the material. It describes the stress before the first plastic deformation occurs and is commonly measured at a deformation of 0.01%." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="ProtectivePoreRatio_07RnG0qUqHuO00025QrE$V" GlobalId="07RnG0qUqHuO00025QrE$V" Name="ProtectivePoreRatio" Description="The protective pore ratio indicating the frost-resistance of the concrete." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="Protocols_0LajgwBXH9KgSPIIIBgr3C" GlobalId="0LajgwBXH9KgSPIIIBgr3C" Name="Protocols" Description="For data ports, identifies the protocols used as defined by the Open System Interconnection (OSI) Basic Reference Model (ISO 7498).  Layers include: 1. Physical; 2. DataLink; 3. Network; 4. Transport; 5. Session; 6. Presentation; 7. Application.  Example: 3:IP, 4:TCP, 5:HTTP" TemplateType="p_listvalue" PrimaryMeasureType="IfcIdentifier" />
				<IfcSimplePropertyTemplate id="PubliclyAccessible_0DSku0qWaHuO00025QrE$V" GlobalId="0DSku0qWaHuO00025QrE$V" Name="PubliclyAccessible" Description="Indication whether this space (in case of e.g., a toilet) is designed to serve as a publicly accessible space, e.g., for a public toilet (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="PubliclyAccessible_1AHk40qXaHuO00025QrE$V" GlobalId="1AHk40qXaHuO00025QrE$V" Name="PubliclyAccessible" Description="Indication whether this space (in case of e.g., a toilet) is designed to serve as a publicly accessible space, e.g., for a public toilet (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="PullInVoltage_2dz9sHSqLEL9DJguaAm4sn" GlobalId="2dz9sHSqLEL9DJguaAm4sn" Name="PullInVoltage" Description="Working voltage of relay in excitation state." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricVoltageMeasure" />
				<IfcSimplePropertyTemplate id="PumperConnectionSize_2KOfy0qUOHuO00025QrE$V" GlobalId="2KOfy0qUOHuO00025QrE$V" Name="PumperConnectionSize" Description="The size of a connection to which a fire hose may be connected that is then linked to a pumping unit." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="Purpose_0WRBx2dzz6o8xCwecn3DMi" GlobalId="0WRBx2dzz6o8xCwecn3DMi" Name="Purpose" Description="Indication of the purpose of this object" TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_AddressType">
						<EnumerationValues>
							<IfcLabel-wrapper>DISTRIBUTIONPOINT</IfcLabel-wrapper>
							<IfcLabel-wrapper>HOME</IfcLabel-wrapper>
							<IfcLabel-wrapper>OFFICE</IfcLabel-wrapper>
							<IfcLabel-wrapper>SITE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Purpose_2wsWU0qV4HuO00025QrE$V" GlobalId="2wsWU0qV4HuO00025QrE$V" Name="Purpose" Description="Indication of the purpose of this object

E.g. &apos;ventilation&apos; or &apos;access&apos;" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="PutIntoOperationDate_03cT7VFl92dw8n1GPuqXSv" GlobalId="03cT7VFl92dw8n1GPuqXSv" Name="PutIntoOperationDate" Description="Date on which the element is put into operation." TemplateType="p_singlevalue" PrimaryMeasureType="IfcDate" />
				<IfcSimplePropertyTemplate id="PwaveVelocity_25QNLFrcX23AOU3hgpu9do" GlobalId="25QNLFrcX23AOU3hgpu9do" Name="PwaveVelocity" Description="P-wave velocity of a rock or soil." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLinearVelocityMeasure" />
				<IfcSimplePropertyTemplate id="PwaveVelocity_3PNsA2fgH81Aaey7kS$TDO" GlobalId="3PNsA2fgH81Aaey7kS$TDO" Name="PwaveVelocity" Description="Value of S wave (Shear wave (S)) measured through the unit." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLinearVelocityValue" />
				<IfcSimplePropertyTemplate id="Qvalue_20r43TAl93mwVeOtXNHvj4" GlobalId="20r43TAl93mwVeOtXNHvj4" Name="Q-value" Description="A description of the rock mass stability of an underground opening in jointed rock masses based on Q-system which was originaly developed at NGI.2015 - Handbook on the Q-System - NGI." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="Quality_0Cl6Q0qSqHuO00025QrE$V" GlobalId="0Cl6Q0qSqHuO00025QrE$V" Name="Quality" Description="Indicates the quality of measurement or failure condition, which may be further qualified by the Status. True: measured values are considered reliable; False: measured values are considered not reliable (i.e. a fault has been detected); Unknown: reliability of values is uncertain." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcLogical" />
				<IfcSimplePropertyTemplate id="Quality_2Khse0qUSHuO00025QrE$V" GlobalId="2Khse0qUSHuO00025QrE$V" Name="Quality" Description="Indicates the quality of measurement or failure condition, which may be further qualified by the Status. True: measured values are considered reliable; False: measured values are considered not reliable (i.e. a fault has been detected); Unknown: reliability of values is uncertain." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcLogical" />
				<IfcSimplePropertyTemplate id="Quality_3R_2E0qWGHuO00025QrE$V" GlobalId="3R_2E0qWGHuO00025QrE$V" Name="Quality" Description="Indicates the quality of measurement or failure condition, which may be further qualified by the Status. True: measured values are considered reliable; False: measured values are considered not reliable (i.e. a fault has been detected); Unknown: reliability of values is uncertain." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcLogical" />
				<IfcSimplePropertyTemplate id="QualityHistory_1z_Gs375PED9dAUPht8BFC" GlobalId="1z_Gs375PED9dAUPht8BFC" Name="QualityHistory" Description="Indicates the quality of measurement or failure condition, which may be further qualified by the Status.  True: measured values are considered reliable; False: measured values are considered not reliable (i.e. a fault has been detected); Unknown: reliability of values is uncertain." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcLogical" />
				<IfcSimplePropertyTemplate id="QualityOfComponents_3LzIU75Rv2eBKvppy605JZ" GlobalId="3LzIU75Rv2eBKvppy605JZ" Name="QualityOfComponents" Description="Adjustment of the service life resulting from the effect of the quality of components used." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="QuaySectionType_1NgIfYZRT9j8NN6lJ2fnxX" GlobalId="1NgIfYZRT9j8NN6lJ2fnxX" Name="QuaySectionType" Description="Whether the structure presents a solid/closed barrier to the passage of water or is open." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i2468" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="QValue_1bhEISWbXCwxu8IMpl$sWn" GlobalId="1bhEISWbXCwxu8IMpl$sWn" Name="QValue" Description="The rock mass quality (Q) is a very sensitive index and its value varies from 0.001 to 1000. Use of the Q-system is specifically recommended for tunnels and caverns with an arched roof.
The Q-value is determined with:
$$
Q = \frac{RQD}{Jn}*\frac{Jr}{Ja}*\frac{Jw}{SRF}
$$
The first term RQD (Rock Quality Designation) divided by Jn (joint set number) is related to the size of the intact rock blocks in the rock mass. The second term Jr (joint roughness number) divided by Ja (joint alteration number) is related to the shear strength along the discontinuity planes and the third term Jw (joint water parameter) divided by SRF (stress reduction factor) is related to the stress environment on the intact rock blocks and discontinuities around the underground excavation.

A multiplication of the three terms results in the Q parameter, which can range between 0.001 for an exceptionally poor to 1000 for an exceptionally good rock mass. The numerical values of the class boundaries for the different rock mass qualities are subdivisions of the Q range on a logarithmic scale." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="QValue_2AP24nbKP3hfI8vdx$uG8T" GlobalId="2AP24nbKP3hfI8vdx$uG8T" Name="QValue" Description="A description of the rock mass stability of an underground opening in jointed rock masses.
&gt;NOTE Definition from Barton, N.R.; Lien, R.; Lunde, J. (1974). Engineering classification of rock masses for the design of tunnel support. Rock Mechanics and Rock Engineering." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="RadialExcavationDepth_1hc8WY5vP3gg1foxh3ure3" GlobalId="1hc8WY5vP3gg1foxh3ure3" Name="RadialExcavationDepth" Description="Depth of radial excavation." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="RadialExcavationDirection_0PWybQDsb7VuLXarptQq0N" GlobalId="0PWybQDsb7VuLXarptQq0N" Name="RadialExcavationDirection" Description="Direction of radial excavation relative to the main tunnel drive." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_RadialExcavationDirection">
						<EnumerationValues>
							<IfcLabel-wrapper>LATERAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>VERTICAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>RADIAL</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="RadialExcavationType_36CrYf_abBQQiXtlkMLup4" GlobalId="36CrYf_abBQQiXtlkMLup4" Name="RadialExcavationType" Description="Type of radial excavation." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_RadialExcavationType">
						<EnumerationValues>
							<IfcLabel-wrapper>PROFILEENLARGEMENT</IfcLabel-wrapper>
							<IfcLabel-wrapper>REPROFILING</IfcLabel-wrapper>
							<IfcLabel-wrapper>NICHE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="RadialExcavationTypeOther_3RsgMwbTP2khfQXrle7GMJ" GlobalId="3RsgMwbTP2khfQXrle7GMJ" Name="RadialExcavationTypeOther" Description="A user defined type of radial excavation when RadialExcavationType = OTHER." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="RadialInclination_27paS9aKT8DPqJm_ip39qg" GlobalId="27paS9aKT8DPqJm_ip39qg" Name="RadialInclination" Description="Inclination measured vs the vertical cross section plane." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="RadialJointConnections_0oSYw0FNv6_xS_Fj6q_a9u" GlobalId="0oSYw0FNv6_xS_Fj6q_a9u" Name="RadialJointConnections" Description="Specified if particular connector, e.g. dowel, is used." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="RadialJointType_0Td7PHpJb2JQKm0I0w16ak" GlobalId="0Td7PHpJb2JQKm0I0w16ak" Name="RadialJointType" Description="Type of radial joint." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i1883" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="RadialSpacing_1TqgA7dOj47v0491hg3bm9" GlobalId="1TqgA7dOj47v0491hg3bm9" Name="RadialSpacing" Description="The distance between the end of the drillholes." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="RadialSpacing_25znbD5O93kQ8QwsBqr1oq" GlobalId="25znbD5O93kQ8QwsBqr1oq" Name="RadialSpacing" Description="Radial spacing between boreholes." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="RadialSpacing_3IFLBXGmnEuu5$jXs$lG3v" GlobalId="3IFLBXGmnEuu5$jXs$lG3v" Name="RadialSpacing" Description="Radial spacing of bolts." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="RadiantFrequency_1TRSUYI_166AUFrlaZw$TZ" GlobalId="1TRSUYI_166AUFrlaZw$TZ" Name="RadiantFrequency" Description="Indicates the radiant frequency of the leaky coaxial cable (radiating cable)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcFrequencyMeasure" />
				<IfcSimplePropertyTemplate id="RadiatedOutputPowerPerAntenna_1uH9Rio6XFy8Z6EBj1Yjbb" GlobalId="1uH9Rio6XFy8Z6EBj1Yjbb" Name="RadiatedOutputPowerPerAntenna" Description="Indicates the power of radio waves emitted by each antenna of the base transceiver station." TemplateType="p_tablevalue" PrimaryMeasureType="IfcLabel" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="RadiationPattern_0KBK4$FZP5memrgigaPaRn" GlobalId="0KBK4$FZP5memrgigaPaRn" Name="RadiationPattern" Description="Indicates the radiation pattern of antenna." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_RadiationPattern">
						<EnumerationValues>
							<IfcLabel-wrapper>DIRECTIONAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>OMNIDIRECTIONAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>FANBEAM</IfcLabel-wrapper>
							<IfcLabel-wrapper>PENCILBEAM</IfcLabel-wrapper>
							<IfcLabel-wrapper>SHAPEDBEAM</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="RadiatorType_2HUQM0qWeHuO00025QrE$V" GlobalId="2HUQM0qWeHuO00025QrE$V" Name="RadiatorType" Description="Indicates the type of radiator." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_SpaceHeaterRadiatorType">
						<EnumerationValues>
							<IfcLabel-wrapper>FINNEDTUBE</IfcLabel-wrapper>
							<IfcLabel-wrapper>PANEL</IfcLabel-wrapper>
							<IfcLabel-wrapper>SECTIONAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>TUBULAR</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="RadioactiveWaste_0xaGU0qU8HuO00025QrE$V" GlobalId="0xaGU0qU8HuO00025QrE$V" Name="RadioactiveWaste" Description="Quantity of radioactive waste generated." TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassMeasure" />
				<IfcSimplePropertyTemplate id="RadioactiveWastePerUnit_3cxOo0qU4HuO00025QrE$V" GlobalId="3cxOo0qU4HuO00025QrE$V" Name="RadioactiveWastePerUnit" Description="Quantity of radioactive waste generated" TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassMeasure" />
				<IfcSimplePropertyTemplate id="Radius_2591D4Lin3Jhrrps1RS0JX" GlobalId="2591D4Lin3Jhrrps1RS0JX" Name="Radius" Description="The radius of the object. The size information is provided in addition to the shape representation and the geometric parameters used within. In cases of inconsistency between the geometric parameters and the size properties, provided in the attached property set, the geometric parameters take precedence." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="RailCondition_1GKMqOWo538xJ6QcnnKJnb" GlobalId="1GKMqOWo538xJ6QcnnKJnb" Name="RailCondition" Description="Assessment of the condition of the rail at point of installation." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_RailCondition">
						<EnumerationValues>
							<IfcLabel-wrapper>NEWRAIL</IfcLabel-wrapper>
							<IfcLabel-wrapper>REGENERATEDRAIL</IfcLabel-wrapper>
							<IfcLabel-wrapper>REUSEDRAIL</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="RailDeliveryState_36$bpzasz7Wwt383_gPDf3" GlobalId="36$bpzasz7Wwt383_gPDf3" Name="RailDeliveryState" Description="The delivery state of rail, which indicates the final treatment at the end in manufacturing." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_RailDeliveryState">
						<EnumerationValues>
							<IfcLabel-wrapper>HOTROLLING</IfcLabel-wrapper>
							<IfcLabel-wrapper>HEATTREATMENT</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="RailElementaryLength_139zI2nWv5vuRYYFkrBt5t" GlobalId="139zI2nWv5vuRYYFkrBt5t" Name="RailElementaryLength" Description="The standardised length of rail supplied from the manufacturer." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_RailElementaryLength">
						<EnumerationValues>
							<IfcLabel-wrapper>6M</IfcLabel-wrapper>
							<IfcLabel-wrapper>75M</IfcLabel-wrapper>
							<IfcLabel-wrapper>100M</IfcLabel-wrapper>
							<IfcLabel-wrapper>108M</IfcLabel-wrapper>
							<IfcLabel-wrapper>120M</IfcLabel-wrapper>
							<IfcLabel-wrapper>144M</IfcLabel-wrapper>
							<IfcLabel-wrapper>400M</IfcLabel-wrapper>
							<IfcLabel-wrapper>30M</IfcLabel-wrapper>
							<IfcLabel-wrapper>60M</IfcLabel-wrapper>
							<IfcLabel-wrapper>72M</IfcLabel-wrapper>
							<IfcLabel-wrapper>12M</IfcLabel-wrapper>
							<IfcLabel-wrapper>18M</IfcLabel-wrapper>
							<IfcLabel-wrapper>24M</IfcLabel-wrapper>
							<IfcLabel-wrapper>25M</IfcLabel-wrapper>
							<IfcLabel-wrapper>27M</IfcLabel-wrapper>
							<IfcLabel-wrapper>36M</IfcLabel-wrapper>
							<IfcLabel-wrapper>48M</IfcLabel-wrapper>
							<IfcLabel-wrapper>54M</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="RailGap_0$Ooq6bAz7GfDzJmMijf3H" GlobalId="0$Ooq6bAz7GfDzJmMijf3H" Name="RailGap" Description="The gap between the rail profiles." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="RailPadStiffness_26aYV31ZvC_QTcssV9r4Tb" GlobalId="26aYV31ZvC_QTcssV9r4Tb" Name="RailPadStiffness" Description="Indicates the stiffness of a rail pad." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_RailPadStiffness">
						<EnumerationValues>
							<IfcLabel-wrapper>STIFF</IfcLabel-wrapper>
							<IfcLabel-wrapper>SOFT</IfcLabel-wrapper>
							<IfcLabel-wrapper>MEDIUM</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="RailwayBaliseType_0vpUHwHvz9kAU_7eMQONr9" GlobalId="0vpUHwHvz9kAU_7eMQONr9" Name="RailwayBaliseType" Description="Type of the railway balise." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_RailwayBaliseType">
						<EnumerationValues>
							<IfcLabel-wrapper>ACTIVEBALISE</IfcLabel-wrapper>
							<IfcLabel-wrapper>PASSIVEBALISE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="RailwayCommunicationTerminalType_33g1QhHOT0svusBGtik1jV" GlobalId="33g1QhHOT0svusBGtik1jV" Name="RailwayCommunicationTerminalType" Description="Indicates the type of railway communication terminal." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_RailwayCommunicationTerminalType">
						<EnumerationValues>
							<IfcLabel-wrapper>IP</IfcLabel-wrapper>
							<IfcLabel-wrapper>LEGACY</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="RailwaySignalType_3pasYELxHFsBeUBXC9tocZ" GlobalId="3pasYELxHFsBeUBXC9tocZ" Name="RailwaySignalType" Description="The type of railway signal, e.g. home signal, starting signal, shunting signal, level crossing signal." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_RailwaySignalType">
						<EnumerationValues>
							<IfcLabel-wrapper>DISTANTSIGNAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>APPROACHSIGNAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>HOMESIGNAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>STARTINGSIGNAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>HUMPSIGNAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>SHUNTINGSIGNAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>REPEATINGSIGNAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>OBSTRUCTIONSIGNAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>LEVELCROSSINGSIGNAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>HUMPAUXILIARYSIGANL</IfcLabel-wrapper>
							<IfcLabel-wrapper>BLOCKSIGNAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="RainMeasureRange_16cT3SUBL7WQSBYhySMcyR" GlobalId="16cT3SUBL7WQSBYhySMcyR" Name="RainMeasureRange" Description="Indicates the measuring range of rain gauge." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="RainSensorType_1UG6PIKkT84uhW6B_TLkMI" GlobalId="1UG6PIKkT84uhW6B_TLkMI" Name="RainSensorType" Description="Indicates the type of rain sensor or gauge." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_RainSensorType">
						<EnumerationValues>
							<IfcLabel-wrapper>MICROWAVE</IfcLabel-wrapper>
							<IfcLabel-wrapper>PIEZOELECTRIC</IfcLabel-wrapper>
							<IfcLabel-wrapper>TIPPINGBUCKET</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="RaisedCompressiveStrength_24vkFVO3zF59eFBHZdlOH3" GlobalId="24vkFVO3zF59eFBHZdlOH3" Name="RaisedCompressiveStrength" Description="Alternative value for compressive strength which may be used under material and code dependent conditions (e.g. if deformation is tolerable, or far from ends of the member); conditions should be stated in SELF\IfcProperty.Description." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="RaisedCompressiveStrength_2QQzGzvunAmPePwQbZoVbQ" GlobalId="2QQzGzvunAmPePwQbZoVbQ" Name="RaisedCompressiveStrength" Description="Alternative value for compressive strength which may be used under material and code dependent conditions (e.g. if deformation is tolerable, or far from ends of the member); conditions should be stated in SELF\IfcProperty.Description." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="RaisedCompressiveStrength_3qR6XMmWnCgvqSxdQ16rVq" GlobalId="3qR6XMmWnCgvqSxdQ16rVq" Name="RaisedCompressiveStrength" Description="Alternative value for compressive strength which may be used under material and code dependent conditions (e.g. if deformation is tolerable, or far from ends of the member); conditions should be stated in SELF\IfcProperty.Description." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="RaisedCompStrengthPerp_04LOOIhZr3DBc$B7zq9dxk" GlobalId="04LOOIhZr3DBc$B7zq9dxk" Name="RaisedCompStrengthPerp" Description="Alternative value for compressive strength, α=90°, which may be used under material and code dependent conditions (e.g. if deformation is tolerable, or far from ends of the member); conditions should be stated in SELF\IfcProperty.Description." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="RaisedCompStrengthPerp_1e6FFTtjLBgOZ8z29e$3k7" GlobalId="1e6FFTtjLBgOZ8z29e$3k7" Name="RaisedCompStrengthPerp" Description="Alternative value for compressive strength, α=90°, which may be used under material and code dependent conditions (e.g. if deformation is tolerable, or far from ends of the member); conditions should be stated in SELF\IfcProperty.Description." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="RaisedCompStrengthPerp_3RBkeZwQr0rx9ofkNqvpwS" GlobalId="3RBkeZwQr0rx9ofkNqvpwS" Name="RaisedCompStrengthPerp" Description="Alternative value for compressive strength, α=90°, which may be used under material and code dependent conditions (e.g. if deformation is tolerable, or far from ends of the member); conditions should be stated in SELF\IfcProperty.Description." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="Range_1U$OU0qSqHuO00025QrE$V" GlobalId="1U$OU0qSqHuO00025QrE$V" Name="Range" Description="The physical range of values supported by the device." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="RangeAngle_2uzb40qRqHuO00025QrE$V" GlobalId="2uzb40qRqHuO00025QrE$V" Name="RangeAngle" Description="Indicates the maximum rotation the actuator must traverse." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="Rank_2nKOcVn1PD5Arvkf8nGOWd" GlobalId="2nKOcVn1PD5Arvkf8nGOWd" Name="Rank" Description="&gt;NOTE Definition according to ISC: The rank of GeologicUnit e.g., group, formation, member." TemplateType="p_singlevalue" PrimaryMeasureType="IfcIdentifier" />
				<IfcSimplePropertyTemplate id="RatedCapacitance_2Kimec$1fFleqiGj$Fg9HN" GlobalId="2Kimec$1fFleqiGj$Fg9HN" Name="RatedCapacitance" Description="Capacitance value determined under specified conditions and declared by the manufacturer." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCapacitanceMeasure" />
				<IfcSimplePropertyTemplate id="RatedCurrent_1uJPqXHDH0jRCEAj47O9L8" GlobalId="1uJPqXHDH0jRCEAj47O9L8" Name="RatedCurrent" Description="The current that a device is designed to handle." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="RatedFrequency_0xk7ZvULjDVACUV9Qs5Q4T" GlobalId="0xk7ZvULjDVACUV9Qs5Q4T" Name="RatedFrequency" Description="Frequency of the AC electric power supply when the device or system reaches its optimum operating condition." TemplateType="p_singlevalue" PrimaryMeasureType="IfcFrequencyMeasure" />
				<IfcSimplePropertyTemplate id="RatedFrequency_2e0YIS0SP8ffTho62YkBSL" GlobalId="2e0YIS0SP8ffTho62YkBSL" Name="RatedFrequency" Description="Frequency of the AC electric power supply when the device or system reaches its optimum operating condition." TemplateType="p_singlevalue" PrimaryMeasureType="IfcFrequencyMeasure" />
				<IfcSimplePropertyTemplate id="RatedTemperature_1$TnC0qSWHuO00025QrE$V" GlobalId="1$TnC0qSWHuO00025QrE$V" Name="RatedTemperature" Description="The range of allowed temperature that a device is certified to handle. The upper bound of this value is the maximum." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="RatedTemperature_14mAi0qSSHuO00025QrE$V" GlobalId="14mAi0qSSHuO00025QrE$V" Name="RatedTemperature" Description="The range of allowed temperature that a device is certified to handle. The upper bound of this value is the maximum." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="RatedVoltage_0_oie0qSSHuO00025QrE$V" GlobalId="0_oie0qSSHuO00025QrE$V" Name="RatedVoltage" Description="The range of allowed voltage that a device is certified to handle. The upper bound of this value is the maximum." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcElectricVoltageMeasure" />
				<IfcSimplePropertyTemplate id="RatedVoltage_1uw9k0qSWHuO00025QrE$V" GlobalId="1uw9k0qSWHuO00025QrE$V" Name="RatedVoltage" Description="The range of allowed voltage that a device is certified to handle. The upper bound of this value is the maximum." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcElectricVoltageMeasure" />
				<IfcSimplePropertyTemplate id="RatedVoltage_2YuL_rvIv9uxXdCK0Vu7_6" GlobalId="2YuL_rvIv9uxXdCK0Vu7_6" Name="RatedVoltage" Description="The range of allowed voltage that a device is certified to handle. The upper bound of this value is the maximum." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcElectricVoltageMeasure" />
				<IfcSimplePropertyTemplate id="RatedVoltageRange_2Yd6MqG2nFieRrEL44q9kc" GlobalId="2Yd6MqG2nFieRrEL44q9kc" Name="RatedVoltageRange" Description="Voltage range as declared by the manufacturer expressed by its lower and upper rated voltages [Source : IEC 62368-1:2010, 3.3.10.5]." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcElectricVoltageMeasure" />
				<IfcSimplePropertyTemplate id="RateOfTemperatureRise_2C$hu0qWKHuO00025QrE$V" GlobalId="2C$hu0qWKHuO00025QrE$V" Name="RateOfTemperatureRise" Description="The rate of temperature rise that is to be sensed as being hazardous." TemplateType="p_singlevalue" PrimaryMeasureType="IfcTemperatureRateOfChangeMeasure" />
				<IfcSimplePropertyTemplate id="RatioOfWireTension_3jOIIDu3fDzgwbbcxO3kVC" GlobalId="3jOIIDu3fDzgwbbcxO3kVC" Name="RatioOfWireTension" Description="The ratio of wire tension to tensioner weight." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="ReactivePower_107SSt09T8QPi7FlONxs5S" GlobalId="107SSt09T8QPi7FlONxs5S" Name="ReactivePower" Description="Reactive power." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="ReadOutType_0R$Ds0qUWHuO00025QrE$V" GlobalId="0R$Ds0qUWHuO00025QrE$V" Name="ReadOutType" Description="Indication of the form that readout from the meter takes. In the case of a dial read out, this may comprise multiple dials that give a cumulative reading and/or a mechanical odometer." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_MeterReadOutType">
						<EnumerationValues>
							<IfcLabel-wrapper>DIAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>DIGITAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="RealImpedanceRatio_2cfWA0qX4HuO00025QrE$V" GlobalId="2cfWA0qX4HuO00025QrE$V" Name="RealImpedanceRatio" Description="The ratio between the real part of the zero sequence impedance and the real part of the positive impedance (i.e. real part of the short-circuit voltage) of the transformer.
Used for three-phase transformer which includes a N-conductor." TemplateType="p_singlevalue" PrimaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="RealPower_3xhiQ9aS5FZx39O_jb9Gyc" GlobalId="3xhiQ9aS5FZx39O_jb9Gyc" Name="RealPower" Description="Real power." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="ReasonForChange_0uxDq0qVSHuO00025QrE$V" GlobalId="0uxDq0qVSHuO00025QrE$V" Name="ReasonForChange" Description="A description of the problem for why a change is needed." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="ReceiverType_1gIxM0qSCHuO00025QrE$V" GlobalId="1gIxM0qSCHuO00025QrE$V" Name="ReceiverType" Description="Indicates the type of receiver." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_AudioVisualReceiverType">
						<EnumerationValues>
							<IfcLabel-wrapper>AUDIO</IfcLabel-wrapper>
							<IfcLabel-wrapper>AUDIOVIDEO</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ReceptacleLoadIntensity_0ajTc0qX4HuO00025QrE$V" GlobalId="0ajTc0qX4HuO00025QrE$V" Name="ReceptacleLoadIntensity" Description="Average power use intensity of appliances and other non-HVAC equipment in the space per unit area.(PowerMeasure/IfcAreaMeasure)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcHeatFluxDensityMeasure" />
				<IfcSimplePropertyTemplate id="RechargeTime_0t1t$3NL5CXB4ArojrVPpo" GlobalId="0t1t$3NL5CXB4ArojrVPpo" Name="RechargeTime" Description="Recharge time for a rechargable battery." TemplateType="p_singlevalue" PrimaryMeasureType="IfcDuration" />
				<IfcSimplePropertyTemplate id="RecirculatedAir_2N8xi0qWiHuO00025QrE$V" GlobalId="2N8xi0qWiHuO00025QrE$V" Name="RecirculatedAir" Description="Loads from recirculated air." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="RecirculatedAirHistory_060HG0qWmHuO00025QrE$V" GlobalId="060HG0qWmHuO00025QrE$V" Name="RecirculatedAirHistory" Description="Loads from recirculated air." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="Reference_00pQO0qSSHuO00025QrE$V" GlobalId="00pQO0qSSHuO00025QrE$V" Name="Reference" Description="Reference ID for this specified type in this project (e.g. type &apos;A-1&apos;), Also referred to as &quot;construction type&quot;. It should be provided as an alternative to the name of the &quot;object type&quot;, if the software does not support object types and no classification reference to a recognized classification system used.

&gt; IFC4.3.0.0 DEPRECATION&amp;nbsp;  The Reference property is deprecated and shall no longer be used, use attribute Name on the relating type instead." TemplateType="p_singlevalue" PrimaryMeasureType="IfcIdentifier" />
				<IfcSimplePropertyTemplate id="Reference_02_Yc0qVGHuO00025QrE$V" GlobalId="02_Yc0qVGHuO00025QrE$V" Name="Reference" Description="Reference ID for this specified type in this project (e.g. type &apos;A-1&apos;), Also referred to as &quot;construction type&quot;. It should be provided as an alternative to the name of the &quot;object type&quot;, if the software does not support object types and no classification reference to a recognized classification system used.

&gt; IFC4.3.0.0 DEPRECATION&amp;nbsp;  The Reference property is deprecated and shall no longer be used, use attribute Name on the relating type instead.

E.g.  &apos;WWS/VS1/400/001&apos;, which indicates the occurrence belongs to system WWS, subsystems VSI/400, and has the component number 001." TemplateType="p_singlevalue" PrimaryMeasureType="IfcIdentifier" />
				<IfcSimplePropertyTemplate id="Reference_0hY220qW0HuO00025QrE$V" GlobalId="0hY220qW0HuO00025QrE$V" Name="Reference" Description="A descriptive label for the general reinforcement type." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="Reference_1Eij00qW0HuO00025QrE$V" GlobalId="1Eij00qW0HuO00025QrE$V" Name="Reference" Description="A descriptive label for the general reinforcement type." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="Reference_1qBEC0qTeHuO00025QrE$V" GlobalId="1qBEC0qTeHuO00025QrE$V" Name="Reference" Description="Reference ID for this specified type in this project (e.g. type &apos;A-1&apos;), Also referred to as &quot;construction type&quot;. It should be provided as an alternative to the name of the &quot;object type&quot;, if the software does not support object types and no classification reference to a recognized classification system used.

&gt; IFC4.3.0.0 DEPRECATION&amp;nbsp;  The Reference property is deprecated and shall no longer be used, use attribute Name on the relating type instead.

E.g. &apos;WWS/VS1&apos;, which indicates the system to be WWS, subsystems VSI/400." TemplateType="p_singlevalue" PrimaryMeasureType="IfcIdentifier" />
				<IfcSimplePropertyTemplate id="Reference_2aqqE0qVyHuO00025QrE$V" GlobalId="2aqqE0qVyHuO00025QrE$V" Name="Reference" Description="A descriptive label for the general reinforcement type." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="Reference_31l4Q0qW0HuO00025QrE$V" GlobalId="31l4Q0qW0HuO00025QrE$V" Name="Reference" Description="A descriptive label for the general reinforcement type." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="Reference_33frgWW4D3euBRuniN2rSn" GlobalId="33frgWW4D3euBRuniN2rSn" Name="Reference" Description="Reference ID for this specified type in this project (e.g. type &apos;A-1&apos;), Also referred to as &quot;construction type&quot;. It should be provided as an alternative to the name of the &quot;object type&quot;, if the software does not support object types." TemplateType="p_singlevalue" PrimaryMeasureType="IfcIdentifier" />
				<IfcSimplePropertyTemplate id="Reference_3BaNe0qVyHuO00025QrE$V" GlobalId="3BaNe0qVyHuO00025QrE$V" Name="Reference" Description="A descriptive label for the general reinforcement type." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="Reference_3fPzg0qX4HuO00025QrE$V" GlobalId="3fPzg0qX4HuO00025QrE$V" Name="Reference" Description="Reference ID for this specified type in this project (e.g. type &apos;A-1&apos;). Used to store the non-classification driven internal construction type." TemplateType="p_singlevalue" PrimaryMeasureType="IfcIdentifier" />
				<IfcSimplePropertyTemplate id="Reference_3iycO0qVyHuO00025QrE$V" GlobalId="3iycO0qVyHuO00025QrE$V" Name="Reference" Description="A descriptive label for the general reinforcement type." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ReferenceAirRelativeHumidity_1wG8Xp53PDOPLBMvLK0g1J" GlobalId="1wG8Xp53PDOPLBMvLK0g1J" Name="ReferenceAirRelativeHumidity" Description="Measurement of the ratio of water vapor in the air." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="ReferenceDepth_18i26IeYfElf48a3m5DXxE" GlobalId="18i26IeYfElf48a3m5DXxE" Name="ReferenceDepth" Description="Depth in bending for which the mechanical properties are valid; provided as a means to check the integrity of material assignment." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ReferenceDepth_21e1MA21r7PPjSW27cmYYl" GlobalId="21e1MA21r7PPjSW27cmYYl" Name="ReferenceDepth" Description="Depth in bending for which the mechanical properties are valid; provided as a means to check the integrity of material assignment." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ReferenceDepth_2IRbhBomnFhx9eIoVOIJHC" GlobalId="2IRbhBomnFhx9eIoVOIJHC" Name="ReferenceDepth" Description="Depth in bending for which the mechanical properties are valid; provided as a means to check the integrity of material assignment." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ReferenceDepth_2kL9bUrL56KxgsvGPmVNem" GlobalId="2kL9bUrL56KxgsvGPmVNem" Name="ReferenceDepth" Description="Depth in bending for which the mechanical properties are valid; provided as a means to check the integrity of material assignment." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ReferenceDepth_3AoKH7X0jEjxeJz28q4H$C" GlobalId="3AoKH7X0jEjxeJz28q4H$C" Name="ReferenceDepth" Description="Depth in bending for which the mechanical properties are valid; provided as a means to check the integrity of material assignment." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ReferenceDepth_3tD22xOOH0sxuHHjdxP6_W" GlobalId="3tD22xOOH0sxuHHjdxP6_W" Name="ReferenceDepth" Description="Depth in bending for which the mechanical properties are valid; provided as a means to check the integrity of material assignment." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ReferenceDistanceRopeToPulley_3CEvujvXv4h8b1bdTGctiY" GlobalId="3CEvujvXv4h8b1bdTGctiY" Name="ReferenceDistanceRopeToPulley" Description="The reference design criteria for distance from the end of the rope to the fixed pulley.It defines the nominal distance in relation to temperature." TemplateType="p_tablevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" SecondaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ReferenceDistanceTensionerToGround_3xKupe5RT6XRnMcxYkd5Qt" GlobalId="3xKupe5RT6XRnMcxYkd5Qt" Name="ReferenceDistanceTensionerToGround" Description="The reference design criteria distance from the last tensioner to the ground or the base surface (B value). It defines the nominal distance in relation to temperature." TemplateType="p_tablevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" SecondaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ReferenceEnvironmentTemperature_2vgOshA4D0$ems5HSBwemr" GlobalId="2vgOshA4D0$ems5HSBwemr" Name="ReferenceEnvironmentTemperature" Description="Ideal temperature range." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="RefreshRate_2tUrU0qS8HuO00025QrE$V" GlobalId="2tUrU0qS8HuO00025QrE$V" Name="RefreshRate" Description="Indicates the display refresh frequency." TemplateType="p_singlevalue" PrimaryMeasureType="IfcFrequencyMeasure" />
				<IfcSimplePropertyTemplate id="RefrigerantClass_0sT8u0qSiHuO00025QrE$V" GlobalId="0sT8u0qSiHuO00025QrE$V" Name="RefrigerantClass" Description="Refrigerant class used by the object.
CFC: Chlorofluorocarbons.
HCFC: Hydrochlorofluorocarbons.
HFC: Hydrofluorocarbons." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" id="i2706" Name="PEnum_RefrigerantClass">
						<EnumerationValues>
							<IfcLabel-wrapper>CFC</IfcLabel-wrapper>
							<IfcLabel-wrapper>HCFC</IfcLabel-wrapper>
							<IfcLabel-wrapper>HFC</IfcLabel-wrapper>
							<IfcLabel-wrapper>HYDROCARBONS</IfcLabel-wrapper>
							<IfcLabel-wrapper>AMMONIA</IfcLabel-wrapper>
							<IfcLabel-wrapper>CO2</IfcLabel-wrapper>
							<IfcLabel-wrapper>H2O</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="RefrigerantClass_0vUtY0qUCHuO00025QrE$V" GlobalId="0vUtY0qUCHuO00025QrE$V" Name="RefrigerantClass" Description="Refrigerant class used by the compressor.
CFC: Chlorofluorocarbons.
HCFC: Hydrochlorofluorocarbons.
HFC: Hydrofluorocarbons." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i2706" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="RefrigerantFoulingResistance_1hpQk0qSmHuO00025QrE$V" GlobalId="1hpQk0qSmHuO00025QrE$V" Name="RefrigerantFoulingResistance" Description="Fouling resistance on the refrigerant side." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcThermalResistanceMeasure" />
				<IfcSimplePropertyTemplate id="RefrigerantFoulingResistance_3Ox3k0qU8HuO00025QrE$V" GlobalId="3Ox3k0qU8HuO00025QrE$V" Name="RefrigerantFoulingResistance" Description="Fouling resistance on the refrigerant side." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcThermalResistanceMeasure" />
				<IfcSimplePropertyTemplate id="RegeneratedSoundCurve_1zPO80qT4HuO00025QrE$V" GlobalId="1zPO80qT4HuO00025QrE$V" Name="RegeneratedSoundCurve" Description="Regenerated sound versus air flow rate." TemplateType="p_tablevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" SecondaryMeasureType="IfcSoundPressureMeasure" />
				<IfcSimplePropertyTemplate id="Region_0Ja2l6PVP6xx9LVICEzJya" GlobalId="0Ja2l6PVP6xx9LVICEzJya" Name="Region" Description="The name of a region.

&gt; EXAMPLE&amp;nbsp; The counties of the United Kingdom and the states of North America are examples of regions." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ReheatType_2rhvK0qRuHuO00025QrE$V" GlobalId="2rhvK0qRuHuO00025QrE$V" Name="ReheatType" Description="Terminal box reheat type." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_AirTerminalBoxReheatType">
						<EnumerationValues>
							<IfcLabel-wrapper>ELECTRICALREHEAT</IfcLabel-wrapper>
							<IfcLabel-wrapper>WATERCOILREHEAT</IfcLabel-wrapper>
							<IfcLabel-wrapper>STEAMCOILREHEAT</IfcLabel-wrapper>
							<IfcLabel-wrapper>GASREHEAT</IfcLabel-wrapper>
							<IfcLabel-wrapper>NONE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Reinforcement_2syBe0qTuHuO00025QrE$V" GlobalId="2syBe0qTuHuO00025QrE$V" Name="Reinforcement" Description="The type of reinforcement, if any, used for the duct segment." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ReinforcementAreaRatio_03QJXaBBz9ugaDD64qh7Hr" GlobalId="03QJXaBBz9ugaDD64qh7Hr" Name="ReinforcementAreaRatio" Description="The required ratio of the effective area of the reinforcement to the effective area of the concrete At any section of a reinforced concrete structural element." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAreaDensityMeasure" />
				<IfcSimplePropertyTemplate id="ReinforcementBarType_3rIg40qVyHuO00025QrE$V" GlobalId="3rIg40qVyHuO00025QrE$V" Name="ReinforcementBarType" Description="Defines the type of the reinforcement bar." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ReinforcementBarType">
						<EnumerationValues>
							<IfcLabel-wrapper>RING</IfcLabel-wrapper>
							<IfcLabel-wrapper>SPIRAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>USERDEFINED</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTDEFINED</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ReinforcementSpacing_2yvfi0qTuHuO00025QrE$V" GlobalId="2yvfi0qTuHuO00025QrE$V" Name="ReinforcementSpacing" Description="The spacing between reinforcing elements." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ReinforcementStrengthClass_2uZA8bB4j05BpoYRkzMMEO" GlobalId="2uZA8bB4j05BpoYRkzMMEO" Name="ReinforcementStrengthClass" Description="Classification of the reinforcement strength in accordance with the concrete design code which is applied in the project. The reinforcing strength class often combines strength and ductility." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ReinforcementType_2$OfGxKXj3x8NK_1AVp3LA" GlobalId="2$OfGxKXj3x8NK_1AVp3LA" Name="ReinforcementType" Description="The type of reinforcement in the concrete element. May be used whenever reinforcement has not been explicitly modelled." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ReinforcementType">
						<EnumerationValues>
							<IfcLabel-wrapper>BAR</IfcLabel-wrapper>
							<IfcLabel-wrapper>REINFORCEMENTCAGE</IfcLabel-wrapper>
							<IfcLabel-wrapper>MESH</IfcLabel-wrapper>
							<IfcLabel-wrapper>FIBRE</IfcLabel-wrapper>
							<IfcLabel-wrapper>USERDEFINED</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ReinforcementVolumeRatio_2XmEU5oRn1XutRnd$G$pqc" GlobalId="2XmEU5oRn1XutRnd$G$pqc" Name="ReinforcementVolumeRatio" Description="The required ratio of the effective mass of the reinforcement to the effective volume of the concrete of a reinforced concrete structural element." TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassDensityMeasure" />
				<IfcSimplePropertyTemplate id="RelativeDensity_3SB3FKZuL3KRYmDmfBsQvb" GlobalId="3SB3FKZuL3KRYmDmfBsQvb" Name="RelativeDensity" Description="Relative density or density index is the ratio of the difference between the void ratios of a cohesionless soil in its loosest state and existing natural state to the difference between its void ratio in the loosest and densest states. (emax - e) /(emax-emin)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="RelativeHumidity_36qiC0qWiHuO00025QrE$V" GlobalId="36qiC0qWiHuO00025QrE$V" Name="RelativeHumidity" Description="Loads from the relative humidity." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="RelativeHumidityHistory_0IXMo0qWmHuO00025QrE$V" GlobalId="0IXMo0qWmHuO00025QrE$V" Name="RelativeHumidityHistory" Description="Loads from the relative humidity." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="Relaxations_3rGQM0qUqHuO00025QrE$V" GlobalId="3rGQM0qUqHuO00025QrE$V" Name="Relaxations" Description="Measures of decrease in stress over long time intervals resulting from plastic flow. Different relaxation values for different initial stress levels for a material may be given. It describes the time dependent relative relaxation value for a given initial stress level at constant strain.
Relating values are the &quot;RelaxationValue&quot;. Related values are the &quot;InitialStress&quot;" TemplateType="p_tablevalue" PrimaryMeasureType="IfcNormalisedRatioMeasure" SecondaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="ReleaseCurrent_1FbJC0qViHuO00025QrE$V" GlobalId="1FbJC0qViHuO00025QrE$V" Name="ReleaseCurrent" Description="The release current in [x In] for the initial tripping of the S-function." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="ReleaseCurrent_1N20o0qVeHuO00025QrE$V" GlobalId="1N20o0qVeHuO00025QrE$V" Name="ReleaseCurrent" Description="The release current in [x In] for the initial tripping of the S-function." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="ReleaseCurrent_2yM$s0qVeHuO00025QrE$V" GlobalId="2yM$s0qVeHuO00025QrE$V" Name="ReleaseCurrent" Description="The release current in [x In] for the initial tripping of the S-function." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="ReleaseCurrentI2tEnd_2Nj5M0qViHuO00025QrE$V" GlobalId="2Nj5M0qViHuO00025QrE$V" Name="ReleaseCurrentI2tEnd" Description="The release current in [x In].

For the end point of the I2t tripping curve of the S-function, if any. The value of ReleaseCurrentI2tEnd shall be larger than ReleaseCurrentI2tStart." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="ReleaseCurrentI2tEnd_2SB3w0qVeHuO00025QrE$V" GlobalId="2SB3w0qVeHuO00025QrE$V" Name="ReleaseCurrentI2tEnd" Description="The release current in [x In].

For the end point of the I2t tripping curve of the G-function, if any. The value of ReleaseCurrentI2tEnd shall be larger than ReleaseCurrentI2tStart." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="ReleaseCurrentI2tStart_2COIe0qViHuO00025QrE$V" GlobalId="2COIe0qViHuO00025QrE$V" Name="ReleaseCurrentI2tStart" Description="The release current in [x In].

For the start point of the I2t tripping curve of the S-function, if any." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="ReleaseCurrentI2tStart_2HSQc0qVeHuO00025QrE$V" GlobalId="2HSQc0qVeHuO00025QrE$V" Name="ReleaseCurrentI2tStart" Description="The release current in [x In].

For the start point of the I2t tripping curve of the G-function, if any." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="ReleaseDate_18Baepiu9DMu1YZ7vyV2Zi" GlobalId="18Baepiu9DMu1YZ7vyV2Zi" Name="ReleaseDate" Description="Date of release of the model." TemplateType="p_singlevalue" PrimaryMeasureType="IfcDate" />
				<IfcSimplePropertyTemplate id="ReleaseStrength_39TUu0qVGHuO00025QrE$V" GlobalId="39TUu0qVGHuO00025QrE$V" Name="ReleaseStrength" Description="The minimum required compressive strength of the concrete when the tendon stress is released. This property applies to prestressed concrete elements only." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="ReleaseTime_1Kyds0qViHuO00025QrE$V" GlobalId="1Kyds0qViHuO00025QrE$V" Name="ReleaseTime" Description="The release time in [s] for the initial tripping of the relevant part. This time indicates that for current lower than the indicated release current, the tripping time will be longer than the indicated release time. The value is given as a mean value." TemplateType="p_singlevalue" PrimaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="ReleaseTime_1RpC20qVeHuO00025QrE$V" GlobalId="1RpC20qVeHuO00025QrE$V" Name="ReleaseTime" Description="The release time in [s] for the initial tripping of the relevant part. This time indicates that for current lower than the indicated release current, the tripping time will be longer than the indicated release time. The value is given as a mean value." TemplateType="p_singlevalue" PrimaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="ReleaseTime_32KTw0qVeHuO00025QrE$V" GlobalId="32KTw0qVeHuO00025QrE$V" Name="ReleaseTime" Description="The release time in [s] for the initial tripping of the relevant part. This time indicates that for current lower than the indicated release current, the tripping time will be longer than the indicated release time. The value is given as a mean value." TemplateType="p_singlevalue" PrimaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="ReleaseTimeI2tEnd_2UGiq0qViHuO00025QrE$V" GlobalId="2UGiq0qViHuO00025QrE$V" Name="ReleaseTimeI2tEnd" Description="The release time in [s].

For the end point of the I2 tripping curve of the S-function, if any. The value of ReleaseTimeI2tEnd shall be lower than ReleaseTimeI2tStart." TemplateType="p_singlevalue" PrimaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="ReleaseTimeI2tEnd_2Y8X_0qVeHuO00025QrE$V" GlobalId="2Y8X_0qVeHuO00025QrE$V" Name="ReleaseTimeI2tEnd" Description="The release time in [s].

For the end point of the I2 tripping curve of the G-function, if any. The value of ReleaseTimeI2tEnd shall be lower than ReleaseTimeI2tStart." TemplateType="p_singlevalue" PrimaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="ReleaseTimeI2tStart_2Ixw60qViHuO00025QrE$V" GlobalId="2Ixw60qViHuO00025QrE$V" Name="ReleaseTimeI2tStart" Description="The release time in [s].

For the start point of the I2t tripping curve of the S-function, if any" TemplateType="p_singlevalue" PrimaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="ReleaseTimeI2tStart_2MplG0qVeHuO00025QrE$V" GlobalId="2MplG0qVeHuO00025QrE$V" Name="ReleaseTimeI2tStart" Description="The release time in [s].

For the start point of the I2t tripping curve of the G-function, if any." TemplateType="p_singlevalue" PrimaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="ReleaseVoltage_0ALfiH0FPD8wl_QfJHs5JI" GlobalId="0ALfiH0FPD8wl_QfJHs5JI" Name="ReleaseVoltage" Description="The maximum voltage to guarantee the drop of the relay node." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricVoltageMeasure" />
				<IfcSimplePropertyTemplate id="ReliefPressure_1irli0qXKHuO00025QrE$V" GlobalId="1irli0qXKHuO00025QrE$V" Name="ReliefPressure" Description="The pressure at which the spring or weight in the valve is set to discharge fluid." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="ReliefValveSetting_1VQq80qX0HuO00025QrE$V" GlobalId="1VQq80qX0HuO00025QrE$V" Name="ReliefValveSetting" Description="Pressure at which the relief valve activates." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="ReliefValveSetting_2mUpO0qX0HuO00025QrE$V" GlobalId="2mUpO0qX0HuO00025QrE$V" Name="ReliefValveSetting" Description="Pressure at which the relief valve activates." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="RemainingCost_3xSre0qSmHuO00025QrE$V" GlobalId="3xSre0qSmHuO00025QrE$V" Name="RemainingCost" Description="The remaining cost on behalf of the resource allocation." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcMonetaryMeasure" />
				<IfcSimplePropertyTemplate id="RemainingWorkProgression_3pixM0qSmHuO00025QrE$V" GlobalId="3pixM0qSmHuO00025QrE$V" Name="RemainingWorkProgression" Description="The remaining work on behalf of the resource allocation." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcDuration" />
				<IfcSimplePropertyTemplate id="RemoteReading_0gIlc0qUWHuO00025QrE$V" GlobalId="0gIlc0qUWHuO00025QrE$V" Name="RemoteReading" Description="Indicates whether the meter has a connection for remote reading through connection of a communication device (set TRUE) or not (set FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="RenewableEnergyConsumption_0bWqS0qU8HuO00025QrE$V" GlobalId="0bWqS0qU8HuO00025QrE$V" Name="RenewableEnergyConsumption" Description="Quantity of renewable energy used as defined in ISO21930:2007" TemplateType="p_singlevalue" PrimaryMeasureType="IfcEnergyMeasure" />
				<IfcSimplePropertyTemplate id="RenewableEnergyConsumptionPerUnit_3F5WY0qU4HuO00025QrE$V" GlobalId="3F5WY0qU4HuO00025QrE$V" Name="RenewableEnergyConsumptionPerUnit" Description="Quantity of renewable energy used as defined in ISO21930:2007" TemplateType="p_singlevalue" PrimaryMeasureType="IfcEnergyMeasure" />
				<IfcSimplePropertyTemplate id="RentalRatesInCategoryFuture_3$Jwu0qSKHuO00025QrE$V" GlobalId="3$Jwu0qSKHuO00025QrE$V" Name="RentalRatesInCategoryFuture" Description="Range of the cost rates for property expected to be available in the future in the required category." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcMonetaryMeasure" />
				<IfcSimplePropertyTemplate id="RentalRatesInCategoryNow_3bhcQ0qSKHuO00025QrE$V" GlobalId="3bhcQ0qSKHuO00025QrE$V" Name="RentalRatesInCategoryNow" Description="Range of the cost rates for property currently available in the required category." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcMonetaryMeasure" />
				<IfcSimplePropertyTemplate id="RepairContent_2uB5y1E3H1zuDscjqI6Rjw" GlobalId="2uB5y1E3H1zuDscjqI6Rjw" Name="RepairContent" Description="Content of repair, reason and nature can be given, e.g. display faults, communication failure, display exchange." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="RepairDate_1fKpvOEozEKQHboTTf4_f7" GlobalId="1fKpvOEozEKQHboTTf4_f7" Name="RepairDate" Description="Date on which the last repair is done on the asset." TemplateType="p_singlevalue" PrimaryMeasureType="IfcDate" />
				<IfcSimplePropertyTemplate id="ReplacementLevel_0zVRGQx$r18AMXYOzl_qyE" GlobalId="0zVRGQx$r18AMXYOzl_qyE" Name="ReplacementLevel" Description="Performance level at which replacement takes place" TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="RepresentativeAge_0IUFUUDNnBTfdUGKBAJimE" GlobalId="0IUFUUDNnBTfdUGKBAJimE" Name="RepresentativeAge" Description="A URI referring to a controlled concept specifying the most representative stratigraphic age interval for the GeologicUnit. This will be defined entirely at the discretion of the data provider and may be a single event selected from the geologic feature&apos;s geological history or a value summarising the all or part of the feature&apos;s history." TemplateType="p_singlevalue" PrimaryMeasureType="IfcIdentifier" />
				<IfcSimplePropertyTemplate id="RequestComments_3miCa0qRmHuO00025QrE$V" GlobalId="3miCa0qRmHuO00025QrE$V" Name="RequestComments" Description="Comments that may be made on the request." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="RequestSourceLabel_3WcEc0qRmHuO00025QrE$V" GlobalId="3WcEc0qRmHuO00025QrE$V" Name="RequestSourceLabel" Description="A specific name or label that further qualifies the identity of a request source. In the event of an email, this may be the email address." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="RequestSourceName_3gkkW0qRmHuO00025QrE$V" GlobalId="3gkkW0qRmHuO00025QrE$V" Name="RequestSourceName" Description="The person making the request, where known." TemplateType="p_referencevalue" PrimaryMeasureType="IfcPerson" />
				<IfcSimplePropertyTemplate id="RequiredClosureSpacing_0gtHi_RV90UARAfwx4UFx3" GlobalId="0gtHi_RV90UARAfwx4UFx3" Name="RequiredClosureSpacing" Description="Required length of the closure spacing." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="RequiredDisplayDistance_36D8aP$xH6CecE2OoCc7Dx" GlobalId="36D8aP$xH6CecE2OoCc7Dx" Name="RequiredDisplayDistance" Description="The required distance that has to be displayed. The value relates only to the signal type, not to the circumstances at a special position." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="RequiredHeadroom_04X1k0qWqHuO00025QrE$V" GlobalId="04X1k0qWqHuO00025QrE$V" Name="RequiredHeadroom" Description="Required headroom clearance for the passageway according to the applicable building code or additional requirements." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="RequiredHeadroom_15TJE0qVyHuO00025QrE$V" GlobalId="15TJE0qVyHuO00025QrE$V" Name="RequiredHeadroom" Description="Required headroom clearance for the passageway according to the applicable building code or additional requirements." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="RequiredSlope_1C0wi0qVyHuO00025QrE$V" GlobalId="1C0wi0qVyHuO00025QrE$V" Name="RequiredSlope" Description="Required sloping angle of the object - relative to horizontal (0.0 degrees).
Required maximum slope for the passageway according to the applicable building code or additional requirements." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="RequiresBannerSignal_2cBDBcV2H8HvKswkpaUxpJ" GlobalId="2cBDBcV2H8HvKswkpaUxpJ" Name="RequiresBannerSignal" Description="Indicates whether a banner repeater signal is required." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="RequiresOLEMesh_2lR_SlvAbENQL3ZSWl6HTj" GlobalId="2lR_SlvAbENQL3ZSWl6HTj" Name="RequiresOLEMesh" Description="Indicates whether an OLE mesh is required to protect the signal or maintainer." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="RequiresSafetyHandrail_1nZR15WS156fFW_vfybVP0" GlobalId="1nZR15WS156fFW_vfybVP0" Name="RequiresSafetyHandrail" Description="Indicates whether a safety handrail is required." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="ResidualCohesion_21T5RytGz4yvSfcQD$D7p2" GlobalId="21T5RytGz4yvSfcQD$D7p2" Name="ResidualCohesion" Description="Cohesion is a shear strength parameter of soils. Its definition is derived from the Mohr-Coulomb failure criterion and is used to describe the shear resistance of soils that is independent from the normal effective stress. The residual value correspond to the shear strength measured at large strain values during the test." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="ResidualFlowingPressure_1o7L40qUSHuO00025QrE$V" GlobalId="1o7L40qUSHuO00025QrE$V" Name="ResidualFlowingPressure" Description="The residual flowing pressure in the pipeline at which the discharge flow rate is determined." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="ResidualFrictionAngle_3VU660bRHEbQc1t926BAZb" GlobalId="3VU660bRHEbQc1t926BAZb" Name="ResidualFrictionAngle" Description="Soil effective stress friction angle is a shear strength parameter of soils. Its definition is derived from the Mohr-Coulomb failure criterion and it is used to describe the friction shear resistance of soils with the normal effective stress. The residual value correspond to the shear strength measured at large strain values during the test." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="ResidualStrengthStructualClass_2M4sn4MkvDoPCXacy2_xw0" GlobalId="2M4sn4MkvDoPCXacy2_xw0" Name="ResidualStrengthStructualClass" Description="Residual Strength Ratio to fib Model Code 2010, fibre reinforced concrete." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ResidualStrengthStructuralClass">
						<EnumerationValues>
							<IfcLabel-wrapper>A</IfcLabel-wrapper>
							<IfcLabel-wrapper>B</IfcLabel-wrapper>
							<IfcLabel-wrapper>C</IfcLabel-wrapper>
							<IfcLabel-wrapper>D</IfcLabel-wrapper>
							<IfcLabel-wrapper>E</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ResidualTensileStrengthfLk_3rh_yPnNbC7RdUAuRCMnHg" GlobalId="3rh_yPnNbC7RdUAuRCMnHg" Name="ResidualTensileStrengthfLk" Description="fLk to fib Model Code 2010, fibre reinforced concrete." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="ResidualTensileStrengthfR1k_2tdtfQJTvDgxR2fqlv2GfM" GlobalId="2tdtfQJTvDgxR2fqlv2GfM" Name="ResidualTensileStrengthfR1k" Description="fR1k to fib Model Code 2010, fibre reinforced concrete." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="ResidualTensileStrengthfR3k_3eVnIQ8sXBYxb3JbnYq3du" GlobalId="3eVnIQ8sXBYxb3JbnYq3du" Name="ResidualTensileStrengthfR3k" Description="fR3k to fib Model Code 2010, fibre reinforced concrete." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="ResistanceToGround_2cjcL0mEjDXPYwqZazv4A9" GlobalId="2cjcL0mEjDXPYwqZazv4A9" Name="ResistanceToGround" Description="The resistance through earthing conductor to the ground. Real part of the impedance to earth [SOURCE IEC: 195-01-18]" TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricResistanceMeasure" />
				<IfcSimplePropertyTemplate id="Resistivity_0CD1$azajCjeK721qDipOz" GlobalId="0CD1$azajCjeK721qDipOz" Name="Resistivity" Description="Electrical resistivity (Ohm-m)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricalResistivityMeasure" />
				<IfcSimplePropertyTemplate id="ResourceDepletion_0mFTm0qU8HuO00025QrE$V" GlobalId="0mFTm0qU8HuO00025QrE$V" Name="ResourceDepletion" Description="Quantity of resources used calculated in equivalent antimony." TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassMeasure" />
				<IfcSimplePropertyTemplate id="ResourceDepletionPerUnit_3R0Sg0qU4HuO00025QrE$V" GlobalId="3R0Sg0qU4HuO00025QrE$V" Name="ResourceDepletionPerUnit" Description="Quantity of resources used calculated in equivalent antimony" TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassMeasure" />
				<IfcSimplePropertyTemplate id="Response_0zgPK0qUSHuO00025QrE$V" GlobalId="0zgPK0qUSHuO00025QrE$V" Name="Response" Description="Identifies the predefined methods of sprinkler response from which that required may be set." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_SprinklerResponse">
						<EnumerationValues>
							<IfcLabel-wrapper>QUICK</IfcLabel-wrapper>
							<IfcLabel-wrapper>STANDARD</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Restrictions_2QONk0qVWHuO00025QrE$V" GlobalId="2QONk0qVWHuO00025QrE$V" Name="Restrictions" Description="Restrictions that may be placed by a competent authority." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="ReticularArchType_08Yo2Ip_fAMRuKPkd8Ied2" GlobalId="08Yo2Ip_fAMRuKPkd8Ied2" Name="ReticularArchType" Description="Specifies the type when the arch is made of interlaced profiles." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ReturnAirFractionRange_3nulM0qRuHuO00025QrE$V" GlobalId="3nulM0qRuHuO00025QrE$V" Name="ReturnAirFractionRange" Description="Allowable return air fraction range as a fraction of discharge airflow." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="ReturnWaterTemperatureCooling_1PxGW0qSuHuO00025QrE$V" GlobalId="1PxGW0qSuHuO00025QrE$V" Name="ReturnWaterTemperatureCooling" Description="Return water temperature in cooling mode." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="ReturnWaterTemperatureHeating_1WUt_0qSuHuO00025QrE$V" GlobalId="1WUt_0qSuHuO00025QrE$V" Name="ReturnWaterTemperatureHeating" Description="Return water temperature in heating mode." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="RightFlangeWidth_1tWPW0qVKHuO00025QrE$V" GlobalId="1tWPW0qVKHuO00025QrE$V" Name="RightFlangeWidth" Description="Right flange width of the profile." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="RingType_19mOtbL$f8jRVRPXORtt$x" GlobalId="19mOtbL$f8jRVRPXORtt$x" Name="RingType" Description="Type of ring." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_RingType">
						<EnumerationValues>
							<IfcLabel-wrapper>UNIVERSAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>CONICAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>PARALLEL</IfcLabel-wrapper>
							<IfcLabel-wrapper>PARALLEL_WITH_CORRECTIVE_RINGS</IfcLabel-wrapper>
							<IfcLabel-wrapper>SWISS_TÜBBING</IfcLabel-wrapper>
							<IfcLabel-wrapper>INVERT_SEGMENT_WITH_SHOTCRETE</IfcLabel-wrapper>
							<IfcLabel-wrapper>HEXAGONAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>USERDEFINED</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="RiserHeight_1QyLe0qWqHuO00025QrE$V" GlobalId="1QyLe0qWqHuO00025QrE$V" Name="RiserHeight" Description="Vertical distance from tread to tread.
The riser height is supposed to be equal for all steps of a stair or stair flight." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="RiserHeight_3oedY0qWmHuO00025QrE$V" GlobalId="3oedY0qWmHuO00025QrE$V" Name="RiserHeight" Description="Vertical distance from tread to tread.
The riser height is supposed to be equal for all steps of a stair or stair flight." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="RiskAssessmentMethodology_09ClN62Hr79h3URe8omgR9" GlobalId="09ClN62Hr79h3URe8omgR9" Name="RiskAssessmentMethodology" Description="An indication or link to the chosen risk assessment methodology, for example PAS1192-6 or a chosen ISO13100 annex." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="RiskName_0gOQsqV_bA4gUGjAMYalbC" GlobalId="0gOQsqV_bA4gUGjAMYalbC" Name="RiskName" Description="A locally unique identifier for the risk entry that can be used to track the development and mitigation of the risk throughout the project life cycle" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="RiskType_1JPHxf_1r6Ggkz9sLX8cSQ" GlobalId="1JPHxf_1r6Ggkz9sLX8cSQ" Name="RiskType" Description="Identifies the predefined types of risk from which the type required may be set." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_RiskType">
						<EnumerationValues>
							<IfcLabel-wrapper>BUSINESS</IfcLabel-wrapper>
							<IfcLabel-wrapper>HAZARD</IfcLabel-wrapper>
							<IfcLabel-wrapper>HEALTHANDSAFETY</IfcLabel-wrapper>
							<IfcLabel-wrapper>INSURANCE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
							<IfcLabel-wrapper>HEALTHISSUE</IfcLabel-wrapper>
							<IfcLabel-wrapper>MATERIALEFFECTS</IfcLabel-wrapper>
							<IfcLabel-wrapper>ASBESTOSEFFECTS</IfcLabel-wrapper>
							<IfcLabel-wrapper>LEADEFFECTS</IfcLabel-wrapper>
							<IfcLabel-wrapper>HAZARDOUSDUST</IfcLabel-wrapper>
							<IfcLabel-wrapper>WOODDUST</IfcLabel-wrapper>
							<IfcLabel-wrapper>SILICADUST</IfcLabel-wrapper>
							<IfcLabel-wrapper>CHEMICALEFFECTS</IfcLabel-wrapper>
							<IfcLabel-wrapper>MECHANICALEFFECTS</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOISE_EFFECTS</IfcLabel-wrapper>
							<IfcLabel-wrapper>TOOLUSAGE</IfcLabel-wrapper>
							<IfcLabel-wrapper>VIBRATION</IfcLabel-wrapper>
							<IfcLabel-wrapper>WELFAREISSUE</IfcLabel-wrapper>
							<IfcLabel-wrapper>SAFETYISSUE</IfcLabel-wrapper>
							<IfcLabel-wrapper>FALL</IfcLabel-wrapper>
							<IfcLabel-wrapper>FALL_LADDER</IfcLabel-wrapper>
							<IfcLabel-wrapper>FALLEDGE</IfcLabel-wrapper>
							<IfcLabel-wrapper>FALLSCAFFOLD</IfcLabel-wrapper>
							<IfcLabel-wrapper>FALLFRAGILEMATERIAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>SLIPTRIP</IfcLabel-wrapper>
							<IfcLabel-wrapper>TRAPPED</IfcLabel-wrapper>
							<IfcLabel-wrapper>CONFINEMENT</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNINTENDEDCOLLAPSE</IfcLabel-wrapper>
							<IfcLabel-wrapper>CRUSHING</IfcLabel-wrapper>
							<IfcLabel-wrapper>ASPHIXIATION</IfcLabel-wrapper>
							<IfcLabel-wrapper>DROWNINGANDFLOODING</IfcLabel-wrapper>
							<IfcLabel-wrapper>EVENT</IfcLabel-wrapper>
							<IfcLabel-wrapper>ELECTRICSHOCK</IfcLabel-wrapper>
							<IfcLabel-wrapper>FIRE_EXPLOSION</IfcLabel-wrapper>
							<IfcLabel-wrapper>MACHINERYGUARDING</IfcLabel-wrapper>
							<IfcLabel-wrapper>HANDLING</IfcLabel-wrapper>
							<IfcLabel-wrapper>MATERIALSHANDLING</IfcLabel-wrapper>
							<IfcLabel-wrapper>MECHANICAL_LIFTING</IfcLabel-wrapper>
							<IfcLabel-wrapper>MOBILE_ELEVATEDWORKPLATFORM</IfcLabel-wrapper>
							<IfcLabel-wrapper>WORKINGOVERHEAD</IfcLabel-wrapper>
							<IfcLabel-wrapper>STRUCK</IfcLabel-wrapper>
							<IfcLabel-wrapper>STRUCKFALLINFOBJECT</IfcLabel-wrapper>
							<IfcLabel-wrapper>STRUCKVEHICLE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OVERTURINGPLANT</IfcLabel-wrapper>
							<IfcLabel-wrapper>PUBLICPROTECTIONISSUES</IfcLabel-wrapper>
							<IfcLabel-wrapper>ENVIRONMENTALISSUES</IfcLabel-wrapper>
							<IfcLabel-wrapper>BUSINESSISSUES</IfcLabel-wrapper>
							<IfcLabel-wrapper>COMMERICALISSUES</IfcLabel-wrapper>
							<IfcLabel-wrapper>INSURANCE_ISSUES</IfcLabel-wrapper>
							<IfcLabel-wrapper>OPERATIONALISSUES</IfcLabel-wrapper>
							<IfcLabel-wrapper>SOCIALISSUES</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHERISSUES</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="RMR_0P4g7RHODAnPtwhbwtKXgn" GlobalId="0P4g7RHODAnPtwhbwtKXgn" Name="RMR" Description="The rock mass rating (RMR) is a geomechanical classification system for rocks.
&gt;NOTE Definition from ASTM (1988). Standard Guide for using the Rock Mass Rating (RMR) System (Geomechanics Classification) in Engineering Practices. American Society for Testing and Materials, Book of Standards D5878-08, v.04.09, Philadelphia, PA." TemplateType="p_singlevalue" PrimaryMeasureType="IfcInteger" />
				<IfcSimplePropertyTemplate id="RMR_1FyiAF9_X6qxr7V$dZ3Yiv" GlobalId="1FyiAF9_X6qxr7V$dZ3Yiv" Name="RMR" Description="The rock mass rating (RMR) is a geomechanical classification system for rocks, developed by Z. T. Bieniawski." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveInteger" />
				<IfcSimplePropertyTemplate id="RMSWithstandVoltage_29RnvrWq5DXAWWDKKhvsNo" GlobalId="29RnvrWq5DXAWWDKKhvsNo" Name="RMSWithstandVoltage" Description="Rms value of sinusoidal power frequency voltage that the insulation of the given equipment can withstand during tests made under specified conditions and for a specified duration. (IEV ref 614-03-22）" TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricVoltageMeasure" />
				<IfcSimplePropertyTemplate id="RoadDesignClass_22loa_egPD6AlK4tbbeF4d" GlobalId="22loa_egPD6AlK4tbbeF4d" Name="RoadDesignClass" Description="A road design class designator with content according to local standards." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="RoadVisibleDistanceLeft_1Hsfk0qS4HuO00025QrE$V" GlobalId="1Hsfk0qS4HuO00025QrE$V" Name="RoadVisibleDistanceLeft" Description="Distance visible to the left of the access." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="RoadVisibleDistanceRight_1Nq7o0qS4HuO00025QrE$V" GlobalId="1Nq7o0qS4HuO00025QrE$V" Name="RoadVisibleDistanceRight" Description="Distance visible to the right of the access." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="RockMassRating_2qdGAN$0PBMO5OKXlwlUlX" GlobalId="2qdGAN$0PBMO5OKXlwlUlX" Name="RockMassRating" Description="The rock mass rating (RMR) is a geomechanical classification system for rocks, developed by Z. T. Bieniawski." TemplateType="p_singlevalue" PrimaryMeasureType="IfcInteger" />
				<IfcSimplePropertyTemplate id="RockQualityDesignation_2o32BT3ZX4bO$w85z$rZ25" GlobalId="2o32BT3ZX4bO$w85z$rZ25" Name="RockQualityDesignation" Description="Quotient of the cumulative length of drill cores with a length greater than 10 cm, by the total length of the drill core pass with a length greater than or equal to 1m." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="RockQualityDesignation_2OwiKpq$T2WBhXOg_6HYJQ" GlobalId="2OwiKpq$T2WBhXOg_6HYJQ" Name="RockQualityDesignation" Description="Length of solid core each pieces longer than 100 mm expressed as a ratio of the length of core run." TemplateType="p_singlevalue" PrimaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="RockVolume_0SPTVxj$v8yRPpgU52A4YI" GlobalId="0SPTVxj$v8yRPpgU52A4YI" Name="RockVolume" Description="Relative volume of rock stratum constituents." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumeMeasure" />
				<IfcSimplePropertyTemplate id="ROI_2LQFM4SPr2lPjRm$a3rQvD" GlobalId="2LQFM4SPr2lPjRm$a3rQvD" Name="ROI" Description="Return on Investment" TemplateType="p_singlevalue" PrimaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="Roll_0Zgei0qSGHuO00025QrE$V" GlobalId="0Zgei0qSGHuO00025QrE$V" Name="Roll" Description="Rotation against the longitudinal axis.

Relative to the global Z direction for all beams that are non-vertical in regard to the global coordinate system (Profile direction equals global Z is Roll = 0.)The shape information is provided in addition to the shape representation and the geometric parameters used within. In cases of inconsistency between the geometric parameters and the shape properties, provided in the attached property, the geometric parameters take precedence.  For geometry editing applications, like CAD: this value should be write-only. 

Note: new property in IFC4" TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="Roll_1fCNq0qV4HuO00025QrE$V" GlobalId="1fCNq0qV4HuO00025QrE$V" Name="Roll" Description="Rotation against the longitudinal axis.

Relative to the global Z direction for all members that are non-vertical in regard to the global coordinate system (Profile direction equals global Z is Roll = 0.)
The shape information is provided in addition to the shape representation and the geometric parameters used within. In cases of inconsistency between the geometric parameters and the shape properties, provided in the attached property, the geometric parameters take precedence.

&gt;NOTE&amp;nbsp; new property in IFC4." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="Roll_1nmeq0qSeHuO00025QrE$V" GlobalId="1nmeq0qSeHuO00025QrE$V" Name="Roll" Description="Rotation against the longitudinal axis.

Relative to the global  X direction for all columns that are vertical in regard to the global coordinate system (Profile direction equals global X is Roll = 0.). For all non-vertical columns the following applies:  Roll is relative to the global Z direction f(Profile direction of non-vertical columns that equals global Z is Roll = 0.)The shape information is provided in addition to the shape representation and the geometric parameters used within. In cases of inconsistency between the geometric parameters and the shape properties, provided in the attached property, the geometric parameters take precedence.  For geometry editing applications, like CAD: this value should be write-only.Note: new property in IFC4" TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="RotationAccommodated_3HTi12lhD0vuMfKNNsFx$D" GlobalId="3HTi12lhD0vuMfKNNsFx$D" Name="RotationAccommodated" Description="A list of exactly three boolean values representing an accommodated rotation (value TRUE or 1) or no rotation (value FALSE or 0) about the corresponding axis where the first value represents axis X, second value axis Y and third value axis Z." TemplateType="p_listvalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="RotationalSpeed_1XFhDz$Wr6ghIQ9AIkzOVX" GlobalId="1XFhDz$Wr6ghIQ9AIkzOVX" Name="RotationalSpeed" Description="Speed of rotation of nozzle." TemplateType="p_singlevalue" PrimaryMeasureType="IfcRotationalFrequencyMeasure" />
				<IfcSimplePropertyTemplate id="RotationSpeed_2mSZg0qVuHuO00025QrE$V" GlobalId="2mSZg0qVuHuO00025QrE$V" Name="RotationSpeed" Description="Pump rotational speed." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcRotationalFrequencyMeasure" />
				<IfcSimplePropertyTemplate id="Roughness_2Xt540qWSHuO00025QrE$V" GlobalId="2Xt540qWSHuO00025QrE$V" Name="Roughness" Description="A measure of the vertical deviations of the surface." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="RoundLength_2Px7GAEKr9oPOVi4hIhBDX" GlobalId="2Px7GAEKr9oPOVi4hIhBDX" Name="RoundLength" Description="Length of individual round or drive." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="RRUConnectionType_2llH13$EvAY8Lc9VG04k0Z" GlobalId="2llH13$EvAY8Lc9VG04k0Z" Name="RRUConnectionType" Description="Indicates the connection type between the remote radio unit and baseband unit." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" id="i2817" Name="PEnum_UnitConnectionType">
						<EnumerationValues>
							<IfcLabel-wrapper>CHAIN</IfcLabel-wrapper>
							<IfcLabel-wrapper>MIXED</IfcLabel-wrapper>
							<IfcLabel-wrapper>RING</IfcLabel-wrapper>
							<IfcLabel-wrapper>STAR</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="RUConnectionType_3QHGcFv6z8IQq_4_0gv5Jf" GlobalId="3QHGcFv6z8IQq_4_0gv5Jf" Name="RUConnectionType" Description="Indicate the connection type between the remote unit and the master unit." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i2817" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="RuntimeAtFullLoad_1Wa6XnYx56p8rACT$SifuH" GlobalId="1Wa6XnYx56p8rACT$SifuH" Name="RuntimeAtFullLoad" Description="Runtime at full load of the battery." TemplateType="p_singlevalue" PrimaryMeasureType="IfcDuration" />
				<IfcSimplePropertyTemplate id="SafetyDocument_0oiMmeRHTAL8wF_F2pVv8T" GlobalId="0oiMmeRHTAL8wF_F2pVv8T" Name="SafetyDocument" Description="Manufacturer&apos;s safety document" TemplateType="p_referencevalue" PrimaryMeasureType="IfcDocumentReference" />
				<IfcSimplePropertyTemplate id="SaltMistLevel_3rzK_24B55FhlIh99zlW26" GlobalId="3rzK_24B55FhlIh99zlW26" Name="SaltMistLevel" Description="Maximum level of salt mist that the equipment can operate effectively in. It is provided according to an international or national standard." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="SampleBoreholeDepthRange_16N06qRHf0NOknS38zpWxi" GlobalId="16N06qRHf0NOknS38zpWxi" Name="SampleBoreholeDepthRange" Description="Relative top and bottom depths of a borehole where a sample was retrieved." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcNonNegativeLengthMeasure" />
				<IfcSimplePropertyTemplate id="SampleProcedure_11BJJlK11Fr85RrFLwOBti" GlobalId="11BJJlK11Fr85RrFLwOBti" Name="SampleProcedure" Description="Description of steps performed by a Sampler in order to extract a Sample from its sampledFeature in the frame of a Sampling." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="SamplePurpose_2iAtC8BjvBEhsp1U8MpM6Y" GlobalId="2iAtC8BjvBEhsp1U8MpM6Y" Name="SamplePurpose" Description="Provides the reason why the sample was collected, planed methods for testingand analysis." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="SampleType_0WMz0ZD4vElw3tlESF7X88" GlobalId="0WMz0ZD4vElw3tlESF7X88" Name="SampleType" Description="Type of a sample with respect to sampling method and material, with e.g. enumerations as defined in AGS." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="SamplingFrequency_206umwul56iODHW70dgFt2" GlobalId="206umwul56iODHW70dgFt2" Name="SamplingFrequency" Description="Indicates the sampling frequency of the device." TemplateType="p_singlevalue" PrimaryMeasureType="IfcFrequencyMeasure" />
				<IfcSimplePropertyTemplate id="SamplingPointType_3snE6alTz82vidqo5JBy_l" GlobalId="3snE6alTz82vidqo5JBy_l" Name="SamplingPointType" Description="Specifies the location from where the material sample was obtained, e.g. outcrop point, tunnel chainage, any other local reference." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="SandVolume_20m14N5iL90PJuL8U083Zy" GlobalId="20m14N5iL90PJuL8U083Zy" Name="SandVolume" Description="Relative volume of sand (typically smaller than 2mm) stratum constituents." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumeMeasure" />
				<IfcSimplePropertyTemplate id="SaturationEfficiency_2dmpc0qUaHuO00025QrE$V" GlobalId="2dmpc0qUaHuO00025QrE$V" Name="SaturationEfficiency" Description="Saturation efficiency: Ratio of leaving air absolute humidity to the maximum absolute humidity." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="SaturationEfficiencyCurve_02zIm0qUeHuO00025QrE$V" GlobalId="02zIm0qUeHuO00025QrE$V" Name="SaturationEfficiencyCurve" Description="Saturation efficiency as a function of the air flow rate." TemplateType="p_tablevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" SecondaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="ScheduleCompletion_3_Rag0qSmHuO00025QrE$V" GlobalId="3_Rag0qSmHuO00025QrE$V" Name="ScheduleCompletion" Description="The scheduled completion percentage of the allocation." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="ScheduleCost_3shgO0qSmHuO00025QrE$V" GlobalId="3shgO0qSmHuO00025QrE$V" Name="ScheduleCost" Description="The budgeted cost on behalf of the resource allocation." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcMonetaryMeasure" />
				<IfcSimplePropertyTemplate id="ScheduledFrequency_2$eRe0qVSHuO00025QrE$V" GlobalId="2$eRe0qVSHuO00025QrE$V" Name="ScheduledFrequency" Description="The period of time between expected instantiations of a work order that may have been predefined." TemplateType="p_singlevalue" PrimaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="ScheduleWorkProgression_3kLci0qSmHuO00025QrE$V" GlobalId="3kLci0qSmHuO00025QrE$V" Name="ScheduleWorkProgression" Description="The scheduled work on behalf of the resource allocation." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcDuration" />
				<IfcSimplePropertyTemplate id="ScrapFactor_3ThF60qTeHuO00025QrE$V" GlobalId="3ThF60qTeHuO00025QrE$V" Name="ScrapFactor" Description="Sheet metal scrap factor." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="ScreenDiameter_1Ajem0qSSHuO00025QrE$V" GlobalId="1Ajem0qSSHuO00025QrE$V" Name="ScreenDiameter" Description="The diameter of the screen around an object (if present)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="SealType_31DmCfobH23ezb7so63KdY" GlobalId="31DmCfobH23ezb7so63KdY" Name="SealType" Description="Specifies the type of seal." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_SealType">
						<EnumerationValues>
							<IfcLabel-wrapper>COMPRESSIBLE</IfcLabel-wrapper>
							<IfcLabel-wrapper>HYDRO_EXPANDING</IfcLabel-wrapper>
							<IfcLabel-wrapper>MIXED</IfcLabel-wrapper>
							<IfcLabel-wrapper>MEMBRANE</IfcLabel-wrapper>
							<IfcLabel-wrapper>INFLATABLE</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="SeatingHeight_3AeHu0qUWHuO00025QrE$V" GlobalId="3AeHu0qUWHuO00025QrE$V" Name="SeatingHeight" Description="The value of seating height if the chair height is not adjustable." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="SecondaryAirFlowRateRange_3RFPu0qS0HuO00025QrE$V" GlobalId="3RFPu0qS0HuO00025QrE$V" Name="SecondaryAirFlowRateRange" Description="possible range of secondary airflow that can be delivered." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="SecondaryApparentPower_29SJG0qX4HuO00025QrE$V" GlobalId="29SJG0qX4HuO00025QrE$V" Name="SecondaryApparentPower" Description="The power in VA (volt ampere) that has been transformed and is running out of the transformer on the secondary side." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="SecondaryCurrent_1n0Hc0qX4HuO00025QrE$V" GlobalId="1n0Hc0qX4HuO00025QrE$V" Name="SecondaryCurrent" Description="The current that has been transformed and is running out of the transformer on the secondary side." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="SecondaryCurrentType_2Kn5_0qX4HuO00025QrE$V" GlobalId="2Kn5_0qX4HuO00025QrE$V" Name="SecondaryCurrentType" Description="A list of the secondary current types that can result from transformer output." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_SecondaryCurrentType">
						<EnumerationValues>
							<IfcLabel-wrapper>AC</IfcLabel-wrapper>
							<IfcLabel-wrapper>DC</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="SecondaryFrequency_1_7WY0qX4HuO00025QrE$V" GlobalId="1_7WY0qX4HuO00025QrE$V" Name="SecondaryFrequency" Description="The frequency that has been transformed and is running out of the transformer on the secondary side." TemplateType="p_singlevalue" PrimaryMeasureType="IfcFrequencyMeasure" />
				<IfcSimplePropertyTemplate id="SecondarySurfaceArea_0QlBW0qSeHuO00025QrE$V" GlobalId="0QlBW0qSeHuO00025QrE$V" Name="SecondarySurfaceArea" Description="Secondary heat transfer surface area created by fins." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAreaMeasure" />
				<IfcSimplePropertyTemplate id="SecondaryVoltage_1ZIvG0qX4HuO00025QrE$V" GlobalId="1ZIvG0qX4HuO00025QrE$V" Name="SecondaryVoltage" Description="The voltage that has been transformed and is running out of the transformer on the secondary side." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricVoltageMeasure" />
				<IfcSimplePropertyTemplate id="SecondCurvatureRadius_0qWEu0qX0HuO00025QrE$V" GlobalId="0qWEu0qX0HuO00025QrE$V" Name="SecondCurvatureRadius" Description="SecondCurvatureRadius should be defined as the top or right side radius of curvature value." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="SecondCurvatureRadius_2IhT40qX0HuO00025QrE$V" GlobalId="2IhT40qX0HuO00025QrE$V" Name="SecondCurvatureRadius" Description="SecondCurvatureRadius should be defined as the top or right side radius of curvature value." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="SecondMullionOffset_03UAKEgVLDQg8tMaHW3vDr" GlobalId="03UAKEgVLDQg8tMaHW3vDr" Name="SecondMullionOffset" Description="Offset of the mullion centerline for the second mullion, measured along the x-axis of the window placement co-ordinate system. An offset value = 0.666 indicates that the second mullion is positioned at two/third of the window." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="SecondTransomOffset_2kBLHfMdz1sR5512bDOKd_" GlobalId="2kBLHfMdz1sR5512bDOKd_" Name="SecondTransomOffset" Description="Offset of the transom centerline for the second transom, measured along the x-axis of the window placement co-ordinate system. An offset value = 0.666 indicates that the second transom is positioned at two/third of the window." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="SectioningDeviceType_1jE33PRSX1EQ4q4oa7Kb3F" GlobalId="1jE33PRSX1EQ4q4oa7Kb3F" Name="SectioningDeviceType" Description="Indicates the sectioning device type." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_SectioningDeviceType">
						<EnumerationValues>
							<IfcLabel-wrapper>DIFFERENT_POWER_SUPPLY_SEPARATION</IfcLabel-wrapper>
							<IfcLabel-wrapper>PHASE_SEPARATION</IfcLabel-wrapper>
							<IfcLabel-wrapper>SAME_FEEDING_SECTION_SEPARATION</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="SectionLength_349fo0qX0HuO00025QrE$V" GlobalId="349fo0qX0HuO00025QrE$V" Name="SectionLength" Description="The length of a section used in the construction of the tank." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="SectionWidth_3D5su0qX0HuO00025QrE$V" GlobalId="3D5su0qX0HuO00025QrE$V" Name="SectionWidth" Description="The width of a section used in the construction of the tank." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="SecurityLightingType_3rsJo0qUiHuO00025QrE$V" GlobalId="3rsJo0qUiHuO00025QrE$V" Name="SecurityLightingType" Description="The type of security lighting." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_LightFixtureSecurityLightingType">
						<EnumerationValues>
							<IfcLabel-wrapper>SAFETYLIGHT</IfcLabel-wrapper>
							<IfcLabel-wrapper>WARNINGLIGHT</IfcLabel-wrapper>
							<IfcLabel-wrapper>EMERGENCYEXITLIGHT</IfcLabel-wrapper>
							<IfcLabel-wrapper>BLUEILLUMINATION</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="SecurityRating_2qG9M0qTiHuO00025QrE$V" GlobalId="2qG9M0qTiHuO00025QrE$V" Name="SecurityRating" Description="Index based rating system indicating security level.
It is giving according to the national building code." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="SecurityRating_36ZFI0qXWHuO00025QrE$V" GlobalId="36ZFI0qXWHuO00025QrE$V" Name="SecurityRating" Description="Index based rating system indicating security level.
It is giving according to the national building code." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="SeicheRange_0ZDnfixqv4xRd7BBGSw4Uy" GlobalId="0ZDnfixqv4xRd7BBGSw4Uy" Name="SeicheRange" Description="Indicative (95%-100%) range between peaks and troughts of seiche (resonant) waves." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="SeismicResistance_17fvYJ58159gRnjvJMIylv" GlobalId="17fvYJ58159gRnjvJMIylv" Name="SeismicResistance" Description="Maximum magnitude of earthquake that the equipment complies with. The value indicates earthquake intensity measured in Richter scale." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="SelectorType_1Zbc00qWuHuO00025QrE$V" GlobalId="1Zbc00qWuHuO00025QrE$V" Name="SelectorType" Description="A list of the available types of selector switch from which that required may be selected." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i798" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="SelfClosing_2_hry0qTmHuO00025QrE$V" GlobalId="2_hry0qTmHuO00025QrE$V" Name="SelfClosing" Description="Indication whether this object is designed to close automatically after use (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="SelfExtinguishing60332_1_2JRaK0qSSHuO00025QrE$V" GlobalId="2JRaK0qSSHuO00025QrE$V" Name="SelfExtinguishing60332_1" Description="Self Extinguishing cable/core according to IEC 60332.1." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="SelfExtinguishing60332_1_2sJIa0qSWHuO00025QrE$V" GlobalId="2sJIa0qSWHuO00025QrE$V" Name="SelfExtinguishing60332_1" Description="Self Extinguishing cable/core according to IEC 60332.1." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="SelfExtinguishing60332_3_2PP2O0qSSHuO00025QrE$V" GlobalId="2PP2O0qSSHuO00025QrE$V" Name="SelfExtinguishing60332_3" Description="Self Extinguishing cable/core according to IEC 60332.3." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="SelfExtinguishing60332_3_2xgdE0qSWHuO00025QrE$V" GlobalId="2xgdE0qSWHuO00025QrE$V" Name="SelfExtinguishing60332_3" Description="Self Extinguishing cable/core according to IEC 60332.3." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="SelfTestFunction_0D62e0qUmHuO00025QrE$V" GlobalId="0D62e0qUmHuO00025QrE$V" Name="SelfTestFunction" Description="The type of self test function." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_SelfTestType">
						<EnumerationValues>
							<IfcLabel-wrapper>CENTRAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>LOCAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>NONE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="SensibleCoolingCapacity_1QMy80qXCHuO00025QrE$V" GlobalId="1QMy80qXCHuO00025QrE$V" Name="SensibleCoolingCapacity" Description="Sensible cooling capacity." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="SensibleEffectiveness_1WT8C0qS0HuO00025QrE$V" GlobalId="1WT8C0qS0HuO00025QrE$V" Name="SensibleEffectiveness" Description="Sensible heat transfer effectiveness, where effectiveness is defined as the ratio of heat transfer to maximum possible heat transfer." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="SensibleEffectivenessTable_1_sdw0qS0HuO00025QrE$V" GlobalId="1_sdw0qS0HuO00025QrE$V" Name="SensibleEffectivenessTable" Description="Sensible heat transfer effectiveness curve as a function of the primary and secondary air flow rate." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" />
				<IfcSimplePropertyTemplate id="SensibleHeatGain_0cGHfXw5PB$gkctkiMORlw" GlobalId="0cGHfXw5PB$gkctkiMORlw" Name="SensibleHeatGain" Description="The sensible heat or energy gained by the space during the peak conditions." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="SensibleHeatRatio_0yjZg0qSeHuO00025QrE$V" GlobalId="0yjZg0qSeHuO00025QrE$V" Name="SensibleHeatRatio" Description="Air-side sensible heat ratio, or fraction of sensible heat transfer to the total heat transfer." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="SensibleHeatTransferRate_1pXrC0qS0HuO00025QrE$V" GlobalId="1pXrC0qS0HuO00025QrE$V" Name="SensibleHeatTransferRate" Description="Sensible heat transfer rate." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="SensibleHeatTransferRate_1VL4s0qU8HuO00025QrE$V" GlobalId="1VL4s0qU8HuO00025QrE$V" Name="SensibleHeatTransferRate" Description="Sensible heat transfer rate.

Sensible heat transfer rate to primary air flow." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="SensibleLoadToRadiant_3gXX40qUiHuO00025QrE$V" GlobalId="3gXX40qUiHuO00025QrE$V" Name="SensibleLoadToRadiant" Description="Percent of sensible thermal load to radiant heat." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="Sensitivity_1IHLU0qVuHuO00025QrE$V" GlobalId="1IHLU0qVuHuO00025QrE$V" Name="Sensitivity" Description="Sensitivity.

Current leakage to an unwanted leading path during normal operation (IEC 151-14-49)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="Sensitivity_3c_uM0qVqHuO00025QrE$V" GlobalId="3c_uM0qVqHuO00025QrE$V" Name="Sensitivity" Description="Sensitivity.

The rated rms value of the vector sum of the instantaneous currents flowing in the main circuits of the device which causes the device to operate under specified conditions. (IEC 61008-1)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="SeparationType_1cC8_0qUKHuO00025QrE$V" GlobalId="1cC8_0qUKHuO00025QrE$V" Name="SeparationType" Description="Air particulate filter media separation type." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_FilterAirParticleFilterSeparationType">
						<EnumerationValues>
							<IfcLabel-wrapper>BAG</IfcLabel-wrapper>
							<IfcLabel-wrapper>PLEAT</IfcLabel-wrapper>
							<IfcLabel-wrapper>TREADSEPARATION</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="SequenceInTrackPanel_2AwvXjv7r7LvJK8xaTQN3z" GlobalId="2AwvXjv7r7LvJK8xaTQN3z" Name="SequenceInTrackPanel" Description="Sequence of the sleeper within the track panel." TemplateType="p_singlevalue" PrimaryMeasureType="IfcInteger" />
				<IfcSimplePropertyTemplate id="SequentialCode_1rZx8VDW987QxAxZ64yNea" GlobalId="1rZx8VDW987QxAxZ64yNea" Name="SequentialCode" Description="Indicates the sequential code of the cable or wire." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="SerialInterfaceType_0IV69mrp50xeArXDuk$7Y6" GlobalId="0IV69mrp50xeArXDuk$7Y6" Name="SerialInterfaceType" Description="Indicates the type of serial interface used by the device." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_SerialInterfaceType">
						<EnumerationValues>
							<IfcLabel-wrapper>RS_232</IfcLabel-wrapper>
							<IfcLabel-wrapper>RS_422</IfcLabel-wrapper>
							<IfcLabel-wrapper>RS_485</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="SerialNumber_18jl80qVGHuO00025QrE$V" GlobalId="18jl80qVGHuO00025QrE$V" Name="SerialNumber" Description="The manufacturer&apos;s serial number assigned to an occurrence of a product." TemplateType="p_singlevalue" PrimaryMeasureType="IfcIdentifier" />
				<IfcSimplePropertyTemplate id="SerialNumber_1MQ7c0qUmHuO00025QrE$V" GlobalId="1MQ7c0qUmHuO00025QrE$V" Name="SerialNumber" Description="The manufacturer&apos;s serial number assigned to an occurrence of a product." TemplateType="p_singlevalue" PrimaryMeasureType="IfcIdentifier" />
				<IfcSimplePropertyTemplate id="ServiceLifeDuration_3gtzM0qWOHuO00025QrE$V" GlobalId="3gtzM0qWOHuO00025QrE$V" Name="ServiceLifeDuration" Description="The length or duration of a service life.The lower bound indicates pessimistic service life, the upper bound indicates optimistic service life, and the setpoint indicates the typical service life." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcDuration" />
				<IfcSimplePropertyTemplate id="SetbackDistance_11mhm0qS4HuO00025QrE$V" GlobalId="11mhm0qS4HuO00025QrE$V" Name="SetbackDistance" Description="Setback distance from the point of connection on the major element along the axis of the minor element (e.g. distance from a public road at which the line of sigfht is measured." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="SetPoint_0QbDg0qXCHuO00025QrE$V" GlobalId="0QbDg0qXCHuO00025QrE$V" Name="SetPoint" Description="Indicates the setpoint and label.

Indicates the temperature setpoint. For thermostats with setbacks or separate high and low setpoints, then the time series may contain a pair of values at each entry where the first value is the heating setpoint (low) and the second value is the cooling setpoint (high)." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcIdentifier" />
				<IfcSimplePropertyTemplate id="SetPoint_3YrsG0qWqHuO00025QrE$V" GlobalId="3YrsG0qWqHuO00025QrE$V" Name="SetPoint" Description="Indicates the setpoint and label.

For toggle switches, there are two positions, 0 for off and 1 for on.  For dimmer switches, the values may indicate the fully-off and full-on positions, where missing integer values in between are interpolated.   For selector switches, the range indicates the available positions.
An IfcTable may be attached (using IfcMetric and IfcResourceConstraintRelationship) containing columns of the specified header names and types:
&apos;Position&apos; (IfcInteger): The discrete setpoint level.
&apos;Sink&apos; (IfcLabel): The Name of the switched input port (IfcDistributionPort with FlowDirection=SINK).
&apos;Source&apos; (IfcLabel): The Name of the switched output port (IfcDistributionPort with FlowDirection=SOURCE).
&apos;Ratio&apos; (IfcNormalisedRatioMeasure): The ratio of power at the setpoint where 0.0 is off and 1.0 is fully on." TemplateType="p_tablevalue" PrimaryMeasureType="IfcInteger" SecondaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="SetPointCO2Concentration_3agmoOX1T89fmGtUyWkrgf" GlobalId="3agmoOX1T89fmGtUyWkrgf" Name="SetPointCO2Concentration" Description="The carbon dioxide concentration to be sensed. Use IfcPropertyBoundedValue.SetPointValue to set the set point value." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="SetPointConcentration_1HO$G0qWKHuO00025QrE$V" GlobalId="1HO$G0qWKHuO00025QrE$V" Name="SetPointConcentration" Description="The concentration to be sensed. Use IfcPropertyBoundedValue.SetPointValue to set the set point value." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="SetPointConductance_06IU40qWKHuO00025QrE$V" GlobalId="06IU40qWKHuO00025QrE$V" Name="SetPointConductance" Description="The fill level value to be sensed. Use IfcPropertyBoundedValue.SetPointValue to set the set point value." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcElectricConductanceMeasure" />
				<IfcSimplePropertyTemplate id="SetPointContact_0IpZc0qWKHuO00025QrE$V" GlobalId="0IpZc0qWKHuO00025QrE$V" Name="SetPointContact" Description="The contact value to be sensed. Use IfcPropertyBoundedValue.SetPointValue to set the set point value." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcInteger" />
				<IfcSimplePropertyTemplate id="SetPointFlow_0w9GQ0qWKHuO00025QrE$V" GlobalId="0w9GQ0qWKHuO00025QrE$V" Name="SetPointFlow" Description="The volumetric flow value to be sensed. Use IfcPropertyBoundedValue.SetPointValue to set the set point value." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="SetPointFrost_0iQ5Kw98r0C9GuEQY0RhrH" GlobalId="0iQ5Kw98r0C9GuEQY0RhrH" Name="SetPointFrost" Description="The detection of frost." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="SetPointHistory_1RFYK0qWuHuO00025QrE$V" GlobalId="1RFYK0qWuHuO00025QrE$V" Name="SetPointHistory" Description="Indicates the switch position over time according to Pset_SwitchingDeviceTypeCommon.SetPoint." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcInteger" />
				<IfcSimplePropertyTemplate id="SetPointHumidity_2ce0M0qWKHuO00025QrE$V" GlobalId="2ce0M0qWKHuO00025QrE$V" Name="SetPointHumidity" Description="The humidity value to be sensed. Use IfcPropertyBoundedValue.SetPointValue to set the set point value." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="SetPointIdentifier_1Hi710k957tQNt0RZYHhzY" GlobalId="1Hi710k957tQNt0RZYHhzY" Name="SetPointIdentifier" Description="The detected tag value." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcIdentifier" />
				<IfcSimplePropertyTemplate id="SetPointIlluminance_3XeZa0qWKHuO00025QrE$V" GlobalId="3XeZa0qWKHuO00025QrE$V" Name="SetPointIlluminance" Description="The illuminance value to be sensed. Use IfcPropertyBoundedValue.SetPointValue to set the set point value." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcIlluminanceMeasure" />
				<IfcSimplePropertyTemplate id="SetPointIonConcentration_2yhSO0qWKHuO00025QrE$V" GlobalId="2yhSO0qWKHuO00025QrE$V" Name="SetPointIonConcentration" Description="The ion concentration value to be sensed. Use IfcPropertyBoundedValue.SetPointValue to set the set point value." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcIonConcentrationMeasure" />
				<IfcSimplePropertyTemplate id="SetPointLevel_39ohK0qWKHuO00025QrE$V" GlobalId="39ohK0qWKHuO00025QrE$V" Name="SetPointLevel" Description="The fill level value to be sensed. Use IfcPropertyBoundedValue.SetPointValue to set the set point value." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="SetPointMoisture_3k9f60qWKHuO00025QrE$V" GlobalId="3k9f60qWKHuO00025QrE$V" Name="SetPointMoisture" Description="The moisture value to be sensed. Use IfcPropertyBoundedValue.SetPointValue to set the set point value." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="SetPointMovement_09aPo0qWOHuO00025QrE$V" GlobalId="09aPo0qWOHuO00025QrE$V" Name="SetPointMovement" Description="The movement to be sensed." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="SetPointPH_0P4EM0qWOHuO00025QrE$V" GlobalId="0P4EM0qWOHuO00025QrE$V" Name="SetPointPH" Description="The fill level value to be sensed. Use IfcPropertyBoundedValue.SetPointValue to set the set point value." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPHMeasure" />
				<IfcSimplePropertyTemplate id="SetPointPressure_0cBTI0qWOHuO00025QrE$V" GlobalId="0cBTI0qWOHuO00025QrE$V" Name="SetPointPressure" Description="The pressure value to be sensed. Use IfcPropertyBoundedValue.SetPointValue to set the set point value." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="SetPointRadiation_0yr2k0qWOHuO00025QrE$V" GlobalId="0yr2k0qWOHuO00025QrE$V" Name="SetPointRadiation" Description="The radiation power value to be sensed. Use IfcPropertyBoundedValue.SetPointValue to set the set point value." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="SetPointRadioactivity_1Bkju0qWOHuO00025QrE$V" GlobalId="1Bkju0qWOHuO00025QrE$V" Name="SetPointRadioactivity" Description="The radioactivity value to be sensed. Use IfcPropertyBoundedValue.SetPointValue to set the set point value." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcRadioActivityMeasure" />
				<IfcSimplePropertyTemplate id="SetPointSound_1qGjW0qWOHuO00025QrE$V" GlobalId="1qGjW0qWOHuO00025QrE$V" Name="SetPointSound" Description="The sound pressure value to be sensed. Use IfcPropertyBoundedValue.SetPointValue to set the set point value." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcSoundPressureMeasure" />
				<IfcSimplePropertyTemplate id="SetPointSpeed_2sR1c0qWOHuO00025QrE$V" GlobalId="2sR1c0qWOHuO00025QrE$V" Name="SetPointSpeed" Description="The wind speed value to be sensed. Use IfcPropertyBoundedValue.SetPointValue to set the set point value." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLinearVelocityMeasure" />
				<IfcSimplePropertyTemplate id="SetPointTemperature_24feC0qWKHuO00025QrE$V" GlobalId="24feC0qWKHuO00025QrE$V" Name="SetPointTemperature" Description="The temperature value to be sensed. Use IfcPropertyBoundedValue.SetPointValue to set the set point value." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="SetPointTemperature_2JGMe0qWOHuO00025QrE$V" GlobalId="2JGMe0qWOHuO00025QrE$V" Name="SetPointTemperature" Description="The temperature value to be sensed. Use IfcPropertyBoundedValue.SetPointValue to set the set point value." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="SettlementBehaviour_0aIsBh0U1FvRDCb7jNj9zg" GlobalId="0aIsBh0U1FvRDCb7jNj9zg" Name="SettlementBehaviour" Description="Estimate of the settlement/compaction behaviour of the stratum." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="Severity_3phRY0qS0HuO00025QrE$V" GlobalId="3phRY0qS0HuO00025QrE$V" Name="Severity" Description="Indicates alarm severity over time, where the scale of values is determined by the control system configuration. A zero value indicates no present alarm." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcInteger" />
				<IfcSimplePropertyTemplate id="ShadingCoefficient_2Lsvc0qTqHuO00025QrE$V" GlobalId="2Lsvc0qTqHuO00025QrE$V" Name="ShadingCoefficient" Description="(SC): The measure of the ability of a glazing to transmit solar heat, relative to that ability for 3 mm (1/8-inch) clear, double-strength, single glass. Shading coefficient is being phased out in favor of the solar heat gain coefficient (SHGC), and is approximately equal to the SHGC multiplied by 1.15. The shading coefficient is expressed as a number without units between 0 and 1." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="ShadingDeviceType_1TwKm0qWSHuO00025QrE$V" GlobalId="1TwKm0qWSHuO00025QrE$V" Name="ShadingDeviceType" Description="Specifies the type of shading device." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ElementShading">
						<EnumerationValues>
							<IfcLabel-wrapper>FIXED</IfcLabel-wrapper>
							<IfcLabel-wrapper>MOVABLE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OVERHANG</IfcLabel-wrapper>
							<IfcLabel-wrapper>SIDEFIN</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ShaftPower_3qu_C0qSeHuO00025QrE$V" GlobalId="3qu_C0qSeHuO00025QrE$V" Name="ShaftPower" Description="The actual shaft power input to the compressor." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="ShaftPowerRate_0mFjk0qUGHuO00025QrE$V" GlobalId="0mFjk0qUGHuO00025QrE$V" Name="ShaftPowerRate" Description="Fan shaft power." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="Shape_1Sbo_0qSKHuO00025QrE$V" GlobalId="1Sbo_0qSKHuO00025QrE$V" Name="Shape" Description="The shape form of the provision for void, the minimum set of agreed values includes &apos;Rectangle&apos;, &apos;Round&apos;, and &apos;Undefined&apos;." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ShapeDescription_2IOGO0qWyHuO00025QrE$V" GlobalId="2IOGO0qWyHuO00025QrE$V" Name="ShapeDescription" Description="A description of the shape of the work surface e.g. corner square, rectangle, etc." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ShapeType_2kddm0qUeHuO00025QrE$V" GlobalId="2kddm0qUeHuO00025QrE$V" Name="ShapeType" Description="Shape of the junction box." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_JunctionBoxShapeType">
						<EnumerationValues>
							<IfcLabel-wrapper>RECTANGULAR</IfcLabel-wrapper>
							<IfcLabel-wrapper>ROUND</IfcLabel-wrapper>
							<IfcLabel-wrapper>SLOT</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ShearAreaY_0KaG20qVSHuO00025QrE$V" GlobalId="0KaG20qVSHuO00025QrE$V" Name="ShearAreaY" Description="Area of the profile for calculating the shear stress due to shear force parallel to the section analysis axis ys. For example measured in mm². If given, the shear area ys shall be non-negative." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAreaMeasure" />
				<IfcSimplePropertyTemplate id="ShearAreaZ_0Be2y0qVSHuO00025QrE$V" GlobalId="0Be2y0qVSHuO00025QrE$V" Name="ShearAreaZ" Description="Area of the profile for calculating the shear stress due to shear force parallel to the section analysis axis zs. For example measured in mm². If given, the shear area zs shall be non-negative." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAreaMeasure" />
				<IfcSimplePropertyTemplate id="ShearCentreY_2VlSQ0qVOHuO00025QrE$V" GlobalId="2VlSQ0qVOHuO00025QrE$V" Name="ShearCentreY" Description="Location of the profile&apos;s shear centre, measured along ys." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="ShearCentreZ_2PBqy0qVOHuO00025QrE$V" GlobalId="2PBqy0qVOHuO00025QrE$V" Name="ShearCentreZ" Description="Location of the profile&apos;s shear centre, measured along zs." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="ShearDeformationAreaY_3NnGc0qVOHuO00025QrE$V" GlobalId="3NnGc0qVOHuO00025QrE$V" Name="ShearDeformationAreaY" Description="Area of the profile for calculating the shear deformation due to a shear force parallel to ys. For example measured in mm². If given, the shear deformation area ys shall be non-negative." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAreaMeasure" />
				<IfcSimplePropertyTemplate id="ShearDeformationAreaZ_3G1MK0qVOHuO00025QrE$V" GlobalId="3G1MK0qVOHuO00025QrE$V" Name="ShearDeformationAreaZ" Description="Area of the profile for calculating the shear deformation due to a shear force parallel to zs. For example measured in mm². If given, the shear deformation area zs shall be non-negative." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAreaMeasure" />
				<IfcSimplePropertyTemplate id="ShearModulus_0FEmIVJej8$PCIj$EUMR5y" GlobalId="0FEmIVJej8$PCIj$EUMR5y" Name="ShearModulus" Description="Shear modulus, mean value." TemplateType="p_singlevalue" PrimaryMeasureType="IfcModulusOfElasticityMeasure" />
				<IfcSimplePropertyTemplate id="ShearModulus_0G5QhnJy98DR0OMDpbIwLY" GlobalId="0G5QhnJy98DR0OMDpbIwLY" Name="ShearModulus" Description="Shear modulus, mean value." TemplateType="p_singlevalue" PrimaryMeasureType="IfcModulusOfElasticityMeasure" />
				<IfcSimplePropertyTemplate id="ShearModulus_0LyBqEuor3xhVDmdpBBrhS" GlobalId="0LyBqEuor3xhVDmdpBBrhS" Name="ShearModulus" Description="Shear modulus, mean value." TemplateType="p_singlevalue" PrimaryMeasureType="IfcModulusOfElasticityMeasure" />
				<IfcSimplePropertyTemplate id="ShearModulus_1BsSTJE8H2BfNbyA5ERUcQ" GlobalId="1BsSTJE8H2BfNbyA5ERUcQ" Name="ShearModulus" Description="Shear modulus." TemplateType="p_singlevalue" PrimaryMeasureType="IfcModulusOfElasticityMeasure" />
				<IfcSimplePropertyTemplate id="ShearModulus_20Rck0qUqHuO00025QrE$V" GlobalId="20Rck0qUqHuO00025QrE$V" Name="ShearModulus" Description="A measure of the shear modulus of elasticity of the material." TemplateType="p_singlevalue" PrimaryMeasureType="IfcModulusOfElasticityMeasure" />
				<IfcSimplePropertyTemplate id="ShearModulus_2L1buM9pLFHP0$3z2RXBXH" GlobalId="2L1buM9pLFHP0$3z2RXBXH" Name="ShearModulus" Description="Shear modulus." TemplateType="p_singlevalue" PrimaryMeasureType="IfcModulusOfElasticityMeasure" />
				<IfcSimplePropertyTemplate id="ShearModulus_3mRDnvHKH5pfCYGaCWPwEu" GlobalId="3mRDnvHKH5pfCYGaCWPwEu" Name="ShearModulus" Description="Shear modulus." TemplateType="p_singlevalue" PrimaryMeasureType="IfcModulusOfElasticityMeasure" />
				<IfcSimplePropertyTemplate id="ShearModulusMin_0BABvT9ifCweKQpbVbmW1v" GlobalId="0BABvT9ifCweKQpbVbmW1v" Name="ShearModulusMin" Description="Shear modulus, minimal value." TemplateType="p_singlevalue" PrimaryMeasureType="IfcModulusOfElasticityMeasure" />
				<IfcSimplePropertyTemplate id="ShearModulusMin_2cuG8RJdnEhhN8yxbhfbVX" GlobalId="2cuG8RJdnEhhN8yxbhfbVX" Name="ShearModulusMin" Description="Shear modulus, minimal value." TemplateType="p_singlevalue" PrimaryMeasureType="IfcModulusOfElasticityMeasure" />
				<IfcSimplePropertyTemplate id="ShearModulusMin_3eMkkJs1v8TQccVqGUM$iA" GlobalId="3eMkkJs1v8TQccVqGUM$iA" Name="ShearModulusMin" Description="Shear modulus, minimal value." TemplateType="p_singlevalue" PrimaryMeasureType="IfcModulusOfElasticityMeasure" />
				<IfcSimplePropertyTemplate id="ShearStrength_0kjgupy_97avIlMZH_iBD4" GlobalId="0kjgupy_97avIlMZH_iBD4" Name="ShearStrength" Description="Shear strength." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="ShearStrength_0t2jQXJuD8tQVtmTYGBx9q" GlobalId="0t2jQXJuD8tQVtmTYGBx9q" Name="ShearStrength" Description="Defining values: α; defined values: shear strength." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositivePlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="ShearStrength_1AG3tFK1rEUBNEvoZ2jg2s" GlobalId="1AG3tFK1rEUBNEvoZ2jg2s" Name="ShearStrength" Description="Defining values: α; defined values: shear strength." TemplateType="p_tablevalue" PrimaryMeasureType="IfcPositivePlaneAngleMeasure" SecondaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="ShearStrength_2hFML4Q9j91f5aJi28rNwe" GlobalId="2hFML4Q9j91f5aJi28rNwe" Name="ShearStrength" Description="Shear strength." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="ShearStrength_2NP$qunRvDaBTXazkik1TE" GlobalId="2NP$qunRvDaBTXazkik1TE" Name="ShearStrength" Description="Shear strength." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="ShearStrength_3TzBr2hBjEE9H1QHei6UZg" GlobalId="3TzBr2hBjEE9H1QHei6UZg" Name="ShearStrength" Description="Defining values: α; defined values: shear strength." TemplateType="p_tablevalue" PrimaryMeasureType="IfcPositivePlaneAngleMeasure" SecondaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="SheathColours_2IYUC0qSWHuO00025QrE$V" GlobalId="2IYUC0qSWHuO00025QrE$V" Name="SheathColours" Description="Colour of the core (derived from IEC 60757). Note that the combined color &apos;GreenAndYellow&apos; shall be used only as Protective Earth (PE) conductors according to the requirements of IEC 60446." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_CoreColoursEnum">
						<EnumerationValues>
							<IfcLabel-wrapper>BLACK</IfcLabel-wrapper>
							<IfcLabel-wrapper>BLUE</IfcLabel-wrapper>
							<IfcLabel-wrapper>BROWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>GOLD</IfcLabel-wrapper>
							<IfcLabel-wrapper>GREEN</IfcLabel-wrapper>
							<IfcLabel-wrapper>GREY</IfcLabel-wrapper>
							<IfcLabel-wrapper>ORANGE</IfcLabel-wrapper>
							<IfcLabel-wrapper>PINK</IfcLabel-wrapper>
							<IfcLabel-wrapper>RED</IfcLabel-wrapper>
							<IfcLabel-wrapper>SILVER</IfcLabel-wrapper>
							<IfcLabel-wrapper>TURQUOISE</IfcLabel-wrapper>
							<IfcLabel-wrapper>VIOLET</IfcLabel-wrapper>
							<IfcLabel-wrapper>WHITE</IfcLabel-wrapper>
							<IfcLabel-wrapper>YELLOW</IfcLabel-wrapper>
							<IfcLabel-wrapper>GREENANDYELLOW</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="SheathDiameter_3oEHCHEBvA8PGa16tDeoQ3" GlobalId="3oEHCHEBvA8PGa16tDeoQ3" Name="SheathDiameter" Description="Diameter of the sheeth (duct) around the tendon, if there is one with this type of tendon." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ShieldConductorDiameter_1as$loCX107Pk6vf9GXkJu" GlobalId="1as$loCX107Pk6vf9GXkJu" Name="ShieldConductorDiameter" Description="Indicates the shielded conductor diameter. It is only used for coaxial wire pair." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ShipLoading_1QIfuyRDnEaQu6kbYym8p3" GlobalId="1QIfuyRDnEaQu6kbYym8p3" Name="ShipLoading" Description="Ship loading force" TemplateType="p_singlevalue" PrimaryMeasureType="IfcForceMeasure" />
				<IfcSimplePropertyTemplate id="ShipMethod_3hlJi0qVSHuO00025QrE$V" GlobalId="3hlJi0qVSHuO00025QrE$V" Name="ShipMethod" Description="Method of shipping that will be used for goods or services." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="ShortCircuit1PoleMaximumState_1saZk0qU0HuO00025QrE$V" GlobalId="1saZk0qU0HuO00025QrE$V" Name="ShortCircuit1PoleMaximumState" Description="Maximum 1 pole short circuit current provided at the point of supply i.e. the fault between 1 phase and N." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="ShortCircuit1PoleMinimumState_23hog0qU0HuO00025QrE$V" GlobalId="23hog0qU0HuO00025QrE$V" Name="ShortCircuit1PoleMinimumState" Description="Minimum 1 pole short circuit current provided at the point of supply i.e. the fault between 1 phase and N." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="ShortCircuit1PolePowerFactorMaximumState_1zkKc0qU0HuO00025QrE$V" GlobalId="1zkKc0qU0HuO00025QrE$V" Name="ShortCircuit1PolePowerFactorMaximumState" Description="Power factor of the maximum 1 pole short circuit current provided at the point of supply i.e. the fault between 1 phase and N." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="ShortCircuit1PolePowerFactorMinimumState_2937K0qU0HuO00025QrE$V" GlobalId="2937K0qU0HuO00025QrE$V" Name="ShortCircuit1PolePowerFactorMinimumState" Description="Power factor of the minimum 1 pole short circuit current provided at the point of supply i.e. the fault between 1 phase and N." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="ShortCircuit2PoleMinimumState_1SM5s0qU0HuO00025QrE$V" GlobalId="1SM5s0qU0HuO00025QrE$V" Name="ShortCircuit2PoleMinimumState" Description="Minimum 2 pole short circuit current provided at the point of supply." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="ShortCircuit2PolePowerFactorMinimumState_1ai9Y0qU0HuO00025QrE$V" GlobalId="1ai9Y0qU0HuO00025QrE$V" Name="ShortCircuit2PolePowerFactorMinimumState" Description="Power factor of the minimum 2 pole short circuit current provided at the point of supply." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="ShortCircuit3PoleMaximumState_1H1J80qU0HuO00025QrE$V" GlobalId="1H1J80qU0HuO00025QrE$V" Name="ShortCircuit3PoleMaximumState" Description="Maximum 3 pole short circuit current provided at the point of supply." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="ShortCircuit3PolePowerFactorMaximumState_1M_nC0qU0HuO00025QrE$V" GlobalId="1M_nC0qU0HuO00025QrE$V" Name="ShortCircuit3PolePowerFactorMaximumState" Description="Power factor of the maximum 3 pole short circuit current provided at the point of supply." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="ShortCircuitCurrent_1b3j84vif64PjMUuaJihze" GlobalId="1b3j84vif64PjMUuaJihze" Name="ShortCircuitCurrent" Description="Short circuit current of the earthing element." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="ShortCircuitVoltage_2Wi260qX4HuO00025QrE$V" GlobalId="2Wi260qX4HuO00025QrE$V" Name="ShortCircuitVoltage" Description="A complex number that specifies the real and imaginary parts of the short-circuit voltage at rated current of a transformer given in %." TemplateType="p_singlevalue" PrimaryMeasureType="IfcComplexNumber" />
				<IfcSimplePropertyTemplate id="Shortening_0CDyO0qVKHuO00025QrE$V" GlobalId="0CDyO0qVKHuO00025QrE$V" Name="Shortening" Description="The ratio of the distance by which a precast piece is shortened after release from its form (due to compression induced by prestressing) to its original (nominal) length." TemplateType="p_singlevalue" PrimaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="ShortInsideCenterLowerBarPitch_2b80w0qW0HuO00025QrE$V" GlobalId="2b80w0qW0HuO00025QrE$V" Name="ShortInsideCenterLowerBarPitch" Description="The pitch length of the short inside center lower bar." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ShortInsideCenterTopBarPitch_1rSGQ0qW0HuO00025QrE$V" GlobalId="1rSGQ0qW0HuO00025QrE$V" Name="ShortInsideCenterTopBarPitch" Description="The pitch length of the short inside center top bar." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ShortInsideEndLowerBarPitch_2itxC0qW0HuO00025QrE$V" GlobalId="2itxC0qW0HuO00025QrE$V" Name="ShortInsideEndLowerBarPitch" Description="The pitch length of the short inside end lower bar." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ShortInsideEndTopBarPitch_1zoK60qW0HuO00025QrE$V" GlobalId="1zoK60qW0HuO00025QrE$V" Name="ShortInsideEndTopBarPitch" Description="The pitch length of the short inside end top bar." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ShortOutsideLowerBarPitch_2SnzE0qW0HuO00025QrE$V" GlobalId="2SnzE0qW0HuO00025QrE$V" Name="ShortOutsideLowerBarPitch" Description="The pitch length of the short outside lower bar." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ShortOutsideTopBarPitch_1kIVY0qW0HuO00025QrE$V" GlobalId="1kIVY0qW0HuO00025QrE$V" Name="ShortOutsideTopBarPitch" Description="The pitch length of the short outside top bar." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ShortTimeCurrentSetValue_1mgl_HOVb9xhMyLHVK14q_" GlobalId="1mgl_HOVb9xhMyLHVK14q_" Name="ShortTimeCurrentSetValue" Description="Short time current set value. The set value of the long time tripping current if adjustable." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="ShortTimeFunction_0pV42acCLEIwfKf4JFHv3g" GlobalId="0pV42acCLEIwfKf4JFHv3g" Name="ShortTimeFunction" Description="Applying short time function A flag indicating that the short time function of the device is used. The value should be set to FALSE for devices not having a short time function, or if the short time function is not selected to be used." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="ShortTimei2tFunction_2h6cR0csPBmv_hfMRK3yFs" GlobalId="2h6cR0csPBmv_hfMRK3yFs" Name="ShortTimei2tFunction" Description="Applying short time i2t function. A flag indicating that the I2t short time function of the device is used. The value should be set to TRUE only if the I2t function  is explicitly selected for the device." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="ShortTimeTrippingTime_1qouBkrlzAhf_8$b8Y1P5d" GlobalId="1qouBkrlzAhf_8$b8Y1P5d" Name="ShortTimeTrippingTime" Description="Short time tripping time. The set value of the short time tripping time if adjustable." TemplateType="p_singlevalue" PrimaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="ShowerHeadDescription_0xxSg0qWCHuO00025QrE$V" GlobalId="0xxSg0qWCHuO00025QrE$V" Name="ShowerHeadDescription" Description="A description of the shower head(s) that emit the spray of water." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="ShowerType_06uNW0qWCHuO00025QrE$V" GlobalId="06uNW0qWCHuO00025QrE$V" Name="ShowerType" Description="Selection of the type of shower from the enumerated list of types where:-

Drench:     Shower that rapidly gives a thorough soaking in an emergency.
Individual:     Shower unit that is typically enclosed and is for the use of one person at a time.
Tunnel:     Shower that has a succession of shower heads or spreaders that operate simultaneously along its length." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ShowerType">
						<EnumerationValues>
							<IfcLabel-wrapper>DRENCH</IfcLabel-wrapper>
							<IfcLabel-wrapper>INDIVIDUAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>TUNNEL</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Side_1IWqwe1DT37ObnUgQI07BF" GlobalId="1IWqwe1DT37ObnUgQI07BF" Name="Side" Description="Specifies if the width is measured to the RIGHT or to the LEFT of the curve referenced by the placement, or if the same value is applied to BOTH sides." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_SideType">
						<EnumerationValues>
							<IfcLabel-wrapper>LEFT</IfcLabel-wrapper>
							<IfcLabel-wrapper>RIGHT</IfcLabel-wrapper>
							<IfcLabel-wrapper>BOTH</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="SideFlatness_0IkMojxkv5NevG5Jf0VoEi" GlobalId="0IkMojxkv5NevG5Jf0VoEi" Name="SideFlatness" Description="Indicative (95%-100%) range flatness associated to the side surface in YZ, if different to the overall flatness." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="SignalAspectType_0E2G9ROg95xwoP5_z_Eeii" GlobalId="0E2G9ROg95xwoP5_z_Eeii" Name="SignalAspectType" Description="The type of aspect, e.g. 2-display aspect for distant signal, 3-display aspect for block signal." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="SignalFactor_1jv3e0qSqHuO00025QrE$V" GlobalId="1jv3e0qSqHuO00025QrE$V" Name="SignalFactor" Description="Factor multiplied onto offset signal." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="SignalFrameBackboardDiameter_19LadSgq58jetZa7IOZtqZ" GlobalId="19LadSgq58jetZa7IOZtqZ" Name="SignalFrameBackboardDiameter" Description="The nominal diameter of the signal frame backboard." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="SignalFrameBackboardHeight_0v1lz2quLCXOlGd9GKfrFH" GlobalId="0v1lz2quLCXOlGd9GKfrFH" Name="SignalFrameBackboardHeight" Description="The nominal height of the signal frame backboard." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="SignalFrameType_0Q2X5ruSX1Nw3$GFV6xLWa" GlobalId="0Q2X5ruSX1Nw3$GFV6xLWa" Name="SignalFrameType" Description="Type of frame, e.g. main frame, route indicator, speed indicator, direction indicator, etc." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="SignalHoodLength_0V5henCzj7ouBew9_bcs0i" GlobalId="0V5henCzj7ouBew9_bcs0i" Name="SignalHoodLength" Description="Nominal length of the signal hood, which is the signal lamp cover against glaring sun." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="SignalIndicatorType_0Shkb4IIr0WOC35qEoq_UO" GlobalId="0Shkb4IIr0WOC35qEoq_UO" Name="SignalIndicatorType" Description="Type of the indicators on a signal, e.g. route indicator, speed restriction indicator etc." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_SignalIndicatorType">
						<EnumerationValues>
							<IfcLabel-wrapper>DEPARTUREINDICATOR</IfcLabel-wrapper>
							<IfcLabel-wrapper>SHUNTINGINDICATOR</IfcLabel-wrapper>
							<IfcLabel-wrapper>SWITCHINDICATOR</IfcLabel-wrapper>
							<IfcLabel-wrapper>ROUTEINDICATOR</IfcLabel-wrapper>
							<IfcLabel-wrapper>DEPARTUREROUTEINDICATOR</IfcLabel-wrapper>
							<IfcLabel-wrapper>ROLLINGSTOCKSTOPINDICATOR</IfcLabel-wrapper>
							<IfcLabel-wrapper>DERAILINDICATOR</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="SignalMessage_0tVDoRl1v74RpBVl3MpeD6" GlobalId="0tVDoRl1v74RpBVl3MpeD6" Name="SignalMessage" Description="All possible message available at this signal, e.g. &quot;3/4- display automatic blocking&quot;." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="SignalOffset_1fk1o0qSqHuO00025QrE$V" GlobalId="1fk1o0qSqHuO00025QrE$V" Name="SignalOffset" Description="Offset constant added to modified signal." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="SignalPostTelephoneID_0NCWcMrUb2H8fwqgBRgcB0" GlobalId="0NCWcMrUb2H8fwqgBRgcB0" Name="SignalPostTelephoneID" Description="The identifier of the signal post telephone attached to the signal." TemplateType="p_singlevalue" PrimaryMeasureType="IfcIdentifier" />
				<IfcSimplePropertyTemplate id="SignalPostTelephoneType_0TSpUzg5H3AAZB2WOvWebT" GlobalId="0TSpUzg5H3AAZB2WOvWebT" Name="SignalPostTelephoneType" Description="Indicates the type of the signal post telephone, e.g. locked, direct line, dial phone." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="SignalSightingAchievableDistance_1NvUvG1d5BFRrtpV4UnXSI" GlobalId="1NvUvG1d5BFRrtpV4UnXSI" Name="SignalSightingAchievableDistance" Description="Reading distance of the signal, which is achievable with the help of mitigation works." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="SignalSightingAvailableDistance_37LmZXPG56MQ4d$oQFgCw0" GlobalId="37LmZXPG56MQ4d$oQFgCw0" Name="SignalSightingAvailableDistance" Description="Reading distance of the signal without having any mitigation works." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="SignalSightingCombinedWithRepeater_1xuTh0Z$T9uAGTWtHgVFHl" GlobalId="1xuTh0Z$T9uAGTWtHgVFHl" Name="SignalSightingCombinedWithRepeater" Description="Combined reading distance for the signal and any associated repeaters." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="SignalSightingMinimum_1oooHdNF9CLwBYFzw5Mlls" GlobalId="1oooHdNF9CLwBYFzw5Mlls" Name="SignalSightingMinimum" Description="Minimal distance in which the signal has to be readable." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="SignalSightingPreferred_3$$GnFzi98gvjNQK5FSUFz" GlobalId="3$$GnFzi98gvjNQK5FSUFz" Name="SignalSightingPreferred" Description="Preferred distance in which the signal shall be readable." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="SignalSightingRouteIndicator_1UzmZKZgT3_egnwLmHjJWR" GlobalId="1UzmZKZgT3_egnwLmHjJWR" Name="SignalSightingRouteIndicator" Description="Required reading distance for the route indicator." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="SignalTime_1ogEu0qSqHuO00025QrE$V" GlobalId="1ogEu0qSqHuO00025QrE$V" Name="SignalTime" Description="Time factor used for integral and running average controllers." TemplateType="p_singlevalue" PrimaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="SignalTimeDecrease_3tb0U0qSqHuO00025QrE$V" GlobalId="3tb0U0qSqHuO00025QrE$V" Name="SignalTimeDecrease" Description="Time factor used for exponential decrease." TemplateType="p_singlevalue" PrimaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="SignalTimeIncrease_3oDhq0qSqHuO00025QrE$V" GlobalId="3oDhq0qSqHuO00025QrE$V" Name="SignalTimeIncrease" Description="Time factor used for exponential increase." TemplateType="p_singlevalue" PrimaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="SignalViewingMinimumInFront_2bEP3oC5z3WBxX9H7BsKu5" GlobalId="2bEP3oC5z3WBxX9H7BsKu5" Name="SignalViewingMinimumInFront" Description="Smallest distance where the signal has to be readable (for train very close to the signal)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="SignalWalkwayLength_2hoc6PPhvELAtWTUyKoQU6" GlobalId="2hoc6PPhvELAtWTUyKoQU6" Name="SignalWalkwayLength" Description="Indicates the length of the walkway from signal to signal post telephone." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="SignLegend_0eTw1IH6j7MugyK0Ib18nX" GlobalId="0eTw1IH6j7MugyK0Ib18nX" Name="SignLegend" Description="Text information written on the signal or sign." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="SiltVolume_0YWCMc_RzDo8BnE1x52QEb" GlobalId="0YWCMc_RzDo8BnE1x52QEb" Name="SiltVolume" Description="Relative volume of silt (typically smaller than 0.063mm) stratum constituents." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumeMeasure" />
				<IfcSimplePropertyTemplate id="SingleChannelAveragePower_3rB$_Tjhz6S8Z3ZXo0VSc6" GlobalId="3rB$_Tjhz6S8Z3ZXo0VSc6" Name="SingleChannelAveragePower" Description="Indicates the average power of a single channel of the transport equipment." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="SingleChannelPower_25tcvQ$vv7RRphaUrbQGbb" GlobalId="25tcvQ$vv7RRphaUrbQGbb" Name="SingleChannelPower" Description="Indicates the power range of a single channel of the transport equipment." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="SingleWaveTransmissionRate_1_gN4QLfz9chfxmU_gcIKe" GlobalId="1_gN4QLfz9chfxmU_gcIKe" Name="SingleWaveTransmissionRate" Description="Indicates the single wave transmission rate of the transport equipment." TemplateType="p_singlevalue" PrimaryMeasureType="IfcFrequencyMeasure" />
				<IfcSimplePropertyTemplate id="SinkType_1JBBW0qWCHuO00025QrE$V" GlobalId="1JBBW0qWCHuO00025QrE$V" Name="SinkType" Description="Selection of the type of sink from the enumerated list of types where:-

Belfast:    Deep sink that has a plain edge and a weir overflow
.
Bucket:     Sink at low level, with protected front edge, that facilitates filling and emptying buckets, usually with a hinged grid on which to stand them.
Cleaners:    Sink, usually fixed at normal height (900mm), with protected front edge.
Combination_Left:    Sink with integral drainer on left hand side
.
Combination_Right: Sink with integral drainer on right hand side
.
Combination_Double:     Sink with integral drainer on both sides
.
Drip: Small sink that catches drips or flow from a faucet
.
Laboratory: Sink, of acid resisting material, with a top edge shaped to facilitate fixing to the underside of a desktop
.
London: Deep sink that has a plain edge and no overflow
.
Plaster: Sink with sediment receiver to prevent waste plaster passing into drains
.
Pot: Large metal sink, with a standing waste, for washing cooking utensils
.
Rinsing: Metal sink in which water can be heated and culinary utensils and tableware immersed at high temperature that destroys most harmful bacteria and allows subsequent self drying.
.
Shelf: Ceramic sink with an integral back shelf through which water fittings are mounted
.
VegetablePreparation:   Large metal sink, with a standing waste, for washing and preparing vegetables
." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_SinkType">
						<EnumerationValues>
							<IfcLabel-wrapper>BELFAST</IfcLabel-wrapper>
							<IfcLabel-wrapper>BUCKET</IfcLabel-wrapper>
							<IfcLabel-wrapper>CLEANERS</IfcLabel-wrapper>
							<IfcLabel-wrapper>COMBINATION_LEFT</IfcLabel-wrapper>
							<IfcLabel-wrapper>COMBINATION_RIGHT</IfcLabel-wrapper>
							<IfcLabel-wrapper>COMBINATION_DOUBLE</IfcLabel-wrapper>
							<IfcLabel-wrapper>DRIP</IfcLabel-wrapper>
							<IfcLabel-wrapper>LABORATORY</IfcLabel-wrapper>
							<IfcLabel-wrapper>LONDON</IfcLabel-wrapper>
							<IfcLabel-wrapper>PLASTER</IfcLabel-wrapper>
							<IfcLabel-wrapper>POT</IfcLabel-wrapper>
							<IfcLabel-wrapper>RINSING</IfcLabel-wrapper>
							<IfcLabel-wrapper>SHELF</IfcLabel-wrapper>
							<IfcLabel-wrapper>VEGETABLEPREPARATION</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="SiteCoverageRatio_3O6T20qWSHuO00025QrE$V" GlobalId="3O6T20qWSHuO00025QrE$V" Name="SiteCoverageRatio" Description="The ratio of the utilization, TotalArea / BuildableArea, expressed as a maximum value. The ratio value may be used to derive BuildableArea." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="Size_1g9zO0qXGHuO00025QrE$V" GlobalId="1g9zO0qXGHuO00025QrE$V" Name="Size" Description="The size of the connection to the valve (or to each connection for faucets, mixing valves, etc.)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="SizingMethod_2o9Gc0qT0HuO00025QrE$V" GlobalId="2o9Gc0qT0HuO00025QrE$V" Name="SizingMethod" Description="Identifies whether the damper is sized nominally or with exact measurements:NOMINAL: Nominal sizing method.
EXACT: Exact sizing method." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_DamperSizingMethod">
						<EnumerationValues>
							<IfcLabel-wrapper>NOMINAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>EXACT</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="SkillLevel_0C6zG0qRqHuO00025QrE$V" GlobalId="0C6zG0qRqHuO00025QrE$V" Name="SkillLevel" Description="Skill level exhibited by the actor and which indicates an extent of their capability to perform actions on the artefacts upon which they can act." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="SkirtingBoard_1jQqq0eYDBaBJh6G7AM_Ar" GlobalId="1jQqq0eYDBaBJh6G7AM_Ar" Name="SkirtingBoard" Description="Label to indicate the material or construction of the skirting board around the space flooring. The label is used for room book information.The material information is provided in absence of an IfcCovering (type=SKIRTINGBOARD) object with own shape representation and material assignment. In case of inconsistency the material assigned to IfcCovering elements takes precedence." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="SkirtingBoardHeight_2l4adt7h95UQhiXngafYXx" GlobalId="2l4adt7h95UQhiXngafYXx" Name="SkirtingBoardHeight" Description="Height of the skirting board.The height information is provided in absence of an IfcCovering (type=SKIRTINGBOARD) object with own shape representation and material assignment. In case of inconsistency the height assigned to IfcCovering elements takes precedence." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="Slaking_1GTIyqmf9Eu8cGgYc0$TFp" GlobalId="1GTIyqmf9Eu8cGgYc0$TFp" Name="Slaking" Description="The crumbling and disintegration of rock or hard soil upon exposure to air or water." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="SleeperArrangement_24pyO2n$n5EOpil0HhjmwF" GlobalId="24pyO2n$n5EOpil0HhjmwF" Name="SleeperArrangement" Description="Define the rail joint sleeper method of assembly (&quot;twin sleeper&quot; type or &quot;between sleepers&quot; type)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_SleeperArrangement">
						<EnumerationValues>
							<IfcLabel-wrapper>TWINSLEEPER</IfcLabel-wrapper>
							<IfcLabel-wrapper>BETWEENSLEEPERS</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="SleeperType_28mz55$2X1V92osWy7KaqR" GlobalId="28mz55$2X1V92osWy7KaqR" Name="SleeperType" Description="Indicates the sleeper type." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_SleeperType">
						<EnumerationValues>
							<IfcLabel-wrapper>WOODENSLEEPER</IfcLabel-wrapper>
							<IfcLabel-wrapper>CONCRETESLEEPER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTINSULATEDSTEELSLEEPER</IfcLabel-wrapper>
							<IfcLabel-wrapper>INSULATEDSTEELSLEEPER</IfcLabel-wrapper>
							<IfcLabel-wrapper>MONOBLOCKCONCRETESLEEPER</IfcLabel-wrapper>
							<IfcLabel-wrapper>TWOBLOCKCONCRETESLEEPER</IfcLabel-wrapper>
							<IfcLabel-wrapper>COMPOSITESLEEPER</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Slope_0UvTS0qSGHuO00025QrE$V" GlobalId="0UvTS0qSGHuO00025QrE$V" Name="Slope" Description="Slope angle - relative to horizontal (0.0 degrees).

The shape information is provided in addition to the shape representation and the geometric parameters used within. In cases of inconsistency between the geometric parameters and the shape properties, provided in the attached property, the geometric parameters take precedence.  For geometry editing applications, like CAD: this value should be write-only." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="Slope_1aRCa0qV4HuO00025QrE$V" GlobalId="1aRCa0qV4HuO00025QrE$V" Name="Slope" Description="Slope angle - relative to horizontal (0.0 degrees).The shape information is provided in addition to the shape representation and the geometric parameters used within. In cases of inconsistency between the geometric parameters and the shape properties, provided in the attached property, the geometric parameters take precedence.  For geometry editing applications, like CAD: this value should be write-only." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="Slope_1hpAm0qSeHuO00025QrE$V" GlobalId="1hpAm0qSeHuO00025QrE$V" Name="Slope" Description="Slope angle - relative to horizontal (0.0 degrees).The shape information is provided in addition to the shape representation and the geometric parameters used within. In cases of inconsistency between the geometric parameters and the shape properties, provided in the attached property, the geometric parameters take precedence.  For geometry editing applications, like CAD: this value should be write-only." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="Slope_2IMGe0qVyHuO00025QrE$V" GlobalId="2IMGe0qVyHuO00025QrE$V" Name="Slope" Description="Slope angle - relative to horizontal (0.0 degrees).The shape information is provided in addition to the shape representation and the geometric parameters used within. In cases of inconsistency between the geometric parameters and the shape properties, provided in the attached property, the geometric parameters take precedence.  For geometry editing applications, like CAD: this value should be write-only." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="Slope_3kjYo0qVCHuO00025QrE$V" GlobalId="3kjYo0qVCHuO00025QrE$V" Name="Slope" Description="Slope angle - relative to horizontal (0.0 degrees).The shape information is provided in addition to the shape representation and the geometric parameters used within. In cases of inconsistency between the geometric parameters and the shape properties, provided in the attached property, the geometric parameters take precedence. For geometry editing applications, like CAD: this value should be write-only.

Angle of the gutter to allow for drainage." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="SlopeAngle_1e_6tKMk1BoO7cfc4MFmey" GlobalId="1e_6tKMk1BoO7cfc4MFmey" Name="SlopeAngle" Description="Inclination of a natural or excavated surface where the observations were made. Angle is measured relative to horizontal (90° is a vertical slope)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="SlopeBaseElevation_3UtmGodEP1kfvXMaxiGM$k" GlobalId="3UtmGodEP1kfvXMaxiGM$k" Name="SlopeBaseElevation" Description="Planned or measured elevation at the base of the mapped slope." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="SlopeHeight_14LE8JSevCsetbtSfTo1C0" GlobalId="14LE8JSevCsetbtSfTo1C0" Name="SlopeHeight" Description="The Height of the Slope(vertical distance from the slope foot)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="SlotLength_2MPJU0qRyHuO00025QrE$V" GlobalId="2MPJU0qRyHuO00025QrE$V" Name="SlotLength" Description="Slot length." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="SlotWidth_2H1_q0qRyHuO00025QrE$V" GlobalId="2H1_q0qRyHuO00025QrE$V" Name="SlotWidth" Description="Slot width." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="SmokeLevel_24x_PWjRXByRIpwhg2SIFm" GlobalId="24x_PWjRXByRIpwhg2SIFm" Name="SmokeLevel" Description="Maximum level of smoke that the equipment complies with. It is provided according to an international or national standard." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="SmokeStop_3Enpw0qTmHuO00025QrE$V" GlobalId="3Enpw0qTmHuO00025QrE$V" Name="SmokeStop" Description="Indication whether the object is designed to provide a smoke stop (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="SmokeStop_3vpuE0qXWHuO00025QrE$V" GlobalId="3vpuE0qXWHuO00025QrE$V" Name="SmokeStop" Description="Indication whether the object is designed to provide a smoke stop (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="SnowSensorMeasureRange_0d_Zd1PZX8FgpMBKTSbIxe" GlobalId="0d_Zd1PZX8FgpMBKTSbIxe" Name="SnowSensorMeasureRange" Description="Indicates the measuring range of snow depth meter." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="SnowSensorType_1ujtLLwfjDxxNkuM8GadCz" GlobalId="1ujtLLwfjDxxNkuM8GadCz" Name="SnowSensorType" Description="Indicates the type of snow depth meter." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_SnowSensorType">
						<EnumerationValues>
							<IfcLabel-wrapper>LASERIRRADIATION</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="SO42_0U5FAS_db4URK3Zf0YMJDR" GlobalId="0U5FAS_db4URK3Zf0YMJDR" Name="SO42-" Description="Content of SO4 2- in the water sample." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="SoffitLevel_2YMlI0qTCHuO00025QrE$V" GlobalId="2YMlI0qTCHuO00025QrE$V" Name="SoffitLevel" Description="Level of the highest internal part of the cross section as measured from ground level." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="SoffitLevel_3yMxe0qTCHuO00025QrE$V" GlobalId="3yMxe0qTCHuO00025QrE$V" Name="SoffitLevel" Description="Level of the highest internal part of the cross section as measured from ground level." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="SoftnessCoefficient_1TpFLgzCzFERpwNsg1t_hP" GlobalId="1TpFLgzCzFERpwNsg1t_hP" Name="SoftnessCoefficient" Description="Vessel flexibility factor - proportion of impact energy absorbed by the hull." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="SoftwareVersion_2mfX80qSqHuO00025QrE$V" GlobalId="2mfX80qSqHuO00025QrE$V" Name="SoftwareVersion" Description="Indicates version of application software according to systems integrator." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="SoilConductivity_0sP2Zz6UL4Lw4ArbLa1rZd" GlobalId="0sP2Zz6UL4Lw4ArbLa1rZd" Name="SoilConductivity" Description="Thermal conductivity of soil. Generally, within standards such as IEC 60364-5-52, table 52A-16, the resistivity of soil is required (measured in [SI] units of degK.m /W). This is the reciprocal of the conductivity value and needs to be calculated accordingly." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermalConductivityMeasure" />
				<IfcSimplePropertyTemplate id="SolarAbsorption_24aeq0qTqHuO00025QrE$V" GlobalId="24aeq0qTqHuO00025QrE$V" Name="SolarAbsorption" Description="(Asol) The ratio of incident solar radiation that is absorbed by a glazing system. It is the sum of the absorption distributed to the exterior (a) and to the interior (qi). Note the following equation Asol + Rsol + Tsol = 1" TemplateType="p_singlevalue" PrimaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="SolarHeatGainTransmittance_2Hhtm0qTqHuO00025QrE$V" GlobalId="2Hhtm0qTqHuO00025QrE$V" Name="SolarHeatGainTransmittance" Description="(SHGC): The ratio of incident solar radiation that contributes to the heat gain of the interior, it is the solar radiation that directly passes (Tsol or τe) plus the part of the absorbed radiation that is distributed to the interior (qi). The SHGC is referred to also as g-value (g = τe + qi)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="SolarReflectance_25G1a0qWSHuO00025QrE$V" GlobalId="25G1a0qWSHuO00025QrE$V" Name="SolarReflectance" Description="(Rsol): The ratio of incident solar radiation that is reflected by a glazing system (also named ρe). Note the following equation Asol + Rsol + Tsol = 1" TemplateType="p_singlevalue" PrimaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="SolarReflectance_28lgg0qTqHuO00025QrE$V" GlobalId="28lgg0qTqHuO00025QrE$V" Name="SolarReflectance" Description="(Rsol): The ratio of incident solar radiation that is reflected by a glazing system (also named ρe). Note the following equation Asol + Rsol + Tsol = 1" TemplateType="p_singlevalue" PrimaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="SolarReflectanceBack_33C4E0qUqHuO00025QrE$V" GlobalId="33C4E0qUqHuO00025QrE$V" Name="SolarReflectanceBack" Description="Reflectance at normal incidence (solar): back side. Defines the fraction of the solar ray that is reflected and not transmitted when the ray passes from one medium into another, at the &quot;back&quot; side of the other material, perpendicular to the surface. Dependent on material and surface characteristics." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="SolarReflectanceFront_37zFU0qUqHuO00025QrE$V" GlobalId="37zFU0qUqHuO00025QrE$V" Name="SolarReflectanceFront" Description="Reflectance at normal incidence (solar): front side. Defines the fraction of the solar ray that is reflected and not transmitted when the ray passes from one medium into another, at the &quot;front&quot; side of the other material, perpendicular to the surface. Dependent on material and surface characteristics." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="SolarRefractionIndex_0lNdU0qUqHuO00025QrE$V" GlobalId="0lNdU0qUqHuO00025QrE$V" Name="SolarRefractionIndex" Description="Index of refraction (solar) defines the &quot;bending&quot; of the solar ray when it passes from one medium into another." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="SolarTransmittance_1vxEs0qWSHuO00025QrE$V" GlobalId="1vxEs0qWSHuO00025QrE$V" Name="SolarTransmittance" Description="The ratio of incident solar radiation that directly passes through a system (also named τe). Note the following equation Asol + Rsol + Tsol = 1" TemplateType="p_singlevalue" PrimaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="SolarTransmittance_2CwiW0qTqHuO00025QrE$V" GlobalId="2CwiW0qTqHuO00025QrE$V" Name="SolarTransmittance" Description="The ratio of incident solar radiation that directly passes through a system (also named τe). Note the following equation Asol + Rsol + Tsol = 1" TemplateType="p_singlevalue" PrimaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="SolarTransmittance_2SSWq0qUqHuO00025QrE$V" GlobalId="2SSWq0qUqHuO00025QrE$V" Name="SolarTransmittance" Description="The ratio of incident solar radiation that directly passes through a system (also named τe). Note the following equation Asol + Rsol + Tsol = 1" TemplateType="p_singlevalue" PrimaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="SolidCoreRecovery_00Xk2UDNv8yQeOebTR368_" GlobalId="00Xk2UDNv8yQeOebTR368_" Name="SolidCoreRecovery" Description="Length of solid core recovered expressed as a ratio of the length of core run." TemplateType="p_singlevalue" PrimaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="Sound_1bE3U0qRuHuO00025QrE$V" GlobalId="1bE3U0qRuHuO00025QrE$V" Name="Sound" Description="Sound performance." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcSoundPressureMeasure" />
				<IfcSimplePropertyTemplate id="SoundAbsorptionLimit_3Dyb6v_Lb0uePKj$y26Fb4" GlobalId="3Dyb6v_Lb0uePKj$y26Fb4" Name="SoundAbsorptionLimit" Description="Mandatory limit values in sound absorption." TemplateType="p_singlevalue" PrimaryMeasureType="IfcSoundPowerLevelMeasure" />
				<IfcSimplePropertyTemplate id="SoundCurve_2FhkA0qWWHuO00025QrE$V" GlobalId="2FhkA0qWWHuO00025QrE$V" Name="SoundCurve" Description="Sound curve.

Table of sound frequencies and sound power measured in decibels at a reference power of 1 picowatt(10\^(-12) watt) for the referenced octave band frequency." TemplateType="p_tablevalue" PrimaryMeasureType="IfcFrequencyMeasure" SecondaryMeasureType="IfcSoundPowerMeasure" />
				<IfcSimplePropertyTemplate id="SoundCurveHistory_2B5mc0qSaHuO00025QrE$V" GlobalId="2B5mc0qSaHuO00025QrE$V" Name="SoundCurveHistory" Description="Regenerated sound versus air-flow rate." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" />
				<IfcSimplePropertyTemplate id="SoundFrequency_20o300qWWHuO00025QrE$V" GlobalId="20o300qWWHuO00025QrE$V" Name="SoundFrequency" Description="List of nominal sound frequencies, correlated to the SoundPressure time series values (IfcTimeSeries.ListValues)" TemplateType="p_listvalue" PrimaryMeasureType="IfcFrequencyMeasure" />
				<IfcSimplePropertyTemplate id="SoundPressure_25ZEG0qWWHuO00025QrE$V" GlobalId="25ZEG0qWWHuO00025QrE$V" Name="SoundPressure" Description="A time series of sound pressure values measured in decibels at a reference pressure of 20 microPascals for the referenced octave band frequency. Each value in IfcTimeSeries.ListValues is correlated to the sound frequency at the same position within SoundFrequencies." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcSoundPressureMeasure" />
				<IfcSimplePropertyTemplate id="SoundPressureLevel_0w6C0kuKHCxwHMH3vR34Oa" GlobalId="0w6C0kuKHCxwHMH3vR34Oa" Name="SoundPressureLevel" Description="The sound pressure level measured at a specific location (e.g. 10m at 45 degrees)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcSoundPressureLevelMeasure" />
				<IfcSimplePropertyTemplate id="SoundScale_1qGzU0qWWHuO00025QrE$V" GlobalId="1qGzU0qWWHuO00025QrE$V" Name="SoundScale" Description="The reference sound scale.

DBA: Decibels in an A-weighted scale
DBB: Decibels in an B-weighted scale
DBC: Decibels in an C-weighted scale
NC: Noise criteria
NR: Noise rating" TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_SoundScale">
						<EnumerationValues>
							<IfcLabel-wrapper>DBA</IfcLabel-wrapper>
							<IfcLabel-wrapper>DBB</IfcLabel-wrapper>
							<IfcLabel-wrapper>DBC</IfcLabel-wrapper>
							<IfcLabel-wrapper>NC</IfcLabel-wrapper>
							<IfcLabel-wrapper>NR</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="SourceArea_1BMVyQRuL1zRS08BFGzp4P" GlobalId="1BMVyQRuL1zRS08BFGzp4P" Name="SourceArea" Description="Description of the area at the origin of the water inflow." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="SourceOfFill_1cA5Um37bAPRNMK84NGNf7" GlobalId="1cA5Um37bAPRNMK84NGNf7" Name="SourceOfFill" Description="Source of fill." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_SourceOfFill">
						<EnumerationValues>
							<IfcLabel-wrapper>IMPORTED</IfcLabel-wrapper>
							<IfcLabel-wrapper>EXCAVATED</IfcLabel-wrapper>
							<IfcLabel-wrapper>USERDEFINED</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="SourceOfFillOther_18ETTPAED9fwUL8dfinr7F" GlobalId="18ETTPAED9fwUL8dfinr7F" Name="SourceOfFillOther" Description="User defined Source of fill when SourceOfFill = USEDEFINED." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="SourceType_1wNA_lF8j57Ati7DZewGaj" GlobalId="1wNA_lF8j57Ati7DZewGaj" Name="SourceType" Description="Natural or artificial structure at the origin of the water inflow, like fracture, bedding, borehole, drainage pipe, drainage channel etc." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="SpaceAirTemperature_2c2Mu0qWaHuO00025QrE$V" GlobalId="2c2Mu0qWaHuO00025QrE$V" Name="SpaceAirTemperature" Description="Dry bulb temperature in the space." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="SpaceHeaterPlacement_3f$7C0qWaHuO00025QrE$V" GlobalId="3f$7C0qWaHuO00025QrE$V" Name="SpaceHeaterPlacement" Description="Indicates how the space heater is designed to be placed." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_SpaceHeaterPlacementType">
						<EnumerationValues>
							<IfcLabel-wrapper>BASEBOARD</IfcLabel-wrapper>
							<IfcLabel-wrapper>TOWELWARMER</IfcLabel-wrapper>
							<IfcLabel-wrapper>SUSPENDED</IfcLabel-wrapper>
							<IfcLabel-wrapper>WALL</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="SpaceHumidity_1hxPk0qWmHuO00025QrE$V" GlobalId="1hxPk0qWmHuO00025QrE$V" Name="SpaceHumidity" Description="Humidity of the space or zone that is required from user/designer view point.  If no summer or winter space humidity requirements are given, it applies all year, otherwise for the intermediate period. Provide this property, if no humidity range (Min-Max) is available." TemplateType="p_singlevalue" PrimaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="SpaceHumidityMax_1mia_0qWmHuO00025QrE$V" GlobalId="1mia_0qWmHuO00025QrE$V" Name="SpaceHumidityMax" Description="Maximal permitted humidity of the space or zone that is required from user/designer view point.  If no summer or winter space humidity requirements are given, it applies all year, otherwise for the intermediate period." TemplateType="p_singlevalue" PrimaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="SpaceHumidityMin_1sg320qWmHuO00025QrE$V" GlobalId="1sg320qWmHuO00025QrE$V" Name="SpaceHumidityMin" Description="Minimal permitted humidity of the space or zone that is required from user/designer view point.  If no summer or winter space humidity requirements are given, it applies all year, otherwise for the intermediate period." TemplateType="p_singlevalue" PrimaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="SpaceHumiditySummer_1y1Ni0qWmHuO00025QrE$V" GlobalId="1y1Ni0qWmHuO00025QrE$V" Name="SpaceHumiditySummer" Description="Humidity of the space or zone for the hot (summer) period, that is required from user/designer view point and provided as requirement for cooling." TemplateType="p_singlevalue" PrimaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="SpaceHumidityWinter_21OiM0qWmHuO00025QrE$V" GlobalId="21OiM0qWmHuO00025QrE$V" Name="SpaceHumidityWinter" Description="Humidity of the space or zone for the cold (winter) period that is required from user/designer view point and provided as requirement for heating." TemplateType="p_singlevalue" PrimaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="SpaceMeanRadiantTemperature_2fdFK0qWaHuO00025QrE$V" GlobalId="2fdFK0qWaHuO00025QrE$V" Name="SpaceMeanRadiantTemperature" Description="Mean radiant temperature in the space." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="SpaceRelativeHumidity_0ugmo0qWmHuO00025QrE$V" GlobalId="0ugmo0qWmHuO00025QrE$V" Name="SpaceRelativeHumidity" Description="The relative humidity of the space." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="SpaceTemperature_12pGi0qWmHuO00025QrE$V" GlobalId="12pGi0qWmHuO00025QrE$V" Name="SpaceTemperature" Description="Temperature of the space or zone, that is required from user/designer view point.  If no summer or winter space temperature requirements are given, it applies all year, otherwise for the intermediate period. Provide this value, if no temperatur range (Min-Max) is available." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="SpaceTemperatureHistory_0r5uM0qWmHuO00025QrE$V" GlobalId="0r5uM0qWmHuO00025QrE$V" Name="SpaceTemperatureHistory" Description="Temperature of the space." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="SpaceTemperatureMax_18mkm0qWmHuO00025QrE$V" GlobalId="18mkm0qWmHuO00025QrE$V" Name="SpaceTemperatureMax" Description="Maximal temperature of the space or zone, that is required from user/designer view point.  If no summer or winter space temperature requirements are given, it applies all year, otherwise for the intermediate period." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="SpaceTemperatureMin_1EkCq0qWmHuO00025QrE$V" GlobalId="1EkCq0qWmHuO00025QrE$V" Name="SpaceTemperatureMin" Description="Minimal temperature of the space or zone, that is required from user/designer view point. If no summer or winter space temperature requirements are given, it applies all year, otherwise for the intermediate period." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="SpaceTemperatureSummerMax_1K5XU0qWmHuO00025QrE$V" GlobalId="1K5XU0qWmHuO00025QrE$V" Name="SpaceTemperatureSummerMax" Description="Maximal temperature of the space or zone for the hot (summer) period, that is required from user/designer view point and provided as requirement for cooling." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="SpaceTemperatureSummerMin_1Q2$Y0qWmHuO00025QrE$V" GlobalId="1Q2$Y0qWmHuO00025QrE$V" Name="SpaceTemperatureSummerMin" Description="Minimal temperature of the space or zone for the hot (summer) period, that is required from user/designer view point and provided as requirement for cooling." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="SpaceTemperatureWinterMax_1W0Tc0qWmHuO00025QrE$V" GlobalId="1W0Tc0qWmHuO00025QrE$V" Name="SpaceTemperatureWinterMax" Description="Maximal temperature of the space or zone for the cold (winter) period, that is required from user/designer view point and provided as requirement for heating." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="SpaceTemperatureWinterMin_1bzxg0qWmHuO00025QrE$V" GlobalId="1bzxg0qWmHuO00025QrE$V" Name="SpaceTemperatureWinterMin" Description="Minimal temperature of the space or zone for the cold (winter) period, that is required from user/designer view point and provided as requirement for heating." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="Spacing_38x500qX8HuO00025QrE$V" GlobalId="38x500qX8HuO00025QrE$V" Name="Spacing" Description="Distance between fins on a tube in the tube bundle." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="SpacingBarPitch_3dIL00qW0HuO00025QrE$V" GlobalId="3dIL00qW0HuO00025QrE$V" Name="SpacingBarPitch" Description="The pitch length of the spacing bar." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="SpacingBarPitch_3PtvO0qVyHuO00025QrE$V" GlobalId="3PtvO0qVyHuO00025QrE$V" Name="SpacingBarPitch" Description="The pitch length of the spacing bar." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="Span_0PY8o0qSGHuO00025QrE$V" GlobalId="0PY8o0qSGHuO00025QrE$V" Name="Span" Description="Clear span for this object.The shape information is provided in addition to the shape representation and the geometric parameters used within. In cases of inconsistency between the geometric parameters and the shape properties, provided in the attached property, the geometric parameters take precedence. For geometry editing applications, like CAD: this value should be write-only." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="Span_1Ttb60qV4HuO00025QrE$V" GlobalId="1Ttb60qV4HuO00025QrE$V" Name="Span" Description="Clear span for this object.The shape information is provided in addition to the shape representation and the geometric parameters used within. In cases of inconsistency between the geometric parameters and the shape properties, provided in the attached property, the geometric parameters take precedence. For geometry editing applications, like CAD: this value should be write-only." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="SpanNominalLength_0oTEbvO096Gv87GKVYXQSy" GlobalId="0oTEbvO096Gv87GKVYXQSy" Name="SpanNominalLength" Description="The length of span as a design parameter for the overhead contactline system." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="SparkGapType_2yd82GST551f428rzb7p5q" GlobalId="2yd82GST551f428rzb7p5q" Name="SparkGapType" Description="Type of Spark gap." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_SparkGapType">
						<EnumerationValues>
							<IfcLabel-wrapper>AIRSPARKGAP</IfcLabel-wrapper>
							<IfcLabel-wrapper>GASFILLEDSPARKGAP</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="SpeakerDriverSize_2uOBa0qSCHuO00025QrE$V" GlobalId="2uOBa0qSCHuO00025QrE$V" Name="SpeakerDriverSize" Description="Indicates the number of drivers and their sizes." TemplateType="p_tablevalue" PrimaryMeasureType="IfcIdentifier" SecondaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="SpeakerMounting_2d5wo0qSCHuO00025QrE$V" GlobalId="2d5wo0qSCHuO00025QrE$V" Name="SpeakerMounting" Description="Indicates how the speaker is designed to be mounted." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_AudioVisualSpeakerMounting">
						<EnumerationValues>
							<IfcLabel-wrapper>FREESTANDING</IfcLabel-wrapper>
							<IfcLabel-wrapper>CEILING</IfcLabel-wrapper>
							<IfcLabel-wrapper>WALL</IfcLabel-wrapper>
							<IfcLabel-wrapper>OUTDOOR</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="SpeakerType_2KdNC0qSCHuO00025QrE$V" GlobalId="2KdNC0qSCHuO00025QrE$V" Name="SpeakerType" Description="Indicates the type of speaker." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_AudioVisualSpeakerType">
						<EnumerationValues>
							<IfcLabel-wrapper>FULLRANGE</IfcLabel-wrapper>
							<IfcLabel-wrapper>MIDRANGE</IfcLabel-wrapper>
							<IfcLabel-wrapper>WOOFER</IfcLabel-wrapper>
							<IfcLabel-wrapper>TWEETER</IfcLabel-wrapper>
							<IfcLabel-wrapper>COAXIAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="SpecialConstruction_27WeC0qSSHuO00025QrE$V" GlobalId="27WeC0qSSHuO00025QrE$V" Name="SpecialConstruction" Description="Special construction capabilities like self-supporting, flat devidable cable or bus flat non devidable cable or bus supporting elements inside (steal, textile, concentric conductor). Note that materials used should be agreed between exchange participants before use." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="SpecialInstructions_1H3Ys0qV8HuO00025QrE$V" GlobalId="1H3Ys0qV8HuO00025QrE$V" Name="SpecialInstructions" Description="Special instructions." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="SpecialInstructions_3FkPc0qVSHuO00025QrE$V" GlobalId="3FkPc0qVSHuO00025QrE$V" Name="SpecialInstructions" Description="Special instructions." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="SpecialPositionArrangement_1eejWaX7j3auMW_oHyVPWg" GlobalId="1eejWaX7j3auMW_oHyVPWg" Name="SpecialPositionArrangement" Description="Type of special position at which the signal is placed." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="SpecialRequirements_1kGlm0qV8HuO00025QrE$V" GlobalId="1kGlm0qV8HuO00025QrE$V" Name="SpecialRequirements" Description="Any additional special requirements that need to be included in the permit to work.

NOTE - Additional permit requirements may be imposed according to the nature of the facility at which the work is carried out. For instance, in clean areas, special clothing may be required whilst in corrective institutions, it may be necessary to check in and check out tools that will be used for work as a safety precaution." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="Species_19J8e0qUuHuO00025QrE$V" GlobalId="19J8e0qUuHuO00025QrE$V" Name="Species" Description="Wood species of a solid wood or laminated wood product." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="SpecificationSectionNumber_0$GZsDpVX0HeG5RURnigAw" GlobalId="0$GZsDpVX0HeG5RURnigAw" Name="SpecificationSectionNumber" Description="A reference number to an external contract technical specification section describing either (a) minimum performance requirements of a given IfcProductType/IfcProduct or (b) a preselection for a specific IfcProductType/IfcProduct made for this project." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="SpecificHeatCapacity_078qY0qUuHuO00025QrE$V" GlobalId="078qY0qUuHuO00025QrE$V" Name="SpecificHeatCapacity" Description="Defines the specific heat capacity of a material.

Defines the specific heat of the material: heat energy absorbed per temperature unit." TemplateType="p_singlevalue" PrimaryMeasureType="IfcSpecificHeatCapacityMeasure" />
				<IfcSimplePropertyTemplate id="SpecificHeatCapacity_2szxQ0qUmHuO00025QrE$V" GlobalId="2szxQ0qUmHuO00025QrE$V" Name="SpecificHeatCapacity" Description="Defines the specific heat capacity of a material.

Specific heat of the products of combustion: heat energy absorbed per temperature unit." TemplateType="p_singlevalue" PrimaryMeasureType="IfcSpecificHeatCapacityMeasure" />
				<IfcSimplePropertyTemplate id="SpecificHeatTemperatureDerivative_0YsXy0qUqHuO00025QrE$V" GlobalId="0YsXy0qUqHuO00025QrE$V" Name="SpecificHeatTemperatureDerivative" Description="Specific heat temperature derivative." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="Spectrum_1BOHc0qUiHuO00025QrE$V" GlobalId="1BOHc0qUiHuO00025QrE$V" Name="Spectrum" Description="The spectrum of radiation describes its composition with regard to wavelength. Light, for example, as the portion of electromagnetic radiation that is visible to the human eye, is radiation with wavelengths in the range of approx. 380 to 780 nm (1 nm = 10 m). The corresponding range of colours varies from violet to indigo, blue, green, yellow, orange, and red. These colours form a continuous spectrum, in which the various spectral sectors merge into each other." TemplateType="p_tablevalue" PrimaryMeasureType="IfcNumericMeasure" SecondaryMeasureType="IfcNumericMeasure" />
				<IfcSimplePropertyTemplate id="SpilloverLevel_0FXdu0qWGHuO00025QrE$V" GlobalId="0FXdu0qWGHuO00025QrE$V" Name="SpilloverLevel" Description="The level at which water spills out of the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="SpilloverLevel_1JU8E0qW8HuO00025QrE$V" GlobalId="1JU8E0qW8HuO00025QrE$V" Name="SpilloverLevel" Description="The level at which water spills out of the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="SpilloverLevel_1PRsG0qWGHuO00025QrE$V" GlobalId="1PRsG0qWGHuO00025QrE$V" Name="SpilloverLevel" Description="The level at which water spills out of the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="SpilloverLevel_1yemy0qXOHuO00025QrE$V" GlobalId="1yemy0qXOHuO00025QrE$V" Name="SpilloverLevel" Description="The level at which water spills out of the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="SpontaneousPotential_0QWHw4BW90SxlAkUg4JefW" GlobalId="0QWHw4BW90SxlAkUg4JefW" Name="SpontaneousPotential" Description="Naturally occurring (static) electrical potential in the Earth. Spontaneous potentials (SP) are usually caused by charge separation in clay or other minerals, by the presence of a semipermeable interface impeding the diffusion of ions through the pore space of rocks, or by natural flow of a conducting fluid (salty water) through the rocks. Variations in SP can be measured in the field and in wellbores to determine variations of ionic concentration in pore fluids of rocks." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricVoltageMeasure" />
				<IfcSimplePropertyTemplate id="SprayType_2Lr9q0qSyHuO00025QrE$V" GlobalId="2Lr9q0qSyHuO00025QrE$V" Name="SprayType" Description="SprayFilled: Water is sprayed into airflow.
SplashTypeFill: water cascades over successive rows of splash bars.
FilmTypeFill: water flows in a thin layer over closely spaced sheets." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_CoolingTowerSprayType">
						<EnumerationValues>
							<IfcLabel-wrapper>SPRAYFILLED</IfcLabel-wrapper>
							<IfcLabel-wrapper>SPLASHTYPEFILL</IfcLabel-wrapper>
							<IfcLabel-wrapper>FILMTYPEFILL</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="SpreadingRate_3zsj40KP9DfPZBUt5MVyt5" GlobalId="3zsj40KP9DfPZBUt5MVyt5" Name="SpreadingRate" Description="The nominal overall mass of material per area covered by the course." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNumericMeasure" />
				<IfcSimplePropertyTemplate id="SprinklerProtection_07Mnu0qSKHuO00025QrE$V" GlobalId="07Mnu0qSKHuO00025QrE$V" Name="SprinklerProtection" Description="Indication whether this object is sprinkler protected (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="SprinklerProtection_1_6Wg0qWaHuO00025QrE$V" GlobalId="1_6Wg0qWaHuO00025QrE$V" Name="SprinklerProtection" Description="Indication whether this object is sprinkler protected (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="SprinklerProtection_2GSbK0qSKHuO00025QrE$V" GlobalId="2GSbK0qSKHuO00025QrE$V" Name="SprinklerProtection" Description="Indication whether this object is sprinkler protected (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="SprinklerProtectionAutomatic_0C7z80qSKHuO00025QrE$V" GlobalId="0C7z80qSKHuO00025QrE$V" Name="SprinklerProtectionAutomatic" Description="Indication whether this object has an automatic sprinkler protection (TRUE) or not (FALSE).
It should only be given, if the property &quot;SprinklerProtection&quot; is set to TRUE." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="SprinklerProtectionAutomatic_243_k0qWaHuO00025QrE$V" GlobalId="243_k0qWaHuO00025QrE$V" Name="SprinklerProtectionAutomatic" Description="Indication whether this object has an automatic sprinkler protection (TRUE) or not (FALSE).
It should only be given, if the property &quot;SprinklerProtection&quot; is set to TRUE." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="SprinklerType_0TUTO0qUSHuO00025QrE$V" GlobalId="0TUTO0qUSHuO00025QrE$V" Name="SprinklerType" Description="Identifies the predefined types of sprinkler from which the type required may be set." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_SprinklerType">
						<EnumerationValues>
							<IfcLabel-wrapper>CEILING</IfcLabel-wrapper>
							<IfcLabel-wrapper>CONCEALED</IfcLabel-wrapper>
							<IfcLabel-wrapper>CUTOFF</IfcLabel-wrapper>
							<IfcLabel-wrapper>PENDANT</IfcLabel-wrapper>
							<IfcLabel-wrapper>RECESSEDPENDANT</IfcLabel-wrapper>
							<IfcLabel-wrapper>SIDEWALL</IfcLabel-wrapper>
							<IfcLabel-wrapper>UPRIGHT</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="SPTBlowCount_35XQNkKeH4W8XkaRfglEJO" GlobalId="35XQNkKeH4W8XkaRfglEJO" Name="SPTBlowCount" Description="Number of blows required to drive the sampler for a test drive of 300 mm following the seating drive." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="Staggered_0eCsk0qUKHuO00025QrE$V" GlobalId="0eCsk0qUKHuO00025QrE$V" Name="Staggered" Description="If intermittent weld, staggered or not" TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="StaggeredRowSpacing_1Uqwi0qX8HuO00025QrE$V" GlobalId="1Uqwi0qX8HuO00025QrE$V" Name="StaggeredRowSpacing" Description="Staggered tube row spacing." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="Standard_0h7sE0qSSHuO00025QrE$V" GlobalId="0h7sE0qSSHuO00025QrE$V" Name="Standard" Description="The designation of the standard applicable for the definition of the object used." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="Standard_0V0Sa0qVmHuO00025QrE$V" GlobalId="0V0Sa0qVmHuO00025QrE$V" Name="Standard" Description="The designation of the standard applicable for the definition of the object used.

The designation of the standard applicable for the definition of the characteristics of the
tripping_unit." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="StandardFixingPlateDepth_3kyW00qT8HuO00025QrE$V" GlobalId="3kyW00qT8HuO00025QrE$V" Name="StandardFixingPlateDepth" Description="The depth of the standard fixing plate." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="StandardFixingPlateThickness_3qJqg0qT8HuO00025QrE$V" GlobalId="3qJqg0qT8HuO00025QrE$V" Name="StandardFixingPlateThickness" Description="The thickness of the standard fixing plate." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="StandardFixingPlateWidth_3e$1y0qT8HuO00025QrE$V" GlobalId="3e$1y0qT8HuO00025QrE$V" Name="StandardFixingPlateWidth" Description="The width of the standard fixing plate." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="StartCurrentFactor_30Uo60qU0HuO00025QrE$V" GlobalId="30Uo60qU0HuO00025QrE$V" Name="StartCurrentFactor" Description="IEC. Start current factor defines how large the peak starting current will become on the engine. StartCurrentFactor is multiplied to NominalCurrent and to give the start current." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="StartCurrentFactor_3k_Fo0qU0HuO00025QrE$V" GlobalId="3k_Fo0qU0HuO00025QrE$V" Name="StartCurrentFactor" Description="IEC. Start current factor defines how large the peak starting current will become on the engine. StartCurrentFactor is multiplied to NominalCurrent and to give the start current." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="StartDate_1ZY6S0qV8HuO00025QrE$V" GlobalId="1ZY6S0qV8HuO00025QrE$V" Name="StartDate" Description="Date and time from which the permit becomes valid." TemplateType="p_singlevalue" PrimaryMeasureType="IfcDateTime" />
				<IfcSimplePropertyTemplate id="StartElevation_0KcYsFKoPBSh0Sikz0RXzV" GlobalId="0KcYsFKoPBSh0Sikz0RXzV" Name="StartElevation" Description="Elevation of the start point relative to the mean sea level." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="StarterType_2Pqz_0qWuHuO00025QrE$V" GlobalId="2Pqz_0qWuHuO00025QrE$V" Name="StarterType" Description="A list of the available types of starter from which that required may be selected where:

AutoTransformer: A starter for an induction motor which uses for starting one or more reduced voltages derived from an auto transformer. (IEC 441-14-45)
Manual: A starter in which the force for closing the main contacts is provided exclusively by manual energy. (IEC 441-14-39)
DirectOnLine: A starter which connects the line voltage across the motor terminals in one step. (IEC 441-14-40)
Frequency: A starter in which the frequency of the power supply is progressively increased until the normal operation frequency is attained.
nStep: A starter in which there are (n-1) intermediate accelerating positions between the off and full on positions. (IEC 441-14-41)
Rheostatic: A starter using one or several resistors for obtaining, during starting, stated motor torque characteristics and for limiting the current. (IEC 441-14-425)
StarDelta: A starter for a 3 phase induction motor such that in the starting position the stator windings are connected in star and in the final running position they are connected in delta. (IEC 441-14-44)" TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_StarterType">
						<EnumerationValues>
							<IfcLabel-wrapper>AUTOTRANSFORMER</IfcLabel-wrapper>
							<IfcLabel-wrapper>MANUAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>DIRECTONLINE</IfcLabel-wrapper>
							<IfcLabel-wrapper>FREQUENCY</IfcLabel-wrapper>
							<IfcLabel-wrapper>NSTEP</IfcLabel-wrapper>
							<IfcLabel-wrapper>RHEOSTATIC</IfcLabel-wrapper>
							<IfcLabel-wrapper>STARDELTA</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="StartingTime_3p9He0qU0HuO00025QrE$V" GlobalId="3p9He0qU0HuO00025QrE$V" Name="StartingTime" Description="The time (in s) needed for the motor to reach its rated speed with its driven equipment attached, starting from standstill and at the nominal voltage applied at its terminals." TemplateType="p_singlevalue" PrimaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="StartingWindSpeed_1WVoOImSPC5vxwgP5hvg3Y" GlobalId="1WVoOImSPC5vxwgP5hvg3Y" Name="StartingWindSpeed" Description="Indicates the starting wind speed of the wind sensor." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLinearVelocityMeasure" />
				<IfcSimplePropertyTemplate id="StartSmoothingLength_01PipsVZr9Q8Qgw9_KMfFV" GlobalId="01PipsVZr9Q8Qgw9_KMfFV" Name="StartSmoothingLength" Description="Length for the circular transition change of curvature at the start of the cant segment, measured from the start of the cant segment to the end of the circular transition change of curvature." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="StaticDischargeHead_0BrAnLHer7kPgv2nOUi7ob" GlobalId="0BrAnLHer7kPgv2nOUi7ob" Name="StaticDischargeHead" Description="Measurement of the vertical distance from the discharge point to a reference elevation." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="StaticLoad_35jL348fLEw8Qtk01HBCmU" GlobalId="35jL348fLEw8Qtk01HBCmU" Name="StaticLoad" Description="The static load on the shell construction when the fan is in operation." TemplateType="p_singlevalue" PrimaryMeasureType="IfcForceMeasure" />
				<IfcSimplePropertyTemplate id="StaticSuctionLift_1nUwk$OBT5O9pgD19FbFDm" GlobalId="1nUwk$OBT5O9pgD19FbFDm" Name="StaticSuctionLift" Description="Measurement of the vertical distance between the water table and the suction point." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="Station_2wUFXsqVDB8fwdTk7zGJXN" GlobalId="2wUFXsqVDB8fwdTk7zGJXN" Name="Station" Description="The station value at this location." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="Status_002JG0qWWHuO00025QrE$V" GlobalId="002JG0qWWHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_05abe0qSSHuO00025QrE$V" GlobalId="05abe0qSSHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_05g4y0qVCHuO00025QrE$V" GlobalId="05g4y0qVCHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_08y0g0qVGHuO00025QrE$V" GlobalId="08y0g0qVGHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_09SAq0qSGHuO00025QrE$V" GlobalId="09SAq0qSGHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_09VQQ0qTuHuO00025QrE$V" GlobalId="09VQQ0qTuHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_0CBig0qUCHuO00025QrE$V" GlobalId="0CBig0qUCHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_0CKeiSTML5V8Nk6QNncdRn" GlobalId="0CKeiSTML5V8Nk6QNncdRn" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_0D5Yi0qUWHuO00025QrE$V" GlobalId="0D5Yi0qUWHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_0DRV20qVyHuO00025QrE$V" GlobalId="0DRV20qVyHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_0EKLC0qVmHuO00025QrE$V" GlobalId="0EKLC0qVmHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_0EW2q0qS4HuO00025QrE$V" GlobalId="0EW2q0qS4HuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_0F7i20qSqHuO00025QrE$V" GlobalId="0F7i20qSqHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure).

Indicates an error code or identifier, whose meaning is specific to the particular automation system.  Example values include: &apos;ConfigurationError&apos;, &apos;NotConnected&apos;, &apos;DeviceFailure&apos;, &apos;SensorFailure&apos;, &apos;LastKnown, &apos;CommunicationsFailure&apos;, &apos;OutOfService&apos;." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="Status_0g52E0qXCHuO00025QrE$V" GlobalId="0g52E0qXCHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_0GE0ZFN_PDM9vp5yT9CKUr" GlobalId="0GE0ZFN_PDM9vp5yT9CKUr" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_0hnFE0qU4HuO00025QrE$V" GlobalId="0hnFE0qU4HuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_0jDFA0qSOHuO00025QrE$V" GlobalId="0jDFA0qSOHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_0l_Gq0qV4HuO00025QrE$V" GlobalId="0l_Gq0qV4HuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_0L4w80qSiHuO00025QrE$V" GlobalId="0L4w80qSiHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_0ND2k0qU0HuO00025QrE$V" GlobalId="0ND2k0qU0HuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_0o2vs0qUeHuO00025QrE$V" GlobalId="0o2vs0qUeHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_0owGC0qTiHuO00025QrE$V" GlobalId="0owGC0qTiHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_0Q9o00qT0HuO00025QrE$V" GlobalId="0Q9o00qT0HuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_0Qc9xk12n40eCxiaK_E2E8" GlobalId="0Qc9xk12n40eCxiaK_E2E8" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_0R776yD1b15fWhkijME2BM" GlobalId="0R776yD1b15fWhkijME2BM" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_0SEw_0qSqHuO00025QrE$V" GlobalId="0SEw_0qSqHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_0uyDi0qVyHuO00025QrE$V" GlobalId="0uyDi0qVyHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_0w1HQ0qSKHuO00025QrE$V" GlobalId="0w1HQ0qSKHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_0Wvqzvq7L0UfBvFMU8A1Co" GlobalId="0Wvqzvq7L0UfBvFMU8A1Co" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_107kM0qWqHuO00025QrE$V" GlobalId="107kM0qWqHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_10ebfaOlX82fn9pBND2gTI" GlobalId="10ebfaOlX82fn9pBND2gTI" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_11wQ4bRUr9fho1muno$GPl" GlobalId="11wQ4bRUr9fho1muno$GPl" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished, &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_12qWY0qXOHuO00025QrE$V" GlobalId="12qWY0qXOHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_16Ysu0qSaHuO00025QrE$V" GlobalId="16Ysu0qSaHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_18nUg0qX8HuO00025QrE$V" GlobalId="18nUg0qX8HuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_1B4L00qUGHuO00025QrE$V" GlobalId="1B4L00qUGHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_1BT100qX4HuO00025QrE$V" GlobalId="1BT100qX4HuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_1clYk0qSyHuO00025QrE$V" GlobalId="1clYk0qSyHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_1ephq0qSGHuO00025QrE$V" GlobalId="1ephq0qSGHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_1EQWC0qWSHuO00025QrE$V" GlobalId="1EQWC0qWSHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_1Fa3M0qV4HuO00025QrE$V" GlobalId="1Fa3M0qV4HuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_1FY3c0qU4HuO00025QrE$V" GlobalId="1FY3c0qU4HuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_1hrgS0qTuHuO00025QrE$V" GlobalId="1hrgS0qTuHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_1My8v0zEn4Hek5k3AKjbvV" GlobalId="1My8v0zEn4Hek5k3AKjbvV" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_1OXmG0qVqHuO00025QrE$V" GlobalId="1OXmG0qVqHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_1pD6GEhpb3kQoohaFgDAHz" GlobalId="1pD6GEhpb3kQoohaFgDAHz" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_1QWv_0qSeHuO00025QrE$V" GlobalId="1QWv_0qSeHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_1Rqxq0qWWHuO00025QrE$V" GlobalId="1Rqxq0qWWHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_1sapi0qU8HuO00025QrE$V" GlobalId="1sapi0qU8HuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_1Sb340qRyHuO00025QrE$V" GlobalId="1Sb340qRyHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_1ujyA0qVyHuO00025QrE$V" GlobalId="1ujyA0qVyHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_1uNls0qUOHuO00025QrE$V" GlobalId="1uNls0qUOHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_1UP__0qTCHuO00025QrE$V" GlobalId="1UP__0qTCHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_1V2u20qUaHuO00025QrE$V" GlobalId="1V2u20qUaHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_1Xfg_0qS8HuO00025QrE$V" GlobalId="1Xfg_0qS8HuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_1XgAw0qSOHuO00025QrE$V" GlobalId="1XgAw0qSOHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_1xvue0qT0HuO00025QrE$V" GlobalId="1xvue0qT0HuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_1z3xk0qRuHuO00025QrE$V" GlobalId="1z3xk0qRuHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_23_lO0qTyHuO00025QrE$V" GlobalId="23_lO0qTyHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_2caGq0qUSHuO00025QrE$V" GlobalId="2caGq0qUSHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_2DrYQ0qUeHuO00025QrE$V" GlobalId="2DrYQ0qUeHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_2f1bs0qWqHuO00025QrE$V" GlobalId="2f1bs0qWqHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_2fCvAGBpr3x8S7N8rZtpnP" GlobalId="2fCvAGBpr3x8S7N8rZtpnP" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_2IwgG0qV4HuO00025QrE$V" GlobalId="2IwgG0qV4HuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_2iwwq0qXWHuO00025QrE$V" GlobalId="2iwwq0qXWHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_2j9880qV4HuO00025QrE$V" GlobalId="2j9880qV4HuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_2jQ560qU0HuO00025QrE$V" GlobalId="2jQ560qU0HuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_2jqPnPi7zFNRX$OEExuOpW" GlobalId="2jqPnPi7zFNRX$OEExuOpW" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_2LIV_0qUiHuO00025QrE$V" GlobalId="2LIV_0qUiHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_2mMaQ0qSuHuO00025QrE$V" GlobalId="2mMaQ0qSuHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_2moW00qXKHuO00025QrE$V" GlobalId="2moW00qXKHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_2Ngbg0qUSHuO00025QrE$V" GlobalId="2Ngbg0qUSHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure).

Indicates an error code or identifier, whose meaning is specific to the particular automation system.  Example values include: &apos;ConfigurationError&apos;, &apos;NotConnected&apos;, &apos;DeviceFailure&apos;, &apos;SensorFailure&apos;, &apos;LastKnown, &apos;CommunicationsFailure&apos;, &apos;OutOfService&apos;." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="Status_2Ni5U0qVCHuO00025QrE$V" GlobalId="2Ni5U0qVCHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_2OUyO0qS0HuO00025QrE$V" GlobalId="2OUyO0qS0HuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_2qpp40qSSHuO00025QrE$V" GlobalId="2qpp40qSSHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_2uEDk0qWmHuO00025QrE$V" GlobalId="2uEDk0qWmHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_2UHSk0qW4HuO00025QrE$V" GlobalId="2UHSk0qW4HuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_2Umd00qSaHuO00025QrE$V" GlobalId="2Umd00qSaHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_2v34O0qUaHuO00025QrE$V" GlobalId="2v34O0qUaHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_2Vfz60qSeHuO00025QrE$V" GlobalId="2Vfz60qSeHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_2xRA40qUKHuO00025QrE$V" GlobalId="2xRA40qUKHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_31drK0qSOHuO00025QrE$V" GlobalId="31drK0qSOHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_35evK0qWyHuO00025QrE$V" GlobalId="35evK0qWyHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_36V$i0qVuHuO00025QrE$V" GlobalId="36V$i0qVuHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_3I9Ey0qWaHuO00025QrE$V" GlobalId="3I9Ey0qWaHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_3iucu0qTyHuO00025QrE$V" GlobalId="3iucu0qTyHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_3lXPa0qSWHuO00025QrE$V" GlobalId="3lXPa0qSWHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_3lzb80qX4HuO00025QrE$V" GlobalId="3lzb80qX4HuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_3mF220qWGHuO00025QrE$V" GlobalId="3mF220qWGHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_3N8NY0qU0HuO00025QrE$V" GlobalId="3N8NY0qU0HuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_3P0J40qWmHuO00025QrE$V" GlobalId="3P0J40qWmHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_3PG0C0qV4HuO00025QrE$V" GlobalId="3PG0C0qV4HuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_3PKFg0qXCHuO00025QrE$V" GlobalId="3PKFg0qXCHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_3T5be0qTuHuO00025QrE$V" GlobalId="3T5be0qTuHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_3Xr160qT0HuO00025QrE$V" GlobalId="3Xr160qT0HuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Status_3zvAo0qUeHuO00025QrE$V" GlobalId="3zvAo0qUeHuO00025QrE$V" Name="Status" Description="Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as &quot;New&quot; - element designed as new addition, &quot;Existing&quot; - element exists and remains, &quot;Demolish&quot; - element existed but is to be demolished,  &quot;Temporary&quot; - element will exists only temporary (like a temporary support structure)." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i58" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="StatusHistory_1aJo7SF6zDiuWBtuk6BCna" GlobalId="1aJo7SF6zDiuWBtuk6BCna" Name="StatusHistory" Description="Indicates an error code or identifier, whose meaning is specific to the particular automation system.  Example values include: &apos;ConfigurationError&apos;, &apos;NotConnected&apos;, &apos;DeviceFailure&apos;, &apos;SensorFailure&apos;, &apos;LastKnown, &apos;CommunicationsFailure&apos;, &apos;OutOfService&apos;." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="SteadyDeviceType_1vPh$B_I5FigMapMG3Ne8f" GlobalId="1vPh$B_I5FigMapMG3Ne8f" Name="SteadyDeviceType" Description="Type of Steady Device: To indicate the mode of registration." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_SteadyDeviceType">
						<EnumerationValues>
							<IfcLabel-wrapper>PULL_OFF</IfcLabel-wrapper>
							<IfcLabel-wrapper>PUSH_OFF</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Steam_3wiUQ0qXCHuO00025QrE$V" GlobalId="3wiUQ0qXCHuO00025QrE$V" Name="Steam" Description="The amount of steam consumed during the period specified in the time series." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcMassMeasure" />
				<IfcSimplePropertyTemplate id="StemBaseChamfer_2mkWW0qVKHuO00025QrE$V" GlobalId="2mkWW0qVKHuO00025QrE$V" Name="StemBaseChamfer" Description="Stem base chamfer of the profile." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNonNegativeLengthMeasure" />
				<IfcSimplePropertyTemplate id="StemBaseFillet_2y3JE0qVKHuO00025QrE$V" GlobalId="2y3JE0qVKHuO00025QrE$V" Name="StemBaseFillet" Description="Stem base fillet of the profile." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNonNegativeLengthMeasure" />
				<IfcSimplePropertyTemplate id="StemBaseWidth_2ZdHa0qVKHuO00025QrE$V" GlobalId="2ZdHa0qVKHuO00025QrE$V" Name="StemBaseWidth" Description="Stem base width of the profile." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="StemTopChamfer_2s5rA0qVKHuO00025QrE$V" GlobalId="2s5rA0qVKHuO00025QrE$V" Name="StemTopChamfer" Description="Stem top chamfer of the profile." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNonNegativeLengthMeasure" />
				<IfcSimplePropertyTemplate id="StemTopFillet_30qUU0qVKHuO00025QrE$V" GlobalId="30qUU0qVKHuO00025QrE$V" Name="StemTopFillet" Description="Stem top fillet of the profile." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNonNegativeLengthMeasure" />
				<IfcSimplePropertyTemplate id="StemTopWidth_2gAv20qVKHuO00025QrE$V" GlobalId="2gAv20qVKHuO00025QrE$V" Name="StemTopWidth" Description="Stem top width of the profile." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="StirrupBarPitch_3JKHw0qVyHuO00025QrE$V" GlobalId="3JKHw0qVyHuO00025QrE$V" Name="StirrupBarPitch" Description="The pitch length of the stirrup bar." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="StockRailRadius_1GaLKhaGH1$x4YploezUeu" GlobalId="1GaLKhaGH1$x4YploezUeu" Name="StockRailRadius" Description="The radius of the stock rail bend defined as design parameter." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="StoneFinishes_0D2MZl1bLBAhq4V$nrIFaO" GlobalId="0D2MZl1bLBAhq4V$nrIFaO" Name="StoneFinishes" Description="Eg. &apos;Polished&apos;, &apos;Bush Hammered&apos;, &apos;Split&apos;, &apos;Sawn&apos;, &apos;Flamed&apos;" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="StopCriteria_0VnR5KKK1AMxLKKTmKRldq" GlobalId="0VnR5KKK1AMxLKKTmKRldq" Name="StopCriteria" Description="Description of the stop criteria." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="StorageCapacity_1$iZi7fOT5d8x0ECyuS0B0" GlobalId="1$iZi7fOT5d8x0ECyuS0B0" Name="StorageCapacity" Description="Indicates the total data storage capacity of the device. It is defined by bytes." TemplateType="p_singlevalue" PrimaryMeasureType="IfcInteger" />
				<IfcSimplePropertyTemplate id="StorageCapacity_1l1lxKbmn2bAy1hWV7EsM1" GlobalId="1l1lxKbmn2bAy1hWV7EsM1" Name="StorageCapacity" Description="Indicates the total data storage capacity of the device. It is defined by bytes." TemplateType="p_singlevalue" PrimaryMeasureType="IfcInteger" />
				<IfcSimplePropertyTemplate id="StorageCoefficient_36wybY1$X62RvbVDalUFnE" GlobalId="36wybY1$X62RvbVDalUFnE" Name="StorageCoefficient" Description="Ratio of the volume of water released or stored per unit area of an aquifer, to the corresponding charge in hydraulic head, without reference to time." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="StorageTemperatureRange_0T6ELr2bv1MP48HEd_Ue3i" GlobalId="0T6ELr2bv1MP48HEd_Ue3i" Name="StorageTemperatureRange" Description="Allowed storage temperature range that the element complies with." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="StorageType_3WTWc0qWyHuO00025QrE$V" GlobalId="3WTWc0qWyHuO00025QrE$V" Name="StorageType" Description="Defines the general material category intended to be stored." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_TankStorageType">
						<EnumerationValues>
							<IfcLabel-wrapper>ICE</IfcLabel-wrapper>
							<IfcLabel-wrapper>WATER</IfcLabel-wrapper>
							<IfcLabel-wrapper>RAINWATER</IfcLabel-wrapper>
							<IfcLabel-wrapper>WASTEWATER</IfcLabel-wrapper>
							<IfcLabel-wrapper>POTABLEWATER</IfcLabel-wrapper>
							<IfcLabel-wrapper>FUEL</IfcLabel-wrapper>
							<IfcLabel-wrapper>OIL</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Storativity_3r4XeQVXvA6AD_i9IARgJN" GlobalId="3r4XeQVXvA6AD_i9IARgJN" Name="Storativity" Description="Volume of water released from storage per unit surface area of a confined aquifer per unit decline in hydraulic head. It is dimensionless." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="StrandingMethod_3LKqUANgv49RHlqIkKEDH9" GlobalId="3LKqUANgv49RHlqIkKEDH9" Name="StrandingMethod" Description="Specifies the method used to strand the cable. Stranding is the process where a particular number of stranding elements are joined together while winding them round a common axis." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="StratosphericOzoneLayerDestruction_10xb80qU8HuO00025QrE$V" GlobalId="10xb80qU8HuO00025QrE$V" Name="StratosphericOzoneLayerDestruction" Description="Quantity of gases destroying the stratospheric ozone layer calculated in equivalent CFC-R11." TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassMeasure" />
				<IfcSimplePropertyTemplate id="StratosphericOzoneLayerDestructionPerUnit_3iIjS0qU4HuO00025QrE$V" GlobalId="3iIjS0qU4HuO00025QrE$V" Name="StratosphericOzoneLayerDestructionPerUnit" Description="Quantity of gases destroying the stratospheric ozone layer calculated in equivalent CFC-R11" TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassMeasure" />
				<IfcSimplePropertyTemplate id="StratumColour_0iHTZHO0b8BO33foHizEN0" GlobalId="0iHTZHO0b8BO33foHizEN0" Name="StratumColour" Description="Stratum colour" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="StrengthClass_2MEGt4G$r1s8oshAXjpacJ" GlobalId="2MEGt4G$r1s8oshAXjpacJ" Name="StrengthClass" Description="Classification of the concrete strength in accordance with the concrete design code which is applied in the project." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="StrengthGrade_1EgTI0qUuHuO00025QrE$V" GlobalId="1EgTI0qUuHuO00025QrE$V" Name="StrengthGrade" Description="Grade with respect to mechanical strength and stiffness." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="StrikeDirection_2OgLQou3zDDO0kYsfjEdze" GlobalId="2OgLQou3zDDO0kYsfjEdze" Name="StrikeDirection" Description="The geographic direction of a line created by the intersection of a plane and the horizontal plane. If non specific convention is used, this angular value is in the range 0 to 180 degrees. A strike value is generally completed with an indication of the dip direction." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="Stroke_2Csj00qRqHuO00025QrE$V" GlobalId="2Csj00qRqHuO00025QrE$V" Name="Stroke" Description="Indicates the maximum distance the actuator must traverse." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="StructuralClass_24YP60qSiHuO00025QrE$V" GlobalId="24YP60qSiHuO00025QrE$V" Name="StructuralClass" Description="The structural class defined for the concrete structure (e.g. &apos;1&apos;)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="StructuralGrade_2UyNw8E619$8aLUZDK0aNY" GlobalId="2UyNw8E619$8aLUZDK0aNY" Name="StructuralGrade" Description="Classification label to define mechanical properties according to structural grades defined in published standards; designated by numbers, letters, or a combination of both." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="StructuralSlope_0p7_egygj3puc4u$Co$FM1" GlobalId="0p7_egygj3puc4u$Co$FM1" Name="StructuralSlope" Description="The nominal side slope (allowable steepness) of the pavement structure (not including side slope fill) as a positive ratio measure. The slope information is provided in addition to the shape representation and the geometric parameters used within. In case of inconsistency between the geometric parameters take precedence. Value is typically less than 1.0 (1:1) but may be greater than that for steeper slopes." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="StructuralSlopeType_3xWq8r8qv1fe3unGZTNN_f" GlobalId="3xWq8r8qv1fe3unGZTNN_f" Name="StructuralSlopeType" Description="User defined description on the type of slope used for the pavement structure (not including side slope fill) . Examples are &quot;Even&quot; or &quot;Stepped&quot;." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="StructuralStyle_2xjDwMs_L4qQozvzZdZkMR" GlobalId="2xjDwMs_L4qQozvzZdZkMR" Name="StructuralStyle" Description="Structural style of the element" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="StructuralType_0cKUD5vlD8$g5oDvXR_9FO" GlobalId="0cKUD5vlD8$g5oDvXR_9FO" Name="StructuralType" Description="Structural type of the object" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="Structure_2kWG3nIaXA$fxaD3w_yfmG" GlobalId="2kWG3nIaXA$fxaD3w_yfmG" Name="Structure" Description="State if marking is Structured or not, and what type... e.g. Kamflex, Longflex, Dropflex" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="StructureIndicator_2VKNdQwen0Jf$Mx4BRfVvr" GlobalId="2VKNdQwen0Jf$Mx4BRfVvr" Name="StructureIndicator" Description="The type of bridge structure (composite, coated, homogeneous or other)" TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_StructureIndicator">
						<EnumerationValues>
							<IfcLabel-wrapper>COMPOSITE</IfcLabel-wrapper>
							<IfcLabel-wrapper>COATED</IfcLabel-wrapper>
							<IfcLabel-wrapper>HOMOGENEOUS</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Style_3tLJM0qUWHuO00025QrE$V" GlobalId="3tLJM0qUWHuO00025QrE$V" Name="Style" Description="Description of the furniture style." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="SubmittalIdentifer_155y_nDqr1ZxKrk6Ogjpca" GlobalId="155y_nDqr1ZxKrk6Ogjpca" Name="SubmittalIdentifer" Description="The reference number to an external construction administration submittal used by the construction contractor and/or subcontractor to verify that the referenced IfcProductType/IfcProduct selection conforms with the requirements found in the referenced SpecificationSectionNumber." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="SubstanceDetected_2s7qw0qWKHuO00025QrE$V" GlobalId="2s7qw0qWKHuO00025QrE$V" Name="SubstanceDetected" Description="Identification of the substance that is being detected according to chemical formula. For example, calcium carbonate is &apos;CaCO3&apos;" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="SulphurDioxideEmissions_3$COjWkL9EsA4nTJCFPmTb" GlobalId="3$COjWkL9EsA4nTJCFPmTb" Name="SulphurDioxideEmissions" Description="Rate of emission of sulphur dioxide" TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="SumpHeaterPower_1Gi6i0qSyHuO00025QrE$V" GlobalId="1Gi6i0qSyHuO00025QrE$V" Name="SumpHeaterPower" Description="Electrical heat power of sump heater." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="SumpInvertLevel_1mbbs0qTGHuO00025QrE$V" GlobalId="1mbbs0qTGHuO00025QrE$V" Name="SumpInvertLevel" Description="The lowest point in the cross section of the sump." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="Superelevation_39rujupbvF7OzE476MLsN7" GlobalId="39rujupbvF7OzE476MLsN7" Name="Superelevation" Description="Specifies the superelevation as a ratio measure (slope) at the location of the event." TemplateType="p_singlevalue" PrimaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="SupplyAirConnectionType_2HMxI0qSuHuO00025QrE$V" GlobalId="2HMxI0qSuHuO00025QrE$V" Name="SupplyAirConnectionType" Description="The manner in which the pipe connection is made to the cooled beam." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_CooledBeamSupplyAirConnectionType">
						<EnumerationValues>
							<IfcLabel-wrapper>STRAIGHT</IfcLabel-wrapper>
							<IfcLabel-wrapper>RIGHT</IfcLabel-wrapper>
							<IfcLabel-wrapper>LEFT</IfcLabel-wrapper>
							<IfcLabel-wrapper>TOP</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="SupplyAirTemperatureCooling_0sRf40qRyHuO00025QrE$V" GlobalId="0sRf40qRyHuO00025QrE$V" Name="SupplyAirTemperatureCooling" Description="Supply air temperature in cooling mode." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="SupplyAirTemperatureHeating_0osme0qRyHuO00025QrE$V" GlobalId="0osme0qRyHuO00025QrE$V" Name="SupplyAirTemperatureHeating" Description="Supply air temperature in heating mode." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="SupplyWaterTemperatureCooling_1NYgu0qSuHuO00025QrE$V" GlobalId="1NYgu0qSuHuO00025QrE$V" Name="SupplyWaterTemperatureCooling" Description="Supply water temperature in cooling mode." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="SupplyWaterTemperatureHeating_1Sv$Y0qSuHuO00025QrE$V" GlobalId="1Sv$Y0qSuHuO00025QrE$V" Name="SupplyWaterTemperatureHeating" Description="Supply water temperature in heating mode." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="SupportClass_09LzP6dcn6OAdINBkUxEqS" GlobalId="09LzP6dcn6OAdINBkUxEqS" Name="SupportClass" Description="Specifies a class defining the support measures for underground excavation." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="SupportDescription_01gbdSFfjCmwU9fHFwjDV5" GlobalId="01gbdSFfjCmwU9fHFwjDV5" Name="SupportDescription" Description="Description of Support." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="SupportDescription_2WLzTqjQX4igKvQThEIOuZ" GlobalId="2WLzTqjQX4igKvQThEIOuZ" Name="SupportDescription" Description="Description of Support." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="SupportDuringTransportDescription_3dGrC0qVGHuO00025QrE$V" GlobalId="3dGrC0qVGHuO00025QrE$V" Name="SupportDuringTransportDescription" Description="Textual description of how the concrete element is supported during transportation." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="SupportDuringTransportDocReference_3jEJG0qVGHuO00025QrE$V" GlobalId="3jEJG0qVGHuO00025QrE$V" Name="SupportDuringTransportDocReference" Description="Reference to an external document defining how the concrete element is supported during transportation." TemplateType="p_referencevalue" PrimaryMeasureType="IfcExternalReference" />
				<IfcSimplePropertyTemplate id="SupportedProtocol_0KTh8eeFPDFuFrZpvLZpBP" GlobalId="0KTh8eeFPDFuFrZpvLZpBP" Name="SupportedProtocol" Description="Indicates the protocol supported by the IP network equipment." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="SupportType_1p_mg0qWyHuO00025QrE$V" GlobalId="1p_mg0qWyHuO00025QrE$V" Name="SupportType" Description="Available support types from which that required may be selected." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i1240" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Surface1_3INiE0qUGHuO00025QrE$V" GlobalId="3INiE0qUGHuO00025QrE$V" Name="Surface1" Description="Aspect of weld seam surface, i.e. &apos;plane&apos;, &apos;curved&apos; or &apos;hollow&apos;. Combined welds are given by two corresponding symbols analogous to Type1 and Type2." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="Surface2_3OLAI0qUGHuO00025QrE$V" GlobalId="3OLAI0qUGHuO00025QrE$V" Name="Surface2" Description="See Surface1." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="SurfaceColour_2eQiY0qWSHuO00025QrE$V" GlobalId="2eQiY0qWSHuO00025QrE$V" Name="SurfaceColour" Description="The colour of the surface." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="SurfaceGallingArea_1iJuaHmcrBLxVSLz7TLiKj" GlobalId="1iJuaHmcrBLxVSLz7TLiKj" Name="SurfaceGallingArea" Description="The galling area of the object surface." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAreaMeasure" />
				<IfcSimplePropertyTemplate id="SurfaceSpreadOfFlame_0$6vC0qT0HuO00025QrE$V" GlobalId="0$6vC0qT0HuO00025QrE$V" Name="SurfaceSpreadOfFlame" Description="Indication on how the flames spread around the surface,
It is given according to the national building code that governs the fire behaviour for materials." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="SurfaceSpreadOfFlame_0WEFC0qWWHuO00025QrE$V" GlobalId="0WEFC0qWWHuO00025QrE$V" Name="SurfaceSpreadOfFlame" Description="Indication on how the flames spread around the surface,
It is given according to the national building code that governs the fire behaviour for materials." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="SurfaceSpreadOfFlame_3MLmc0qXKHuO00025QrE$V" GlobalId="3MLmc0qXKHuO00025QrE$V" Name="SurfaceSpreadOfFlame" Description="Indication on how the flames spread around the surface,
It is given according to the national building code that governs the fire behaviour for materials." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="SurfaceTemperature_2Z3ds0qWaHuO00025QrE$V" GlobalId="2Z3ds0qWaHuO00025QrE$V" Name="SurfaceTemperature" Description="Average surface temperature of the component." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="SurveyDimension_3BKUMNltrF3A3l2i5qFCSe" GlobalId="3BKUMNltrF3A3l2i5qFCSe" Name="SurveyDimension" Description="Dimension of the geophysical survey." TemplateType="p_singlevalue" PrimaryMeasureType="IfcInteger" />
				<IfcSimplePropertyTemplate id="SurveyInstrumentManufacturer_0rqYHwzg5EY9Q2cWqaXGxR" GlobalId="0rqYHwzg5EY9Q2cWqaXGxR" Name="SurveyInstrumentManufacturer" Description="Manufacturer of the instrument used in the geophysical survey." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="SurveyInstrumentModel_3DqMDOkJT9PgLG27L3f5fD" GlobalId="3DqMDOkJT9PgLG27L3f5fD" Name="SurveyInstrumentModel" Description="Model/name of the instrument used in the geophysical survey." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="SurveyMethod_0XFkOpEhL5FurL0EyiIIEX" GlobalId="0XFkOpEhL5FurL0EyiIIEX" Name="SurveyMethod" Description="Method of gephysical survey used" TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_GeophysicalSurveyMethod">
						<EnumerationValues>
							<IfcLabel-wrapper>REFLECTION_SEISMIC</IfcLabel-wrapper>
							<IfcLabel-wrapper>REFRACTION_SEISMIC</IfcLabel-wrapper>
							<IfcLabel-wrapper>SURFACEWAVE_SEISMIC</IfcLabel-wrapper>
							<IfcLabel-wrapper>PASSIVE_SEISMIC</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER_SEISMIC</IfcLabel-wrapper>
							<IfcLabel-wrapper>ELECTRICAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>ELECTROMAGNETIC</IfcLabel-wrapper>
							<IfcLabel-wrapper>RADAR</IfcLabel-wrapper>
							<IfcLabel-wrapper>GRAVITY</IfcLabel-wrapper>
							<IfcLabel-wrapper>MAGNETIC</IfcLabel-wrapper>
							<IfcLabel-wrapper>NMR</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="SwaveVelocity_0Zt9yzVWjF3QUsVuryk8eT" GlobalId="0Zt9yzVWjF3QUsVuryk8eT" Name="SwaveVelocity" Description="S-wave velocity of a rock or soil." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLinearVelocityMeasure" />
				<IfcSimplePropertyTemplate id="SwaveVelocity_1LvJ8TerD4XunolAqoyu8J" GlobalId="1LvJ8TerD4XunolAqoyu8J" Name="SwaveVelocity" Description="Value of P wave (pressure or primary elastic body wave (P)) measured through the unit." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLinearVelocityValue" />
				<IfcSimplePropertyTemplate id="Swelling_1PJ_yR2ovAQwJ7uPoRxZb1" GlobalId="1PJ_yR2ovAQwJ7uPoRxZb1" Name="Swelling" Description="Expected swelling behaviour." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="SwellingIndex_2gc$MqEfT7o9RCMSQRED$B" GlobalId="2gc$MqEfT7o9RCMSQRED$B" Name="SwellingIndex" Description="Swelling index is determined with the oedometer test, and used to compute swelling." TemplateType="p_singlevalue" PrimaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="SwitchActivation_20oow0qWuHuO00025QrE$V" GlobalId="20oow0qWuHuO00025QrE$V" Name="SwitchActivation" Description="A list of the available activations for switches from which that required may be selected." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" id="i3319" Name="PEnum_SwitchActivation">
						<EnumerationValues>
							<IfcLabel-wrapper>ACTUATOR</IfcLabel-wrapper>
							<IfcLabel-wrapper>FOOT</IfcLabel-wrapper>
							<IfcLabel-wrapper>HAND</IfcLabel-wrapper>
							<IfcLabel-wrapper>PROXIMITY</IfcLabel-wrapper>
							<IfcLabel-wrapper>SOUND</IfcLabel-wrapper>
							<IfcLabel-wrapper>TWOHAND</IfcLabel-wrapper>
							<IfcLabel-wrapper>WIRE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="SwitchActivation_3zzgE0qWuHuO00025QrE$V" GlobalId="3zzgE0qWuHuO00025QrE$V" Name="SwitchActivation" Description="A list of the available activations for switches from which that required may be selected." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i3319" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="SwitchDisconnectorType_2pTIS0qWuHuO00025QrE$V" GlobalId="2pTIS0qWuHuO00025QrE$V" Name="SwitchDisconnectorType" Description="A list of the available types of switch disconnector from which that required may be selected where:

CenterBreak: A disconnector in which both contacts of each pole are movable and engage at a point substantially midway between their supports. (IEC 441-14-08)
DividedSupport: A disconnector in which the fixed and moving contacts of each pole are not supported by a common base or frame. (IEC 441-14-06)
DoubleBreak: A disconnector that opens a circuit at two points. (IEC 441-14-09)
EarthingSwitch: A disconnector in which the fixed and moving contacts of each pole are not supported by a common base or frame. (IEC 441-14-07)
Isolator: A disconnector which in the open position satisfies isolating requirements. (IEC 441-14-12)" TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_SwitchDisconnectorType">
						<EnumerationValues>
							<IfcLabel-wrapper>CENTERBREAK</IfcLabel-wrapper>
							<IfcLabel-wrapper>DIVIDEDSUPPORT</IfcLabel-wrapper>
							<IfcLabel-wrapper>DOUBLEBREAK</IfcLabel-wrapper>
							<IfcLabel-wrapper>EARTHINGSWITCH</IfcLabel-wrapper>
							<IfcLabel-wrapper>ISOLATOR</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="SwitchFunction_2zul40qWqHuO00025QrE$V" GlobalId="2zul40qWqHuO00025QrE$V" Name="SwitchFunction" Description="Indicates types of switches which differs in functionality." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_SwitchFunctionType">
						<EnumerationValues>
							<IfcLabel-wrapper>ONOFFSWITCH</IfcLabel-wrapper>
							<IfcLabel-wrapper>INTERMEDIATESWITCH</IfcLabel-wrapper>
							<IfcLabel-wrapper>DOUBLETHROWSWITCH</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="SwitchOperation_0bcJm0qWuHuO00025QrE$V" GlobalId="0bcJm0qWuHuO00025QrE$V" Name="SwitchOperation" Description="Indicates operation of emergency stop switch." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_SwitchingDeviceEmergencyStopType">
						<EnumerationValues>
							<IfcLabel-wrapper>MUSHROOM</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="SwitchUsage_1m6hY0qWuHuO00025QrE$V" GlobalId="1m6hY0qWuHuO00025QrE$V" Name="SwitchUsage" Description="A list of the available usages for switches from which that required may be selected." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" id="i3328" Name="PEnum_SwitchUsage">
						<EnumerationValues>
							<IfcLabel-wrapper>EMERGENCY</IfcLabel-wrapper>
							<IfcLabel-wrapper>GUARD</IfcLabel-wrapper>
							<IfcLabel-wrapper>LIMIT</IfcLabel-wrapper>
							<IfcLabel-wrapper>START</IfcLabel-wrapper>
							<IfcLabel-wrapper>STOP</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="SwitchUsage_3jtiG0qWuHuO00025QrE$V" GlobalId="3jtiG0qWuHuO00025QrE$V" Name="SwitchUsage" Description="A list of the available usages for switches from which that required may be selected." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i3328" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Symbol_1e6VoJKif46hPnVSUT$o5u" GlobalId="1e6VoJKif46hPnVSUT$o5u" Name="Symbol" Description="Content which is shown on the sign, e.g. text, number, arrow or icon. The string can also be a pointer to a symbol catalog." TemplateType="p_referencevalue" PrimaryMeasureType="IfcExternalReference" />
				<IfcSimplePropertyTemplate id="System_0aojTM4Y5Fru_D_RsVHF_N" GlobalId="0aojTM4Y5Fru_D_RsVHF_N" Name="System" Description="The building service system that requires the provision for voids, e.g. &apos;Air Conditioning&apos;, &apos;Plumbing&apos;, &apos;Electro&apos;, etc.

Reference to the building service is done using the Name attribute." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="System_1o35c0qSKHuO00025QrE$V" GlobalId="1o35c0qSKHuO00025QrE$V" Name="System" Description="he building service system that requires the provision for voids, e.g. &apos;Air Conditioning&apos;, &apos;Plumbing&apos;, &apos;Electro&apos;, etc." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="T2_1WadG0qVmHuO00025QrE$V" GlobalId="1WadG0qVmHuO00025QrE$V" Name="T2" Description="The (thermal) testing time in [s] associated with the testing currents I1 and I2." TemplateType="p_singlevalue" PrimaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="T2_3zxQW0qVmHuO00025QrE$V" GlobalId="3zxQW0qVmHuO00025QrE$V" Name="T2" Description="The (thermal) testing time in [s] associated with the testing currents I1 and I2." TemplateType="p_singlevalue" PrimaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="T5_20APo0qVmHuO00025QrE$V" GlobalId="20APo0qVmHuO00025QrE$V" Name="T5" Description="The electromagnetic testing time in [s] associated with the testing currents I4 and I5, i.e. electromagnetic tripping time" TemplateType="p_singlevalue" PrimaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="TactileMarking_1z05xhBET6pvjbZKPdkuil" GlobalId="1z05xhBET6pvjbZKPdkuil" Name="TactileMarking" Description="The kind of Tactile Marking of the element." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="TagNumber_3eCIF8g3jEwAYZHzzhJlS$" GlobalId="3eCIF8g3jEwAYZHzzhJlS$" Name="TagNumber" Description="Tag number." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="TailDiameter_2tFbGzZPnF$90SySo7d0Sb" GlobalId="2tFbGzZPnF$90SySo7d0Sb" Name="TailDiameter" Description="Diameter of the tail" TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="TailLength_0XwZqNndfAIBo5xGHS38oI" GlobalId="0XwZqNndfAIBo5xGHS38oI" Name="TailLength" Description="Length of the tail" TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="TailStrength_1U7sKfCoj6xOTd67x3PDsQ" GlobalId="1U7sKfCoj6xOTd67x3PDsQ" Name="TailStrength" Description="Breaking load of the tail (note that ultimate stress is not part of any of the material Psets)" TemplateType="p_singlevalue" PrimaryMeasureType="IfcForceMeasure" />
				<IfcSimplePropertyTemplate id="TailType_1E8vVc_qv18OjQ$L$G70rd" GlobalId="1E8vVc_qv18OjQ$L$G70rd" Name="TailType" Description="Mooring tail type" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="TAMTubesSpacing_3crl3aiib4G91_PCrBXmy0" GlobalId="3crl3aiib4G91_PCrBXmy0" Name="TAMTubesSpacing" Description="Spacing between the tubes Tubes á manchette (TAM)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="TankComposition_2Who80qWyHuO00025QrE$V" GlobalId="2Who80qWyHuO00025QrE$V" Name="TankComposition" Description="Defines the level of element composition where.

COMPLEX: A set of elementary units aggregated together to fulfill the overall  required purpose.
ELEMENT: A single elementary unit that may exist of itself or as an aggregation of partial units..
PARTIAL: A partial elementary unit." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_TankComposition">
						<EnumerationValues>
							<IfcLabel-wrapper>COMPLEX</IfcLabel-wrapper>
							<IfcLabel-wrapper>ELEMENT</IfcLabel-wrapper>
							<IfcLabel-wrapper>PARTIAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="TankNominalCapacity_06cwc0qX0HuO00025QrE$V" GlobalId="06cwc0qX0HuO00025QrE$V" Name="TankNominalCapacity" Description="The total nominal or design volumetric capacity of the tank." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumeMeasure" />
				<IfcSimplePropertyTemplate id="TargetPerformance_3YBpMKO1H0zhLW9cAjhxfY" GlobalId="3YBpMKO1H0zhLW9cAjhxfY" Name="TargetPerformance" Description="Target capacity or performance of the asset. Units of the performance value are specified through the propertyValue units attribute." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="TechnicalStandard_2M$Q1oBlHFBhUArnmHLc4W" GlobalId="2M$Q1oBlHFBhUArnmHLc4W" Name="TechnicalStandard" Description="The technical standard which the element should comply with." TemplateType="p_referencevalue" PrimaryMeasureType="IfcExternalReference" />
				<IfcSimplePropertyTemplate id="TelephoneNumbers_3ITvlLFlfF6Pxp6nE5VY9V" GlobalId="3ITvlLFlfF6Pxp6nE5VY9V" Name="TelephoneNumbers" Description="The list of telephone numbers at which telephone messages may be received." TemplateType="p_listvalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="Temperature_0GSjm0qXCHuO00025QrE$V" GlobalId="0GSjm0qXCHuO00025QrE$V" Name="Temperature" Description="Temperature of the fluid.

Indicates the current measured temperature." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="Temperature_2sotI3fbrBrQnbKR204MCZ" GlobalId="2sotI3fbrBrQnbKR204MCZ" Name="Temperature" Description="Temperature of the fluid." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="Temperature_2X4Q_Kl0H0EBR1WDZY8wN$" GlobalId="2X4Q_Kl0H0EBR1WDZY8wN$" Name="Temperature" Description="Temperature of the fluid." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="TemperatureClassification_3xtXO0qWaHuO00025QrE$V" GlobalId="3xtXO0qWaHuO00025QrE$V" Name="TemperatureClassification" Description="Enumeration defining the temperature classification of the space heater surface temperature.
low temperature - surface temperature is relatively low, usually heated by hot water or electricity.
high temperature - surface temperature is relatively high, usually heated by gas or steam." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_SpaceHeaterTemperatureClassification">
						<EnumerationValues>
							<IfcLabel-wrapper>LOWTEMPERATURE</IfcLabel-wrapper>
							<IfcLabel-wrapper>HIGHTEMPERATURE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="TemperatureDuringInstallation_3vvVR5txv9mvLBcLLN7XJV" GlobalId="3vvVR5txv9mvLBcLLN7XJV" Name="TemperatureDuringInstallation" Description="Normalised working temperature." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="TemperatureEffectiveness_1dcv40qS0HuO00025QrE$V" GlobalId="1dcv40qS0HuO00025QrE$V" Name="TemperatureEffectiveness" Description="Temperature heat transfer effectiveness: The ratio of primary airflow temperature changes to maximum possible temperature changes." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="TemperatureFactor_09GDE0qVqHuO00025QrE$V" GlobalId="09GDE0qVqHuO00025QrE$V" Name="TemperatureFactor" Description="The correction factor (typically measured as %/deg K) for adjusting the thermal current/time to an ambient temperature different from the value given by the defined temperature." TemplateType="p_singlevalue" PrimaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="TemperatureFactor_1ku900qVmHuO00025QrE$V" GlobalId="1ku900qVmHuO00025QrE$V" Name="TemperatureFactor" Description="The correction factor (typically measured as %/deg K) for adjusting the thermal current/time to an ambient temperature different from the value given by the defined temperature." TemplateType="p_singlevalue" PrimaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="TemperatureHistory_3Bw5L2Vz5DeAATs0TdVhIf" GlobalId="3Bw5L2Vz5DeAATs0TdVhIf" Name="TemperatureHistory" Description="Temperature of the fluid. For air this value represents the dry bulb temperature." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="TemperatureMax_3R51p1q1j1nB$j77VpxtSX" GlobalId="3R51p1q1j1nB$j77VpxtSX" Name="TemperatureMax" Description="Maximal temperature of the space or zone, that is required from user/designer view point. If no summer or winter space temperature requirements are given, it applies all year, otherwise for the intermediate period." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="TemperatureMin_0axtJG7wX0cAvo6TTj6AtN" GlobalId="0axtJG7wX0cAvo6TTj6AtN" Name="TemperatureMin" Description="Minimal temperature of the space or zone, that is required from user/designer view point. If no summer or winter space temperature requirements are given, it applies all year, otherwise for the intermediate period." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="TemperatureRange_0bs0u0qVCHuO00025QrE$V" GlobalId="0bs0u0qVCHuO00025QrE$V" Name="TemperatureRange" Description="Allowable maximum and minimum temperature." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="TemperatureRange_0F9xm0qTyHuO00025QrE$V" GlobalId="0F9xm0qTyHuO00025QrE$V" Name="TemperatureRange" Description="Allowable maximum and minimum temperature." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="TemperatureRange_0XxS40qTuHuO00025QrE$V" GlobalId="0XxS40qTuHuO00025QrE$V" Name="TemperatureRange" Description="Allowable maximum and minimum temperature." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="TemperatureRange_1CXKq0qT4HuO00025QrE$V" GlobalId="1CXKq0qT4HuO00025QrE$V" Name="TemperatureRange" Description="Allowable maximum and minimum temperature." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="TemperatureRange_2_L9i0qRyHuO00025QrE$V" GlobalId="2_L9i0qRyHuO00025QrE$V" Name="TemperatureRange" Description="Allowable maximum and minimum temperature.

Temperature range within which the air terminal is designed to operate." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="TemperatureRange_2S7aM0qTuHuO00025QrE$V" GlobalId="2S7aM0qTuHuO00025QrE$V" Name="TemperatureRange" Description="Allowable maximum and minimum temperature." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="TemperatureRange_2tu1Q0qVCHuO00025QrE$V" GlobalId="2tu1Q0qVCHuO00025QrE$V" Name="TemperatureRange" Description="Allowable maximum and minimum temperature." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="TemperatureRange_3jriW0qVuHuO00025QrE$V" GlobalId="3jriW0qVuHuO00025QrE$V" Name="TemperatureRange" Description="Allowable maximum and minimum temperature.

Allowable operational range of the fluid temperature." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="TemperatureRating_1P2QM0qT4HuO00025QrE$V" GlobalId="1P2QM0qT4HuO00025QrE$V" Name="TemperatureRating" Description="Temperature rating." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="TemperatureSensorType_21NyS0qWOHuO00025QrE$V" GlobalId="21NyS0qWOHuO00025QrE$V" Name="TemperatureSensorType" Description="Enumeration that Identifies the types of temperature sensor that can be specified." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_TemperatureSensorType">
						<EnumerationValues>
							<IfcLabel-wrapper>HIGHLIMIT</IfcLabel-wrapper>
							<IfcLabel-wrapper>LOWLIMIT</IfcLabel-wrapper>
							<IfcLabel-wrapper>OUTSIDETEMPERATURE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OPERATINGTEMPERATURE</IfcLabel-wrapper>
							<IfcLabel-wrapper>ROOMTEMPERATURE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="TemperatureSetPoint_11r$fQ7KjDlvSpQ7GrrYIJ" GlobalId="11r$fQ7KjDlvSpQ7GrrYIJ" Name="TemperatureSetPoint" Description="The temperature setpoint range and default setpoint." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="TemperatureSetPoint_3N_YJBMXv4rv$PWDUvcSff" GlobalId="3N_YJBMXv4rv$PWDUvcSff" Name="TemperatureSetPoint" Description="The temperature setpoint range and default setpoint." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="TemperatureSummerMax_0rAvWFO9T46xDQqTZIY75g" GlobalId="0rAvWFO9T46xDQqTZIY75g" Name="TemperatureSummerMax" Description="Maximal temperature of the space or zone for the hot (summer) period, that is required from user/designer view point and provided as requirement for cooling." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="TemperatureSummerMin_1EHskDhor4nBUoFSC6S$Bo" GlobalId="1EHskDhor4nBUoFSC6S$Bo" Name="TemperatureSummerMin" Description="Minimal temperature of the space or zone for the hot (summer) period, that is required from user/designer view point and provided as requirement for cooling." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="TemperatureWinterMax_0Yn52YjwzE59Ibetj1A02E" GlobalId="0Yn52YjwzE59Ibetj1A02E" Name="TemperatureWinterMax" Description="Maximal temperature of the space or zone for the cold (winter) period, that is required from user/designer view point and provided as requirement for heating." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="TemperatureWinterMin_2hL5w3nqP2ivONJzi0p2Qa" GlobalId="2hL5w3nqP2ivONJzi0p2Qa" Name="TemperatureWinterMin" Description="Minimal temperature of the space or zone for the cold (winter) period, that is required from user/designer view point and provided as requirement for heating." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="TendonRelaxation_3Ry2U0qVGHuO00025QrE$V" GlobalId="3Ry2U0qVGHuO00025QrE$V" Name="TendonRelaxation" Description="The maximum allowable relaxation of the tendon (usually expressed as %/1000 h).This property applies to prestressed concrete elements only." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="TensileStrength_0hLYMBp_XD19T1MBlKy5SN" GlobalId="0hLYMBp_XD19T1MBlKy5SN" Name="TensileStrength" Description="Indicates the ability to withstand breakage apart under applied force." TemplateType="p_tablevalue" PrimaryMeasureType="IfcPositivePlaneAngleMeasure" SecondaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="TensileStrength_1O$ABuTcL8EfGi9YcYYahh" GlobalId="1O$ABuTcL8EfGi9YcYYahh" Name="TensileStrength" Description="Defining values: α; defined values: tensile strength." TemplateType="p_tablevalue" PrimaryMeasureType="IfcPositivePlaneAngleMeasure" SecondaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="TensileStrength_1rOUUKaLX2jg4ES1N0oyri" GlobalId="1rOUUKaLX2jg4ES1N0oyri" Name="TensileStrength" Description="Indicates the ability to withstand breakage apart under applied force." TemplateType="p_tablevalue" PrimaryMeasureType="IfcPressureMeasure" SecondaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="TensileStrength_1ZuJdL4cPBOuLWEzKCV5K4" GlobalId="1ZuJdL4cPBOuLWEzKCV5K4" Name="TensileStrength" Description="Indicates the ability to withstand breakage apart under applied force." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="TensileStrength_2AKW2E71v4SwZRSf6Bjv2w" GlobalId="2AKW2E71v4SwZRSf6Bjv2w" Name="TensileStrength" Description="Tensile strength, α=0°." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="TensileStrength_2alM0KcOr709AqqhRTMkwv" GlobalId="2alM0KcOr709AqqhRTMkwv" Name="TensileStrength" Description="Defining values: α; defined values: tensile strength." TemplateType="p_tablevalue" PrimaryMeasureType="IfcPositivePlaneAngleMeasure" SecondaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="TensileStrength_2Kfn$eiOHEthaq0Mv3o6t4" GlobalId="2Kfn$eiOHEthaq0Mv3o6t4" Name="TensileStrength" Description="Indicates the ability to withstand breakage apart under applied force." TemplateType="p_singlevalue" PrimaryMeasureType="IfcForceMeasure" />
				<IfcSimplePropertyTemplate id="TensileStrength_2kzyYyrpv3JQ8F$F0Erxgy" GlobalId="2kzyYyrpv3JQ8F$F0Erxgy" Name="TensileStrength" Description="Defining values: α; defined values: tensile strength." TemplateType="p_tablevalue" PrimaryMeasureType="IfcPositivePlaneAngleMeasure" SecondaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="TensileStrength_2XtnNJoVnBmvn1bzc1UGu_" GlobalId="2XtnNJoVnBmvn1bzc1UGu_" Name="TensileStrength" Description="Tensile strength, α=0°." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="TensileStrengthPerp_0j8x5DwHH4rgxxNUUYpaxH" GlobalId="0j8x5DwHH4rgxxNUUYpaxH" Name="TensileStrengthPerp" Description="Tensile strength, α=90°." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="TensileStrengthPerp_1_0o7uYgT6WBo3VRKcYGm2" GlobalId="1_0o7uYgT6WBo3VRKcYGm2" Name="TensileStrengthPerp" Description="Tensile strength, α=90°." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="TensileStrengthPerp_18d5bAXcjCAARdYXKP07Yn" GlobalId="18d5bAXcjCAARdYXKP07Yn" Name="TensileStrengthPerp" Description="Tensile strength, α=90°." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="TensionForce_3lnzOYG$X5VBKKmCOmDCiI" GlobalId="3lnzOYG$X5VBKKmCOmDCiI" Name="TensionForce" Description="The maximum allowed tension force that can be applied on the tendon." TemplateType="p_singlevalue" PrimaryMeasureType="IfcForceMeasure" />
				<IfcSimplePropertyTemplate id="TensioningWorkingRange_1hZAN9lSb1$gRZ34AI$nMh" GlobalId="1hZAN9lSb1$gRZ34AI$nMh" Name="TensioningWorkingRange" Description="The working range of the tensioning equipment under normal operation." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcForceMeasure" />
				<IfcSimplePropertyTemplate id="TensionLength_1d74zz$bb9fhB4vQYs3GO$" GlobalId="1d74zz$bb9fhB4vQYs3GO$" Name="TensionLength" Description="Length of overhead contactline between two terminating points. It is a design parameter for the overhead contactline system." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="TenureModesAvailableFuture_3n0P80qSKHuO00025QrE$V" GlobalId="3n0P80qSKHuO00025QrE$V" Name="TenureModesAvailableFuture" Description="A list of the tenure modes that are expected to be available in the future expressed in terms of IfcLabel." TemplateType="p_listvalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="TenureModesAvailableNow_3PAWu0qSKHuO00025QrE$V" GlobalId="3PAWu0qSKHuO00025QrE$V" Name="TenureModesAvailableNow" Description="A list of the tenure modes that are currently available expressed in terms of IfcLabel." TemplateType="p_listvalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="TerminalType_39wtrejBf7PuCumwJUl9Gt" GlobalId="39wtrejBf7PuCumwJUl9Gt" Name="TerminalType" Description="Specifies the kind of terminal if IsTerminal is true." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="TerminationDate_1tDim0qVWHuO00025QrE$V" GlobalId="1tDim0qVWHuO00025QrE$V" Name="TerminationDate" Description="Date on which the agreement terminates." TemplateType="p_singlevalue" PrimaryMeasureType="IfcDate" />
				<IfcSimplePropertyTemplate id="TestedMaterial_1mdH_msufC_uxo9bDOdV6V" GlobalId="1mdH_msufC_uxo9bDOdV6V" Name="TestedMaterial" Description="Description of the tested material, e.g. according to existing rock and soil classification systems." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="TestMethod_2o1_k$NgPFVvqCCR6GOF$0" GlobalId="2o1_k$NgPFVvqCCR6GOF$0" Name="TestMethod" Description="The test method used." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="TestMethod_3AtmxC_ubC0PKlPID5SFFu" GlobalId="3AtmxC_ubC0PKlPID5SFFu" Name="TestMethod" Description="Name of the test method that was used to optain the exchanged results." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="TestPressure_1uTV80qXGHuO00025QrE$V" GlobalId="1uTV80qXGHuO00025QrE$V" Name="TestPressure" Description="The maximum pressure to which the valve has been subjected under test." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="TestStandard_1dl93$6LnCXAW8eMV0BT07" GlobalId="1dl93$6LnCXAW8eMV0BT07" Name="TestStandard" Description="Reference to standard that describes the test merthodology." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="TestType_0bwKXZ2_vEmREG23P2KV6g" GlobalId="0bwKXZ2_vEmREG23P2KV6g" Name="TestType" Description="The test type." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="TestType_0R_wrpT5H45vAClA39wdC1" GlobalId="0R_wrpT5H45vAClA39wdC1" Name="TestType" Description="Discipline responsible for performing the tests and using ist results." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="TeTime_3uWcI0qU0HuO00025QrE$V" GlobalId="3uWcI0qU0HuO00025QrE$V" Name="TeTime" Description="The maximum time (in s) at which the motor could run with locked rotor when the motor is used in an EX-environment. The time indicates that a protective device should trip before this time when the starting current of the motor is slowing through the device." TemplateType="p_singlevalue" PrimaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="Text_3hqugetTP6y8gQM8yBm9Ml" GlobalId="3hqugetTP6y8gQM8yBm9Ml" Name="Text" Description="Text content" TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="Texture_3y575Chyb3lBXIjLdtKF9h" GlobalId="3y575Chyb3lBXIjLdtKF9h" Name="Texture" Description="Stratum texture" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ThermalConductivity_0Nqxw0qUuHuO00025QrE$V" GlobalId="0Nqxw0qUuHuO00025QrE$V" Name="ThermalConductivity" Description="The thermal conductivity of the object.

The rate at which thermal energy is transmitted through the material." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermalConductivityMeasure" />
				<IfcSimplePropertyTemplate id="ThermalConductivity_1wrqo0qX8HuO00025QrE$V" GlobalId="1wrqo0qX8HuO00025QrE$V" Name="ThermalConductivity" Description="The thermal conductivity of the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermalConductivityMeasure" />
				<IfcSimplePropertyTemplate id="ThermalConductivity_3RPec0qX8HuO00025QrE$V" GlobalId="3RPec0qX8HuO00025QrE$V" Name="ThermalConductivity" Description="The thermal conductivity of the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermalConductivityMeasure" />
				<IfcSimplePropertyTemplate id="ThermalConductivityTemperatureDerivative_0U5Mi0qUqHuO00025QrE$V" GlobalId="0U5Mi0qUqHuO00025QrE$V" Name="ThermalConductivityTemperatureDerivative" Description="Thermal conductivity temperature derivative." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="ThermalEfficiency_1Zb640qWeHuO00025QrE$V" GlobalId="1Zb640qWeHuO00025QrE$V" Name="ThermalEfficiency" Description="Overall Thermal Efficiency is defined as gross energy output of the heat transfer device divided by the energy input." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="ThermalExpansionCoefficient_2BAG20qUqHuO00025QrE$V" GlobalId="2BAG20qUqHuO00025QrE$V" Name="ThermalExpansionCoefficient" Description="Quantity characterizing the variation with thermodynamic temperature T of the distance l between two points of a body, under given conditions (IEC 113-04-27). The ratio is defined per Kelvin." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermalExpansionCoefficientMeasure" />
				<IfcSimplePropertyTemplate id="ThermalIrEmissivityBack_2dBA80qUqHuO00025QrE$V" GlobalId="2dBA80qUqHuO00025QrE$V" Name="ThermalIrEmissivityBack" Description="Thermal IR emissivity: back side. Defines the fraction of thermal energy emitted per unit area to &quot;blackbody&quot; at the same temperature, through the &quot;back&quot; side of the material." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="ThermalIrEmissivityFront_2iYUo0qUqHuO00025QrE$V" GlobalId="2iYUo0qUqHuO00025QrE$V" Name="ThermalIrEmissivityFront" Description="Thermal IR emissivity: front side. Defines the fraction of thermal energy emitted per unit area to &quot;blackbody&quot; at the same temperature, through the &quot;front&quot; side of the material." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="ThermalIrTransmittance_2XprU0qUqHuO00025QrE$V" GlobalId="2XprU0qUqHuO00025QrE$V" Name="ThermalIrTransmittance" Description="Thermal IR transmittance at normal incidence. Defines the fraction of thermal energy that passes through per unit area, perpendicular to the surface." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="ThermalMassHeatCapacity_1Ng9y0qWeHuO00025QrE$V" GlobalId="1Ng9y0qWeHuO00025QrE$V" Name="ThermalMassHeatCapacity" Description="Product of component mass and specific heat." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="ThermalTransmittance_0kXmy0qWWHuO00025QrE$V" GlobalId="0kXmy0qWWHuO00025QrE$V" Name="ThermalTransmittance" Description="Thermal transmittance coefficient (U-Value) of an element, within the direction of the thermal flow (including all materials)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermalTransmittanceMeasure" />
				<IfcSimplePropertyTemplate id="ThermalTransmittance_0lbaq0qSGHuO00025QrE$V" GlobalId="0lbaq0qSGHuO00025QrE$V" Name="ThermalTransmittance" Description="Thermal transmittance coefficient (U-Value) of an element, within the direction of the thermal flow (including all materials)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermalTransmittanceMeasure" />
				<IfcSimplePropertyTemplate id="ThermalTransmittance_0nU0I0qVGHuO00025QrE$V" GlobalId="0nU0I0qVGHuO00025QrE$V" Name="ThermalTransmittance" Description="Thermal transmittance coefficient (U-Value) of an element, within the direction of the thermal flow (including all materials)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermalTransmittanceMeasure" />
				<IfcSimplePropertyTemplate id="ThermalTransmittance_0W$kQiRJjCzwqrvSp47kdg" GlobalId="0W$kQiRJjCzwqrvSp47kdg" Name="ThermalTransmittance" Description="Thermal transmittance coefficient (U-Value) of an element." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermalTransmittanceMeasure" />
				<IfcSimplePropertyTemplate id="ThermalTransmittance_12jHS0qTmHuO00025QrE$V" GlobalId="12jHS0qTmHuO00025QrE$V" Name="ThermalTransmittance" Description="Thermal transmittance coefficient (U-Value) of an element, within the direction of the thermal flow (including all materials)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermalTransmittanceMeasure" />
				<IfcSimplePropertyTemplate id="ThermalTransmittance_1AjOo0qSKHuO00025QrE$V" GlobalId="1AjOo0qSKHuO00025QrE$V" Name="ThermalTransmittance" Description="Thermal transmittance coefficient (U-Value) of an element, within the direction of the thermal flow (including all materials)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermalTransmittanceMeasure" />
				<IfcSimplePropertyTemplate id="ThermalTransmittance_1qXAY0qV4HuO00025QrE$V" GlobalId="1qXAY0qV4HuO00025QrE$V" Name="ThermalTransmittance" Description="Thermal transmittance coefficient (U-Value) of an element, within the direction of the thermal flow (including all materials)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermalTransmittanceMeasure" />
				<IfcSimplePropertyTemplate id="ThermalTransmittance_1rA3c0qWSHuO00025QrE$V" GlobalId="1rA3c0qWSHuO00025QrE$V" Name="ThermalTransmittance" Description="Thermal transmittance coefficient (U-Value) of an element, within the direction of the thermal flow (including all materials).

Thermal transmittance coefficient (U-Value) of a material of a certain thickness for this element." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermalTransmittanceMeasure" />
				<IfcSimplePropertyTemplate id="ThermalTransmittance_1Xzda0qSaHuO00025QrE$V" GlobalId="1Xzda0qSaHuO00025QrE$V" Name="ThermalTransmittance" Description="Thermal transmittance coefficient (U-Value) of an element, within the direction of the thermal flow (including all materials)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermalTransmittanceMeasure" />
				<IfcSimplePropertyTemplate id="ThermalTransmittance_1yVI80qSeHuO00025QrE$V" GlobalId="1yVI80qSeHuO00025QrE$V" Name="ThermalTransmittance" Description="Thermal transmittance coefficient (U-Value) of an element, within the direction of the thermal flow (including all materials)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermalTransmittanceMeasure" />
				<IfcSimplePropertyTemplate id="ThermalTransmittance_34Qsk0qW4HuO00025QrE$V" GlobalId="34Qsk0qW4HuO00025QrE$V" Name="ThermalTransmittance" Description="Thermal transmittance coefficient (U-Value) of an element, within the direction of the thermal flow (including all materials)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermalTransmittanceMeasure" />
				<IfcSimplePropertyTemplate id="ThermalTransmittance_3MLW9Uqir2HPZ8iRLwgUEW" GlobalId="3MLW9Uqir2HPZ8iRLwgUEW" Name="ThermalTransmittance" Description="Thermal transmittance coefficient (U-Value) of an element, within the direction of the thermal flow (including all materials)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermalTransmittanceMeasure" />
				<IfcSimplePropertyTemplate id="ThermalTransmittance_3ORfU0qXWHuO00025QrE$V" GlobalId="3ORfU0qXWHuO00025QrE$V" Name="ThermalTransmittance" Description="Thermal transmittance coefficient (U-Value) of an element, within the direction of the thermal flow (including all materials)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermalTransmittanceMeasure" />
				<IfcSimplePropertyTemplate id="ThermalTransmittance_3U5gu0qXKHuO00025QrE$V" GlobalId="3U5gu0qXKHuO00025QrE$V" Name="ThermalTransmittance" Description="Thermal transmittance coefficient (U-Value) of an element, within the direction of the thermal flow (including all materials)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermalTransmittanceMeasure" />
				<IfcSimplePropertyTemplate id="ThermalTransmittance_3YhweyeoP4yfJpfFi81P$3" GlobalId="3YhweyeoP4yfJpfFi81P$3" Name="ThermalTransmittance" Description="Thermal transmittance coefficient (U-Value) of an element, within the direction of the thermal flow (including all materials)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermalTransmittanceMeasure" />
				<IfcSimplePropertyTemplate id="ThermalTransmittanceSummer_2Q1xS0qTqHuO00025QrE$V" GlobalId="2Q1xS0qTqHuO00025QrE$V" Name="ThermalTransmittanceSummer" Description="Thermal transmittance coefficient (U-Value) of a material.
Summer thermal transmittance coefficient of the glazing only, often referred to as (U-value)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermalTransmittanceMeasure" />
				<IfcSimplePropertyTemplate id="ThermalTransmittanceWinter_2UCzI0qTqHuO00025QrE$V" GlobalId="2UCzI0qTqHuO00025QrE$V" Name="ThermalTransmittanceWinter" Description="Thermal transmittance coefficient (U-Value) of a material.
Winter thermal transmittance coefficient of the glazing only, often referred to as (U-value)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcThermalTransmittanceMeasure" />
				<IfcSimplePropertyTemplate id="ThermalTrippingUnitType_3Ziye0qVmHuO00025QrE$V" GlobalId="3Ziye0qVmHuO00025QrE$V" Name="ThermalTrippingUnitType" Description="A list of the available types of thermal tripping unit from which that required may be selected." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ThermalTrippingUnitType">
						<EnumerationValues>
							<IfcLabel-wrapper>NH_FUSE</IfcLabel-wrapper>
							<IfcLabel-wrapper>DIAZED</IfcLabel-wrapper>
							<IfcLabel-wrapper>MINIZED</IfcLabel-wrapper>
							<IfcLabel-wrapper>NEOZED</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ThermometerType_3NSK80qUSHuO00025QrE$V" GlobalId="3NSK80qUSHuO00025QrE$V" Name="ThermometerType" Description="Identifies the means by which temperature is displayed." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ThermometerType">
						<EnumerationValues>
							<IfcLabel-wrapper>DIAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>DIGITAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>STEM</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Thickness_3HtI60qX8HuO00025QrE$V" GlobalId="3HtI60qX8HuO00025QrE$V" Name="Thickness" Description="The geometric thickness of the object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="Thickness1_2vQ8Q_UJv0cR2YYII$qZk3" GlobalId="2vQ8Q_UJv0cR2YYII$qZk3" Name="Thickness1" Description="First thickness parameter of a surface member with varying thickness" TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="Thickness2_05Hc3cHvb68QQzhIbXRNcm" GlobalId="05Hc3cHvb68QQzhIbXRNcm" Name="Thickness2" Description="Second thickness parameter of a surface member with varying thickness" TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="Thickness3_0drSMc4wnCbgTf_mTVte5u" GlobalId="0drSMc4wnCbgTf_mTVte5u" Name="Thickness3" Description="Third thickness parameter of a surface member with varying thickness" TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ThicknessSwelling_1merS0qUuHuO00025QrE$V" GlobalId="1merS0qUuHuO00025QrE$V" Name="ThicknessSwelling" Description="Swelling ratio relative to board depth." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="ThreadDiameter_3dsUg0qV0HuO00025QrE$V" GlobalId="3dsUg0qV0HuO00025QrE$V" Name="ThreadDiameter" Description="Nominal diameter of the thread, if different from the bolt&apos;s overall nominal diameter" TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ThreadLength_3kQ680qV0HuO00025QrE$V" GlobalId="3kQ680qV0HuO00025QrE$V" Name="ThreadLength" Description="Nominal length of the thread" TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ThresholdDepth_0YTLDOcv95LhDSgYmDJB$w" GlobalId="0YTLDOcv95LhDSgYmDJB$w" Name="ThresholdDepth" Description="Depth (dimension in plane perpendicular to door leaf) of the door threshold. Only given if the door lining includes a threshold. If omitted (and with a given value to threshold thickness) it indicates an adjustable depth (i.e. a depth that adjusts to the thickness of the wall into which the occurrence of this door style is inserted)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ThresholdOffset_2vEMEd$u99aB$arE6M66kV" GlobalId="2vEMEd$u99aB$arE6M66kV" Name="ThresholdOffset" Description="Offset (dimension in plane perpendicular to door leaf) of the door threshold. The offset is given as distance to the x axis of the local placement. Only given if the door lining includes a threshold and the parameter is known." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="ThresholdThickness_3NZoBtv0jFB84syr_irEvy" GlobalId="3NZoBtv0jFB84syr_irEvy" Name="ThresholdThickness" Description="Thickness of the door threshold as explained in the figure above. If ThresholdThickness value is 0. (zero) it denotes a door without a threshold (ThresholdDepth shall be set to NIL in this case). If the ThresholdThickness is NIL it denotes that the information about a threshold is not available." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNonNegativeLengthMeasure" />
				<IfcSimplePropertyTemplate id="Throw_1l_iY0qSuHuO00025QrE$V" GlobalId="1l_iY0qSuHuO00025QrE$V" Name="Throw" Description="Distance cooled beam throws the air." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="ThrowLength_3K_l80qRyHuO00025QrE$V" GlobalId="3K_l80qRyHuO00025QrE$V" Name="ThrowLength" Description="The horizontal or vertical axial distance an airstream travels after leaving an AirTerminal before the maximum stream velocity is reduced to a specified terminal velocity under isothermal conditions at the upper value of the AirFlowrateRange." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="TicketProcessingTime_17M9Cc_kz818DfWA4GZJTA" GlobalId="17M9Cc_kz818DfWA4GZJTA" Name="TicketProcessingTime" Description="Indicates the processing time of a ticket." TemplateType="p_singlevalue" PrimaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="TicketProductionSpeed_3x1oxWIPb1Ov7kUFZmUNkg" GlobalId="3x1oxWIPb1Ov7kUFZmUNkg" Name="TicketProductionSpeed" Description="Indicates the production speed of the ticket. It is measured by counting the number of tickets that can be produced per hour." TemplateType="p_singlevalue" PrimaryMeasureType="IfcIntegerCountRateMeasure" />
				<IfcSimplePropertyTemplate id="TicketStuckRatio_3yrQ19j3XCuR09jcP_sUQK" GlobalId="3yrQ19j3XCuR09jcP_sUQK" Name="TicketStuckRatio" Description="Indicates the ratio of tickets being stuck or jammed in the appliance." TemplateType="p_singlevalue" PrimaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="TicketVendingMachineType_1jryyyP5n7IgJiBTSr7Yqz" GlobalId="1jryyyP5n7IgJiBTSr7Yqz" Name="TicketVendingMachineType" Description="Indicates the type of ticket vending machine." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_TicketVendingMachineType">
						<EnumerationValues>
							<IfcLabel-wrapper>TICKETREDEMPTIONMACHINE</IfcLabel-wrapper>
							<IfcLabel-wrapper>TICKETREFUNDINGMACHINE</IfcLabel-wrapper>
							<IfcLabel-wrapper>TICKETVENDINGMACHINE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="TidalRange_3Ekqmkl8vDvOb4TiripBma" GlobalId="3Ekqmkl8vDvOb4TiripBma" Name="TidalRange" Description="Indicative (95%-100%) range between high and low tide levels." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="TileLength_046L_0qT0HuO00025QrE$V" GlobalId="046L_0qT0HuO00025QrE$V" Name="TileLength" Description="Length of tiles. The size information is provided in addition to the shape representation and the geometric parameters used within. In cases of inconsistency between the geometric parameters and the size properties, provided in the attached property set, the geometric parameters take precedence." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="TileWidth_09Tge0qT0HuO00025QrE$V" GlobalId="09Tge0qT0HuO00025QrE$V" Name="TileWidth" Description="Width of tiles. The size information is provided in addition to the shape representation and the geometric parameters used within. In cases of inconsistency between the geometric parameters and the size properties, provided in the attached property set, the geometric parameters take precedence." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="TiltAngle_2p9Ls0qWSHuO00025QrE$V" GlobalId="2p9Ls0qWSHuO00025QrE$V" Name="TiltAngle" Description="The angle of tilt defined in the plane perpendicular to the extrusion axis (X-Axis of the local placement). The angle shall be measured from the orientation of the Z-Axis in the local placement." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="TiltHorizontal_12g1s0qS8HuO00025QrE$V" GlobalId="12g1s0qS8HuO00025QrE$V" Name="TiltHorizontal" Description="Indicates horizontal range for pivoting, where positive values indicate the camera rotating clockwise," TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="TiltVertical_18dVw0qS8HuO00025QrE$V" GlobalId="18dVw0qS8HuO00025QrE$V" Name="TiltVertical" Description="Indicates vertical range for pivoting, where 0.0 is level, +90 degrees is looking up, -90 degrees is looking down." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="TimeAdjustmentRange_3O4zE0qViHuO00025QrE$V" GlobalId="3O4zE0qViHuO00025QrE$V" Name="TimeAdjustmentRange" Description="Upper and lower time adjustment limits for an AdjustmentValueType = RANGE. Note that this property should not have a value for an AdjustmentValueType = LIST." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="TimeAdjustmentRangeStepValue_3VqtW0qViHuO00025QrE$V" GlobalId="3VqtW0qViHuO00025QrE$V" Name="TimeAdjustmentRangeStepValue" Description="Step value of time adjustment for an AdjustmentValueType = RANGE. Note that this property should not have a value for an AdjustmentValueType = LIST." TemplateType="p_singlevalue" PrimaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="TimeAdjustmentValues_3bCCA0qViHuO00025QrE$V" GlobalId="3bCCA0qViHuO00025QrE$V" Name="TimeAdjustmentValues" Description="A list of time adjustment values that may be applied to a tripping unit for an AdjustmentValueType = LIST. A minimum of 1 and a maximum of 16 adjustment values may be specified. Note that this property should not have a value for an AdjustmentValueType = RANGE." TemplateType="p_listvalue" PrimaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="TimeConstant_0iRu40qWKHuO00025QrE$V" GlobalId="0iRu40qWKHuO00025QrE$V" Name="TimeConstant" Description="The time constant of the sensor." TemplateType="p_singlevalue" PrimaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="TimeTolerance1_1qYQO0qViHuO00025QrE$V" GlobalId="1qYQO0qViHuO00025QrE$V" Name="TimeTolerance1" Description="The tolerance for the time of time/current-curve in [%]." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="TimeTolerance1_1wChm0qVeHuO00025QrE$V" GlobalId="1wChm0qVeHuO00025QrE$V" Name="TimeTolerance1" Description="The tolerance for the time of time/current-curve in [%]." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="TimeTolerance1_3eTtw0qVeHuO00025QrE$V" GlobalId="3eTtw0qVeHuO00025QrE$V" Name="TimeTolerance1" Description="The tolerance for the time of time/current-curve in [%]." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="TimeTolerance2_1$tD60qViHuO00025QrE$V" GlobalId="1$tD60qViHuO00025QrE$V" Name="TimeTolerance2" Description="The tolerance for the time of the time/current-curve in [%] valid for currents above TimeToleranceLimit1." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="TimeTolerance2_24xL40qVeHuO00025QrE$V" GlobalId="24xL40qVeHuO00025QrE$V" Name="TimeTolerance2" Description="The tolerance for the time of the time/current-curve in [%] valid for currents above TimeToleranceLimit1." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="TimeTolerance2_3pCXE0qVeHuO00025QrE$V" GlobalId="3pCXE0qVeHuO00025QrE$V" Name="TimeTolerance2" Description="The tolerance for the time of the time/current-curve in [%] valid for currents above TimeToleranceLimit1." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="TimeToleranceLimit1_1vvl20qViHuO00025QrE$V" GlobalId="1vvl20qViHuO00025QrE$V" Name="TimeToleranceLimit1" Description="The current limit in [x In] limiting the application of TimeTolerance1, if any. If the value is set to 0, the value of the TimeTolerance1 is valid for the whole time/current-curve." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="TimeToleranceLimit1_20A9q0qVeHuO00025QrE$V" GlobalId="20A9q0qVeHuO00025QrE$V" Name="TimeToleranceLimit1" Description="The current limit in [x In] limiting the application of TimeTolerance1, if any. If the value is set to 0, the value of the TimeTolerance1 is valid for the whole time/current-curve." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="TimeToleranceLimit1_3kRL_0qVeHuO00025QrE$V" GlobalId="3kRL_0qVeHuO00025QrE$V" Name="TimeToleranceLimit1" Description="The current limit in [x In] limiting the application of TimeTolerance1, if any. If the value is set to 0, the value of the TimeTolerance1 is valid for the whole time/current-curve." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="ToggleSwitchType_3P0Z20qWuHuO00025QrE$V" GlobalId="3P0Z20qWuHuO00025QrE$V" Name="ToggleSwitchType" Description="A list of the available types of toggle switch from which that required may be selected." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_SwitchingDeviceToggleSwitchType">
						<EnumerationValues>
							<IfcLabel-wrapper>BREAKGLASS</IfcLabel-wrapper>
							<IfcLabel-wrapper>CHANGEOVER</IfcLabel-wrapper>
							<IfcLabel-wrapper>KEYOPERATED</IfcLabel-wrapper>
							<IfcLabel-wrapper>MANUALPULL</IfcLabel-wrapper>
							<IfcLabel-wrapper>PUSHBUTTON</IfcLabel-wrapper>
							<IfcLabel-wrapper>PULLCORD</IfcLabel-wrapper>
							<IfcLabel-wrapper>ROCKER</IfcLabel-wrapper>
							<IfcLabel-wrapper>SELECTOR</IfcLabel-wrapper>
							<IfcLabel-wrapper>TWIST</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ToiletPanType_3dbng0qWCHuO00025QrE$V" GlobalId="3dbng0qWCHuO00025QrE$V" Name="ToiletPanType" Description="The property enumeration Pset_ToiletPanTypeEnum defines the types of toilet pan that may be specified within the property set Pset_Toilet:-

Siphonic:   Toilet pan in which excrement is removed by siphonage induced by the flushing water.
Squat:  Toilet pan with an elongated bowl installed with its top edge at or near floor level, so that the user has to squat.
WashDown:   Toilet pan in which excrement is removed by the momentum of the flushing water.
WashOut:    A washdown toilet pan in which excrement falls first into a shallow water filled bowl." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ToiletPanType">
						<EnumerationValues>
							<IfcLabel-wrapper>SIPHONIC</IfcLabel-wrapper>
							<IfcLabel-wrapper>SQUAT</IfcLabel-wrapper>
							<IfcLabel-wrapper>WASHDOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>WASHOUT</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ToiletType_3I8V20qWCHuO00025QrE$V" GlobalId="3I8V20qWCHuO00025QrE$V" Name="ToiletType" Description="Enumeration that defines the types of toilet (water closet) arrangements that may be specified where:-

BedPanWasher: Enclosed soil appliance in which bedpans and urinal bottles are emptied and cleansed.
Chemical: Portable receptacle or soil appliance that receives and retains excrement in either an integral or a separate container, in which it is chemically treated and from which it has to be emptied periodically.
CloseCoupled:   Toilet suite in which a flushing cistern is connected directly to the water closet pan.
LooseCoupled:   Toilet arrangement in which a flushing cistern is connected to the water closet pan through a flushing pipe.
SlopHopper:     Hopper shaped soil appliance with a flushing rim and outlet similar to those of a toilet pan, into which human excrement is emptied for disposal." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ToiletType">
						<EnumerationValues>
							<IfcLabel-wrapper>BEDPANWASHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>CHEMICAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>CLOSECOUPLED</IfcLabel-wrapper>
							<IfcLabel-wrapper>LOOSECOUPLED</IfcLabel-wrapper>
							<IfcLabel-wrapper>SLOPHOPPER</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ToleranceBasis_3afnSSHFLAGQqCq3RLp409" GlobalId="3afnSSHFLAGQqCq3RLp409" Name="ToleranceBasis" Description="Indication of the basis of the tolerance requirement" TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ToleranceBasis">
						<EnumerationValues>
							<IfcLabel-wrapper>ASSEMBLY</IfcLabel-wrapper>
							<IfcLabel-wrapper>DEFLECTION</IfcLabel-wrapper>
							<IfcLabel-wrapper>EXPANSION</IfcLabel-wrapper>
							<IfcLabel-wrapper>SETTLEMENT</IfcLabel-wrapper>
							<IfcLabel-wrapper>APPEARANCE</IfcLabel-wrapper>
							<IfcLabel-wrapper>STRUCTURAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>FUNCTIONALITY</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ToleranceDescription_0p2ln6hpL0funX1LED8$P0" GlobalId="0p2ln6hpL0funX1LED8$P0" Name="ToleranceDescription" Description="General description of the tolerance associated to the element or feature, its source and implications." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="ToppingType_0sYOE0qVKHuO00025QrE$V" GlobalId="0sYOE0qVKHuO00025QrE$V" Name="ToppingType" Description="Defines if a topping is applied and what kind. Values are “Full topping”, “Perimeter Wash”, “None”" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="Torque_2npqC0qRqHuO00025QrE$V" GlobalId="2npqC0qRqHuO00025QrE$V" Name="Torque" Description="Indicates the maximum close-off torque for the actuator." TemplateType="p_singlevalue" PrimaryMeasureType="IfcTorqueMeasure" />
				<IfcSimplePropertyTemplate id="TorqueRange_2ZYo80qT4HuO00025QrE$V" GlobalId="2ZYo80qT4HuO00025QrE$V" Name="TorqueRange" Description="Torque range: minimum operational torque to maximum allowable torque." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcTorqueMeasure" />
				<IfcSimplePropertyTemplate id="TorsionalConstantX_2zYok0qVOHuO00025QrE$V" GlobalId="2zYok0qVOHuO00025QrE$V" Name="TorsionalConstantX" Description="Torsional constant about xs. For example measured in mm4." TemplateType="p_singlevalue" PrimaryMeasureType="IfcMomentOfInertiaMeasure" />
				<IfcSimplePropertyTemplate id="TorsionalSectionModulus_025iS0qVSHuO00025QrE$V" GlobalId="025iS0qVSHuO00025QrE$V" Name="TorsionalSectionModulus" Description="Torsional resistance (about xs). For example measured in mm³." TemplateType="p_singlevalue" PrimaryMeasureType="IfcSectionModulusMeasure" />
				<IfcSimplePropertyTemplate id="TorsionalStrength_0S_uq2KWrCDQRWW5W4PUOa" GlobalId="0S_uq2KWrCDQRWW5W4PUOa" Name="TorsionalStrength" Description="Shear strength in torsion." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="TorsionalStrength_0YBUxt_nfFj8QBbLScheNB" GlobalId="0YBUxt_nfFj8QBbLScheNB" Name="TorsionalStrength" Description="Shear strength in torsion." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="TorsionalStrength_1EHJyVIez4GuVXUZSpQHn3" GlobalId="1EHJyVIez4GuVXUZSpQHn3" Name="TorsionalStrength" Description="Shear strength in torsion." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="TotalAirFlow_1wRz7JaXPEwfdUN5bGZWfM" GlobalId="1wRz7JaXPEwfdUN5bGZWfM" Name="TotalAirFlow" Description="" TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="TotalArea_3gb0e0qWSHuO00025QrE$V" GlobalId="3gb0e0qWSHuO00025QrE$V" Name="TotalArea" Description="Total planned area for the site. Used for programming the site space." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAreaMeasure" />
				<IfcSimplePropertyTemplate id="TotalCoolingCapacity_0vlKa0qSuHuO00025QrE$V" GlobalId="0vlKa0qSuHuO00025QrE$V" Name="TotalCoolingCapacity" Description="Total cooling capacity. This includes cooling capacity of beam and cooling capacity of supply air." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="TotalCoolingLoad_3VaQU0qX0HuO00025QrE$V" GlobalId="3VaQU0qX0HuO00025QrE$V" Name="TotalCoolingLoad" Description="The peak total cooling load for the building, zone or space." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="TotalCoreRecovery_0Q7mU7oh9C1AczkUB_dSwZ" GlobalId="0Q7mU7oh9C1AczkUB_dSwZ" Name="TotalCoreRecovery" Description="Length of core recovered (solid and non-intact) expressed as a ratio of the length of core run." TemplateType="p_singlevalue" PrimaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="TotalEffectiveness_1a20e0qS0HuO00025QrE$V" GlobalId="1a20e0qS0HuO00025QrE$V" Name="TotalEffectiveness" Description="Total heat transfer effectiveness: The ratio of heat transfer to the maximum possible heat transfer." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="TotalEffectivenessTable_22RWM0qS0HuO00025QrE$V" GlobalId="22RWM0qS0HuO00025QrE$V" Name="TotalEffectivenessTable" Description="Total heat transfer effectiveness curve as a function of the primary and secondary air flow rate." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" />
				<IfcSimplePropertyTemplate id="TotalHeatGain_0iSd_0qWiHuO00025QrE$V" GlobalId="0iSd_0qWiHuO00025QrE$V" Name="TotalHeatGain" Description="The total (sensible+latent) amount of heat or energy gained by the space at the time of the space&apos;s peak cooling conditions." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="TotalHeatingCapacity_0yk3c0qSuHuO00025QrE$V" GlobalId="0yk3c0qSuHuO00025QrE$V" Name="TotalHeatingCapacity" Description="Total heating capacity. This includes heating capacity of beam and heating capacity of supply air." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="TotalHeatingLoad_3axl80qX0HuO00025QrE$V" GlobalId="3axl80qX0HuO00025QrE$V" Name="TotalHeatingLoad" Description="The peak total heating load for the building, zone or space." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="TotalHeatLoss_0nDpE0qWiHuO00025QrE$V" GlobalId="0nDpE0qWiHuO00025QrE$V" Name="TotalHeatLoss" Description="The total amount of heat or energy lost by the space at the time of the space&apos;s peak heating conditions." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="TotalHeatTransferRate_1buiK0qU8HuO00025QrE$V" GlobalId="1buiK0qU8HuO00025QrE$V" Name="TotalHeatTransferRate" Description="Total heat transfer rate." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="TotalHeatTransferRate_1xHlU0qS0HuO00025QrE$V" GlobalId="1xHlU0qS0HuO00025QrE$V" Name="TotalHeatTransferRate" Description="Total heat transfer rate." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="TotalLatentLoad_3U4R20qWiHuO00025QrE$V" GlobalId="3U4R20qWiHuO00025QrE$V" Name="TotalLatentLoad" Description="Total energy added or removed from air that affects its humidity or concentration of water vapor. If a value is less than zero (negative), then the thermal load is lost from the space. If a value is greater than zero (positive), then the thermal load is a gain to the space." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="TotalLatentLoadHistory_0RTZu0qWmHuO00025QrE$V" GlobalId="0RTZu0qWmHuO00025QrE$V" Name="TotalLatentLoadHistory" Description="Total energy added or removed from air that affects its humidity or concentration of water vapor. If a value is less than zero (negative), then the thermal load is lost from the space. If a value is greater than zero (positive), then the thermal load is a gain to the space." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="TotalPrimaryEnergyConsumption_048bi0qU8HuO00025QrE$V" GlobalId="048bi0qU8HuO00025QrE$V" Name="TotalPrimaryEnergyConsumption" Description="Quantity of energy used as defined in ISO21930:2007." TemplateType="p_singlevalue" PrimaryMeasureType="IfcEnergyMeasure" />
				<IfcSimplePropertyTemplate id="TotalPrimaryEnergyConsumptionPerUnit_2jjHo0qU4HuO00025QrE$V" GlobalId="2jjHo0qU4HuO00025QrE$V" Name="TotalPrimaryEnergyConsumptionPerUnit" Description="Quantity of energy used as defined in ISO21930:2007." TemplateType="p_singlevalue" PrimaryMeasureType="IfcEnergyMeasure" />
				<IfcSimplePropertyTemplate id="TotalRadiantLoad_3ep4M0qWiHuO00025QrE$V" GlobalId="3ep4M0qWiHuO00025QrE$V" Name="TotalRadiantLoad" Description="Total electromagnetic energy added or removed by emission or absorption. If a value is less than zero (negative), then the thermal load is lost from the space. If a value is greater than zero (positive), then the thermal load is a gain to the space." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="TotalRadiantLoadHistory_0USIw0qWmHuO00025QrE$V" GlobalId="0USIw0qWmHuO00025QrE$V" Name="TotalRadiantLoadHistory" Description="Total electromagnetic energy added or removed by emission or absorption. If a value is less than zero (negative), then the thermal load is lost from the space. If a value is greater than zero (positive), then the thermal load is a gain to the space." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="TotalSensibleHeatGain_0bv0W0qWiHuO00025QrE$V" GlobalId="0bv0W0qWiHuO00025QrE$V" Name="TotalSensibleHeatGain" Description="The total sensible heat or energy gained by the space during the peak cooling conditions." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="TotalSensibleLoad_3MKWm0qWiHuO00025QrE$V" GlobalId="3MKWm0qWiHuO00025QrE$V" Name="TotalSensibleLoad" Description="Total energy added or removed from air that affects its temperature. If a value is less than zero (negative), then the thermal load is lost from the space. If a value is greater than zero (positive), then the thermal load is a gain to the space." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="TotalSensibleLoadHistory_0OUqs0qWmHuO00025QrE$V" GlobalId="0OUqs0qWmHuO00025QrE$V" Name="TotalSensibleLoadHistory" Description="Total energy added or removed from air that affects its temperature. If a value is less than zero (negative), then the thermal load is lost from the space. If a value is greater than zero (positive), then the thermal load is a gain to the space." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="TotalUACurves_0cg7e0qSeHuO00025QrE$V" GlobalId="0cg7e0qSeHuO00025QrE$V" Name="TotalUACurves" Description="Total UA curves, UA - air and water velocities, UA = [(C1 * AirFlowRate\^0.8)\^-1 + (C2 * WaterFlowRate\^0.8)\^-1]\^-1.  Note: as two variables are used, DefiningValues and DefinedValues are null, and values are stored in IfcTable in the following order: AirFlowRate,WaterFlowRate,UA.  The IfcTable is related to IfcPropertyTableValue using IfcMetric and IfcResourceConstraintRelationship." TemplateType="p_tablevalue" PrimaryMeasureType="IfcReal" SecondaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="TotalWattage_2g9fC0qUiHuO00025QrE$V" GlobalId="2g9fC0qUiHuO00025QrE$V" Name="TotalWattage" Description="Wattage on whole lightfitting device with all sources intact." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="TouchScreen_2yG0k0qS8HuO00025QrE$V" GlobalId="2yG0k0qS8HuO00025QrE$V" Name="TouchScreen" Description="Indicates touchscreen support." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_AudioVisualDisplayTouchScreen">
						<EnumerationValues>
							<IfcLabel-wrapper>SINGLETOUCH</IfcLabel-wrapper>
							<IfcLabel-wrapper>MULTITOUCH</IfcLabel-wrapper>
							<IfcLabel-wrapper>NONE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Town_1CTteV4prAAwNrX0E35Hng" GlobalId="1CTteV4prAAwNrX0E35Hng" Name="Town" Description="The name of a town." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="TrackCharacteristic_0usHrhLiDDNf8Mimwaruzl" GlobalId="0usHrhLiDDNf8Mimwaruzl" Name="TrackCharacteristic" Description="Indicates the characteristic of the track." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_TrackCharacteristic">
						<EnumerationValues>
							<IfcLabel-wrapper>NORMAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>RACK</IfcLabel-wrapper>
							<IfcLabel-wrapper>FUNICULAR</IfcLabel-wrapper>
							<IfcLabel-wrapper>RIGIDOVERHEAD</IfcLabel-wrapper>
							<IfcLabel-wrapper>THIRDRAIL</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="TrackElementOrientation_13xvT88Cz9wRdASN0W90_H" GlobalId="13xvT88Cz9wRdASN0W90_H" Name="TrackElementOrientation" Description="Turnout panels can be placed in 2 mirror-symmetric directions in the field. To distinguish both ends of the turnout panel, a definition of an orientation system with respect to the panel is necessary. The orientation defines, if the panel is oriented in a way or opposite with respect to the direction of the alignment/stationing." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_TurnoutPanelOrientation">
						<EnumerationValues>
							<IfcLabel-wrapper>FRONT</IfcLabel-wrapper>
							<IfcLabel-wrapper>BACK</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="TrackExpansion_0vaUGKvwPBQhk6i2nO$f86" GlobalId="0vaUGKvwPBQhk6i2nO$f86" Name="TrackExpansion" Description="In curvature context, bounded value of the expansion distance that can be added to rail gauge." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="TrackFasteningElasticityType_3je6qR3bvASesRirl5KDGp" GlobalId="3je6qR3bvASesRirl5KDGp" Name="TrackFasteningElasticityType" Description="Track fastening elasticity type." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_TrackFasteningElasticityType">
						<EnumerationValues>
							<IfcLabel-wrapper>ELASTIC_FASTENING</IfcLabel-wrapper>
							<IfcLabel-wrapper>RIGID_FASTENING</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="TrackGaugeLength_1v1Jj1_hn3HRQxYEGOBxy0" GlobalId="1v1Jj1_hn3HRQxYEGOBxy0" Name="TrackGaugeLength" Description="Basic track gauge of permanent way." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="TrackID_1QUq47Cd5EufPArQiLv0RG" GlobalId="1QUq47Cd5EufPArQiLv0RG" Name="TrackID" Description="The unique identification number of the track." TemplateType="p_singlevalue" PrimaryMeasureType="IfcIdentifier" />
				<IfcSimplePropertyTemplate id="TrackingIdentifier_16LfS0qVWHuO00025QrE$V" GlobalId="16LfS0qVWHuO00025QrE$V" Name="TrackingIdentifier" Description="The identifier assigned to the agreement for the purposes of tracking." TemplateType="p_singlevalue" PrimaryMeasureType="IfcIdentifier" />
				<IfcSimplePropertyTemplate id="TrackNumber_04f6CUpMXA8hZooEXNRWkz" GlobalId="04f6CUpMXA8hZooEXNRWkz" Name="TrackNumber" Description="Indicates the local identification number of the track." TemplateType="p_singlevalue" PrimaryMeasureType="IfcIdentifier" />
				<IfcSimplePropertyTemplate id="TrackSupportingStructure_0HyLCL3Pz3kwIHGXDrwFlL" GlobalId="0HyLCL3Pz3kwIHGXDrwFlL" Name="TrackSupportingStructure" Description="Indicates the supporting structure for track part." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_TrackSupportingStructure">
						<EnumerationValues>
							<IfcLabel-wrapper>BRIDGE</IfcLabel-wrapper>
							<IfcLabel-wrapper>TUNNEL</IfcLabel-wrapper>
							<IfcLabel-wrapper>CONCRETE</IfcLabel-wrapper>
							<IfcLabel-wrapper>SUBGRADELAYER</IfcLabel-wrapper>
							<IfcLabel-wrapper>TRANSITIONSECTION</IfcLabel-wrapper>
							<IfcLabel-wrapper>ONSPECIALFOUNDATION</IfcLabel-wrapper>
							<IfcLabel-wrapper>PAVEMENT</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="TrackUsage_259p5P3E16WRyNXgledf39" GlobalId="259p5P3E16WRyNXgledf39" Name="TrackUsage" Description="The expected primary usage of the track." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_TrackUsage">
						<EnumerationValues>
							<IfcLabel-wrapper>MAINTRACK</IfcLabel-wrapper>
							<IfcLabel-wrapper>LOCOMOTIVERUNNINGTRACK</IfcLabel-wrapper>
							<IfcLabel-wrapper>REFUGESIDING</IfcLabel-wrapper>
							<IfcLabel-wrapper>ROUNDABOUTLINE</IfcLabel-wrapper>
							<IfcLabel-wrapper>ROLLINGFORBIDDENTRACK</IfcLabel-wrapper>
							<IfcLabel-wrapper>ROLLINGTRACK</IfcLabel-wrapper>
							<IfcLabel-wrapper>LOCOMOTIVESERVICETRACK</IfcLabel-wrapper>
							<IfcLabel-wrapper>LOCOMOTIVEHOLDTRACK</IfcLabel-wrapper>
							<IfcLabel-wrapper>STORAGETRACK</IfcLabel-wrapper>
							<IfcLabel-wrapper>REPAIRSIDING</IfcLabel-wrapper>
							<IfcLabel-wrapper>CONNECTINGLINE</IfcLabel-wrapper>
							<IfcLabel-wrapper>MULTIPLEUNITRUNNINGTRACK</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNTWININGLINE</IfcLabel-wrapper>
							<IfcLabel-wrapper>RECEIVINGDEPARTURETRACK</IfcLabel-wrapper>
							<IfcLabel-wrapper>SWITCHINGLEAD</IfcLabel-wrapper>
							<IfcLabel-wrapper>CATCHSIDING</IfcLabel-wrapper>
							<IfcLabel-wrapper>FREIGHTTRACK</IfcLabel-wrapper>
							<IfcLabel-wrapper>CLASSIFICATIONTRACK</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="TractionForce_1h6R3D6qz8J9tT_sZdxp1y" GlobalId="1h6R3D6qz8J9tT_sZdxp1y" Name="TractionForce" Description="Traction force of the point machine in turnout conversion." TemplateType="p_singlevalue" PrimaryMeasureType="IfcForceMeasure" />
				<IfcSimplePropertyTemplate id="TrafficInterfaceType_3HwCkdfrL8cRT34SaMeiGY" GlobalId="3HwCkdfrL8cRT34SaMeiGY" Name="TrafficInterfaceType" Description="Indicates the type of the device traffic interfaces." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ModemTrafficInterfaceType">
						<EnumerationValues>
							<IfcLabel-wrapper>E1</IfcLabel-wrapper>
							<IfcLabel-wrapper>FASTETHERNET</IfcLabel-wrapper>
							<IfcLabel-wrapper>XDSL</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="TransformationRatio_0z_ZR$vVrEivWXuanAlBNq" GlobalId="0z_ZR$vVrEivWXuanAlBNq" Name="TransformationRatio" Description="The ratio of the actual primary current or voltage to the actual secondary current or voltage." TemplateType="p_singlevalue" PrimaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="TransformationRatio_1OT80gqCT1y89fMoREiKYr" GlobalId="1OT80gqCT1y89fMoREiKYr" Name="TransformationRatio" Description="The ratio of the actual primary current or voltage to the actual secondary current or voltage." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="TransformerVectorGroup_2LM0i803DFiO3qpXrGIAS7" GlobalId="2LM0i803DFiO3qpXrGIAS7" Name="TransformerVectorGroup" Description="List of the possible vector groups for the transformer from which that required may be set. Values in the enumeration list follow a standard international code where the first letter  describes how the primary windings are connected,
the second letter describes how the secondary windings are connected, and the numbers describe the rotation of voltages and currents from the primary to the secondary side in multiples of 30 degrees.

D: means that the windings are delta-connected.
Y: means that the windings are star-connected.
Z: means that the windings are zig-zag connected (a special start-connected providing low reactance of the transformer);
The connectivity is only relevant for three-phase transformers." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_TransformerVectorGroup">
						<EnumerationValues>
							<IfcLabel-wrapper>DD0</IfcLabel-wrapper>
							<IfcLabel-wrapper>DD6</IfcLabel-wrapper>
							<IfcLabel-wrapper>DY5</IfcLabel-wrapper>
							<IfcLabel-wrapper>DY11</IfcLabel-wrapper>
							<IfcLabel-wrapper>YD5</IfcLabel-wrapper>
							<IfcLabel-wrapper>YD11</IfcLabel-wrapper>
							<IfcLabel-wrapper>DZ0</IfcLabel-wrapper>
							<IfcLabel-wrapper>DZ6</IfcLabel-wrapper>
							<IfcLabel-wrapper>YY0</IfcLabel-wrapper>
							<IfcLabel-wrapper>YY6</IfcLabel-wrapper>
							<IfcLabel-wrapper>YZ5</IfcLabel-wrapper>
							<IfcLabel-wrapper>YZ11</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="TransitionSuperelevation_1tKFopZ991qBQ$gAlgfNRm" GlobalId="1tKFopZ991qBQ$gAlgfNRm" Name="TransitionSuperelevation" Description="The type of transition of superelevation from previous event to this one." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_TransitionSuperelevationType">
						<EnumerationValues>
							<IfcLabel-wrapper>LINEAR</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="TransitionWidth_1gW6HLbJfFTQ9qh9wdhLS7" GlobalId="1gW6HLbJfFTQ9qh9wdhLS7" Name="TransitionWidth" Description="The type of transition of width used between the previous event and this event." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_TransitionWidthType">
						<EnumerationValues>
							<IfcLabel-wrapper>CONST</IfcLabel-wrapper>
							<IfcLabel-wrapper>LINEAR</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="TransmissionEfficiency_1Ye$qvI7T6Pg_7_vkyG8B4" GlobalId="1Ye$qvI7T6Pg_7_vkyG8B4" Name="TransmissionEfficiency" Description="Transmission efficiency of the tensioning equipment." TemplateType="p_singlevalue" PrimaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="TransmissionLoss_3JHZdLDLfCYhcj9wzSDlXu" GlobalId="3JHZdLDLfCYhcj9wzSDlXu" Name="TransmissionLoss" Description="Indicates the transmission loss of the leaky coaxial cable (radiating cable)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="TransmissionRate_16aHHnGsH6whp$VLYqdzOc" GlobalId="16aHHnGsH6whp$VLYqdzOc" Name="TransmissionRate" Description="Data transmission rate between the device and the receiving module in bits per second." TemplateType="p_singlevalue" PrimaryMeasureType="IfcIntegerCountRateMeasure" />
				<IfcSimplePropertyTemplate id="TransmissionType_0F7760u3z29Q0oq6yXepYZ" GlobalId="0F7760u3z29Q0oq6yXepYZ" Name="TransmissionType" Description="Indicates the data transmission type of the master unit." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_TransmissionType">
						<EnumerationValues>
							<IfcLabel-wrapper>FIBER</IfcLabel-wrapper>
							<IfcLabel-wrapper>RADIO</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Transmissivity_2iOpQUtFb9RODz2KOn3Z6g" GlobalId="2iOpQUtFb9RODz2KOn3Z6g" Name="Transmissivity" Description="Rate of flow of groundwater under a unit hydraulic gradient through an aquifer of unit width and unit thickness. That is, transmissivity is the product of hydraulic conductivity and thickness of the aquifer. The unit is in m2/second." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="TransmittedBandwidth_2x5FCzOXX65wSk8PZymLiB" GlobalId="2x5FCzOXX65wSk8PZymLiB" Name="TransmittedBandwidth" Description="Indicates the transmitted bandwidth of the master unit." TemplateType="p_singlevalue" PrimaryMeasureType="IfcFrequencyMeasure" />
				<IfcSimplePropertyTemplate id="TransmittedFrequency_0b56gXbrD1LxWzOSRwnBOh" GlobalId="0b56gXbrD1LxWzOSRwnBOh" Name="TransmittedFrequency" Description="Indicates the transmitted frequency used by the master unit." TemplateType="p_singlevalue" PrimaryMeasureType="IfcFrequencyMeasure" />
				<IfcSimplePropertyTemplate id="TransmittedSignal_1zo$ODEpL3mPUPdtAGuFyg" GlobalId="1zo$ODEpL3mPUPdtAGuFyg" Name="TransmittedSignal" Description="Indicates the type or standard of signal transmitted by the master unit." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_TransmittedSignal">
						<EnumerationValues>
							<IfcLabel-wrapper>CDMA</IfcLabel-wrapper>
							<IfcLabel-wrapper>GSM</IfcLabel-wrapper>
							<IfcLabel-wrapper>LTE</IfcLabel-wrapper>
							<IfcLabel-wrapper>TD_SCDMA</IfcLabel-wrapper>
							<IfcLabel-wrapper>WCDMA</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="TransomOffset_0jDD0MGir5iAGDaRD8y3Ve" GlobalId="0jDD0MGir5iAGDaRD8y3Ve" Name="TransomOffset" Description="Offset of the transom (if given) which divides the door leaf from a glazing (or window) above. The offset is given from the bottom of the door opening." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="TransomThickness_0OtuFGWo94LwLOfFn_ymY$" GlobalId="0OtuFGWo94LwLOfFn_ymY$" Name="TransomThickness" Description="Thickness of the transom.

For a door, it is the thickness (width in plane parallel to door leaf) of the transom (if provided - that is, if the TransomOffset attribute is set), which divides the door leaf from a glazing (or window) above. If the TransomThickness is set to zero (and the TransomOffset set to a positive length), then the door is divided vertically into a leaf and transom window area without a physical frame." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNonNegativeLengthMeasure" />
				<IfcSimplePropertyTemplate id="TransomThickness_1HhMZXQO53UghvJldSghYj" GlobalId="1HhMZXQO53UghvJldSghYj" Name="TransomThickness" Description="Thickness of the transom.

For a window, it is the thickness of the transom (horizontal separator of window panels within a window), measured parallel to the window elevation plane. The transom is part of the lining and the transom depth is assumed to be identical to the lining depth. If the TransomThickness is set to zero (and the TransomOffset set to a positive length), then the window is divided vertically without a physical divider." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNonNegativeLengthMeasure" />
				<IfcSimplePropertyTemplate id="TransportationStrength_3XJN80qVGHuO00025QrE$V" GlobalId="3XJN80qVGHuO00025QrE$V" Name="TransportationStrength" Description="The minimum required compressive strength of the concrete required for transportation." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="TransportEquipmentAssemblyType_2rlIrmbVH6IhlLGvYDFRI_" GlobalId="2rlIrmbVH6IhlLGvYDFRI_" Name="TransportEquipmentAssemblyType" Description="Indicates the type of transport equipment assembly." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_TransportEquipmentAssemblyType">
						<EnumerationValues>
							<IfcLabel-wrapper>FIXEDCONFIGURATION</IfcLabel-wrapper>
							<IfcLabel-wrapper>MODULARCONFIGURATION</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="TransportEquipmentType_1O7IGaCufAmeb1bIq4Z1FV" GlobalId="1O7IGaCufAmeb1bIq4Z1FV" Name="TransportEquipmentType" Description="Indicates the type of transport equipment." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_TransportEquipmentType">
						<EnumerationValues>
							<IfcLabel-wrapper>MPLS_TP</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTN</IfcLabel-wrapper>
							<IfcLabel-wrapper>PDH</IfcLabel-wrapper>
							<IfcLabel-wrapper>SDH</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="TransverseBoreholeSpacing_1vnl8FJyvCguD4Xq4zJz5Q" GlobalId="1vnl8FJyvCguD4Xq4zJz5Q" Name="TransverseBoreholeSpacing" Description="Transverse spacing between boreholes." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="TransverseSensitivityRatio_1t8VvJu1T3TPoInQI3Loie" GlobalId="1t8VvJu1T3TPoInQI3Loie" Name="TransverseSensitivityRatio" Description="Indicates the transverse sensitivity ratio of the sensor." TemplateType="p_singlevalue" PrimaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="TrapType_1GEyA0qXSHuO00025QrE$V" GlobalId="1GEyA0qXSHuO00025QrE$V" Name="TrapType" Description="Identifies the predefined types of trap from which the type required may be set." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" id="i3566" Name="PEnum_TrapType">
						<EnumerationValues>
							<IfcLabel-wrapper>NONE</IfcLabel-wrapper>
							<IfcLabel-wrapper>P_TRAP</IfcLabel-wrapper>
							<IfcLabel-wrapper>Q_TRAP</IfcLabel-wrapper>
							<IfcLabel-wrapper>S_TRAP</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="TrapType_25a_20qXOHuO00025QrE$V" GlobalId="25a_20qXOHuO00025QrE$V" Name="TrapType" Description="Identifies the predefined types of trap from which the type required may be set." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i3566" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="TrapType_3TVnS0qXSHuO00025QrE$V" GlobalId="3TVnS0qXSHuO00025QrE$V" Name="TrapType" Description="Identifies the predefined types of trap from which the type required may be set." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i3566" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="TreadLength_1ZIPK0qWqHuO00025QrE$V" GlobalId="1ZIPK0qWqHuO00025QrE$V" Name="TreadLength" Description="Horizontal distance from the front of the thread to the front of the next tread.
The tread length is supposed to be equal for all steps of the stair or stair flight at the walking line." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="TreadLength_3w_hE0qWmHuO00025QrE$V" GlobalId="3w_hE0qWmHuO00025QrE$V" Name="TreadLength" Description="Horizontal distance from the front of the thread to the front of the next tread.
The tread length is supposed to be equal for all steps of the stair or stair flight at the walking line." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="TreadLengthAtInnerSide_244Ug0qWqHuO00025QrE$V" GlobalId="244Ug0qWqHuO00025QrE$V" Name="TreadLengthAtInnerSide" Description="Minimum length of treads at the inner side of the winder.
Only relevant in case of winding flights, for straight flights it is identical with IfcStairFlight.TreadLength. It is a pre-calculated value, in case of inconsistencies, the value derived from the shape representation shall take precedence." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="TreadLengthAtInnerSide_2PbjRdz_nFkPSy0dxSVyGX" GlobalId="2PbjRdz_nFkPSy0dxSVyGX" Name="TreadLengthAtInnerSide" Description="Minimum length of treads at the inner side of the winder.
Only relevant in case of winding flights, for straight flights it is identical with IfcStairFlight.TreadLength. It is a pre-calculated value, in case of inconsistencies, the value derived from the shape representation shall take precedence." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="TreadLengthAtOffset_16YqziDXjCxOL5p4GBJOeT" GlobalId="16YqziDXjCxOL5p4GBJOeT" Name="TreadLengthAtOffset" Description="Length of treads at a given offset.
Walking line position is given by the &apos;WalkingLineOffset&apos;. The resulting value should normally be identical with TreadLength, it may be given in addition, if the walking line offset for building code calculations is different from that used in design." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="TreadLengthAtOffset_1x8Ha0qWqHuO00025QrE$V" GlobalId="1x8Ha0qWqHuO00025QrE$V" Name="TreadLengthAtOffset" Description="Length of treads at a given offset.
Walking line position is given by the &apos;WalkingLineOffset&apos;. The resulting value should normally be identical with TreadLength, it may be given in addition, if the walking line offset for building code calculations is different from that used in design." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="TreatmentHoleCount_3XN76C94L2pvK6fvVtToP7" GlobalId="3XN76C94L2pvK6fvVtToP7" Name="TreatmentHoleCount" Description="Number of boreholes used for treatment." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="TrippingCurve_0mITO0qVeHuO00025QrE$V" GlobalId="0mITO0qVeHuO00025QrE$V" Name="TrippingCurve" Description="A curve that establishes the release time of a tripping unit when a particular prospective current is applied.  Note that the tripping curve is defined within a Cartesian coordinate system and this fact must be asserted within the property set:

(1) Defining value is the Prospective Current which is a list of minimum 2 and maximum 16 numbers providing the currents in [x In] for points in the current/time log/log coordinate space. The curve is drawn as a straight line between two consecutive points.
(2) Defined value is a list of minimum 2 and maximum 16 numbers providing the release_time in [s] for points in the current/time log/log coordinate space. The curve is drawn as a straight line between two consecutive points. Note that a defined interpolation." TemplateType="p_tablevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" SecondaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="TrippingCurveType_0aNXG0qVeHuO00025QrE$V" GlobalId="0aNXG0qVeHuO00025QrE$V" Name="TrippingCurveType" Description="The type of tripping curve that is represented by the property set." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_TrippingCurveType">
						<EnumerationValues>
							<IfcLabel-wrapper>UPPER</IfcLabel-wrapper>
							<IfcLabel-wrapper>LOWER</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="TrippingUnitReleaseCurrent_3BGw_0qVmHuO00025QrE$V" GlobalId="3BGw_0qVmHuO00025QrE$V" Name="TrippingUnitReleaseCurrent" Description="The value of tripping or residual current for which the device has the possibility to be equipped. The values are given in mA." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_TrippingUnitReleaseCurrent">
						<EnumerationValues>
							<IfcLabel-wrapper>10</IfcLabel-wrapper>
							<IfcLabel-wrapper>30</IfcLabel-wrapper>
							<IfcLabel-wrapper>100</IfcLabel-wrapper>
							<IfcLabel-wrapper>300</IfcLabel-wrapper>
							<IfcLabel-wrapper>500</IfcLabel-wrapper>
							<IfcLabel-wrapper>1000</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="TS_3TIrUqMFzEHxl56bjVXyxc" GlobalId="3TIrUqMFzEHxl56bjVXyxc" Name="TS" Description="The total sulfur content. The unit must be defined in _&apos;IfcPropertySingleValue_._Unit&apos;_." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="TubeDiameter_2$VL9j18b63QdizLrkdfFs" GlobalId="2$VL9j18b63QdizLrkdfFs" Name="TubeDiameter" Description="Indicates the diameter of the fiber tubes that are used in the fan out." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="TubeThickness_2$asiH00f8LgpWKouTPJnb" GlobalId="2$asiH00f8LgpWKouTPJnb" Name="TubeThickness" Description="Thickness of the tube." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="TubingLength_2W_Ew0qWeHuO00025QrE$V" GlobalId="2W_Ew0qWeHuO00025QrE$V" Name="TubingLength" Description="Water tube length inside the component." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="TunerChannel_3gSXi0qSCHuO00025QrE$V" GlobalId="3gSXi0qSCHuO00025QrE$V" Name="TunerChannel" Description="Indicates the tuner channels, if applicable." TemplateType="p_tablevalue" PrimaryMeasureType="IfcIdentifier" SecondaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="TunerFrequency_3oCR_0qSCHuO00025QrE$V" GlobalId="3oCR_0qSCHuO00025QrE$V" Name="TunerFrequency" Description="Indicates the tuner frequencies, if applicable." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcFrequencyMeasure" />
				<IfcSimplePropertyTemplate id="TunerMode_3Y6U00qSCHuO00025QrE$V" GlobalId="3Y6U00qSCHuO00025QrE$V" Name="TunerMode" Description="Indicates the tuner modes (or bands). For example, &apos;AnalogCable&apos;, &apos;DigitalAir&apos;, &apos;AM&apos;, &apos;FM&apos;." TemplateType="p_tablevalue" PrimaryMeasureType="IfcIdentifier" SecondaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="TunerType_3JoyG0qSCHuO00025QrE$V" GlobalId="3JoyG0qSCHuO00025QrE$V" Name="TunerType" Description="Indicates the tuner type." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_AudioVisualTunerType">
						<EnumerationValues>
							<IfcLabel-wrapper>AUDIO</IfcLabel-wrapper>
							<IfcLabel-wrapper>VIDEO</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="TunnelExcavationMethod_0IxY668fj68P9Wr33SXafb" GlobalId="0IxY668fj68P9Wr33SXafb" Name="TunnelExcavationMethod" Description="Type of the tunnel excavation method that was applied when the observation was made." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="TunnelInclination_2$VkG7ESn3rQ2WJSlegUBN" GlobalId="2$VkG7ESn3rQ2WJSlegUBN" Name="TunnelInclination" Description="Specifies the tunnel inclination relative to the drive direction as specified by IsDriveDirectedAlongChainage." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_TunnelInclination">
						<EnumerationValues>
							<IfcLabel-wrapper>RISING</IfcLabel-wrapper>
							<IfcLabel-wrapper>FALLING</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="TurnoutCurvedRadius_3FY$OPu$b6J8ZMO7JXyrJe" GlobalId="3FY$OPu$b6J8ZMO7JXyrJe" Name="TurnoutCurvedRadius" Description="If turnout is curved, the main branch radius of curvature." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="TurnoutHeaterType_27rZtIRVj5GBgj9RvjETkL" GlobalId="27rZtIRVj5GBgj9RvjETkL" Name="TurnoutHeaterType" Description="Defines the kind of turnout heater installed." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_TurnoutHeaterType">
						<EnumerationValues>
							<IfcLabel-wrapper>GAS</IfcLabel-wrapper>
							<IfcLabel-wrapper>GEOTHERMAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
							<IfcLabel-wrapper>ELECTRIC</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="TurnoutPointMachineCount_249Cywch9BU9fEWCgPdORK" GlobalId="249Cywch9BU9fEWCgPdORK" Name="TurnoutPointMachineCount" Description="Count of point machines inside turnout panel." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="TurnstileType_3yE$cMPun2Du7wMts2JRaM" GlobalId="3yE$cMPun2Du7wMts2JRaM" Name="TurnstileType" Description="Indicates the type of turnstile gate." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_TurnstileType">
						<EnumerationValues>
							<IfcLabel-wrapper>SWINGGATEBRAKE</IfcLabel-wrapper>
							<IfcLabel-wrapper>THREEPOLEROTARYBRAKE</IfcLabel-wrapper>
							<IfcLabel-wrapper>WINGGATEBRAKE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Twisting_06sdk0qVKHuO00025QrE$V" GlobalId="06sdk0qVKHuO00025QrE$V" Name="Twisting" Description="The angle, in radians, through which the end face of a precast piece is rotated with respect to its starting face, along its longitudinal axis, as a result of non-aligned supports. This measure is also termed the ‘warping’ angle." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="Type_27tqO0qUWHuO00025QrE$V" GlobalId="27tqO0qUWHuO00025QrE$V" Name="Type" Description="Defines the allowed values for selection of the flow meter operation type." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_WaterMeterType">
						<EnumerationValues>
							<IfcLabel-wrapper>COMPOUND</IfcLabel-wrapper>
							<IfcLabel-wrapper>INFERENTIAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>PISTON</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Type1_35GTI0qUGHuO00025QrE$V" GlobalId="35GTI0qUGHuO00025QrE$V" Name="Type1" Description="Type of weld seam according to ISO 2553. Note, combined welds are given by two corresponding symbols in the direction of the normal axis of the coordinate system. For example, an X weld is specified by Type1 = &apos;V&apos; and Type2 = &apos;V&apos;." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="Type2_3CQEA0qUGHuO00025QrE$V" GlobalId="3CQEA0qUGHuO00025QrE$V" Name="Type2" Description="See Type1." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="TypeDesignation_3_nUqKqXv3xheIJewmELBG" GlobalId="3_nUqKqXv3xheIJewmELBG" Name="TypeDesignation" Description="Type designator for the element. The content depends on local standards. Eg. &apos;Bull nose&apos;, &apos;Half batter&apos;, &apos;Dropper&apos;, &apos;Chamfer&apos; etc" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="TypeOfCurvedTurnout_290PDCxijBugy3g08gwk5i" GlobalId="290PDCxijBugy3g08gwk5i" Name="TypeOfCurvedTurnout" Description="Turnouts that are positioned in the curved part of the alignment." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_TypeOfCurvedTurnout">
						<EnumerationValues>
							<IfcLabel-wrapper>STRAIGHT</IfcLabel-wrapper>
							<IfcLabel-wrapper>CIRCULAR_ARC</IfcLabel-wrapper>
							<IfcLabel-wrapper>TRANSITION</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="TypeOfDrivingDevice_18PeDiUi91sfJJk$VA50EV" GlobalId="18PeDiUi91sfJJk$VA50EV" Name="TypeOfDrivingDevice" Description="Type of the driving device used for the turnout." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_TypeOfDrivingDevice">
						<EnumerationValues>
							<IfcLabel-wrapper>ELECTRIC</IfcLabel-wrapper>
							<IfcLabel-wrapper>MANUAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>HYDRAULIC</IfcLabel-wrapper>
							<IfcLabel-wrapper>PNEUMATIC</IfcLabel-wrapper>
							<IfcLabel-wrapper>MIXED</IfcLabel-wrapper>
							<IfcLabel-wrapper>MOTORISED</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="TypeOfJunction_1CPJkVojL2mf9DeSn$IYKu" GlobalId="1CPJkVojL2mf9DeSn$IYKu" Name="TypeOfJunction" Description="The turnout part of the continuous welded rail." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_TypeOfJunction">
						<EnumerationValues>
							<IfcLabel-wrapper>ISOLATED_JOINT</IfcLabel-wrapper>
							<IfcLabel-wrapper>JOINTED</IfcLabel-wrapper>
							<IfcLabel-wrapper>WELDED_AND_INSERTABLE</IfcLabel-wrapper>
							<IfcLabel-wrapper>WELDED_AND_NOT_INSERTABLE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="TypeOfShaft_3CsdA17mP3S96HzWjfIsoL" GlobalId="3CsdA17mP3S96HzWjfIsoL" Name="TypeOfShaft" Description="Additional information on the purpose of the shaft." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_TypeOfShaft">
						<EnumerationValues>
							<IfcLabel-wrapper>SHAFTWITHCHECKVALVE</IfcLabel-wrapper>
							<IfcLabel-wrapper>DIVERSIONSHAFT</IfcLabel-wrapper>
							<IfcLabel-wrapper>FLUSHINGCHAMBER</IfcLabel-wrapper>
							<IfcLabel-wrapper>INSPECTIONCHAMBER</IfcLabel-wrapper>
							<IfcLabel-wrapper>GULLY</IfcLabel-wrapper>
							<IfcLabel-wrapper>SLURRYCOLLECTOR</IfcLabel-wrapper>
							<IfcLabel-wrapper>GATESHAFT</IfcLabel-wrapper>
							<IfcLabel-wrapper>PUMPSHAFT</IfcLabel-wrapper>
							<IfcLabel-wrapper>ROOFWATERSHAFT</IfcLabel-wrapper>
							<IfcLabel-wrapper>WELL</IfcLabel-wrapper>
							<IfcLabel-wrapper>SOAKAWAY</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="TypeOfSupportingSystem_3WKZxWJOXCiOu_tvXdPAUd" GlobalId="3WKZxWJOXCiOu_tvXdPAUd" Name="TypeOfSupportingSystem" Description="Type of foundation in the OCS supporting system." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_SupportingSystemType">
						<EnumerationValues>
							<IfcLabel-wrapper>ENDCATENARYSUPPORT</IfcLabel-wrapper>
							<IfcLabel-wrapper>HEADSPANSUPPORT</IfcLabel-wrapper>
							<IfcLabel-wrapper>HERSE</IfcLabel-wrapper>
							<IfcLabel-wrapper>MULTITRACKSUPPORT</IfcLabel-wrapper>
							<IfcLabel-wrapper>RIGIDGANTRY</IfcLabel-wrapper>
							<IfcLabel-wrapper>SIMPLESUPPORT</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="TypeOfTurnout_2OfaIDftHCpO$ERd0KXnMa" GlobalId="2OfaIDftHCpO$ERd0KXnMa" Name="TypeOfTurnout" Description="Type of turnout." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_TypeOfTurnout">
						<EnumerationValues>
							<IfcLabel-wrapper>DERAILMENT_TURNOUT</IfcLabel-wrapper>
							<IfcLabel-wrapper>SLIP_TURNOUT_AND_SCISSORS_CROSSING</IfcLabel-wrapper>
							<IfcLabel-wrapper>THREE_WAYS_TURNOUT</IfcLabel-wrapper>
							<IfcLabel-wrapper>SYMMETRIC_TURNOUT</IfcLabel-wrapper>
							<IfcLabel-wrapper>SINGLE_SLIP_CROSSING</IfcLabel-wrapper>
							<IfcLabel-wrapper>DOUBLE_SLIP_CROSSING</IfcLabel-wrapper>
							<IfcLabel-wrapper>DIAMOND_CROSSING</IfcLabel-wrapper>
							<IfcLabel-wrapper>SCISSOR_CROSSOVER</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="UACurve_1KG$80qSyHuO00025QrE$V" GlobalId="1KG$80qSyHuO00025QrE$V" Name="UACurve" Description="UA value.

As a function of fan speed at certain water flow rate, UA = f ( fan speed)." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" />
				<IfcSimplePropertyTemplate id="UACurve_2nN9c0qWaHuO00025QrE$V" GlobalId="2nN9c0qWaHuO00025QrE$V" Name="UACurve" Description="UA value.

As a function of ambient temperature and surface temperature; UA = f (Tambient, Tsurface)" TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" />
				<IfcSimplePropertyTemplate id="UAcurves_1sY420qSmHuO00025QrE$V" GlobalId="1sY420qSmHuO00025QrE$V" Name="UAcurves" Description="UV = f (VExterior, VInterior), UV as a function of interior and exterior fluid flow velocity at the entrance." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" />
				<IfcSimplePropertyTemplate id="UAcurves_3XtGq0qU8HuO00025QrE$V" GlobalId="3XtGq0qU8HuO00025QrE$V" Name="UAcurves" Description="UV = f (VExterior, VInterior), UV as a function of interior and exterior fluid flow velocity at the entrance." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" />
				<IfcSimplePropertyTemplate id="UltimateStrain_3VC_K0qUqHuO00025QrE$V" GlobalId="3VC_K0qUqHuO00025QrE$V" Name="UltimateStrain" Description="A measure of the (engineering) strain at the state of ultimate stress of the material." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="UltimateStress_3Prfg0qUqHuO00025QrE$V" GlobalId="3Prfg0qUqHuO00025QrE$V" Name="UltimateStress" Description="A measure of the ultimate stress of the material." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="UltimateTensileStrength_0eJN7IDD15sBhRJRd4TjCU" GlobalId="0eJN7IDD15sBhRJRd4TjCU" Name="UltimateTensileStrength" Description="Indicates the maximum stress that a material or element can withstand before breaking while being stretched or pulled." TemplateType="p_singlevalue" PrimaryMeasureType="IfcForceMeasure" />
				<IfcSimplePropertyTemplate id="UncertaintyBasis_3QSaVp2x1CmfjKyHvaJgfs" GlobalId="3QSaVp2x1CmfjKyHvaJgfs" Name="UncertaintyBasis" Description="Indication of the basis of the uncertainty" TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_UncertaintyBasis">
						<EnumerationValues>
							<IfcLabel-wrapper>MEASUREMENT</IfcLabel-wrapper>
							<IfcLabel-wrapper>OBSERVATION</IfcLabel-wrapper>
							<IfcLabel-wrapper>ASSESSMENT</IfcLabel-wrapper>
							<IfcLabel-wrapper>INTERPRETATION</IfcLabel-wrapper>
							<IfcLabel-wrapper>ESTIMATE</IfcLabel-wrapper>
							<IfcLabel-wrapper>USERDEFINED</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTDEFINED</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="UncertaintyDescription_2rw6tfssL7IgbS7PGZcx6e" GlobalId="2rw6tfssL7IgbS7PGZcx6e" Name="UncertaintyDescription" Description="General description of the uncertainty associated to the element or feature, its source and implications." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="UnconfinedCompressiveStrength_2ZCp5dntj43BvWF_dlBh7I" GlobalId="2ZCp5dntj43BvWF_dlBh7I" Name="UnconfinedCompressiveStrength" Description="The unconfined compressive strength (UCS) is the maximum axial compressive stress that a right-cylindrical sample of material can withstand under unconfined conditions." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="UnconfinedCompressiveStrength_3y02KcJ79CL80neBRiH8Lp" GlobalId="3y02KcJ79CL80neBRiH8Lp" Name="UnconfinedCompressiveStrength" Description="The unconfined compressive strength (UCS) is the maximum axial compressive stress that a right-cylindrical sample of material can withstand under unconfined conditions." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="UndergroundExcavationMethod_0wE_9k6ETFpu7yxLk9g7XY" GlobalId="0wE_9k6ETFpu7yxLk9g7XY" Name="UndergroundExcavationMethod" Description="Method of excavation." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_UndergroundExcavationMethod">
						<EnumerationValues>
							<IfcLabel-wrapper>HAND</IfcLabel-wrapper>
							<IfcLabel-wrapper>EXCAVATOR</IfcLabel-wrapper>
							<IfcLabel-wrapper>JACKHAMMER</IfcLabel-wrapper>
							<IfcLabel-wrapper>RIPPER</IfcLabel-wrapper>
							<IfcLabel-wrapper>DRILLANDBLAST</IfcLabel-wrapper>
							<IfcLabel-wrapper>ROADHEADER</IfcLabel-wrapper>
							<IfcLabel-wrapper>TBMOPENWITHGRIPPERS</IfcLabel-wrapper>
							<IfcLabel-wrapper>TBMCLOSEDWITHGRIPPERS</IfcLabel-wrapper>
							<IfcLabel-wrapper>TBMEARTHPRESSUREFACESUPPORT</IfcLabel-wrapper>
							<IfcLabel-wrapper>TBMSLURRYPRESSUREFACESUPPORT</IfcLabel-wrapper>
							<IfcLabel-wrapper>TBMAIRPRESSUREFACESUPPORT</IfcLabel-wrapper>
							<IfcLabel-wrapper>TBMMIXSHIELD</IfcLabel-wrapper>
							<IfcLabel-wrapper>SHAFTBORINGMACHINE</IfcLabel-wrapper>
							<IfcLabel-wrapper>RAISEDRILL</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="UnderSleeperPadStiffness_0iZmbYaC1AVvSMX_LEPB36" GlobalId="0iZmbYaC1AVvSMX_LEPB36" Name="UnderSleeperPadStiffness" Description="Indicates the stiffness of the under-sleeper pad as design reference for the sleeper." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_UnderSleeperPadStiffness">
						<EnumerationValues>
							<IfcLabel-wrapper>MEDIUM</IfcLabel-wrapper>
							<IfcLabel-wrapper>SOFT</IfcLabel-wrapper>
							<IfcLabel-wrapper>STIFF</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="UndrainedShearStrength_0n38wMri16s8QxCTdB1sg_" GlobalId="0n38wMri16s8QxCTdB1sg_" Name="UndrainedShearStrength" Description="Shear strength of a soil under undrained condition or constant volume conditions. It is relevant for conditions where the rate of loading is very much greater than the rate at which pore water pressure - generated due to the action of shearing of the soil - dissipates.  Its calculation depends on the laboratory test performed." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="UniformlyDistributedLoad_2oFKKjPUb4bA5i8GWGN0uJ" GlobalId="2oFKKjPUb4bA5i8GWGN0uJ" Name="UniformlyDistributedLoad" Description="Uniformly Distributed Load" TemplateType="p_singlevalue" PrimaryMeasureType="IfcForceMeasure" />
				<IfcSimplePropertyTemplate id="UnitaryApplication_2Y52cBoBnCBP7WBI0IJIdu" GlobalId="2Y52cBoBnCBP7WBI0IJIdu" Name="UnitaryApplication" Description="The application of the unitary control element." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_UnitaryControlElementApplication">
						<EnumerationValues>
							<IfcLabel-wrapper>LIFTPOSITIONINDICATOR</IfcLabel-wrapper>
							<IfcLabel-wrapper>LIFTHALLLANTERN</IfcLabel-wrapper>
							<IfcLabel-wrapper>LIFTARRIVALGONG</IfcLabel-wrapper>
							<IfcLabel-wrapper>LIFTCARDIRECTIONLANTERN</IfcLabel-wrapper>
							<IfcLabel-wrapper>LIFTFIRESYSTEMSPORT</IfcLabel-wrapper>
							<IfcLabel-wrapper>LIFTVOICEANNOUNCER</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="UnitDischarge_2j9UjMlrj7DQqFFjx5YGf1" GlobalId="2j9UjMlrj7DQqFFjx5YGf1" Name="UnitDischarge" Description="Volumetric flow rate of water that goes out of an hydrogeologic unit, at potentially multiple locations." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="UnitRecharge_0CjjY8gGfAcQfADgdDjQOz" GlobalId="0CjjY8gGfAcQfADgdDjQOz" Name="UnitRecharge" Description="Volumetric flow rate of water that enters an hydrogeologic unit, at potentially multiple locations." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="UnmitigatedRiskConsequence_1t9ADGHCfFUQZuSCWzXhY3" GlobalId="1t9ADGHCfFUQZuSCWzXhY3" Name="UnmitigatedRiskConsequence" Description="Identifies the consequence of the hazard prior to any specific mitigation." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i2055" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="UnmitigatedRiskLikelihood_1Mb3$S0h15Vue$TBwV26oa" GlobalId="1Mb3$S0h15Vue$TBwV26oa" Name="UnmitigatedRiskLikelihood" Description="Identifies the likelihood of the hazard prior to any specific mitigation." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i2055" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="UnmitigatedRiskSignificance_0e40TDcGfEt9qzhUbiDnYC" GlobalId="0e40TDcGfEt9qzhUbiDnYC" Name="UnmitigatedRiskSignificance" Description="Identifies the significance of the risk given the likelihood and consequence prior to any specific mitigation." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i2055" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="UpdateDate_3JKy7u4y16EgxfwwY7RYg8" GlobalId="3JKy7u4y16EgxfwwY7RYg8" Name="UpdateDate" Description="Date of update of the model." TemplateType="p_singlevalue" PrimaryMeasureType="IfcDate" />
				<IfcSimplePropertyTemplate id="UplinkRadioBand_16u1AonQD7qeK0DpO8DyYZ" GlobalId="16u1AonQD7qeK0DpO8DyYZ" Name="UplinkRadioBand" Description="Indicates the frequency range, delimited by a lower frequency and an upper frequency, allocated for uplink transmission." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcFrequencyMeasure" />
				<IfcSimplePropertyTemplate id="UpperCurrent1_0Hc0y0qViHuO00025QrE$V" GlobalId="0Hc0y0qViHuO00025QrE$V" Name="UpperCurrent1" Description="The current in [x In], indicating that for currents larger than UpperCurrent1 the I2t part of the L-function will trip the current." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="UpperCurrent2_0MzLc0qViHuO00025QrE$V" GlobalId="0MzLc0qViHuO00025QrE$V" Name="UpperCurrent2" Description="The current in [x In], indicating the upper current limit of the upper time/current curve of the I2t part of the L-function." TemplateType="p_singlevalue" PrimaryMeasureType="IfcElectricCurrentMeasure" />
				<IfcSimplePropertyTemplate id="UpperTime1_0SKgG0qViHuO00025QrE$V" GlobalId="0SKgG0qViHuO00025QrE$V" Name="UpperTime1" Description="The time in [s], indicating that tripping times of the upper time/current curve lower than UpperTime1 is determined by the I2t part of the L-function." TemplateType="p_singlevalue" PrimaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="UpperTime2_0Xh_w0qViHuO00025QrE$V" GlobalId="0Xh_w0qViHuO00025QrE$V" Name="UpperTime2" Description="The time in [s], indicating the tripping times of the upper time/current curve at the UpperCurrent2." TemplateType="p_singlevalue" PrimaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="UpperVaporResistanceFactor_1P5vw0qUqHuO00025QrE$V" GlobalId="1P5vw0qUqHuO00025QrE$V" Name="UpperVaporResistanceFactor" Description="The vapor permeability relationship of air/material (typically value &gt; 1), measured in high relative humidity (typically in 95/50 % RH)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="Upstand_3VCJVzwh9CCfDp_58_XB7_" GlobalId="3VCJVzwh9CCfDp_58_XB7_" Name="Upstand" Description="The height difference between the two separated surfaces." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNonNegativeLengthMeasure" />
				<IfcSimplePropertyTemplate id="UpstreamConnections_0gcm8p7cfF28fgCrHyW9Fj" GlobalId="0gcm8p7cfF28fgCrHyW9Fj" Name="UpstreamConnections" Description="Names of upstream connected equipment and spaces, if not otherwise represented" TemplateType="p_listvalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="UpstreamFloodWaterLevel_0OpoEwb5L2EudbjvkVhtcK" GlobalId="0OpoEwb5L2EudbjvkVhtcK" Name="UpstreamFloodWaterLevel" Description="Design maximum upstream water level for the lock complex" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="UpstreamMaintenanceWaterLevel_0F2UdpFPTApeBET26XpMXu" GlobalId="0F2UdpFPTApeBET26XpMXu" Name="UpstreamMaintenanceWaterLevel" Description="Design maximum upstream water level for the lock complex" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="UpstreamPressure_1Pn2i0qXKHuO00025QrE$V" GlobalId="1Pn2i0qXKHuO00025QrE$V" Name="UpstreamPressure" Description="The operating pressure of the fluid upstream of the pressure reducing valve." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="UrinalType_0r4uU0qWGHuO00025QrE$V" GlobalId="0r4uU0qWGHuO00025QrE$V" Name="UrinalType" Description="Selection of the type of urinal from the enumerated list of types where:-

Bowl: Individual wall mounted urinal.
Slab: Urinal that consists of a slab or sheet fixed to a wall and down which urinal flows into a floor channel.
Stall: Floor mounted urinal that consists of an elliptically shaped sanitary stall fixed to a wall and down which urine flows into a floor channel.
Trough: Wall mounted urinal of elongated rectangular shape on plan, that can be used by more than one person at a time." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_UrinalType">
						<EnumerationValues>
							<IfcLabel-wrapper>BOWL</IfcLabel-wrapper>
							<IfcLabel-wrapper>SLAB</IfcLabel-wrapper>
							<IfcLabel-wrapper>STALL</IfcLabel-wrapper>
							<IfcLabel-wrapper>TROUGH</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="UsagePurpose_1fZSkvX5HFxP0_mPJtSZjB" GlobalId="1fZSkvX5HFxP0_mPJtSZjB" Name="UsagePurpose" Description="The purpose of usage of the cess between rails, e.g. maintenance, rescue services." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_UsagePurpose">
						<EnumerationValues>
							<IfcLabel-wrapper>MAINTENANCE</IfcLabel-wrapper>
							<IfcLabel-wrapper>RESCUESERVICES</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="UsefulLength_3CH3oKGNr0XBmhsxbha8gU" GlobalId="3CH3oKGNr0XBmhsxbha8gU" Name="UsefulLength" Description="Length that can be used, generally length less overlap." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="UseInDiscrimination_0ba420qVmHuO00025QrE$V" GlobalId="0ba420qVmHuO00025QrE$V" Name="UseInDiscrimination" Description="An indication whether the time/current tripping information can be applied in a discrimination
analysis or not." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="UsePurpose_1iq$o0qWyHuO00025QrE$V" GlobalId="1iq$o0qWyHuO00025QrE$V" Name="UsePurpose" Description="The principal purpose for which the work surface is intended to be used e.g. writing/reading, computer, meeting, printer, reference files, etc." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="UserCapacity_2eXzZatEr5bOQ1ApLLVBvv" GlobalId="2eXzZatEr5bOQ1ApLLVBvv" Name="UserCapacity" Description="Indicates the user capacity of the device, defined as the maximum number of users that can be active at the same time." TemplateType="p_singlevalue" PrimaryMeasureType="IfcInteger" />
				<IfcSimplePropertyTemplate id="UserCorrectionFactor_3PfRv5G3bD8ejiLpHnvnyY" GlobalId="3PfRv5G3bD8ejiLpHnvnyY" Name="UserCorrectionFactor" Description="An arbitrary correction factor that may be applied by the user." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="UserDefinedBarSectionType_2THcLIk5195hSLwiZLCKs_" GlobalId="2THcLIk5195hSLwiZLCKs_" Name="UserDefinedBarSectionType" Description="User defined type of bar section type. Used when BarSectionType is set to USERDEFINED." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="UserDefinedBoltCrossSection_3PBwEzgljAuh8A3E6FbVJY" GlobalId="3PBwEzgljAuh8A3E6FbVJY" Name="UserDefinedBoltCrossSection" Description="Bolt cross section when _BoltCrossSection_ is set to USERDEFINED." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="UserDefinedBoltType_0cO6caU4DF3fMAqIlI6j4X" GlobalId="0cO6caU4DF3fMAqIlI6j4X" Name="UserDefinedBoltType" Description="Bolt type when _BoltType_ is set to USERDEFINED." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="UserDefinedExcavationMethod_1MCvrSjdH4FhcdbtYwrNpr" GlobalId="1MCvrSjdH4FhcdbtYwrNpr" Name="UserDefinedExcavationMethod" Description="Custom or specialized excavation methods beyond standard categories. Used when EarthworksCutExcavationMethod is set to USERDEFINED." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="UserDefinedGroutingType_3xklYq_Gr9_8Vj6GCEyJXC" GlobalId="3xklYq_Gr9_8Vj6GCEyJXC" Name="UserDefinedGroutingType" Description="A user defined grouting type for when _GroutingType_ is set to USERDEFINED." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="UserDefinedLRMType_3OPNP$6b9E0foQwDeAwOED" GlobalId="3OPNP$6b9E0foQwDeAwOED" Name="UserDefinedLRMType" Description="Gives the user defined type of this Linear Referencing Method when property _LRMType_ is _LRM_USERDEFINED_." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="UserDefinedPreSupportLocation_31L_rs0AXFXOUbPqj2c38J" GlobalId="31L_rs0AXFXOUbPqj2c38J" Name="UserDefinedPreSupportLocation" Description="Specifies a user defined pre-support location. Used when PreSupportLocation is set to USERDEFINED." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="UserDefinedPreSupportType_2OMwxuX_5ADwNa98rEikYK" GlobalId="2OMwxuX_5ADwNa98rEikYK" Name="UserDefinedPreSupportType" Description="Specifies a user defined type of pre-support applied. Used when PreSupporttype is set to USERDEFINED." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="UserDefinedPurpose_0ICrsHByL71B4Ri8aoiWbu" GlobalId="0ICrsHByL71B4Ri8aoiWbu" Name="UserDefinedPurpose" Description="Allows for specification of user specific purpose of the address beyond the enumeration values provided by Purpose attribute of type IfcAddressTypeEnum. When a value is provided for attribute UserDefinedPurpose, in parallel the attribute Purpose shall have enumeration value USERDEFINED." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="UserHistory_3ydee0qS0HuO00025QrE$V" GlobalId="3ydee0qS0HuO00025QrE$V" Name="UserHistory" Description="Indicates acknowledging user over time by identification corresponding to IfcPerson.Identification on an IfcActor." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcIdentifier" />
				<IfcSimplePropertyTemplate id="UserInterfaceType_2vSpfYCJv1kBISUSIgQtwO" GlobalId="2vSpfYCJv1kBISUSIgQtwO" Name="UserInterfaceType" Description="Indicates the user interface of the computer." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ComputerUIType">
						<EnumerationValues>
							<IfcLabel-wrapper>CLI</IfcLabel-wrapper>
							<IfcLabel-wrapper>GUI</IfcLabel-wrapper>
							<IfcLabel-wrapper>TOUCHSCREEN</IfcLabel-wrapper>
							<IfcLabel-wrapper>TOUCHTONE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="VacancyRateInCategoryFuture_3hf4U0qSKHuO00025QrE$V" GlobalId="3hf4U0qSKHuO00025QrE$V" Name="VacancyRateInCategoryFuture" Description="Percentage of vacancy found in the particular category expected in the future." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="VacancyRateInCategoryNow_3JpCE0qSKHuO00025QrE$V" GlobalId="3JpCE0qSKHuO00025QrE$V" Name="VacancyRateInCategoryNow" Description="Percentage of vacancy found in the particular category currently." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="ValidityPeriodDescription_3sTydqA0X1juk$nPEo2NdK" GlobalId="3sTydqA0X1juk$nPEo2NdK" Name="ValidityPeriodDescription" Description="A description of the validity period for the geo hazard. The description may be textual or encoded according to a standard referenced in _ValidityPeriodEncoding_
&gt;NOTE One possible validity period encoding is according to ISO14825:2011 (see e.g. https://xtour-eu-n.cloud.ptvgroup.com/manual/Content/Technical_concepts/DSC_gdf-timedomains.htm)" TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="ValidityPeriodEncoding_1vhiHkV1v0Afc8IcJjQGJd" GlobalId="1vhiHkV1v0Afc8IcJjQGJd" Name="ValidityPeriodEncoding" Description="Identifies the encoding standard used in property _ValidityPeriodDescription_ if any." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="Value_0jEF20qSuHuO00025QrE$V" GlobalId="0jEF20qSuHuO00025QrE$V" Name="Value" Description="The expected range and default value.

The default value such as normally-closed or normally-open." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="Value_1ZmZk0qSqHuO00025QrE$V" GlobalId="1ZmZk0qSqHuO00025QrE$V" Name="Value" Description="The expected range and default value.

The expected range and default value.  While the property data type is IfcReal (to support all cases including when the units are unknown), a unit may optionally be provided to indicate the measure and unit.  The LowerLimitValue and UpperLimitValue must fall within the physical Range and may be used to determine extents when charting Pset_ControllerPHistory.Value." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="Value_2GWqo0qUSHuO00025QrE$V" GlobalId="2GWqo0qUSHuO00025QrE$V" Name="Value" Description="The expected range and default value.

Indicates measured values over time which may be recorded continuously or only when changed beyond a particular deadband." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="Value_2Lqvs0qSqHuO00025QrE$V" GlobalId="2Lqvs0qSqHuO00025QrE$V" Name="Value" Description="The expected range and default value.

The expected range and default value.  The LowerLimitValue and UpperLimitValue must fall within the physical Range." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcInteger" />
				<IfcSimplePropertyTemplate id="Value_3LQQm0qWGHuO00025QrE$V" GlobalId="3LQQm0qWGHuO00025QrE$V" Name="Value" Description="The expected range and default value.

Indicates sensed values over time which may be recorded continuously or only when changed beyond a particular deadband. The range of possible values is defined by the SetPoint property of the corresponding sensor type property set." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="Value_3QNpa0qSqHuO00025QrE$V" GlobalId="3QNpa0qSqHuO00025QrE$V" Name="Value" Description="The expected range and default value.

The expected range and default value.  While the property data type is IfcReal (to support all cases including when the units are unknown), a unit may optionally be provided to indicate the measure and unit." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="ValueHistory_09mNO0qSqHuO00025QrE$V" GlobalId="09mNO0qSqHuO00025QrE$V" Name="ValueHistory" Description="Indicates values over time which may be recorded continuously or only when changed beyond a particular deadband. The range of possible values is defined by the Value property on the corresponding occurrence property set (Pset_ControllerTypeFloating, Pset_ControllerTypeProportional, Pset_ControllerTypeMultiPosition, or Pset_ControllerTypeTwoPosition)." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="ValveMechanism_1Hjxk0qXGHuO00025QrE$V" GlobalId="1Hjxk0qXGHuO00025QrE$V" Name="ValveMechanism" Description="The mechanism by which the valve function is achieved where:

BALL: Valve that has a ported ball that can be turned relative to the body seat ports.
BUTTERFLY: Valve in which a streamlined disc pivots about a diametric axis.
CONFIGUREDGATE: Screwdown valve in which the closing gate is shaped in a configured manner to have a more precise control of pressure and flow change across the valve.
GLAND: Valve with a tapered seating, in which a rotatable plug is retained by means of a gland and gland packing.
GLOBE: Screwdown valve that has a spherical body.
LUBRICATEDPLUG: Plug valve in which a lubricant is injected under pressure between the plug face and the body.
NEEDLE: Valve for regulating the flow in or from a pipe, in which a slender cone moves along the axis of flow to close against a fixed conical seat.
PARALLELSLIDE: Screwdown valve that has a machined plate that slides in formed grooves to form a seal.
PLUG: Valve that has a ported plug that can be turned relative to the body seat ports.
WEDGEGATE: Screwdown valve that has a wedge shaped plate fitting into tapered guides to form a seal." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ValveMechanism">
						<EnumerationValues>
							<IfcLabel-wrapper>BALL</IfcLabel-wrapper>
							<IfcLabel-wrapper>BUTTERFLY</IfcLabel-wrapper>
							<IfcLabel-wrapper>CONFIGUREDGATE</IfcLabel-wrapper>
							<IfcLabel-wrapper>GLAND</IfcLabel-wrapper>
							<IfcLabel-wrapper>GLOBE</IfcLabel-wrapper>
							<IfcLabel-wrapper>LUBRICATEDPLUG</IfcLabel-wrapper>
							<IfcLabel-wrapper>NEEDLE</IfcLabel-wrapper>
							<IfcLabel-wrapper>PARALLELSLIDE</IfcLabel-wrapper>
							<IfcLabel-wrapper>PLUG</IfcLabel-wrapper>
							<IfcLabel-wrapper>WEDGEGATE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ValveOperation_0u5dG0qXGHuO00025QrE$V" GlobalId="0u5dG0qXGHuO00025QrE$V" Name="ValveOperation" Description="The method of valve operation where:

DROPWEIGHT: A valve that is closed by the action of a weighted lever being released, the weight normally being prevented from dropping by being held by a wire, the closure normally being made by the action of heat on a fusible link in the wire
FLOAT: A valve that is opened and closed by the action of a float that rises and falls with water level. The float may be a ball attached to a lever or other mechanism
HYDRAULIC: A valve that is opened and closed by hydraulic actuation
LEVER: A valve that is opened and closed by the action of a lever rotating the gate within the valve.
LOCKSHIELD: A valve that requires the use of a special lockshield key for opening and closing, the operating mechanism being protected by a shroud during normal operation.
MOTORIZED: A valve that is opened and closed by the action of an electric motor on an actuator
PNEUMATIC: A valve that is opened and closed by pneumatic actuation
SOLENOID: A valve that is normally held open by a magnetic field in a coil acting on the gate but that is closed immediately if the electrical current generating the magnetic field is removed.
SPRING: A valve that is normally held in position by the pressure of a spring on a plate but that may be caused to open if the pressure of the fluid is sufficient to overcome the spring pressure.
THERMOSTATIC: A valve in which the ports are opened or closed to maintain a required predetermined temperature.
WHEEL: A valve that is opened and closed by the action of a wheel moving the gate within the valve." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ValveOperation">
						<EnumerationValues>
							<IfcLabel-wrapper>DROPWEIGHT</IfcLabel-wrapper>
							<IfcLabel-wrapper>FLOAT</IfcLabel-wrapper>
							<IfcLabel-wrapper>HYDRAULIC</IfcLabel-wrapper>
							<IfcLabel-wrapper>LEVER</IfcLabel-wrapper>
							<IfcLabel-wrapper>LOCKSHIELD</IfcLabel-wrapper>
							<IfcLabel-wrapper>MOTORIZED</IfcLabel-wrapper>
							<IfcLabel-wrapper>PNEUMATIC</IfcLabel-wrapper>
							<IfcLabel-wrapper>SOLENOID</IfcLabel-wrapper>
							<IfcLabel-wrapper>SPRING</IfcLabel-wrapper>
							<IfcLabel-wrapper>THERMOSTATIC</IfcLabel-wrapper>
							<IfcLabel-wrapper>WHEEL</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="ValvePattern_0d$fI0qXGHuO00025QrE$V" GlobalId="0d$fI0qXGHuO00025QrE$V" Name="ValvePattern" Description="The configuration of the ports of a valve according to either the linear route taken by a fluid flowing through the valve or by the number of ports where:

SINGLEPORT: Valve that has a single entry port from the system that it serves, the exit port being to the surrounding environment.
ANGLED_2_PORT: Valve in which the direction of flow is changed through 90 degrees.
STRAIGHT_2_PORT: Valve in which the flow is straight through.
STRAIGHT_3_PORT: Valve with three separate ports.
CROSSOVER_4_PORT: Valve with 4 separate ports." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_ValvePattern">
						<EnumerationValues>
							<IfcLabel-wrapper>SINGLEPORT</IfcLabel-wrapper>
							<IfcLabel-wrapper>ANGLED_2_PORT</IfcLabel-wrapper>
							<IfcLabel-wrapper>STRAIGHT_2_PORT</IfcLabel-wrapper>
							<IfcLabel-wrapper>STRAIGHT_3_PORT</IfcLabel-wrapper>
							<IfcLabel-wrapper>CROSSOVER_4_PORT</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="VaporPermeability_1d$b40qUqHuO00025QrE$V" GlobalId="1d$b40qUqHuO00025QrE$V" Name="VaporPermeability" Description="The rate of water vapor transmission per unit area per unit of vapor pressure differential under test conditions." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVaporPermeabilityMeasure" />
				<IfcSimplePropertyTemplate id="VaristorType_1hJWY0qVuHuO00025QrE$V" GlobalId="1hJWY0qVuHuO00025QrE$V" Name="VaristorType" Description="A list of the available types of varistor from which that required may be selected." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_VaristorType">
						<EnumerationValues>
							<IfcLabel-wrapper>METALOXIDE</IfcLabel-wrapper>
							<IfcLabel-wrapper>ZINCOXIDE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="VaultOffset_2UKv6rv1538Phe36azkgWO" GlobalId="2UKv6rv1538Phe36azkgWO" Name="VaultOffset" Description="Distance between parallel vaults." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="VehicleAvailability_09W2Dk$VDCIAO$YGHh$6_6" GlobalId="09W2Dk$VDCIAO$YGHh$6_6" Name="VehicleAvailability" Description="Vehicle or Plant availability" TemplateType="p_singlevalue" PrimaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="Veining_3h06n0RZX828Bq2sM4rpBg" GlobalId="3h06n0RZX828Bq2sM4rpBg" Name="Veining" Description="Description of observed vein structures related to hydrothermal alteration, mineralisation etc." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="Velocity_0cKuKOg$P7Mw5MBESnrvTU" GlobalId="0cKuKOg$P7Mw5MBESnrvTU" Name="Velocity" Description="The velocity of the fluid." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcLinearVelocityMeasure" />
				<IfcSimplePropertyTemplate id="Velocity_1$hsml_zP31BE8MHPk06nA" GlobalId="1$hsml_zP31BE8MHPk06nA" Name="Velocity" Description="The velocity of the fluid." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcLinearVelocityMeasure" />
				<IfcSimplePropertyTemplate id="VelocityFactorEnergy_10SRT1aMv5wwRi4vGIdEF3" GlobalId="10SRT1aMv5wwRi4vGIdEF3" Name="VelocityFactorEnergy" Description="Deviation in energy absorption performance due to strain rate" TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="VelocityFactorReaction_2GD9BPt$X6wBvT53fE9sI1" GlobalId="2GD9BPt$X6wBvT53fE9sI1" Name="VelocityFactorReaction" Description="Deviation in reaction due to strain rate" TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="VelocityHistory_20kOv3DPrDmhnl7ZnOP9ZX" GlobalId="20kOv3DPrDmhnl7ZnOP9ZX" Name="VelocityHistory" Description="The velocity of the fluid." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcLinearVelocityMeasure" />
				<IfcSimplePropertyTemplate id="VendingMachineUserInterface_2Zn17rWWTBGhHGhmLqk8UV" GlobalId="2Zn17rWWTBGhHGhmLqk8UV" Name="VendingMachineUserInterface" Description="Indicates the type of vending machine user interface." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_VendingMachineUserInterface">
						<EnumerationValues>
							<IfcLabel-wrapper>MOUSECHOOSETYPE</IfcLabel-wrapper>
							<IfcLabel-wrapper>TOUCHSCREEN</IfcLabel-wrapper>
							<IfcLabel-wrapper>TOUCH_TONE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="VentilatingPipeSize_1u_PC0qUeHuO00025QrE$V" GlobalId="1u_PC0qUeHuO00025QrE$V" Name="VentilatingPipeSize" Description="Size of the ventilating pipe(s)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="Ventilation_19pIo0qRuHuO00025QrE$V" GlobalId="19pIo0qRuHuO00025QrE$V" Name="Ventilation" Description="Required outside air ventilation." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="VentilationAirFlowrate_1FdIy0qWiHuO00025QrE$V" GlobalId="1FdIy0qWiHuO00025QrE$V" Name="VentilationAirFlowrate" Description="Ventilation outside air requirement for the space." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="VentilationAirFlowRateHistory_0kYGu0qWmHuO00025QrE$V" GlobalId="0kYGu0qWmHuO00025QrE$V" Name="VentilationAirFlowRateHistory" Description="Ventilation air flow rate in the space." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="VentilationDesignAirFlow_0l5KH$i7vDsewNRQpC1DUw" GlobalId="0l5KH$i7vDsewNRQpC1DUw" Name="VentilationDesignAirFlow" Description="Ventilation outside air requirement for the space." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="VentilationIndoorAir_272zk0qWiHuO00025QrE$V" GlobalId="272zk0qWiHuO00025QrE$V" Name="VentilationIndoorAir" Description="Ventilation loads from indoor air." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="VentilationIndoorAirHistory_002pC0qWmHuO00025QrE$V" GlobalId="002pC0qWmHuO00025QrE$V" Name="VentilationIndoorAirHistory" Description="Ventilation loads from indoor air." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="VentilationOutdoorAir_2FP1Q0qWiHuO00025QrE$V" GlobalId="2FP1Q0qWiHuO00025QrE$V" Name="VentilationOutdoorAir" Description="Ventilation loads from outdoor air." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="VentilationOutdoorAirHistory_031YE0qWmHuO00025QrE$V" GlobalId="031YE0qWmHuO00025QrE$V" Name="VentilationOutdoorAirHistory" Description="Ventilation loads from outdoor air." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPowerMeasure" />
				<IfcSimplePropertyTemplate id="VersionNumber_05P2$JUujC9AsIOpln0NTr" GlobalId="05P2$JUujC9AsIOpln0NTr" Name="VersionNumber" Description="Version tag of the model regarding its descriptive informations." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="VerticalBarPitch_3McDe0qW0HuO00025QrE$V" GlobalId="3McDe0qW0HuO00025QrE$V" Name="VerticalBarPitch" Description="The pitch length of the vertical bar." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="VerticalBoreholeSpacing_23Yy5aOIfFZwpwj5Oj4J3v" GlobalId="23Yy5aOIfFZwpwj5Oj4J3v" Name="VerticalBoreholeSpacing" Description="Vertical spacing between boreholes." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="VerticalOrthogonality_2YlbHbk1D2r9MQG8$pVBmR" GlobalId="2YlbHbk1D2r9MQG8$pVBmR" Name="VerticalOrthogonality" Description="Indicative (95%-100%) range orthogonality associated to the vertical shape and orientation in Z, if different to the overall orthogonality." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="VerticalSpacing_0bD2dVmzLCt9$vqBHrS5Ib" GlobalId="0bD2dVmzLCt9$vqBHrS5Ib" Name="VerticalSpacing" Description="Vertical spacing of bolts." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="VerticalSpacing_2mV3M0qX8HuO00025QrE$V" GlobalId="2mV3M0qX8HuO00025QrE$V" Name="VerticalSpacing" Description="Vertical spacing between tubes in the tube bundle." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="VerticalStraightness_1bHjGtr3j7MveQ70Lzosub" GlobalId="1bHjGtr3j7MveQ70Lzosub" Name="VerticalStraightness" Description="Indicative (95%-100%) range straightness associated to the vertical shape in Z, if different to the overall straightness." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="VerticalTolerance_2M1e8BS3PBPPQBW9Q2nF$P" GlobalId="2M1e8BS3PBPPQBW9Q2nF$P" Name="VerticalTolerance" Description="Indicative (95%-100%) range tolerance associated to the vertical shape and position in Z, if different to the overall tolerance." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="VerticalUncertainty_3pJ9ffcd5D3fYZdbK3HYls" GlobalId="3pJ9ffcd5D3fYZdbK3HYls" Name="VerticalUncertainty" Description="Indicative (95%-100%) range diameter associated to the vertical shape and position in Z, if different to the linear uncertainty." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="VesselDepth_1XDZu1a5f32R9ecKDd56ze" GlobalId="1XDZu1a5f32R9ecKDd56ze" Name="VesselDepth" Description="Depth of the vessel from the main deck to the keel." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="VesselDraft_1$K81vvzf2buienp$q3rxV" GlobalId="1$K81vvzf2buienp$q3rxV" Name="VesselDraft" Description="Depth of vessel from the waterline to the keel (LightShip, Ballasted, Maximum)" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="VibrationTransmissibility_1$KJI0qXKHuO00025QrE$V" GlobalId="1$KJI0qXKHuO00025QrE$V" Name="VibrationTransmissibility" Description="The vibration transmissibility percentage." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="VideoCaptionMode_1Krek0qSCHuO00025QrE$V" GlobalId="1Krek0qSCHuO00025QrE$V" Name="VideoCaptionMode" Description="Indicates video closed captioning modes." TemplateType="p_tablevalue" PrimaryMeasureType="IfcIdentifier" SecondaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="VideoCaptionMode_3jkDS0qS8HuO00025QrE$V" GlobalId="3jkDS0qS8HuO00025QrE$V" Name="VideoCaptionMode" Description="Indicates video closed captioning modes." TemplateType="p_tablevalue" PrimaryMeasureType="IfcIdentifier" SecondaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="VideoCaptureInterval_0bSqy0qS8HuO00025QrE$V" GlobalId="0bSqy0qS8HuO00025QrE$V" Name="VideoCaptureInterval" Description="Indicates video frame capture time intervals." TemplateType="p_tablevalue" PrimaryMeasureType="IfcIdentifier" SecondaryMeasureType="IfcTimeMeasure" />
				<IfcSimplePropertyTemplate id="VideoResolutionHeight_0OxlQ0qS8HuO00025QrE$V" GlobalId="0OxlQ0qS8HuO00025QrE$V" Name="VideoResolutionHeight" Description="Indicates the number of vertical pixels (the largest native video resolution height)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcInteger" />
				<IfcSimplePropertyTemplate id="VideoResolutionHeight_0wdAs0qSCHuO00025QrE$V" GlobalId="0wdAs0qSCHuO00025QrE$V" Name="VideoResolutionHeight" Description="Indicates the number of vertical pixels (the largest native video resolution height)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcInteger" />
				<IfcSimplePropertyTemplate id="VideoResolutionHeight_3IvcA0qS8HuO00025QrE$V" GlobalId="3IvcA0qS8HuO00025QrE$V" Name="VideoResolutionHeight" Description="Indicates the number of vertical pixels (the largest native video resolution height)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcInteger" />
				<IfcSimplePropertyTemplate id="VideoResolutionMode_0UJ440qS8HuO00025QrE$V" GlobalId="0UJ440qS8HuO00025QrE$V" Name="VideoResolutionMode" Description="Indicates video resolution modes." TemplateType="p_tablevalue" PrimaryMeasureType="IfcIdentifier" SecondaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="VideoResolutionMode_11AoK0qSCHuO00025QrE$V" GlobalId="11AoK0qSCHuO00025QrE$V" Name="VideoResolutionMode" Description="Indicates video resolution modes." TemplateType="p_tablevalue" PrimaryMeasureType="IfcIdentifier" SecondaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="VideoResolutionMode_3Q3N20qS8HuO00025QrE$V" GlobalId="3Q3N20qS8HuO00025QrE$V" Name="VideoResolutionMode" Description="Indicates video resolution modes." TemplateType="p_tablevalue" PrimaryMeasureType="IfcIdentifier" SecondaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="VideoResolutionWidth_0JaQm0qS8HuO00025QrE$V" GlobalId="0JaQm0qS8HuO00025QrE$V" Name="VideoResolutionWidth" Description="Indicates the number of horizontal pixels (the largest native video resolution width)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcInteger" />
				<IfcSimplePropertyTemplate id="VideoResolutionWidth_0qfio0qSCHuO00025QrE$V" GlobalId="0qfio0qSCHuO00025QrE$V" Name="VideoResolutionWidth" Description="Indicates the number of horizontal pixels (the largest native video resolution width)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcInteger" />
				<IfcSimplePropertyTemplate id="VideoResolutionWidth_3BlrI0qS8HuO00025QrE$V" GlobalId="3BlrI0qS8HuO00025QrE$V" Name="VideoResolutionWidth" Description="Indicates the number of horizontal pixels (the largest native video resolution width)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcInteger" />
				<IfcSimplePropertyTemplate id="VideoScaleMode_1BJIE0qSCHuO00025QrE$V" GlobalId="1BJIE0qSCHuO00025QrE$V" Name="VideoScaleMode" Description="Indicates video scaling modes." TemplateType="p_tablevalue" PrimaryMeasureType="IfcIdentifier" SecondaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="VideoScaleMode_3aBsy0qS8HuO00025QrE$V" GlobalId="3aBsy0qS8HuO00025QrE$V" Name="VideoScaleMode" Description="Indicates video scaling modes." TemplateType="p_tablevalue" PrimaryMeasureType="IfcIdentifier" SecondaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="ViscosityTemperatureDerivative_0IAQa0qUqHuO00025QrE$V" GlobalId="0IAQa0qUqHuO00025QrE$V" Name="ViscosityTemperatureDerivative" Description="Viscosity temperature derivative." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="VisibleAngleLeft_17k9q0qS4HuO00025QrE$V" GlobalId="17k9q0qS4HuO00025QrE$V" Name="VisibleAngleLeft" Description="Angle of visibility to the left of the access." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositivePlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="VisibleAngleRight_1D5UU0qS4HuO00025QrE$V" GlobalId="1D5UU0qS4HuO00025QrE$V" Name="VisibleAngleRight" Description="Angle of visibility to the right of the access." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositivePlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="VisibleLightReflectance_1wS8w0qTqHuO00025QrE$V" GlobalId="1wS8w0qTqHuO00025QrE$V" Name="VisibleLightReflectance" Description="Fraction of the visible light that is reflected by the glazing at normal incidence. It is a value without unit." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="VisibleLightReflectance_2SVmQ0qWSHuO00025QrE$V" GlobalId="2SVmQ0qWSHuO00025QrE$V" Name="VisibleLightReflectance" Description="Fraction of the visible light that is reflected by the glazing at normal incidence. It is a value without unit." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="VisibleLightTransmittance_1$IZW0qWSHuO00025QrE$V" GlobalId="1$IZW0qWSHuO00025QrE$V" Name="VisibleLightTransmittance" Description="Fraction of the visible light that passes the object at normal incidence. It is a value without unit." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="VisibleLightTransmittance_20Pc_0qTqHuO00025QrE$V" GlobalId="20Pc_0qTqHuO00025QrE$V" Name="VisibleLightTransmittance" Description="Fraction of the visible light that passes the object at normal incidence. It is a value without unit." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="VisibleReflectanceBack_2tH860qUqHuO00025QrE$V" GlobalId="2tH860qUqHuO00025QrE$V" Name="VisibleReflectanceBack" Description="Reflectance at normal incidence (visible): back side. Defines the fraction of the solar ray in the visible spectrum that is reflected and not transmitted when the ray passes from one medium into another, at the &quot;back&quot; side of the other material, perpendicular to the surface. Dependent on material and surface characteristics." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="VisibleReflectanceFront_2zEcA0qUqHuO00025QrE$V" GlobalId="2zEcA0qUqHuO00025QrE$V" Name="VisibleReflectanceFront" Description="Reflectance at normal incidence (visible): front side. Defines the fraction of the solar ray in the visible spectrum that is reflected and not transmitted when the ray passes from one medium into another, at the &quot;front&quot; side of the other material, perpendicular to the surface. Dependent on material and surface characteristics." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="VisibleRefractionIndex_0eq000qUqHuO00025QrE$V" GlobalId="0eq000qUqHuO00025QrE$V" Name="VisibleRefractionIndex" Description="Index of refraction (visible) defines the &quot;bending&quot; of the sola! r ray in the visible spectrum when it passes from one medium into another." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="VisibleTransmittance_2LIly0qUqHuO00025QrE$V" GlobalId="2LIly0qUqHuO00025QrE$V" Name="VisibleTransmittance" Description="Transmittance at normal incidence (visible). Defines the fraction of the visible spectrum of solar radiation that passes through per unit area, perpendicular to the surface." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="VoidRatio_3iyX_eZCr9MgXBX7IpP$HN" GlobalId="3iyX_eZCr9MgXBX7IpP$HN" Name="VoidRatio" Description="Ratio of the volume of void to the volume of solid." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="VoidShape_1H0k$LSmzANucAEmnKbfql" GlobalId="1H0k$LSmzANucAEmnKbfql" Name="VoidShape" Description="The shape form of the provision for void, the minimum set of agreed values includes &apos;Rectangle&apos;, &apos;Round&apos;, and &apos;Undefined&apos;." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="Voltage_27j$QobBL4UhVjgWuhQGvz" GlobalId="27j$QobBL4UhVjgWuhQGvz" Name="Voltage" Description="The actual voltage and operable range." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcElectricVoltageMeasure" />
				<IfcSimplePropertyTemplate id="VoltageHistory_1lg7CDGrH2v9TIUzdU$h17" GlobalId="1lg7CDGrH2v9TIUzdU$h17" Name="VoltageHistory" Description="Log of electrical voltage." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcElectricVoltageMeasure" />
				<IfcSimplePropertyTemplate id="VoltageLevel_0jKEI0qVuHuO00025QrE$V" GlobalId="0jKEI0qVuHuO00025QrE$V" Name="VoltageLevel" Description="The voltage levels for which the data of the instance is valid. More than one value may be selected in the enumeration." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" id="i3756" Name="PEnum_VoltageLevels">
						<EnumerationValues>
							<IfcLabel-wrapper>U230</IfcLabel-wrapper>
							<IfcLabel-wrapper>U400</IfcLabel-wrapper>
							<IfcLabel-wrapper>U440</IfcLabel-wrapper>
							<IfcLabel-wrapper>U525</IfcLabel-wrapper>
							<IfcLabel-wrapper>U690</IfcLabel-wrapper>
							<IfcLabel-wrapper>U1000</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="VoltageLevel_0YuXi0qVqHuO00025QrE$V" GlobalId="0YuXi0qVqHuO00025QrE$V" Name="VoltageLevel" Description="The voltage levels for which the data of the instance is valid. More than one value may be selected in the enumeration." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i3756" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="VoltageLevel_0z6Ve0qVaHuO00025QrE$V" GlobalId="0z6Ve0qVaHuO00025QrE$V" Name="VoltageLevel" Description="The voltage levels for which the data of the instance is valid. More than one value may be selected in the enumeration." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i3756" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="VoltageLevel_2EmeI0qVaHuO00025QrE$V" GlobalId="2EmeI0qVaHuO00025QrE$V" Name="VoltageLevel" Description="The voltage levels for which the data of the instance is valid. More than one value may be selected in the enumeration." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i3756" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="VoltageLevel_2sPHq0qVWHuO00025QrE$V" GlobalId="2sPHq0qVWHuO00025QrE$V" Name="VoltageLevel" Description="The voltage levels for which the data of the instance is valid. More than one value may be selected in the enumeration." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i3756" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="VoltageLevel_3ixsU0qVaHuO00025QrE$V" GlobalId="3ixsU0qVaHuO00025QrE$V" Name="VoltageLevel" Description="The voltage levels for which the data of the instance is valid. More than one value may be selected in the enumeration." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i3756" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="VoltageLevel_3tNJ60qVWHuO00025QrE$V" GlobalId="3tNJ60qVWHuO00025QrE$V" Name="VoltageLevel" Description="The voltage levels for which the data of the instance is valid. More than one value may be selected in the enumeration." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i3756" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="VoltageRegulationRate_2JurpF5$z9eRwfdnERHveS" GlobalId="2JurpF5$z9eRwfdnERHveS" Name="VoltageRegulationRate" Description="When the input side voltage changes from the lowest allowable input value to the specified maximum value, the relative change value of the output voltage is the percentage of the rated output voltage." TemplateType="p_singlevalue" PrimaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="Volume_299MY0qX8HuO00025QrE$V" GlobalId="299MY0qX8HuO00025QrE$V" Name="Volume" Description="Volume of the element.

Total volume of fluid in the tubes and their headers." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumeMeasure" />
				<IfcSimplePropertyTemplate id="VolumetricCapacity_0dBcQhjmvDyAJkVkwc0QxW" GlobalId="0dBcQhjmvDyAJkVkwc0QxW" Name="VolumetricCapacity" Description="Capacity of Trench/Sump." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumeMeasure" />
				<IfcSimplePropertyTemplate id="VolumetricEfficiency_3aCsq0qSeHuO00025QrE$V" GlobalId="3aCsq0qSeHuO00025QrE$V" Name="VolumetricEfficiency" Description="Ratio of the actual volume of gas entering the compressor to the theoretical displacement of the compressor." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="VolumetricFlowRate_1Zd01dwqHEsBdHToHy7np2" GlobalId="1Zd01dwqHEsBdHToHy7np2" Name="VolumetricFlowRate" Description="The volumetric flow rate of the fluid." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="VolumetricFlowRate_2q9IxoM5X6NOGEDJdRVkrU" GlobalId="2q9IxoM5X6NOGEDJdRVkrU" Name="VolumetricFlowRate" Description="The volumetric flow rate of the fluid." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="VolumetricFlowRateHistory_1_ZeVmL9X3mAEUYAm$5rnk" GlobalId="1_ZeVmL9X3mAEUYAm$5rnk" Name="VolumetricFlowRateHistory" Description="The volumetric flow rate of the fluid." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="WaistThickness_17ibcdsn96z8VizWIKOSnI" GlobalId="17ibcdsn96z8VizWIKOSnI" Name="WaistThickness" Description="Minimum thickness of the stair flight, measured perpendicular to the slope of the flight to the inner corner of riser and tread. It is a pre-calculated value, in case of inconsistencies, the value derived from the shape representation shall take precedence." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="WaistThickness_2KASe0qWqHuO00025QrE$V" GlobalId="2KASe0qWqHuO00025QrE$V" Name="WaistThickness" Description="Minimum thickness of the stair flight, measured perpendicular to the slope of the flight to the inner corner of riser and tread. It is a pre-calculated value, in case of inconsistencies, the value derived from the shape representation shall take precedence." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="WalkingLineOffset_1nbx40qWqHuO00025QrE$V" GlobalId="1nbx40qWqHuO00025QrE$V" Name="WalkingLineOffset" Description="Offset of the walking line from the inner side of the flight.
Note: the walking line may have a own shape representation (in case of inconsistencies, the value derived from the shape representation shall take precedence)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="WalkingLineOffset_2NNvZYNiXEJQrIeliihHby" GlobalId="2NNvZYNiXEJQrIeliihHby" Name="WalkingLineOffset" Description="Offset of the walking line from the inner side of the flight.
Note: the walking line may have a own shape representation (in case of inconsistencies, the value derived from the shape representation shall take precedence)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="WallCovering_1f6Jf$P7z59hr$7JkVtHgU" GlobalId="1f6Jf$P7z59hr$7JkVtHgU" Name="WallCovering" Description="Label to indicate the material or finish of the space cladding. The label is used for room book information and often displayed in room stamp.The material information is provided in absence of an IfcCovering (type=CLADDING) object with own shape representation and material assignment. In case of inconsistency the material assigned to IfcCovering elements takes precedence." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="WallCoveringThickness_14ntMnIWr6nOhOn_DiDAD9" GlobalId="14ntMnIWr6nOhOn_DiDAD9" Name="WallCoveringThickness" Description="Thickness of the material layer(s) for the space cladding.The thickness information is provided in absence of an IfcCovering (type=CLADDING) object with own shape representation. In cases of inconsistency between the geometric parameters of an assigned IfcCovering and this attached property, the geometric parameters take precedence." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="WallMaterial_0186u0qTGHuO00025QrE$V" GlobalId="0186u0qTGHuO00025QrE$V" Name="WallMaterial" Description="The material from which the wall of the chamber is constructed.
NOTE: It is assumed that chamber walls will be constructed of a single material." TemplateType="p_referencevalue" PrimaryMeasureType="IfcMaterialDefinition" />
				<IfcSimplePropertyTemplate id="WallMaterial_18fle0qTGHuO00025QrE$V" GlobalId="18fle0qTGHuO00025QrE$V" Name="WallMaterial" Description="The material from which the wall of the chamber is constructed.
NOTE: It is assumed that chamber walls will be constructed of a single material." TemplateType="p_referencevalue" PrimaryMeasureType="IfcMaterialDefinition" />
				<IfcSimplePropertyTemplate id="WallMaterial_2eKDM0qTCHuO00025QrE$V" GlobalId="2eKDM0qTCHuO00025QrE$V" Name="WallMaterial" Description="The material from which the wall of the chamber is constructed.
NOTE: It is assumed that chamber walls will be constructed of a single material." TemplateType="p_referencevalue" PrimaryMeasureType="IfcMaterialDefinition" />
				<IfcSimplePropertyTemplate id="WallMaterial_2Y3oa0qTGHuO00025QrE$V" GlobalId="2Y3oa0qTGHuO00025QrE$V" Name="WallMaterial" Description="The material from which the wall of the chamber is constructed.
NOTE: It is assumed that chamber walls will be constructed of a single material." TemplateType="p_referencevalue" PrimaryMeasureType="IfcMaterialDefinition" />
				<IfcSimplePropertyTemplate id="WallThickness_1_bww0qTCHuO00025QrE$V" GlobalId="1_bww0qTCHuO00025QrE$V" Name="WallThickness" Description="The thickness of the wall construction.
NOTE: It is assumed that walls will be constructed at a single thickness." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="WarpingConstant_35usQ0qVOHuO00025QrE$V" GlobalId="35usQ0qVOHuO00025QrE$V" Name="WarpingConstant" Description="Warping constant of the profile for torsional action. For example measured in mm6." TemplateType="p_singlevalue" PrimaryMeasureType="IfcWarpingConstantMeasure" />
				<IfcSimplePropertyTemplate id="WarrantyContent_0gOUu0qXOHuO00025QrE$V" GlobalId="0gOUu0qXOHuO00025QrE$V" Name="WarrantyContent" Description="The content of the warranty." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="WarrantyIdentifier_08Q6k0qXOHuO00025QrE$V" GlobalId="08Q6k0qXOHuO00025QrE$V" Name="WarrantyIdentifier" Description="The identifier assigned to a warranty." TemplateType="p_singlevalue" PrimaryMeasureType="IfcIdentifier" />
				<IfcSimplePropertyTemplate id="WarrantyPeriod_0Ws8O0qXOHuO00025QrE$V" GlobalId="0Ws8O0qXOHuO00025QrE$V" Name="WarrantyPeriod" Description="The time duration during which a manufacturer or supplier guarantees or warrants the performance of an artefact." TemplateType="p_singlevalue" PrimaryMeasureType="IfcDuration" />
				<IfcSimplePropertyTemplate id="WarrantyStartDate_0EzkC0qXOHuO00025QrE$V" GlobalId="0EzkC0qXOHuO00025QrE$V" Name="WarrantyStartDate" Description="The date on which the warranty commences." TemplateType="p_singlevalue" PrimaryMeasureType="IfcDate" />
				<IfcSimplePropertyTemplate id="WashersCount_3wL2G0qV0HuO00025QrE$V" GlobalId="3wL2G0qV0HuO00025QrE$V" Name="WashersCount" Description="Count of washers to be mounted on one bolt" TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="WasherShape_0TVjE0qV4HuO00025QrE$V" GlobalId="0TVjE0qV4HuO00025QrE$V" Name="WasherShape" Description="Shape of the washers, e.g. &apos;Standard&apos;, &apos;Square&apos;" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="WashHandBasinType_20BPg0qWGHuO00025QrE$V" GlobalId="20BPg0qWGHuO00025QrE$V" Name="WashHandBasinType" Description="Defines the types of wash hand basin that may be specified where:

DentalCuspidor: Waste water appliance that receives and flushes away mouth washings
.
HandRinse: Wall mounted wash hand basin that has an overall width of 500mm or less
.
Hospital: Wash hand basin that has a smooth easy clean surface without tapholes or overflow slot for use where hygiene is of prime importance.

Tipup: Wash hand basin mounted on pivots so that it can be emptied by tilting.

Vanity: Wash hand basin for installation into a horizontal surface.

Washfountain: Wash hand basin that is circular, semi-circular or polygonal on plan, at which more than one person can wash at the same time.
WashingTrough: Wash hand basin of elongated rectangular shape in plan, at which more than one person can wash at the same time." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_WashHandBasinType">
						<EnumerationValues>
							<IfcLabel-wrapper>DENTALCUSPIDOR</IfcLabel-wrapper>
							<IfcLabel-wrapper>HANDRINSE</IfcLabel-wrapper>
							<IfcLabel-wrapper>HOSPITAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>TIPUP</IfcLabel-wrapper>
							<IfcLabel-wrapper>WASHFOUNTAIN</IfcLabel-wrapper>
							<IfcLabel-wrapper>WASHINGTROUGH</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="WasteTrapType_23ono0qXWHuO00025QrE$V" GlobalId="23ono0qXWHuO00025QrE$V" Name="WasteTrapType" Description="Identifies the predefined types of trap from which the type required may be set." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" xsi:nil="true" href="i3566" />
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Water_3ql0M0qXCHuO00025QrE$V" GlobalId="3ql0M0qXCHuO00025QrE$V" Name="Water" Description="The amount of water consumed during the period specified in the time series." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcVolumeMeasure" />
				<IfcSimplePropertyTemplate id="WaterConsumption_09VwM0qU8HuO00025QrE$V" GlobalId="09VwM0qU8HuO00025QrE$V" Name="WaterConsumption" Description="Quantity of water used." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumeMeasure" />
				<IfcSimplePropertyTemplate id="WaterConsumptionPerUnit_2p4cS0qU4HuO00025QrE$V" GlobalId="2p4cS0qU4HuO00025QrE$V" Name="WaterConsumptionPerUnit" Description="Quantity of water used." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumeMeasure" />
				<IfcSimplePropertyTemplate id="WaterContent_1xZFTftuz7KOGWUAYf0RKn" GlobalId="1xZFTftuz7KOGWUAYf0RKn" Name="WaterContent" Description="The ratio of weight of water Ww to the weight of solids (Ws or Wd) in a given mass of soil or rock." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="WaterContent_2fKIc0qWeHuO00025QrE$V" GlobalId="2fKIc0qWeHuO00025QrE$V" Name="WaterContent" Description="Weight of water content within the heater." TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassMeasure" />
				<IfcSimplePropertyTemplate id="WaterContent_2wZL3Anx93bBPkmx7Acxjd" GlobalId="2wZL3Anx93bBPkmx7Acxjd" Name="WaterContent" Description="Ratio of the mass of water to the mass of solids." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="WaterDeliverySystemType_1Q07jhdBbBTg0$YC_3U_JM" GlobalId="1Q07jhdBbBTg0$YC_3U_JM" Name="WaterDeliverySystemType" Description="Type of water delivery system" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="WaterDeliveryValveType_389nXpsIbAVvQpQ2vnIlSG" GlobalId="389nXpsIbAVvQpQ2vnIlSG" Name="WaterDeliveryValveType" Description="Type of water delivery valve" TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="WaterFilterType_0r18y0qUOHuO00025QrE$V" GlobalId="0r18y0qUOHuO00025QrE$V" Name="WaterFilterType" Description="Further qualifies the type of water filter. Filtration removes undissolved matter; Purification removes dissolved matter; Softening replaces dissolved matter." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_FilterWaterFilterType">
						<EnumerationValues>
							<IfcLabel-wrapper>FILTRATION_DIATOMACEOUSEARTH</IfcLabel-wrapper>
							<IfcLabel-wrapper>FILTRATION_SAND</IfcLabel-wrapper>
							<IfcLabel-wrapper>PURIFICATION_DEIONIZING</IfcLabel-wrapper>
							<IfcLabel-wrapper>PURIFICATION_REVERSEOSMOSIS</IfcLabel-wrapper>
							<IfcLabel-wrapper>SOFTENING_ZEOLITE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="WaterFlowControlSystemType_35Dje0qSuHuO00025QrE$V" GlobalId="35Dje0qSuHuO00025QrE$V" Name="WaterFlowControlSystemType" Description="Factory fitted waterflow control system." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_CooledBeamWaterFlowControlSystemType">
						<EnumerationValues>
							<IfcLabel-wrapper>NONE</IfcLabel-wrapper>
							<IfcLabel-wrapper>ONOFFVALVE</IfcLabel-wrapper>
							<IfcLabel-wrapper>2WAYVALVE</IfcLabel-wrapper>
							<IfcLabel-wrapper>3WAYVALVE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="WaterFoulingResistance_24rbo0qSmHuO00025QrE$V" GlobalId="24rbo0qSmHuO00025QrE$V" Name="WaterFoulingResistance" Description="Fouling resistance on water/air side." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcThermalResistanceMeasure" />
				<IfcSimplePropertyTemplate id="WaterFoulingResistance_3y5ki0qU8HuO00025QrE$V" GlobalId="3y5ki0qU8HuO00025QrE$V" Name="WaterFoulingResistance" Description="Fouling resistance on water/air side." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcThermalResistanceMeasure" />
				<IfcSimplePropertyTemplate id="WaterImpermeability_01UJC0qUqHuO00025QrE$V" GlobalId="01UJC0qUqHuO00025QrE$V" Name="WaterImpermeability" Description="Description of the water impermeability denoting the water repelling properties." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="WaterInletTemperatureRange_2Ez5q0qSGHuO00025QrE$V" GlobalId="2Ez5q0qSGHuO00025QrE$V" Name="WaterInletTemperatureRange" Description="Allowable water inlet temperature range." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="WaterIsPotable_2m$jS0qUOHuO00025QrE$V" GlobalId="2m$jS0qUOHuO00025QrE$V" Name="WaterIsPotable" Description="Indication of whether the water flow from the hydrant is potable (set TRUE) or non potable (set FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="WaterLeakage_0nA2qw75z08e_duxVyg0IJ" GlobalId="0nA2qw75z08e_duxVyg0IJ" Name="WaterLeakage" Description="Degree of water leakage estimated from water flow information." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="WaterLevel_1q98Z7TRf7bP3iVW84ueQW" GlobalId="1q98Z7TRf7bP3iVW84ueQW" Name="WaterLevel" Description="Measured distance to water level in borehole from ground surface." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLengthMeasure" />
				<IfcSimplePropertyTemplate id="WaterPressDropCurve_2yw9e0qU8HuO00025QrE$V" GlobalId="2yw9e0qU8HuO00025QrE$V" Name="WaterPressDropCurve" Description="Water pressure drop as function of water flow rate." TemplateType="p_tablevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" SecondaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="WaterPressure_2kPNEvWOXCOx0LkHjz9Xi$" GlobalId="2kPNEvWOXCOx0LkHjz9Xi$" Name="WaterPressure" Description="Water pressure of nozzle." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="WaterPressureDropCurve_0l0BK0qSeHuO00025QrE$V" GlobalId="0l0BK0qSeHuO00025QrE$V" Name="WaterPressureDropCurve" Description="Water pressure drop curve, pressure drop – flow rate curve, WaterPressureDrop = f(WaterflowRate)." TemplateType="p_tablevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" SecondaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="WaterPressureDropCurves_1JzoS0qSuHuO00025QrE$V" GlobalId="1JzoS0qSuHuO00025QrE$V" Name="WaterPressureDropCurves" Description="Water pressure drop as function of water flow rate." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="WaterPressureRange_3LJhc0qSuHuO00025QrE$V" GlobalId="3LJhc0qSuHuO00025QrE$V" Name="WaterPressureRange" Description="Allowable water circuit working pressure range." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="WaterproofingSystem_3$algbaZDFJPwTAD8YkBcA" GlobalId="3$algbaZDFJPwTAD8YkBcA" Name="WaterproofingSystem" Description="Indicates the type of waterproofing system." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_WaterproofingSystem">
						<EnumerationValues>
							<IfcLabel-wrapper>WATERTIGHT</IfcLabel-wrapper>
							<IfcLabel-wrapper>DRAINED</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="WaterRequirement_2Y5YM0qU8HuO00025QrE$V" GlobalId="2Y5YM0qU8HuO00025QrE$V" Name="WaterRequirement" Description="Make-up water requirement." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="WaterRequirement_3WLXc0qSyHuO00025QrE$V" GlobalId="3WLXc0qSyHuO00025QrE$V" Name="WaterRequirement" Description="Make-up water requirement." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="WaterRequirement_3y$qi0qUaHuO00025QrE$V" GlobalId="3y$qi0qUaHuO00025QrE$V" Name="WaterRequirement" Description="Make-up water requirement." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumetricFlowRateMeasure" />
				<IfcSimplePropertyTemplate id="WaterStorageCapacity_2KKQU0qSGHuO00025QrE$V" GlobalId="2KKQU0qSGHuO00025QrE$V" Name="WaterStorageCapacity" Description="Water storage capacity." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumeMeasure" />
				<IfcSimplePropertyTemplate id="WaterSumpTemperature_1OBJ_0qU8HuO00025QrE$V" GlobalId="1OBJ_0qU8HuO00025QrE$V" Name="WaterSumpTemperature" Description="Water sump temperature." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="WatertightnessClassification_3o5MfIEcL6VubC3CVWfHTs" GlobalId="3o5MfIEcL6VubC3CVWfHTs" Name="WatertightnessClassification" Description="Specifies the watertightness classification." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="WaterTightnessRating_1GCF129DbCTAkdKob1SB8d" GlobalId="1GCF129DbCTAkdKob1SB8d" Name="WaterTightnessRating" Description="Water tightness rating for this object.
It is provided according to the national building code." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="WaterTightnessRating_3f9JFpf_H1OPQjaZ_kufwM" GlobalId="3f9JFpf_H1OPQjaZ_kufwM" Name="WaterTightnessRating" Description="Water tightness rating for this object.
It is provided according to the national building code." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="WaterVolume_2JzgU4s2TF4e6fts$U63bp" GlobalId="2JzgU4s2TF4e6fts$U63bp" Name="WaterVolume" Description="Relative volume of water stratum constituents." TemplateType="p_singlevalue" PrimaryMeasureType="IfcVolumeMeasure" />
				<IfcSimplePropertyTemplate id="WaveLoading_3ixoBF$s5EUxf3ONHSALX6" GlobalId="3ixoBF$s5EUxf3ONHSALX6" Name="WaveLoading" Description="Wave loading force" TemplateType="p_singlevalue" PrimaryMeasureType="IfcForceMeasure" />
				<IfcSimplePropertyTemplate id="WaveRange_3YT7H981H8GBd3yxDEZVD_" GlobalId="3YT7H981H8GBd3yxDEZVD_" Name="WaveRange" Description="Indicative (95%-100%) range between peaks and troughs of waves" TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="WeatherConditions_0xXHu3ITj3DPV0alWk63er" GlobalId="0xXHu3ITj3DPV0alWk63er" Name="WeatherConditions" Description="Indicates the weather conditions during the application of the course" TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="WeatherDataDate_0ORbG0qV8HuO00025QrE$V" GlobalId="0ORbG0qV8HuO00025QrE$V" Name="WeatherDataDate" Description="The date for which the weather data was gathered." TemplateType="p_singlevalue" PrimaryMeasureType="IfcDateTime" />
				<IfcSimplePropertyTemplate id="WeatherDataStation_0J4Gc0qV8HuO00025QrE$V" GlobalId="0J4Gc0qV8HuO00025QrE$V" Name="WeatherDataStation" Description="The site weather data station description or reference to the data source from which weather data was obtained for use in calculations." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="WeatherDowntime_1_PvQpGdP7XerkPpRuxddI" GlobalId="1_PvQpGdP7XerkPpRuxddI" Name="WeatherDowntime" Description="Weather downtime proportion" TemplateType="p_singlevalue" PrimaryMeasureType="IfcRatioMeasure" />
				<IfcSimplePropertyTemplate id="Weathering_0e5dTwbh19SRXa21Al10uH" GlobalId="0e5dTwbh19SRXa21Al10uH" Name="Weathering" Description="Description of the physical and chemical changes produced by atmospheric agents in rocks or other deposits at or near the earth&apos;s surface. These changes result in disintegration and de composition of the material." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="Weathering_1Sb_Wrxcr569u3CJuzXzLj" GlobalId="1Sb_Wrxcr569u3CJuzXzLj" Name="Weathering" Description="Description of the physical and chemical changes produced by atmospheric agents in rocks or other deposits at or near the earth&apos;s surface. These changes result in disintegration and de composition of the material." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="Weathering_3i$R3pRvTADgYlPxiIMGTo" GlobalId="3i$R3pRvTADgYlPxiIMGTo" Name="Weathering" Description="Description of the physical and chemical changes produced by atmospheric agents in rocks or other deposits at or near the earth&apos;s surface. These changes result in disintegration and decomposition of the material." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="Weathering_3VudkS3GP7whCc9fnu5Tf9" GlobalId="3VudkS3GP7whCc9fnu5Tf9" Name="Weathering" Description="Description of the physical and chemical changes produced by atmospheric agents in rocks or other deposits at or near the earth&apos;s surface. These changes result in disintegration and decomposition of the material.
&gt; NOTE Definition according to ISO 14689:2017." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_Weathering">
						<EnumerationValues>
							<IfcLabel-wrapper>FRESH</IfcLabel-wrapper>
							<IfcLabel-wrapper>DISCOLOURED</IfcLabel-wrapper>
							<IfcLabel-wrapper>DISINTEGRATED</IfcLabel-wrapper>
							<IfcLabel-wrapper>DECOMPOSED</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="Weight_2EgP40qSSHuO00025QrE$V" GlobalId="2EgP40qSSHuO00025QrE$V" Name="Weight" Description="Total weight of object

Weight of cable kg/km." TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassMeasure" />
				<IfcSimplePropertyTemplate id="Weight_2nY7K0qSWHuO00025QrE$V" GlobalId="2nY7K0qSWHuO00025QrE$V" Name="Weight" Description="Total weight of object

Weight of core kg/km." TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassMeasure" />
				<IfcSimplePropertyTemplate id="Weight_3CjQs0qUKHuO00025QrE$V" GlobalId="3CjQs0qUKHuO00025QrE$V" Name="Weight" Description="Total weight of object" TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassMeasure" />
				<IfcSimplePropertyTemplate id="Weight_3MsQi0qUaHuO00025QrE$V" GlobalId="3MsQi0qUaHuO00025QrE$V" Name="Weight" Description="Total weight of object." TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassMeasure" />
				<IfcSimplePropertyTemplate id="Weight_3v6Vk0qTuHuO00025QrE$V" GlobalId="3v6Vk0qTuHuO00025QrE$V" Name="Weight" Description="Total weight of object" TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassMeasure" />
				<IfcSimplePropertyTemplate id="WeightedEfficiency_0vV7W0qUKHuO00025QrE$V" GlobalId="0vV7W0qUKHuO00025QrE$V" Name="WeightedEfficiency" Description="Filter efficiency based the particle weight concentration before and after filter against particles with certain size distribution." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="WeightedEfficiencyCurve_2bztS0qUKHuO00025QrE$V" GlobalId="2bztS0qUKHuO00025QrE$V" Name="WeightedEfficiencyCurve" Description="Weighted efficiency curve as a function of dust holding weight, efficiency = f (dust holding weight)." TemplateType="p_tablevalue" PrimaryMeasureType="IfcMassMeasure" SecondaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="WeldDiameter_3vjP20qUGHuO00025QrE$V" GlobalId="3vjP20qUGHuO00025QrE$V" Name="WeldDiameter" Description="Dimension of the required hole diameter at the faying surface, or required spot weld diameter at the faying surface, or required stud diameter.

&gt; REFERENCE&amp;nbsp; Symbol d according to ISO 2553:2019." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="WeldElementLength_07QnO0qUKHuO00025QrE$V" GlobalId="07QnO0qUKHuO00025QrE$V" Name="WeldElementLength" Description="Length of each weld element.

&gt; REFERENCE&amp;nbsp; Symbol l according to ISO 2553:2019." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="WeldElementSpacing_00t9w0qUKHuO00025QrE$V" GlobalId="00t9w0qUKHuO00025QrE$V" Name="WeldElementSpacing" Description="Spacing between weld elements (centre to centre)

&gt; REFERENCE&amp;nbsp; Symbol e according to ISO 2553:2019." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="WeldLegLength_0QVUO0qUKHuO00025QrE$V" GlobalId="0QVUO0qUKHuO00025QrE$V" Name="WeldLegLength" Description="Distance from the actual or projected intersection of the fusion faces and the toe of a fillet weld, measured across the fusion face.

&gt; REFERENCE&amp;nbsp; Symbol z according to ISO 2553:2019." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="WeldWidth_3p9na0qUGHuO00025QrE$V" GlobalId="3p9na0qUGHuO00025QrE$V" Name="WeldWidth" Description="Required elongated hole width at the faying surface or seam weld width at the faying surface.

&gt; REFERENCE&amp;nbsp; Symbol c according to ISO 2553:2019." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="WetBulbTemperature_16vijFFij05hFPKkmcWspc" GlobalId="16vijFFij05hFPKkmcWspc" Name="WetBulbTemperature" Description="Wet bulb temperature of the air." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="WetBulbTemperatureHistory_30J$B7lK58sesE0tH79del" GlobalId="30J$B7lK58sesE0tH79del" Name="WetBulbTemperatureHistory" Description="Wet bulb temperature of the fluid; only applicable if the fluid is air." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcThermodynamicTemperatureMeasure" />
				<IfcSimplePropertyTemplate id="WetBulkDensity_0zymFCuR5CTx4wkxmFWmPt" GlobalId="0zymFCuR5CTx4wkxmFWmPt" Name="WetBulkDensity" Description="Ratio of the total mass to the unit total volume (material at its natural moisture content)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcMassDensityMeasure" />
				<IfcSimplePropertyTemplate id="WetBulkDensity_2I9krS8W54Uezs_moDPWYf" GlobalId="2I9krS8W54Uezs_moDPWYf" Name="WetBulkDensity" Description="Ratio of the total mass to the unit total volume (material at its natural moisture content)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="WetCoilFraction_12h1k0qSeHuO00025QrE$V" GlobalId="12h1k0qSeHuO00025QrE$V" Name="WetCoilFraction" Description="Fraction of coil surface area that is wet (0-1)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcNormalisedRatioMeasure" />
				<IfcSimplePropertyTemplate id="WheelTipSpeed_0ZkeC0qUGHuO00025QrE$V" GlobalId="0ZkeC0qUGHuO00025QrE$V" Name="WheelTipSpeed" Description="Fan blade tip speed, typically defined as the linear speed of the tip of the fan blade furthest from the shaft." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcLinearVelocityMeasure" />
				<IfcSimplePropertyTemplate id="WideChannelWidth_3SSA9HxpbBze$AzEvzUdRN" GlobalId="3SSA9HxpbBze$AzEvzUdRN" Name="WideChannelWidth" Description="Indicates the width of the wide channel." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="Width_1XM_E0qSKHuO00025QrE$V" GlobalId="1XM_E0qSKHuO00025QrE$V" Name="Width" Description="The requested width (horizontal extension in elevation) of the provision for void, only provided if the Shape property is set to &quot;rectangle&quot;." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="Width_3cvf00qTCHuO00025QrE$V" GlobalId="3cvf00qTCHuO00025QrE$V" Name="Width" Description="The width of the object. Only given, if the object has constant thickness (prismatic)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="Width_3jZbKSm1T9JwAjrhRilc2T" GlobalId="3jZbKSm1T9JwAjrhRilc2T" Name="Width" Description="The width of the object. Only given, if the object has constant thickness (prismatic)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="WinchBreakLimit_2wHzhEvrvETAgnkW9TL1me" GlobalId="2wHzhEvrvETAgnkW9TL1me" Name="WinchBreakLimit" Description="Line force at which the winch starts to release the line (maximum load)" TemplateType="p_singlevalue" PrimaryMeasureType="IfcForceMeasure" />
				<IfcSimplePropertyTemplate id="WindAngleRange_1DH_IenR1EWgR3G1pApMRJ" GlobalId="1DH_IenR1EWgR3G1pApMRJ" Name="WindAngleRange" Description="Indicates the wind angle range the sensor can monitor." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPlaneAngleMeasure" />
				<IfcSimplePropertyTemplate id="WindLoadRating_1cI8AXMuf208Vs_0Pmo_8B" GlobalId="1cI8AXMuf208Vs_0Pmo_8B" Name="WindLoadRating" Description="Wind load resistance rating for this object.
It is provided according to the national building code." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="WindLoadRating_2Ru8al_J91DRslpPXuAcJ$" GlobalId="2Ru8al_J91DRslpPXuAcJ$" Name="WindLoadRating" Description="Wind load resistance rating for this object.
It is provided according to the national building code." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="WindSensorType_2YmBC0qWOHuO00025QrE$V" GlobalId="2YmBC0qWOHuO00025QrE$V" Name="WindSensorType" Description="Enumeration that Identifies the types of wind sensors that can be specified." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_WindSensorType">
						<EnumerationValues>
							<IfcLabel-wrapper>CUP</IfcLabel-wrapper>
							<IfcLabel-wrapper>WINDMILL</IfcLabel-wrapper>
							<IfcLabel-wrapper>HOTWIRE</IfcLabel-wrapper>
							<IfcLabel-wrapper>LASERDOPPLER</IfcLabel-wrapper>
							<IfcLabel-wrapper>SONIC</IfcLabel-wrapper>
							<IfcLabel-wrapper>PLATE</IfcLabel-wrapper>
							<IfcLabel-wrapper>TUBE</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="WindSpeedRange_3prEZg_014axLq1m30EpZt" GlobalId="3prEZg_014axLq1m30EpZt" Name="WindSpeedRange" Description="Indicates the range of wind speed the sensor can monitor." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcLinearVelocityMeasure" />
				<IfcSimplePropertyTemplate id="WireDiameter_0MICq0qTCHuO00025QrE$V" GlobalId="0MICq0qTCHuO00025QrE$V" Name="WireDiameter" Description="The nominal diameter of the wire." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="WireEmbeddingLength_0bBt_0qTCHuO00025QrE$V" GlobalId="0bBt_0qTCHuO00025QrE$V" Name="WireEmbeddingLength" Description="The length of the part of wire which is embedded in the precast concrete element." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="WireLoopBasePlateLength_0EYIY0qTCHuO00025QrE$V" GlobalId="0EYIY0qTCHuO00025QrE$V" Name="WireLoopBasePlateLength" Description="The length of the base plate." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="WireLoopBasePlateThickness_00Emo0qTCHuO00025QrE$V" GlobalId="00Emo0qTCHuO00025QrE$V" Name="WireLoopBasePlateThickness" Description="The thickness of the base plate." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="WireLoopBasePlateWidth_05c5S0qTCHuO00025QrE$V" GlobalId="05c5S0qTCHuO00025QrE$V" Name="WireLoopBasePlateWidth" Description="The width of the base plate." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="WireLoopLength_0ovGK0qTCHuO00025QrE$V" GlobalId="0ovGK0qTCHuO00025QrE$V" Name="WireLoopLength" Description="The length of the fastening loop part of the wire." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="WirePairType_3VzXtlphv2zPqieA4Gh1SM" GlobalId="3VzXtlphv2zPqieA4Gh1SM" Name="WirePairType" Description="Indicates the type of wire pair, i.e., twisted, untwisted or coaxial pair." TemplateType="p_enumeratedvalue" PrimaryMeasureType="IfcLabel">
					<Enumerators xsi:type="IfcPropertyEnumeration" Name="PEnum_WirePairType">
						<EnumerationValues>
							<IfcLabel-wrapper>COAXIAL</IfcLabel-wrapper>
							<IfcLabel-wrapper>TWISTED</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNTWISTED</IfcLabel-wrapper>
							<IfcLabel-wrapper>OTHER</IfcLabel-wrapper>
							<IfcLabel-wrapper>NOTKNOWN</IfcLabel-wrapper>
							<IfcLabel-wrapper>UNSET</IfcLabel-wrapper>
						</EnumerationValues>
					</Enumerators>
				</IfcSimplePropertyTemplate>
				<IfcSimplePropertyTemplate id="WithBackdrop_0TlAO0qTGHuO00025QrE$V" GlobalId="0TlAO0qTGHuO00025QrE$V" Name="WithBackdrop" Description="Indicates whether the chamber has a backdrop or tumbling bay (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="WithBackdrop_2uQBK0qTCHuO00025QrE$V" GlobalId="2uQBK0qTCHuO00025QrE$V" Name="WithBackdrop" Description="Indicates whether the chamber has a backdrop or tumbling bay (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="WithLightningRod_3pPNiRy4X9KvANfnRk92$0" GlobalId="3pPNiRy4X9KvANfnRk92$0" Name="WithLightningRod" Description="Indicates whether the element is equipped with a lightning rod (TRUE) or not (FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="WithLock_0uvU20qUaHuO00025QrE$V" GlobalId="0uvU20qUaHuO00025QrE$V" Name="WithLock" Description="Indicates whether the file cabinet is lockable (= TRUE) or not (= FALSE)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcBoolean" />
				<IfcSimplePropertyTemplate id="Workability_3yj7y0qUmHuO00025QrE$V" GlobalId="3yj7y0qUmHuO00025QrE$V" Name="Workability" Description="Description of the workability of the fresh concrete defined according to local standards." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="WorkDayDuration_0S_ZC0qXaHuO00025QrE$V" GlobalId="0S_ZC0qXaHuO00025QrE$V" Name="WorkDayDuration" Description="The elapsed time within a worktime-based day. For presentation purposes, applications may choose to display IfcTask durations in work days where IfcTaskTime.DurationType=WORKTIME. This value must be less than or equal to 24 hours (an elapsed day); if omitted then 8 hours is assumed." TemplateType="p_singlevalue" PrimaryMeasureType="IfcDuration" />
				<IfcSimplePropertyTemplate id="WorkExecutionLevel_2iUDdWqvj3zAyiUtMMrWPd" GlobalId="2iUDdWqvj3zAyiUtMMrWPd" Name="WorkExecutionLevel" Description="Adjustment of the service life resulting from the effect of the quality of work executed." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPositiveRatioMeasure" />
				<IfcSimplePropertyTemplate id="WorkFinishTime_0NdEY0qXaHuO00025QrE$V" GlobalId="0NdEY0qXaHuO00025QrE$V" Name="WorkFinishTime" Description="The default time of day a task is scheduled to finish. For presentation purposes, if the finish time of a task matches the WorkFinishTime, then applications may choose to display the date only. Conversely when entering dates without specifying time, applications may automatically append the WorkFinishTime." TemplateType="p_singlevalue" PrimaryMeasureType="IfcTime" />
				<IfcSimplePropertyTemplate id="WorkflowProcess_2P1FpkQRT6cR$TKisPYw_h" GlobalId="2P1FpkQRT6cR$TKisPYw_h" Name="WorkflowProcess" Description="Reference to the designed/As-Built process for the grouting." TemplateType="p_referencevalue" PrimaryMeasureType="IfcDocumentReference" SecondaryMeasureType="IfcURIReference" />
				<IfcSimplePropertyTemplate id="WorkingPressure_1_QzC0qXGHuO00025QrE$V" GlobalId="1_QzC0qXGHuO00025QrE$V" Name="WorkingPressure" Description="Working pressure.

The normally expected maximum working pressure of the valve." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="WorkingPressure_2C1cO0qTuHuO00025QrE$V" GlobalId="2C1cO0qTuHuO00025QrE$V" Name="WorkingPressure" Description="Working pressure.

Pressure classification as defined by the authority having jurisdiction (e.g., SMACNA, etc.)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="WorkingPressure_2dBw20qVCHuO00025QrE$V" GlobalId="2dBw20qVCHuO00025QrE$V" Name="WorkingPressure" Description="Working pressure." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="WorkingPressureHistory_1D$4Y0qSGHuO00025QrE$V" GlobalId="1D$4Y0qSGHuO00025QrE$V" Name="WorkingPressureHistory" Description="Boiler working pressure." TemplateType="p_referencevalue" PrimaryMeasureType="IfcTimeSeries" SecondaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="WorkingPressureRange_06Dkg0qTyHuO00025QrE$V" GlobalId="06Dkg0qTyHuO00025QrE$V" Name="WorkingPressureRange" Description="Allowable minimum and maximum  working pressure (relative to ambient pressure)." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="WorkingState_2qD57tYLb86QIkv8vmjv3f" GlobalId="2qD57tYLb86QIkv8vmjv3f" Name="WorkingState" Description="Indicates the working state of device or system." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="WorkMonthDuration_0djCW0qXaHuO00025QrE$V" GlobalId="0djCW0qXaHuO00025QrE$V" Name="WorkMonthDuration" Description="The elapsed time within a worktime-based month. For presentation purposes, applications may choose to display IfcTask durations in work months where IfcTaskTime.DurationType=WORKTIME. This value must be less than or equal to 744 hours (an elapsed month of 31 days); if omitted then 160 hours is assumed." TemplateType="p_singlevalue" PrimaryMeasureType="IfcDuration" />
				<IfcSimplePropertyTemplate id="WorkStartTime_0Is3I0qXaHuO00025QrE$V" GlobalId="0Is3I0qXaHuO00025QrE$V" Name="WorkStartTime" Description="The default time of day a task is scheduled to start. For presentation purposes, if the start time of a task matches the WorkStartTime, then applications may choose to display the date only. Conversely when entering dates without specifying time, applications may automatically append the WorkStartTime." TemplateType="p_singlevalue" PrimaryMeasureType="IfcTime" />
				<IfcSimplePropertyTemplate id="WorksurfaceArea_0i_Xw0qUaHuO00025QrE$V" GlobalId="0i_Xw0qUaHuO00025QrE$V" Name="WorksurfaceArea" Description="The value of the work surface area of the desk." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAreaMeasure" />
				<IfcSimplePropertyTemplate id="WorksurfaceArea_16csO0qUaHuO00025QrE$V" GlobalId="16csO0qUaHuO00025QrE$V" Name="WorksurfaceArea" Description="The value of the work surface area of the desk." TemplateType="p_singlevalue" PrimaryMeasureType="IfcAreaMeasure" />
				<IfcSimplePropertyTemplate id="WorkTypeRequested_07A4O0qVWHuO00025QrE$V" GlobalId="07A4O0qVWHuO00025QrE$V" Name="WorkTypeRequested" Description="Work type requested in circumstances where there are categorizations of types of work task. It could be used to identify a remedial task, minor work task, electrical task etc." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="WorkTypeRequested_1S5uo0qVSHuO00025QrE$V" GlobalId="1S5uo0qVSHuO00025QrE$V" Name="WorkTypeRequested" Description="Work type requested in circumstances where there are categorizations of types of work task. It could be used to identify a remedial task, minor work task, electrical task etc." TemplateType="p_singlevalue" PrimaryMeasureType="IfcText" />
				<IfcSimplePropertyTemplate id="WorkWeekDuration_0Yy1G0qXaHuO00025QrE$V" GlobalId="0Yy1G0qXaHuO00025QrE$V" Name="WorkWeekDuration" Description="The elapsed time within a worktime-based week. For presentation purposes, applications may choose to display IfcTask durations in work weeks where IfcTaskTime.DurationType=WORKTIME. This value must be less than or equal to 168 hours (an elapsed week); if omitted then 40 hours is assumed." TemplateType="p_singlevalue" PrimaryMeasureType="IfcDuration" />
				<IfcSimplePropertyTemplate id="WrappingMaterial_17XCM0qV8HuO00025QrE$V" GlobalId="17XCM0qV8HuO00025QrE$V" Name="WrappingMaterial" Description="Special requirements for material used to wrap an artefact." TemplateType="p_referencevalue" PrimaryMeasureType="IfcMaterialDefinition" />
				<IfcSimplePropertyTemplate id="WWWHomePageURL_2S_ezjK2D8XvmeXBJ53GlF" GlobalId="2S_ezjK2D8XvmeXBJ53GlF" Name="WWWHomePageURL" Description="The world wide web address at which the preliminary page of information for the person or organization can be located.

&gt; NOTE&amp;nbsp; Information on the world wide web for a person or organization may be separated into a number of pages and across a number of host sites, all of which may be linked together. It is assumed that all such information may be referenced from a single page that is termed the home page for that person or organization." TemplateType="p_singlevalue" PrimaryMeasureType="IfcURIReference" />
				<IfcSimplePropertyTemplate id="XDirectionLowerBarCount_2goII0qVyHuO00025QrE$V" GlobalId="2goII0qVyHuO00025QrE$V" Name="XDirectionLowerBarCount" Description="The number of bars with X direction lower bar." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="XDirectionTieHoopBarPitch_08NN40qW0HuO00025QrE$V" GlobalId="08NN40qW0HuO00025QrE$V" Name="XDirectionTieHoopBarPitch" Description="The X direction pitch length of the tie hoop." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="XDirectionTieHoopCount_0G7HM0qW0HuO00025QrE$V" GlobalId="0G7HM0qW0HuO00025QrE$V" Name="XDirectionTieHoopCount" Description="The number of bars with X direction tie hoop bars." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="XDirectionUpperBarCount_2qKeo0qVyHuO00025QrE$V" GlobalId="2qKeo0qVyHuO00025QrE$V" Name="XDirectionUpperBarCount" Description="The number of bars with X direction upper bar." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="YDirectionLowerBarCount_2lZTY0qVyHuO00025QrE$V" GlobalId="2lZTY0qVyHuO00025QrE$V" Name="YDirectionLowerBarCount" Description="The number of bars with Y direction lower bar." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="YDirectionTieHoopBarPitch_0KuSc0qW0HuO00025QrE$V" GlobalId="0KuSc0qW0HuO00025QrE$V" Name="YDirectionTieHoopBarPitch" Description="The Y direction pitch length of the tie hoop." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
				<IfcSimplePropertyTemplate id="YDirectionTieHoopCount_0SeMu0qW0HuO00025QrE$V" GlobalId="0SeMu0qW0HuO00025QrE$V" Name="YDirectionTieHoopCount" Description="The number of bars with Y direction tie hoop bars." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="YDirectionUpperBarCount_2v5q20qVyHuO00025QrE$V" GlobalId="2v5q20qVyHuO00025QrE$V" Name="YDirectionUpperBarCount" Description="The number of bars with Y direction upper bar." TemplateType="p_singlevalue" PrimaryMeasureType="IfcCountMeasure" />
				<IfcSimplePropertyTemplate id="YearOfConstruction_0XbFm0qSKHuO00025QrE$V" GlobalId="0XbFm0qSKHuO00025QrE$V" Name="YearOfConstruction" Description="Year of construction of this building, including expected year of completion." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="YearOfLastRefurbishment_0cMR00qSKHuO00025QrE$V" GlobalId="0cMR00qSKHuO00025QrE$V" Name="YearOfLastRefurbishment" Description="Year of last major refurbishment, or reconstruction, of the building (applies to reconstruction works)." TemplateType="p_singlevalue" PrimaryMeasureType="IfcLabel" />
				<IfcSimplePropertyTemplate id="YieldStress_3JuBc0qUqHuO00025QrE$V" GlobalId="3JuBc0qUqHuO00025QrE$V" Name="YieldStress" Description="A measure of the yield stress (or characteristic 0.2 percent proof stress) of the material." TemplateType="p_singlevalue" PrimaryMeasureType="IfcPressureMeasure" />
				<IfcSimplePropertyTemplate id="YoungModulus_1HMLggJlb57v8ii$EHduxM" GlobalId="1HMLggJlb57v8ii$EHduxM" Name="YoungModulus" Description="Elastic modulus, mean value, α=0°." TemplateType="p_singlevalue" PrimaryMeasureType="IfcModulusOfElasticityMeasure" />
				<IfcSimplePropertyTemplate id="YoungModulus_1hvsC0IWLEdB3xUkvrCHVI" GlobalId="1hvsC0IWLEdB3xUkvrCHVI" Name="YoungModulus" Description="Elastic modulus, mean value, α=0°." TemplateType="p_singlevalue" PrimaryMeasureType="IfcModulusOfElasticityMeasure" />
				<IfcSimplePropertyTemplate id="YoungModulus_1x4I40qUqHuO00025QrE$V" GlobalId="1x4I40qUqHuO00025QrE$V" Name="YoungModulus" Description="A measure of the Young&apos;s modulus of elasticity of the material." TemplateType="p_singlevalue" PrimaryMeasureType="IfcModulusOfElasticityMeasure" />
				<IfcSimplePropertyTemplate id="YoungModulus_2bHaV6RhX4uRp9L8cVVGMA" GlobalId="2bHaV6RhX4uRp9L8cVVGMA" Name="YoungModulus" Description="Elastic modulus, mean value, α=0°." TemplateType="p_singlevalue" PrimaryMeasureType="IfcModulusOfElasticityMeasure" />
				<IfcSimplePropertyTemplate id="YoungModulusBending_2iUxE2okX3qe97DmCl4Kk0" GlobalId="2iUxE2okX3qe97DmCl4Kk0" Name="YoungModulusBending" Description="Defining values: α; defined values: elastic modulus in bending." TemplateType="p_tablevalue" PrimaryMeasureType="IfcPositivePlaneAngleMeasure" SecondaryMeasureType="IfcModulusOfElasticityMeasure" />
				<IfcSimplePropertyTemplate id="YoungModulusBending_2KkhzDTjv3YRviVgrvcNNu" GlobalId="2KkhzDTjv3YRviVgrvcNNu" Name="YoungModulusBending" Description="Defining values: α; defined values: elastic modulus in bending." TemplateType="p_tablevalue" PrimaryMeasureType="IfcPositivePlaneAngleMeasure" SecondaryMeasureType="IfcModulusOfElasticityMeasure" />
				<IfcSimplePropertyTemplate id="YoungModulusBending_3uXvMh_E9EShawFv3umm3E" GlobalId="3uXvMh_E9EShawFv3umm3E" Name="YoungModulusBending" Description="Defining values: α; defined values: elastic modulus in bending." TemplateType="p_tablevalue" PrimaryMeasureType="IfcPositivePlaneAngleMeasure" SecondaryMeasureType="IfcModulusOfElasticityMeasure" />
				<IfcSimplePropertyTemplate id="YoungModulusCompression_0rZyHKD5H1QQmUECnOzXOq" GlobalId="0rZyHKD5H1QQmUECnOzXOq" Name="YoungModulusCompression" Description="Elastic modulus in compression." TemplateType="p_singlevalue" PrimaryMeasureType="IfcModulusOfElasticityMeasure" />
				<IfcSimplePropertyTemplate id="YoungModulusCompression_0UWm95OrnBgR9a7x_pJo76" GlobalId="0UWm95OrnBgR9a7x_pJo76" Name="YoungModulusCompression" Description="Elastic modulus in compression." TemplateType="p_singlevalue" PrimaryMeasureType="IfcModulusOfElasticityMeasure" />
				<IfcSimplePropertyTemplate id="YoungModulusCompression_2TBmvZhuz3SObcIgA95UZK" GlobalId="2TBmvZhuz3SObcIgA95UZK" Name="YoungModulusCompression" Description="Elastic modulus in compression." TemplateType="p_singlevalue" PrimaryMeasureType="IfcModulusOfElasticityMeasure" />
				<IfcSimplePropertyTemplate id="YoungModulusMin_1GWNFoFaz07OonloBxZUIU" GlobalId="1GWNFoFaz07OonloBxZUIU" Name="YoungModulusMin" Description="Elastic modulus, minimal value, α=0°." TemplateType="p_singlevalue" PrimaryMeasureType="IfcModulusOfElasticityMeasure" />
				<IfcSimplePropertyTemplate id="YoungModulusMin_2tQS09ZAPDug98trzpu7PS" GlobalId="2tQS09ZAPDug98trzpu7PS" Name="YoungModulusMin" Description="Elastic modulus, minimal value, α=0°." TemplateType="p_singlevalue" PrimaryMeasureType="IfcModulusOfElasticityMeasure" />
				<IfcSimplePropertyTemplate id="YoungModulusMin_3A0o4GtqT6OBDykSCG4qAD" GlobalId="3A0o4GtqT6OBDykSCG4qAD" Name="YoungModulusMin" Description="Elastic modulus, minimal value, α=0°." TemplateType="p_singlevalue" PrimaryMeasureType="IfcModulusOfElasticityMeasure" />
				<IfcSimplePropertyTemplate id="YoungModulusPerp_0hIiFZeVTDb921yIdyCwiO" GlobalId="0hIiFZeVTDb921yIdyCwiO" Name="YoungModulusPerp" Description="Elastic modulus, mean value, α=90°." TemplateType="p_singlevalue" PrimaryMeasureType="IfcModulusOfElasticityMeasure" />
				<IfcSimplePropertyTemplate id="YoungModulusPerp_1mmoX5pdz3LBznp4oPUJYs" GlobalId="1mmoX5pdz3LBznp4oPUJYs" Name="YoungModulusPerp" Description="Elastic modulus, mean value, α=90°." TemplateType="p_singlevalue" PrimaryMeasureType="IfcModulusOfElasticityMeasure" />
				<IfcSimplePropertyTemplate id="YoungModulusPerp_3yy5ZSDFD8jfjbdsMRuc1y" GlobalId="3yy5ZSDFD8jfjbdsMRuc1y" Name="YoungModulusPerp" Description="Elastic modulus, mean value, α=90°." TemplateType="p_singlevalue" PrimaryMeasureType="IfcModulusOfElasticityMeasure" />
				<IfcSimplePropertyTemplate id="YoungModulusPerpMin_0X8QZuXmT2JfERY_t1KRKN" GlobalId="0X8QZuXmT2JfERY_t1KRKN" Name="YoungModulusPerpMin" Description="Elastic modulus, minimal value, α=90°." TemplateType="p_singlevalue" PrimaryMeasureType="IfcModulusOfElasticityMeasure" />
				<IfcSimplePropertyTemplate id="YoungModulusPerpMin_2carIhWoz99Po3SSzAJPct" GlobalId="2carIhWoz99Po3SSzAJPct" Name="YoungModulusPerpMin" Description="Elastic modulus, minimal value, α=90°." TemplateType="p_singlevalue" PrimaryMeasureType="IfcModulusOfElasticityMeasure" />
				<IfcSimplePropertyTemplate id="YoungModulusPerpMin_2qRhing2D7fv1FZXFdK1uq" GlobalId="2qRhing2D7fv1FZXFdK1uq" Name="YoungModulusPerpMin" Description="Elastic modulus, minimal value, α=90°." TemplateType="p_singlevalue" PrimaryMeasureType="IfcModulusOfElasticityMeasure" />
				<IfcSimplePropertyTemplate id="YoungModulusTension_0iG4nofBX9zgQRpfqFJpVy" GlobalId="0iG4nofBX9zgQRpfqFJpVy" Name="YoungModulusTension" Description="Defining values: α; defined values: elastic modulus in tension." TemplateType="p_tablevalue" PrimaryMeasureType="IfcPositivePlaneAngleMeasure" SecondaryMeasureType="IfcModulusOfElasticityMeasure" />
				<IfcSimplePropertyTemplate id="YoungModulusTension_1gkOvTOmH4geO$fUhBUgBZ" GlobalId="1gkOvTOmH4geO$fUhBUgBZ" Name="YoungModulusTension" Description="Defining values: α; defined values: elastic modulus in tension." TemplateType="p_tablevalue" PrimaryMeasureType="IfcPositivePlaneAngleMeasure" SecondaryMeasureType="IfcModulusOfElasticityMeasure" />
				<IfcSimplePropertyTemplate id="YoungModulusTension_2nbX3i7E10Re_fBz1EwEY2" GlobalId="2nbX3i7E10Re_fBz1EwEY2" Name="YoungModulusTension" Description="Defining values: α; defined values: elastic modulus in tension." TemplateType="p_tablevalue" PrimaryMeasureType="IfcPositivePlaneAngleMeasure" SecondaryMeasureType="IfcModulusOfElasticityMeasure" />
				<IfcSimplePropertyTemplate id="ZnContent_02nVJY8$5Dmgcog95HvuLM" GlobalId="02nVJY8$5Dmgcog95HvuLM" Name="ZnContent" Description="Content of Zink. The unit must be defined in _&apos;IfcPropertySingleValue_._Unit&apos;_." TemplateType="p_singlevalue" PrimaryMeasureType="IfcReal" />
				<IfcSimplePropertyTemplate id="Zoom_1Eaz_0qS8HuO00025QrE$V" GlobalId="1Eaz_0qS8HuO00025QrE$V" Name="Zoom" Description="Indicates the zoom range." TemplateType="p_boundedvalue" PrimaryMeasureType="IfcPositiveLengthMeasure" />
			</RelatedDefinitions>
		</IfcRelDeclares>
		<IfcRelDeclares GlobalId="0dJzky7sb6txqIsyVpv7iW" Name="ComplexProperties">
			<RelatedDefinitions>
				<IfcComplexPropertyTemplate id="InPlane_1x4Y20qUyHuO00025QrE$V" GlobalId="1x4Y20qUyHuO00025QrE$V" Name="InPlane" Description="Mechanical properties with respect to in-plane load, i.e. for function as a membrane." TemplateType="p_complex">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulusBending_3uXvMh_E9EShawFv3umm3E" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulusTension_0iG4nofBX9zgQRpfqFJpVy" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulusCompression_0rZyHKD5H1QQmUECnOzXOq" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShearModulus_1BsSTJE8H2BfNbyA5ERUcQ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BendingStrength_3uAmt8haD0dAvgoiwl5n_m" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CompressiveStrength_13o_PQZLnATfkOJGsX$sGN" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TensileStrength_2kzyYyrpv3JQ8F$F0Erxgy" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShearStrength_0t2jQXJuD8tQVtmTYGBx9q" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BearingStrength_33oSGnU852OgqegzmzS5zH" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RaisedCompressiveStrength_24vkFVO3zF59eFBHZdlOH3" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReferenceDepth_18i26IeYfElf48a3m5DXxE" />
					</HasPropertyTemplates>
				</IfcComplexPropertyTemplate>
				<IfcComplexPropertyTemplate id="InPlane_1zm4O0qUuHuO00025QrE$V" GlobalId="1zm4O0qUuHuO00025QrE$V" Name="InPlane" Description="Mechanical properties with respect to in-plane load, i.e. bending about the strong axis; tension zone of unbalanced layups is stressed in tension." TemplateType="p_complex">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulus_1HMLggJlb57v8ii$EHduxM" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulusMin_2tQS09ZAPDug98trzpu7PS" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulusPerp_1mmoX5pdz3LBznp4oPUJYs" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulusPerpMin_0X8QZuXmT2JfERY_t1KRKN" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShearModulus_0LyBqEuor3xhVDmdpBBrhS" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShearModulusMin_0BABvT9ifCweKQpbVbmW1v" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BendingStrength_3Y5KkhnojDTerh9JKKXi0W" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TensileStrength_2AKW2E71v4SwZRSf6Bjv2w" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TensileStrengthPerp_0j8x5DwHH4rgxxNUUYpaxH" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CompStrength_0N455YE$f0Q9gp2KsnM8YB" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CompStrengthPerp_1nDJCoibTCpv6h14fhaGKZ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RaisedCompStrengthPerp_1e6FFTtjLBgOZ8z29e$3k7" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShearStrength_0kjgupy_97avIlMZH_iBD4" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TorsionalStrength_1EHJyVIez4GuVXUZSpQHn3" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReferenceDepth_2IRbhBomnFhx9eIoVOIJHC" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InstabilityFactors_3RdbqocJXF8uEl6oXjVCGl" />
					</HasPropertyTemplates>
				</IfcComplexPropertyTemplate>
				<IfcComplexPropertyTemplate id="InPlaneNegative_3Ddmq0qUuHuO00025QrE$V" GlobalId="3Ddmq0qUuHuO00025QrE$V" Name="InPlaneNegative" Description="Mechanical properties with respect to in-plane load, i.e. bending about the strong axis; compression zone of unbalanced layups is stressed in tension." TemplateType="p_complex">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulus_1hvsC0IWLEdB3xUkvrCHVI" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulusMin_1GWNFoFaz07OonloBxZUIU" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulusPerp_3yy5ZSDFD8jfjbdsMRuc1y" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulusPerpMin_2carIhWoz99Po3SSzAJPct" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShearModulus_0FEmIVJej8$PCIj$EUMR5y" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShearModulusMin_2cuG8RJdnEhhN8yxbhfbVX" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BendingStrength_1mJcyU5FjEvPlHNmb60SjF" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TensileStrength_2XtnNJoVnBmvn1bzc1UGu_" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TensileStrengthPerp_18d5bAXcjCAARdYXKP07Yn" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CompStrength_3VTMcUo6XCeAAYmM_MZLrH" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CompStrengthPerp_3Q2AaIwNj5sfrocKwUvdtT" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RaisedCompStrengthPerp_04LOOIhZr3DBc$B7zq9dxk" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShearStrength_2hFML4Q9j91f5aJi28rNwe" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TorsionalStrength_0YBUxt_nfFj8QBbLScheNB" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReferenceDepth_21e1MA21r7PPjSW27cmYYl" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InstabilityFactors_0xqstoxIX4bRDLvpeP1qs$" />
					</HasPropertyTemplates>
				</IfcComplexPropertyTemplate>
				<IfcComplexPropertyTemplate id="OutOfPlane_0WUCI0qUyHuO00025QrE$V" GlobalId="0WUCI0qUyHuO00025QrE$V" Name="OutOfPlane" Description="Mechanical properties with respect to out-of-plane load, i.e. bending about the weak axis." TemplateType="p_complex">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulus_2bHaV6RhX4uRp9L8cVVGMA" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulusMin_3A0o4GtqT6OBDykSCG4qAD" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulusPerp_0hIiFZeVTDb921yIdyCwiO" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulusPerpMin_2qRhing2D7fv1FZXFdK1uq" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShearModulus_0G5QhnJy98DR0OMDpbIwLY" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShearModulusMin_3eMkkJs1v8TQccVqGUM$iA" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BendingStrength_0mYnO4_dzB4Rfn5rgnJt$x" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TensileStrength_1rOUUKaLX2jg4ES1N0oyri" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TensileStrengthPerp_1_0o7uYgT6WBo3VRKcYGm2" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CompStrength_0KKYZceoj1zOtGz8I7XmVq" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CompStrengthPerp_0Sk7rdMlL1rwa$77Tmc3ZF" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RaisedCompStrengthPerp_3RBkeZwQr0rx9ofkNqvpwS" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShearStrength_2NP$qunRvDaBTXazkik1TE" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TorsionalStrength_0S_uq2KWrCDQRWW5W4PUOa" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReferenceDepth_2kL9bUrL56KxgsvGPmVNem" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InstabilityFactors_06AWQ0_jj70ukx9CZSEl7o" />
					</HasPropertyTemplates>
				</IfcComplexPropertyTemplate>
				<IfcComplexPropertyTemplate id="OutOfPlane_3bAiM0qUyHuO00025QrE$V" GlobalId="3bAiM0qUyHuO00025QrE$V" Name="OutOfPlane" Description="Mechanical properties with respect to out-of-plane load, i.e. for function as a plate; tension zone of unbalanced layups is stressed in tension." TemplateType="p_complex">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulusBending_2iUxE2okX3qe97DmCl4Kk0" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulusTension_1gkOvTOmH4geO$fUhBUgBZ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulusCompression_2TBmvZhuz3SObcIgA95UZK" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShearModulus_2L1buM9pLFHP0$3z2RXBXH" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BendingStrength_3q0eS9kKL9SvOX70nmAK$A" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CompressiveStrength_0gx8OSAsfDaR6Lagjl0obi" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TensileStrength_1O$ABuTcL8EfGi9YcYYahh" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShearStrength_3TzBr2hBjEE9H1QHei6UZg" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BearingStrength_0KJTgColX9Se1gcILtKvQM" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RaisedCompressiveStrength_2QQzGzvunAmPePwQbZoVbQ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReferenceDepth_3AoKH7X0jEjxeJz28q4H$C" />
					</HasPropertyTemplates>
				</IfcComplexPropertyTemplate>
				<IfcComplexPropertyTemplate id="OutOfPlaneNegative_1H3Iu0qV0HuO00025QrE$V" GlobalId="1H3Iu0qV0HuO00025QrE$V" Name="OutOfPlaneNegative" Description="Mechanical properties with respect to out-of-plane load i.e. for function as a plate; compression zone of unbalanced layups is stressed in tension." TemplateType="p_complex">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulusBending_2KkhzDTjv3YRviVgrvcNNu" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulusTension_2nbX3i7E10Re_fBz1EwEY2" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulusCompression_0UWm95OrnBgR9a7x_pJo76" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShearModulus_3mRDnvHKH5pfCYGaCWPwEu" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BendingStrength_1oJsaXinL0WvDVCL88_ITB" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CompressiveStrength_2chwSa9R98gR_aQspFjpC6" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TensileStrength_2alM0KcOr709AqqhRTMkwv" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShearStrength_1AG3tFK1rEUBNEvoZ2jg2s" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BearingStrength_1i7uUGTIL3uA7MvElqB_Gr" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RaisedCompressiveStrength_3qR6XMmWnCgvqSxdQ16rVq" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReferenceDepth_3tD22xOOH0sxuHHjdxP6_W" />
					</HasPropertyTemplates>
				</IfcComplexPropertyTemplate>
			</RelatedDefinitions>
		</IfcRelDeclares>
		<IfcRelDeclares GlobalId="3M4U3yWxr3_gsGvVZ3qXJS" Name="PropertySets">
			<RelatedDefinitions>
				<IfcPropertySetTemplate GlobalId="3KhIU0qRmHuO00025QrE$V" Name="Pset_ActionRequest" Description="An action request is a request for an action to fulfill a need. HISTORY: IFC4: Removed RequestSourceType, RequestDescription, Status" TemplateType="pset_occurrencedriven" ApplicableEntity="IfcActionRequest">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="RequestSourceLabel_3WcEc0qRmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RequestSourceName_3gkkW0qRmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RequestComments_3miCa0qRmHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3trzS0qRmHuO00025QrE$V" Name="Pset_ActorCommon" Description="A property set that enables further classification of actors, including the ability to give a number of actors to be designated as a population, the number being specified as a property to be dealt with as a single value rather than having to aggregate a number of instances of IfcActor." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcActor">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfActors_00oAY0qRqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ActorCategory_1uL4DgMFDB2hgBJy6VL8l2" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SkillLevel_0C6zG0qRqHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0I4RK0qRqHuO00025QrE$V" Name="Pset_ActuatorPHistory" Description="Properties for history of actuators. HISTORY: Added in IFC4." TemplateType="pset_performancedriven" ApplicableEntity="IfcActuator">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="PositionHistory_0Mrca0qRqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="QualityHistory_1z_Gs375PED9dAUPht8BFC" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="StatusHistory_1aJo7SF6zDiuWBtuk6BCna" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0ZMi60qRqHuO00025QrE$V" Name="Pset_ActuatorTypeCommon" Description="Actuator type common attributes." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcActuator">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ActuatorStatus_31OqXYkZzE68AGS6v3SXvr" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FailPosition_12MLE0qRqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ManualOverride_1Dh7y0qRqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ActuatorApplication_08WRpjWCr7ePTPO7WG0_dT" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1KElQ0qRqHuO00025QrE$V" Name="Pset_ActuatorTypeElectricActuator" Description="A device that electrically actuates a control element." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcActuator/ELECTRICACTUATOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ActuatorInputPower_1O$wg0qRqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ElectricActuatorType_1UzOk0qRqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ControlPulseCurrent_1NbOptutP7sPdNxheUF3ur" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1mrow0qRqHuO00025QrE$V" Name="Pset_ActuatorTypeHydraulicActuator" Description="A device that hydraulically actuates a control element." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcActuator/HYDRAULICACTUATOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="InputPressure_1rc_A0qRqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InputFlowrate_1w_Iq0qRqHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2283i0qRqHuO00025QrE$V" Name="Pset_ActuatorTypeLinearActuation" Description="Characteristics of linear actuation of an actuator
History: Replaces Pset_LinearActuator" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcActuator">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Force_27VOM0qRqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Stroke_2Csj00qRqHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2LCmi0qRqHuO00025QrE$V" Name="Pset_ActuatorTypePneumaticActuator" Description="A device that pneumatically actuates a control element" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcActuator/PNEUMATICACTUATOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="InputPressure_2SMXa0qRqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InputFlowrate_2YJ$e0qRqHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2iSVY0qRqHuO00025QrE$V" Name="Pset_ActuatorTypeRotationalActuation" Description="Characteristics of rotational actuation of an actuator
History: Replaces Pset_RotationalActuator" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcActuator">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Torque_2npqC0qRqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RangeAngle_2uzb40qRqHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2I2E6pBUr8V8d$eV$HOYxR" Name="Pset_Address" Description="This Property Set represents an address for delivery of paper based mail and other postal deliveries." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcActor,IfcBuilding,IfcSite">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Purpose_0WRBx2dzz6o8xCwecn3DMi" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Description_3Zrq848Q59lhSMKyRwz2po" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UserDefinedPurpose_0ICrsHByL71B4Ri8aoiWbu" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InternalLocation_2nkZ9bhLfFOumuCOVP2als" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AddressLines_0AokQv7wrDmAJlBklOK2nm" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PostalBox_0tUIthihvEUR0uX5WlybVY" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Town_1CTteV4prAAwNrX0E35Hng" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Region_0Ja2l6PVP6xx9LVICEzJya" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PostalCode_0nTJvBq39DDxmEozSIwMR6" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Country_2k46ND0cj6hhVdRs$WCmhl" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TelephoneNumbers_3ITvlLFlfF6Pxp6nE5VY9V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FacsimileNumbers_1LEVuixsX5lBZLGyTmhuSA" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PagerNumber_0JOaYbZHP97hOKRz09utzf" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ElectronicMailAddresses_1Fb2vEv$TEW9HBS3QLXfbY" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WWWHomePageURL_2S_ezjK2D8XvmeXBJ53GlF" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MessagingIDs_3waTWM9Eb3Q9wMddy_OIVB" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="31Jem0qRqHuO00025QrE$V" Name="Pset_AirSideSystemInformation" Description="Attributes that apply to an air side HVAC system.

&gt; HISTORY: New property set in IFC Release 1.0." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcZone,IfcSpatialZone,IfcSpatialElement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Description_3Zrq848Q59lhSMKyRwz2po" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AirSideSystemType_3MAn_0qRqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AirSideSystemDistributionType_3p_8I0qRqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TotalAirFlow_1wRz7JaXPEwfdUN5bGZWfM" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EnergyGainTotal_08rHW0qRuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AirFlowSensible_2pbRActdTExAvYvnFsgVBp" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EnergyGainSensible_0KA4E0qRuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EnergyLoss_0Qjhi0qRuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InfiltrationDiversitySummer_0c2UQ0qRuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InfiltrationDiversityWinter_0hPp40qRuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ApplianceDiversity_0nzQY0qRuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HeatingTemperatureDelta_0zuMg0qRuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoolingTemperatureDelta_13rqk0qRuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Ventilation_19pIo0qRuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FanPower_1Fmms0qRuHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1NWh80qRuHuO00025QrE$V" Name="Pset_AirTerminalBoxPHistory" Description="Air terminal box performance history attributes." TemplateType="pset_performancedriven" ApplicableEntity="IfcAirTerminalBox">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="DamperPosition_1TU9C0qRuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AtmosphericPressure_1XfB20qRuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Sound_1bE3U0qRuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AirFlowCurve_3XzvE1K1L4qhIMCR0uz5em" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1kmP_0qRuHuO00025QrE$V" Name="Pset_AirTerminalBoxTypeCommon" Description="Air terminal box type common attributes." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcAirTerminalBox">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_1z3xk0qRuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AirFlowRateRange_2ApJq0qSuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AirPressureRange_2P4rq0qRuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalAirFlowRate_2XQvW0qRuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ArrangementType_2dONa0qRuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReheatType_2rhvK0qRuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasSoundAttenuator_38ASw0qRuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasReturnAir_3DXna0qRuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasFan_3JVFe0qRuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalInletAirPressure_3PSji0qRuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalDamperDiameter_3VQBm0qRuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HousingThickness_3anWQ0qRuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OperationTemperatureRange_3gk_U0qRuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReturnAirFractionRange_3nulM0qRuHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3wEp20qRuHuO00025QrE$V" Name="Pset_AirTerminalOccurrence" Description="Air terminal occurrence attributes attached to an instance of IfcAirTerminal." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcAirTerminal">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="AirFlowType_22N32mXRjDo92Q01qpFItv" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AirFlowRate_29tKZHinXF9Pd1BmREa4Pc" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AirTerminalLocation_0Fi5g0qRyHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0aZEu0qRyHuO00025QrE$V" Name="Pset_AirTerminalPHistory" Description="Air terminal performance history common attributes." TemplateType="pset_performancedriven" ApplicableEntity="IfcAirTerminal">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="AirFlowRateHistory_0h6sM0qRyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NeckAirVelocity_0khko0qRyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SupplyAirTemperatureHeating_0osme0qRyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SupplyAirTemperatureCooling_0sRf40qRyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PressureDrop_0wcgw0qRyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InductionRatio_0zbPy0qRyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CenterlineAirVelocity_16Xd20qRyHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1FTq80qRyHuO00025QrE$V" Name="Pset_AirTerminalTypeCommon" Description="Air terminal type common attributes.
SoundLevel attribute deleted in IFC2x2 Pset Addendum: Use IfcSoundProperties instead." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcAirTerminal">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_1Sb340qRyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AirTerminalShape_1hUkE0qRyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FaceType_1xaiC0qRyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SlotWidth_2H1_q0qRyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SlotLength_2MPJU0qRyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfSlots_2SMnY0qRyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FlowPattern_2YKFc0qRyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AirFlowRateRange_2tBOq0qRyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TemperatureRange_2_L9i0qRyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DischargeDirection_36hDO0qRyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ThrowLength_3K_l80qRyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AirDiffusionPerformanceIndex_3TwyE0qRyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FinishType_3ZIGu0qRyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FinishColour_3mPVq0qRyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AirTerminalMountingType_3sz7I0qRyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoreType_0735G0qS0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoreSetHorizontal_0Qjxg0qS0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoreSetVertical_0VV6w0qS0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasIntegralControl_0bSa_0qS0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FlowControlType_0gDmE0qS0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasSoundAttenuator_0vjao0qS0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasThermalInsulation_0$4vS0qS0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NeckArea_14SE60qS0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EffectiveArea_19pYm0qS0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AirFlowrateVersusFlowControlElement_1GNAE0qS0HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1PvWk0qS0HuO00025QrE$V" Name="Pset_AirToAirHeatRecoveryPHistory" Description="Air to Air Heat Recovery performance history common attributes." TemplateType="pset_performancedriven" ApplicableEntity="IfcAirToAirHeatRecovery">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SensibleEffectiveness_1WT8C0qS0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TotalEffectiveness_1a20e0qS0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TemperatureEffectiveness_1dcv40qS0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DefrostTemperatureEffectiveness_1iO4K0qS0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HumidityEffectiveness_1lMpM0qS0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SensibleHeatTransferRate_1pXrC0qS0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LatentHeatTransferRate_1tit20qS0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TotalHeatTransferRate_1xHlU0qS0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SensibleEffectivenessTable_1_sdw0qS0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TotalEffectivenessTable_22RWM0qS0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AirPressureDropCurves_260Oo0qS0HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2Ca0G0qS0HuO00025QrE$V" Name="Pset_AirToAirHeatRecoveryTypeCommon" Description="Air to Air Heat Recovery type common attributes." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcAirToAirHeatRecovery">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_2OUyO0qS0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HeatTransferTypeEnum_2eawM0qS0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasDefrost_2tUbW0qS0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OperationalTemperatureRange_2_eMO0qS0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PrimaryAirFlowRateRange_3Hj3O0qS0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SecondaryAirFlowRateRange_3RFPu0qS0HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3anmO0qS0HuO00025QrE$V" Name="Pset_AlarmPHistory" Description="Properties for history of alarm values. HISTORY: Added in IFC4." TemplateType="pset_performancedriven" ApplicableEntity="IfcAlarm">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Enabled_3g9520qS0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConditionHistory_3lWPi0qS0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Severity_3phRY0qS0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Acknowledge_3v2mC0qS0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UserHistory_3ydee0qS0HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="01_zI0qS4HuO00025QrE$V" Name="Pset_AlarmTypeCommon" Description="Alarm type common attributes. HISTORY: Added in IFC4." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcAlarm">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_0EW2q0qS4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AlarmCondition_0YAvE0qS4HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1FUqGRPvnFwwn0JFX8oyB1" Name="Pset_AlignmentCantSegmentCommon" Description="Properties common to the definition of all instances of alignment segment that have designParameters for cant." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcAlignmentSegment">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="CantDeficiency_2KWDPEjYP4_PdCs9UElsWA" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CantEquilibrium_30SDceNBr6DB9tffNjbauL" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="StartSmoothingLength_01PipsVZr9Q8Qgw9_KMfFV" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EndSmoothingLength_2EtJ89wAfDgPQfnCNoxkN6" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="16v9ITAev0LuJJYTF_fIv$" Name="Pset_AlignmentVerticalSegmentCommon" Description="Properties common to the definition of all instances of alignment vertical segment." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcAlignmentSegment">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="StartElevation_0KcYsFKoPBSh0Sikz0RXzV" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EndElevation_3OTOsjYu9DUAR5D1hN5Xdg" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0h76K0qS4HuO00025QrE$V" Name="Pset_AnnotationContourLine" Description="Specifies properties of a standard curve that has a single, consistent measure value." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcAnnotation/CONTOURLINE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ContourValue_0q3JQ0qS4HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0xpDi0qS4HuO00025QrE$V" Name="Pset_AnnotationLineOfSight" Description="Specifies the properties of the line of sight. For example, it can be used to define the line of sight visibility at the junction between two roads (particularly between an access road and a public road); or in the design of a stadium or theatre." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcAnnotation">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SetbackDistance_11mhm0qS4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VisibleAngleLeft_17k9q0qS4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VisibleAngleRight_1D5UU0qS4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RoadVisibleDistanceLeft_1Hsfk0qS4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RoadVisibleDistanceRight_1Nq7o0qS4HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1UNlG0qS4HuO00025QrE$V" Name="Pset_AnnotationSurveyArea" Description="Specifies particular properties of survey methods to be assigned to survey point set or resulting surface patches" TemplateType="pset_occurrencedriven" ApplicableEntity="IfcAnnotation/SURVEY">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="AcquisitionMethod_1Zl3w0qS4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AccuracyQualityObtained_1spmw0qS4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AccuracyQualityExpected_1ynE_0qS4HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3bHnj3jWv1hOqAd5rZoHcw" Name="Pset_ArchElementCommon" Description="Properties common to all types of _IfcArchElement_." ApplicableEntity="IfcArchElement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="InnerRadius_0BzKrHVxX7DRQKw9ZKPhnG" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OuterRadius_3xvu9UFlDF_vR3H68vBS1w" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CentroidRadius_2diev9DK90Gvau__QLo_d5" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Thickness_3HtI60qX8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsLoadBearing_1Z0YsPaSfERxoftwuOR8uQ" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3D$bUzvv10S9QdiZtidQDg" Name="Pset_ArchElementTypeSegment" Description="Properties for arch elements of type SEGMENT." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcArchElement/SEGMENT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="LongitudinalJointType_043Isdhjv28ObjidKJA1er" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RadialJointType_0Td7PHpJb2JQKm0I0w16ak" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LongitudinalJointConnections_0euxSzkhDAcfFPu$B$85Tb" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RadialJointConnections_0oSYw0FNv6_xS_Fj6q_a9u" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Mountings_0mEOFrv8f3iR74VNumT8C2" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1zs7u_JRT8ExlFtWQ5qlLW" Name="Pset_ArchElementTypeSteelRib" Description="Properties for arch elements of type _STEELRIB_." ApplicableEntity="IfcArchElement/(.STEELRIB.)">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="LongitudinalSpacing_2Fqc$pMNj5C8jRJPnj8nSC" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LongitudinalConnections_1azFwlJa58zglMh9JjImfr" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FootOfArches_2qRbpwn216hwkxu4hPpUVh" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReticularArchType_08Yo2Ip_fAMRuKPkd8Ied2" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ApertureAngle_38nOUEagv6fRIMFNX0p$i4" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BoltType_0uYUldgMH5mRcvZ37CI2wI" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BoltLength_1H5Z$T2YX1fu0c7_lXRSF8" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CorrosionTreatmentBolt_1xde67awL7Rh31mz_tzn8x" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="23KsS0qS4HuO00025QrE$V" Name="Pset_Asset" Description="An asset is a uniquely identifiable element which has a financial value and against which maintenance actions are recorded." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcAsset">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="AssetAccountingType_2AUdK0qS4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AssetTaxType_2P_Ru0qS4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AssetInsuranceType_2eHze0qS4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AssetStatus_14BbPbaD55EupvLyhdsrvG" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AssetUse_1FqkTRAnDBMPRCYYM1pIPQ" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2sbVO0qS4HuO00025QrE$V" Name="Pset_AudioVisualAppliancePHistory" Description="Captures realtime information for audio-video devices, such as for security camera footage and retail information displays. HISTORY: Added in IFC4." TemplateType="pset_performancedriven" ApplicableEntity="IfcAudioVisualAppliance">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="PowerState_2z96s0qS4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MediaSourceHistory_336aw0qS4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MediaContent_37Hcm0qS4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AudioVolumeHistory_3AsVC0qS4HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3F1X20qS4HuO00025QrE$V" Name="Pset_AudioVisualApplianceTypeAmplifier" Description="An audio-visual amplifier is a device that renders audio from a single external source connected from a port. HISTORY: Added in IFC4." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcAudioVisualAppliance/AMPLIFIER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="AmplifierType_3Nzk80qS4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AudioAmplification_3cHFu0qS4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AudioMode_3kdJa0qS4HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3vy6I0qS4HuO00025QrE$V" Name="Pset_AudioVisualApplianceTypeCamera" Description="An audio-visual camera is a device that captures video, such as for security. HISTORY: Added in IFC4." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcAudioVisualAppliance/CAMERA">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="CameraType_3_jHY0qS4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsOutdoors_0ED660qS8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VideoResolutionWidth_0JaQm0qS8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VideoResolutionHeight_0OxlQ0qS8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VideoResolutionMode_0UJ440qS8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VideoCaptureInterval_0bSqy0qS8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PanTiltZoomPreset_0jClE0qS8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PanHorizontal_0qyfW0qS8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PanVertical_0y6QO0qS8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TiltHorizontal_12g1s0qS8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TiltVertical_18dVw0qS8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Zoom_1Eaz_0qS8HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1O7KU0qS8HuO00025QrE$V" Name="Pset_AudioVisualApplianceTypeCommon" Description="An audio-visual appliance is a device that renders or captures audio and/or video. HISTORY: Added in IFC4." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcAudioVisualAppliance">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_1Xfg_0qS8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MediaSource_1n9VY0qS8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AudioVolume_1vVZE0qS8HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="21rcw0qS8HuO00025QrE$V" Name="Pset_AudioVisualApplianceTypeDisplay" Description="An audio-visual display is a device that renders video from a screen. HISTORY: Added in IFC4." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcAudioVisualAppliance/DISPLAY">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="DisplayType_28PEO0qS8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalSize_2PhVA0qS8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DisplayWidth_2WF6e0qS8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DisplayHeight_2cok60qS8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Brightness_2hZvM0qS8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ContrastRatio_2mxE00qS8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RefreshRate_2tUrU0qS8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TouchScreen_2yG0k0qS8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VideoResolutionWidth_3BlrI0qS8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VideoResolutionHeight_3IvcA0qS8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VideoResolutionMode_3Q3N20qS8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VideoScaleMode_3aBsy0qS8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VideoCaptionMode_3jkDS0qS8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AudioMode_3s4H80qS8HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3$0UE0qS8HuO00025QrE$V" Name="Pset_AudioVisualApplianceTypePlayer" Description="An audio-visual player is a device that plays stored media into a stream of audio and/or video, such as camera footage in security systems, background audio in retail areas, or media presentations in conference rooms or theatres. HISTORY: Added in IFC4." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcAudioVisualAppliance/PLAYER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="PlayerType_04zyI0qSCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PlayerMediaEject_0I5BE0qSCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PlayerMediaFormat_0Oeoi0qSCHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0YB9C0qSCHuO00025QrE$V" Name="Pset_AudioVisualApplianceTypeProjector" Description="An audio-visual projector is a device that projects video to a surface. HISTORY: Added in IFC4." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcAudioVisualAppliance/PROJECTOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ProjectorType_0ekmg0qSCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VideoResolutionWidth_0qfio0qSCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VideoResolutionHeight_0wdAs0qSCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VideoResolutionMode_11AoK0qSCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VideoScaleMode_1BJIE0qSCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VideoCaptionMode_1Krek0qSCHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0IhjJDFYoFnZx9mp0wR1Rz" Name="Pset_AudioVisualApplianceTypeRailwayCommunicationTerminal" Description="Properties used for railway communication terminals." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcAudioVisualAppliance/COMMUNICATIONTERMINAL">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="RailwayCommunicationTerminalType_33g1QhHOT0svusBGtik1jV" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1YZ140qSCHuO00025QrE$V" Name="Pset_AudioVisualApplianceTypeReceiver" Description="An audio-visual receiver is a device that switches audio and/or video from multiple sources, including external sources connected from ports and internal aggregated sources. HISTORY: Added in IFC4." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcAudioVisualAppliance/RECEIVER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReceiverType_1gIxM0qSCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AudioAmplification_1wOvK0qSCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AudioMode_23L6Q0qSCHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3osp7raMQ5ih2ElNgqb2iB" Name="Pset_AudioVisualApplianceTypeRecordingEquipment" Description="Properties common to _IfcAudioVisualAppliance_ with predefined type set to RECORDINGEQUIPMENT." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcAudioVisualAppliance/RECORDINGEQUIPMENT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfInterfaces_3D0wHuI4P3guCzHoS3Y4Zf" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="StorageCapacity_1l1lxKbmn2bAy1hWV7EsM1" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2E3lk0qSCHuO00025QrE$V" Name="Pset_AudioVisualApplianceTypeSpeaker" Description="An audio-visual speaker is a device that converts amplified audio signals into sound waves. HISTORY: Added in IFC4." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcAudioVisualAppliance/SPEAKER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SpeakerType_2KdNC0qSCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SpeakerMounting_2d5wo0qSCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SpeakerDriverSize_2uOBa0qSCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FrequencyResponse_30kFG0qSCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Impedence_37u080qSCHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3ERdc0qSCHuO00025QrE$V" Name="Pset_AudioVisualApplianceTypeTuner" Description="An audio-visual tuner is a device that demodulates a signal into a stream of audio and/or video. HISTORY: Added in IFC4." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcAudioVisualAppliance/TUNER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="TunerType_3JoyG0qSCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TunerMode_3Y6U00qSCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TunerChannel_3gSXi0qSCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TunerFrequency_3oCR_0qSCHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0UboEEXvs6sNyxn5Tkl6u6" Name="Pset_AxleCountingEquipment" Description="Properties that are applicable for IfcSensor with predefined type WHEELSENSOR, indicated that the wheel sensor is a axle counting equipment." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSensor/WHEELSENSOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="FailureInformation_30Y_YD1x1DY8_4MwqYT1kM" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DetectionRange_18tiQnmqr3a9LRMZ$sdhle" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OperationalTemperatureRange_2hvjQhIJj5c9PrmgrOQl1i" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalWeight_1NkoWVgmHA5xrENqUppTds" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AxleCountingEquipmentType_0USybSq193BewNju5coT5m" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ImpactParameter_2CaAthV3TF$xal26j2$MkZ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RatedVoltage_0_oie0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InsulationResistance_1ZlGxOxPPFmwm2gfaKJrQQ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AxleCounterResponseTime_3BJLDYF6PEFRJQcM08GUi3" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumVibration_0ZHdZ9S_zFTBfDpjz0f6mQ" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3aBgw$NhMjgrSbsXLMKZA$" Name="Pset_BalanceWeightTensionerDesignCriteria" Description="Properties of a weight tensioner. The property set can be used by the predefined type TENSIONINGEQUIPMENT of IfcDiscreteAccessory." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDiscreteAccessory/TENSIONINGEQUIPMENT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReferenceDistanceRopeToPulley_3CEvujvXv4h8b1bdTGctiY" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReferenceDistanceTensionerToGround_3xKupe5RT6XRnMcxYkd5Qt" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3vyMG0qSCHuO00025QrE$V" Name="Pset_BeamCommon" Description="Properties common to the definition of all occurrence and type objects of beam." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcBeam">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_09SAq0qSGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Span_0PY8o0qSGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Slope_0UvTS0qSGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Roll_0Zgei0qSGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsExternal_0eRpy0qSGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ThermalTransmittance_0lbaq0qSGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LoadBearing_0pmcg0qSGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FireRating_0uXnw0qSGHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3zWqDYWL5DtgyCZ5CDBDMF" Name="Pset_BearingCommon" Description="Common properties for IfcBearing." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcBearing">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="DisplacementAccommodated_3WrFcexHH7Iur_SiiVHc94" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RotationAccommodated_3HTi12lhD0vuMfKNNsFx$D" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1EA_ODQu1Bsh1498QLseM8" Name="Pset_BerthCommon" Description="Properties common to the definition of all occurrences of _IfcSpace_ and types of _IfcSpaceType_ with the predefined type set to BERTH." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSpace/BERTH,IfcSpaceType/BERTH">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="BerthApproach_1LqIMaFG1E_wM6$ISDhRBy" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BerthMode_0MTZ3yk9jEGRBp1YWiaSMb" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BerthingAngle_3y49jAM0H9uwXHrpwZiiI_" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BerthingVelocity_0lfz_btiD35xmqq3NTnBX2" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AbnormalBerthingFactor_3YCoiqGvvD0AA61M_rVW_n" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0_VF_0qSGHuO00025QrE$V" Name="Pset_BoilerPHistory" Description="Boiler performance history common attributes.
WaterQuality attribute deleted in IFC2x2 Pset Addendum: Use IfcMaterialProperties instead. CombustionProductsMaximulLoad and CombustionProductsPartialLoad attributes deleted in IFC2x2 Pset Addendum: Use IfcMaterialProperties instead." TemplateType="pset_performancedriven" ApplicableEntity="IfcBoiler">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="EnergySourceConsumption_13sae0qSGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OperationalEfficiency_17RT40qSGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CombustionEfficiency_1AQC60qSGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WorkingPressureHistory_1D$4Y0qSGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CombustionChamberTemperature_1Gzpa0qSGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PartLoadRatio_1JyYc0qSGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Load_1ML8E0qSGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PrimaryEnergyConsumption_1PJtG0qSGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AuxiliaryEnergyConsumption_1RiSu0qSGHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1VtUk0qSGHuO00025QrE$V" Name="Pset_BoilerTypeCommon" Description="Boiler type common attributes.
SoundLevel attribute deleted in IFC2x2 Pset Addendum: Use IfcSoundProperties instead. PrimaryEnergySource and AuxiliaryEnergySource attributes deleted in IFC2x2 Pset Addendum: Use IfcMaterialProperties instead." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcBoiler">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_1ephq0qSGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PressureRating_1rwwm0qSGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OperatingMode_1w5yc0qSGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HeatTransferSurfaceArea_24qbw0qSGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalPartLoadRatio_29bnA0qSGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WaterInletTemperatureRange_2Ez5q0qSGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WaterStorageCapacity_2KKQU0qSGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsWaterStorageHeater_2OVSK0qSGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PartialLoadEfficiencyCurves_2SgUA0qSGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OutletTemperatureRange_2ZqF20qSGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalEnergyConsumption_2fnj60qSGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EnergySource_2jyky0qSGHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="340A_0qSGHuO00025QrE$V" Name="Pset_BoilerTypeSteam" Description="Steam boiler type common attributes." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcBoiler/STEAM">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumOutletPressure_38BCq0qSGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalEfficiencyTable_3CMEg0qSGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HeatOutput_3Ivs80qSGHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3Q3d00qSGHuO00025QrE$V" Name="Pset_BoilerTypeWater" Description="Water boiler type common attributes." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcBoiler/WATER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalEfficiency_3UEes0qSGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HeatOutput_3aoGK0qSGHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="23CHmHZrfDlhRGsBM7Ba4q" Name="Pset_BoreholeCommon" Description="Properties describing the features of a borehole (if not modelled separately)." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcBorehole">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="BoreholeState_1VopAZOTj308bCkHC7bFi5" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CapDepth_3Gx94EXhnAxAZUYUNDKUuO" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CapMaterial_0Ccq_kkRbAMPjW5UXu8hDs" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FillingDepth_0d1eKod4HE_90bPLI3qHu4" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FillingMaterial_3uWSi7iqf6HQyEUUpQ5uip" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GroundwaterDepth_2LavVwNED3BwVZy6EdS6e4" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LiningMaterial_1McGbPCCv3Hhv0UCetKMD7" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LiningThickness_0ZvUzLlUn9gwgkgGSHJ0wI" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3zDxNhOAb5YORcsTbcKUwg" Name="Pset_BoreholeTestPressuremeter" Description="Properties for results of pressuremeter tests in boreholes." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcGeoScienceObservation/INSITUTESTRESULT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="MenardPressuremeterModulus_3QXrblA1LFxhymk$1IR2rv" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MenardLoadingUnloadingRatio_3NoxGP8K90k8Cg8dlw3vT7" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MenardLimitPressure_00Bl8r_Fv7u9veNYw6d5tJ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PressuremeterType_1y3JjznIn4hQPFaA5mCFy3" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulus_1HMLggJlb57v8ii$EHduxM" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="28LRNTfTT2gxbGTxiKCytP" Name="Pset_BoreholeTestSPT" Description="Properties for results of Standard Penetration Tests/Standard Penetrometer Tests (SPTs)." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcGeoScienceObservation/INSITUTESTRESULT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulus_1HMLggJlb57v8ii$EHduxM" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1r96WoTKj5SAJY9Bgdemep" Name="Pset_BoundedCourseCommon" Description="Properties for a bounded course." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCourse">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SpreadingRate_3zsj40KP9DfPZBUt5MVyt5" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0ucBVBF1bF8fDngXcFN_9Y" Name="Pset_BreakwaterCommon" Description="Properties common to the definition of all occurrences of _IfcMarineFacility_ with the predefined type set to BREAKWATER." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcMarineFacility/BREAKWATER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="StructuralStyle_2xjDwMs_L4qQozvzZdZkMR" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Elevation_2CNMMPOkjA69oPOt9bGTaw" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="25olP4CerBsRsGRZmhzUhG" Name="Pset_BridgeCommon" Description="Common property set for bridges." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcBridge">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="StructureIndicator_2VKNdQwen0Jf$Mx4BRfVvr" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3hy1C0qSGHuO00025QrE$V" Name="Pset_BuildingCommon" Description="Properties common to the definition of all instances of IfcBuilding. Please note that several building attributes are handled directly at the IfcBuilding instance, the building number (or short name) by IfcBuilding.Name, the building name (or long name) by IfcBuilding.LongName, and the description (or comments) by IfcBuilding.Description. Actual building quantities, like building perimeter, building area and building volume are provided by IfcElementQuantity, and the building classification according to national building code by IfcClassificationReference." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcBuilding">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BuildingID_3rUNi0qSGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsPermanentID_3wFYy0qSGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConstructionMethod_3$0kC0qSGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FireProtectionClass_03Bm20qSKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SprinklerProtection_07Mnu0qSKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SprinklerProtectionAutomatic_0C7z80qSKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OccupancyType_0GI__0qSKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossPlannedArea_0L4AE0qSKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetPlannedArea_0PFC40qSKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfStoreys_0TQDw0qSKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YearOfConstruction_0XbFm0qSKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YearOfLastRefurbishment_0cMR00qSKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsLandmarked_0gXSs0qSKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ElevationOfRefHeight_2NCeO6qW97WvcuUYvV8Wxf" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ElevationOfTerrain_0XCfx2I4T8YQefsZ57NzAZ" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0lIe60qSKHuO00025QrE$V" Name="Pset_BuildingElementProxyCommon" Description="Common properties for built elements that don&apos;t have a specific entity name." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcBuildingElementProxy">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_0w1HQ0qSKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsExternal_16YMy0qSKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ThermalTransmittance_1AjOo0qSKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LoadBearing_1EuQe0qSKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FireRating_0Jj9g0qWWHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1Nqdk0qSKHuO00025QrE$V" Name="Pset_BuildingElementProxyProvisionForVoid" Description="Properties common to the definition of a provision for void as a special type of an instance of IfcBuildingElementProxy. A provision for void is a spatial provision that might be resolved into a void in a building element. The properties carry requested values." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcBuildingElementProxy/PROVISIONFORVOID">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Shape_1Sbo_0qSKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Width_1XM_E0qSKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Height_1bY040qSKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Diameter_1fj1w0qSKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Depth_1ju3m0qSKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="System_1o35c0qSKHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1tQQG0qSKHuO00025QrE$V" Name="Pset_BuildingStoreyCommon" Description="Properties common to the definition of all instances of IfcBuildingStorey. Please note that several building attributes are handled directly at the IfcBuildingStorey instance, the building storey number (or short name) by IfcBuildingStorey.Name, the building storey name (or long name) by IfcBuildingStorey.LongName, and the description (or comments) by IfcBuildingStorey.Description. Actual building storey quantities, like building storey perimeter, building storey area and building storey volume are provided by IfcElementQuantity, and the building storey classification according to national building code by IfcClassificationReference." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcBuildingStorey">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EntranceLevel_22lC_0qSKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AboveGround_29uzs0qSKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SprinklerProtection_2GSbK0qSKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SprinklerProtectionAutomatic_0C7z80qSKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LoadBearingCapacity_2RBEe0qSKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossPlannedArea_0L4AE0qSKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetPlannedArea_0PFC40qSKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ElevationOfSSLRelative_3x5PSsV1TCdAdeFviYo34j" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ElevationOfFFLRelative_3p$gHe8S590Q5xZmxUuMwH" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2htM00qSKHuO00025QrE$V" Name="Pset_BuildingSystemCommon" Description="Properties common to the definition of building systems." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcBuildingSystem">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2u_ay0qSKHuO00025QrE$V" Name="Pset_BuildingUse" Description="Provides information on on the real estate context of the building of interest both current and anticipated." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcBuilding">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="MarketCategory_2z9co0qSKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MarketSubCategory_3374s0qSKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PlanningControlStatus_394Yw0qSKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NarrativeText_3F20_0qSKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VacancyRateInCategoryNow_3JpCE0qSKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TenureModesAvailableNow_3PAWu0qSKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MarketSubCategoriesAvailableNow_3Vk8M0qSKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RentalRatesInCategoryNow_3bhcQ0qSKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VacancyRateInCategoryFuture_3hf4U0qSKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TenureModesAvailableFuture_3n0P80qSKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MarketSubCategoriesAvailableFuture_3sztC0qSKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RentalRatesInCategoryFuture_3$Jwu0qSKHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="073rA0qSOHuO00025QrE$V" Name="Pset_BuildingUseAdjacent" Description="Provides information on adjacent buildings and their uses to enable their impact on the building of interest to be determined. Note that for each instance of the property set used, where there is an existence of risk, there will be an instance of the property set Pset_Risk (q.v)." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcBuilding">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="MarketCategory_0BEt00qSOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MarketSubCategory_0GcBg0qSOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PlanningControlStatus_0MZfk0qSOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NarrativeText_0SX7o0qSOHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0P5PgQe5XA1Rk37$BdUJdH" Name="Pset_BuiltElementCommon" Description="$" ApplicableEntity="IfcBuildingElement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsExternal_3wicPbQZz5Ru6Zjj9F$4Lp" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LoadBearing_1wZ5bqss58mx9mYZdud_ti" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FireRating_1_Wi5CzOTB$eL7qP2aEEGc" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ThermalTransmittance_0W$kQiRJjCzwqrvSp47kdg" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="29lvyP2sPD4gVVxzj4Lny5" Name="Pset_BuiltSystemRailwayLine" Description="Properties common to the definition of a railway line system, which is a set of functional tracks with explicit terminals. It is usually composed of a set of tracks with continuous track parts and alignments." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcBuiltSystem/RAILWAYLINE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="LineID_1LQ0XPbITCVe8zQJfs9vuz" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsElectrified_3fjp6BiNH8WQOXnO69XO80" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LineCharacteristic_3_0m4qnAT5ZOLLtwRg$XmV" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3PJwyKeDJNZ_U5UPbCxKHT" Name="Pset_BuiltSystemRailwayTrack" Description="Properties common to the definition of a track system. It is usually composed of continuous sequences of track parts and alignments." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcBuiltSystem/RAILWAYTRACK">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="TrackID_1QUq47Cd5EufPArQiLv0RG" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TrackNumber_04f6CUpMXA8hZooEXNRWkz" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TrackUsage_259p5P3E16WRyNXgledf39" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TrackCharacteristic_0usHrhLiDDNf8Mimwaruzl" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3wgT2KSiT8bfBOPweBSIoc" Name="Pset_BuiltSystemTypeWaterproofing" Description="Properties for waterproofing systems." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcBuiltSystem/WATERPROOFING">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="WaterproofingSystem_3$algbaZDFJPwTAD8YkBcA" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WatertightnessClassification_3o5MfIEcL6VubC3CVWfHTs" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0YUbs0qSOHuO00025QrE$V" Name="Pset_BurnerTypeCommon" Description="Common attributes of burner types." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcBurner">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_0jDFA0qSOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EnergySource_2jyky0qSGHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1NXh00qSOHuO00025QrE$V" Name="Pset_CableCarrierFittingTypeCommon" Description="Common properties for cable carrier fittings. HISTORY: Added in IFC4." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCableCarrierFitting">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_1XgAw0qSOHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1oMII0qSOHuO00025QrE$V" Name="Pset_CableCarrierSegmentTypeCableLadderSegment" Description="An open carrier segment on which cables are carried on a ladder structure.
HISTORY: IFC4 - NominalLength deleted. To be handled as a quantity measure." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCableCarrierSegment/CABLELADDERSEGMENT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="LadderConfiguration_232Pg0qSOHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2ACAY0qSOHuO00025QrE$V" Name="Pset_CableCarrierSegmentTypeCableTraySegment" Description="An (typically) open carrier segment onto which cables are laid.
HISTORY: IFC4 - NominalLength deleted. To be handled as a quantity measure" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCableCarrierSegment/CABLETRAYSEGMENT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasCover_2Ph$60qSOHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2Wrl_0qSOHuO00025QrE$V" Name="Pset_CableCarrierSegmentTypeCableTrunkingSegment" Description="An enclosed carrier segment with one or more compartments into which cables are placed.
HISTORY: IFC4 - NominalLength deleted. To be handled as a quantity measure" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCableCarrierSegment/CABLETRUNKINGSEGMENT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfCompartments_2mxjy0qSOHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3UI9dqTovFpUlucIdwHX5Z" Name="Pset_CableCarrierSegmentTypeCatenaryWire" Description="Properties of a catenary wire, which is a longtitudinal wire supporting the grooved contact wires. Properties in this property set are applicable to a type or an occurrence _ifcCableCarrierSegment_ with predefined type of CATENARYWIRE." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCableCarrierSegment/CATENARYWIRE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ACResistance_2$dT1WHiH7Ge2PeqXa73Sp" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UltimateTensileStrength_0eJN7IDD15sBhRJRd4TjCU" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CatenaryWireType_33lc5OXGT9FexvS$tyrx03" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ThermalExpansionCoefficient_2BAG20qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CurrentCarryingCapacity_2bRJDYSdX00x51ZO5f_6Kl" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DCResistance_1iHsZExLz0_hKDmfStAwc4" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LayRatio_1LJW3Nv3XFAwnt7PZuIg3n" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MassPerLength_1bxC00qVOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MechanicalTension_0NjLrbe5v3zuECrs8qsUAO" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PhysicalDescriptionReference_1KBMgHLx5B9BVSKUJEHSi9" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="StrandingMethod_3LKqUANgv49RHlqIkKEDH9" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TensileStrength_1ZuJdL4cPBOuLWEzKCV5K4" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulus_1x4I40qUqHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2tVLQ0qSOHuO00025QrE$V" Name="Pset_CableCarrierSegmentTypeCommon" Description="Common properties for cable carrier segments. HISTORY: Added in IFC4." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCableCarrierSegment">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_31drK0qSOHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3JWFW0qSOHuO00025QrE$V" Name="Pset_CableCarrierSegmentTypeConduitSegment" Description="An enclosed tubular carrier segment through which cables are pulled.
HISTORY: IFC4 - NominalLength deleted. To be handled as a quantity measure." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCableCarrierSegment/CONDUITSEGMENT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalHeight_3VRBe0qSOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConduitShapeType_3b_p60qSOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsRigid_3qIKs0qSOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalDiameter_2EWhC0qX8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalWidth_2YZfyYRY1Aa9bsWGvZEaNq" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1ptdTcmDieglesy8J2SD0U" Name="Pset_CableCarrierSegmentTypeDropper" Description="Properties that are applicable to a type or an occurrence of dropper." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCableCarrierSegment/DROPPER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="CurrentCarryingCapacity_2bRJDYSdX00x51ZO5f_6Kl" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TensileStrength_1ZuJdL4cPBOuLWEzKCV5K4" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AssemblyInstruction_3W5i6nbkP9NBt_M6PTB5jW" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsRigid_3qIKs0qSOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UltimateTensileStrength_0eJN7IDD15sBhRJRd4TjCU" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsAdjustable_00OvkE_Rn4KBS$xE3fF5xV" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsCurrentCarrying_2T0h_sw_H3s8fsIzbCjbLk" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalLoad_2dKB03DRb7Wg298fNHgJuO" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3xS5k0qSOHuO00025QrE$V" Name="Pset_CableFittingTypeCommon" Description="Common properties for cable fittings. HISTORY: Added in IFC4." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCableFitting">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_05abe0qSSHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1ttBG8y2fkk0WyM382QM5$" Name="Pset_CableFittingTypeExit" Description="Properties of the exit type of cable fitting which ends a cable segment at a non-electric element." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCableFitting/EXIT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GroundResistance_2NdoXdKT98XeEMmk8dSBQF" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1_xKtguhcJaSig0Wp199h8" Name="Pset_CableFittingTypeFanout" Description="Properties of the fanout type of cable fitting." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCableFitting/FANOUT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfTubes_3UkslSzBr10gMXXud95Exh" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TubeDiameter_2$VL9j18b63QdizLrkdfFs" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1o0FJEnVz8XuOt6Bt1ySyR" Name="Pset_CableSegmentConnector" Description="Properties about cable connectors. This property set is applicable to a type or occurence of _IfcCableSegment_, indicated that the cable segment has one or two connectors affiliated." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCableSegment">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConnectorAColour_0w0gEEc0zFjvNswSrKmDQ$" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConnectorBColour_1cThVIaMXEcAEobfXJFIPy" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConnectorAType_05lh3wrjD3fe$BEp5kTIqH" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConnectorBType_2xjdteWAjCdRxhbBMzx0M0" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConnectorAGender_3yUsi5u7T4BQGLpkunPPI0" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConnectorBGender_3iBqO$VGP8tOJhBPjhmLpB" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0$kPsI_NR39__u_tVrQafA" Name="Pset_CableSegmentOccurenceFiberSegment" Description="Properties of fiber segment occurrences. This property set is applicable to occurences of _IfcCableSegment_ with predefined type FIBERSEGMENT." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcCableSegment/FIBERSEGMENT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="InUse_0KMEUwmITB4x_YwcSfAiOX" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2B2OU6K4r3mxn0CyZEpEvj" Name="Pset_CableSegmentOccurrence" Description="Properties for the occurrence of an electrical cable, core or conductor that conforms to a type as specified by an appropriate type definition within IFC. NOTE: Maximum allowed voltage drop should be derived from the property within Pset_ElectricalCircuit." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcCableSegment">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="DesignAmbientTemperature_1L_xLZOQ911A3ajJsEJF$L" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UserCorrectionFactor_3PfRv5G3bD8ejiLpHnvnyY" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfParallelCircuits_1AWABiyr1Fnhe$8ZNYyby4" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InstallationMethod_1y3E9FdGDDcuFQAiNae6DC" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InstallationMethodFlagEnum_2_Nz3RdYDAXBJWTsAWu6NX" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DistanceBetweenParallelCircuits_2NVHp9_FL8tAeZWWe_dGTq" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SoilConductivity_0sP2Zz6UL4Lw4ArbLa1rZd" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CarrierStackNumber_1waNpZNY9ArOqUXxmsLi6u" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MountingMethod_0IM4Q99JP0aPIH_odNLQo2" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsHorizontalCable_3Kx2SOOpDE7gZDqQ7MF7S8" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsMountedFlatCable_0cChT80zD6mAhzFtp$7usP" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CurrentCarryingCapacity_2bRJDYSdX00x51ZO5f_6Kl" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumCableLength_2W2E0jVrH8CuFa_0QTtWyt" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PowerLoss_17rkswZN5Ayh1V1zbea9$s" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SequentialCode_1rZx8VDW987QxAxZ64yNea" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0O39E0qSSHuO00025QrE$V" Name="Pset_CableSegmentTypeBusBarSegment" Description="Properties specific to busbar cable segments." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCableSegment/BUSBARSEGMENT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsHorizontalBusbar_0U0dI0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalCurrent_0sDhk0qUWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UltimateTensileStrength_0eJN7IDD15sBhRJRd4TjCU" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ACResistance_2$dT1WHiH7Ge2PeqXa73Sp" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ThermalExpansionCoefficient_2BAG20qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CurrentCarryingCapacity_2bRJDYSdX00x51ZO5f_6Kl" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DCResistance_1iHsZExLz0_hKDmfStAwc4" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MassPerLength_1bxC00qVOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TensileStrength_1ZuJdL4cPBOuLWEzKCV5K4" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulus_1x4I40qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CrossSectionalArea_0gEm60qSWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InsulationMethod_1_Ub8uyHX2dgCLYmh2_Ttw" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OverallDiameter_0urEa0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OperationalTemperatureRange_2_eMO0qS0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RatedVoltage_1uw9k0qSWHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0bAOA0qSSHuO00025QrE$V" Name="Pset_CableSegmentTypeCableSegment" Description="Electrical cable with a specific purpose to lead electric current within a circuit or any other electric construction. Includes all types of electric cables, mainly several electrical segments wrapped together, e.g. cable, tube, busbar. Note that the number of conductors within a cable is determined by an aggregation mechanism that aggregates the conductors within the cable. A single-core cable is defined in IEV 461-06-02 as being &apos;a cable having only one core&apos;; a multiconductor cable is defined in IEV 461-06-03 as b eing &apos;a cable having more than one conductor, some of which may be uninsulated&apos;; a mulicore cable is defined in IEV 461-06-04 as being &apos;a cable having more than one core&apos;." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCableSegment/CABLESEGMENT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Standard_0h7sE0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfCores_0n5KI0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OverallDiameter_0urEa0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RatedTemperature_14mAi0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ScreenDiameter_1Ajem0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasProtectiveEarth_1P1AW0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumOperatingTemperature_1juJk0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumShortCircuitTemperature_1$AaW0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SpecialConstruction_27WeC0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Weight_2EgP40qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SelfExtinguishing60332_1_2JRaK0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SelfExtinguishing60332_3_2PP2O0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HalogenProof_2Vyfs0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FunctionReliable_2bJ_W0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ACResistance_2$dT1WHiH7Ge2PeqXa73Sp" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CurrentCarryingCapacity_2bRJDYSdX00x51ZO5f_6Kl" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DCResistance_1iHsZExLz0_hKDmfStAwc4" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MassPerLength_1bxC00qVOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumCurrent_0w_s_0qUWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumBendingRadius_0lxvCy45jAwx0T2d$IauLd" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfWires_2vNnC4jfb7dgwh_lRMrBkU" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InsulationVoltage_0bnlOizRrA7828DVf4FSKA" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RatedVoltage_1uw9k0qSWHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2htb_0qSSHuO00025QrE$V" Name="Pset_CableSegmentTypeCommon" Description="Properties for the definitions of electrical cable segments." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCableSegment">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_2qpp40qSSHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0atRS0qSWHuO00025QrE$V" Name="Pset_CableSegmentTypeConductorSegment" Description="An electrical conductor is a single linear element with the specific purpose to lead electric current. The core of one lead is normally single wired or multiwired which are intertwined. According to IEC 60050: IEV 195-01-07, a conductor is a conductive part intended to carry a specified electric current." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCableSegment/CONDUCTORSEGMENT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="CrossSectionalArea_0gEm60qSWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Function_0moNa0qSWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConductorMaterial_10uLY0qSWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Construction_1CpHg0qSWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConductorShape_1PwWc0qSWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalCurrent_0sDhk0qUWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ACResistance_2$dT1WHiH7Ge2PeqXa73Sp" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ThermalExpansionCoefficient_2BAG20qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CurrentCarryingCapacity_2bRJDYSdX00x51ZO5f_6Kl" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UltimateTensileStrength_0eJN7IDD15sBhRJRd4TjCU" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MassPerLength_1bxC00qVOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TensileStrength_1ZuJdL4cPBOuLWEzKCV5K4" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulus_1x4I40qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DCResistance_1iHsZExLz0_hKDmfStAwc4" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OverallDiameter_0urEa0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfCores_0n5KI0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RatedVoltage_1uw9k0qSWHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1YjUDxeJO1UI$t60LxenT$" Name="Pset_CableSegmentTypeContactWire" Description="Properties of contact wires used in overhead contact line systems. This property set is applicable to a type or occurrence of _IfcCableSegment_ with predefined type CONTACTWIRESEGMENT." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCableSegment/CONTACTWIRESEGMENT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ACResistance_2$dT1WHiH7Ge2PeqXa73Sp" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ThermalExpansionCoefficient_2BAG20qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CurrentCarryingCapacity_2bRJDYSdX00x51ZO5f_6Kl" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DCResistance_1iHsZExLz0_hKDmfStAwc4" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MassPerLength_1bxC00qVOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulus_1x4I40qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CrossSectionalArea_0gEm60qSWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TorsionalStrength_0S_uq2KWrCDQRWW5W4PUOa" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TensileStrength_1ZuJdL4cPBOuLWEzKCV5K4" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1jbN00qSWHuO00025QrE$V" Name="Pset_CableSegmentTypeCoreSegment" Description="An assembly comprising a conductor with its own insulation (and screens if any)" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCableSegment/CORESEGMENT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="OverallDiameter_1oyhg0qSWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RatedVoltage_1uw9k0qSWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RatedTemperature_1$TnC0qSWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoreIdentifier_2Cb080qSWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ScreenDiameter_1Ajem0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SheathColours_2IYUC0qSWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Weight_2nY7K0qSWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UltimateTensileStrength_0eJN7IDD15sBhRJRd4TjCU" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SelfExtinguishing60332_1_2sJIa0qSWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SelfExtinguishing60332_3_2xgdE0qSWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HalogenProof_311xu0qSWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FunctionReliable_2bJ_W0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Standard_0h7sE0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ThermalExpansionCoefficient_2BAG20qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CurrentCarryingCapacity_2bRJDYSdX00x51ZO5f_6Kl" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DCResistance_1iHsZExLz0_hKDmfStAwc4" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LayRatio_1LJW3Nv3XFAwnt7PZuIg3n" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MassPerLength_1bxC00qVOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TensileStrength_1ZuJdL4cPBOuLWEzKCV5K4" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulus_1x4I40qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ACResistance_2$dT1WHiH7Ge2PeqXa73Sp" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="StrandingMethod_3LKqUANgv49RHlqIkKEDH9" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1XywgPBLBsJdhXFgekf6UF" Name="Pset_CableSegmentTypeEarthingConductor" Description="Properties of earthing conductors used in overhead contact line systems. This property set is applicable to a type or occurence of _IfcCableSegment_ with predefined type CONDUCTORSEGMENT." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCableSegment/CONDUCTORSEGMENT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ResistanceToGround_2cjcL0mEjDXPYwqZazv4A9" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="11zk8ID5H3$IAQQEHVr2Nt" Name="Pset_CableSegmentTypeFiberSegment" Description="Properties of fiber segments. This property set is applicable to a type or occurence of _IfcCableSegment_ with predefined type FIBERSEGMENT." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCableSegment/FIBERSEGMENT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="FiberColour_1HeG7B2WPEjBPpFB1rwWJ_" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasTightJacket_1aoZzRJGjFAuxNIGdeSy5m" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FiberType_33hW6SI9L88u4r9StkBaiz" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2_fHVOZ3rFCg8JQ7Ujpx3c" Name="Pset_CableSegmentTypeFiberTubeSegment" Description="Properties of Fiber tubes segments. This property set is applicable to a type or occurence of _IfcCableSegment_ with predefined type FIBERTUBESEGMENT." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCableSegment/FIBERTUBE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="FiberTubeColour_3m0FdinCDDhAUaT$zdvYyG" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfFibers_0ql_hsVrT7ZeyOizbL_4bp" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2y6G_WaGiFBm5uXfKGEJBH" Name="Pset_CableSegmentTypeOpticalCableSegment" Description="Properties of optical cables segments. This property set is applicable to a type or occurence of _IfcCableSegment_ with predefined type OPTICALCABLESEGMENT." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCableSegment/OPTICALCABLESEGMENT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfFibers_0ql_hsVrT7ZeyOizbL_4bp" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OpticalCableStructure_3lG57$HT1009UobXR$iHbV" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfMultiModeFibers_21mdZfn9X5PwPW4Q$QPfW$" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfSingleModeFibers_02lNFVtbrDlhiARV8DGc6Z" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfTubes_3UkslSzBr10gMXXud95Exh" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FiberMode_0_QAybmkz5UQ9pCD5EbZDf" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3DPe4Z1lrNZ2x32leTdGJN" Name="Pset_CableSegmentTypeStitchWire" Description="Properties of stitch wires. This property set is applicable to a type or occurrence of _IfcCableSegment_ with predefined type STICHWIRE." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCableSegment/STITCHWIRE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="AssemblyInstruction_3W5i6nbkP9NBt_M6PTB5jW" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalLength_0NS18P1J51kRFniH3h5CIL" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MechanicalTension_0NjLrbe5v3zuECrs8qsUAO" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UltimateTensileStrength_0eJN7IDD15sBhRJRd4TjCU" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TensileStrength_1ZuJdL4cPBOuLWEzKCV5K4" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="23RWfrWBNKEmpDYItQpcmx" Name="Pset_CableSegmentTypeWirePairSegment" Description="Properties of wire pair segments. This property set is applicable to a type or occurrence of _IfcCableSegment_ with predefined type WIREPAIRSEGMENT." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCableSegment/WIREPAIRSEGMENT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="CharacteristicImpedance_10mgUNnHf1VfAg7w_L3oMi" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConductorDiameter_2LgQvvudb6UBQkAzoEIL3k" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoreConductorDiameter_3ZwqVh2H99qOG$$4R$j3QX" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="JacketColour_1vHztIiLn2ZvG$H5JLPMVP" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShieldConductorDiameter_1as$loCX107Pk6vf9GXkJu" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WirePairType_3VzXtlphv2zPqieA4Gh1SM" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3CozvThg9ENQLQTWA77IQ7" Name="Pset_CargoCommon" Description="Properties common to the definition of all occurrences of _IfcTransportElement_ and types of _IfcTransportElementType_ with the predefined type set to CARGO." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcVehicle/CARGO">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ProcessItem_0yXM2dwTn71gpxHeftzb$S" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AdditionalProcessing_0GPWZ5EWD53Rg3vsFDWGkS" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ProcessDirection_0_iuQ9laT8WBnP5Q4o04AH" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3hIvAY4_nIO5x900DEA7fz" Name="Pset_CessBetweenRails" Description="Properties in this property set are applicable for IfcSlab with PredefinedType TRACKSLAB, indicated that the slab is a cess or covering between rails." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSlab/TRACKSLAB">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="JointRelativePosition_06BnzJB6b9zhMKCUAtPkfJ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CheckRailType_2JexmLPDX5sBsONo7e2qsk" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LoadCapacity_1_J9Z6hsjADva_RGdwfJlg" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UsagePurpose_1fZSkvX5HFxP0_mPJtSZjB" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3IwM40qSWHuO00025QrE$V" Name="Pset_ChillerPHistory" Description="Chiller performance history attributes." TemplateType="pset_performancedriven" ApplicableEntity="IfcChiller">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Capacity_3Otq80qSWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EnergyEfficiencyRatio_3RsZA0qSWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoefficientOfPerformance_3W1b00qSWHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3aCcs0qSWHuO00025QrE$V" Name="Pset_ChillerTypeCommon" Description="Chiller type common attributes." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcChiller">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_3lXPa0qSWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ChillerCapacity_3_R4k0qSWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalEfficiency_04OYo0qSaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalCondensingTemperature_099k20qSaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalEvaporatingTemperature_0EX2i0qSaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalHeatRejectionRate_0KUWm0qSaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalPowerConsumption_0PrrQ0qSaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CapacityCurve_0Ud0g0qSaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoefficientOfPerformanceCurve_0dZDm0qSaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FullLoadRatioCurve_0lvHS0qSaHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0urUY0qSaHuO00025QrE$V" Name="Pset_ChimneyCommon" Description="Properties common to the definition of all occurrence and type objects of chimneys." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcChimney">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_16Ysu0qSaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfDrafts_1NE_G0qSaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsExternal_1ScIw0qSaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ThermalTransmittance_1Xzda0qSaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LoadBearing_1dKyE0qSaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FireRating_1iiGu0qSaHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2QshPSbtHEWeYz4t$IJ_5k" Name="Pset_CivilElementCommon" Description="Properties common to the definition of all occurrence and type objects of civil element." ApplicableEntity="IfcCivilElement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_0CKeiSTML5V8Nk6QNncdRn" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2Twei8EELABDfBuEHG693$" Name="Pset_CoaxialCable" Description="Properties applicable to a coaxial cable, which is a copper cable with a variable number of copper coaxial pair conductors used to transmit data by means of electrical signals, especially at radio frequency. This property set is applicable to a type or occurence of _IfcCableSegment_ with predefined type CABLESEGMENT." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCableSegment/CABLESEGMENT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="CharacteristicImpedance_10mgUNnHf1VfAg7w_L3oMi" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CouplingLoss_1xcHAeM5z0ie3RUCZRUAl0" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumTransmissionAttenuation_0v_sIcbmP5qfPydldRrfEw" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfCoaxialPairs_38Z$45A$fEjAEjKJ1e9ONe" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PropagationSpeedCoefficient_0AK8i5JmXDxfWTbSTJ3n91" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TransmissionLoss_3JHZdLDLfCYhcj9wzSDlXu" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RadiantFrequency_1TRSUYI_166AUFrlaZw$TZ" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1ps1m0qSaHuO00025QrE$V" Name="Pset_CoilOccurrence" Description="Coil occurrence attributes attached to an instance of IfcCoil." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcCoil">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasSoundAttenuation_1udD00qSaHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1$AqU0qSaHuO00025QrE$V" Name="Pset_CoilPHistory" Description="Coil performance history common attributes.
Sound attribute deleted in IFC2x2 Pset Addendum: Use IfcSoundProperties instead." TemplateType="pset_performancedriven" ApplicableEntity="IfcCoil">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="AtmosphericPressure_24Y980qSaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AirPressureDropCurveHistory_27WuA0qSaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SoundCurveHistory_2B5mc0qSaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FaceVelocity_2E4Ve0qSaHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2Irgu0qSaHuO00025QrE$V" Name="Pset_CoilTypeCommon" Description="Coil type common attributes." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCoil">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_2Umd00qSaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OperationalTemperatureRange_2j48m0qSaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AirFlowRateRange_2qq320qSaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalSensibleCapacity_2xNgW0qSaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalLatentCapacity_308rm0qSaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalUA_35WAQ0qSaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoilPlacement_39hCG0qSaHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3OatQ0qSaHuO00025QrE$V" Name="Pset_CoilTypeHydronic" Description="Hydronic coil type attributes." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCoil">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="FluidPressureRange_3S9ls0qSaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoilCoolant_3XX4W0qSaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoilConnectionDirection_3keJS0qSaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoilFluidArrangement_3zX_c0qSaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoilFaceArea_0BFMy0qSeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HeatExchangeSurfaceArea_0Gchc0qSeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PrimarySurfaceArea_0L_0G0qSeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SecondarySurfaceArea_0QlBW0qSeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TotalUACurves_0cg7e0qSeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WaterPressureDropCurve_0l0BK0qSeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BypassFactor_0tMF00qSeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SensibleHeatRatio_0yjZg0qSeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WetCoilFraction_12h1k0qSeHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1AQy00qSeHuO00025QrE$V" Name="Pset_ColumnCommon" Description="Properties common to the definition of all occurrence and type objects of column." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcColumn">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_1QWv_0qSeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Slope_1hpAm0qSeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Roll_1nmeq0qSeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsExternal_1tk6u0qSeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ThermalTransmittance_1yVI80qSeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LoadBearing_21GTO0qSeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FireRating_0eTJm0qT0HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2DBPW0qSeHuO00025QrE$V" Name="Pset_CommunicationsAppliancePHistory" Description="Captures realtime information for communications devices, such as for server farm energy usage. HISTORY: Added in IFC4." TemplateType="pset_performancedriven" ApplicableEntity="IfcCommunicationsAppliance">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="PowerState_2GmHy0qSeHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1thMzNtIwb$dzhJUfjV7Sw" Name="Pset_CommunicationsApplianceTypeAntenna" Description="Properties common to an antenna. This property set is applied to a type or occurrence of _IfcCommunicationsAppliance_ with the predefined type ANTENNA." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCommunicationsAppliance/ANTENNA">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="AntennaGain_3tDqS6zLnDv8qs_AhvaVI1" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PolarizationMode_0xnVcngeL0puq0IO2aWcNm" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RadiationPattern_0KBK4$FZP5memrgigaPaRn" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AntennaType_31c4VZLhD5Ve8keYZDr8ce" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2iYwWkqvu1XAXM_ZLi4n$c" Name="Pset_CommunicationsApplianceTypeAutomaton" Description="Properties common to automaton appliances. This property set is applied to a type or occurrence of _IfcCommunicationsAppliance_ with predefined type of AUTOMATON." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCommunicationsAppliance/AUTOMATON">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="InputSignalType_3mt7oNhWL3QuPz1Q2ybJCo" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OutputSignalType_2TKPRtqQfDlgGubE0HD4kt" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2KxJo0qSeHuO00025QrE$V" Name="Pset_CommunicationsApplianceTypeCommon" Description="Common properties for communications appliances. HISTORY: Added in IFC4." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCommunicationsAppliance">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_2Vfz60qSeHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2lbRkr0zQOlM3PVKC6a8Vl" Name="Pset_CommunicationsApplianceTypeComputer" Description="Properties common to a computer. This property set is applied to a type or occurrence of _IfcCommunicationsAppliance_ with predefined type of COMPUTER." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCommunicationsAppliance/COMPUTER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="StorageCapacity_1$iZi7fOT5d8x0ECyuS0B0" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UserInterfaceType_2vSpfYCJv1kBISUSIgQtwO" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="158Qqo0HeddapqCQKHHFw1" Name="Pset_CommunicationsApplianceTypeGateway" Description="Properties common to a gateway. This property set is applied to a type or occurrence of _IfcCommunicationsAppliance_ with predefined type of GATEWAY." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCommunicationsAppliance/GATEWAY">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfInterfaces_3D0wHuI4P3guCzHoS3Y4Zf" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1y3mhYYUglyebURQtI1TUM" Name="Pset_CommunicationsApplianceTypeIntelligentPeripheral" Description="Properties common to a intelligent peripheral. This property set is applied to a type or occurrence of _IfcCommunicationsAppliance_ with predefined type of INTELLIGENT_PERIPHERAL." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCommunicationsAppliance/INTELLIGENTPERIPHERAL">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="UserCapacity_2eXzZatEr5bOQ1ApLLVBvv" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0AUNbrd5guo7$_Si9pnZIg" Name="Pset_CommunicationsApplianceTypeIpNetworkEquipment" Description="Properties common to a IP network equipment. This property set is applied to a type or occurrence of _IfcCommunicationsAppliance_ with predefined type of IP_NETWORK_EQUIPMENT." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCommunicationsAppliance/IPNETWORKEQUIPMENT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfSlots_3ol50yqfz8ZAv5ApU0vpo5" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EquipmentCapacity_37sz88SXT3JOvbrpAb4kbe" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfCoolingFans_2RNxHeP9b8vBeh97YG_WtE" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SupportedProtocol_0KTh8eeFPDFuFrZpvLZpBP" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ManagingSoftware_3aRmeqOcHEwhPmdUx1o9wR" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfInterfaces_3D0wHuI4P3guCzHoS3Y4Zf" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1g1KR9_kgRn0tdXmaoNnje" Name="Pset_CommunicationsApplianceTypeModem" Description="Properties common to a modem. This property set is applied to a type or occurrence of _IfcCommunicationsAppliance_ with predefined type MODEM." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCommunicationsAppliance/MODEM">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfCommonInterfaces_1DWcqAjZr43OGGCJpgy1j6" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfTrafficInterfaces_09Z_XNzNLBnwwViB8ciE59" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CommonInterfaceType_3Xuwkh7UD9wuLX4uBTrvQ8" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TrafficInterfaceType_3HwCkdfrL8cRT34SaMeiGY" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1T4UINgrEfAs6eYbIX5JMp" Name="Pset_CommunicationsApplianceTypeOpticalLineTerminal" Description="Properties common to a optical line terminal. This property set is applied to a type or occurrence of _IfcCommunicationsAppliance_ with predefined type OPTICALLINETERMINAL." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCommunicationsAppliance/OPTICALLINETERMINAL">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfSlots_3ol50yqfz8ZAv5ApU0vpo5" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfInterfaces_3D0wHuI4P3guCzHoS3Y4Zf" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1Qow3jpcp$TBM45huFXC6s" Name="Pset_CommunicationsApplianceTypeOpticalNetworkUnit" Description="Properties common to a optical network unit. This property set is applied to a type or occurrence of _IfcCommunicationsAppliance_ with predefined type OPTICAL_NETWORK_UNIT." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCommunicationsAppliance/OPTICALNETWORKUNIT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="OpticalNetworkUnitType_3MqyyGk_v15RyXHBF73XE8" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfInterfaces_3D0wHuI4P3guCzHoS3Y4Zf" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="080b2VQlmd8tVVEyEhRdT2" Name="Pset_CommunicationsApplianceTypeTelecommand" Description="Properties common to a telecommand. This property set is applied to a type or occurrence of _IfcCommunicationsAppliance_ with predefined type TELECOMMAND." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCommunicationsAppliance/TELECOMMAND">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfWorkstations_1NteTJwCTDPxZ$71U8R760" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfCPUs_1rjaY2H_LBUB1VPn5lebft" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0aqb1B326mnio9NjHIvdOf" Name="Pset_CommunicationsApplianceTypeTelephonyExchange" Description="Properties common to a telephony exchange. This property set is applied to a type or occurrence of _IfcCommunicationsAppliance_ with predefined type TELEPHONYEXCHANGE." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCommunicationsAppliance/TELEPHONYEXCHANGE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="UserCapacity_2eXzZatEr5bOQ1ApLLVBvv" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="267ErBq$$KykFgax3JjaSN" Name="Pset_CommunicationsApplianceTypeTransportEquipment" Description="Properties common to a transport equipment. This property set is applied to a type or occurrence of _IfcCommunicationsAppliance_ with predefined type TRANSPORTEQUIPMENT." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCommunicationsAppliance/TRANSPORTEQUIPMENT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsUpgradable_2ZU8jJnSr22RzVeas8FkPD" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ElectricalCrossCapacity_0quq4gG9n9tv6gtXkQaQ$F" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfSlots_3ol50yqfz8ZAv5ApU0vpo5" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TransportEquipmentType_1O7IGaCufAmeb1bIq4Z1FV" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TransportEquipmentAssemblyType_2rlIrmbVH6IhlLGvYDFRI_" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3JWlS0qSeHuO00025QrE$V" Name="Pset_CompressorPHistory" Description="Compressor performance history attributes." TemplateType="pset_performancedriven" ApplicableEntity="IfcCompressor">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="CompressorCapacity_3Q4Mw0qSeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EnergyEfficiencyRatio_3T35y0qSeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoefficientOfPerformance_3W1b00qSWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VolumetricEfficiency_3aCsq0qSeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CompressionEfficiency_3dBbs0qSeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MechanicalEfficiency_3gAKu0qSeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsentropicEfficiency_3j93w0qSeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CompressorTotalEfficiency_3mjyM0qSeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShaftPower_3qu_C0qSeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InputPower_3uTse0qSeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LubricantPumpHeatGain_3y2l40qSeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FrictionHeatGain_3$1U60qSeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CompressorTotalHeatGain_020D80qSiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FullLoadRatio_05b5a0qSiHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0AMGq0qSiHuO00025QrE$V" Name="Pset_CompressorTypeCommon" Description="Compressor type common attributes." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCompressor">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_0L4w80qSiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PowerSource_0dZTk0qSiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RefrigerantClass_0sT8u0qSiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MinimumPartLoadRatio_1Ditk0qSiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumPartLoadRatio_1J4CO0qSiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CompressorSpeed_1NrNe0qSiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalCapacity_1Tori0qSiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IdealCapacity_1aMTA0qSiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IdealShaftPower_1hWE20qSiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasHotGasBypass_1mtYi0qSiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ImpellerDiameter_1sr0m0qSiHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1$B4S0qSiHuO00025QrE$V" Name="Pset_ConcreteElementGeneral" Description="General properties common to different types of concrete elements, including reinforced concrete elements. The property set can be used by a number of subtypes of IfcBuiltElement, indicated that such element is designed or constructed using a concrete construction method." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcBeam,IfcBuildingElementProxy,IfcChimney,IfcColumn,IfcFooting,IfcMember,IfcPile,IfcPlate,IfcRailing,IfcRamp,IfcRampFlight,IfcRoof,IfcSlab,IfcStair,IfcStairFlight,IfcWall,IfcCivilElement,IfcArchElement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="AssemblyPlace_1YL3k0qUmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CastingMethod_1xR8kP0en6N86AGgIaUR$s" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="StructuralClass_24YP60qSiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="StrengthClass_2MEGt4G$r1s8oshAXjpacJ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ExposureClass_2RxWltAjDAPhxrUt6toXTR" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReinforcementVolumeRatio_2XmEU5oRn1XutRnd$G$pqc" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReinforcementAreaRatio_03QJXaBBz9ugaDD64qh7Hr" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DimensionalAccuracyClass_2akL20qSiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConstructionToleranceClass_2hu5w0qSiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConcreteCover_07PBZZQdn2TOMV5JJgFkm9" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConcreteCoverAtMainBars_2u$Ks0qSiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConcreteCoverAtLinks_2_yow0qSiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReinforcementStrengthClass_2uZA8bB4j05BpoYRkzMMEO" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReinforcementType_2$OfGxKXj3x8NK_1AVp3LA" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1Okjk0qSmHuO00025QrE$V" Name="Pset_CondenserPHistory" Description="Condenser performance history attributes." TemplateType="pset_performancedriven" ApplicableEntity="IfcCondenser">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="HeatRejectionRate_1VuUc0qSmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ExteriorHeatTransferCoefficient_1a3WS0qSmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InteriorHeatTransferCoefficient_1deOu0qSmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RefrigerantFoulingResistance_1hpQk0qSmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CondensingTemperature_1ko9m0qSmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LogarithmicMeanTemperatureDifference_1ozBc0qSmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UAcurves_1sY420qSmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CompressorCondenserHeatGain_1w6yU0qSmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CompressorCondenserPressureDrop_1zhqw0qSmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CondenserMeanVoidFraction_21GjM0qSmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WaterFoulingResistance_24rbo0qSmHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="29cn20qSmHuO00025QrE$V" Name="Pset_CondenserTypeCommon" Description="Condenser type common attributes." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCondenser">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_002JG0qWWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RefrigerantClass_0sT8u0qSiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ExternalSurfaceArea_2myTs0qSmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InternalSurfaceArea_2svxw0qSmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InternalRefrigerantVolume_2yHGa0qSmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InternalWaterVolume_31ebE0qSmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalHeatTransferArea_36PmU0qSmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalHeatTransferCoefficient_3Bn580qSmHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3H8Po0qSmHuO00025QrE$V" Name="Pset_Condition" Description="Determines the state or condition of an element at a particular point in time." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcElement,IfcSystem,IfcAsset">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="AssessmentDate_3N5ts0qSmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AssessmentCondition_3Rt360qSmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AssessmentDescription_3XENm0qSmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AssessmentType_3NSPfml8jBXg1KRcsojDrC" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AssessmentMethod_0jlpIbRpH4Hhz2PKb2XqoO" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LastAssessmentReport_1gG02PahnF2fsfAbELSVmv" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NextAssessmentDate_28osmmdGL2buGNDbDCM1B0" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AssessmentFrequency_3Y5J0kLVfDHfMH8$QTwre7" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3czcPErGH0YhnTpd4hPjFw" Name="Pset_ConstructionAdministration" Description="Properties for Construction Administration. Often used for facility and asset management." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcElement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ProcurementMethod_0HZB4plKf1oOsbtTq1O1Zs" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SpecificationSectionNumber_0$GZsDpVX0HeG5RURnigAw" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SubmittalIdentifer_155y_nDqr1ZxKrk6Ogjpca" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2Xxv48VWv4pASLA0W_pxEB" Name="Pset_ConstructionOccurence" Description="Property set for construction occurrence." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcElement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="InstallationDate_2k4h6AVrL8EBlzWRArJDjn" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ModelNumber_1jeF6zR3zCmAdTfELc98hB" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TagNumber_3eCIF8g3jEwAYZHzzhJlS$" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AssetIdentifier_3_jQ0YjzL52QWb$SZ4jXPk" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3eO8e0qSmHuO00025QrE$V" Name="Pset_ConstructionResource" Description="Properties for tracking resource usage over time." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcConstructionResource">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ScheduleWorkProgression_3kLci0qSmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ActualWorkTime_3nKLk0qSmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RemainingWorkProgression_3pixM0qSmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ScheduleCost_3shgO0qSmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ActualCost_3v4G00qSmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RemainingCost_3xSre0qSmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ScheduleCompletion_3_Rag0qSmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ActualCompletion_00qAI0qSqHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="04$C80qSqHuO00025QrE$V" Name="Pset_ControllerPHistory" Description="Properties for history of controller values. HISTORY: Added in IFC4." TemplateType="pset_performancedriven" ApplicableEntity="IfcController">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ValueHistory_09mNO0qSqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Quality_0Cl6Q0qSqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_0F7i20qSqHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0JIju0qSqHuO00025QrE$V" Name="Pset_ControllerTypeCommon" Description="Controller type common attributes." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcController">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_0SEw_0qSqHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0fyJK0qSqHuO00025QrE$V" Name="Pset_ControllerTypeFloating" Description="Properties for signal handling for an analog controller taking disparate valued multiple inputs and creating a single valued output. HISTORY: IFC4 adapted from Pset_ControllerTypeCommon and applicable predefined type made specific to FLOATING; ACCUMULATOR and PULSECONVERTER types added; additional properties added to replace Pset_AnalogInput and Pset_AnalogOutput." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcController/FLOATING">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ControlType_0kjUa0qSqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Labels_1MfKo0qSqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Range_1U$OU0qSqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Value_1ZmZk0qSqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SignalOffset_1fk1o0qSqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SignalFactor_1jv3e0qSqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SignalTime_1ogEu0qSqHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1u1ZY0qSqHuO00025QrE$V" Name="Pset_ControllerTypeMultiPosition" Description="Properties for discrete inputs, outputs, and values within a programmable logic controller. HISTORY: New in IFC4, replaces Pset_MultiStateInput and Pset_MultiStateOutput." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcController/MULTIPOSITION">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ControlType_1_bB00qSqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Labels_29vzk0qSqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IntegerRange_2H3kc0qSqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Value_2Lqvs0qSqHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2S_gk0qSqHuO00025QrE$V" Name="Pset_ControllerTypeProgrammable" Description="Properties for Discrete Digital Control (DDC) or programmable logic controllers. HISTORY: Added in IFC4." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcController/PROGRAMMABLE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ControlType_2X9ia0qSqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FirmwareVersion_2hICU0qSqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SoftwareVersion_2mfX80qSqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Application_1QbS56uHrAi9fxNRgZLeWS" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2tD8c0qSqHuO00025QrE$V" Name="Pset_ControllerTypeProportional" Description="Properties for signal handling for an proportional controller taking setpoint and feedback inputs and creating a single valued output. HISTORY: In IFC4, SignalFactor1, SignalFactor2 and SignalFactor3 changed to ProportionalConstant, IntegralConstant and DerivativeConstant.  SignalTime1 and SignalTime2 changed to SignalTimeIncrease and SignalTimeDecrease." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcController/PROPORTIONAL">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ControlType_2zAcg0qSqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Labels_1MfKo0qSqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Range_1U$OU0qSqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Value_3QNpa0qSqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ProportionalConstant_3XXaS0qSqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IntegralConstant_3cuv60qSqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DerivativeConstant_3hg4M0qSqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SignalTimeIncrease_3oDhq0qSqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SignalTimeDecrease_3tb0U0qSqHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3zYUY0qSqHuO00025QrE$V" Name="Pset_ControllerTypeTwoPosition" Description="Properties for signal handling for an analog controller taking disparate valued multiple inputs and creating a single valued binary output. HISTORY: In IFC4, extended properties to replace Pset_BinaryInput and Pset_BinaryOutput." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcController/TWOPOSITION">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ControlType_02vpC0qSuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Labels_0W7060qSuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Polarity_0dswO0qSuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Value_0jEF20qSuHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0qN$w0qSuHuO00025QrE$V" Name="Pset_CooledBeamPHistory" Description="Common performance history attributes for a cooled beam." TemplateType="pset_performancedriven" ApplicableEntity="IfcCooledBeam">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="TotalCoolingCapacity_0vlKa0qSuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TotalHeatingCapacity_0yk3c0qSuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BeamCoolingCapacity_10Iy20qSuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BeamHeatingCapacity_13Hh40qSuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoolingWaterFlowRate_16GQ60qSuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HeatingWaterFlowRate_19F980qSuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CorrectionFactorForCooling_1Cq1a0qSuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CorrectionFactorForHeating_1GOw00qSuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WaterPressureDropCurves_1JzoS0qSuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SupplyWaterTemperatureCooling_1NYgu0qSuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReturnWaterTemperatureCooling_1PxGW0qSuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SupplyWaterTemperatureHeating_1Sv$Y0qSuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReturnWaterTemperatureHeating_1WUt_0qSuHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1bG3E0qSuHuO00025QrE$V" Name="Pset_CooledBeamPHistoryActive" Description="Performance history attributes for an active cooled beam." TemplateType="pset_performancedriven" ApplicableEntity="IfcCooledBeam/ACTIVE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="AirFlowRate_1iPq60qSuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Throw_1l_iY0qSuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AirPressureDropCurves_1ozRa0qSuHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1sYK00qSuHuO00025QrE$V" Name="Pset_CooledBeamTypeActive" Description="Active (ventilated) cooled beam common attributes." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCooledBeam/ACTIVE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="AirFlowConfiguration_1yVo40qSuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AirFlowRateRange_2ApJq0qSuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SupplyAirConnectionType_2HMxI0qSuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConnectionSize_2WGcS0qSuHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2cE4W0qSuHuO00025QrE$V" Name="Pset_CooledBeamTypeCommon" Description="Cooled beam common attributes.
SoundLevel and SoundAttenuation attributes deleted in IFC2x2 Pset Addendum: Use IfcSoundProperties instead." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCooledBeam">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_2mMaQ0qSuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsFreeHanging_2$sO_0qSuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PipeConnection_0bnXS0qSyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WaterFlowControlSystemType_35Dje0qSuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WaterPressureRange_3LJhc0qSuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalCoolingCapacity_3RtJ40qSuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalSurroundingTemperatureCooling_3Xqn80qSuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalSurroundingHumidityCooling_3cbyO0qSuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalSupplyWaterTemperatureCooling_3hN7e0qSuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalReturnWaterTemperatureCooling_3mkSI0qSuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalWaterFlowCooling_3s5my0qSuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalHeatingCapacity_3y3F00qSuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalSurroundingTemperatureHeating_01QZg0qSyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalSupplyWaterTemperatureHeating_06Bkw0qSyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalReturnWaterTemperatureHeating_0AywA0qSyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalWaterFlowHeating_0GKEq0qSyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IntegratedLightingType_0LhZU0qSyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FinishColour_0qhCc0qSyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoilLength_0w2XG0qSyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoilWidth_0_piW0qSyHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="14nAa0qSyHuO00025QrE$V" Name="Pset_CoolingTowerPHistory" Description="Cooling tower performance history attributes." TemplateType="pset_performancedriven" ApplicableEntity="IfcCoolingTower">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Capacity_1Akee0qSyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HeatTransferCoefficient_1DjNg0qSyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SumpHeaterPower_1Gi6i0qSyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UACurve_1KG$80qSyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Performance_1Nrta0qSyHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1RQm00qSyHuO00025QrE$V" Name="Pset_CoolingTowerTypeCommon" Description="Cooling tower type common attributes.
WaterRequirement attribute unit type modified in IFC2x2 Pset Addendum." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCoolingTower">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_1clYk0qSyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalCapacity_1rfDu0qSyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CircuitType_1x0YY0qSyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FlowArrangement_29K4I0qSyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SprayType_2Lr9q0qSyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CapacityControl_2bK_O0qSyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ControlStrategy_35WwK0qSyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfCells_3Grj20qSyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BasinReserveVolume_3MD1i0qSyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LiftElevationDifference_3RaMM0qSyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WaterRequirement_3WLXc0qSyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OperationTemperatureRange_3b6is0qSyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AmbientDesignDryBulbTemperature_3ftu60qSyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AmbientDesignWetBulbTemperature_3lFCm0qSyHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0RRBEgbUbFx8qQrjK2xRI4" Name="Pset_CourseApplicationConditions" Description="Properties regarding the conditions when applying a course." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcCourse">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ApplicationTemperature_2GA6uBu4jFeRzE7Yu7b791" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WeatherConditions_0xXHu3ITj3DPV0alWk63er" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3IE0kQTsb1r9Cc4EPpArTj" Name="Pset_CourseCommon" Description="Common properties for courses." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCourse">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalLength_0NS18P1J51kRFniH3h5CIL" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalThickness_3cTq6sD71BVAf9l72L6lIy" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalWidth_2YZfyYRY1Aa9bsWGvZEaNq" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3roqE0qSyHuO00025QrE$V" Name="Pset_CoveringCeiling" Description="Properties common to the definition of all occurrence and type objects of covering with the predefined type set to CEILING." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCovering/CEILING">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Permeability_3_l1K0qSyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TileLength_046L_0qT0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TileWidth_09Tge0qT0HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0HDaw0qT0HuO00025QrE$V" Name="Pset_CoveringCommon" Description="Properties common to the definition of all occurrence and type objects of covering" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCovering">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_0Q9o00qT0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AcousticRating_0kQnq0qT0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FlammabilityRating_0qOFu0qT0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FragilityRating_0vlaY0qT0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Combustible_15gWg0qT0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SurfaceSpreadOfFlame_0$6vC0qT0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Finish_1MMe20qT0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsExternal_1Bd_k0qT0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ThermalTransmittance_1Xzda0qSaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FireRating_0Jj9g0qWWHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1SK660qT0HuO00025QrE$V" Name="Pset_CoveringFlooring" Description="Properties common to the definition of all occurrence and type objects of covering with the predefined type set to FLOORING." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCovering/FLOORING">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasNonSkidSurface_1Ytja0qT0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasAntiStaticSurface_1eF2E0qT0HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="17POm$Kwd5xBxEXf81lSPO" Name="Pset_CoveringTypeMembrane" Description="Property set for overing Type Membrane." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCovering/MEMBRANE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalInstallationDepth_2yE9Yxgxv0KRzH8vY2fcco" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalTransverseInclination_3Cd$wHaE95zeG4Dy9Ad2WJ" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2w3gSa$39jSNiLp2HrKYHd" Name="Pset_CurrentInstrumentTransformer" Description="Instrument transformers are high accuracy class electrical devices used to isolate or transform voltage or current levels. The main function of instrument transformers is to operate instruments or metering from high voltage or high current circuits, safely isolating secondary control circuitry from the high voltages or currents. Combination instrument transformers are metering current." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcFlowInstrument/AMMETER,IfcFlowInstrument/COMBINED">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="AccuracyClass_32YEer4tP9EB633g5FK49p" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AccuracyGrade_3y6bNc8F56Hexr9v$dk$2L" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RatedVoltage_2YuL_rvIv9uxXdCK0Vu7_6" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalCurrent_0sDhk0qUWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalPower_2pu16hiH1CqQv04BNgxAph" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfPhases_1BIplyxBLFfuml0KvHZ1y2" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PrimaryFrequency_1tZv40qX4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PrimaryCurrent_1gSg80qX4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SecondaryFrequency_1_7WY0qX4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SecondaryCurrent_1n0Hc0qX4HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1kCWI0qT0HuO00025QrE$V" Name="Pset_CurtainWallCommon" Description="Properties common to the definition of all occurrences of IfcCurtainWall." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCurtainWall">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_1xvue0qT0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AcousticRating_0kQnq0qT0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FireRating_0Jj9g0qWWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Combustible_2MkVw0qT0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SurfaceSpreadOfFlame_0$6vC0qT0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ThermalTransmittance_1Xzda0qSaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsExternal_2cEKU0qT0HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2iBoY0qT0HuO00025QrE$V" Name="Pset_DamperOccurrence" Description="Damper occurrence attributes attached to an instance of IfcDamper" TemplateType="pset_occurrencedriven" ApplicableEntity="IfcDamper">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SizingMethod_2o9Gc0qT0HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2_4Ck0qT0HuO00025QrE$V" Name="Pset_DamperPHistory" Description="Damper performance history attributes." TemplateType="pset_performancedriven" ApplicableEntity="IfcDamper">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="AirFlowRate_33RXO0qT0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Leakage_370Pq0qT0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PressureDrop_39$8s0qT0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BladePositionAngle_3CNkU0qT0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DamperPosition_3Fycw0qT0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PressureLossCoefficient_3IxLy0qT0HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3N6No0qT0HuO00025QrE$V" Name="Pset_DamperTypeCommon" Description="Damper type common attributes." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDamper">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_3Xr160qT0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Operation_3m8Ys0qT0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Orientation_3yfeO0qT0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BladeThickness_0DxvA0qT4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BladeAction_0Mu6G0qT4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BladeShape_0bBe00qT4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BladeEdge_0nijY0qT4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberofBlades_0z1WG0qT4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FaceArea_12Oqw0qT4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumAirFlowRate_17m9a0qT4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TemperatureRange_1CXKq0qT4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumWorkingPressure_1Jh5i0qT4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TemperatureRating_1P2QM0qT4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalAirFlowRate_1UPl00qT4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OpenPressureDrop_1ZAwG0qT4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LeakageFullyClosed_1dy5W0qT4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LossCoefficentCurve_1ijGm0qT4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LeakageCurve_1r3KS0qT4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RegeneratedSoundCurve_1zPO80qT4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FrameType_259IQ0qT4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FrameDepth_2B6mU0qT4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FrameThickness_2JSqA0qT4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CloseOffRating_2Oq8q0qT4HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2UBTU0qT4HuO00025QrE$V" Name="Pset_DamperTypeControlDamper" Description="Control damper type attributes.
Pset renamed from Pset_DamperTypeControl to Pset_DamperTypeControlDamper in IFC2x2 Pset Addendum." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDamper/CONTROLDAMPER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="TorqueRange_2ZYo80qT4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ControlDamperOperation_2g6Pc0qT4HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2tpny0qT4HuO00025QrE$V" Name="Pset_DamperTypeFireDamper" Description="Fire damper type attributes.
Pset renamed from Pset_DamperTypeFire to Pset_DamperTypeFireDamper in IFC2x2 Pset Addendum." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDamper/FIREDAMPER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ActuationType_2yazC0qT4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ClosureRatingEnum_3962k0qT4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FireResistanceRating_3MDHg0qT4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FusibleLinkTemperature_3SAlk0qT4HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3YkNC0qT4HuO00025QrE$V" Name="Pset_DamperTypeFireSmokeDamper" Description="Combination Fire and Smoke damper type attributes.
New Pset in IFC2x2 Pset Addendum." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDamper/FIRESMOKEDAMPER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="DamperControlType_3dVYS0qT4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ActuationType_3jT0W0qT4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ClosureRatingEnum_3waFS0qT4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FireResistanceRating_075K_0qT8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FusibleLinkTemperature_0BsWE0qT8HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0IQ7i0qT8HuO00025QrE$V" Name="Pset_DamperTypeSmokeDamper" Description="Smoke damper type attributes.
Pset renamed from Pset_DamperTypeSmoke to Pset_DamperTypeSmokeDamper in IFC2x2 Pset Addendum." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDamper/SMOKEDAMPER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ControlType_0NBIy0qT8HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2IL3Kqvh4_WmQQZWIVqQYa" Name="Pset_DataTransmissionUnit" Description="Properties common to a data transmission unit. This property set is applied to a type or occurrence of _IfcCommunicationsAppliance_ with predefined type MODEM." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCommunicationsAppliance/MODEM">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="WorkingState_2qD57tYLb86QIkv8vmjv3f" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SerialInterfaceType_0IV69mrp50xeArXDuk$7Y6" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DataTransmissionUnitUsage_33Z4KU$Gv1RhPZvo_1CDMa" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0TkwQ0qT8HuO00025QrE$V" Name="Pset_DiscreteAccessoryColumnShoe" Description="Shape properties common to column shoes." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDiscreteAccessory/SHOE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ColumnShoeBasePlateThickness_0c4_60qT8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ColumnShoeBasePlateWidth_0i2SA0qT8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ColumnShoeBasePlateDepth_0mpdQ0qT8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ColumnShoeCasingHeight_0sAy40qT8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ColumnShoeCasingWidth_0wy7K0qT8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ColumnShoeCasingDepth_10JR_0qT8HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="16t3S0qT8HuO00025QrE$V" Name="Pset_DiscreteAccessoryCornerFixingPlate" Description="Properties specific to corner fixing plates." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDiscreteAccessory">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="CornerFixingPlateLength_1BeEi0qT8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CornerFixingPlateThickness_1G$ZM0qT8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CornerFixingPlateFlangeWidthInPlaneZ_1MMu00qT8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CornerFixingPlateFlangeWidthInPlaneX_1RkCg0qT8HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1Xhgk0qT8HuO00025QrE$V" Name="Pset_DiscreteAccessoryDiagonalTrussConnector" Description="Shape properties specific to connecting accessories in truss form with diagonal cross-bars." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDiscreteAccessory">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="DiagonalTrussHeight_1df8o0qT8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DiagonalTrussLength_1j0TS0qT8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DiagonalTrussCrossBarSpacing_1nnei0qT8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DiagonalTrussBaseBarDiameter_1t8zM0qT8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DiagonalTrussSecondaryBarDiameter_1yWI00qT8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DiagonalTrussCrossBarDiameter_21tcg0qT8HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="27r4k0qT8HuO00025QrE$V" Name="Pset_DiscreteAccessoryEdgeFixingPlate" Description="Properties specific to edge fixing plates." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDiscreteAccessory">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="EdgeFixingPlateLength_2DCPO0qT8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EdgeFixingPlateThickness_2IZk20qT8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EdgeFixingPlateFlangeWidthInPlaneZ_2Nx2i0qT8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EdgeFixingPlateFlangeWidthInPlaneX_2TINM0qT8HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2Zr_q0qT8HuO00025QrE$V" Name="Pset_DiscreteAccessoryFixingSocket" Description="Properties common to fixing sockets." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDiscreteAccessory">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="FixingSocketTypeReference_2fDJU0qT8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FixingSocketHeight_2hbv60qT8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FixingSocketThreadDiameter_2mzDm0qT8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FixingSocketThreadLength_2sKYQ0qT8HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2yu9u0qT8HuO00025QrE$V" Name="Pset_DiscreteAccessoryLadderTrussConnector" Description="Shape properties specific to connecting accessories in truss form with straight cross-bars in ladder shape." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDiscreteAccessory">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="LadderTrussHeight_32FUY0qT8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LadderTrussLength_370fo0qT8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LadderTrussCrossBarSpacing_3DaHG0qT8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LadderTrussBaseBarDiameter_3ILSW0qT8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LadderTrussSecondaryBarDiameter_3OIwa0qT8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LadderTrussCrossBarDiameter_3TgFE0qT8HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3ZdjI0qT8HuO00025QrE$V" Name="Pset_DiscreteAccessoryStandardFixingPlate" Description="Properties specific to standard fixing plates." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDiscreteAccessory">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="StandardFixingPlateWidth_3e$1y0qT8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="StandardFixingPlateDepth_3kyW00qT8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="StandardFixingPlateThickness_3qJqg0qT8HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2oQKs0c9_FRcUKQWnvCQkF" Name="Pset_DiscreteAccessoryTypeBracket" Description="Properties of a bracket. The property set can be used by the predefined type BRACKET of IfcDiscreteAccessory." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDiscreteAccessory/BRACKET">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsInsulated_0Eq$IgBvz97uWvPsoTH$G9" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0tOwhMzFZVaVKJuF60ysyg" Name="Pset_DiscreteAccessoryTypeCableArranger" Description="Properties used for a cable arranger. The property set can be used by the predefined type CABLEARRANGER of IfcDiscreteAccessory." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDiscreteAccessory/CABLEARRANGER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="CableArrangerPosition_1bt9RJJNv7CeH$s$fdSlY0" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0gvQ9DkosW_LgM0Ggr1BiM" Name="Pset_DiscreteAccessoryTypeInsulator" Description="Properties of an insulator. The property set can be used by the predefined type INSULATOR of IfcDiscreteAccessory." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDiscreteAccessory/INSULATOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="RatedCurrent_1uJPqXHDH0jRCEAj47O9L8" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RatedVoltage_0_oie0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumInsulatedVoltage_1Rmq9PJnfEKuHYQTF1jjZg" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BreakdownVoltageTolerance_36oHQCC0b0jubTadGmGjOS" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InsulationMethod_1_Ub8uyHX2dgCLYmh2_Ttw" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OperationalTemperatureRange_2hvjQhIJj5c9PrmgrOQl1i" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CreepageDistance_2gR0dwi6P8TOicDILZQqwo" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InstallationMethod_1y3E9FdGDDcuFQAiNae6DC" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LightningPeakVoltage_1UDgFBVIXA9OYX1_nAvy5o" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BendingStrength_1mJcyU5FjEvPlHNmb60SjF" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RMSWithstandVoltage_29RnvrWq5DXAWWDKKhvsNo" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Voltage_27j$QobBL4UhVjgWuhQGvz" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0AUW2B8RF8zZ9grPyGUWHc" Name="Pset_DiscreteAccessoryTypeLock" Description="Properties of locking equipment. The property set can be used by the predefined type LOCK of IfcDiscreteAccessory." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDiscreteAccessory/LOCK">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="InstallationPlan_2beGsManD6zPMmBIW4LY_Q" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RequiredClosureSpacing_0gtHi_RV90UARAfwx4UFx3" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3rALbW$vhblsgfpwGBPvZP" Name="Pset_DiscreteAccessoryTypeRailBrace" Description="Properties of a rail brace. The property set can be used by the predefined type RAILBRACE of IfcDiscreteAccessory." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDiscreteAccessory/RAILBRACE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsTemporary_1kVVwEVWv2m8yxnkRxkynp" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3Huy7s8vwxOUufGAsisakT" Name="Pset_DiscreteAccessoryTypeRailLubrication" Description="Properties of rail lubrication equipment. The property set can be used by the predefined type RAIL_LUBRICATION of IfcDiscreteAccessory." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDiscreteAccessory/RAIL_LUBRICATION">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="PositionInTrack_2$JKUv68rC$QfoodxwEHNq" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumNoiseEmissions_02ksEi$yvANQhP$HONlrqo" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LubricationSystemType_2aGJLDX7bAguqlV$JHtrbv" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LubricationPowerSupplyType_27I6bQ4Fj9NA8AgikwDk3z" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="27VvSW5MoyCghKPQOuHFPe" Name="Pset_DiscreteAccessoryTypeRailPad" Description="Properties of rail pads. The property set can be used by the predefined type RAILPAD of IfcDiscreteAccessory." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDiscreteAccessory/RAILPAD">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="RailPadStiffness_26aYV31ZvC_QTcssV9r4Tb" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2rfekAligL3H6n0b8iuAJB" Name="Pset_DiscreteAccessoryTypeSlidingChair" Description="Properties of a sliding chair. The property set can be used by the predefined type SLIDINGCHAIR of IfcDiscreteAccessory." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDiscreteAccessory/SLIDINGCHAIR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsSelfLubricated_1$jckKQnr1M8meRe1yLTIe" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="06eNR696HYdydEAHrXKVQB" Name="Pset_DiscreteAccessoryTypeSoundAbsorption" Description="Properties of sound absorption equipment used in railway. The property set can be used by the predefined type SOUNDABSORPTION of IfcDiscreteAccessory." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDiscreteAccessory/SOUNDABSORPTION">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SoundAbsorptionLimit_3Dyb6v_Lb0uePKj$y26Fb4" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1fsz4GT$bSdTSAE2ExsoZs" Name="Pset_DiscreteAccessoryTypeTensioningEquipment" Description="Properties of tensioning equipment used in railway. The property set can be used by the predefined type TENSIONINGEQUIPMENT of IfcDiscreteAccessory." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDiscreteAccessory/TENSIONINGEQUIPMENT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReferenceEnvironmentTemperature_2vgOshA4D0$ems5HSBwemr" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AssemblyInstruction_3W5i6nbkP9NBt_M6PTB5jW" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasBreakLineLock_1iKdHvSGX0pxudZvZ2KLk8" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TensileStrength_1ZuJdL4cPBOuLWEzKCV5K4" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RatioOfWireTension_3jOIIDu3fDzgwbbcxO3kVC" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TransmissionEfficiency_1Ye$qvI7T6Pg_7_vkyG8B4" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="12NWTVLbf8ERZFInCGuFfL" Name="Pset_DiscreteAccessoryTypeWaterBarrier" Description="Properties for discrete accessories of type water barrier." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDiscreteAccessory/WATER_BARRIER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SealType_31DmCfobH23ezb7so63KdY" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3wtS80qT8HuO00025QrE$V" Name="Pset_DiscreteAccessoryWireLoop" Description="Shape properties common to wire loop joint connectors." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDiscreteAccessory">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="WireLoopBasePlateThickness_00Emo0qTCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WireLoopBasePlateWidth_05c5S0qTCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WireLoopBasePlateLength_0EYIY0qTCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WireDiameter_0MICq0qTCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WireEmbeddingLength_0bBt_0qTCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WireLoopLength_0ovGK0qTCHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3J2$L3pXT2Xu_8tEfumC0$" Name="Pset_DistributionBoardOccurrence" Description="Properties that may be applied to electric distribution board occurrences." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcElectricDistributionBoard">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsMain_38kVnOpG9ExQCWZ$aM22lh" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsSkilledOperator_126zTH3Fb7s9WfKr4C5g0Q" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3WNXM0qTyHuO00025QrE$V" Name="Pset_DistributionBoardTypeCommon" Description="Properties that may be applied to electric distribution boards." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcElectricDistributionBoard">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_3iucu0qTyHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2JjXCvKH61OIRd3VPVX$vj" Name="Pset_DistributionBoardTypeDispatchingBoard" Description="Properties for _IfcDistributionBoard_ with PredefinedType DISPATCHINGBOARD." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDistributionBoard/DISPATCHINGBOARD">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfInterfaces_3D0wHuI4P3guCzHoS3Y4Zf" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DispatchingBoardType_3Uy7R9ZWXByPXF2xHimATv" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0rpq7Z5ddWqIdRiwgzq4rY" Name="Pset_DistributionBoardTypeDistributionFrame" Description="Properties for _IfcDistributionBoard_ with PredefinedType DISTRIBUTIONFRAME." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDistributionBoard/DISTRIBUTIONFRAME">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="PortCapacity_2wGIZukqb5y8_rmxPBWB8h" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="11oxU0qTCHuO00025QrE$V" Name="Pset_DistributionChamberElementCommon" Description="Common properties of all occurrences of IfcDistributionChamberElement." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDistributionChamberElement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_02_Yc0qVGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_1UP__0qTCHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1jJg80qTCHuO00025QrE$V" Name="Pset_DistributionChamberElementTypeFormedDuct" Description="Space formed in the ground for the passage of pipes, cables, ducts." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDistributionChamberElement/FORMEDDUCT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ClearWidth_1pH8C0qTCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ClearDepth_1ueSs0qTCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WallThickness_1_bww0qTCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BaseThickness_23N6A0qTCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AccessCoverLoadRating_28kQq0qTCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CableDuctOccupancyRatio_3H1ZJK$c58WQOmBVrQdG$S" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2Ehuu0qTCHuO00025QrE$V" Name="Pset_DistributionChamberElementTypeInspectionChamber" Description="Chamber constructed on a drain, sewer or pipeline and with a removable cover, that permits visible inspection." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDistributionChamberElement/INSPECTIONCHAMBER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ChamberLengthOrRadius_2JT480qTCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ChamberWidth_2OqOo0qTCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InspectionChamberInvertLevel_2UBjS0qTCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SoffitLevel_2YMlI0qTCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WallMaterial_2eKDM0qTCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WallThickness_1_bww0qTCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BaseMaterial_2m47e0qTCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BaseThickness_2p2sg0qTCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WithBackdrop_2uQBK0qTCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AccessCoverMaterial_0ZieS0qTGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AccessLengthOrRadius_30mF00qTCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AccessWidth_367Zg0qTCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AccessCoverLoadRating_3KR5Q0qTCHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3Q_iu0qTCHuO00025QrE$V" Name="Pset_DistributionChamberElementTypeInspectionPit" Description="Recess or chamber formed to permit access for inspection of substructure and services (definition modified from BS6100 221 4128)." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDistributionChamberElement/INSPECTIONPIT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Length_3WM1Y0qTCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Width_3cvf00qTCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Depth_3iGzg0qTCHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3oqb80qTCHuO00025QrE$V" Name="Pset_DistributionChamberElementTypeManhole" Description="Chamber constructed on a drain, sewer or pipeline and with a removable cover, that permits the entry of a person." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDistributionChamberElement/MANHOLE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="InvertLevel_3tbmO0qTCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SoffitLevel_3yMxe0qTCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WallMaterial_0186u0qTGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WallThickness_1_bww0qTCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BaseMaterial_0A4J_0qTGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BaseThickness_23N6A0qTCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsShallow_0J0X40qTGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasSteps_0ONrk0qTGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WithBackdrop_0TlAO0qTGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AccessLengthOrRadius_0chNU0qTGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AccessWidth_0ierY0qTGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AccessCoverLoadRating_0ocJc0qTGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsAccessibleOnFoot_31J5jTh9z80B8lERH0gDCc" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsLocked_2RDCAlPobEcu$7w2dT8CcG" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfCableEntries_1GIp0NSLHCAfwnDUczWxZc" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfManholeCovers_3pgyG1ge167gvAIBWW6ZBC" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TypeOfShaft_3CsdA17mP3S96HzWjfIsoL" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AccessCoverMaterial_0ZieS0qTGHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0uZng0qTGHuO00025QrE$V" Name="Pset_DistributionChamberElementTypeMeterChamber" Description="Chamber that houses a meter(s) (definition modified from BS6100 250 6224)." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDistributionChamberElement/METERCHAMBER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ChamberLengthOrRadius_0zKyw0qTGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ChamberWidth_12iHa0qTGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WallMaterial_18fle0qTGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WallThickness_1_bww0qTCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BaseMaterial_1IC680qTGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BaseThickness_23N6A0qTCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AccessCoverMaterial_0ZieS0qTGHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1VJL40qTGHuO00025QrE$V" Name="Pset_DistributionChamberElementTypeSump" Description="Recess or small chamber into which liquid is drained to facilitate its removal." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDistributionChamberElement/SUMP">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Length_3WM1Y0qTCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Width_3cvf00qTCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SumpInvertLevel_1mbbs0qTGHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1tlMk0qTGHuO00025QrE$V" Name="Pset_DistributionChamberElementTypeTrench" Description="Excavation, the length of which greatly exceeds the width." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDistributionChamberElement/TRENCH">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Width_3cvf00qTCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Depth_3iGzg0qTCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InvertLevel_29dmw0qTGHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2HNhC0qTGHuO00025QrE$V" Name="Pset_DistributionChamberElementTypeValveChamber" Description="Chamber that houses a valve(s)." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDistributionChamberElement/VALVECHAMBER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ChamberLengthOrRadius_2M8sS0qTGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ChamberWidth_2S6KW0qTGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WallMaterial_2Y3oa0qTGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WallThickness_1_bww0qTCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BaseMaterial_2iCIU0qTGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BaseThickness_23N6A0qTCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AccessCoverMaterial_0ZieS0qTGHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2x5ze0qTGHuO00025QrE$V" Name="Pset_DistributionPortCommon" Description="Common attributes attached to an instance of IfcDistributionPort." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcDistributionPort">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="PortNumber_30TII0qTGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ColourCode_37d3A0qTGHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2l0ND8kiD9BuPhGyw1F3Nu" Name="Pset_DistributionPortPHistoryCable" Description="Log of electrical activity attached to an instance of IfcPerformanceHistory having an assigned IfcDistributionPort of type CABLE." TemplateType="pset_performancedriven" ApplicableEntity="IfcDistributionPort/CABLE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="CurrentHistory_2VhUjrajvA8eTamaxazsiB" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VoltageHistory_1lg7CDGrH2v9TIUzdU$h17" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RealPower_3xhiQ9aS5FZx39O_jb9Gyc" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReactivePower_107SSt09T8QPi7FlONxs5S" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ApparentPower_2lYNHW98j2TeNYYr2i$746" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PowerFactorHistory_1Jv3lEllLAG9RzY6AaK90z" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DataTransmitted_31sBJr1t94sOktsMuxcZA2" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DataReceived_3dAyrzXAv2nh7ZzfP57Hvk" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2TqYSrZIj33BZ8h3kBVuzo" Name="Pset_DistributionPortPHistoryDuct" Description="Fluid flow performance history attached to an instance of IfcPerformanceHistory assigned to IfcDistributionPort. This replaces the deprecated IfcFluidFlowProperties for performance values." TemplateType="pset_performancedriven" ApplicableEntity="IfcDistributionPort/DUCT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="TemperatureHistory_3Bw5L2Vz5DeAATs0TdVhIf" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WetBulbTemperatureHistory_30J$B7lK58sesE0tH79del" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VolumetricFlowRateHistory_1_ZeVmL9X3mAEUYAm$5rnk" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MassFlowRateHistory_2_Ce9CHon4wAjnpmQnq8Z9" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FlowConditionHistory_0vwzjJx0fC_vmMqxa_ItdJ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VelocityHistory_20kOv3DPrDmhnl7ZnOP9ZX" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PressureHistory_21I6029$T09OOx3TehMZSk" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3$wAqbzzTDLQZwcfCuifUo" Name="Pset_DistributionPortPHistoryPipe" Description="Log of substance usage attached to an instance of IfcPerformanceHistory having an assigned IfcDistributionPort of type PIPE." TemplateType="pset_performancedriven" ApplicableEntity="IfcDistributionPort/PIPE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Temperature_2sotI3fbrBrQnbKR204MCZ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Pressure_1rWyryNgTD49uhQjRGslfB" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Flowrate_1wFslkM110DwcNqSBBrefD" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0K3BsSu295WAJIS$O2CC8E" Name="Pset_DistributionPortTypeCable" Description="Cable port occurrence attributes attached to an instance of IfcDistributionPort." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcDistributionPort/CABLE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ElectricalConnectionType_0RKQL3FvDFfwK378TxjBGf" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConnectionSubtype_1A5cORvpX3_vdhIOgP0LY0" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConnectionGender_1QcnE_aj55XODZJWLi4uym" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConductorFunction_03sO5GIyzFT8intkW6NLbP" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CurrentContent3rdHarmonic_3g_0_IvjzCAQ60XkYRwY3f" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Current_1I1maXboTEcP5x$ShYx_g0" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Voltage_27j$QobBL4UhVjgWuhQGvz" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Power_13VYb5tj10cOr5hZsTbt3R" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Protocols_0LajgwBXH9KgSPIIIBgr3C" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasConnector_2Bkoo$GzT9FxN8$7msTZGo" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsWelded_1ZxOPXMGT17eoWdZAFb$Ls" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3ZeFVthabE2BgZHqqO5lhz" Name="Pset_DistributionPortTypeDuct" Description="Duct port occurrence attributes attached to an instance of IfcDistributionPort." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcDistributionPort/DUCT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConnectionType_3IiZcc7R5CAhGZuzSrfjuV" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConnectionSubtype_0LsHRT7ND0l8585NRu7Ie8" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalWidth_2YZfyYRY1Aa9bsWGvZEaNq" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalHeight_2GgGGOa7f1W9fIUx7l1f05" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalThickness_3cTq6sD71BVAf9l72L6lIy" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DryBulbTemperature_0EADBlvGD6CPPayNvIwz4O" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WetBulbTemperature_16vijFFij05hFPKkmcWspc" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VolumetricFlowRate_1Zd01dwqHEsBdHToHy7np2" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Velocity_0cKuKOg$P7Mw5MBESnrvTU" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Pressure_3CIho6yXrEuwXjE1K1d5gp" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3eMMVMiSDCF9C30UzZZqUF" Name="Pset_DistributionPortTypePipe" Description="Pipe port occurrence attributes attached to an instance of IfcDistributionPort." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcDistributionPort/PIPE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConnectionType_3uGgYTZiL73BYwV_npECRZ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConnectionSubtype_3V7JbtIxHAZPR8CmMAy3dW" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalDiameter_2idNc0CVn4uOAABCTgvTXi" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InnerDiameter_3yqzmY$VrEe8Jo0Bw35LgZ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OuterDiameter_1D65QTyIPFEwphBQILyT$Q" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Temperature_2X4Q_Kl0H0EBR1WDZY8wN$" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VolumetricFlowRate_2q9IxoM5X6NOGEDJdRVkrU" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MassFlowRate_2ZstQG09z2gOYfzMWxAUkF" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FlowCondition_2WdoXb4UbD3vEHayBW5LaX" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Velocity_1$hsml_zP31BE8MHPk06nA" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Pressure_3CIho6yXrEuwXjE1K1d5gp" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1kpvY0qTeHuO00025QrE$V" Name="Pset_DistributionSystemCommon" Description="Distribution system occurrence attributes attached to an instance of IfcDistributionSystem." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcDistributionSystem">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_1qBEC0qTeHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1wkrg0qTeHuO00025QrE$V" Name="Pset_DistributionSystemTypeElectrical" Description="Properties of electrical circuits." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcDistributionSystem/ELECTRICAL">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ElectricalSystemType_206AK0qTeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ElectricalSystemCategory_2GoHi0qTeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Diversity_2V5pS0qTeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfLiveConductors_04YqC0HsT3XhYwMsYCWtlQ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumAllowedVoltageDrop_2fEJM0qTeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetImpedance_2j$Uc0qTeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RatedVoltageRange_2Yd6MqG2nFieRrEL44q9kc" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1Ww8mkAaIrq3I087nk0neT" Name="Pset_DistributionSystemTypeOverheadContactlineSystem" Description="Properties of an overhead contact line system. The property set is associated with the predefined type OVERHEAD_CONTACT_LINE_SYSTEM of _IfcDistributionSystem_." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcDistributionSystem/OVERHEAD_CONTACTLINE_SYSTEM">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SpanNominalLength_0oTEbvO096Gv87GKVYXQSy" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ContactWireStagger_1dWD_52DDFheUkLfvK_Wga" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ContactWireNominalDrop_0PafkcBBDBPAuLjLmX5W1c" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PressureRange_0QnhC0qTuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ContactWireNominalHeight_1WIgSUjRrA2vcLynsmAyg4" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ContactWireUplift_2SxilVeerCTud05s6E45Pj" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ElectricalClearance_3Ccusqm3PAbetmCrKaebrB" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfOverlappingSpans_11jY1X9aT9DQa8E5Lr$tNh" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PantographType_1qXzLtDkHAO9qk9H6cFVer" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TensionLength_1d74zz$bb9fhB4vQYs3GO$" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OCSType_2VGXY51WP7ahpqQLujiu8W" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2qZ640qTeHuO00025QrE$V" Name="Pset_DistributionSystemTypeVentilation" Description="This property set is used to define the general characteristics of the duct design parameters within a system.
HISTORY: New property set in IFC Release 2.0.  Renamed from Pset_DuctDesignCriteria in IFC4." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcDistributionSystem/VENTILATION">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="DesignName_2vKHK0qTeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DuctSizingMethod_2$tuo0qTeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PressureClass_3EBQY0qTeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LeakageClass_3JYlC0qTeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FrictionLoss_3OJwS0qTeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ScrapFactor_3ThF60qTeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DuctSealant_3YSQM0qTeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumVelocity_3cdSC0qTeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AspectRatio_3kzVu0qTeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MinimumHeight_3uVsO0qTeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MinimumWidth_02eMI0qTiHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0EZIQ0qTiHuO00025QrE$V" Name="Pset_DoorCommon" Description="Properties common to the definition of all occurrences of IfcDoor." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDoor">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_0owGC0qTiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FireRating_0Jj9g0qWWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AcousticRating_2LGWE0qTiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SecurityRating_2qG9M0qTiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DurabilityRating_3DuTq0qTiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HygrothermalRating_3iHzY0qTiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WaterTightnessRating_1GCF129DbCTAkdKob1SB8d" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MechanicalLoadRating_3QctZVg8j5E8XzJ5bw45dT" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WindLoadRating_2Ru8al_J91DRslpPXuAcJ$" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Infiltration_0ZjeK0qTmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsExternal_0AhTG0qTmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ThermalTransmittance_12jHS0qTmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GlazingAreaFraction_1TXuk0qTmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HandicapAccessible_1sa3o0qTmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FireExit_2FcEs0qTmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasDrive_2gQs80qTmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SelfClosing_2_hry0qTmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SmokeStop_3Enpw0qTmHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3_FTrO47D19eIJ5NzUGqoo" Name="Pset_DoorLiningProperties" Description="Properties of the door lining.

&gt; HISTORY&amp;nbsp; New property set in IFC4.3.2.0 to replace the entity IfcDoorLiningProperties" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDoor,IfcMember">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="LiningDepth_1G_SQtW4j5pxKrrTsULYJ5" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LiningThickness_2BYAcFEujALBCPBrRERjlx" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ThresholdDepth_0YTLDOcv95LhDSgYmDJB$w" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ThresholdThickness_3NZoBtv0jFB84syr_irEvy" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TransomThickness_0OtuFGWo94LwLOfFn_ymY$" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TransomOffset_0jDD0MGir5iAGDaRD8y3Ve" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LiningOffset_1cgphqjyn8jguBS5oJGpbV" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ThresholdOffset_2vEMEd$u99aB$arE6M66kV" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CasingThickness_04ZR14r_9C_vLSphKOkvKo" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CasingDepth_0gmV1hVbn8NwnhNgylps28" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LiningToPanelOffsetX_0hdVnTz9j3fRec1g0eGhK2" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LiningToPanelOffsetY_1pT3EEArz94xz7MrzElsni" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3BXQ3cxi55B8OJisoGf$nN" Name="Pset_DoorPanelProperties" Description="Properties of the door panel.

&gt; HISTORY&amp;nbsp; New property set in IFC4.3.2.0 to replace the entity IfcDoorPanelProperties" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDoor,IfcPlate">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="PanelDepth_1fsUAU0FL6EgPG63h62fdV" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PanelOperation_1ay2hmlBz0tgvLaClvI6lf" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PanelWidth_0vNnM_UAj1FRUKankwRRer" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PanelPosition_2FriHyz6DAhOkwyiZ6nfWZ" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="358pSGOVIEjnXROB0yKig0" Name="Pset_DoorTypeTurnstile" Description="Properties common to turnstiles or automatic gates used to control the flow of people or vehicles. This property set is applied to IfcDoor instances of predefined type TURNSTILE." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDoor/TURNSTILE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsBidirectional_3PYJ6a4gXACx94JYuDo4no" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TurnstileType_3yE$cMPun2Du7wMts2JRaM" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NarrowChannelWidth_260oCTccX4deJp$Xc0XFb_" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WideChannelWidth_3SSA9HxpbBze$AzEvzUdRN" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3cdiA0qTmHuO00025QrE$V" Name="Pset_DoorWindowGlazingType" Description="Properties common to the definition of the glazing component of occurrences of IfcDoor and IfcWindow, used for thermal and lighting calculations." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDoor,IfcWindow">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GlassLayers_0DzO_0qTqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GlassThickness1_0QUUW0qTqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GlassThickness2_0dbjS0qTqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GlassThickness3_0oKMm0qTqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FillGas_0zf9U0qTqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GlassColour_18zyC0qTqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsTempered_1Hw9I0qTqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsLaminated_1Tr5Q0qTqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsCoated_1f9u80qTqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsWired_1o65E0qTqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VisibleLightReflectance_1wS8w0qTqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VisibleLightTransmittance_20Pc_0qTqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SolarAbsorption_24aeq0qTqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SolarReflectance_28lgg0qTqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SolarTransmittance_2CwiW0qTqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SolarHeatGainTransmittance_2Hhtm0qTqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShadingCoefficient_2Lsvc0qTqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ThermalTransmittanceSummer_2Q1xS0qTqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ThermalTransmittanceWinter_2UCzI0qTqHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3SoOy0qTqHuO00025QrE$V" Name="Pset_DuctFittingOccurrence" Description="Duct fitting occurrence attributes." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcDuctFitting">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="InteriorRoughnessCoefficient_3WzQo0qTqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasLiner_3cKlS0qTqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Colour_3h5wi0qTqHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3nfYA0qTqHuO00025QrE$V" Name="Pset_DuctFittingPHistory" Description="Duct fitting performance history common attributes." TemplateType="pset_performancedriven" ApplicableEntity="IfcDuctFitting">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="LossCoefficient_3sQjQ0qTqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AtmosphericPressure_3upJ20qTqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AirFlowLeakage_3xBug0qTqHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3$MwW0qTqHuO00025QrE$V" Name="Pset_DuctFittingTypeCommon" Description="Duct fitting type common attributes." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDuctFitting">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_09VQQ0qTuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PressureClass_0M0Vy0qTuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PressureRange_0QnhC0qTuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TemperatureRange_0XxS40qTuHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0gHVm0qTuHuO00025QrE$V" Name="Pset_DuctSegmentOccurrence" Description="Duct segment occurrence attributes attached to an instance of IfcDuctSegment." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcDuctSegment">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="InteriorRoughnessCoefficient_0kSXc0qTuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasLiner_0qP$g0qTuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Colour_3h5wi0qTqHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="14Vze0qTuHuO00025QrE$V" Name="Pset_DuctSegmentPHistory" Description="Duct segment performance history common attributes." TemplateType="pset_performancedriven" ApplicableEntity="IfcDuctSegment">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="LossCoefficient_1BfkW0qTuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AtmosphericPressure_1FEcy0qTuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LeakageCurveHistory_1IpVO0qTuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FluidFlowLeakage_1QZPg0qTuHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1X7180qTuHuO00025QrE$V" Name="Pset_DuctSegmentTypeCommon" Description="Duct segment type common attributes." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDuctSegment">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_1hrgS0qTuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CrossSectionShape_1z7xE0qTuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WorkingPressure_2C1cO0qTuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PressureRange_2HOx20qTuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TemperatureRange_2S7aM0qTuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LongitudinalSeam_2ZHLE0qTuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalDiameterOrWidth_2eefu0qTuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalHeight_2mOaA0qTuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reinforcement_2syBe0qTuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReinforcementSpacing_2yvfi0qTuHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="343Qa0qTuHuO00025QrE$V" Name="Pset_DuctSilencerPHistory" Description="Duct silencer performance history common attributes." TemplateType="pset_performancedriven" ApplicableEntity="IfcDuctSilencer">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="AirFlowRate_3A0ue0qTuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AirPressureDropCurve_3EBwU0qTuHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3IMyK0qTuHuO00025QrE$V" Name="Pset_DuctSilencerTypeCommon" Description="Duct silencer type common attributes.
InsertionLoss and RegeneratedSound attributes deleted in IFC2x2 Pset Addendum: Use IfcSoundProperties instead." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDuctSilencer">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_3T5be0qTuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HydraulicDiameter_3la9E0qTuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Length_3WM1Y0qTCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Weight_3v6Vk0qTuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AirFlowRateRange_3_TqO0qTuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WorkingPressureRange_06Dkg0qTyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TemperatureRange_0F9xm0qTyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasExteriorInsulation_0NV$S0qTyHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="14_x7hXGP8tPRFpQ95awsK" Name="Pset_EarthingElementCommon" Description="Properties common to all types of earthing elements." ApplicableEntity="IfcEarthingElement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Resistivity_0CD1$azajCjeK721qDipOz" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShortCircuitCurrent_1b3j84vif64PjMUuaJihze" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3a70HbGd9ALugG$6vUxua1" Name="Pset_EarthworksCutCommon" Description="Common properties for earthworks cut elements." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcEarthworksCut">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="EarthworksCutExcavationMethod_1dC1DQjIXA4x0mhFKgM7b6" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UserDefinedExcavationMethod_1MCvrSjdH4FhcdbtYwrNpr" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumUnsupportedCut_103uAEL3z7QhsU6g8irstN" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SupportDescription_01gbdSFfjCmwU9fHFwjDV5" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="00rzX06SHBCxWiWDehU$4C" Name="Pset_EarthworksCutTypeTrench" Description="Properties for trenches/sumps." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcEarthworksCut/TRENCH">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="CatchmentArea_2p1YWircfCd8rNYaGGPhaC" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalDepth_0HZnE0qUaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalWidth_2YZfyYRY1Aa9bsWGvZEaNq" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalLength_07RHK0qUaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VolumetricCapacity_0dBcQhjmvDyAJkVkwc0QxW" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0YHku6ForCSPDpmUgu3yAc" Name="Pset_EarthworksFillCommon" Description="Common properties for earthworks fill elements." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcEarthworksFill">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SourceOfFill_1cA5Um37bAPRNMK84NGNf7" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SourceOfFillOther_18ETTPAED9fwUL8dfinr7F" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CompactionMethod_2_UiNQRvH2uuEFFaxMk1It" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CompactionMethodOther_3TT9O2$zXCkB7l$kFVljGC" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CompactionFactor_3IBdqSmXf1vwj5iylqG2hi" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0UfmK0qTyHuO00025QrE$V" Name="Pset_ElectricalDeviceCommon" Description="A collection of properties that are commonly used by electrical device types." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDistributionElement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="RatedCurrent_1uJPqXHDH0jRCEAj47O9L8" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RatedVoltage_2YuL_rvIv9uxXdCK0Vu7_6" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalFrequencyRange_3scdbKLST8Ge9QL74TErgy" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PowerFactor_3FKZGrWnL47wR1V9jblsAW" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConductorFunction_3vDX0hr89BVhc9fLSUDJTm" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfPoles_1BMno0qTyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasProtectiveEarth_1Gk6S0qTyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InsulationStandardClass_1TFB_0qTyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IP_Code_1MhaW0qTyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IK_Code_2kpG9_rK93LwNz4pCQcRnH" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EarthingStyle_31GzGB0Kz6DfNA40OdlMGX" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HeatDissipation_0lf5nUXkv7RfqST9JcFatz" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Power_13VYb5tj10cOr5hZsTbt3R" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalPowerConsumption_0PrrQ0qSaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfPowerSupplyPorts_2zCP6ydR933h5ygkKmdVFt" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FireRating_0eTJm0qT0HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3NQ7IjZWxFup1h$pPHmPJT" Name="Pset_ElectricalDeviceCompliance" Description="Properties related to information about compliance to standards or regulations of electric devices." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDistributionElement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ElectroMagneticStandardsCompliance_2waDzwzkPEmfBnDmVCqDVK" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ExplosiveAtmosphereStandardsCompliance_35VZpD_jv1UwHKJjegrTFR" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FireProofingStandardsCompliance_1iAbIgVqX9OPjRqWkzGyLL" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LightningProtectionStandardsCompliance_1nPkqapDrE3gFjVeVrNyIv" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="301fehHw1k9DOwIddh7E4r" Name="Pset_ElectricalFeederLine" Description="Properties of conductors used as feeder line. This property set is applicable to a type or occurrence of _IfcCableSegment_ with predefined type CONDUCTORSEGMENT." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCableSegment/CONDUCTORSEGMENT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="CurrentCarryingCapacity_2bRJDYSdX00x51ZO5f_6Kl" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DesignAmbientTemperature_1L_xLZOQ911A3ajJsEJF$L" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ElectricalClearanceDistance_3by6kXTBP1n8YEJ6ADRLhV" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ElectricalFeederType_35eHZrPkfE3fcLpjm1KsIK" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1kXSm0qTyHuO00025QrE$V" Name="Pset_ElectricAppliancePHistory" Description="Captures realtime information for electric appliances, such as for energy usage. HISTORY: Added in IFC4." TemplateType="pset_performancedriven" ApplicableEntity="IfcElectricAppliance">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="PowerState_1nWBo0qTyHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1rhDe0qTyHuO00025QrE$V" Name="Pset_ElectricApplianceTypeCommon" Description="Common properties for electric appliances.  HISTORY: Added in IFC4." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcElectricAppliance">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_23_lO0qTyHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2aAhK0qTyHuO00025QrE$V" Name="Pset_ElectricApplianceTypeDishwasher" Description="Common properties for dishwasher appliances. HISTORY: Added in IFC4." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcElectricAppliance/DISHWASHER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="DishwasherType_2mhms0qTyHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="36lCu0qTyHuO00025QrE$V" Name="Pset_ElectricApplianceTypeElectricCooker" Description="Common properties for electric cooker appliances. HISTORY: Added in IFC4." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcElectricAppliance/ELECTRICCOOKER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ElectricCookerType_3BWO80qTyHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="07s9zrreYF4mvuqckLWPME" Name="Pset_ElectricFlowStorageDeviceTypeBattery" Description="Properties of batteries. The property set can be used by the predefined type BATTERY of IfcElectricFlowStorageDevice." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcElectricFlowStorageDevice/BATTERY">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="CurrentRegulationRate_0hIDL7tBjFU81u978zIqML" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalSupplyCurrent_3hgdbiYpLERhPeEQfTel7i" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VoltageRegulationRate_2JurpF5$z9eRwfdnERHveS" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AssemblyInstruction_3W5i6nbkP9NBt_M6PTB5jW" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BatteryChargingType_1gCweXW9v248GPX0vRTL$f" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EncapsulationTechnologyCode_17B_9r6_5FWwAMTe_Dht3b" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OpenCircuitVoltage_2Qhz7hntj8tvEhto7ffFga" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RechargeTime_0t1t$3NL5CXB4ArojrVPpo" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RuntimeAtFullLoad_1Wa6XnYx56p8rACT$SifuH" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumShortCircuitCurrent_13Pj5R2Dr2uufzGEqODIOX" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="30We2CI1bnoKwuXPwfRdUF" Name="Pset_ElectricFlowStorageDeviceTypeCapacitor" Description="Properties of capacitors. The property set can be used by the predefined type CAPACITOR of IfcElectricFlowStorageDevice." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcElectricFlowStorageDevice/CAPACITOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfPhases_1BIplyxBLFfuml0KvHZ1y2" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0BuG00qU0HuO00025QrE$V" Name="Pset_ElectricFlowStorageDeviceTypeCommon" Description="The characteristics of the supply associated with an electrical device occurrence acting as a source of supply to an electrical distribution system NOTE: Properties within this property set should ONLY be used in circumstances when an electrical supply is applied. The property set, the properties contained and their values are not applicable to a circumstance where the sypply  is not being applied to the eletrical system or is temporarily disconnected. All properties within this property set are considered to represent a steady state situation." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcElectricFlowStorageDevice">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_0ND2k0qU0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalSupplyVoltage_0f5Sw0qU0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalSupplyVoltageOffset_0kSna0qU0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalFrequency_0rcYS0qU0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConnectedConductorFunction_0zyc80qU0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShortCircuit3PoleMaximumState_1H1J80qU0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShortCircuit3PolePowerFactorMaximumState_1M_nC0qU0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShortCircuit2PoleMinimumState_1SM5s0qU0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShortCircuit2PolePowerFactorMinimumState_1ai9Y0qU0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShortCircuit1PoleMaximumState_1saZk0qU0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShortCircuit1PolePowerFactorMaximumState_1zkKc0qU0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShortCircuit1PoleMinimumState_23hog0qU0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShortCircuit1PolePowerFactorMinimumState_2937K0qU0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EarthFault1PoleMaximumState_2DqIa0qU0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EarthFault1PolePowerFactorMaximumState_2JBdE0qU0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EarthFault1PoleMinimumState_2NyoU0qU0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EarthFault1PolePowerFactorMinimumState_2TK780qU0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumInsulatedVoltage_1Rmq9PJnfEKuHYQTF1jjZg" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RatedCapacitance_2Kimec$1fFleqiGj$Fg9HN" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PowerCapacity_1mAfVHVQfDtBcb3$W2OBiX" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfPhases_1BIplyxBLFfuml0KvHZ1y2" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1wRgXgmYZNYrROEAQkOVUn" Name="Pset_ElectricFlowStorageDeviceTypeInductor" Description="Properties of inductors. The property set can be used by the predefined type INDUCTOR of IfcElectricFlowStorageDevice." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcElectricFlowStorageDevice/INDUCTOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Inductance_26NOHc5AHAsRdIVv$vqQ_g" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfPhases_1BIplyxBLFfuml0KvHZ1y2" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3Uhko0UUqN4OntOHE97kTk" Name="Pset_ElectricFlowStorageDeviceTypeRecharger" Description="Properties of battery rechargers. The property set can be used by the predefined type RECHARGER of IfcElectricFlowStorageDevice." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcElectricFlowStorageDevice/RECHARGER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalSupplyCurrent_3hgdbiYpLERhPeEQfTel7i" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1E_mlVzrnSDt6FWMFHF7jN" Name="Pset_ElectricFlowStorageDeviceTypeUPS" Description="Properties of uninterruptible power supply equipment. The property set can be used by the predefined type UPS of IfcElectricFlowStorageDevice." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcElectricFlowStorageDevice/UPS">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="AssemblyInstruction_3W5i6nbkP9NBt_M6PTB5jW" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CurrentRegulationRate_0hIDL7tBjFU81u978zIqML" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalSupplyCurrent_3hgdbiYpLERhPeEQfTel7i" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VoltageRegulationRate_2JurpF5$z9eRwfdnERHveS" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="36$b2864Vi8E84mteD9feD" Name="Pset_ElectricFlowTreatmentDeviceTypeElectronicFilter" Description="Properties associated to electronic filter.
An electronic filter is a device designed to transmit spectral components of signals according to a specified law, generally in order to pass the components in certain frequency bands and to attenuate those in other bands (IEC702-09-17)" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcElectricFlowTreatmentDevice/ELECTRONICFILTER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalPower_2pu16hiH1CqQv04BNgxAph" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ElectronicFilterType_1CfK$TChb3WvEVYC2jfIpk" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalCurrent_0sDhk0qUWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PrimaryFrequency_1tZv40qX4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SecondaryFrequency_1_7WY0qX4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RatedVoltage_0_oie0qSSHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2YhRo0qU0HuO00025QrE$V" Name="Pset_ElectricGeneratorTypeCommon" Description="Defines a particular type of engine that is a machine for converting mechanical energy into electrical energy." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcElectricGenerator">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_2jQ560qU0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ElectricGeneratorEfficiency_2x7TS0qU0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="StartCurrentFactor_30Uo60qU0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumPowerOutput_35FzM0qU0HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3AdI00qU0HuO00025QrE$V" Name="Pset_ElectricMotorTypeCommon" Description="Defines a particular type of engine that is a machine for converting electrical energy into mechanical energy. Note that in cases where a close coupled or monobloc pump or close coupled fan is being driven by the motor, the motor may itself be considered to be directly part of the pump or fan. In this case , motor information may need to be specified directly at the pump or fan and not througfh separate motor/motor connection entities. NOTE: StartingTime and TeTime added at IFC4" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcElectricMotor">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_3N8NY0qU0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumPowerOutput_3bRvI0qU0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ElectricMotorEfficiency_3fcx80qU0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="StartCurrentFactor_3k_Fo0qU0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="StartingTime_3p9He0qU0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TeTime_3uWcI0qU0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LockedRotorCurrent_3ztwy0qU0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MotorEnclosureType_02f6C0qU4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FrameSize_0FmL80qU4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsGuarded_0LjpC0qU4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasPartWinding_0R57s0qU4HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0WSSW0qU4HuO00025QrE$V" Name="Pset_ElectricTimeControlTypeCommon" Description="Common properties for electric time control devices. HISTORY: Added in IFC4." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcElectricTimeControl">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_0hnFE0qU4HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0FFkv1bQb5xBumBg6nZobE" Name="Pset_ElementAssemblyCommon" Description="Properties common to the definition of all occurrence and type objects of element assembly." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcElementAssembly">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_0Wvqzvq7L0UfBvFMU8A1Co" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="11X$RzPJRL6M42wEhleOGb" Name="Pset_ElementAssemblyTypeCantilever" Description="Energy cantilever properties used in railway. The property set can be used by the predefined type SUSPENSION_ASSEMBLY of IfcElementAssembly." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcElementAssembly/SUSPENSIONASSEMBLY">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="AssemblyInstruction_3W5i6nbkP9NBt_M6PTB5jW" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ContactWireStagger_1dWD_52DDFheUkLfvK_Wga" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ContactWireNominalDrop_0PafkcBBDBPAuLjLmX5W1c" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CantileverType_0XTiJJXGr1wO0ECA2JlUwp" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3KC7gnoBhcMiPovszDe8IS" Name="Pset_ElementAssemblyTypeDilatationPanel" Description="Adjustment switch panel properties used in railway. The property set can be used by the predefined type DILATATION_PANEL of IfcElementAssembly." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcElementAssembly/DILATATIONPANEL">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="TechnicalStandard_2M$Q1oBlHFBhUArnmHLc4W" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DilatationLength_32bfxZV9DAqf890UR2MfrM" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ExpansionDirection_2DxkIX5iv4mB2_uToCgx$W" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InstallationPlan_1$TLUfKkH5dRWTorjafyVb" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BladesOrientation_1$5SWy5mf8nPhe9jueRr_a" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3_sQZQDQWS52VeiSS18fyO" Name="Pset_ElementAssemblyTypeHeadSpan" Description="Energy Head Span properties used in railway. The property set can be used by the predefined type SUSPENSION_ASSEMBLY of IfcElementAssembly." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcElementAssembly/SUPPORTINGASSEMBLY">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="AssemblyInstruction_3W5i6nbkP9NBt_M6PTB5jW" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfTracksCrossed_0tJ0zrZfrEWfrDbpRcmd38" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Span_0PY8o0qSGHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3LcGsKP9YRaKHzOfCul2sW" Name="Pset_ElementAssemblyTypeMast" Description="Telecom Tower properties used in railway. The property set can be used by the predefined type MAST of IfcElementAssembly." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcElementAssembly/MAST">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="WithLightningRod_3pPNiRy4X9KvANfnRk92$0" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2DCtEEP_LeLsne9cfraXjM" Name="Pset_ElementAssemblyTypeOCSSuspension" Description="Common energy suspension properties used in railway. The property set can be used by the predefined type SUSPENSION_ASSEMBLY of IfcElementAssembly." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcElementAssembly/SUSPENSIONASSEMBLY">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ContactWireStagger_1dWD_52DDFheUkLfvK_Wga" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ContactWireNominalHeight_1WIgSUjRrA2vcLynsmAyg4" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0SRU92ZEjFHf7uy7BMfG24" Name="Pset_ElementAssemblyTypePreSupportFace" Description="Properties for element assemblies of type PRESUPPORTFACE." ApplicableEntity="IfcElementAssembly/.PRESUPPORTFACE.">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="TransverseBoreholeSpacing_1vnl8FJyvCguD4Xq4zJz5Q" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VerticalBoreholeSpacing_23Yy5aOIfFZwpwj5Oj4J3v" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="00WdWNAKP8nfzN5KosahCm" Name="Pset_ElementAssemblyTypePreSupportVault" Description="Properties for element assemblies of type PRESUPPORTVAULT." ApplicableEntity="IfcElementAssembly/.PRESUPPORTVAULT.">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="BoreholeGradient_225RK5rBrEBAwcf$dqwrFh" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RadialSpacing_25znbD5O93kQ8QwsBqr1oq" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VaultOffset_2UKv6rv1538Phe36azkgWO" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1ZXPn6ufE2b1UgpFJ54_qS" Name="Pset_ElementAssemblyTypeRigidFrame" Description="Energy Cross Beam properties used in railway. The property set can be used by the predefined type RIGID_FRAME of IfcElementAssembly." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcElementAssembly/RIGID_FRAME">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="AssemblyInstruction_3W5i6nbkP9NBt_M6PTB5jW" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LoadCapacity_1_J9Z6hsjADva_RGdwfJlg" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfTracksCrossed_0tJ0zrZfrEWfrDbpRcmd38" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Span_0PY8o0qSGHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="19sRqIi$vEvfkMjkOsCUvX" Name="Pset_ElementAssemblyTypeRing" Description="Enumeration of the different types of rings." ApplicableEntity="IfcElementAssembly/(.RING.)">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="RingType_19mOtbL$f8jRVRPXORtt$x" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2z3rZfwk4scROltRQxK1Qy" Name="Pset_ElementAssemblyTypeSteadyDevice" Description="Energy steady device properties used in railway. The property set can be used by the predefined type SUSPENSION_ASSEMBLY of IfcElementAssembly." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcElementAssembly/SUSPENSIONASSEMBLY">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="AssemblyInstruction_3W5i6nbkP9NBt_M6PTB5jW" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ContactWireStagger_1dWD_52DDFheUkLfvK_Wga" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsSetOnWorkingWire_3iDlFQIQvDTx70HJm6uraY" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SteadyDeviceType_1vPh$B_I5FigMapMG3Ne8f" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0C40JUCkbZ3GDIhNha76Ym" Name="Pset_ElementAssemblyTypeSupportingAssembly" Description="Energy supporting assembly properties used in railway. The property set can be used by the predefined type SUPPORTING_ASSEMBLY of IfcElementAssembly." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcElementAssembly/SUPPORTINGASSEMBLY">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfCantilevers_2KK5NTKab9_g7iM9ioqV$u" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TypeOfSupportingSystem_3WKZxWJOXCiOu_tvXdPAUd" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1$E63suyTWAWhxzhV2L$4o" Name="Pset_ElementAssemblyTypeTrackPanel" Description="Track panel properties used in railway. The property set can be used by the predefined type TRACK_PANEL of IfcElementAssembly." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcElementAssembly/TRACKPANEL">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsAccessibleByVehicle_3R5N45JWj9UumSu_fUKeWz" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TrackExpansion_0vaUGKvwPBQhk6i2nO$f86" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InstallationPlan_1$TLUfKkH5dRWTorjafyVb" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2GMDb5CNhQpMAjUZ1NGRB4" Name="Pset_ElementAssemblyTypeTractionSwitchingAssembly" Description="Energy switching assembly properties used in railway. The property set can be used by the predefined type TRACTION_SWITCHING_ASSEMBLY of IfcElementAssembly." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcElementAssembly/TRACTION_SWITCHING_ASSEMBLY">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalCurrent_1Vh1C0qVaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalPower_2pu16hiH1CqQv04BNgxAph" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RatedVoltage_0_oie0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DesignAmbientTemperature_1L_xLZOQ911A3ajJsEJF$L" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1qwe3gcSHE2A7dTXirX8FY" Name="Pset_ElementAssemblyTypeTurnoutPanel" Description="Turnout panel properties used in railway. The property set can be used by the predefined type TURNOUT_PANEL of IfcElementAssembly." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcElementAssembly/TURNOUTPANEL">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsAccessibleByVehicle_3R5N45JWj9UumSu_fUKeWz" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BranchLineDirection_22jf5Fjrb7QQNs0siCGIsQ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TrackExpansion_0vaUGKvwPBQhk6i2nO$f86" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TurnoutCurvedRadius_3FY$OPu$b6J8ZMO7JXyrJe" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TypeOfCurvedTurnout_290PDCxijBugy3g08gwk5i" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InstallationPlan_1$TLUfKkH5dRWTorjafyVb" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsSharedTurnout_3ZDLci8DP06u1$Ft52yrEN" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumSpeedLimitOfDivergingLine_3kTbdyPPL0ve7aTOCf7Kan" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TypeOfDrivingDevice_18PeDiUi91sfJJk$VA50EV" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TrackElementOrientation_13xvT88Cz9wRdASN0W90_H" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PercentShared_27XpU_GB5Ai8wh8ZfdIOsh" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TrackGaugeLength_1v1Jj1_hn3HRQxYEGOBxy0" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TurnoutPointMachineCount_249Cywch9BU9fEWCgPdORK" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TurnoutHeaterType_27rZtIRVj5GBgj9RvjETkL" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TypeOfJunction_1CPJkVojL2mf9DeSn$IYKu" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TypeOfTurnout_2OfaIDftHCpO$ERd0KXnMa" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1$kUwEqwL2BvJ_iHWNGoOf" Name="Pset_ElementCommon" Description="This property set serves as a placeholder for common properties to assist in translation, and is not currently published (the property set type is set to NOTDEFINED)." ApplicableEntity="IfcElement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_33frgWW4D3euBRuniN2rSn" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_2fCvAGBpr3x8S7N8rZtpnP" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1bPCSD$RLA4e7G5ZhHHhly" Name="Pset_ElementComponentCommon" Description="Set of common properties of component elements (especially discrete accessories, but also fasteners, reinforcement elements, or other types of components)." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcElementComponent">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_1My8v0zEn4Hek5k3AKjbvV" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DeliveryType_0fBrsqCsvBCPwzsHeQjPIh" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CorrosionTreatment_3tiPdiQHXE1RcerDmwYVRN" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1oSYaA1aH5ReUtAERZCIfN" Name="Pset_ElementKinematics" Description="Information confirming that the element has cyclic and/or pathed kinematic behaviour. The resulting envelope may be available as a &apos;clearance&apos; shape representation." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcElement,IfcElementType">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="CyclicPath_2_sY8JfBfFRhE6m4raua0C" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CyclicRange_3O_8A2txvFWP$Mo9_vRrzI" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LinearPath_1Pz9ucT1f6ex16eSfaPgQ$" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LinearRange_2LCLSUKZH99hoSPDQYRgwF" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumAngularVelocity_2PbvOcZIjFyhgvTPRNHKi4" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumConstantSpeed_2GnYKK37P2XxUFvvgs8uSy" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MinimumTime_0WfkXHCXn70fx5kt6ZEVKM" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="20_PjAa6PAcxmd$X$7AjVa" Name="Pset_ElementSize" Description="Property set with properties about size of the element." ApplicableEntity="IfcDistributionChamberElement,IfcEnergyConversionDevice,IfcFlowController,IfcFlowMovingDevice,IfcFlowStorageDevice,IfcFlowTerminal,IfcFlowTreatmentDevice">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalLength_3OohBqhOr7qe_LKHtDErK8" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalWidth_2aB9t8l_fBruh$Sc_$ZTMJ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalHeight_19lK0$_1v7UxYDTioABcJZ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalThickness_2QgJLpWOb3xfvwr_YO$T_k" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalDiameter_2EWhC0qX8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalWeight_1NkoWVgmHA5xrENqUppTds" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1dFO8dKbjAahfs2VsG8atr" Name="Pset_EmbeddedTrack" Description="Properties for track slab that have embedded tracks recessed into road surface." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSlab/TRACKSLAB">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsAccessibleByVehicle_3R5N45JWj9UumSu_fUKeWz" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasDrainage_30Z3LZrU15p9CBV6oSf4at" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PermissibleRoadLoad_0dZw4UYSDFVPrQibCUZruL" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2m0ZBo8GnEnPmKRFWLGgf7" Name="Pset_EnergyRequirements" Description="Property set for the application of energy requirements to facility and physical elements" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDistributionElement,IfcTransportationDevice">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="EnergyConsumption_2FStwk6UX5ThoaIOB4preA" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PowerDemand_1FaUfs_7b2qQdwXAs_k3m$" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EnergySourceLabel_1mlnyMavn0XvUzU0A9esFc" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EnergyConversionEfficiency_0Q_KpfMv19ewQMdEiBbY7K" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="14DGu0qU4HuO00025QrE$V" Name="Pset_EngineTypeCommon" Description="Engine type common attributes." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcEngine">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_1FY3c0qU4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EnergySource_1Ve1a0qU4HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3t33MdTJIcbl0LWHXpEfQh" Name="Pset_EnvironmentalCondition" Description="Properties defining environment conditions required by the element." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcElement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReferenceAirRelativeHumidity_1wG8Xp53PDOPLBMvLK0g1J" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReferenceEnvironmentTemperature_2vgOshA4D0$ems5HSBwemr" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumAtmosphericPressure_0Qno0T109Cww7r$cstWuI3" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="StorageTemperatureRange_0T6ELr2bv1MP48HEd_Ue3i" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumWindSpeed_1btB4PB6T4pQcpyRRarqLn" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OperationalTemperatureRange_2_eMO0qS0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumRainIntensity_1HJs_aZFnBKP1bnlrIzkxt" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SaltMistLevel_3rzK_24B55FhlIh99zlW26" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SeismicResistance_17fvYJ58159gRnjvJMIylv" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SmokeLevel_24x_PWjRXByRIpwhg2SIFm" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumSolarRadiation_3GwIZXL0151QO$6Rwbh8Tj" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3_6fELwub59fZV_Fput0sL" Name="Pset_EnvironmentalEmissions" Description="Property set for the application of energy emissions produced by facility and physical elements." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDistributionElement,IfcTransportationDevice">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="CarbonDioxideEmissions_0qzq4eq5DDfAgxx_gs$ue9" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SulphurDioxideEmissions_3$COjWkL9EsA4nTJCFPmTb" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NitrogenOxidesEmissions_1Y8SA6Uc98dRtm7sZssBm_" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ParticulateMatterEmissions_0PYDfb7nz3$hoT9UBbWKgS" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NoiseEmissions_0Quf032kD2sP$S5x5qU4Gx" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1xexg0qU4HuO00025QrE$V" Name="Pset_EnvironmentalImpactIndicators" Description="Environmental impact indicators are related to a given “functional unit” (ISO 14040 concept). An example of functional unit is a &quot;Double glazing window with PVC frame&quot; and the unit to consider is &quot;one square meter of opening elements filled by this product”.
Indicators values are valid for the whole life cycle or only a specific phase (see LifeCyclePhase property). Values of all the indicators are expressed per year according to the expected service life. The first five properties capture the characteristics of the functional unit. The following properties are related to environmental indicators.
There is a consensus agreement international for the five one. Last ones are not yet fully and formally agreed at the international level." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcElement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FunctionalUnitReference_28A1C0qU4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IndicatorsUnit_2FJo40qU4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LifeCyclePhase_2MTYy0qU4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ExpectedServiceLife_2dlpk0qU4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TotalPrimaryEnergyConsumptionPerUnit_2jjHo0qU4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WaterConsumptionPerUnit_2p4cS0qU4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HazardousWastePerUnit_2v24W0qU4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NonHazardousWastePerUnit_2_PPA0qU4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ClimateChangePerUnit_33AaQ0qU4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AtmosphericAcidificationPerUnit_3982U0qU4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RenewableEnergyConsumptionPerUnit_3F5WY0qU4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NonRenewableEnergyConsumptionPerUnit_3L2_c0qU4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ResourceDepletionPerUnit_3R0Sg0qU4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InertWastePerUnit_3Wzwk0qU4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RadioactiveWastePerUnit_3cxOo0qU4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="StratosphericOzoneLayerDestructionPerUnit_3iIjS0qU4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PhotochemicalOzoneFormationPerUnit_3osKw0qU4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EutrophicationPerUnit_3tdWA0qU4HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3_B7e0qU4HuO00025QrE$V" Name="Pset_EnvironmentalImpactValues" Description="The following properties capture environmental impact values of an element. They correspond to the indicators defined into Pset_EnvironmentalImpactIndicators.
Environmental impact values are obtained multiplying indicator value per unit by the relevant quantity of the element." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcElement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="TotalPrimaryEnergyConsumption_048bi0qU8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WaterConsumption_09VwM0qU8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HazardousWaste_0FTOQ0qU8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NonHazardousWaste_0Kqj40qU8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ClimateChange_0QC1k0qU8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AtmosphericAcidification_0VZMO0qU8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RenewableEnergyConsumption_0bWqS0qU8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NonRenewableEnergyConsumption_0gu960qU8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ResourceDepletion_0mFTm0qU8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InertWaste_0rcoQ0qU8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RadioactiveWaste_0xaGU0qU8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="StratosphericOzoneLayerDestruction_10xb80qU8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PhotochemicalOzoneFormation_16v3C0qU8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Eutrophication_1CsXG0qU8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LeadInTime_2u_yRtXmj8Re3DPXkTqC9y" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Duration_2rj9qW2$99f9rLZEzwotMz" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LeadOutTime_28wkDLvzz6IeIRvXElIFeo" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1Ip$K0qU8HuO00025QrE$V" Name="Pset_EvaporativeCoolerPHistory" Description="Evaporative cooler performance history attributes." TemplateType="pset_performancedriven" ApplicableEntity="IfcEvaporativeCooler">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="WaterSumpTemperature_1OBJ_0qU8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Effectiveness_1SMLq0qU8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SensibleHeatTransferRate_1VL4s0qU8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LatentHeatTransferRate_1YvzI0qU8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TotalHeatTransferRate_1buiK0qU8HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1g3kA0qU8HuO00025QrE$V" Name="Pset_EvaporativeCoolerTypeCommon" Description="Evaporative cooler type common attributes.
Sound attribute deleted in IFC2x2 Pset Addendum: Use IfcSoundProperties instead. WaterRequirement attribute unit type modified in IFC2x2 Pset Addendum." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcEvaporativeCooler">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_1sapi0qU8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FlowArrangement_264eG0qU8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HeatExchangeArea_2Jo0c0qU8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OperationTemperatureRange_2P9LG0qU8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WaterRequirement_2Y5YM0qU8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EffectivenessTable_2dSt00qU8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AirPressureDropCurve_2nbMw0qU8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WaterPressDropCurve_2yw9e0qU8HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="38r5m0qU8HuO00025QrE$V" Name="Pset_EvaporatorPHistory" Description="Evaporator performance history attributes." TemplateType="pset_performancedriven" ApplicableEntity="IfcEvaporator">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="HeatRejectionRate_3ECQQ0qU8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ExteriorHeatTransferCoefficient_3HB9S0qU8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InteriorHeatTransferCoefficient_3Km1u0qU8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RefrigerantFoulingResistance_3Ox3k0qU8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EvaporatingTemperature_3Rvom0qU8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LogarithmicMeanTemperatureDifference_3UuXo0qU8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UAcurves_3XtGq0qU8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CompressorEvaporatorHeatGain_3k_Vm0qU8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CompressorEvaporatorPressureDrop_3plh00qU8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EvaporatorMeanVoidFraction_3uWsG0qU8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WaterFoulingResistance_3y5ki0qU8HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="00GmY0qUCHuO00025QrE$V" Name="Pset_EvaporatorTypeCommon" Description="Evaporator type common attributes." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcEvaporator">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_0CBig0qUCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EvaporatorMediumType_0RhXE0qUCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EvaporatorCoolant_0eomA0qUCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RefrigerantClass_0vUtY0qUCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ExternalSurfaceArea_1G8S_0qUCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InternalSurfaceArea_1Mi4S0qUCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InternalRefrigerantVolume_1S3P60qUCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InternalWaterVolume_1XQjm0qUCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalHeatTransferArea_1dOBq0qUCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalHeatTransferCoefficient_1jLfu0qUCHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1gXAvJEtDD8hQljSKTDyec" Name="Pset_ExcavationCommon" Description="Common properties for Excavations." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcUndergroundExcavation">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="BulkingFactor_3Uxd60AAr21eGcLI8RmIS$" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3IkA9tu057t8CgH5EUcobw" Name="Pset_FaceExcavationCommon" Description="Common properties for face excavation elements." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcUndergroundExcavation/FACEEXCAVATION">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="FaceExcavationType_2bpyAfLPD1KPvgab$9KTzT" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsDriveDirectedAlongChainage_3rVlZS58jDAw9PXxvdgGeO" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TunnelInclination_2$VkG7ESn3rQ2WJSlegUBN" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DriveInclination_3wCXCi1srD59Rj89Iug8_e" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ExcavationFaceInclination_0KcNnRVov7v8l33uxXOfnq" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaxUnsupportedExcavationLength_1coGhCQG56WRQyuTdAF2Vg" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1qVQm0qUCHuO00025QrE$V" Name="Pset_FanCentrifugal" Description="Centrifugal fan occurrence attributes attached to an instance of IfcFan." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcFan/CENTRIFUGALAIRFOIL,IfcFan/CENTRIFUGALBACKWARDINCLINEDCURVED,IfcFan/CENTRIFUGALFORWARDCURVED,IfcFan/CENTRIFUGALRADIAL">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="DischargePosition_1yrUS0qUCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DirectionOfRotation_2KhMi0qUCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FanArrangement_2YOl20qUCHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2wqmi0qUCHuO00025QrE$V" Name="Pset_FanOccurrence" Description="Fan occurrence attributes attached to an instance of IfcFan." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcFan">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="DischargeType_2_$oY0qUCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ApplicationOfFan_3Fhvw0qUCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoilPosition_3WO1I0qUCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MotorPosition_3iv6q0qUCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FanMountingType_3w0Lm0qUCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FractionOfMotorHeatToAirStream_0D52m0qUGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ImpellerDiameter_0ISNQ0qUGHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0QoR60qUGHuO00025QrE$V" Name="Pset_FanPHistory" Description="Fan performance history attributes.
&gt; IFC2X2 CHANGE&amp;nbsp; Sound attribute deleted in IFC2x2 Pset Addendum: Use IfcSoundProperties instead." TemplateType="pset_performancedriven" ApplicableEntity="IfcFan">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="FanRotationSpeed_0W9lm0qUGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WheelTipSpeed_0ZkeC0qUGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FanEfficiency_0cjNE0qUGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OverallEfficiency_0fi6G0qUGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FanPowerRate_0igrI0qUGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShaftPowerRate_0mFjk0qUGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DischargeVelocity_0pqcA0qUGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DischargePressureLoss_0spLC0qUGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DrivePowerLoss_0wODe0qUGHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0$9Ou0qUGHuO00025QrE$V" Name="Pset_FanTypeCommon" Description="Fan type common attributes." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcFan">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_1B4L00qUGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MotorDriveType_1RAI_0qUGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CapacityControlType_1g3_80qUGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OperationTemperatureRange_1wm5W0qUGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalAirFlowRate_2369C0qUGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalTotalPressure_293dG0qUGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalStaticPressure_2GpXY0qUGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalRotationSpeed_2Mm$c0qUGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalPowerRate_2RYAs0qUGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OperationalCriteria_2WvVW0qUGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PressureCurve_2csza0qUGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EfficiencyCurve_2oBmI0qUGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EfficiencyPoint_2cbW2T9CPEk9B$EXGpp6o5" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="StaticLoad_35jL348fLEw8Qtk01HBCmU" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DynamicLoad_1mwsvedSD15w8oYBVVJ6aM" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0Hs4S4gX155Af$KYioPMNX" Name="Pset_FanTypeJet" Description="Properties for fans of type JET." ApplicableEntity="IfcFan/JET">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalThrust_0473J1zsPCffpkaV4GfAVV" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EffectiveThrust_1ekGiZJAP4nBsEk83RlhQT" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0dwkGI4jpP_IcX5NYj5Fr1" Name="Pset_FastenerRailWeld" Description="Properties of Welded rail joint used in railway. The property set can be used by the predefined type WELD of IfcFastener." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcFastener/WELD">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsLiftingBracket_0Py8wuJJrAwPXDvufAW9rN" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TemperatureDuringInstallation_3vvVR5txv9mvLBcLLN7XJV" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="JointRelativePosition_06BnzJB6b9zhMKCUAtPkfJ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AssemblyPlace_1YL3k0qUmHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2zWZ00qUGHuO00025QrE$V" Name="Pset_FastenerWeld" Description="Properties related to welded connections." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcFastener/WELD">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Type1_35GTI0qUGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Type2_3CQEA0qUGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Surface1_3INiE0qUGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Surface2_3OLAI0qUGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Process_3VUxA0qUGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ProcessName_3asFq0qUGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalThroatThickness_3gpju0qUGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WeldWidth_3p9na0qUGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WeldDiameter_3vjP20qUGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WeldElementSpacing_00t9w0qUKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WeldElementLength_07QnO0qUKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfWeldElements_0EaYG0qUKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DeepPenetrationThroatThickness_0JLjW0qUKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WeldLegLength_0QVUO0qUKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Intermittent_0XfFG0qUKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Staggered_0eCsk0qUKHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0XaP$P9FX92PDLbOb_FqDs" Name="Pset_FenderCommon" Description="Properties common to the definition of all occurrences of _IfcImpactProtectionDevice_ and types of _IfcImpactProtectionDeviceType_ with the predefined type set to FENDER." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcImpactProtectionDevice/FENDER,IfcImpactProtectionDeviceType/FENDER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="FenderType_3saZ7owb5D$BDYSbnCWq1T" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoefficientOfFriction_2NklEn94fAAffIQBYsYnZD" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EnergyAbsorptionTolerance_1OJ17ugQX03Bd4SHIow6m5" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaxReactionTolerance_0PmqwfTKPD8AogG3WjSaaE" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumTemperatureFactor_3QoL$QX913HhRDcJ6P3D8O" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MinimumTemperatureFactor_0CbyYQjHD6gwW0KlswRtHt" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VelocityFactorEnergy_10SRT1aMv5wwRi4vGIdEF3" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VelocityFactorReaction_2GD9BPt$X6wBvT53fE9sI1" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EnergyAbsorption_3cEXeuXEPEEBpQYb23aZbV" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaxReaction_1I1q26Vcb1Oh7jw1XKWdxF" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3Mx5pKqM93RPNmRB$CPUTQ" Name="Pset_FenderDesignCriteria" Description="Properties common to the definition of design criteria of all occurrences of  _IfcImpactProtectionDevice_ and types of _IfcImpactProtectionDeviceType_ with the predefined type set to FENDER." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSpace/BERTH">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoefficientOfFriction_2NklEn94fAAffIQBYsYnZD" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EnergyAbsorptionTolerance_1OJ17ugQX03Bd4SHIow6m5" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaxReactionTolerance_0PmqwfTKPD8AogG3WjSaaE" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumTemperatureFactor_3QoL$QX913HhRDcJ6P3D8O" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MinimumTemperatureFactor_0CbyYQjHD6gwW0KlswRtHt" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VelocityFactorEnergy_10SRT1aMv5wwRi4vGIdEF3" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VelocityFactorReaction_2GD9BPt$X6wBvT53fE9sI1" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EnergyAbsorption_3cEXeuXEPEEBpQYb23aZbV" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaxReaction_1I1q26Vcb1Oh7jw1XKWdxF" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MinCompressedFenderHeight_2jmteXu49EOgIrz0yF4reQ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AddedMassCoefficientMethod_32KBtk9g1DVge506I8DxMK" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0lMdc0qUKHuO00025QrE$V" Name="Pset_FilterPHistory" Description="Filter performance history attributes." TemplateType="pset_performancedriven" ApplicableEntity="IfcFilter">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="CountedEfficiency_0rK5g0qUKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WeightedEfficiency_0vV7W0qUKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ParticleMassHolding_0yTsY0qUKHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="11F1o0qUKHuO00025QrE$V" Name="Pset_FilterTypeAirParticleFilter" Description="Air particle filter type attributes." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcFilter/AIRPARTICLEFILTER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="AirParticleFilterType_17CVs0qUKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FrameMaterial_1ZDPy0qUKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SeparationType_1cC8_0qUKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DustHoldingCapacity_1qVgk0qUKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FaceSurfaceArea_1vGr_0qUKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MediaExtendedArea_1$qTS0qUKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalCountedEfficiency_25Bo60qUKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalWeightedEfficiency_2AZ6m0qUKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PressureDropCurve_2FwRQ0qUKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CountedEfficiencyCurve_2Q2xK0qUKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WeightedEfficiencyCurve_2bztS0qUKHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2nupa0qUKHuO00025QrE$V" Name="Pset_FilterTypeCommon" Description="Filter type common attributes." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcFilter">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_2xRA40qUKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Weight_3CjQs0qUKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InitialResistance_3I4lW0qUKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FinalResistance_3O2Da0qUKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OperationTemperatureRange_3TPYE0qUKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FlowRateRange_3Zz9i0qUKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalFilterFaceVelocity_3gWnA0qUKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalMediaSurfaceVelocity_3khp00qUKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalPressureDrop_3osqs0qUKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalFlowrate_3uE9W0qUKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalParticleGeometricMeanDiameter_3zbUA0qUKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalParticleGeometricStandardDeviation_02yoq0qUOHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="08K7U0qUOHuO00025QrE$V" Name="Pset_FilterTypeCompressedAirFilter" Description="Compressed air filter type attributes." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcFilter/COMPRESSEDAIRFILTER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="CompressedAirFilterType_0CV9K0qUOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OperationPressureMax_0Npy20qUOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ParticleAbsorptionCurve_0R_zu0qUOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AutomaticCondensateDischarge_0bXKO0qUOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CloggingIndicator_0guf20qUOHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0ms760qUOHuO00025QrE$V" Name="Pset_FilterTypeWaterFilter" Description="Water filter type attributes." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcFilter/WATERFILTER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="WaterFilterType_0r18y0qUOHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="13Kgi0qUOHuO00025QrE$V" Name="Pset_FireSuppressionTerminalTypeBreechingInlet" Description="Symmetrical pipe fitting that unites two or more inlets into a single pipe (BS6100 330 114 adapted)." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcFireSuppressionTerminal/BREECHINGINLET">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="BreechingInletType_19I8m0qUOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InletDiameter_1K0o40qUOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OutletDiameter_1PO6k0qUOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CouplingType_1UlRO0qUOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasCaps_1g4E60qUOHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1m1iA0qUOHuO00025QrE$V" Name="Pset_FireSuppressionTerminalTypeCommon" Description="Common properties for fire suppression terminals." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcFireSuppressionTerminal">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_1uNls0qUOHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2658C0qUOHuO00025QrE$V" Name="Pset_FireSuppressionTerminalTypeFireHydrant" Description="Device, fitted to a pipe, through which a temporary supply of water may be provided (BS6100 330 6107).
For further details on fire hydrants, see www.firehydrant.org" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcFireSuppressionTerminal/FIREHYDRANT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="FireHydrantType_2AGA20qUOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PumperConnectionSize_2KOfy0qUOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfHoseConnections_2QyHQ0qUOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HoseConnectionSize_2VjSg0qUOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DischargeFlowRate_2bgwk0qUOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FlowClass_2gS5_0qUOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WaterIsPotable_2m$jS0qUOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PressureRating_2sN260qUOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BodyColour_2xkMm0qUOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CapColour_30VY00qUOHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3739U0qUOHuO00025QrE$V" Name="Pset_FireSuppressionTerminalTypeHoseReel" Description="A supporting framework on which a hose may be wound (BS6100 155 8201).
Note that the service provided by the hose (water/foam) is determined by the context of the system onto which the hose reel is connected." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcFireSuppressionTerminal/HOSEREEL">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="HoseReelType_3CQU80qUOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HoseReelMountingType_3PXj40qUOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InletConnectionSize_3f1Xe0qUOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HoseDiameter_3k_$i0qUOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HoseLength_3rYdA0qUOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HoseNozzleType_3y6Ee0qUOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ClassOfService_09DTa0qUSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ClassificationAuthority_0GzNs0qUSHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0O78k0qUSHuO00025QrE$V" Name="Pset_FireSuppressionTerminalTypeSprinkler" Description="Device for sprinkling water from a pipe under pressure over an area (BS6100 100 3432)" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcFireSuppressionTerminal/SPRINKLER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SprinklerType_0TUTO0qUSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Activation_0nlTC0qUSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Response_0zgPK0qUSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ActivationTemperature_17ovE0qUSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoverageArea_1DADu0qUSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasDeflector_1J7hy0qUSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BulbLiquidColour_1PhJQ0qUSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DischargeFlowRate_1im0Q0qUSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ResidualFlowingPressure_1o7L40qUSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DischargeCoefficient_1u4p80qUSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumWorkingPressure_1zS7o0qUSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConnectionSize_23Pbs0qUSHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2XGPbxl_jExB7PWxQahLSy" Name="Pset_FittingBend" Description="Properties about the bend angles." ApplicableEntity="IfcCableCarrierFitting/BEND,IfcDuctFitting/BEND,IfcPipeFitting/BEND">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="BendAngle_3jE3I0qV8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BendRadius_3obNy0qV8HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1yk8VooW5BRAdxFkeL0$cz" Name="Pset_FittingJunction" Description="Properties about Fitting Junction." ApplicableEntity="IfcCableFitting/JUNCTION,IfcDuctFitting/JUNCTION,IfcPipeFitting/JUNCTION,IfcCableCarrierFitting/JUNCTION">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="JunctionType_0vWtI0qVCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="JunctionLeftAngle_161yq0qVCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="JunctionLeftRadius_1Ap840qVCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="JunctionRightAngle_1J9Bm0qVCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="JunctionRightRadius_1NwN00qVCHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0XYyGe0L1DWfmed2IV_RiG" Name="Pset_FittingTransition" Description="Properties about Fitting Transition." ApplicableEntity="IfcCableFitting/TRANSITION,IfcDuctFitting/TRANSITION,IfcPipeFitting/TRANSITION,IfcCableCarrierFitting/TRANSITION">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalLength_3OohBqhOr7qe_LKHtDErK8" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EccentricityInY_0sGv0_Fz15KQ5d5v6ZqgOf" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EccentricityInZ_1bzSQEjR99Xf_xfCOD1h$R" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2AZMk0qUSHuO00025QrE$V" Name="Pset_FlowInstrumentPHistory" Description="Properties for history of flow instrument values. HISTORY: Added in IFC4." TemplateType="pset_performancedriven" ApplicableEntity="IfcFlowInstrument">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Value_2GWqo0qUSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Quality_2Khse0qUSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_2Ngbg0qUSHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2RrdW0qUSHuO00025QrE$V" Name="Pset_FlowInstrumentTypeCommon" Description="Flow Instrument type common attributes. HISTORY: Added in IFC4." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcFlowInstrument">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_2caGq0qUSHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2sgEo0qUSHuO00025QrE$V" Name="Pset_FlowInstrumentTypePressureGauge" Description="A device that reads and displays a pressure value at a point or the pressure difference between two points." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcFlowInstrument/PRESSUREGAUGE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="PressureGaugeType_2ydis0qUSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DisplaySize_3AxEc0qUSHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3I4$U0qUSHuO00025QrE$V" Name="Pset_FlowInstrumentTypeThermometer" Description="A device that reads and displays a temperature value at a point." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcFlowInstrument/THERMOMETER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ThermometerType_3NSK80qUSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DisplaySize_3blru0qUSHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3ivcm0qUSHuO00025QrE$V" Name="Pset_FlowMeterOccurrence" Description="Flow meter occurrence common attributes." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcFlowMeter">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="FlowMeterPurpose_3pTEE0qUSHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="01ml_0qUWHuO00025QrE$V" Name="Pset_FlowMeterTypeCommon" Description="Common attributes of a flow meter type" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcFlowMeter">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_0D5Yi0qUWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReadOutType_0R$Ds0qUWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RemoteReading_0gIlc0qUWHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0msN40qUWHuO00025QrE$V" Name="Pset_FlowMeterTypeEnergyMeter" Description="Device that measures, indicates and sometimes records, the energy usage in a system." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcFlowMeter/ENERGYMETER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalCurrent_0sDhk0qUWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumCurrent_0w_s_0qUWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MultipleTarriff_10MBe0qUWHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="17VyW0qUWHuO00025QrE$V" Name="Pset_FlowMeterTypeGasMeter" Description="Device that measures, indicates and sometimes records, the volume of gas that passes through it without interrupting the flow." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcFlowMeter/GASMETER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GasType_1CtHA0qUWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConnectionSize_1SN5k0qUWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumFlowRate_1a7000qUWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumPressureLoss_1euBG0qUWHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1m1y80qUWHuO00025QrE$V" Name="Pset_FlowMeterTypeOilMeter" Description="Device that measures, indicates and sometimes records, the volume of oil that passes through it without interrupting the flow." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcFlowMeter/OILMETER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConnectionSize_1SN5k0qUWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumFlowRate_1xyuG0qUWHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="22WVk0qUWHuO00025QrE$V" Name="Pset_FlowMeterTypeWaterMeter" Description="Device that measures, indicates and sometimes records, the volume of water that passes through it without interrupting the flow." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcFlowMeter/WATERMETER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Type_27tqO0qUWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConnectionSize_1SN5k0qUWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumFlowRate_2PmEa0qUWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumPressureLoss_2Vjie0qUWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BackflowPreventerType_2aUtu0qUWHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2szRU0qUWHuO00025QrE$V" Name="Pset_FootingCommon" Description="Properties common to the definition of all occurrences of IfcFooting." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcFooting">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_2jqPnPi7zFNRX$OEExuOpW" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LoadBearing_13kNCI9h11aBPeqCQFREYC" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2Y45MOd4rHasscEBWnqYhV" Name="Pset_FootingTypePadFooting" Description="Properties of footing. The property set can be used by the predefined type PAD_FOOTING of IfcFooting." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcFooting/PAD_FOOTING">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="LoadBearingCapacity_2RBEe0qSKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsReinforced_1Qp9XSGSD30AXUnzycyqDf" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="344gQ0qUWHuO00025QrE$V" Name="Pset_FurnitureTypeChair" Description="A set of specific properties for furniture type chair. HISTORY: First issued in IFC Release R1.5. Renamed from Pset_Chair" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcFurniture/CHAIR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SeatingHeight_3AeHu0qUWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HighestSeatingHeight_3Gbly0qUWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LowestSeatingHeight_3W5aW0qUWHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3hQNE0qUWHuO00025QrE$V" Name="Pset_FurnitureTypeCommon" Description="Common properties for all types of furniture such as chair, desk, table, and file cabinet. HISTORY: First issued in IFC Release R1.5. Renamed from Pset_FurnitureCommon. IFC 2x4: &apos;IsBuiltIn&apos; property added" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcFurniture">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_1pD6GEhpb3kQoohaFgDAHz" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Style_3tLJM0qUWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalHeight_00HWS0qUaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalLength_0NS18P1J51kRFniH3h5CIL" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalDepth_0HZnE0qUaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MainColour_0Pvqw0qUaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsBuiltIn_0VtI_0qUaHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0ddDG0qUaHuO00025QrE$V" Name="Pset_FurnitureTypeDesk" Description="A set of specific properties for furniture type desk. HISTORY: First issued in IFC Release R1.5. Renamed from Pset_Desk" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcFurniture/DESK">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="WorksurfaceArea_0i_Xw0qUaHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0q8Io0qUaHuO00025QrE$V" Name="Pset_FurnitureTypeFileCabinet" Description="A set of specific properties for furniture type file cabinet HISTORY: First issued in IFC Release R1.5. Renamed from Pset_FileCabinet" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcFurniture/FILECABINET">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="WithLock_0uvU20qUaHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="10fOK0qUaHuO00025QrE$V" Name="Pset_FurnitureTypeTable" Description="HISTORY: First issued in IFC Release R1.5. Renamed from Pset_Table" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcFurniture/TABLE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="WorksurfaceArea_16csO0qUaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfChairs_1B_B20qUaHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2DktIDjlD5MOM71NNmbzym" Name="Pset_GateHeadCommon" Description="Properties common to the definition of all occurrences of _IfcMarinePart_ with the predefined type set to GATEHEAD." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcMarinePart/GATEHEAD">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="StructuralType_0cKUD5vlD8$g5oDvXR_9FO" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3xgKP8ayz7rPLyWDXYnkZ1" Name="Pset_GeoAspects" Description="Description of geological aspects that are relevant for the tunnel design and execution phase." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcTunnelTypicalSection/GEOTECH">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Overburden_0Z9glM65n3EvhYmPteI6Jw" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GroundwaterDesignPressure_2Yt2lRKNn8Nw8eA8RdSylB" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaxGroundwaterInflow_1r_R2cU1zAd9hH_hcBobVb" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GroundwaterAgressiveness_0eilySCHX2FwvuWJBgvmtA" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GroundwaterTemperature_3IMyTWYAj0SuSW8M3JUwRd" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Karst_3P_YQ46mn8svjq87SZAWhd" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Boulders_3bLi1JRx93T88yfLqjfaa3" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GasType_3xONOgIiDFaPnwg2ne4hqt" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GasConcentration_39aIOtx2DEa802QYg_FsGV" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DumpCategory_0YD7LOfxzCLBoIp$XLTV09" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Contamination_2MUPtI9NP8bvLCMAJRde53" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InSituStress_3raVy7oj187xRtL6ooBSHH" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Swelling_1PJ_yR2ovAQwJ7uPoRxZb1" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GroundTemperature_3iQRoUZRb2nOp0QHhQ7OX4" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CloggingPotential_15oxfkdunAHQ0G5Q2ybvfa" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AsbestosPotential_3Kf7Ic90PCrOHQqSF4YAvL" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HeavyMetalsPotential_0SJ24gCS50MRli9TNYKxGx" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2TeqtFqz50WeqGCbpu9MLr" Name="Pset_GeoObsBoreholeCommon" Description="Common properties for borehole logs." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcGeoScienceObservation/BOREHOLELOG">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="DepthRange_0NQ19_ZHX2QfMh8143pjcc" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3hEXFKvYn0LfnYF$GMf6XZ" Name="Pset_GeoObsBoreholeConstruction" Description="Properties for describing the construction of a borehole." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcBorehole">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="DrillingDiameter_32JL8Vw$L9BhN7Dgy0bzPU" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LiningMaterial_0mAA1gW8z7mevSgdceBIp5" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BoreholeFilter_3fE4eMnCT7eveQISamMQlZ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BoreholeInstallation_0o06vNWW901uy$1qJJssW7" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2l2KlrXhj1fP34NQqovFR3" Name="Pset_GeoObsBoreholeGeoLogInterval" Description="Properties for geolog intervals." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcGeoScienceObservation/BOREHOLELOG">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GeologyCode_1haXibmFT39BKx1k_TwkeU" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Weathering_1Sb_Wrxcr569u3CJuzXzLj" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FractureIndex_2g$diqZkvF5QTVAB4_JcMO" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RockQualityDesignation_2OwiKpq$T2WBhXOg_6HYJQ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TotalCoreRecovery_0Q7mU7oh9C1AczkUB_dSwZ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SolidCoreRecovery_00Xk2UDNv8yQeOebTR368_" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2zbApGzEHES9A$1GkkC$pf" Name="Pset_GeoObsBoreholeGeophysicalInterval" Description="Properties for describing geophysical intervals." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcGeoScienceObservation/BOREHOLELOG">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="PwaveVelocity_25QNLFrcX23AOU3hgpu9do" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SwaveVelocity_0Zt9yzVWjF3QUsVuryk8eT" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulus_1HMLggJlb57v8ii$EHduxM" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PoissonRatio_25Cn_0qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DryBulkDensity_0nEw_cmQP96hsnDkHk7anm" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WetBulkDensity_2I9krS8W54Uezs_moDPWYf" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Resistivity_0CD1$azajCjeK721qDipOz" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SpontaneousPotential_0QWHw4BW90SxlAkUg4JefW" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GroundwaterTemperature_3IMyTWYAj0SuSW8M3JUwRd" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HoleDiameter_2CRBoJG6P9xwWyupBQZ76M" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GammaRay_0uQOo2p7L7gfdVTXwVzLwb" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3MTZf4_Gn1rQJxvJyblp7$" Name="Pset_GeoObsBoreholeMWDInterval" Description="Properties for describing MWD (Measure While Drilling) intervals." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcGeoScienceObservation/BOREHOLELOG">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Hardness_0NzH_YWI19COOLq3fLYBdn" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Cracking_3j43tcg$LEXgFS1pHxFkCO" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WaterLeakage_0nA2qw75z08e_duxVyg0IJ" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0nd9pp0mz3xAiA5LACe_hi" Name="Pset_GeoObsBoreholeWaterLevel" Description="Properties for describing water levels in boreholes." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcGeoScienceObservation/BOREHOLELOG">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="WaterLevel_1q98Z7TRf7bP3iVW84ueQW" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsPiezometric_1c5OF998b1_8SQzyRB0_vU" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1fJt9GnVj6P8nB35bSEYey" Name="Pset_GeoObsCommon" Description="Common properties for geoscience observations." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcGeoScienceObservation,IfcBorehole,IfcSensor,IfcSpatialZone/MAPPEDZONE,IfcSpatialZone/TESTEDZONE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ObservationStartDate_0NUJ4QuQPDpehtroDooVHq" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ObservationEndDate_1f3yCK9b927PPJI96ub41r" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Lithology_0LdEScS1D9oRyQIFkXH3yi" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2rk$ivwTfBpOerYFs_H1h9" Name="Pset_GeoObsDiscontinuityCommon" Description="Properties of discontinuities or discontinuity sets in rock according to ISO EN 14689." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcGeoScienceObservation/MAPPEDFEATURE,IfcGeoScienceObservation/LOCALINFORMATION,IfcGeoScienceFeature/DISCRETEDISCONTINUITY">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="DiscontinuityType_1JP9rcjFXARB5hBdhk7ExF" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DipDirection_2ECbWpcBD9gfOatn_dmz2$" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DipAngle_2AwUZOVX992eTuSYTjeerL" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DiscontinuitySpacing_0Ng07cMyPCy9WuDPLjdmv2" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DiscontinuityPersistence_03K4NkMlL77OQrLEIDA6QX" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DiscontinuityRoughness_0Hf64hl09A88FtMA190$UT" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DiscontinuityAperture_1TCPy13C92zPuCOEju$jod" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DiscontinuityInFilling_2bLAkUOk95KPc7a3XyxzcW" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DiscontinuityWaterSeepage_37bDGHt1D5IeRZslC_HS3J" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DiscontinuityCohesion_1f3CPfTDP4_hW9D7kdBT5b" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DiscontinuityFrictionAngle_1QIEUQzzj61QvEZL4KqYmB" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="05jI9UzJrFPPDO5hHKCniW" Name="Pset_GeoObsDiscontinuityFault" Description="Properties for geological fault observations." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcGeoScienceObservation/MAPPEDFEATURE,IfcGeoScienceObservation/LOCALINFORMATION">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="FaultType_2cTF3eVlf2_80LnK_n7O6x" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FaultThickness_3pHrpKqNzD2x2$n3ipmRil" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FaultLength_36HCJE4Fj1vAsieqy08nef" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DeformationPhase_34v8HVl7D5$hjlWFWQDfkK" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FaultSlipDirection_0_Rv9JVL5DTR1ugllbwXU4" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Displacement_2JpsASSV5Cifkpo$1F70wR" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FaultPitchAngle_2amUo6QL91DeGgZLQHgMyf" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2Xf6OXOmb0_QrFtFG466nA" Name="Pset_GeoObsFoldAxis" Description="Properties for geological fold axis observations." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcGeoScienceObservation/MAPPEDFEATURE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="FoldType_1CiTInSyDDw8cLG6539eAN" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DeformationPhase_34v8HVl7D5$hjlWFWQDfkK" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AzimuthHingeLine_39UFUKWgf4gOAXmd1DKyEZ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AzimuthHingeLineation_1bK1xqeB57exCDB4QMcG7Z" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Plunge_0jANEsqIjD28q6omcrafcL" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1fU2t$rhP58PUpnS6FA3q0" Name="Pset_GeoObsHydroGeologyWaterInflow" Description="Properties for hydrogeological water inflow observations." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcGeoScienceObservation/LOCALINFORMATION">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SourceType_1wNA_lF8j57Ati7DZewGaj" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SourceArea_1BMVyQRuL1zRS08BFGzp4P" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InflowRate_1Fbf$7xkPDquOoD4prK2TA" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InflowSum_2OMwvg2WD9yQR5E1WntDRu" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3Dwgj2Yl59NBWNvKGt0fx0" Name="Pset_GeoObsLineation" Description="Properties for geological lineation observations." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcGeoScienceObservation/MAPPEDFEATURE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="LineationType_133IV34718eB2pTloYu4BE" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DefiningElement_2ZmUzi2L1FPfWOuad7mKFO" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DipDirection_17WEfvK3L9Ehv8Rdn5AK_c" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Plunge_0jANEsqIjD28q6omcrafcL" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DeformationPhase_34v8HVl7D5$hjlWFWQDfkK" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3iHbPUImjEp87zneaEn9ID" Name="Pset_GeoObsMappedUnit" Description="Properties for geoscience observations at mapped units." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcGeoScienceObservation/MAPPEDFEATURE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="AreaID_1LX3rTqy19RRHx3VNZyWTI" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoveragePercentage_0zErkL8B54XBTK$nUEKqm5" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Weathering_3VudkS3GP7whCc9fnu5Tf9" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DiscontinuitySpacing_0VQZBIVenAlegXF1tlHC9e" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GSI_0jXoIJ8Fz6WuI01oi0uMuh" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RMR_0P4g7RHODAnPtwhbwtKXgn" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="QValue_2AP24nbKP3hfI8vdx$uG8T" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="12HjOstGD25elrrLtnCIN8" Name="Pset_GeoObsPtObservationCommon" Description="Properties for geo-science observations at points." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcGeoScienceObservation/LOCALINFORMATION">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Weathering_3i$R3pRvTADgYlPxiIMGTo" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Veining_3h06n0RZX828Bq2sM4rpBg" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GroundTemperature_2lSWAaqvfDPgf2dncsUHxG" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Karst_0AcIORqg96AgGOq$7Qdkzh" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Boulders_3OFU_v1XvEGvqbexrHXzdz" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GasType_0i7RYafnT6WPVPIwyUyF1u" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GasConcentration_2PG$JI90zDQPVTLSZVlkZv" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GroundwaterAgressiveness_0mQnX78kz9AByN_68nPESp" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GroundwaterTemperature_3IMyTWYAj0SuSW8M3JUwRd" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1IXfQIR$jEIQR_GcmzsKeu" Name="Pset_GeophysicalSurveyBorehole" Description="Properties for setup of geophysical surveys incorporating boreholes." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcGeoScienceObservation/GEOPHYSICALSURVEYRESULT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="BoreholeGeophysConfiguration_1LBvY6mqnA6Bh1tDfqA$ws" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0cn_oGUnzBIeVBA_qnd7dZ" Name="Pset_GeophysicalSurveyCommon" Description="Common properties for geophysical surveys." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcGeoScienceObservation/GEOPHYSICALSURVEYRESULT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SurveyMethod_0XFkOpEhL5FurL0EyiIIEX" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SurveyInstrumentManufacturer_0rqYHwzg5EY9Q2cWqaXGxR" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SurveyInstrumentModel_3DqMDOkJT9PgLG27L3f5fD" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SurveyDimension_3BKUMNltrF3A3l2i5qFCSe" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1tuYisMEDCn90F4K8YgfgA" Name="Pset_GeoScienceFeatureTypeContact" Description="Defines properties for contacts where a contact is a general concept representing any kind of surface separating two geologic units, including primary boundaries such as depositional contacts, all kinds of unconformities, intrusive contacts, and gradational contacts, as well as faults that separate geologic units." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcGeoScienceFeature/CONTACT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GeoContactType_0cv0MyVAnAzeuvZv_LHADf" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DipDirection_17WEfvK3L9Ehv8Rdn5AK_c" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1ODXL1Ot12y8u_2Cv8z52_" Name="Pset_GeoScienceFeatureTypeDiscontinuity" Description="Properties of discontinuities or discontinuity sets in rock.
&gt;NOTE according to ISO EN 14689" TemplateType="pset_occurrencedriven" ApplicableEntity="IfcGeoScienceFeature/GEOTECHNICALUNIT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="RockQualityDesignation_2o32BT3ZX4bO$w85z$rZ25" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="StrikeDirection_2OgLQou3zDDO0kYsfjEdze" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DipDirection_2ECbWpcBD9gfOatn_dmz2$" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DipAngle_2AwUZOVX992eTuSYTjeerL" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DiscontinuitySpacing_0Ng07cMyPCy9WuDPLjdmv2" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DiscontinuityPersistence_03K4NkMlL77OQrLEIDA6QX" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DiscontinuityAperture_1$QA6RBqr9RARD6tIYf9PS" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DiscontinuityFilling_0oNOrk83X1qOyXWFFmxs63" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DiscontinuityRoughness_0Hf64hl09A88FtMA190$UT" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DiscontinuityWaterPresence_13x1J$ipnCAAAJyT_0MNF4" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Cohesion_0TtDZk$qPAvwTsHe72Iikw" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DiscontinuityFrictionAngle_1QIEUQzzj61QvEZL4KqYmB" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1jAngZQI5A4wdq6ryez7ai" Name="Pset_GeoScienceFeatureTypeFault" Description="Properties for faults." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcGeoScienceFeature/FAULT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="FaultMovementType_1HEf8LNPb5ZAU_EKoyIhJa" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FaultDeformationStyle_1lYGGx_1jCCxEUZce$aPdE" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FaultDisplacement_1SqeJ7wlr3KhX7hE0uIsj3" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FaultGeologicHistory_2VqusjTyz7Rwv4WEaW6XDu" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DipDirection_2ECbWpcBD9gfOatn_dmz2$" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FaultActivity_2JUec9o7r0AvVBR7Pu457g" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FaultLength_3afQABxmjCF9PigO8LJ2xb" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FaultInfilling_2JZfahd4z6yxCGa85SabRQ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FaultSlipDirection_1Bo9zfmPXBcf$1nNl3sOVz" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0fo4MQd5n8ePKp0wpCDTuS" Name="Pset_GeoScienceFeatureTypeFluidBody" Description="Properties for fluid bodies." ApplicableEntity="IfcGeoScienceFeature/FLUIDBODY">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="PHLevel_0$mo80qUuHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="11O9XOF3r8XRAslnrIE7x3" Name="Pset_GeoScienceFeatureTypeFold" Description="Properties for folds." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcGeoScienceFeature/FOLD">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ProfileType_1AEKQiP7PFbuAGZ6obzmNO" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="StrikeDirection_2OgLQou3zDDO0kYsfjEdze" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DipDirection_17WEfvK3L9Ehv8Rdn5AK_c" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1wMwN_GT94zRM5c7BcS_fb" Name="Pset_GeoScienceFeatureTypeGeoHazard" Description="Properties for geo hazards" TemplateType="pset_occurrencedriven" ApplicableEntity="IfcGeoScienceFeature/HAZARDAREA">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="HazardType_0GcxsviM9DV8_rT2wHb7ew" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LikelihoodOfOccurence_2o2ITB5d9B5fr3psKiYy0J" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LevelOfIntensity_2slUGIunH3dByQMgke_Zq_" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ValidityPeriodDescription_3sTydqA0X1juk$nPEo2NdK" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ValidityPeriodEncoding_1vhiHkV1v0Afc8IcJjQGJd" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DeterminationMethod_35EM4seR58qOdMRpSplbuQ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HazardLevel_0PFY59vVb2TvMgPikQVr$X" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2DerJxvgn5p8e6wPJoqkcA" Name="Pset_GeoScienceFeatureTypeGeologicalUnit" Description="Properties for geological units." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcGeoScienceFeature/GEOLOGICALUNIT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GeologicUnitType_3kvkEL4rr7TelKN6g8aSiF" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Rank_2nKOcVn1PD5Arvkf8nGOWd" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Lithology_3Ib9wYZlH8rvMKekRGTYia" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GeologicHistory_1iHvbtNqf6U9Bzcl_08dUS" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RepresentativeAge_0IUFUUDNnBTfdUGKBAJimE" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FaciesLithostratigraphy_2XLky_iMD0vQgzsjnsjpw7" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FaciesPetrophysics_2Jx2bqqWv50AEBqzbKQZTD" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GeologicalHazard_3j7ItBCun2pf_7JPhtV8eb" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0EEgcj$2TEXwZZRNoUDh$E" Name="Pset_GeoScienceFeatureTypeHydroGeoUnit" Description="Properties for hydrogeo units." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcGeoScienceFeature/HYDROGEOUNIT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="UnitRecharge_0CjjY8gGfAcQfADgdDjQOz" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UnitDischarge_2j9UjMlrj7DQqFFjx5YGf1" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HydraulicPermeabilityHorizontal_0cGG3NyxfEXf7guGaaxUkx" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HydraulicPermeabilityVertical_1aKYiWegb7iPXpy4cjfbOY" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Transmissivity_2iOpQUtFb9RODz2KOn3Z6g" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="StorageCoefficient_36wybY1$X62RvbVDalUFnE" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1x6JuYXOD0owhT093yTTek" Name="Pset_GeoScienceFeatureTypeIntactRock" Description="Properties for intact rock." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcGeoScienceFeature/GEOTECHNICALUNIT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Lithology_3Ib9wYZlH8rvMKekRGTYia" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GeologicalFormation_2bpjqV7bf5FRh$hybIccDv" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UnconfinedCompressiveStrength_3y02KcJ79CL80neBRiH8Lp" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulus_1HMLggJlb57v8ii$EHduxM" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PoissonRatio_25Cn_0qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TensileStrength_1rOUUKaLX2jg4ES1N0oyri" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MineralComposition_0_NdsEekX2ZBhbUfaRHNgY" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VoidRatio_3iyX_eZCr9MgXBX7IpP$HN" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Weathering_0e5dTwbh19SRXa21Al10uH" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1q95ux_dz7o9GCftMsxmwj" Name="Pset_GeoScienceFeatureTypePiezometricWaterLevel" Description="Properties for piezometric water levels." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcGeoScienceFeature/PIEZOMETRICWATERLEVEL">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Elevation_2IUsNzp9b5HxiNZd7EdtMT" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3H0MlShVPD3wZI1Az$eApM" Name="Pset_GeoScienceFeatureTypeRockMass" Description="Properties for rock mass." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcGeoScienceFeature/GEOTECHNICALUNIT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="RockQualityDesignation_2o32BT3ZX4bO$w85z$rZ25" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RockMassRating_2qdGAN$0PBMO5OKXlwlUlX" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="QValue_1bhEISWbXCwxu8IMpl$sWn" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GeologicalStrengthIndex_1mKh3XC4vAkAZD1jzmwtzK" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulus_1HMLggJlb57v8ii$EHduxM" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Cohesion_0TtDZk$qPAvwTsHe72Iikw" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FrictionAngle_3D7neWa7f4ih$KjXeaqaqO" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="K0_3LHWuSc4f4oAmYOduGjUmW" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1aTTnkN4z39gyMNXctShot" Name="Pset_GeoScienceFeatureTypeSoilLikeMaterial" Description="Properties for soil like material." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcGeoScienceFeature/GEOTECHNICALUNIT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Lithology_3Ib9wYZlH8rvMKekRGTYia" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WaterContent_2wZL3Anx93bBPkmx7Acxjd" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VoidRatio_3iyX_eZCr9MgXBX7IpP$HN" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WetBulkDensity_2I9krS8W54Uezs_moDPWYf" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DryBulkDensity_0nEw_cmQP96hsnDkHk7anm" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulus_1HMLggJlb57v8ii$EHduxM" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MenardLimitPressure_1CWkbvhoTDa9YkTFzoriqt" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CPTconeResistance_0tVj04fSz9yvcArAhgc6n1" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SPTBlowCount_35XQNkKeH4W8XkaRfglEJO" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PlasticityIndex_2LRVKFYkv7MBBC_EdSek5O" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConsistencyIndex_2o9pe5Y8DEiR3DEK$WihGW" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PeakCohesion_1TVc0spc13oOyuIwsuBSiU" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ResidualCohesion_21T5RytGz4yvSfcQD$D7p2" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PeakFrictionAngle_0z1h4Y4EvBmefF2zOURpEQ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ResidualFrictionAngle_3VU660bRHEbQc1t926BAZb" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UndrainedShearStrength_0n38wMri16s8QxCTdB1sg_" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PoissonRatio_25Cn_0qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CompressionIndex_1kCf5Yyzb0mg8elIJgHtFu" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SwellingIndex_2gc$MqEfT7o9RCMSQRED$B" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OCR_3J8URKaDb0hfGVNxhjZK2p" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="K0_19WbY_VgHBFw4Tv8TsWyiH" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RelativeDensity_3SB3FKZuL3KRYmDmfBsQvb" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2J5BDOyLrFkBAXO$VeAIP6" Name="Pset_GeoScienceModelCommon" Description="Common properties for geoscience models." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcGeoScienceModel">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ModelUseCase_0VofZ3$$j5mvopc7We4Ym7" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CreationDate_3CaOJkVC194viZ6LJTu7ed" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReleaseDate_18Baepiu9DMu1YZ7vyV2Zi" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UpdateDate_3JKy7u4y16EgxfwwY7RYg8" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VersionNumber_05P2$JUujC9AsIOpln0NTr" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ModelPurpose_1gm$OqDpv9KQq3uIG1DEsc" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ModelStatus_16vVl01en6dv09d8hlKChk" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Authors_1oQcJRV0j0WhD1ng6TcHzF" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Organizations_0Ksewl9eXCOBb5HfyICi72" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AreaOfInterest_1KWCYITgX9jOp69TrRoKW5" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2ZhPnm3EjETBVFHvuClwRt" Name="Pset_GeoSciencePropertiesCommon" Description="Properties common for geological and geotechnical units." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcGeoScienceFeature/GEOLOGICALUNIT,IfcGeoScienceFeature/GEOTECHNICALUNIT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="PwaveVelocity_3PNsA2fgH81Aaey7kS$TDO" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SwaveVelocity_1LvJ8TerD4XunolAqoyu8J" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Resistivity_0CD1$azajCjeK721qDipOz" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WetBulkDensity_0zymFCuR5CTx4wkxmFWmPt" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GroundwaterTemperature_3IMyTWYAj0SuSW8M3JUwRd" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DryBulkDensity_2Zd$lo7FL9eP39_zTeDr$R" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="22bpHpV7n79RGrMAIe0WWU" Name="Pset_GeotechnicalAssemblyCommon" Description="Properties describing the characteristics of any geotechnical model. A Status of &quot;New&quot; should not be associated to a _IfcGeotechnicalAssembly_ or _IfcGeotechnicalStratum_, as other entities are used for earthworks and courses." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcGeotechnicalAssembly">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Limitations_0wl2LrL0b7mR5ua2A1tgcx" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Methodology_2rVw3QGqHCNhBarO$sArmh" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BoreHolePurpose_0B_BoCWVj11vkE_OgYOaPd" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_11wQ4bRUr9fho1muno$GPl" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0JwLqHW2rDdfZ9ytdM49Bf" Name="Pset_GeotechnicalStratumCommon" Description="Properties describing the characteristics of any solid, water or void stratum. A status of &quot;New&quot; should not be associated to a _IfcGeotechnicalAssembly_  or _IfcSolidStratum_, as other entities are used for earthworks and courses." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcGeotechnicalStratum">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="StratumColour_0iHTZHO0b8BO33foHizEN0" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsTopographic_2E3ZmSESz08wrQaLoH1SHI" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PiezometricHead_24tPtOUmb38eSfLUcU_ipU" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PiezometricPressure_3OfY_ZvlDCMeYOU3FtSlL2" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_11wQ4bRUr9fho1muno$GPl" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Texture_3y575Chyb3lBXIjLdtKF9h" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1kbno7eZf3BPswGzpSBgsS" Name="Pset_GroundReinforcementElementTypeBar" Description="Properties for ground reinforcement elements of type BAR." ApplicableEntity="IfcGroundReinforcementElement/BAR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalDiameter_2QF5fCdFb1LPrQzIOCX_RZ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BarSectionType_36JQMyGJDC7xRwd_60klq0" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UserDefinedBarSectionType_2THcLIk5195hSLwiZLCKs_" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsGrouted_3uTqQIVjvEjAXvCwtg5l_m" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsSelfDrilling_3WwKwa3Qj80x3m3RM3jYw9" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalLength_07RHK0qUaHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="26KPlFUI1AgvmS$k4YqM_g" Name="Pset_GroundReinforcementElementTypePile" Description="Properties for ground reinforcement elements of type PILE." ApplicableEntity="IfcGroundReinforcementElement/.PILE.">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="DistanceFromSurface_1GJthyvlP7KOg_1iksj$Vx" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LengthGroutBody_1l1T$n9HP2kxZocCToc2NI" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LengthEmbedmentInRock_1BHl2y49PD_ggO8$9sd9df" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GroutBodyDiameter_2PVUuyOXLDSgXbqEVZOPKv" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0St17jsIn7veyS$9JNr4CE" Name="Pset_GroundReinforcementElementTypePlate" Description="Properties for ground reinforcement elements of type PLATE." ApplicableEntity="IfcGroundReinforcementElement/PLATE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalLength_07RHK0qUaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalWidth_1iz8qzCsvEiApVczzesmrW" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalThickness_2QgJLpWOb3xfvwr_YO$T_k" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1WyjOOZzP8neYHCDlUxqgP" Name="Pset_GroundReinforcementElementTypeTendon" Description="Properties for _IfcGroundReinforcementElement_ of type TENDON." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcGroundReinforcementElement/TENDON">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalDiameter_30E560qVCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CrossSectionArea_2C5h6JkUbAiuupCKgQxX5Z" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SheathDiameter_3oEHCHEBvA8PGa16tDeoQ3" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TensionForce_3lnzOYG$X5VBKKmCOmDCiI" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PreStress_1AeV_jgFf4lQ6cpFxp6xKo" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FrictionCoefficient_1FHgJZeI9AQvoFPcY4HmIA" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AnchorageSlip_2UgD9v46jEhRDjnavSNqzR" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FreeAnchorLength_0S210oTSH9qA4UjE0XGK_m" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FixedAnchorLength_3yEW81NlTADupBiIcyXmEa" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0oEXOWHtb1aPlSJ1yczWts" Name="Pset_GroundReinforcementElementTypeTube" Description="Properties for ground reinforcement elements of type TUBE." ApplicableEntity="IfcGroundReinforcementElement/.TUBE.">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="OuterDiameter_1D65QTyIPFEwphBQILyT$Q" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TubeThickness_2$asiH00f8LgpWKouTPJnb" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalLength_07RHK0qUaHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2YM1_O9ub3QvmOfh_SHhAK" Name="Pset_GroundReinforcmentElementTypeBolt" Description="Properties for _IfcGroundReinforcementElement_ of type BOLT." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcGroundReinforcementElement/BOLT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="BoltCrossSection_1CDdPMxFj0bw0JOlDAhTgq" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UserDefinedBoltCrossSection_3PBwEzgljAuh8A3E6FbVJY" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BoltType_0uYUldgMH5mRcvZ37CI2wI" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UserDefinedBoltType_0cO6caU4DF3fMAqIlI6j4X" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BoltDiameter_2CtNv1HnL2lBA_fBoeeXLD" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BoltLength_1H5Z$T2YX1fu0c7_lXRSF8" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GroutingType_2gToDgdT90Pvu0v1XANdjJ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UserDefinedGroutingType_3xklYq_Gr9_8Vj6GCEyJXC" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PlateType_1k0KQdYJT4WhtMu_7lyRTR" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HoleDiameter_2GN$WQ6b1BpetO1RE7phA4" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HoleLength_29Zk0kSL57MQM5XAzKvCEW" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LongitudinalInclination_3Z$M_GmZb1svkg1noG1s2m" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RadialInclination_27paS9aKT8DPqJm_ip39qg" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MechanicalTension_0NjLrbe5v3zuECrs8qsUAO" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LockingForce_0pLtPGaujDkwK16bnNbYZE" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CorrosionTreatment_3tiPdiQHXE1RcerDmwYVRN" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Deformability_1tVYnZVTn9oBtykLWbZYCL" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MassPerLength_1bxC00qVOHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1J7xw0qUaHuO00025QrE$V" Name="Pset_HeatExchangerTypeCommon" Description="Heat exchanger type common attributes." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcHeatExchanger">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_1V2u20qUaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FlowArrangement_1mxIE0qUaHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="23$$E0qUaHuO00025QrE$V" Name="Pset_HeatExchangerTypePlate" Description="Plate heat exchanger type common attributes." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcHeatExchanger/PLATE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfPlates_2AZci0qUaHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2HjNa0qUaHuO00025QrE$V" Name="Pset_HumidifierPHistory" Description="Humidifier performance history attributes.
Sound attribute deleted in IFC2x2 Pset Addendum: Use IfcSoundProperties instead." TemplateType="pset_performancedriven" ApplicableEntity="IfcHumidifier">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="AtmosphericPressure_2OG$20qUaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SaturationEfficiency_2dmpc0qUaHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2j88G0qUaHuO00025QrE$V" Name="Pset_HumidifierTypeCommon" Description="Humidifier type common attributes.
WaterProperties attribute renamed to WaterRequirement and unit type modified in IFC2x2 Pset Addendum." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcHumidifier">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_2v34O0qUaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HumidifierApplication_3AxUa0qUaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Weight_3MsQi0qUaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalMoistureGain_3SDlM0qUaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalAirFlowRate_3Xb400qUaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InternalControl_3fK_I0qUaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WaterRequirement_3y$qi0qUaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SaturationEfficiencyCurve_02zIm0qUeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AirPressureDropCurve_0Hszw0qUeHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3Fdb6M3QHB7wXcYvNzANHu" Name="Pset_ImpactProtectionDeviceOccurrenceBumper" Description="Properties common to all occurrences of _IfcImpactProtectionDevice_ with PredefinedType set to _BUMPER_." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcImpactProtectionDevice/BUMPER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="BrakingLength_3S5C4lkGf3_vevKH2HI3L4" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsRemovableBumper_3R8M736eTFRgejCUNrQPuL" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BumperOrientation_3AhGD6LjPDHuOpWNcMtyWq" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1pTuWiKuHoREkmLUeqg3K4" Name="Pset_ImpactProtectionDeviceTypeBumper" Description="Properties common to all occurrences and types of _IfcImpactProtectionDevice_ with PredefinedType set to _BUMPER_." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcImpactProtectionDevice/BUMPER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsAbsorbingEnergy_3kE48CR$D6Sg0O8bEZ6wBy" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumLoadRetention_2cc4B89$DEvPshrGjbP3Kg" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EnergyAbsorption_3cEXeuXEPEEBpQYb23aZbV" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2X3E0Wij1A3ud6V5CYJdPT" Name="Pset_ImprovedGroundCommon" Description="Common properties for improved ground." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcImprovedGround">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="TreatmentHoleCount_3XN76C94L2pvK6fvVtToP7" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AvgTreatmentDepth_2ATszB7MD5rOdgrmtnn2wi" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AvgTreatmentSpacing_3IwKbHD4H2mxQff$jGfKO3" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AvgDepthToTreatment_0k1nV7tkL5ZBpjOwXLSwpl" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AvgTreatmentThickness_2FJiKS$wbFmwMZU50OhXL8" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0g5459gHH0LAJczdfrmeQV" Name="Pset_ImprovedGroundTypeDewatered" Description="Properties describing improved ground of type dewatered." ApplicableEntity="IfcImprovedGround/(.DEWATERED.)">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="DewateringMethod_2oFu7BguH14vxA2DX0JNDX" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="StaticSuctionLift_1nUwk$OBT5O9pgD19FbFDm" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="StaticDischargeHead_0BrAnLHer7kPgv2nOUi7ob" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VolumetricFlowRate_1Zd01dwqHEsBdHToHy7np2" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BoreholeCount_1DBeislK1CbfTPnPGztE29" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AverageBoreholeDepth_3NM6PipTTFyvqSdj8magOF" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BoreholeSpacing_3zHZ8zixv0VPAwab6YkHPN" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1fzYUfCCj2gB3rag0bchdu" Name="Pset_ImprovedGroundTypeInjectionGrouted" Description="Properties describing improved ground of type injection grouted." ApplicableEntity="IfcImprovedGround/INJECTIONGROUTED">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="InjectionPhase_0fT68GhTX6Ou_9wM45hYLt" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InjectionDistributionEquipment_2lnxV9oFn01AvbA6wexzaD" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InsertedDeviceDiameter_3V8MuRReb9K8uXog2uN4dH" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ManchetteSpacing_2kV4pAMCT6lgzNH8KhgyOL" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TAMTubesSpacing_3crl3aiib4G91_PCrBXmy0" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InjectionPackerType_3Nc5dkhQPFdAnZR5V5geX1" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DrillholeCount_2$SNxqBr14fPN2tHxaHFdx" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DrillholeDiameter_0AYonBcML4YQQy0$dhvZUY" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DrillholeLength_1WLtByELb10O_UIdeHHVGD" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DrillholeAngle_2Iz1Ug0hH19wbi$s8Csly$" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DrillholeDrifting_3$L$5j26j91P1kQ1lWGvER" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LongitudinalOverlap_28woezad9CpfySfEKH2kbf" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RadialSpacing_1TqgA7dOj47v0491hg3bm9" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="StopCriteria_0VnR5KKK1AMxLKKTmKRldq" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WorkflowProcess_2P1FpkQRT6cR$TKisPYw_h" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InjectionPressure_29eahe7Wr9cw6L65Rn8pJw" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AsBuiltInjectionDuration_1v8RCK9RDAFeJdKmW$Cunu" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0LNLsTeUn0WghFnx7TWbby" Name="Pset_ImprovedGroundTypeJetGrouted" Description="Properties for improved ground of type JETGROUTED. (Applicability must be amended when PR with PDT JETGROUTED has been merged.)" ApplicableEntity="IfcImprovedGround/JETGROUTED">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="DistanceFromSurface_2hh_Lii_P9XeiCvb$5SjCM" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GroutBodyLength_35IXCwXjn6DBMNwtA1JvqK" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LengthEmbedmentInRock_0KVr_JgdTCmvMy0tfADhco" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GroutBodyDiameter_25qec0hKPDaBiR1Qtt66DX" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="JetGroutingMethod_1vOlBmVz9DAfg$mBl_DOiT" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GroundPressure_1jBfqbXjz0bBfljBTynV2j" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VolumetricFlowRate_1Zd01dwqHEsBdHToHy7np2" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RotationalSpeed_1XFhDz$Wr6ghIQ9AIkzOVX" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AirPressure_0UInmj_h50IAIwdsP3KsR_" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WaterPressure_2kPNEvWOXCOx0LkHjz9Xi$" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2pT$zsyIfBouD5CeYuy0DT" Name="Pset_InSituTestCommon" Description="Properties in common for in-situ tests in soil or rock." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcGeoScienceObservation/INSITUTESTRESULT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="DepthRange_2ZH4HxFCT21QZcxH5WymAo" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TestMethod_2o1_k$NgPFVvqCCR6GOF$0" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TestType_0bwKXZ2_vEmREG23P2KV6g" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2sYZ1vUBj5Dfu7Z6HQ$97h" Name="Pset_InSituTestCPT" Description="Properties for the results of Cone Penetration Tests/Cone Penetrometer Tests (CPTs)." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcGeoScienceObservation/INSITUTESTRESULT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="CPTConeResistance_0mLMG$dEL1XA62swey6_yV" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CPTLocalSideFriction_1lKAeE0kv6OwRjMM25q3Nx" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CPTPorePressure_3oZqP_gfTF5Bo3txSCd61R" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulus_1HMLggJlb57v8ii$EHduxM" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="21wpHUukvEQQK0rzbdZTEs" Name="Pset_InSituTestHydro" Description="Properties for the results of in-situ pumping tests in soil or rock." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcGeoScienceObservation/INSITUTESTRESULT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="HydraulicPermeability_3iagtDsw9DTgUKGeH1bJil" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HydraulicConductivity_0n5hy7wA9CGeRruzAkgVAG" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Transmissivity_2iOpQUtFb9RODz2KOn3Z6g" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Storativity_3r4XeQVXvA6AD_i9IARgJN" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LugeonValue_1Vq$ixlprFEfLHBz9MYvS3" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0kI8aiOr18DQFo$8vaw8ex" Name="Pset_InstallationOccurrence" Description="Properties defining installation information for occurrences of element, asset or system." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcElement,IfcAsset,IfcSystem">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="InstallationDate_2k4h6AVrL8EBlzWRArJDjn" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AcceptanceDate_12dHQ2H3D5Vw6e1UM1sbnF" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PutIntoOperationDate_03cT7VFl92dw8n1GPuqXSv" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0axgw0qUeHuO00025QrE$V" Name="Pset_InterceptorTypeCommon" Description="Common properties for interceptors." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcInterceptor">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_0o2vs0qUeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalBodyLength_12l1E0qUeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalBodyWidth_1AUxW0qUeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalBodyDepth_1IEro0qUeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InletConnectionSize_1P_m40qUeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OutletConnectionSize_1YKpm0qUeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoverLength_1fUae0qUeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoverWidth_1nqeK0qUeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VentilatingPipeSize_1u_PC0qUeHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3FGG$OWNn9fgEWGPQ7R_hk" Name="Pset_IpNetworkEquipmentPHistory" Description="Properties defining performance information for IP network equipment." TemplateType="pset_performancedriven" ApplicableEntity="IfcCommunicationsAppliance/IPNETWORKEQUIPMENT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfPackets_3vGY$gzS1FU9Y3FCcw54as" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2g8JhMcsr7V8yjLSfvPQw4" Name="Pset_JettyCommon" Description="Properties common to the definition of all occurrences of _IfcMarineFacility_ with the predefined type set to JETTY." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcMarineFacility/JETTY">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="StructuralType_0cKUD5vlD8$g5oDvXR_9FO" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BentSpacing_3luyrgW5f2MfRaz4L28ggQ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PierSectionType_3FaWM7fvLCiBp0lVYAk03V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Elevation_2CNMMPOkjA69oPOt9bGTaw" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2dpmU7V6f4LQU8UwYJuxB$" Name="Pset_JettyDesignCriteria" Description="Properties common to the definition of design criteria of all occurrences of _IfcMarineFacility_ with the predefined type set to JETTY." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcMarineFacility/JETTY">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="HighWaterLevel_0S3mSsoqT9xvSAc$Cv67oe" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LowWaterLevel_2CX_WFHkv9vByq2fOmXUgW" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ExtremeHighWaterLevel_3GFn0Pp5r0eQGPHYahYbQS" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ExtremeLowWaterLevel_2BQGedM913bgYQyPz49FRV" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShipLoading_1QIfuyRDnEaQu6kbYym8p3" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WaveLoading_3ixoBF$s5EUxf3ONHSALX6" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FlowLoading_1N4dPw9IT6AvWCtPogKQA_" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UniformlyDistributedLoad_2oFKKjPUb4bA5i8GWGN0uJ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EquipmentLoading_1e0Ns0$oTF1RHtc3O5zTbg" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="21wcI0qUeHuO00025QrE$V" Name="Pset_JunctionBoxTypeCommon" Description="A junction box is an enclosure within which cables are connected.

History: New in IFC4" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcJunctionBox">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_2DrYQ0qUeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfGangs_2TxWO0qUeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ClearDepth_2ZIr20qUeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShapeType_2kddm0qUeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PlacingType_2_jbk0qUeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="JunctionBoxMountingType_3EpZi0qUeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsExternal_3VVh40qUeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IP_Code_3c3IY0qUeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalLength_07RHK0qUaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalWidth_2YZfyYRY1Aa9bsWGvZEaNq" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalHeight_1Fy4XYaJXDTBDDb9f06ofi" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1FaU96ogFCb731BC1xOjdE" Name="Pset_JunctionBoxTypeData" Description="The property set can be used by the predefined type DATA of IfcJunctionBox." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcJunctionBox/DATA">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="DataConnectionType_2cODWDnK9A9RCBk2DE0YiP" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0CRTLokRH2J9JcHKqarM_t" Name="Pset_KerbCommon" Description="Properties for a kerb." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcKerb">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="CombinedKerbGutter_2XVviYqS9BKeFimfQfNm7U" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Upstand_3VCJVzwh9CCfDp_58_XB7_" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Mountable_0nASgQh6r2huzTgAp_avpJ" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1leKE_dk557vIttvjUYIFZ" Name="Pset_KerbStone" Description="Properties for kerb stones." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcKerb">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalHeight_1Fy4XYaJXDTBDDb9f06ofi" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalLength_07RHK0qUaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="StoneFinishes_0D2MZl1bLBAhq4V$nrIFaO" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TypeDesignation_3_nUqKqXv3xheIJewmELBG" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalWidth_2YZfyYRY1Aa9bsWGvZEaNq" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1zxo_xS39E6vE53DrBYEus" Name="Pset_LabTestCommon" Description="Properties describing the laboratory test used to obtain the associated results." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcGeoScienceObservation/LABTESTRESULT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="TestMethod_3AtmxC_ubC0PKlPID5SFFu" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TestStandard_1dl93$6LnCXAW8eMV0BT07" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TestType_0R_wrpT5H45vAClA39wdC1" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3u1GUH9XPAdBXtmbYH1Dm4" Name="Pset_LabTestResult" Description="Properties resulting from commonly conducted laboratory tests on soil, rock or fluid specimens." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcGeoScienceObservation/LABTESTRESULT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="TestedMaterial_1mdH_msufC_uxo9bDOdV6V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UnconfinedCompressiveStrength_2ZCp5dntj43BvWF_dlBh7I" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulus_1HMLggJlb57v8ii$EHduxM" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MassDensity_3TjUq0qUmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WaterContent_1xZFTftuz7KOGWUAYf0RKn" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Porosity_2iu_CiIPj8UepXPOfjNQfw" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CohesionBehaviour_1Ts3cC4K527A$xCe0PeqiV" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FrictionAngle_1sDVHNRT5F8O5O9TVdOgO5" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LiquidLimits_2AHK69qTTB1htxysz9ebsl" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PlasticLimit_2QRKg6a61Ft9rL$4_1Q7GD" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PlasticityIndex_0$zff_imHDMetkQE35AOmz" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Slaking_1GTIyqmf9Eu8cGgYc0$TFp" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HydraulicConductivity_19kpZnztn1VQFucvmNUC96" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3lbf20qUeHuO00025QrE$V" Name="Pset_LampTypeCommon" Description="A lamp is a component within a light fixture that is designed to emit light. 

History: Name changed from Pset_LampEmitterTypeCommon in IFC 2x3." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcLamp">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_3zvAo0qUeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ContributedLuminousFlux_0Fna_0qUiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LightEmitterNominalPower_0Ll320qUiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LampMaintenanceFactor_0SIgW0qUiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LampBallastType_0YsH_0qUiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LampCompensationType_0oyFy0qUiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ColourAppearance_11rx60qUiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Spectrum_1BOHc0qUiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ColourTemperature_1PhpM0qUiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ColourRenderingIndex_1VfHQ0qUiHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1cp2I0qUiHuO00025QrE$V" Name="Pset_LandRegistration" Description="Specifies the identity of land within a statutory registration system. NOTE: The property LandTitleID is to be used in preference to deprecated attribute LandTitleNumber in IfcSite." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcSite">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="LandID_1iAMy0qUiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsPermanentID_1pwHE0qUiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LandTitleID_1x4260qUiHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0c2nGv105Ao8WCAJjWwrH5" Name="Pset_LateralExcavationCommon" Description="Common properties for lateral excavation elements." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcRadialExcavation">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="RadialExcavationType_36CrYf_abBQQiXtlkMLup4" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RadialExcavationTypeOther_3RsgMwbTP2khfQXrle7GMJ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RadialExcavationDirection_0PWybQDsb7VuLXarptQq0N" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RadialExcavationDepth_1hc8WY5vP3gg1foxh3ure3" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="28BH20qUiHuO00025QrE$V" Name="Pset_LightFixtureTypeCommon" Description="Common data for light fixtures.
History: IFC4 - Article number and manufacturer specific information deleted. Use Pset_ManufacturerTypeInformation. ArticleNumber instead.   Load properties moved from Pset_LightFixtureTypeThermal (deleted)." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcLightFixture">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_2LIV_0qUiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfSources_2aoKY0qUiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TotalWattage_2g9fC0qUiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LightFixtureMountingType_2lWzs0qUiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LightFixturePlacingType_35aPu0qUiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaintenanceFactor_3O2zU0qUiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumPlenumSensibleLoad_3U0RY0qUiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumSpaceSensibleLoad_3bACQ0qUiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SensibleLoadToRadiant_3gXX40qUiHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3n58Y0qUiHuO00025QrE$V" Name="Pset_LightFixtureTypeSecurityLighting" Description="Properties that characterize security lighting." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcLightFixture/SECURITYLIGHTING">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SecurityLightingType_3rsJo0qUiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FixtureHeight_05M8M0qUmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SelfTestFunction_0D62e0qUmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BackupSupplySystem_0QDHa0qUmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PictogramEscapeDirection_0eWpK0qUmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Addressablility_0re2G0qUmHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2asvNF1gz5OerpkzPVlCZQ" Name="Pset_LinearReferencingMethod" Description="Describes the manner in which measurements are made along (and optionally offset from) a linear element.

&gt; NOTE&amp;nbsp; Definition according to ISO 19148:2021" TemplateType="pset_occurrencedriven" ApplicableEntity="IfcAlignment,IfcReferent">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="LRMName_0s7OWAZj9Dahx00TGDv8Mp" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LRMType_3gFkmWZM9F69385xEVB7Qv" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UserDefinedLRMType_3OPNP$6b9E0foQwDeAwOED" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LRMUnit_3hWrEPG6TBow7MJYMO7xCA" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LRMConstraint_2xXz1khr17N8VXs3Y3yIkv" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3tyKpdhznDJv5QS8FpmPgL" Name="Pset_MaintenanceStrategy" Description="Property set for the association of a maintenance strategy to an element, asset of system." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcElement,IfcAsset,IfcSystem">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="AssetCriticality_3gS4Hpk8L3vgoq4ExCulT5" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AssetFrailty_00miw_eHPA8P5HEVj_170C" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AssetPriority_2a$iGZQAL2IB_7weB7s430" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MonitoringType_2QzF5YF2H02gNIuBB2WyHW" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AccidentResponse_1CQaLudWX1ogX8LOMOUW_1" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2CbWTFpD17yOCpmWi623ps" Name="Pset_MaintenanceTriggerCondition" Description="Trigger levels for an asset that has an inspection-based maintenance strategy" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcElement,IfcAsset,IfcSystem">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConditionTargetPerformance_2iDip8GTT8zRWOR2gRk8Qk" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConditionMaintenanceLevel_0VfTbc1grAZhnktO2lISqM" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConditionReplacementLevel_18kxxoTgD8MAVYfHV0plY$" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConditionDisposalLevel_1gLmRZ_wH63g1ueUzbq2sS" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="04MMcZBJLFqhmlBdKFCUWk" Name="Pset_MaintenanceTriggerDuration" Description="Trigger levels for an asset that has an PPM based maintenance strategy." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcElement,IfcAsset,IfcSystem">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="DurationTargetPerformance_2Y0uegcZf7RAvwBrRwhGyj" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DurationMaintenanceLevel_1gQdA$yNX0POemNRUyqM7I" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DurationReplacementLevel_3RZbfgMY10_e7CpEeGzIIB" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DurationDisposalLevel_16JK8wyPLDO8Mk8M9dZ9GE" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0x9FOmebv05QzdAHTrpfVJ" Name="Pset_MaintenanceTriggerPerformance" Description="Properties for performance based maintenance policies" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcElement,IfcAsset,IfcSystem">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="TargetPerformance_3YBpMKO1H0zhLW9cAjhxfY" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PerformanceMaintenanceLevel_1iqiV1Bdv9kP1zFmTnxXvA" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReplacementLevel_0zVRGQx$r18AMXYOzl_qyE" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DisposalLevel_2uwAVU8$D7Mfn2xkuHNa0V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="16wJ20qUmHuO00025QrE$V" Name="Pset_ManufacturerOccurrence" Description="Defines properties of individual instances of manufactured products that may be given by the manufacturer.
HISTORY: IFC 2x4: AssemblyPlace property added. This property does not need to be asserted if Pset_ManufacturerTypeInformation is allocated to the type and the AssemblyPlace property is asserted there." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcElement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="AcquisitionDate_1BhUI0qUmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BarCode_1H2oy0qUmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SerialNumber_1MQ7c0qUmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BatchReference_1SNbg0qUmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AssemblyPlace_1YL3k0qUmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ManufacturingDate_1$Jp6hK45Bou8c2TZpfomg" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1nquI0qUmHuO00025QrE$V" Name="Pset_ManufacturerTypeInformation" Description="Defines characteristics of types (ranges) of manufactured products that may be given by the manufacturer. Note that the term &apos;manufactured&apos; may also be used to refer to products that are supplied and identified by the supplier or that are assembled off site by a third party provider.
HISTORY: This property set replaces the entity IfcManufacturerInformation from previous IFC releases. IFC 2x4: AssemblyPlace property added." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcElement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GlobalTradeItemNumber_1u_fA0qUmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ArticleNumber_1_Lzq0qUmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ModelReference_24vbI0qUmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ModelLabel_2C3MA0qUmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Manufacturer_2Icze0qUmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ProductionYear_2OaRi0qUmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AssemblyPlace_2V83A0qUmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OperationalDocument_0IY8b_L9X4sA7TO47jzP3_" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SafetyDocument_0oiMmeRHTAL8wF_F2pVv8T" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PerformanceCertificate_3Hl5J4f$HClxP3X9VzH3yF" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="07WFKSLAz91POvzmgH52U$" Name="Pset_MarineFacilityTransportation" Description="Properties common to the definition of all occurrences of _IfcMarineFacility_ which are catagorised as transportation facilities such as Ports, marinas etc." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcMarineFacility">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Berths_2x4Y1IYYv4$h9BLcWB9gLQ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BerthGrade_1784IOUnfDrOCPB7_1W7Jl" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BerthCargoWeight_3mukLKUYvFDBZX5V9O8L21" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1ZgGUne6L6zQs_6wmcth95" Name="Pset_MarinePartChamberCommon" Description="Properties common to the definition of all occurrences of _IfcMarinePart_ with the predefined type set to CHAMBER." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcMarinePart/CHAMBER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="EffectiveChamberSize_0Pt2rrz9f1d9B7W_YtzB4B" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="StructuralType_0cKUD5vlD8$g5oDvXR_9FO" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3$u2dLa1v2cwkt_ROQVFKh" Name="Pset_MarineVehicleCommon" Description="Properties common to the definition of all occurrences of _IfcTransportElement_ and types of _IfcTransportElementType_ with the predefined type set to VEHICLEMARINE." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcVehicle/VEHICLEMARINE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="LengthBetweenPerpendiculars_049V7LE0rEtgYKr9j$$ZjS" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VesselDepth_1XDZu1a5f32R9ecKDd56ze" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VesselDraft_1$K81vvzf2buienp$q3rxV" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AboveDeckProjectedWindEnd_2t7V67QC51PRcOCLDdpQcG" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AboveDeckProjectedWindSide_27Fti2ntX0dgiVBd5Ek6wY" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Displacement_1PidMMB0X0OQe7BvinOSOP" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CargoDeadWeight_2vVxFsGGb3QOAIX9UEyhga" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LaneMeters_1wIXrPLuDA1BAKRB9T3fjR" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2jQXB3neb0DhM8kWRPnVty" Name="Pset_MarineVehicleDesignCriteria" Description="Properties common to the definition of design criteria of all occurrences of _IfcTransportElement_ and types of _IfcTransportElementType_ with the predefined type set to MARINEVEHICLE" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcVehicle/VEHICLEMARINE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="AllowableHullPressure_3XuoFwqDfD$BTW3RD_z1qw" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SoftnessCoefficient_1TpFLgzCzFERpwNsg1t_hP" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2R1$NnDMc8PHP6QQEXnIM$" Name="Pset_MarkerGeneral" Description="Properties common to a signalling marker made as an assembly of elements. The property set can be used by the predefined type SIGNAL_ASSEMBLY of IfcElementAssembly." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcElementAssembly/SIGNALASSEMBLY">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ApproachSpeed_2khyDboNP4W87sfeq3cm4L" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MarkerType_2evuRsoi54$u$eV2ZYT$P_" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalHeight_00HWS0qUaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Symbol_1e6VoJKif46hPnVSUT$o5u" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalWidth_2YZfyYRY1Aa9bsWGvZEaNq" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2YakKAOZX2luo$SAzWQqbi" Name="Pset_MarkingLinesCommon" Description="Properties for line markings." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcSurfaceFeature/LINEMARKING">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="DashedLine_3suuc1XGL608tN2w9QsDL0" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DashedLinePattern_06qWfjkiXCOR1C_hUCX34b" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalWidth_2YZfyYRY1Aa9bsWGvZEaNq" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2lE180qUmHuO00025QrE$V" Name="Pset_MaterialCombustion" Description="A set of extended material properties of products of combustion generated by elements typically used within the context of building services and flow distribution systems." ApplicableEntity="IfcMaterial">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SpecificHeatCapacity_2szxQ0qUmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="N20Content_2yLG40qUmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="COContent_31iak0qUmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CO2Content_37g2o0qUmHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3Eppg0qUmHuO00025QrE$V" Name="Pset_MaterialCommon" Description="A set of general material properties." ApplicableEntity="IfcMaterial">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="MolecularWeight_3IOi60qUmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Porosity_3OMAA0qUmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MassDensity_3TjUq0qUmHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3Zgyu0qUmHuO00025QrE$V" Name="Pset_MaterialConcrete" Description="A set of extended mechanical properties related to concrete materials." ApplicableEntity="IfcMaterial">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="CompressiveStrength_3gEaM0qUmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaxAggregateSize_3mC2Q0qUmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AdmixturesDescription_3tLpI0qUmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Workability_3yj7y0qUmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WaterImpermeability_01UJC0qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ProtectivePoreRatio_07RnG0qUqHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0D$Ok0qUqHuO00025QrE$V" Name="Pset_MaterialEnergy" Description="A set of extended material properties for energy calculation purposes." ApplicableEntity="IfcMaterial">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ViscosityTemperatureDerivative_0IAQa0qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MoistureCapacityThermalGradient_0O7ue0qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ThermalConductivityTemperatureDerivative_0U5Mi0qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SpecificHeatTemperatureDerivative_0YsXy0qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VisibleRefractionIndex_0eq000qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SolarRefractionIndex_0lNdU0qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GasPressure_0qky80qUqHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0xIZc0qUqHuO00025QrE$V" Name="Pset_MaterialFuel" Description="A set of extended material properties of fuel energy typically used within the context of building services and flow distribution systems." ApplicableEntity="IfcMaterial">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="CombustionTemperature_0_tS20qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CarbonContent_14qw60qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LowerHeatingValue_1ACEm0qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HigherHeatingValue_1EzQ00qUqHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="33OPNTBiz86QXeNX0dlt3R" Name="Pset_MaterialGranular" Description="A set of extended properties related to granular materials." ApplicableEntity="IfcMaterial">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Grading_3hHDlpC554pggyHq6uRDZ7" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaxGrainSize_3YDB6b_Sf2KuuKISWe02i6" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1LX1U0qUqHuO00025QrE$V" Name="Pset_MaterialHygroscopic" Description="A set of hygroscopic properties of materials." ApplicableEntity="IfcMaterial">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="UpperVaporResistanceFactor_1P5vw0qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LowerVaporResistanceFactor_1Tt5A0qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsothermalMoistureCapacity_1ZEPq0qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VaporPermeability_1d$b40qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MoistureDiffusivity_1iAcw0qUqHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1o84_0qUqHuO00025QrE$V" Name="Pset_MaterialMechanical" Description="A set of mechanical material properties normally used for structural analysis purpose. It contains all properties which are independent of the actual material type." ApplicableEntity="IfcMaterial">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="DynamicViscosity_1sJ6q0qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulus_1x4I40qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShearModulus_20Rck0qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PoissonRatio_25Cn_0qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ThermalExpansionCoefficient_2BAG20qUqHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2HjtW0qUqHuO00025QrE$V" Name="Pset_MaterialOptical" Description="A set of optical properties of materials." ApplicableEntity="IfcMaterial">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="VisibleTransmittance_2LIly0qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SolarTransmittance_2SSWq0qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ThermalIrTransmittance_2XprU0qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ThermalIrEmissivityBack_2dBA80qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ThermalIrEmissivityFront_2iYUo0qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VisibleReflectanceBack_2tH860qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VisibleReflectanceFront_2zEcA0qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SolarReflectanceBack_33C4E0qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SolarReflectanceFront_37zFU0qUqHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3rus6bQLj4MgCigClH26Jf" Name="Pset_MaterialSolid" Description="A set of extended material properties of solid (natural) materials typically used within the context of geology and geotechnics." ApplicableEntity="IfcMaterial">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ZnContent_02nVJY8$5Dmgcog95HvuLM" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CuContent_0arger_T9BI8SOL5EIy2u7" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PbContent_1CZd8smoT6YPhHy6oCCq8c" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CrContent_0ijitX2mHAefsn6tigqyY3" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HgContent_1F_XTqiBD9dQNNlCtXJFbZ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NiContent_1dnmq$hVHFi9E_V6sx8uof" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AsContent_3gj7BIvwT8S8u8sGvaHIBb" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CdContent_0qniTK$wv25vsXuAYWfca9" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MnContent_0o8MhlkZ53UQY$AE8JFW5B" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OrganicMatterContent_0CMY_nRMTF7vr$SfHyXInr" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TS_3TIrUqMFzEHxl56bjVXyxc" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3UImIHbVT9tujbYTaOvHTv" Name="Pset_MaterialSprayedConcrete" Description="A set of properties related to sprayed concrete materials." ApplicableEntity="IfcMaterial">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="EarlyStrengthDevelopment_0xMZaUlN5EQRS7ruLVPHrd" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FibreType_0ZIZhcg8bFQgae_dc42mCB" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FibreVolumeRatio_1lDCr_KiHEZxCLwJ6YMCr2" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FibreLength_2UeiJ9HTnA0RPlmDtOHWGq" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FibreDiameter_2AiOsSAiPEYh8W2tTL3V$g" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AspectRatio_1fn65ZfW93URZlaV1DMSyD" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ResidualTensileStrengthfR1k_2tdtfQJTvDgxR2fqlv2GfM" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ResidualTensileStrengthfR3k_3eVnIQ8sXBYxb3JbnYq3du" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ResidualTensileStrengthfLk_3rh_yPnNbC7RdUAuRCMnHg" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ResidualStrengthStructualClass_2M4sn4MkvDoPCXacy2_xw0" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CompressiveStrength24h_3zFO54k7zE$hbebMKr9wo_" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CompressiveStrength48h_2wVaHRlavFw8VGNtRRpVJa" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EnergyAbsportionCapacity7d_07C5C3$vz6oRj$ZmfzEQj0" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EnergyAbsportionCapacity28d_3UejlFN5n7GRaO5BEtDnYA" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3EWsy0qUqHuO00025QrE$V" Name="Pset_MaterialSteel" Description="A set of extended mechanical properties related to steel (or other metallic and isotropic) materials." ApplicableEntity="IfcMaterial">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="YieldStress_3JuBc0qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UltimateStress_3Prfg0qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UltimateStrain_3VC_K0qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HardeningModule_3aaI_0qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ProportionalStress_3fxde0qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PlasticStrain_3lv5i0qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Relaxations_3rGQM0qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="StructuralGrade_2UyNw8E619$8aLUZDK0aNY" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="03Zy60qUuHuO00025QrE$V" Name="Pset_MaterialThermal" Description="A set of thermal material properties." ApplicableEntity="IfcMaterial">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SpecificHeatCapacity_078qY0qUuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BoilingPoint_0Bv$o0qUuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FreezingPoint_0HtTs0qUuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ThermalConductivity_0Nqxw0qUuHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0ToP_0qUuHuO00025QrE$V" Name="Pset_MaterialWater" Description="A set of extended material properties for of water typically used within the context of building services and flow distribution systems." ApplicableEntity="IfcMaterial">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsPotable_0XNIQ0qUuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Hardness_0dKmU0qUuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AlkalinityConcentration_0ii580qUuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AcidityConcentration_0o3Po0qUuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ImpuritiesContent_0sERe0qUuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DissolvedSolidsContent_0w$cu0qUuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PHLevel_0$mo80qUuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ElectricalConductivity_0JOFocHPD1Rxfnqm5NX9ca" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Temperature_0GSjm0qXCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Cl_1AyulzLmb7kh4MInlhCAEO" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NO3_2mojFkIZf0RgDdRrAmsAvG" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SO42_0U5FAS_db4URK3Zf0YMJDR" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HCO3_1Ov1VDlGf0wwH8$gwlFai2" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Na_1yejeoaXj1gAsLahNn8Fv1" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="K_2jm5TRU9TFhudeUCIbbCmE" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Mg2_0IKcZxoxn5JhgLbQZ83Wbl" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Ca2_10wmfjd5PB5xuqHQBOdisp" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1586o0qUuHuO00025QrE$V" Name="Pset_MaterialWood" Description="This is a collection of properties applicable to wood-based materials that specify kind and grade of material as well as moisture related parameters." ApplicableEntity="IfcMaterial">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Species_19J8e0qUuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="StrengthGrade_1EgTI0qUuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AppearanceGrade_1K1ny0qUuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Layup_1PP6c0qUuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Layers_1VMag0qUuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Plies_1ZXcW0qUuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MoistureContent_1dieM0qUuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DimensionalChangeCoefficient_1htgC0qUuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ThicknessSwelling_1merS0qUuHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1rQ0i0qUuHuO00025QrE$V" Name="Pset_MaterialWoodBasedBeam" Description="This is a collection of mechanical properties applicable to wood-based materials for beam-like products, especially laminated materials like glulam and LVL.
Anisotropy of such materials is taken into account by different properties according to grain direction and load types.

All values shall be given for a standardized service condition, a standardized load duration and a standardized reference size of the member according to local design codes.

NOTE: In cases where mechanical material properties are graduated for different given reference sizes, separate instances of IfcExtendedMaterialProperties and IfcMaterial have to be used for each required graduation. Mechanically differing versions of a material are treated as different materials.

References to the orientation of grain or lay-up correspond to material orientation given by geometrical or topological representation of element objects or types, especially IfcMemberType and IfcStructuralMember." ApplicableEntity="IfcMaterial/Wood">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ApplicableStructuralDesignMethod_1uOlk0qUuHuO00025QrE$V" />
						<IfcComplexPropertyTemplate xsi:nil="true" href="InPlane_1zm4O0qUuHuO00025QrE$V" />
						<IfcComplexPropertyTemplate xsi:nil="true" href="InPlaneNegative_3Ddmq0qUuHuO00025QrE$V" />
						<IfcComplexPropertyTemplate xsi:nil="true" href="OutOfPlane_0WUCI0qUyHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1okUM0qUyHuO00025QrE$V" Name="Pset_MaterialWoodBasedPanel" Description="This is a collection of mechanical properties related to wood-based materials for panel-like products like plywood or OSB. The propositions given above for wood-based beam materials with respect to anisotropy, strength graduation according to element sizes (especially panel thickness) apply accordingly." ApplicableEntity="IfcMaterial/Wood">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ApplicableStructuralDesignMethod_1rjDO0qUyHuO00025QrE$V" />
						<IfcComplexPropertyTemplate xsi:nil="true" href="InPlane_1x4Y20qUyHuO00025QrE$V" />
						<IfcComplexPropertyTemplate xsi:nil="true" href="OutOfPlane_3bAiM0qUyHuO00025QrE$V" />
						<IfcComplexPropertyTemplate xsi:nil="true" href="OutOfPlaneNegative_1H3Iu0qV0HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3ALWeZ7o50DfXc6j$jz4Xr" Name="Pset_MaterialWoodBasedStructure" Description="Properties about Material of Wood Based Structure." ApplicableEntity="IfcMaterial">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ApplicableStructuralDesignMethod_3Fuv3RpRzFVwibS5OOzpOY" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1fyrQvTg5Bag0x3Y$2ag9b" Name="Pset_MechanicalBeamInPlane" Description="Properties about Mechanical Beam in Plane." ApplicableEntity="IfcMaterial">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulus_1x4I40qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulusMin_1GWNFoFaz07OonloBxZUIU" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulusPerp_0hIiFZeVTDb921yIdyCwiO" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulusPerpMin_0X8QZuXmT2JfERY_t1KRKN" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShearModulus_20Rck0qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShearModulusMin_0BABvT9ifCweKQpbVbmW1v" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BendingStrength_1mJcyU5FjEvPlHNmb60SjF" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TensileStrength_1ZuJdL4cPBOuLWEzKCV5K4" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TensileStrengthPerp_0j8x5DwHH4rgxxNUUYpaxH" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CompStrength_0KKYZceoj1zOtGz8I7XmVq" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CompStrengthPerp_0Sk7rdMlL1rwa$77Tmc3ZF" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RaisedCompStrengthPerp_04LOOIhZr3DBc$B7zq9dxk" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShearStrength_0kjgupy_97avIlMZH_iBD4" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TorsionalStrength_0S_uq2KWrCDQRWW5W4PUOa" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReferenceDepth_18i26IeYfElf48a3m5DXxE" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InstabilityFactors_06AWQ0_jj70ukx9CZSEl7o" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="085BgaLPH82hqR8VQFnfSo" Name="Pset_MechanicalBeamInPlaneNegative" Description="Properties about Mechanical Beam in Plane Negative." ApplicableEntity="IfcMaterial">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulus_1x4I40qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulusMin_1GWNFoFaz07OonloBxZUIU" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulusPerp_0hIiFZeVTDb921yIdyCwiO" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulusPerpMin_0X8QZuXmT2JfERY_t1KRKN" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShearModulus_20Rck0qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShearModulusMin_0BABvT9ifCweKQpbVbmW1v" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BendingStrength_1mJcyU5FjEvPlHNmb60SjF" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TensileStrength_1ZuJdL4cPBOuLWEzKCV5K4" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TensileStrengthPerp_0j8x5DwHH4rgxxNUUYpaxH" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CompStrength_0KKYZceoj1zOtGz8I7XmVq" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CompStrengthPerp_0Sk7rdMlL1rwa$77Tmc3ZF" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RaisedCompStrengthPerp_04LOOIhZr3DBc$B7zq9dxk" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShearStrength_0kjgupy_97avIlMZH_iBD4" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TorsionalStrength_0S_uq2KWrCDQRWW5W4PUOa" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReferenceDepth_18i26IeYfElf48a3m5DXxE" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InstabilityFactors_06AWQ0_jj70ukx9CZSEl7o" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0g5cIEwDf8sucEBxFDnlnR" Name="Pset_MechanicalBeamOutOfPlane" Description="Properties about Mechanical Beam Out Of Plane." ApplicableEntity="IfcMaterial">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulus_1x4I40qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulusMin_1GWNFoFaz07OonloBxZUIU" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulusPerp_0hIiFZeVTDb921yIdyCwiO" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulusPerpMin_0X8QZuXmT2JfERY_t1KRKN" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShearModulus_20Rck0qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShearModulusMin_0BABvT9ifCweKQpbVbmW1v" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BendingStrength_1mJcyU5FjEvPlHNmb60SjF" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TensileStrength_1ZuJdL4cPBOuLWEzKCV5K4" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TensileStrengthPerp_0j8x5DwHH4rgxxNUUYpaxH" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CompStrength_0KKYZceoj1zOtGz8I7XmVq" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CompStrengthPerp_0Sk7rdMlL1rwa$77Tmc3ZF" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RaisedCompStrengthPerp_04LOOIhZr3DBc$B7zq9dxk" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShearStrength_0kjgupy_97avIlMZH_iBD4" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TorsionalStrength_0S_uq2KWrCDQRWW5W4PUOa" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReferenceDepth_18i26IeYfElf48a3m5DXxE" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InstabilityFactors_06AWQ0_jj70ukx9CZSEl7o" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2yxvQ0qV0HuO00025QrE$V" Name="Pset_MechanicalFastenerAnchorBolt" Description="Properties common to different types of anchor bolts." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcMechanicalFastener/ANCHORBOLT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="AnchorBoltLength_33VWu0qV0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AnchorBoltDiameter_3A38M0qV0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AnchorBoltThreadLength_3Hp2e0qV0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AnchorBoltProtrusionLength_3OypW0qV0HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3YVA00qV0HuO00025QrE$V" Name="Pset_MechanicalFastenerBolt" Description="Properties related to bolt-type fasteners. The properties of a whole set with bolt, washers and nut may be provided. Note, it is usually not necessary to transmit these properties in case of standardized bolts. Instead, the standard is referred to." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcMechanicalFastener/BOLT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ThreadDiameter_3dsUg0qV0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ThreadLength_3kQ680qV0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NutsCount_3qNaC0qV0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WashersCount_3wL2G0qV0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HeadShape_3$6DW0qV0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="KeyShape_05fq_0qV4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NutShape_0BdJ20qV4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WasherShape_0TVjE0qV4HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2g8KPoQI$i3hxt2KtfzH6x" Name="Pset_MechanicalFastenerOCSFitting" Description="Common properties of clamps and fittings used in railway overhead contact system (OCS)." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcMechanicalFastener/COUPLER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ManufacturingTechnology_3184bedm1EBOAi0U5_PkrQ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OCSFasteningType_2gURBVuJP1TgJZ3PaUKlJ7" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2jStVO_lmEb$eDbMGsJNkS" Name="Pset_MechanicalFastenerTypeRailFastening" Description="Properties of rail fastening used in railway track system. The property set can be used by the predefined type RAILFASTENING of IfcMechanicalFastener." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcMechanicalFastener/RAILFASTENING">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="TechnicalStandard_2M$Q1oBlHFBhUArnmHLc4W" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsReducedResistanceFastening_0DOivAfc56c81gaVUiqBi8" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TrackFasteningElasticityType_3je6qR3bvASesRirl5KDGp" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2ALrJdj40jLZWAU2aFfHFk" Name="Pset_MechanicalFastenerTypeRailJoint" Description="Properties common to a rail joint of a railway track system. The property set can be used by the predefined type RAILJOINT of IfcMechanicalFastener." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcMechanicalFastener/RAILJOINT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SleeperArrangement_24pyO2n$n5EOpil0HhjmwF" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsCWRJoint_2aTez2BlX6R85Py6sJk$MW" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsJointInsulated_0V_bDkEFz0MBUJ_PVJB5bz" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsLiftingBracketConnection_0b7QU$LAbEywG5aCANU6MN" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfScrews_2if5qEscD9_PYBlf2PakRS" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RailGap_0$Ooq6bAz7GfDzJmMijf3H" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsJointControlEquipment_1y8uHbp6z5vfRtA_1nm6D8" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AssemblyPlace_1YL3k0qUmHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0Y$x1ChRf5zOo95PhOPodS" Name="Pset_MechanicalPanelInPlane" Description="Properties for Mechanical Panels In Plane." ApplicableEntity="IfcMaterial">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulusBending_2iUxE2okX3qe97DmCl4Kk0" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulusTension_0iG4nofBX9zgQRpfqFJpVy" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulusCompression_0rZyHKD5H1QQmUECnOzXOq" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShearModulus_20Rck0qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BendingStrength_1oJsaXinL0WvDVCL88_ITB" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CompressiveStrength_0gx8OSAsfDaR6Lagjl0obi" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TensileStrength_0hLYMBp_XD19T1MBlKy5SN" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShearStrength_1AG3tFK1rEUBNEvoZ2jg2s" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BearingStrength_0KJTgColX9Se1gcILtKvQM" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RaisedCompressiveStrength_24vkFVO3zF59eFBHZdlOH3" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReferenceDepth_18i26IeYfElf48a3m5DXxE" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0fB18sxAnF4etUeGtNpB4B" Name="Pset_MechanicalPanelOutOfPlane" Description="Properties for Mechanical Panels Out Of Plane." ApplicableEntity="IfcMaterial">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulusBending_2iUxE2okX3qe97DmCl4Kk0" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulusTension_0iG4nofBX9zgQRpfqFJpVy" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulusCompression_0rZyHKD5H1QQmUECnOzXOq" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShearModulus_20Rck0qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BendingStrength_1oJsaXinL0WvDVCL88_ITB" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CompressiveStrength_0gx8OSAsfDaR6Lagjl0obi" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TensileStrength_0hLYMBp_XD19T1MBlKy5SN" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShearStrength_1AG3tFK1rEUBNEvoZ2jg2s" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BearingStrength_0KJTgColX9Se1gcILtKvQM" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RaisedCompressiveStrength_24vkFVO3zF59eFBHZdlOH3" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReferenceDepth_18i26IeYfElf48a3m5DXxE" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3_CoRM2b1BYfP3KFzJZEy3" Name="Pset_MechanicalPanelOutOfPlaneNegative" Description="Properties for Mechanical Panels Out Of Plane Negative." ApplicableEntity="IfcMaterial">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulusBending_2iUxE2okX3qe97DmCl4Kk0" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulusTension_0iG4nofBX9zgQRpfqFJpVy" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YoungModulusCompression_0rZyHKD5H1QQmUECnOzXOq" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShearModulus_20Rck0qUqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BendingStrength_1oJsaXinL0WvDVCL88_ITB" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CompressiveStrength_0gx8OSAsfDaR6Lagjl0obi" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TensileStrength_0hLYMBp_XD19T1MBlKy5SN" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShearStrength_1AG3tFK1rEUBNEvoZ2jg2s" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BearingStrength_0KJTgColX9Se1gcILtKvQM" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RaisedCompressiveStrength_24vkFVO3zF59eFBHZdlOH3" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReferenceDepth_18i26IeYfElf48a3m5DXxE" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0bFdW0qV4HuO00025QrE$V" Name="Pset_MedicalDeviceTypeCommon" Description="Medical device type common attributes." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcMedicalDevice">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_0l_Gq0qV4HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0$U5O0qV4HuO00025QrE$V" Name="Pset_MemberCommon" Description="Properties common to the definition of all occurrences of IfcMember." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcMember">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_1Fa3M0qV4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Span_1Ttb60qV4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Slope_1aRCa0qV4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Roll_1fCNq0qV4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsExternal_1kZiU0qV4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ThermalTransmittance_1qXAY0qV4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LoadBearing_1wUec0qV4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FireRating_20S6g0qV4HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3IqFanTEh5zSoH4oObc5vs" Name="Pset_MemberTypeAnchoringBar" Description="Properties of anchoring bar. The anchoring bar is used to connect stay from pole to the foundation." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcMember/BRACE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="MechanicalStressType_0Xzh3BeoP5H9lg8s_GLbSq" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WithLightningRod_3pPNiRy4X9KvANfnRk92$0" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2nNlyXlJ$V28igwN8kSx5D" Name="Pset_MemberTypeCatenaryStay" Description="Properties of catenary stay used in railway. The property set can be used by the predefined type STAY_CABLE of IfcMember." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcMember/STAY_CABLE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="AssemblyInstruction_3W5i6nbkP9NBt_M6PTB5jW" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalLength_0NS18P1J51kRFniH3h5CIL" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CatenaryStayType_0t_MO24RnC$BoGLPbf_Vc7" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalHeight_1Fy4XYaJXDTBDDb9f06ofi" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0tpeH7AX7dn7uYWe9zsKdt" Name="Pset_MemberTypeOCSRigidSupport" Description="Properties of rigid catenary support used in railway overhead contact system." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcMember/MEMBER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="AssemblyInstruction_3W5i6nbkP9NBt_M6PTB5jW" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ContactWireStagger_1dWD_52DDFheUkLfvK_Wga" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1Yl6GaFOTAew0nhXJXuBx8" Name="Pset_MemberTypePost" Description="Properties of a post. A post is a linear (usually vertical) member used to support something or to mark a point." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcMember/POST">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalHeight_1Fy4XYaJXDTBDDb9f06ofi" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConicityRatio_1q2DJWtf58PvkMOQBrIqOF" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LoadBearingCapacity_2RBEe0qSKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WindLoadRating_1cI8AXMuf208Vs_0Pmo_8B" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TorsionalStrength_0S_uq2KWrCDQRWW5W4PUOa" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BendingStrength_1mJcyU5FjEvPlHNmb60SjF" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2n$IX4KDSzzS0U_a_bAgx4" Name="Pset_MemberTypeTieBar" Description="Properties of tie bar. A tie bar is a linear bar element used to secure or stabilise a structure by resisting lateral and longitudinal loading through tension and or compression. usually formed by a solid bar." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcMember/TIEBAR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsTemporaryInstallation_3I8hgbGqb2cwnJJlcup1s_" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3NqegCizbm381JGDMh8gMZ" Name="Pset_MobileTelecommunicationsApplianceTypeAccessPoint" Description="Properties common to the definition of all occurrences of  _IfcMobileTelecommunicationsAppliance_ and types of _IfcMobileTelecommunicationsApplianceType_ with the predefined type set to ACCESSPOINT." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcMobileTelecommunicationsAppliance/ACCESSPOINT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="BandWidth_3qGbr0Q199cuUUYiO3nY0i" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DataEncryptionType_0pqbO0sVjBRR5HyenyysRl" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DataExchangeRate_2AuHR1lx11mP7sIpwz9u8Z" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfAntennas_3pcohitgD84wYzTL$rzTOJ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfInterfaces_3D0wHuI4P3guCzHoS3Y4Zf" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UserCapacity_2eXzZatEr5bOQ1ApLLVBvv" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3Aa0Ll$aE3gCjsAisQt9Y1" Name="Pset_MobileTelecommunicationsApplianceTypeBasebandUnit" Description="Properties common to the definition of all occurrences of  _IfcMobileTelecommunicationsAppliance_ and types of _IfcMobileTelecommunicationsApplianceType_ with the predefined type set to BASEBANDUNIT." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcMobileTelecommunicationsAppliance/BASEBANDUNIT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfCarriers_07xDxpcsn6yA144GO_a3fc" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfInterfaces_3D0wHuI4P3guCzHoS3Y4Zf" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfEmergencyTransceivers_2RrzYcZZf2sO3dp5bbzVgl" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumNumberOfRRUs_0tAsowuCH8xgtZ_ZgM$4Ug" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1vfQQBdLJY7_ZnUa7qLRI4" Name="Pset_MobileTelecommunicationsApplianceTypeBaseTransceiverStation" Description="Properties common to the definition of all occurrences of  _IfcMobileTelecommunicationsAppliance_ and types of _IfcMobileTelecommunicationsApplianceType_ with the predefined type set to BASETRANSCEIVERSTATION." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcMobileTelecommunicationsAppliance/BASETRANSCEIVERSTATION">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="DownlinkRadioBand_2dhC8V9VzBAxjON4waRpK9" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfCarriers_07xDxpcsn6yA144GO_a3fc" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfAntennas_3pcohitgD84wYzTL$rzTOJ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UplinkRadioBand_16u1AonQD7qeK0DpO8DyYZ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ExchangeCapacity_3BKPzAHt10s8UrVNVqgpxw" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfEmergencyTransceivers_2RrzYcZZf2sO3dp5bbzVgl" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfTransceiversPerAntenna_0_R58gpyn2cPydhUJjYefc" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RadiatedOutputPowerPerAntenna_1uH9Rio6XFy8Z6EBj1Yjbb" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfInterfaces_3D0wHuI4P3guCzHoS3Y4Zf" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3pWyJDmZ1AvBjUxT4v4XHE" Name="Pset_MobileTelecommunicationsApplianceTypeCommon" Description="Properties common to the definition of all occurrences of  _IfcMobileTelecommunicationsAppliance_ and types of _IfcMobileTelecommunicationsApplianceType_." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcMobileTelecommunicationsAppliance">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_002JG0qWWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1GhvAf6Kqd_NFyfq4OkD5u" Name="Pset_MobileTelecommunicationsApplianceTypeEUtranNodeB" Description="Properties common to the definition of all occurrences of  _IfcMobileTelecommunicationsAppliance_ and types of _IfcMobileTelecommunicationsApplianceType_ with the predefined type set to E_UTRAN_NODE_B." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcMobileTelecommunicationsAppliance/E_UTRAN_NODE_B">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="DownlinkRadioBand_2dhC8V9VzBAxjON4waRpK9" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfCarriers_07xDxpcsn6yA144GO_a3fc" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RadiatedOutputPowerPerAntenna_1uH9Rio6XFy8Z6EBj1Yjbb" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfAntennas_3pcohitgD84wYzTL$rzTOJ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfInterfaces_3D0wHuI4P3guCzHoS3Y4Zf" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UplinkRadioBand_16u1AonQD7qeK0DpO8DyYZ" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3AFBnHraw22Yy3zNwwpdot" Name="Pset_MobileTelecommunicationsApplianceTypeMasterUnit" Description="Properties common to the definition of all occurrences of  _IfcMobileTelecommunicationsAppliance_ and types of _IfcMobileTelecommunicationsApplianceType_ with the predefined type set to MASTERUNIT." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcMobileTelecommunicationsAppliance/MASTERUNIT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfInterfaces_3D0wHuI4P3guCzHoS3Y4Zf" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumNumberOfConnectedRUs_04WFhKT_r5UgPl35B9Wrbd" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TransmissionType_0F7760u3z29Q0oq6yXepYZ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TransmittedBandwidth_2x5FCzOXX65wSk8PZymLiB" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TransmittedFrequency_0b56gXbrD1LxWzOSRwnBOh" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TransmittedSignal_1zo$ODEpL3mPUPdtAGuFyg" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MasterUnitType_0QeUyL0pf4MOJiDslA49ZJ" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0KvDK3SXkGJ$jr6yyPkExu" Name="Pset_MobileTelecommunicationsApplianceTypeMobileSwitchingCenter" Description="Properties common to the definition of all occurrences of  _IfcMobileTelecommunicationsAppliance_ and types of _IfcMobileTelecommunicationsApplianceType_ with the predefined type set to MOBILESWITCHINGCENTER." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcMobileTelecommunicationsAppliance/MOBILESWITCHINGCENTER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="UserCapacity_2eXzZatEr5bOQ1ApLLVBvv" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfInterfaces_3D0wHuI4P3guCzHoS3Y4Zf" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumNumberOfManagedBSCs_2y9Cxd6R9B5xNzs7Z2VO_B" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1txuCh8qD97isyGULVa9U8" Name="Pset_MobileTelecommunicationsApplianceTypeMSCServer" Description="Properties common to the definition of all occurrences of  _IfcMobileTelecommunicationsAppliance_ and types of _IfcMobileTelecommunicationsApplianceType_ with the predefined type set to MSCSERVER." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcMobileTelecommunicationsAppliance/MSCSERVER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="UserCapacity_2eXzZatEr5bOQ1ApLLVBvv" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfInterfaces_3D0wHuI4P3guCzHoS3Y4Zf" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2cYlW8vNA2k5MDluEQh_1Q" Name="Pset_MobileTeleCommunicationsApplianceTypeRemoteRadioUnit" Description="Properties common to the definition of all occurrences of  _IfcMobileTelecommunicationsAppliance_ and types of _IfcMobileTelecommunicationsApplianceType_ with the predefined type set to REMOTERADIOUNIT." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcMobileTelecommunicationsAppliance/REMOTERADIOUNIT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="DownlinkRadioBand_2dhC8V9VzBAxjON4waRpK9" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfCarriers_07xDxpcsn6yA144GO_a3fc" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfInterfaces_3D0wHuI4P3guCzHoS3Y4Zf" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UplinkRadioBand_16u1AonQD7qeK0DpO8DyYZ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfTransceiversPerAntenna_0_R58gpyn2cPydhUJjYefc" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RadiatedOutputPowerPerAntenna_1uH9Rio6XFy8Z6EBj1Yjbb" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AntennaType_2PysPrqKj3aPWcff71DZsA" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RRUConnectionType_2llH13$EvAY8Lc9VG04k0Z" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="28ZmeFSQCeduQEyzj0bCRT" Name="Pset_MobileTelecommunicationsApplianceTypeRemoteUnit" Description="Properties common to the definition of all occurrences of  _IfcMobileTelecommunicationsAppliance_ and types of _IfcMobileTelecommunicationsApplianceType_ with the predefined type set to REMOTEUNIT." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcMobileTelecommunicationsAppliance/REMOTEUNIT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfInterfaces_3D0wHuI4P3guCzHoS3Y4Zf" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfAntennas_3pcohitgD84wYzTL$rzTOJ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RUConnectionType_3QHGcFv6z8IQq_4_0gv5Jf" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="04iFFjY7D2iQ_8qPzA8WLQ" Name="Pset_MooringDeviceCommon" Description="Properties common to the definition of all occurrences of _IfcMooringDevice_ and types of _IfcMooringDeviceType_." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcMooringDevice,IfcMooringDeviceType">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="DeviceType_3IIklEVDz3j9xOl8NCkENp" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DeviceCapacity_2jcue8hCf9rP2okPzNVte5" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AnchorageType_2UZ$AxwvT8QOGM0IC5$_Zf" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MinumumLineSlope_0yz2ivXvf3NhJNscddZLN0" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumLineSlope_1frxgl$J1Dfv_kLsxsJGec" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumLineCount_28WAQCcEb5o8xMtoO1rOHY" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="27btY0qV4HuO00025QrE$V" Name="Pset_MotorConnectionTypeCommon" Description="Common properties for motor connections. HISTORY: Added in IFC4." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcMotorConnection">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_2IwgG0qV4HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1_ee0_i3P46hIY_PhccyLw" Name="Pset_OnSiteCastKerb" Description="Properties for an on site cast kerb." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcKerb">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalHeight_1Fy4XYaJXDTBDDb9f06ofi" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalWidth_2YZfyYRY1Aa9bsWGvZEaNq" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0UH9ldEP_WEw6XxFg7snx2" Name="Pset_OnSiteTelecomControlUnit" Description="Properties for on-site telecom control unit used for railway." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcController">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasEarthquakeAlarm_0i3RXtiWP9gu0kcIEX$cps" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasEarthquakeCollection_2qgOIv5sT2oOCmdiwvsqux" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasForeignObjectCollection_03AHgrStD9A9uC$wqdCY0t" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SerialInterfaceType_0IV69mrp50xeArXDuk$7Y6" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasOutputFunction_25A5PIA$n5iuwbGGAHxZMC" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasRainCollection_1uNBZEuvj1U9OHpOMzUZZd" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasSnowCollection_32JgEUdsb4S9ibZdwzo4JR" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasWindCollection_1NbgJQZBv91wp1sKWotMbx" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2YQUq0qV4HuO00025QrE$V" Name="Pset_OpeningElementCommon" Description="Properties common to the definition of all instances of IfcOpeningElement." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcOpeningElement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_2j9880qV4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Purpose_2wsWU0qV4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FireExit_30p_Y0qV4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FireRating_1m6F5jtsz3BApAikzRRd5J" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AcousticRating_13UqKWrSfDIwPMac2f7fRy" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0bWLntQVYpNxebaJqY8SRf" Name="Pset_OpticalAdapter" Description="Properties in this property set are applicable to the transition type of cable fitting. Indicated that such transition is an optical adapter." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCableFitting/TRANSITION">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="FiberType_33hW6SI9L88u4r9StkBaiz" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3EG4AlOug4T0KXTXHONGcC" Name="Pset_OpticalPigtail" Description="Property set for optical pigtail. This property set is applicable to a type or occurrence of _IfcCableSegment_ with predefined type OPTICALCABLESEGMENT." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCableSegment/OPTICALCABLESEGMENT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="JacketColour_1vHztIiLn2ZvG$H5JLPMVP" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FiberType_33hW6SI9L88u4r9StkBaiz" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConnectorType_3hZprW7ZTEuRugKKQVaEZ3" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2ThYcj8E$s4U3qsZ4Kg99b" Name="Pset_OpticalSplitter" Description="Properties of optical splitter used in the telecommunication domain. This property set can be used by the predefined type DATA of IfcJunctionBox." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcJunctionBox/DATA">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfBranches_0bANhcBav7EhQtQmEUQDDQ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OpticalSplitterType_01LueCMJjAXuijkI5GImgq" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfInterfaces_3D0wHuI4P3guCzHoS3Y4Zf" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3DxDU0qV4HuO00025QrE$V" Name="Pset_OutletTypeCommon" Description="Common properties for different outlet types." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcOutlet">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_3PG0C0qV4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsPluggableOutlet_3e9hM0qV4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfSockets_3vt4ImC_v7wAtg_xlI2htO" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3jX000qV4HuO00025QrE$V" Name="Pset_OutsideDesignCriteria" Description="Outside air conditions used as the basis for calculating thermal loads at peak conditions, as well as the weather data location from which these conditions were obtained. HISTORY: New property set in IFC Release 1.0." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcBuilding">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="HeatingDryBulb_3ouKg0qV4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HeatingWetBulb_3urok0qV4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HeatingDesignDay_3_pGo0qV4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoolingDryBulb_03aS20qV8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoolingWetBulb_08xmi0qV8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoolingDesignDay_0EJ5M0qV8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WeatherDataStation_0J4Gc0qV8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WeatherDataDate_0ORbG0qV8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BuildingThermalExposure_0Scd60qV8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PrevailingWindDirection_0dxPq0qV8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PrevailingWindVelocity_0jIkU0qV8HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0psLy0qV8HuO00025QrE$V" Name="Pset_PackingInstructions" Description="Packing instructions are specific instructions relating to the packing that is required for an artifact in the event of a move (or transport)." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcTask/MOVE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="PackingCareType_0xcGE0qV8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WrappingMaterial_17XCM0qV8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ContainerMaterial_1EgzE0qV8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SpecialInstructions_1H3Ys0qV8HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="26f$bXUpj0yuOrCagf9woK" Name="Pset_PatchCordCable" Description="This property set has properties that are applicable to cable segment and optical cable segment, indicated that the cable is a patch cord cable, which is fitted with connectors at both ends, allowing it to be rapidly and conveniently connected to other cables or to distribution panels." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCableSegment/CABLESEGMENT,IfcCableSegment/OPTICALCABLESEGMENT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="JacketColour_1vHztIiLn2ZvG$H5JLPMVP" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1RfJvfzsXFFelpZT_RNKUl" Name="Pset_PavementCommon" Description="Describes the common properties and nominal dimensions of pavement.

**Property use clarification**
The nominal thickness of the pavement remains constant with the value from NominalThickness, unless the property NominalThicknessEnd is provided. In which case NominalThickness is the value at the beginning of a transition (usually at the object placement location). e.g. a (road) transition segment where the pavement object&apos;s linear placement along an alignment denotes the beginning location and NominalThicknessEnd is the value at the end as indicated by the property NominalLength. In the case of local placements, it is user defined along which axis lengths and widths are measured." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcPavement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalThicknessEnd_2dzrJAQ351fhj1A45yJpqq" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_002JG0qWWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="StructuralSlope_0p7_egygj3puc4u$Co$FM1" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="StructuralSlopeType_3xWq8r8qv1fe3unGZTNN_f" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalWidth_2YZfyYRY1Aa9bsWGvZEaNq" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalLength_07RHK0qUaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalThickness_2QgJLpWOb3xfvwr_YO$T_k" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2oCzTUr0n5ORBUf$CjSJH2" Name="Pset_PavementMillingCommon" Description="Properties for pavement milling." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcEarthworksCut/PAVEMENTMILLING">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalDepth_0HZnE0qUaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalWidth_2YZfyYRY1Aa9bsWGvZEaNq" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="04I2EFunL3mP31LUo4SW4J" Name="Pset_PavementSurfaceCommon" Description="Properties for a pavement surface." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcPavement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="PavementRoughness_0r0gPVvcv1KPzot2_9fVt7" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PavementTexture_1JGNfhUnbBFe5yEOD_A8Fp" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1WOJ15V3r2aA3qTcs8dFJw" Name="Pset_PermeableCoveringProperties" Description="Properties of the permeable covering.

&gt;HISTORY&amp;nbsp; New property set in IFC4.3.2.0 to replace the entity IfcPermeableCoveringProperties" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDoor,IfcMember,IfcWindow">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="OperationType_1hpyRfu7HD7h$V2CjmYqL6" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PanelPosition_1y5RmsTUr2$RZ5QEXtb7tt" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FrameDepth_0IwU5LmKj0KPHgy8pFmJVV" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FrameThickness_2EJVRwHkn2zAJrpCfm_8dS" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1OpT80qV8HuO00025QrE$V" Name="Pset_Permit" Description="A permit is a document that allows permission to gain access to an area or carry out work in a situation where security or other access restrictions apply.
HISTORY: IFC4 EndDate added. PermitType, PermitDuration, StartTime and EndTime are deleted." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcPermit">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="EscortRequirement_1TaeO0qV8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="StartDate_1ZY6S0qV8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EndDate_1fVaW0qV8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SpecialRequirements_1kGlm0qV8HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1rQWe0qV8HuO00025QrE$V" Name="Pset_PileCommon" Description="Properties common to the definition of all occurrences of IfcPile." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcPile">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_10ebfaOlX82fn9pBND2gTI" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LoadBearing_1cDoRk08vDj9jlUoQLAX$f" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="25WUc0qV8HuO00025QrE$V" Name="Pset_PipeConnectionFlanged" Description="This property set is used to define the specifics of a flanged pipe connection used between occurrences of pipe segments and fittings." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcPipeSegment">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="FlangeTable_2C4640qV8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FlangeStandard_2Jq0M0qV8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BoreSize_2QNdq0qV8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FlangeDiameter_2Y7Y60qV8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FlangeThickness_2ftSO0qV8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfBoltholes_2n1DG0qV8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BoltSize_2sOXw0qV8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BoltholePitch_2yL$_0qV8HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="345wG0qV8HuO00025QrE$V" Name="Pset_PipeFittingOccurrence" Description="Pipe segment occurrence attributes attached to an instance of IfcPipeSegment." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcPipeFitting">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="InteriorRoughnessCoefficient_39TEw0qV8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Colour_3G0sO0qV8HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3OMw40qV8HuO00025QrE$V" Name="Pset_PipeFittingPHistory" Description="Pipe fitting performance history common attributes." TemplateType="pset_performancedriven" ApplicableEntity="IfcPipeFitting">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="LossCoefficient_3UKO80qV8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FlowrateLeakage_3XJ7A0qV8HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3cgRq0qV8HuO00025QrE$V" Name="Pset_PipeFittingTypeBend" Description="Pipe fitting type attributes for bend shapes." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcPipeFitting/BEND">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="BendAngle_3jE3I0qV8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BendRadius_3obNy0qV8HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3wLIE0qV8HuO00025QrE$V" Name="Pset_PipeFittingTypeCommon" Description="Pipe fitting type common attributes." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcPipeFitting">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_05g4y0qVCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PressureClass_0MyLk0qVCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PressureRange_0SJgO0qVCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TemperatureRange_0bs0u0qVCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FittingLossFactor_0jbxA0qVCHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0qli20qVCHuO00025QrE$V" Name="Pset_PipeFittingTypeJunction" Description="Pipe fitting type attributes for junction shapes." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcPipeFitting/JUNCTION">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="JunctionType_0vWtI0qVCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="JunctionLeftAngle_161yq0qVCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="JunctionLeftRadius_1Ap840qVCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="JunctionRightAngle_1J9Bm0qVCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="JunctionRightRadius_1NwN00qVCHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1Wsa60qVCHuO00025QrE$V" Name="Pset_PipeSegmentOccurrence" Description="Pipe segment occurrence attributes attached to an instance of IfcPipeSegment." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcPipeSegment">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="InteriorRoughnessCoefficient_39TEw0qV8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Colour_3G0sO0qV8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Gradient_1pL7i0qVCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InvertElevation_1vIbm0qVCHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1$G3q0qVCHuO00025QrE$V" Name="Pset_PipeSegmentPHistory" Description="Pipe segment performance history common attributes." TemplateType="pset_performancedriven" ApplicableEntity="IfcPipeSegment">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="LeakageCurve_24dOU0qVCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FluidFlowLeakage_27c7W0qVCHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2Bn9M0qVCHuO00025QrE$V" Name="Pset_PipeSegmentTypeCommon" Description="Pipe segment type common attributes." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcPipeSegment">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_2Ni5U0qVCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WorkingPressure_2dBw20qVCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PressureRange_2jlXW0qVCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TemperatureRange_2tu1Q0qVCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalDiameter_30E560qVCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InnerDiameter_37z$O0qVCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OuterDiameter_3F7mG0qVCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Length_1vU7rvwzz399ndMv3e5Cw7" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3MtgY0qVCHuO00025QrE$V" Name="Pset_PipeSegmentTypeCulvert" Description="Covered channel or large pipe that forms a watercourse below ground level, usually under a road or railway (BS6100)." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcPipeSegment/CULVERT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="InternalWidth_3Rero0qVCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ClearDepth_3Yocg0qVCHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3fyNY0qVCHuO00025QrE$V" Name="Pset_PipeSegmentTypeGutter" Description="Gutter segment type common attributes." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcPipeSegment/GUTTER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Slope_3kjYo0qVCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FlowRating_3q4tS0qVCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Complementaryfunction_0NZNNBTeH4$RmON2XH6spL" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OrthometricHeight_3pWIuI7GX20gqJ$iYrynJl" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsCovered_2YzvRQEzP4dh97Y5815zNr" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsMonitored_3KGj0PEan4G86e5DwEt_YL" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3weUw0qVCHuO00025QrE$V" Name="Pset_PlateCommon" Description="Properties common to the definition of all occurrences of IfcPlate." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcPlate">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_08y0g0qVGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AcousticRating_0aywm0qVGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsExternal_0ORrE0qVGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ThermalTransmittance_0nU0I0qVGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LoadBearing_0UPJI0qVGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FireRating_0i6he0qVGHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1ADJrYeAPDM9icpSRm7ugy" Name="Pset_PointMachine" Description="Properties of point machine used in railway. The property set can be used by IfcActuator with predefined type set to ELECTRICACTUATOR, HYDRAULICACTUATOR, HANDOPERATEDACTUATOR, or PNEUMATICACTUATOR, indicated that such actuator is a point machine that can switch and lock the track turnout." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcActuator/ELECTRICACTUATOR,IfcActuator/HYDRAULICACTUATOR,IfcActuator/HANDOPERATEDACTUATOR,IfcActuator/PNEUMATICACTUATOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ActionBarMovementLength_3g9eB0$QrCGgwW7XmrxaeO" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TractionForce_1h6R3D6qz8J9tT_sZdxp1y" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConversionTime_05csar1WP7SPvQFGopUOit" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LockingForce_0pLtPGaujDkwK16bnNbYZE" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasLockInside_1vFkVHKPjAvvxUxFl0WWv7" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MarkingRodMovementLength_0yycL4CG92IuVgPQIqAk$Z" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumOperatingTime_31nhczYx96JuYbkJ32Ejs4" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MinimumOperatingSpeed_0OpoQ0$Az5huboLE7511z3" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Current_1I1maXboTEcP5x$ShYx_g0" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0S$cEqtVky_yaxVI8p1bfr" Name="Pset_PowerControlSystem" Description="Properties of power control system. The property set can be used by the predefined type ELECTRICAL of IfcDistributionSystem. The property set can be used to characterize the system that controls the railway energy network." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDistributionSystem/ELECTRICAL">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="AssemblyInstruction_3W5i6nbkP9NBt_M6PTB5jW" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0tRUM0qVGHuO00025QrE$V" Name="Pset_PrecastConcreteElementFabrication" Description="Production and manufacturing related properties common to different types of precast concrete elements. The Pset applies to manufactured pieces. It can be used by a number of subtypes of IfcBuiltElement. If the precast concrete ele" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcBeam,IfcBuildingElementProxy,IfcChimney,IfcColumn,IfcFooting,IfcMember,IfcPile,IfcPlate,IfcRamp,IfcRampFlight,IfcRoof,IfcSlab,IfcStair,IfcStairFlight,IfcWall,IfcCivilElement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="TypeDesignation_3_nUqKqXv3xheIJewmELBG" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ProductionLotId_13MQU0qVGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SerialNumber_18jl80qVGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PieceMark_1WZdO0qVGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AsBuiltLocationNumber_1d7Es0qVGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ActualProductionDate_1jgsK0qVGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ActualErectionDate_1oS1a0qVGHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="22X$Y0qVGHuO00025QrE$V" Name="Pset_PrecastConcreteElementGeneral" Description="Production and manufacturing related properties common to different types of precast concrete elements. The Pset can be used by a number of subtypes of IfcBuiltElement. If the precast concrete element is a sandwich wall panel each structural layer or shell represented by an IfcBuildingElementPart may be attached to a separate Pset of this type, if needed. Some of the properties apply only for specific types of precast concrete elements." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcBeam,IfcBuildingElementProxy,IfcChimney,IfcColumn,IfcFooting,IfcMember,IfcPile,IfcPlate,IfcRamp,IfcRampFlight,IfcRoof,IfcSlab,IfcStair,IfcStairFlight,IfcWall,IfcCivilElement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="TypeDesignation_3_nUqKqXv3xheIJewmELBG" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CornerChamfer_2hg8a0qVGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ManufacturingToleranceClass_2qcLg0qVGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FormStrippingStrength_2x9z80qVGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LiftingStrength_31jac0qVGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReleaseStrength_39TUu0qVGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MinimumAllowableSupportLength_3FQyy0qVGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InitialTension_3L_aQ0qVGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TendonRelaxation_3Ry2U0qVGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TransportationStrength_3XJN80qVGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SupportDuringTransportDescription_3dGrC0qVGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SupportDuringTransportDocReference_3jEJG0qVGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HollowCorePlugging_3mD2I0qVGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CamberAtMidspan_3smfm0qVGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BatterAtStart_3xXr00qVGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BatterAtEnd_00v9g0qVKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Twisting_06sdk0qVKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Shortening_0CDyO0qVKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PieceMark_0IBQS0qVKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DesignLocationNumber_0O8uW0qVKHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1wXk3jSczBbAhv5XbwDG7P" Name="Pset_PrecastKerbStone" Description="Properties for precast kerb stone." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcKerb">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalHeight_1Fy4XYaJXDTBDDb9f06ofi" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalLength_07RHK0qUaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TypeDesignation_3_nUqKqXv3xheIJewmELBG" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalWidth_2YZfyYRY1Aa9bsWGvZEaNq" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0g1Ii0qVKHuO00025QrE$V" Name="Pset_PrecastSlab" Description="Layout and component information defining how prestressed slab components are laid out in a precast slab assembly. The values are global defaults for the slab as a whole, but can be overridden by local placements of the individual com" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSlab">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="TypeDesignation_3_nUqKqXv3xheIJewmELBG" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ToppingType_0sYOE0qVKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EdgeDistanceToFirstAxis_0yVsI0qVKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DistanceBetweenComponentAxes_133Tm0qVKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AngleToFirstAxis_1ADEe0qVKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AngleBetweenComponentAxes_1E_Pu0qVKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalThickness_2QgJLpWOb3xfvwr_YO$T_k" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalToppingThickness_1RVVQ0qVKHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2oyf$R5hr3XO6glvM3jFoI" Name="Pset_PreSupportCommon" Description="Properties describing the characteristcs of excavation pre-support measures." ApplicableEntity="IfcBuiltSystem/.TUNNEL_PRESUPPORT.,IfcTunnelTypicalSection/.EXCAVATIONSUPPORT.,IfcElementAssembly/.PRESUPPORTVAULT.,IfcElementAssembly/.PRESUPPORTFACE.">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="PreSupportLocation_2iM5GiTq558OyAc6GsixWz" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UserDefinedPreSupportLocation_31L_rs0AXFXOUbPqj2c38J" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PreSupportType_2ThVWCaSXFCOlQAjGqDSIe" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UserDefinedPreSupportType_2OMwxuX_5ADwNa98rEikYK" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Arrangement_24IjDcPPnCph3L6$aDInL7" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BoreholeLengthPlanned_1_khbjyjf8z9JjevtGbGtr" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BoreholeOverlap_1bTfnQKz18HexhiWS49WG_" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UsefulLength_3CH3oKGNr0XBmhsxbha8gU" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DrillingDiameter_2Fc6nsWWrCKRVtXwxE__CS" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsBoreholeCased_3JVj8MPWf9XRh6qY4yPdAo" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DrillingMethod_2tlZTCJoP5V9xcumCFudxO" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AreHolesGrouted_2pEnnTgZ57F8CFzhnE6a87" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2Lh3q1moHBkf4iGOMmlyvT" Name="Pset_ProcessCapacity" Description="Property set for the application of process data to spatial elements and transport assets" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcBuiltSystem,IfcDistributionSystem,IfcDoor,IfcSpace,IfcTransportationDevice,IfcZone">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ProcessItem_0yXM2dwTn71gpxHeftzb$S" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ProcessCapacity_1lMQMfyaj8WukwZC4nXkfi" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ProcessPerformance_2nqNIMRDj0LAY1mI3ZvbZH" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DownstreamConnections_1FwKNmUX106g_690JTAQck" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UpstreamConnections_0gcm8p7cfF28fgCrHyW9Fj" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1YfGI0qVKHuO00025QrE$V" Name="Pset_ProfileArbitraryDoubleT" Description="This is a collection of geometric properties of double-T section profiles of precast concrete elements, to be used in conjunction with IfcArbitraryClosedProfileDef when profile designation alone does not fulfill the information requirements." ApplicableEntity="IfcArbitraryClosedProfileDef">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="OverallWidth_1fCtm0qVKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LeftFlangeWidth_1mMee0qVKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RightFlangeWidth_1tWPW0qVKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OverallDepth_1_40_0qVKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FlangeDepth_24deS0qVKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FlangeDraft_2Czi80qVKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FlangeChamfer_2IL0o0qVKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FlangeBaseFillet_2OueG0qVKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FlangeTopFillet_2UFyw0qVKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="StemBaseWidth_2ZdHa0qVKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="StemTopWidth_2gAv20qVKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="StemBaseChamfer_2mkWW0qVKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="StemTopChamfer_2s5rA0qVKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="StemBaseFillet_2y3JE0qVKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="StemTopFillet_30qUU0qVKHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="37O5y0qVKHuO00025QrE$V" Name="Pset_ProfileArbitraryHollowCore" Description="This is a collection of geometric properties of hollow core section profiles of precast concrete elements, to be used in conjunction with IfcArbitraryProfileDefWithVoids when profile designation alone does not fulfill the information requirements.

In all cases, the cores are symmetrically distributed on either side of the plank center line, irrespective of whether the number of cores is odd or even. For planks with a center core with different geometry to that of the other cores, provide the property CenterCoreSpacing. When the number of cores is even, no Center Core properties shall be asserted.

Key chamfers and draft chamfer are all 45 degree chamfers.

The CoreTopRadius and CoreBaseRadius parameters can be derived and are therefore not listed in the property set. They are shown to define that the curves are arcs. The parameters for the center core are the same as above, but with the prefix &quot;Center&quot;." ApplicableEntity="IfcArbitraryProfileDefWithVoids">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="OverallWidth_3ClQc0qVKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OverallDepth_3JJ240qVKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EdgeDraft_3QSoy0qVKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DraftBaseOffset_3VD_C0qVKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DraftSideOffset_3Z$9S0qVKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BaseChamfer_3fMU60qVKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="KeyDepth_3k7fM0qVKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="KeyHeight_3ouqc0qVKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="KeyOffset_3tf$s0qVKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BottomCover_3yRB60qVKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoreSpacing_04B5O0qVOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoreBaseHeight_0BKsG0qVOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoreMiddleHeight_0HuTk0qVOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoreTopHeight_0P2Ec0qVOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoreBaseWidth_0WB$U0qVOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoreTopWidth_0clcy0qVOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CenterCoreSpacing_0jvNq0qVOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CenterCoreBaseHeight_0sFRW0qVOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CenterCoreMiddleHeight_0zPCO0qVOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CenterCoreTopHeight_14YzG0qVOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CenterCoreBaseWidth_1Bik80qVOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CenterCoreTopWidth_1JSeQ0qVOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfCores_1QcPI0qVOHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1WZtM0qVOHuO00025QrE$V" Name="Pset_ProfileMechanical" Description="This is a collection of mechanical properties that are applicable to virtually all profile classes. Most of these properties are especially used in structural analysis." ApplicableEntity="IfcProfileDef">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="MassPerLength_1bxC00qVOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CrossSectionArea_1giNG0qVOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Perimeter_1m3hw0qVOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MinimumPlateThickness_1sdJO0qVOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumPlateThickness_20lpI0qVOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CentreOfGravityInX_2AI9o0qVOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CentreOfGravityInY_2I2440qVOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShearCentreZ_2PBqy0qVOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShearCentreY_2VlSQ0qVOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MomentOfInertiaY_2biwU0qVOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MomentOfInertiaZ_2jSqm0qVOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MomentOfInertiaYZ_2rCl20qVOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TorsionalConstantX_2zYok0qVOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WarpingConstant_35usQ0qVOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShearDeformationAreaZ_3G1MK0qVOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShearDeformationAreaY_3NnGc0qVOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumSectionModulusY_3XJd60qVOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MinimumSectionModulusY_3hS700qVOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumSectionModulusZ_3pC1I0qVOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MinimumSectionModulusZ_3vlem0qVOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TorsionalSectionModulus_025iS0qVSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShearAreaZ_0Be2y0qVSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShearAreaY_0KaG20qVSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PlasticShapeFactorY_0TWT80qVSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PlasticShapeFactorZ_0bGNQ0qVSHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3eB6e0UTf3swv6RgjjALlA" Name="Pset_ProjectCommon" Description="Property set for the application of high level project information." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcProject">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ProjectType_2$S70iKB11wRZELFihKhH7" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ProjectInvestmentEstimate_2HOLtVtqH7xBzdXTbAyiun" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FundingSource_2Z2eDnN418DOpcmbgckN0p" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ROI_2LQFM4SPr2lPjRm$a3rQvD" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetEarnedValue_3nJothH31Box8FgRkEz5JD" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PaybackPeriod_0oFyQmlpL9PP5WtBwscQTm" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0lOtK0qVSHuO00025QrE$V" Name="Pset_ProjectOrderChangeOrder" Description="A change order is an instruction to make a change to a product or work being undertake. Note that the change order status is defined in the same way as a work order status since a change order implies a work requirement." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcProjectOrder/CHANGEORDER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReasonForChange_0uxDq0qVSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BudgetSource_12TaK0qVSHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1B$wq0qVSHuO00025QrE$V" Name="Pset_ProjectOrderMaintenanceWorkOrder" Description="A MaintenanceWorkOrder is a detailed description of maintenance work that is to be performed. Note that the Scheduled Frequency property of the maintenance work order is used when the order is required as an instance of a scheduled work order." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcProjectOrder/MAINTENANCEWORKORDER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ProductDescription_1Jlr60qVSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WorkTypeRequested_1S5uo0qVSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ContractualType_1b25u0qVSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IfNotAccomplished_1kaSO0qVSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaintenanceType_1u6ou0qVSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FaultPriorityType_2JXZa0qVSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LocationPriorityType_2e_sC0qVSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ScheduledFrequency_2$eRe0qVSHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="38aek0qVSHuO00025QrE$V" Name="Pset_ProjectOrderMoveOrder" Description="Defines the requirements for move orders. Note that the move order status is defined in the same way as a work order status since a move order implies a work requirement." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcProjectOrder/MOVEORDER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SpecialInstructions_3FkPc0qVSHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3R3CK0qVSHuO00025QrE$V" Name="Pset_ProjectOrderPurchaseOrder" Description="Defines the requirements for purchase orders in a project." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcProjectOrder/PURCHASEORDER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsFOB_3ZPG00qVSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShipMethod_3hlJi0qVSHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3sTz00qVSHuO00025QrE$V" Name="Pset_ProjectOrderWorkOrder" Description="Defines the requirements for purchase orders in a project." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcProjectOrder/WORKORDER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ProductDescription_3_DtI0qVSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WorkTypeRequested_07A4O0qVWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ContractualType_0FW840qVWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IfNotAccomplished_0OSLA0qVWHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0XOYG0qVWHuO00025QrE$V" Name="Pset_PropertyAgreement" Description="A property agreement is an agreement that enables the occupation of a property for a period of time.

The objective is to capture the information within an  agreement that is relevant to a facilities manager. Design and construction information associated with the property is not considered. A property agreement may be applied to an instance of IfcSpatialStructureElement including to compositions defined through the IfcSpatialStructureElement.Element.CompositionEnum.

Note that the associated actors are captured by the IfcOccupant class." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSpatialStructureElement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="AgreementType_0i7Ba0qVWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TrackingIdentifier_16LfS0qVWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AgreementVersion_1GU9M0qVWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AgreementDate_1RCog0qVWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PropertyName_1ZYsM0qVWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CommencementDate_1kHVg0qVWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TerminationDate_1tDim0qVWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Duration_209vs0qVWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Options_27vq80qVWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConditionCommencement_2Gs1E0qVWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Restrictions_2QONk0qVWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConditionTermination_2WLro0qVWHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2hgeW0qVWHuO00025QrE$V" Name="Pset_ProtectiveDeviceBreakerUnitI2TCurve" Description="A coherent set of attributes representing a curve for let-through energy of a protective device. Note - A protective device may be associated with different instances of this pSet providing information related to different basic characteristics" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcProtectiveDevice">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="VoltageLevel_2sPHq0qVWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalCurrent_3Gdli0qVWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BreakerUnitCurve_3PZyo0qVWHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3nPr20qVWHuO00025QrE$V" Name="Pset_ProtectiveDeviceBreakerUnitI2TFuseCurve" Description="A coherent set of attributes representing curves for melting- and breaking-energy of a fuse. Note - A fuse may be associated with different instances of this property set providing information related to different basic characteristics." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcProtectiveDevice">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="VoltageLevel_3tNJ60qVWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BreakerUnitFuseMeltingCurve_0LAfQ0qVaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BreakerUnitFuseBreakingingCurve_0cSwC0qVaHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0t91a0qVaHuO00025QrE$V" Name="Pset_ProtectiveDeviceBreakerUnitIPICurve" Description="A coherent set of attributes representing curves for  let-through currents of a protective device. Note - A protective device may be associated with different instances of this pSet providing information related to different basic characteristics." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcProtectiveDevice">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="VoltageLevel_0z6Ve0qVaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalCurrent_1Vh1C0qVaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BreakerUnitIPICurve_1e14u0qVaHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1x5nu0qVaHuO00025QrE$V" Name="Pset_ProtectiveDeviceBreakerUnitTypeMCB" Description="A coherent set of attributes representing the breaking capacities of an MCB. Note - A protective device may be associated with different instances of this property set providing information related to different basic characteristics." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcProtectiveDevice/CIRCUITBREAKER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="PowerLoss_24e8O0qVaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VoltageLevel_2EmeI0qVaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalCurrents_2kMQq0qVaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ICU60947_2siUW0qVaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ICS60947_30q_Q0qVaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ICN60898_39nBW0qVaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ICS60898_3IjOc0qVaHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3TS1w0qVaHuO00025QrE$V" Name="Pset_ProtectiveDeviceBreakerUnitTypeMotorProtection" Description="A coherent set of attributes representing different capacities of a a motor protection device, defined in accordance with IEC 60947. Note - A protective device may be associated with different instances of this Pset." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcProtectiveDevice">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="PerformanceClasses_3ZPV_0qVaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VoltageLevel_3ixsU0qVaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ICU60947_2siUW0qVaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ICS60947_30q_Q0qVaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ICW60947_0Ktii0qVeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ICM60947_0QF1M0qVeHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2MiXaV5Hj7nfKq7wL9Pojk" Name="Pset_ProtectiveDeviceOccurrence" Description="Properties that are applied to an occurrence of a protective device." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcProtectiveDevice">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="PoleUsage_2a8qh0dWHD9OWx5IdbYOLq" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LongTimeFunction_3v9GlTSDzClwzgroqc5m82" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShortTimeFunction_0pV42acCLEIwfKf4JFHv3g" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShortTimei2tFunction_2h6cR0csPBmv_hfMRK3yFs" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GroundFaultFunction_2ACC9nT6bAfuCPw3yJtgyK" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GroundFaulti2tFunction_015H08Upv8IgOnOdu__Psm" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LongTimeCurrentSetValue_1BmzSXNQn2_Aq_1ft2LPxY" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShortTimeCurrentSetValue_1mgl_HOVb9xhMyLHVK14q_" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InstantaneousCurrentSetValue_0xvitUc492iA3MH7Yy4c1_" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GroundFaultCurrentSetValue_3muRcKEG13Eekov69fIrNH" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LongTimeDelay_3m9GefCtz3PAoplbsg0gtG" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShortTimeTrippingTime_1qouBkrlzAhf_8$b8Y1P5d" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InstantaneousTrippingTime_2NQdbM51T95AtD0w7EUzy_" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GroundFaultTrippingTime_1QKaWg0bX6NwHynHAaPmFn" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0Woeq0qVeHuO00025QrE$V" Name="Pset_ProtectiveDeviceTrippingCurve" Description="Tripping curves are applied to thermal, thermal magnetic or MCB_RCD tripping units (i.e. tripping units having type property sets for thermal, thermal magnetic or MCB_RCD tripping defined). They are not applied to electronic tripping units." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcProtectiveDevice">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="TrippingCurveType_0aNXG0qVeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TrippingCurve_0mITO0qVeHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0$C8Y0qVeHuO00025QrE$V" Name="Pset_ProtectiveDeviceTrippingFunctionGCurve" Description="Tripping functions are applied to electronic tripping units (i.e. tripping units having type property sets for electronic tripping defined). They are not applied to thermal, thermal magnetic or RCD tripping units.
This property set represent the ground fault protection (G-curve) of an electronic protection device" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcProtectiveDeviceTrippingUnit">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsSelectable_12n0_0qVeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalCurrentAdjusted_1AWxG0qVeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ExternalAdjusted_1H4Yk0qVeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReleaseCurrent_1N20o0qVeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReleaseTime_1RpC20qVeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CurrentTolerance1_1Xmg60qVeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CurrentToleranceLimit1_1d7_m0qVeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CurrentTolerance2_1j5Sq0qVeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsCurrentTolerancePositiveOnly_1pf4I0qVeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TimeTolerance1_1wChm0qVeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TimeToleranceLimit1_20A9q0qVeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TimeTolerance2_24xL40qVeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsTimeTolerancePositiveOnly_2Aup80qVeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReleaseCurrentI2tStart_2HSQc0qVeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReleaseTimeI2tStart_2MplG0qVeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReleaseCurrentI2tEnd_2SB3w0qVeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReleaseTimeI2tEnd_2Y8X_0qVeHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2ei9S0qVeHuO00025QrE$V" Name="Pset_ProtectiveDeviceTrippingFunctionICurve" Description="Tripping functions are applied to electronic tripping units (i.e. tripping units having type property sets for electronic tripping defined). They are not applied to thermal, thermal magnetic or RCD tripping units.
This property set represent the instantaneous time protection (I-curve) of an electronic protection device." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcProtectiveDeviceTrippingUnit">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsSelectable_12n0_0qVeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalCurrentAdjusted_2oEVy0qVeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReleaseCurrent_2yM$s0qVeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReleaseTime_32KTw0qVeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CurrentTolerance1_37hoa0qVeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CurrentToleranceLimit1_3G1sG0qVeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CurrentTolerance2_3PaCm0qVeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsCurrentTolerancePositiveOnly_3YWPs0qVeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TimeTolerance1_3eTtw0qVeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TimeToleranceLimit1_3kRL_0qVeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TimeTolerance2_3pCXE0qVeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsTimeTolerancePositiveOnly_3vm8i0qVeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaxAdjustmentX_ICS_3$jcm0qVeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsOffWhenSFunctionOn_2Zqd6j77r7GvBbph7l93Pd" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="06tNe0qViHuO00025QrE$V" Name="Pset_ProtectiveDeviceTrippingFunctionLCurve" Description="Tripping functions are applied to electronic tripping units (i.e. tripping units having type property sets for electronic tripping defined). They are not applied to thermal, thermal magnetic or RCD tripping units.
This property set represent the long time protection (L-curve) of an electronic protection device" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcProtectiveDeviceTrippingUnit">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsSelectable_12n0_0qVeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UpperCurrent1_0Hc0y0qViHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UpperCurrent2_0MzLc0qViHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UpperTime1_0SKgG0qViHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UpperTime2_0Xh_w0qViHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LowerCurrent1_0dfS_0qViHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LowerCurrent2_0kpDs0qViHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LowerTime1_0qmhw0qViHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LowerTime2_0vXtA0qViHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0$VLE0qViHuO00025QrE$V" Name="Pset_ProtectiveDeviceTrippingFunctionSCurve" Description="Tripping functions are applied to electronic tripping units (i.e. tripping units having type property sets for electronic tripping defined). They are not applied to thermal, thermal magnetic or RCD tripping units.
This property set represent the short time protection (S-curve) of an electronic protection device." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcProtectiveDeviceTrippingUnit">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsSelectable_12n0_0qVeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalCurrentAdjusted_191hk0qViHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReleaseCurrent_1FbJC0qViHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReleaseTime_1Kyds0qViHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CurrentTolerance1_1QJyW0qViHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CurrentToleranceLimit1_1VhHA0qViHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CurrentTolerance2_1cr220qViHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsCurrentTolerancePositiveOnly_1jOfW0qViHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TimeTolerance1_1qYQO0qViHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TimeToleranceLimit1_1vvl20qViHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TimeTolerance2_1$tD60qViHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsTimeTolerancePositiveOnly_25qhA0qViHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReleaseCurrentI2tStart_2COIe0qViHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReleaseTimeI2tStart_2Ixw60qViHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReleaseCurrentI2tEnd_2Nj5M0qViHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReleaseTimeI2tEnd_2UGiq0qViHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsOffWhenLfunctionOn_258JATUR56lh3z1MtrEDz$" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2aqKI0qViHuO00025QrE$V" Name="Pset_ProtectiveDeviceTrippingUnitCurrentAdjustment" Description="A set of current adjustment values that may be applied to an electronic or thermal tripping unit type." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcProtectiveDeviceTrippingUnit">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="AdjustmentValueType_2ePCk0qViHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CurrentAdjustmentRange_2mlGQ0qViHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CurrentAdjustmentRangeStepValue_2uVAi0qViHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CurrentAdjustmentValues_2_Sem0qViHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AdjustmentDesignation_34Q6q0qViHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3CA160qViHuO00025QrE$V" Name="Pset_ProtectiveDeviceTrippingUnitTimeAdjustment" Description="A set of time adjustment values that may be applied to an electronic or thermal tripping unit type." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcProtectiveDeviceTrippingUnit">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="AdjustmentValueType_3FkvY0qViHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TimeAdjustmentRange_3O4zE0qViHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TimeAdjustmentRangeStepValue_3VqtW0qViHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TimeAdjustmentValues_3bCCA0qViHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AdjustmentDesignation_3fzNQ0qViHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CurrentForTimeDelay_3mW_u0qViHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="I2TApplicability_3rIA80qViHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="04BrI0qVmHuO00025QrE$V" Name="Pset_ProtectiveDeviceTrippingUnitTypeCommon" Description="Common information concerning tripping units that area associated with protective devices" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcProtectiveDeviceTrippingUnit">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_0EKLC0qVmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Standard_0V0Sa0qVmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UseInDiscrimination_0ba420qVmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AtexVerified_0i7hW0qVmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OldDevice_0o59a0qVmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LimitingTerminalSize_0vEwS0qVmHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="10OhK0qVmHuO00025QrE$V" Name="Pset_ProtectiveDeviceTrippingUnitTypeElectroMagnetic" Description="Information on tripping units that are electrically or magnetically tripped." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcProtectiveDeviceTrippingUnit/ELECTROMAGNETIC">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ElectroMagneticTrippingUnitType_15l$_0qVmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="I1_1LFqY0qVmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="I2_1RDIc0qVmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="T2_1WadG0qVmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DefinedTemperature_1eKXY0qVmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TemperatureFactor_1ku900qVmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="I4_1pfKG0qVmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="I5_1vcoK0qVmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="T5_20APo0qVmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CurveDesignation_24xb20qVmHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2DHek0qVmHuO00025QrE$V" Name="Pset_ProtectiveDeviceTrippingUnitTypeElectronic" Description="Information on tripping units that are electronically tripped." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcProtectiveDeviceTrippingUnit/ELECTRONIC">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ElectronicTrippingUnitType_2IezO0qVmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalCurrents_2Y8ny0qVmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="N_Protection_2fIYq0qVmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="N_Protection_50_2mSJi0qVmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="N_Protection_100_2uoNO0qVmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="N_Protection_Select_2_lrS0qVmHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="36Vlk0qVmHuO00025QrE$V" Name="Pset_ProtectiveDeviceTrippingUnitTypeResidualCurrent" Description="Information on tripping units that are activated by residual current." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcProtectiveDeviceTrippingUnit/RESIDUALCURRENT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="TrippingUnitReleaseCurrent_3BGw_0qVmHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3ULd_0qVmHuO00025QrE$V" Name="Pset_ProtectiveDeviceTrippingUnitTypeThermal" Description="Information on tripping units that are thermally tripped." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcProtectiveDeviceTrippingUnit/THERMAL">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ThermalTrippingUnitType_3Ziye0qVmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="I1_3ocdo0qVmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="I2_3ua5s0qVmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="T2_3zxQW0qVmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DefinedTemperature_03IlA0qVqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TemperatureFactor_09GDE0qVqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CurveDesignation_0E1OU0qVqHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="38hzYSiHmah91JiEvWTGuQ" Name="Pset_ProtectiveDeviceTypeAntiArcingDevice" Description="Anti arcing device properties used in energy domain. The property set can be used by the predefined type ANTI_ARCING_DEVICE of IfcProtectiveDevice." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcProtectiveDevice/ANTI_ARCING_DEVICE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="RatedVoltage_0_oie0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GroundingType_0GRwj6SjTAtwY3611gVZUL" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0Mzba0qVqHuO00025QrE$V" Name="Pset_ProtectiveDeviceTypeCircuitBreaker" Description="A coherent set of attributes representing different capacities of a circuit breaker or of a motor protection device, defined in accordance with IEC 60947. Note - A protective device may be associated with different instances of this property set providing information related to different basic characteristics." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcProtectiveDevice/CIRCUITBREAKER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="PerformanceClasses_0Rkmq0qVqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VoltageLevel_0YuXi0qVqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ICU60947_2siUW0qVaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ICS60947_30q_Q0qVaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ICW60947_10hu00qVqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ICM60947_17reu0qVqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfPhases_1BIplyxBLFfuml0KvHZ1y2" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1EPGM0qVqHuO00025QrE$V" Name="Pset_ProtectiveDeviceTypeCommon" Description="Properties that are applied to a definition of a protective device." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcProtectiveDevice">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_1OXmG0qVqHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3poBpe7Yb6C8CjOhgExNd4" Name="Pset_ProtectiveDeviceTypeEarthingSwitch" Description="Properties for protective devices of type EARTHINGSWITCH." ApplicableEntity="IfcProtectiveDevice/EARTHINGSWITCH">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfPhases_1BIplyxBLFfuml0KvHZ1y2" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3Ba7g0qVqHuO00025QrE$V" Name="Pset_ProtectiveDeviceTypeEarthLeakageCircuitBreaker" Description="An earth failure device acts to protect people and equipment from the effects of current leakage." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcProtectiveDevice/EARTHLEAKAGECIRCUITBREAKER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="EarthFailureDeviceType_3GLIw0qVqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Sensitivity_3c_uM0qVqHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3k8fE0qVqHuO00025QrE$V" Name="Pset_ProtectiveDeviceTypeFuseDisconnector" Description="A coherent set of attributes representing the breaking capacity of a fuse, defined in accordance with IEC 60269. Note - A protective device may be associated with different instances of this pSet providing information related to different basic characteristics." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcProtectiveDevice/FUSEDISCONNECTOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="FuseDisconnectorType_3pVzu0qVqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VoltageLevel_0jKEI0qVuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IC60269_0$onu0qVuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PowerLoss_15mFy0qVuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfPhases_1BIplyxBLFfuml0KvHZ1y2" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReferenceEnvironmentTemperature_2vgOshA4D0$ems5HSBwemr" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BreakingCapacity_0SRRZKplf9oAKBz3w0a2po" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ArcExtinctionType_1iKRDrl9j6IQuyzsIknVc2" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfPoles_2lqxx3IET2UhUPt$MJGW_4" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TransformationRatio_0z_ZR$vVrEivWXuanAlBNq" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalFrequency_0rcYS0qU0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalCurrent_0sDhk0qUWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RatedVoltage_1uw9k0qSWHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1DWAE0qVuHuO00025QrE$V" Name="Pset_ProtectiveDeviceTypeResidualCurrentCircuitBreaker" Description="A residual current circuit breaker opens, closes or isolates a circuit and has short circuit and overload protection." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcProtectiveDevice/RESIDUALCURRENTCIRCUITBREAKER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Sensitivity_1IHLU0qVuHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1PR6M0qVuHuO00025QrE$V" Name="Pset_ProtectiveDeviceTypeResidualCurrentSwitch" Description="A residual current switch opens, closes or isolates a circuit and has no short circuit or overload protection." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcProtectiveDevice/RESIDUALCURRENTSWITCH">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Sensitivity_1IHLU0qVuHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2wID0hgH9lQvUFSh$dmt0E" Name="Pset_ProtectiveDeviceTypeSparkGap" Description="Spark gap properties used in energy domain. The property set can be used by the predefined type SPARKGAP and VOLTAGELIMITER of IfcProtectiveDevice." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcProtectiveDevice/VOLTAGELIMITER,IfcProtectiveDevice/SPARKGAP">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="BreakdownVoltageTolerance_36oHQCC0b0jubTadGmGjOS" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Capacitance_05ATmeM_P3vvDHn98$$8$7" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CurrentRMS_0Y55X3X$b2LR4CS5G0nLXs" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PowerDissipation_3UBu01JHrASAEoqzhOMsSb" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SparkGapType_2yd82GST551f428rzb7p5q" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Resistivity_0CD1$azajCjeK721qDipOz" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1byBu0qVuHuO00025QrE$V" Name="Pset_ProtectiveDeviceTypeVaristor" Description="A high voltage surge protection device." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcProtectiveDevice/VARISTOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="VaristorType_1hJWY0qVuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CharacteristicFunction_3k9Awz48fCZAHkVCckwD67" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1bOGrr1FjA$fn5g6I$4Tdb" Name="Pset_ProvisionForVoid" Description="Properties for Provisions For Voids." ApplicableEntity="IfcBuildingElementProxy/PROVISIONFORVOID,IfcVirtualElement/PROVISIONFORVOID">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="VoidShape_1H0k$LSmzANucAEmnKbfql" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Width_3jZbKSm1T9JwAjrhRilc2T" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Height_3leRmD4gzEdRgnDuLoYX91" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Diameter_0XZt0PbcT8NePFqS$CxwYx" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Depth_0jbWAM7Tb3LB2Zw79LWTzY" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="System_0aojTM4Y5Fru_D_RsVHF_N" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1uQlU0qVuHuO00025QrE$V" Name="Pset_PumpOccurrence" Description="Pump occurrence attributes attached to an instance of IfcPump." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcPump">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ImpellerDiameter_1zo480qVuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BaseType_25X_Q0qVuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DriveConnectionType_2IfDM0qVuHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2XYuW0qVuHuO00025QrE$V" Name="Pset_PumpPHistory" Description="Pump performance history attributes." TemplateType="pset_performancedriven" ApplicableEntity="IfcPump">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="MechanicalEfficiency_2cK3m0qVuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OverallEfficiency_2fuyC0qVuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PressureRise_2jTqe0qVuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RotationSpeed_2mSZg0qVuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Flowrate_2pRIi0qVuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PowerHistory_2sQ1k0qVuHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2v_wA0qVuHuO00025QrE$V" Name="Pset_PumpTypeCommon" Description="Common attributes of a pump type." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcPump">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_36V$i0qVuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FlowRateRange_3KpXS0qVuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FlowResistanceRange_3RzIK0qVuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConnectionSize_3chxe0qVuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TemperatureRange_3jriW0qVuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetPositiveSuctionHead_3rbco0qVuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalRotationSpeed_3xZ4s0qVuHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2$PrvgGFj6DR2nBF7t$AJB" Name="Pset_QuayCommon" Description="Properties common to the definition of all occurrences of _IfcMarineFacility_ with the predefined type set to QUAY." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcMarineFacility/QUAY">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="StructuralType_0cKUD5vlD8$g5oDvXR_9FO" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BentSpacing_3luyrgW5f2MfRaz4L28ggQ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="QuaySectionType_1NgIfYZRT9j8NN6lJ2fnxX" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Elevation_2CNMMPOkjA69oPOt9bGTaw" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1Z7rzyZOD0hRI6ztDJmZrQ" Name="Pset_QuayDesignCriteria" Description="Properties common to the definition of design criteria of all occurrences of _IfcMarineFacility_ with the predefined type set to QUAY." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcMarineFacility/QUAY">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="HighWaterLevel_0S3mSsoqT9xvSAc$Cv67oe" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LowWaterLevel_2CX_WFHkv9vByq2fOmXUgW" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ExtremeHighWaterLevel_3GFn0Pp5r0eQGPHYahYbQS" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ExtremeLowWaterLevel_2BQGedM913bgYQyPz49FRV" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShipLoading_1QIfuyRDnEaQu6kbYym8p3" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WaveLoading_3ixoBF$s5EUxf3ONHSALX6" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FlowLoading_1N4dPw9IT6AvWCtPogKQA_" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UniformlyDistributedLoad_2oFKKjPUb4bA5i8GWGN0uJ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EquipmentLoading_1e0Ns0$oTF1RHtc3O5zTbg" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3arxBn$e535vzOOfu89SBa" Name="Pset_RadiiKerbStone" Description="Properties describing the keb stone radii." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcKerb">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="CurveShape_3O7zTf47TB3hWv3KJi7PR5" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Radius_2591D4Lin3Jhrrps1RS0JX" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="00KG60qVyHuO00025QrE$V" Name="Pset_RailingCommon" Description="Properties common to the definition of all occurrences of IfcRailing." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcRailing">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_0DRV20qVyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Height_0PMRA0qVyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Diameter_0Vw2e0qVyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsExternal_0d3pW0qVyHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2lK9j_ZKxobB3CkpIN_1Mc" Name="Pset_RailTypeBlade" Description="Properties common to IfcRail types and occurrences with PredefinedType set to BLADE." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcRail/BLADE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsArticulatedBlade_3_6yRUpZDBOvmNhnWeL_XS" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsFallbackBlade_0mvKptGVb02xCOJPjqgmF6" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalLength_07RHK0qUaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BladeRadius_2ofuc3Up1869TEaeM_5Uhn" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0Yg30qx4H1MhNz5GdJFPe0" Name="Pset_RailTypeCheckRail" Description="Properties common to IfcRail types and occurrences with PredefinedType set to CHECKRAIL." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcRail/CHECKRAIL">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="CheckRailType_2JexmLPDX5sBsONo7e2qsk" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InstallationPlan_2beGsManD6zPMmBIW4LY_Q" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3rY35$aq6t5YcPB5UZ7PAY" Name="Pset_RailTypeGuardRail" Description="Properties common to IfcRail types and occurrences with PredefinedType set to GUARDRAIL." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcRail/GUARDRAIL">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GuardRailConnection_1e7Nb8No96yQH99WQ23C68" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PositionInTrack_2$JKUv68rC$QfoodxwEHNq" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GuardRailType_2pyysGb8D26hJVn4mkBF6i" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3K4YmWA90aOt6b9RlYlRTy" Name="Pset_RailTypeRail" Description="Properties common to IfcRail types and occurrences with PredefinedType set to RAIL." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcRail/RAIL">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="PositionInTrack_2$JKUv68rC$QfoodxwEHNq" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TechnicalStandard_2M$Q1oBlHFBhUArnmHLc4W" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RailDeliveryState_36$bpzasz7Wwt383_gPDf3" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RailCondition_1GKMqOWo538xJ6QcnnKJnb" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DrillOnRail_2ut2HorsvEPgzgSM02FBVT" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RailElementaryLength_139zI2nWv5vuRYYFkrBt5t" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MinimumTensileStrength_1BfGlztTjDKfKH4_hnz50p" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsStainless_3o8$Mm6_13vB7BMsiZ5H6c" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InstallationPlan_2beGsManD6zPMmBIW4LY_Q" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1wYjuRg9HEFDexQwflfZNd" Name="Pset_RailTypeStockRail" Description="Properties common to IfcRail types and occurrences with PredefinedType set to STOCKRAIL." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcRail/STOCKRAIL">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="StockRailRadius_1GaLKhaGH1$x4YploezUeu" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InstallationPlan_2beGsManD6zPMmBIW4LY_Q" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalLength_07RHK0qUaHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0DuBuFsLbhFEecCeXGV$De" Name="Pset_RailwayBalise" Description="Properties applicable to a railway balise. This property set is applied to a type or occurrence of _IfcCommunicationsAppliance_ with predefined type TRANSPONDER." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCommunicationsAppliance/TRANSPONDER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalHeight_1Fy4XYaJXDTBDDb9f06ofi" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalWidth_2YZfyYRY1Aa9bsWGvZEaNq" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalWeight_1NkoWVgmHA5xrENqUppTds" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalLength_07RHK0qUaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FailureInformation_30Y_YD1x1DY8_4MwqYT1kM" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RailwayBaliseType_0vpUHwHvz9kAU_7eMQONr9" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DetectionRange_18tiQnmqr3a9LRMZ$sdhle" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InformationLength_05Ecr739L7IvyGuZ7C$2zv" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TransmissionRate_16aHHnGsH6whp$VLYqdzOc" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OperationalTemperatureRange_2_eMO0qS0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IP_Code_1MhaW0qTyHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1AMakB2DjgHfu1MD_bQNOx" Name="Pset_RailwayCableCarrier" Description="Common properties for cable carrier segments constructed in railway projects." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcCableCarrierSegment">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfCrossedTracks_31ax3izS5EHwlYbat3DlDq" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1$L7_HRT0M79Wa7s2Drc3P" Name="Pset_RailwayLevelCrossing" Description="Properties appliable to _IfcFacilityPartCommon_ with PredefinedType set to LEVELCROSSING." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcFacilityPartCommon/LEVELCROSSING">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsAccessibleByVehicle_3R5N45JWj9UumSu_fUKeWz" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasDrainage_30Z3LZrU15p9CBV6oSf4at" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsPrivateOwner_1E7ZEm8I13sg3M3fKSTa3V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PermissibleRoadLoad_0dZw4UYSDFVPrQibCUZruL" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsSecuredBySignalingSystem_3lKpC5tQT9EP06pEGEuocd" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsExceptionalTransportRoute_1UpphLsIf8AQz1eoTOneG9" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2JdA5pTzAkvQsC0gPimYoP" Name="Pset_RailwaySignalAspect" Description="Properties in this property set are applicable for _IfcSignal_ and _IfcSign_ applied in railways. These properties describe the signal aspect, which is the information on the signal or sign shown to the train driver." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSignal,IfcSign">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Symbol_1e6VoJKif46hPnVSUT$o5u" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AppliesToTrainCategory_3oA0EztgbEguYGMhtbbFi2" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SignalAspectType_0E2G9ROg95xwoP5_z_Eeii" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SignLegend_0eTw1IH6j7MugyK0Ib18nX" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3KOFA7iV6l0gT2EY8PRA7y" Name="Pset_RailwaySignalOccurrence" Description="Properties common to the definition of occurrences of _IfcSignal_ applied in railways." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcSignal">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ApproachSpeed_2khyDboNP4W87sfeq3cm4L" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HandSignallingProhibited_2MtpmLU05CZvLEmhti1SE7" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LimitedClearances_1TH9KclvbAF8FOnAfemrVO" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfLampsNotUsed_0_13cp55j8ePtD_qiEfHkv" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RequiresOLEMesh_2lR_SlvAbENQL3ZSWl6HTj" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RequiresSafetyHandrail_1nZR15WS156fFW_vfybVP0" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SignalPostTelephoneID_0NCWcMrUb2H8fwqgBRgcB0" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SignalPostTelephoneType_0TSpUzg5H3AAZB2WOvWebT" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SpecialPositionArrangement_1eejWaX7j3auMW_oHyVPWg" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HinderingObstaclesDescription_2$H1tVSRb5I9MS8oseNlm7" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SignalWalkwayLength_2hoc6PPhvELAtWTUyKoQU6" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RequiresBannerSignal_2cBDBcV2H8HvKswkpaUxpJ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DistanceToStopMark_3PTovWBffA9x2Weil3WJ5t" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1sIqbSmtCwVJvVCk4s8hE1" Name="Pset_RailwaySignalSighting" Description="Properties that define information about signal sighting or visibility in railways. These properties are applicable to occurrences of _IfcSignal_ and _IfcSign_." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcSignal,IfcSign">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SignalSightingAchievableDistance_1NvUvG1d5BFRrtpV4UnXSI" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SignalSightingAvailableDistance_37LmZXPG56MQ4d$oQFgCw0" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SignalSightingCombinedWithRepeater_1xuTh0Z$T9uAGTWtHgVFHl" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SignalSightingMinimum_1oooHdNF9CLwBYFzw5Mlls" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SignalSightingPreferred_3$$GnFzi98gvjNQK5FSUFz" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SignalSightingRouteIndicator_1UzmZKZgT3_egnwLmHjJWR" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SignalViewingMinimumInFront_2bEP3oC5z3WBxX9H7BsKu5" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1z0VlGfyup5NjFUaN_TsoD" Name="Pset_RailwaySignalType" Description="Properties common to the definition of occurrences and types of _IfcSignal_ applied in railways." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSignal">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SignalIndicatorType_0Shkb4IIr0WOC35qEoq_UO" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LensDiffuserType_0HtZMlqZj0fx$DPfT30e_r" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasConductorRailGuardBoard_3mwIKc7vTChu5cFjTlAuyB" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumDisplayDistance_1w3RnQrv17Lg3BEC7BotnA" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RequiredDisplayDistance_36D8aP$xH6CecE2OoCc7Dx" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsHighType_1mNsJbl7z7nRsPj_JQtlc5" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SignalHoodLength_0V5henCzj7ouBew9_bcs0i" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HotStripOrientation_3feSaKbt1E2xMLDm8EVzJQ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LensDiffuserOrientation_17lLkbAkr2TPS5BNTPqqUI" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfLamps_29tB4ms5f55RLnGgTQOHCX" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SignalMessage_0tVDoRl1v74RpBVl3MpeD6" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RailwaySignalType_3pasYELxHFsBeUBXC9tocZ" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="016IF1_$A4_M8Lu_f3okl9" Name="Pset_RailwayTrackStructurePart" Description="Properties applicable to _IfcRailwayPart_ with PredefinedType set to TRACK, or more specialized types including PLAINTRACK, TURNOUTTRACK, DILATATIONTRACK or TRACKPART." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcRailwayPart/DILATIONTRACK,IfcRailwayPart/PLAINTRACK,IfcRailwayPart/TRACK,IfcRailwayPart/TURNOUTTRACK,IfcRailwayPart/TRACKPART)">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasBallastTrack_3GWQlZqZbCOhyZObZZzqs$" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasCWR_1mrqmXkov0pfRjK0zoCDrB" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsSunExposed_3jUxqj7iX3zerVO_VEXgG7" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TrackSupportingStructure_0HyLCL3Pz3kwIHGXDrwFlL" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0j1Ha0qVyHuO00025QrE$V" Name="Pset_RampCommon" Description="Properties common to the definition of all occurrences of IfcRamp." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcRamp">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_0uyDi0qVyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RequiredHeadroom_15TJE0qVyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RequiredSlope_1C0wi0qVyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HandicapAccessible_1Wu3w0qVyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasNonSkidSurface_1cFOa0qVyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FireExit_1RWlG0qVyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsExternal_1GByY0qVyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ThermalTransmittance_3MLW9Uqir2HPZ8iRLwgUEW" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LoadBearing_1s7fxao7L4X9mgLw5vDLbk" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FireRating_1LZHC0qVyHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1ip020qVyHuO00025QrE$V" Name="Pset_RampFlightCommon" Description="Properties common to the definition of all occurrences of IfcRampFlight." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcRampFlight">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_1ujyA0qVyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Headroom_25F1i0qVyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ClearWidth_2BofA0qVyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Slope_2IMGe0qVyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CounterSlope_2N7Ru0qVyHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0mINmUaX1AXhkwsBxEhqix" Name="Pset_ReferentCommon" Description="Specifies common properties for _IfcReferent_" TemplateType="pset_occurrencedriven" ApplicableEntity="IfcReferent">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NameFormat_0GYqVYWxT8AgvoGFCd4ZW3" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2T4vy0qVyHuO00025QrE$V" Name="Pset_ReinforcementBarCountOfIndependentFooting" Description="Reinforcement Concrete parameter [ST-2]: The amount number information of reinforcement  bar with the independent footing. The X and Y direction are based on the local coordinate system of building storey. The X and Y direction of the reinforcement bar are parallel to the X and Y axis of the IfcBuildingStorey&apos;s local coordinate system, respectively." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcFooting">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Description_2W3e_0qVyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_2aqqE0qVyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="XDirectionLowerBarCount_2goII0qVyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YDirectionLowerBarCount_2lZTY0qVyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="XDirectionUpperBarCount_2qKeo0qVyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YDirectionUpperBarCount_2v5q20qVyHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="30Faw0qVyHuO00025QrE$V" Name="Pset_ReinforcementBarPitchOfBeam" Description="The pitch length information of reinforcement bar with the beam." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcBeam">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Description_2W3e_0qVyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_3BaNe0qVyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="StirrupBarPitch_3JKHw0qVyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SpacingBarPitch_3PtvO0qVyHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3YDz40qVyHuO00025QrE$V" Name="Pset_ReinforcementBarPitchOfColumn" Description="The pitch length information of reinforcement  bar with the column. The X and Y direction are based on the local coordinate system of building storey. The X and Y direction of the reinforcement bar are parallel to the X and Y axis of the IfcBuildingStorey&apos;s local coordinate system, respectively." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcColumn">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Description_2W3e_0qVyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_3iycO0qVyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReinforcementBarType_3rIg40qVyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HoopBarPitch_01DcC0qW0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="XDirectionTieHoopBarPitch_08NN40qW0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="XDirectionTieHoopCount_0G7HM0qW0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YDirectionTieHoopBarPitch_0KuSc0qW0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="YDirectionTieHoopCount_0SeMu0qW0HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0Ybqy0qW0HuO00025QrE$V" Name="Pset_ReinforcementBarPitchOfContinuousFooting" Description="Reinforcement Concrete parameter [ST-2]: The pitch length information of reinforcement bar with the continuous footing." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcFooting">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Description_2W3e_0qVyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_0hY220qW0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CrossingUpperBarPitch_0o5fW0qW0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CrossingLowerBarPitch_0vrZo0qW0HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="12BdU0qW0HuO00025QrE$V" Name="Pset_ReinforcementBarPitchOfSlab" Description="The pitch length information of reinforcement bar with the slab." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSlab">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Description_2W3e_0qVyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_1Eij00qW0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LongOutsideTopBarPitch_1LGKU0qW0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LongInsideCenterTopBarPitch_1TcOA0qW0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LongInsideEndTopBarPitch_1byRs0qW0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShortOutsideTopBarPitch_1kIVY0qW0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShortInsideCenterTopBarPitch_1rSGQ0qW0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShortInsideEndTopBarPitch_1zoK60qW0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LongOutsideLowerBarPitch_25YEO0qW0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LongInsideCenterLowerBarPitch_2DuI40qW0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LongInsideEndLowerBarPitch_2LeCM0qW0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShortOutsideLowerBarPitch_2SnzE0qW0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShortInsideCenterLowerBarPitch_2b80w0qW0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShortInsideEndLowerBarPitch_2itxC0qW0HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2sQHi0qW0HuO00025QrE$V" Name="Pset_ReinforcementBarPitchOfWall" Description="The pitch length information of reinforcement bar with the wall." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcWall">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Description_2W3e_0qVyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_31l4Q0qW0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BarAllocationType_38Ihu0qW0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VerticalBarPitch_3McDe0qW0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HorizontalBarPitch_3UM7w0qW0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SpacingBarPitch_3dIL00qW0HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3ZXiv4rqP5jO7RlV21py_O" Name="Pset_ReinforcingMeshCommon" Description="Common properties for reinforcing meshes." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcReinforcingMesh">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="AreaDensity_2zXs$B2Bz2kxUwiWQyK1Os" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CorrosionTreatment_3tiPdiQHXE1RcerDmwYVRN" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfMeshLayers_1xLpRzB018EhsaurxTR7CZ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OverlapLength_0vkCsg8vPFQRRT1mu2QiL9" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0BZb1D1$DC0OVlYbLhxID0" Name="Pset_ReinforcingMeshTypeSteelStraps" Description="Properties related to reinforcing meshes of type STEELSTRAPS." ApplicableEntity="IfcReinforcingMesh/STEELSTRAPS">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="CorrosionTreatment_3tiPdiQHXE1RcerDmwYVRN" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BoltType_1hXaGNY9PBI8lNN9k3njm_" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BoltLength_3qco31$wb0lR1QsW$CJbYv" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="06bLLo7i963w9BQKYrtFZ3" Name="Pset_RepairOccurrence" Description="Properties defining repair information for occurrences of element, asset or system." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcElement,IfcAsset,IfcSystem">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="RepairContent_2uB5y1E3H1zuDscjqI6Rjw" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RepairDate_1fKpvOEozEKQHboTTf4_f7" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MeanTimeToRepair_3wO8ns0az0euk3DIe06ndR" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2vTielYHz0ahKZgQPjtT$Z" Name="Pset_RevetmentCommon" Description="Properties common to the definition of all occurrences of _IfcMarineFacility_ with the predefined type set to REVETMENT." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcMarineFacility/REVETMENT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="StructuralType_0cKUD5vlD8$g5oDvXR_9FO" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Elevation_2CNMMPOkjA69oPOt9bGTaw" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2HuDtqrhf5uxQ9eGKGllIy" Name="Pset_Risk" Description="An indication of exposure to mischance, peril, menace, hazard or loss. Documentation of a potential hazard, likelihood and consequence aligned with AS/NZS 4360 and BS PAS 1192-6:2017, which can be assigned to or associated with a product, activity and/or location. Alternatively it may be assigned to an ISO 3864 annotation symbol.

&amp;gt; HISTORY: Extended in IFC2x3, Revised IFC4x3 

There are various types of risk that may be encountered and there may be several instances of Pset_Risk associated to an instance or type." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcProcess,IfcProduct,IfcGroup">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="RiskName_0gOQsqV_bA4gUGjAMYalbC" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RiskType_1JPHxf_1r6Ggkz9sLX8cSQ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NatureOfRisk_0OyiwhoKjEQwHSx5sV_eCt" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RiskAssessmentMethodology_09ClN62Hr79h3URe8omgR9" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UnmitigatedRiskLikelihood_1Mb3$S0h15Vue$TBwV26oa" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UnmitigatedRiskConsequence_1t9ADGHCfFUQZuSCWzXhY3" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UnmitigatedRiskSignificance_0e40TDcGfEt9qzhUbiDnYC" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MitigationPlanned_1qnDxn1uP53Og8CTc_unk3" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MitigatedRiskLikelihood_2mh3cZyunB0ONymM2LqXn$" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MitigatedRiskConsequence_2FMrp8g1P97QhZQC8NiD8G" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MitigatedRiskSignificance_3aZMkhheX3pPXI0xXDCzn0" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MitigationProposed_0AFQA2rm9398mY_MHHcg3U" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AssociatedProduct_139f3ZZq14mvqATf6iPSJ3" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AssociatedActivity_2AF5ccxkDDlOGOFWk7ITai" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AssociatedLocation_0KVR2PgJn4_ublMgB8xxwD" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0y66J7RfL6nwKlNjkcU$$x" Name="Pset_RoadDesignCriteriaCommon" Description="Road design criteria that may be attached to road parts." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcRoad,IfcFacilityPartCommon/JUNCTION,IfcFacilityPartCommon/LEVELCROSSING,IfcFacilityPartCommon/SEGMENT,IfcRoadPart/BICYCLECROSSING,IfcRoadPart/INTERSECTION,IfcRoadPart/PEDESTRIAN_CROSSING,IfcRoadPart/RAILWAYCROSSING,IfcRoadPart/ROADSEGMENT,IfcRoadPart/ROUNDABOUT,IfcRoadPart/TOLLPLAZA">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Crossfall_2r4dJd_Ib7vAwA1J9WH9sP" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DesignSpeed_1RucFnS_DA08gMyxFgMMmy" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DesignTrafficVolume_3$JqqoXBrCmxu$2E6ICdj4" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DesignVehicleClass_2J5aej9g10suuFcIr2MMKA" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LaneWidth_0YC67HdNT54ulouz_nXO0L" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfThroughLanes_0V8hbusFnFk9GtjJUPdbt4" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RoadDesignClass_22loa_egPD6AlK4tbbeF4d" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3277xykfH0LQcfBXCPuN$4" Name="Pset_RoadGuardElement" Description="Properties assigned to IfcWall/PARAPET or IfcRailing/GUARDRAIL when assigned as road guard elements." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcRailing/GUARDRAIL,IfcWall/PARAPET">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsMoveable_2PCpjtVLvAUPco$vP4wWML" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsTerminal_0Wg6oF21T7uegGAdhCCMvp" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsTransition_3NMOg9ojPFzfUPLZ8yR9b$" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TerminalType_39wtrejBf7PuCumwJUl9Gt" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3X082r2yn5Eh8mN7Blu9_q" Name="Pset_RoadMarkingCommon" Description="Properties for road markings." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcSurfaceFeature/HATCHMARKING,IfcSurfaceFeature/LINEMARKING,IfcSurfaceFeature/PAVEMENTSURFACEMARKING,IfcSurfaceFeature/SYMBOLMARKING">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ApplicationMethod_3weM9ZLs9A9wkW7_awRCSv" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DiagramNumber_3wqbOd6ljDowCHqDXD8raW" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaterialColour_3yAyxI68v5rR3KlzC79inK" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaterialThickness_2isecb3j59shOn6YU4eVwC" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaterialType_1lAU4TV650ghJ4XdGFiLnC" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Structure_2kWG3nIaXA$fxaD3w_yfmG" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0RwgBcfA5D5AB7kcKUQwx6" Name="Pset_RoadSymbolsCommon" Description="Properties for road symbols." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcSurfaceFeature/SYMBOLMARKING">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Text_3hqugetTP6y8gQM8yBm9Ml" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TypeDesignation_3_nUqKqXv3xheIJewmELBG" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2Ga4O0qW4HuO00025QrE$V" Name="Pset_RoofCommon" Description="Properties common to the definition of all occurrences of IfcRoof. Note: Properties for ProjectedArea and TotalArea added in IFC 2x3" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcRoof">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_2UHSk0qW4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AcousticRating_2jnHI0qW4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsExternal_2zH5s0qW4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ThermalTransmittance_34Qsk0qW4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LoadBearing_27gGzXJgHElgJNKZaas8aH" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FireRating_2rXBa0qW4HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3AOKo0qW4HuO00025QrE$V" Name="Pset_SanitaryTerminalTypeBath" Description="Sanitary appliance for immersion of the human body or parts of it (BS6100). HISTORY: In IFC4, Material and MaterialThickness properties removed. Use materials capabilities from IfcMaterialResource schema. Datatype of color changed to IfcLabel (still a string value)" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSanitaryTerminal/BATH">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="BathType_3GLos0qW4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DrainSize_0FXNw0qW8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasGrabHandles_0NHIC0qW8HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0UR340qW8HuO00025QrE$V" Name="Pset_SanitaryTerminalTypeBidet" Description="Waste water appliance for washing the excretory organs while sitting astride the bowl (BS6100). HISTORY: In IFC4, Material property removed. Use materials capabilities from IfcMaterialResource schema. Datatype of color changed to IfcLabel (still a string value). BidetMounting changed to Mounting." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSanitaryTerminal/BIDET">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Mounting_0ZoNk0qW8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SpilloverLevel_1JU8E0qW8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DrainSize_1RqBw0qW8HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1amP00qW8HuO00025QrE$V" Name="Pset_SanitaryTerminalTypeCistern" Description="A water storage unit attached to a sanitary terminal that is fitted with a device, operated automatically or by the user, that discharges water to cleanse a water closet (toilet) pan, urinal or slop hopper. (BS6100 330 5008)" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSanitaryTerminal/CISTERN">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="CisternHeight_1g7jg0qW8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CisternCapacity_1uRFQ0qW8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsSingleFlush_1zoa40qW8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FlushType_24yKy0qW8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FlushRate_2LeSK0qW8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsAutomaticFlush_2SoDC0qW8HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2gVbY0qW8HuO00025QrE$V" Name="Pset_SanitaryTerminalTypeCommon" Description="Common properties for sanitary terminals." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSanitaryTerminal">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_0R776yD1b15fWhkijME2BM" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalLength_0NS18P1J51kRFniH3h5CIL" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalWidth_2YZfyYRY1Aa9bsWGvZEaNq" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalDepth_0HZnE0qUaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Colour_2J4I2LAOv4qfhgUPNOBh82" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2rqOG0qW8HuO00025QrE$V" Name="Pset_SanitaryTerminalTypeSanitaryFountain" Description="A sanitary terminal that provides a low pressure jet of water for a specific purpose (IAI). HISTORY: In IFC4, Material property removed. Use materials capabilities from IfcMaterialResource schema. Datatype of color changed to IfcLabel (still a string value)." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSanitaryTerminal/SANITARYFOUNTAIN">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="FountainType_2xBiw0qW8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Mounting_0ZoNk0qW8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DrainSize_3uarm0qW8HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="027CG0qWCHuO00025QrE$V" Name="Pset_SanitaryTerminalTypeShower" Description="Installation or waste water appliance that emits a spray of water to wash the human body (BS6100). HISTORY: In IFC4, Material and MaterialThickness properties removed. Use materials capabilities from IfcMaterialResource schema. Datatype of color changed to IfcLabel (still a string value)" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSanitaryTerminal/SHOWER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShowerType_06uNW0qWCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasTray_0Lo2g0qWCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShowerHeadDescription_0xxSg0qWCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DrainSize_12V480qWCHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1Ar7q0qWCHuO00025QrE$V" Name="Pset_SanitaryTerminalTypeSink" Description="Waste water appliance for receiving, retaining or disposing of domestic, culinary, laboratory or industrial process liquids. HISTORY: In IFC4, Material property removed. Use materials capabilities from IfcMaterialResource schema. Datatype of color changed to IfcLabel (still a string value). SinkMounting changed to Mounting." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSanitaryTerminal/SINK">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SinkType_1JBBW0qWCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Mounting_0ZoNk0qW8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Colour_2J4I2LAOv4qfhgUPNOBh82" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DrainSize_2y5300qWCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MountingOffset_351G60qWCHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3CnAO0qWCHuO00025QrE$V" Name="Pset_SanitaryTerminalTypeToiletPan" Description="Soil appliance for the disposal of excrement. HISTORY: In IFC4, Material property removed. Use materials capabilities from IfcMaterialResource schema. Prefix for color property removed. Datatype of color changed to IfcLabel (still a string value)." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSanitaryTerminal/TOILETPAN">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ToiletType_3I8V20qWCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ToiletPanType_3dbng0qWCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PanMounting_3thle0qWCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SpilloverLevel_0FXdu0qWGHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0mJjE0qWGHuO00025QrE$V" Name="Pset_SanitaryTerminalTypeUrinal" Description="Soil appliance that receives urine and directs it to a waste outlet (BS6100). HISTORY: In IFC4, Material property removed. Use materials capabilities from IfcMaterialResource schema. Prefix for color property removed. Datatype of color changed to IfcLabel (still a string value). Mounting property added." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSanitaryTerminal/URINAL">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="UrinalType_0r4uU0qWGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Mounting_0ZoNk0qW8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SpilloverLevel_1PRsG0qWGHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1wq500qWGHuO00025QrE$V" Name="Pset_SanitaryTerminalTypeWashHandBasin" Description="Waste water appliance for washing the upper parts of the body. HISTORY: In IFC4, Material property removed. Use materials capabilities from IfcMaterialResource schema. Datatype of color changed to IfcLabel (still a string value)." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSanitaryTerminal/WASHHANDBASIN">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="WashHandBasinType_20BPg0qWGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Mounting_0ZoNk0qW8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DrainSize_2$z880qWGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MountingOffset_39VUe0qWGHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1go2QzEJBD3SEpbnrFENZO" Name="Pset_SectioningDevice" Description="Properties of sectioning device used in railway. The property set can be used by the predefined type INSULATOR of IfcDiscreteAccessory." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDiscreteAccessory/INSULATOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SectioningDeviceType_1jE33PRSX1EQ4q4oa7Kb3F" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3BJeIk8cKoOxMLUChbG7Ru" Name="Pset_SectionInsulator" Description="Properties applicable to the insulator type of discrete accessory, indicated that the insulator is a section insulator used in the overhead contact line system." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDiscreteAccessory/INSULATOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ACResistance_2$dT1WHiH7Ge2PeqXa73Sp" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfWires_2vNnC4jfb7dgwh_lRMrBkU" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsArcSuppressing_2bj3cZYAD7qvpndHNlg9vP" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TensileStrength_2Kfn$eiOHEthaq0Mv3o6t4" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3GfFW0qWGHuO00025QrE$V" Name="Pset_SensorPHistory" Description="Properties for history of controller values. HISTORY: Added in IFC4." TemplateType="pset_performancedriven" ApplicableEntity="IfcSensor">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Value_3LQQm0qWGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Direction_3O$JC0qWGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Quality_3R_2E0qWGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_002JG0qWWHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1Aig5GPsT0aBLAgHpFIIZ6" Name="Pset_SensorTypeCO2Sensor" Description="A device that senses or detects carbon dioxide." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSensor/CO2SENSOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SetPointCO2Concentration_3agmoOX1T89fmGtUyWkrgf" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3Z7p60qWGHuO00025QrE$V" Name="Pset_SensorTypeCommon" Description="Sensor type common attributes. HISTORY: Added in IFC4." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSensor">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_3mF220qWGHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="027SE0qWKHuO00025QrE$V" Name="Pset_SensorTypeConductanceSensor" Description="A device that senses or detects electrical conductance. HISTORY: Added in IFC4." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSensor/CONDUCTANCESENSOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SetPointConductance_06IU40qWKHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0E2OM0qWKHuO00025QrE$V" Name="Pset_SensorTypeContactSensor" Description="A device that senses or detects contact. HISTORY: Added in IFC4." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSensor/CONTACTSENSOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SetPointContact_0IpZc0qWKHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1eqxsNkz3GkER1z9cK0W2j" Name="Pset_SensorTypeEarthquakeSensor" Description="Properties that are applicable for IfcSensor with predefined type EARTHQUAKESENSOR." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSensor/EARTHQUAKESENSOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="MarginOfError_0s_xrUcWT9f8dYGpX5qVTI" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LinearVelocityResolution_3QpbSfACX5DheiB5PkB6kH" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SamplingFrequency_206umwul56iODHW70dgFt2" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WorkingState_2qD57tYLb86QIkv8vmjv3f" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DataCollectionType_32vg9H91z7Pu6rUIJWozFI" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DegreeOfLinearity_2eBQocTLT5FgPBdrK2Bskc" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DynamicRange_1_5uyUpJHENuvUg5DlNq32" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EarthquakeSensorRange_3IBX9s4kz9agU5ycgPD6BR" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FullScaleOutput_2WLErKhy1AxhskSWPS52wJ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SerialInterfaceType_0IV69mrp50xeArXDuk$7Y6" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TransverseSensitivityRatio_1t8VvJu1T3TPoInQI3Loie" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EarthquakeSensorType_3flYriVcrCHh7jxmFTBNc_" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0Rlmi0qWKHuO00025QrE$V" Name="Pset_SensorTypeFireSensor" Description="A device that senses or detects the presence of fire." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSensor/FIRESENSOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="FireSensorSetPoint_0WWxy0qWKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AccuracyOfFireSensor_0cUQ00qWKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TimeConstant_0iRu40qWKHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0qnxm0qWKHuO00025QrE$V" Name="Pset_SensorTypeFlowSensor" Description="A device that senses or detects flow. HISTORY: Added in IFC4." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSensor/FLOWSENSOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SetPointFlow_0w9GQ0qWKHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0c2R1WmuPumDEWbUhKspOM" Name="Pset_SensorTypeForeignObjectDetectionSensor" Description="Properties that are applicable for IfcSensor with predefined type FOREIGNOBJECTDETECTIONSENSOR." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSensor/FOREIGNOBJECTDETECTIONSENSOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="WorkingState_2qD57tYLb86QIkv8vmjv3f" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SerialInterfaceType_0IV69mrp50xeArXDuk$7Y6" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ForeignObjectDetectionSensorType_3ev2SAoQX3Lgt5$_Dbrj6Q" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3jJM37QAz1j9BAAWcE0qp4" Name="Pset_SensorTypeFrostSensor" Description="A device that senses or detects the presence of frost." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSensor/FROSTSENSOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SetPointFrost_0iQ5Kw98r0C9GuEQY0RhrH" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="13hcw0qWKHuO00025QrE$V" Name="Pset_SensorTypeGasSensor" Description="A device that senses or detects gas. HISTORY: Changed in IFC4. Gas detected made into enumeration, set point concentration and coverage area added. Range, accuracy and time constant deleted." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSensor/GASSENSOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GasDetected_192xa0qWKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SetPointConcentration_1HO$G0qWKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoverageArea_1gRAK0qWKHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1wX8I0qWKHuO00025QrE$V" Name="Pset_SensorTypeHeatSensor" Description="A device that senses or detects heat. HISTORY: In IFC4, incorporates Fire Sensor. HeatSensorSetPoint changed to SetPointTemperature" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSensor/HEATSENSOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoverageArea_1gRAK0qWKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SetPointTemperature_24feC0qWKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RateOfTemperatureRise_2C$hu0qWKHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2Iz9y0qWKHuO00025QrE$V" Name="Pset_SensorTypeHumiditySensor" Description="A device that senses or detects humidity. HISTORY: HumiditySensorSetPoint changed to SetPointHumidity. Range, accuracy and time constant deleted." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSensor/HUMIDITYSENSOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SetPointHumidity_2ce0M0qWKHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1l8yK5XlT5NQ9XSXlC7wdg" Name="Pset_SensorTypeIdentifierSensor" Description="A device that senses identification tags." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSensor/IDENTIFIERSENSOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SetPointIdentifier_1Hi710k957tQNt0RZYHhzY" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2mmWG0qWKHuO00025QrE$V" Name="Pset_SensorTypeIonConcentrationSensor" Description="A device that senses or detects ion concentration such as water hardness. HISTORY: Added in IFC4." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSensor/IONCONCENTRATIONSENSOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SubstanceDetected_2s7qw0qWKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SetPointIonConcentration_2yhSO0qWKHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="351W40qWKHuO00025QrE$V" Name="Pset_SensorTypeLevelSensor" Description="A device that senses or detects fill level. HISTORY: Added in IFC4." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSensor/LEVELSENSOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SetPointLevel_39ohK0qWKHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3SHEw0qWKHuO00025QrE$V" Name="Pset_SensorTypeLightSensor" Description="A device that senses or detects light. HISTORY: LightSensorSensorSetPoint changed to SetPointIlluminance. Range, accuracy and time constant deleted." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSensor/LIGHTSENSOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SetPointIlluminance_3XeZa0qWKHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3fOTs0qWKHuO00025QrE$V" Name="Pset_SensorTypeMoistureSensor" Description="A device that senses or detects moisture. HISTORY: Added in IFC4." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSensor/MOISTURESENSOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SetPointMoisture_3k9f60qWKHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3uI900qWKHuO00025QrE$V" Name="Pset_SensorTypeMovementSensor" Description="A device that senses or detects movement. HISTORY: In IFC4, time constant deleted." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSensor/MOVEMENTSENSOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="MovementSensingType_3z3KG0qWKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SetPointMovement_09aPo0qWOHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0Jivi0qWOHuO00025QrE$V" Name="Pset_SensorTypePHSensor" Description="A device that senses or detects acidity. HISTORY: Added in IFC4." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSensor/PHSENSOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SetPointPH_0P4EM0qWOHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0XQI20qWOHuO00025QrE$V" Name="Pset_SensorTypePressureSensor" Description="A device that senses or detects pressure. HISTORY: PressureSensorSensorSetPoint changed to SetPointPressure. Range, accuracy and time constant deleted." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSensor/PRESSURESENSOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SetPointPressure_0cBTI0qWOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsSwitch_0mw6c0qWOHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0tTk40qWOHuO00025QrE$V" Name="Pset_SensorTypeRadiationSensor" Description="A device that senses or detects radiation. HISTORY: Added in IFC4." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSensor/RADIATIONSENSOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SetPointRadiation_0yr2k0qWOHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="16NPE0qWOHuO00025QrE$V" Name="Pset_SensorTypeRadioactivitySensor" Description="A device that senses or detects atomic decay. HISTORY: Added in IFC4." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSensor/RADIOACTIVITYSENSOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SetPointRadioactivity_1Bkju0qWOHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3RQD8HTvwxVvPX1nbHsctP" Name="Pset_SensorTypeRainSensor" Description="Properties that are applicable for IfcSensor with predefined type RAINSENSOR." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSensor/RAINSENSOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="MarginOfError_0s_xrUcWT9f8dYGpX5qVTI" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SamplingFrequency_206umwul56iODHW70dgFt2" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WorkingState_2qD57tYLb86QIkv8vmjv3f" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DataCollectionType_32vg9H91z7Pu6rUIJWozFI" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LengthMeasureResolution_1oWya9l0P0zADha8jVgnSi" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SerialInterfaceType_0IV69mrp50xeArXDuk$7Y6" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RainMeasureRange_16cT3SUBL7WQSBYhySMcyR" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RainSensorType_1UG6PIKkT84uhW6B_TLkMI" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1IuUm0qWOHuO00025QrE$V" Name="Pset_SensorTypeSmokeSensor" Description="A device that senses or detects smoke. HISTORY: PressureSensorSensorSetPoint (error in previous release) changed to SetPointConcentration. Range, accuracy and time constant deleted." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSensor/SMOKESENSOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoverageArea_1gRAK0qWKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SetPointConcentration_1HO$G0qWKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasBuiltInAlarm_1eLnO0qWOHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1Z9SboY73_OuCEGxbNqtCu" Name="Pset_SensorTypeSnowSensor" Description="Properties that are applicable for IfcSensor with predefined type SNOWDEPTHSENSOR." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSensor/SNOWDEPTHSENSOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="MarginOfError_0s_xrUcWT9f8dYGpX5qVTI" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SamplingFrequency_206umwul56iODHW70dgFt2" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DataCollectionType_32vg9H91z7Pu6rUIJWozFI" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ImageResolution_1ulCcMFG1EThizMRoqB5OU" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ImageShootingMode_05XzrlWZHBm92_8rlLkSV7" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SerialInterfaceType_0IV69mrp50xeArXDuk$7Y6" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LengthMeasureResolution_1oWya9l0P0zADha8jVgnSi" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SnowSensorMeasureRange_0d_Zd1PZX8FgpMBKTSbIxe" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SnowSensorType_1ujtLLwfjDxxNkuM8GadCz" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1m5hg0qWOHuO00025QrE$V" Name="Pset_SensorTypeSoundSensor" Description="A device that senses or detects sound. HISTORY: SoundSensorSensorSetPoint changed to SetPointSound. Range, accuracy and time constant deleted." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSensor/SOUNDSENSOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SetPointSound_1qGjW0qWOHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1ycnC0qWOHuO00025QrE$V" Name="Pset_SensorTypeTemperatureSensor" Description="A device that senses or detects temperature. HISTORY: TemperatureSensorSensorSetPoint changed to SetPointTemperature. Range, accuracy and time constant deleted." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSensor/TEMPERATURESENSOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="TemperatureSensorType_21NyS0qWOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SetPointTemperature_2JGMe0qWOHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2GkeJx1gQtfvBSURKxSB0N" Name="Pset_SensorTypeTurnoutClosureSensor" Description="Properties that are applicable for IfcSensor with predefined type TURNOUTCLOSURESENSOR." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSensor/TURNOUTCLOSURESENSOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="DetectionRange_18tiQnmqr3a9LRMZ$sdhle" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IndicationRodMovementRange_2EWdqFr25C5QKm2WsoAIDD" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2TOsY0qWOHuO00025QrE$V" Name="Pset_SensorTypeWindSensor" Description="A device that senses or detects wind speed and direction. HISTORY: Added in IFC4." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSensor/WINDSENSOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="WindSensorType_2YmBC0qWOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SetPointSpeed_2sR1c0qWOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DampingRatio_2PtTTcE0vEpOii8kDqjGba" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SerialInterfaceType_0IV69mrp50xeArXDuk$7Y6" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MarginOfError_0s_xrUcWT9f8dYGpX5qVTI" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LinearVelocityResolution_3QpbSfACX5DheiB5PkB6kH" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SamplingFrequency_206umwul56iODHW70dgFt2" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="StartingWindSpeed_1WVoOImSPC5vxwgP5hvg3Y" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WorkingState_2qD57tYLb86QIkv8vmjv3f" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TimeConstant_0iRu40qWKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DataCollectionType_32vg9H91z7Pu6rUIJWozFI" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WindAngleRange_1DH_IenR1EWgR3G1pApMRJ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WindSpeedRange_3prEZg_014axLq1m30EpZt" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2zaoU0qWOHuO00025QrE$V" Name="Pset_ServiceLife" Description="Captures the period of time that an artifact will last. HISTORY: Introduced in IFC2X4 as replacement for IfcServiceLife." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcElement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ServiceLifeDuration_3gtzM0qWOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MeanTimeBetweenFailure_2EilHdaS92vxcNcMLf5IrF" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1HchKxcpX8r9J3ol3Qo6YE" Name="Pset_ServiceLifeFactors" Description="Captures various factors that impact the expected service life of elements within the system or zone." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcSystem">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="QualityOfComponents_3LzIU75Rv2eBKvppy605JZ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DesignLevel_2DT$ZBabjC$RwaWm7qB8cW" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WorkExecutionLevel_2iUDdWqvj3zAyiUtMMrWPd" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IndoorEnvironment_2h9yA6q2T9ZfOglK_Wohce" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OutdoorEnvironment_2PYAiYllv5oQiyb9SiORsG" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InUseConditions_0th9Dg6mf2lwF0z9cCob3a" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaintenanceLevel_2Nvr9q12L4g9osMugKTcqm" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0_whe0qWSHuO00025QrE$V" Name="Pset_ShadingDeviceCommon" Description="Shading device properties associated with an element that represents a shading device" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcShadingDevice">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_1EQWC0qWSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShadingDeviceType_1TwKm0qWSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MechanicalOperated_1lCbY0qWSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SolarTransmittance_1vxEs0qWSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SolarReflectance_25G1a0qWSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VisibleLightTransmittance_1$IZW0qWSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VisibleLightReflectance_2SVmQ0qWSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ThermalTransmittance_1rA3c0qWSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsExternal_1frGu0qWSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Roughness_2Xt540qWSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SurfaceColour_2eQiY0qWSHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2mAcq0qWSHuO00025QrE$V" Name="Pset_ShadingDevicePHistory" Description="Shading device performance history attributes." TemplateType="pset_performancedriven" ApplicableEntity="IfcShadingDevice">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="TiltAngle_2p9Ls0qWSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Azimuth_36E2s0qWSHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1xIRLMm710bALg3ccWDNM5" Name="Pset_ShipLockCommon" Description="Properties common to the definition of all occurrences of _IfcMarineFacility_ with the predefined type set to SHIPLOCK." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcMarineFacility/SHIPLOCK">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="CillLevelUpperHead_3K32apJvH1uOfG1IRMzQCs" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CillLevelLowerHead_3v8srrGkv5BxHCEgUYjye4" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WaterDeliveryValveType_389nXpsIbAVvQpQ2vnIlSG" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WaterDeliverySystemType_1Q07jhdBbBTg0$YC_3U_JM" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1cUbIKgVj6bhokrHY91cLH" Name="Pset_ShiplockComplex" Description="Properties common to the definition of occurrences of _IfcMarineFacility_ with the predefined type set to SHIPLOCK, where the facility represents a complex of multiple shiplocks." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcMarineFacility/SHIPLOCK">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="LockGrade_0afpeKNpXAKuHqMZlEs7GD" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LockLines_3C7vosE2r9xg8_bdQ0FZvD" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LockChamberLevels_0vmNm3RpjAFxGZPkc8F$8N" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LockMode_3FQU_MOXLE7gE5hin075dS" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1DK8qCEMTBReeR23pBwQJp" Name="Pset_ShiplockDesignCriteria" Description="Properties common to the definition of design criteria of all occurrences of IfcMarineFacility with the predefined type set to SHIPLOCK." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcMarineFacility/SHIPLOCK">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumUpstreamNavigableWaterLevel_3jdSJhHEL5WvgepJxzsoPV" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MinimumUpstreamNavigableWaterLevel_3yYWu7oXT8NRxYQB125A$Q" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumDownstreamNavigableWaterLevel_2KNCBf$Sn0g848dtBdpxZF" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MinimumDownstreamNavigableWaterLevel_2EA1AgdafA1wVAWJFBm1jo" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UpstreamMaintenanceWaterLevel_0F2UdpFPTApeBET26XpMXu" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DownstreamMaintenanceWaterLevel_1S4qXKLwH6Gxj0PUEAiq1B" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UpstreamFloodWaterLevel_0OpoEwb5L2EudbjvkVhtcK" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DownstreamFloodWaterLevel_2Z_e7eAXf2IBbTY$1wtozr" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3aRLpVTAHF6OViVDAR88CY" Name="Pset_ShipyardCommon" Description="Properties common to the definition of all occurrences of IfcMarineFacility with the predefined type set to SHIPYARD." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcMarineFacility/SHIPYARD">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="PrimaryProductionType_0V_$0qqDn9Tf1PLPQjjK_e" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3Iz6ikDBs8KJc$4h8qJefM" Name="Pset_SignalFrame" Description="Properties that define signal frame parameters for occurrences and types of _IfcSignal_ applied in railways." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSignal">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="BackboardType_2AeuY0f$T5tOa37WsvTOTr" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SignalFrameType_0Q2X5ruSX1Nw3$GFV6xLWa" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalWidth_2YZfyYRY1Aa9bsWGvZEaNq" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SignalIndicatorType_0Shkb4IIr0WOC35qEoq_UO" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SignalFrameBackboardHeight_0v1lz2quLCXOlGd9GKfrFH" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SignalFrameBackboardDiameter_19LadSgq58jetZa7IOZtqZ" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1hYjDwJwf46xFo6mGj9bhm" Name="Pset_SignCommon" Description="Common properties for Signs." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSign">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsExternal_0AhTG0qTmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Category_06lec0qRqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TactileMarking_1z05xhBET6pvjbZKPdkuil" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3AP4i0qWSHuO00025QrE$V" Name="Pset_SiteCommon" Description="Properties common to the definition of all occurrences of IfcSite. Please note that several site attributes are handled directly at the IfcSite instance, the site number (or short name) by IfcSite.Name, the site name (or long name) by IfcSite.LongName, and the description (or comments) by IfcSite.Description. The land title number is also given as an explicit attribute IfcSite.LandTitleNumber. Actual site quantities, like site perimeter, site area and site volume are provided by IfcElementQuantity, and site classification according to national building code by IfcClassificationReference. The global positioning of the site in terms of Northing and Easting and height above sea level datum is given by IfcSite.RefLongitude, IfcSite.RefLatitude, IfcSite.RefElevation and the postal address by IfcSite.SiteAddress." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcSite">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BuildableArea_3JLHo0qWSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SiteCoverageRatio_3O6T20qWSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FloorAreaRatio_3TTni0qWSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BuildingHeightLimit_3Yr6M0qWSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TotalArea_3gb0e0qWSHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1JvhB_0zD5R8Kw6OP1cvea" Name="Pset_SiteWeather" Description="Properties for site weather" TemplateType="pset_occurrencedriven" ApplicableEntity="IfcSite">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaxAmbientTemp_2bwEkyjJXFoviZOlfCxGbY" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MinAmbientTemp_3LmzG9mwD5cAShoiWv1sOj" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3mYUi0qWSHuO00025QrE$V" Name="Pset_SlabCommon" Description="Properties common to the definition of all occurrences of IfcSlab. Note: Properties for PitchAngle added in IFC 2x3" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSlab">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_002JG0qWWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AcousticRating_0D9YC0qWWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FireRating_0Jj9g0qWWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PitchAngle_19MOE0qWWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Combustible_0QGn80qWWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SurfaceSpreadOfFlame_0WEFC0qWWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Compartmentation_11cTy0qWWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsExternal_0qVF00qWWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ThermalTransmittance_0kXmy0qWWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LoadBearing_0x2sU0qWWHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="24AbvEeJ7gNK$t4NRxj4ey" Name="Pset_SlabTypeTrackSlab" Description="Properties in this property set are generally applicable slabs used in railway tracks, modelled as IfcSlab with PredefinedType TRACKSLAB." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSlab/TRACKSLAB">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="TechnicalStandard_2M$Q1oBlHFBhUArnmHLc4W" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1FJsI0qWWHuO00025QrE$V" Name="Pset_SolarDeviceTypeCommon" Description="Common properties for solar device types." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSolarDevice">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_1Rqxq0qWWHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1A6douNYvBmhZxhl$8GIc5" Name="Pset_SolidStratumCapacity" Description="Properties expressing the capacity of a stratum using physical measures. Regional and National conventions should be captured through classification and specific property sets." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcGeotechnicalStratum/SOLID">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="CohesionBehaviour_1Ts3cC4K527A$xCe0PeqiV" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FrictionAngle_1XV$MSCjTDXgy6O1qRcwC4" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FrictionBehaviour_2hk0eZaUv0hgmvkItMOeJC" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrainSize_1HTwj3_Z583xdSnaDCG6Bx" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HydraulicConductivity_0n5hy7wA9CGeRruzAkgVAG" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LoadBearingCapacity_2r2w0IRgj2ZPPZHhlnoADU" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NValue_2qQ8t_$IrCOuKLzuLwmHI8" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PermeabilityBehaviour_04LPHXtef7Bf46YoPubSZ$" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PoisonsRatio_3ZGJpY849AUhml6K4M4C95" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PwaveVelocity_25QNLFrcX23AOU3hgpu9do" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Resistivity_0CD1$azajCjeK721qDipOz" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SettlementBehaviour_0aIsBh0U1FvRDCb7jNj9zg" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SwaveVelocity_0Zt9yzVWjF3QUsVuryk8eT" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1tHvmcNbD67AtIqQDpgnT5" Name="Pset_SolidStratumComposition" Description="Properties expressing the composition of a stratum using volume measures, implementing ISO14688 Part 2 Table 1 Primary fractions and composite fractions. Regional and National conventions should be captured through classification and specific property sets. Zero values may be omitted." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcGeotechnicalStratum/SOLID">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="AirVolume_2LIPiC_nX0J94McWTlYCrl" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BouldersVolume_1R39LZPv19iQPBk6DS_nYX" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ClayVolume_1ELNjzhfv7fO4ST_8v15TT" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CobblesVolume_3EnkiYvo91k92LY_eT$sR1" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ContaminantVolume_3j3luG3knB79dbgpp9O2W0" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FillVolume_01qLQPtGjD18MWw5eA$xzs" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GravelVolume_2PeYcOedfAx9gaB4_6ou2V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OrganicVolume_1XE1BR1QPCRhABB7nartLU" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RockVolume_0SPTVxj$v8yRPpgU52A4YI" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SandVolume_20m14N5iL90PJuL8U083Zy" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SiltVolume_0YWCMc_RzDo8BnE1x52QEb" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WaterVolume_2JzgU4s2TF4e6fts$U63bp" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CompositeFractions_3vTKU5hpb51Qve8ObZwhUJ" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1kJVQ0qWWHuO00025QrE$V" Name="Pset_SoundAttenuation" Description="Common definition to capture sound pressure at a point on behalf of a device typically used within the context of building services and flow distribution systems.   To indicate sound values from an instance of IfcDistributionFlowElement at a particular location, IfcAnnotation instance(s) should be assigned to the IfcDistributionFlowElement through the IfcRelAssignsToProduct relationship. The IfcAnnotation should specify ObjectType of &apos;Sound&apos; and geometric representation of &apos;Annotation Point&apos; consisting of a single IfcPoint subtype as described at IfcAnnotation.  This property set is instantiated multiple times on an object for each frequency band. HISTORY: New property set in IFC Release 2x4." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcAnnotation">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SoundScale_1qGzU0qWWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SoundFrequency_20o300qWWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SoundPressure_25ZEG0qWWHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2AKPW0qWWHuO00025QrE$V" Name="Pset_SoundGeneration" Description="Common definition to capture the properties of sound typically used within the context of building services and flow distribution systems.  This property set is instantiated multiple times on an object for each frequency band. HISTORY: New property set in IFC Release 2x4." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDistributionFlowElement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SoundCurve_2FhkA0qWWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SoundPressureLevel_0w6C0kuKHCxwHMH3vR34Oa" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1p2RFfTv91ogLVYfaw5gZd" Name="Pset_SpaceAirHandlingDimensioning" Description="Properties for Space AirHandling Dimensioning." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSpatialElement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoolingDesignAirFlow_0P_4O0qWiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HeatingDesignAirFlow_0VxYS0qWiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SensibleHeatGain_0cGHfXw5PB$gkctkiMORlw" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TotalHeatGain_0iSd_0qWiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TotalHeatLoss_0nDpE0qWiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoolingDryBulb_23i_oDW4nDfBvb_ImqAD5i" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoolingRelativeHumidity_0zkum0qWiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HeatingDryBulb_0iNnvmWFL0rwEbwP88DOoa" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HeatingRelativeHumidity_193hU0qWiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VentilationDesignAirFlow_0l5KH$i7vDsewNRQpC1DUw" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DesignAirFlow_0N8C4KOqD4dhxswz_7fyAN" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CeilingRAPlenum_1QLyG0qWiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BoundaryAreaHeatLoss_1XVj80qWiHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2Vni80qWWHuO00025QrE$V" Name="Pset_SpaceCommon" Description="Properties common to the definition of all occurrences of IfcSpace. Please note that several space attributes are handled directly at the IfcSpace instance, the space number (or short name) by IfcSpace.Name, the space name (or long name) by IfcSpace.LongName, and the description (or comments) by IfcSpace.Description. Actual space quantities, like space perimeter, space area and space volume are provided by IfcElementQuantity, and space classification according to national building code by IfcClassificationReference. The level above zero (relative to the building) for the slab row construction is provided by the IfcBuildingStorey.Elevation, the level above zero (relative to the building) for the floor finish is provided by the IfcSpace.ElevationWithFlooring." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSpatialElement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsExternal_3t$SG0qWWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossPlannedArea_00xfM0qWaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetPlannedArea_06v7Q0qWaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PubliclyAccessible_0DSku0qWaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HandicapAccessible_0KcVm0qWaHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1_NWo9Gaz6lwAxpGptBWF4" Name="Pset_SpaceCoveringRequirements" Description="Properties common to the definition of covering requirements of IfcSpace. Those properties define the requirements coming from a space program in early project phases and can later be used to define the room book information, if such coverings are not modeled explicitly as covering elements." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSpatialElement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="FloorCovering_2$qVQcoWX429aMNJ7Te4Wn" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FloorCoveringThickness_2MKCJJm7zCp9$O57i9dmav" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WallCovering_1f6Jf$P7z59hr$7JkVtHgU" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WallCoveringThickness_14ntMnIWr6nOhOn_DiDAD9" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CeilingCovering_3QWyGZN1r0gwbH3sg_91Bs" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CeilingCoveringThickness_2hshDd$CPB2B0zM4kkk1d8" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SkirtingBoard_1jQqq0eYDBaBJh6G7AM_Ar" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SkirtingBoardHeight_2l4adt7h95UQhiXngafYXx" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Molding_0$dALs9697$ulSebIsKQ5Q" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MoldingHeight_0U099eBbD7ihB51GlGFk4H" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConcealedFlooring_26KAQ9kWPDzfy5AeUh1my2" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConcealedFlooringOffset_1M0f51fy10nAxr6YGleM4V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConcealedCeiling_1r0lqqj$f9Ge364Ax4U713" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConcealedCeilingOffset_2dq7B8tp95lPmRb2JNyrg7" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0g3oO0qWaHuO00025QrE$V" Name="Pset_SpaceFireSafetyRequirements" Description="Properties related to fire protection of spaces that apply to the occurrences of IfcSpace or IfcZone." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSpatialElement,IfcSpatialZone,IfcZone">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="FireRiskFactor_0pc8u0qWaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FlammableStorage_0yYL_0qWaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FireExit_1sylo0qWaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SprinklerProtection_1_6Wg0qWaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SprinklerProtectionAutomatic_243_k0qWaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AirPressurization_2Bpv00qWaHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2K9yi0qWaHuO00025QrE$V" Name="Pset_SpaceHeaterPHistory" Description="Space heater performance history common attributes." TemplateType="pset_performancedriven" ApplicableEntity="IfcSpaceHeater">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="FractionRadiantHeatTransfer_2Q7Qm0qWaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FractionConvectiveHeatTransfer_2SW0O0qWaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Effectiveness_2Wh2E0qWaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SurfaceTemperature_2Z3ds0qWaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SpaceAirTemperature_2c2Mu0qWaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SpaceMeanRadiantTemperature_2fdFK0qWaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AuxiliaryEnergySourceConsumption_2joHA0qWaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UACurve_2nN9c0qWaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OutputCapacityCurve_2skUG0qWaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AirResistanceCurve_2vjDI0qWaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CharacteristicExponent_2zuF80qWaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HeatOutputRate_31T7a0qWaHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="35e9Q0qWaHuO00025QrE$V" Name="Pset_SpaceHeaterTypeCommon" Description="Space heater type common attributes.
SoundLevel attribute deleted in IFC2x2 Pset Addendum: Use IfcSoundProperties instead. Properties added in IFC4" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSpaceHeater">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_3I9Ey0qWaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SpaceHeaterPlacement_3f$7C0qWaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TemperatureClassification_3xtXO0qWaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HeatTransferDimension_07oTW0qWeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HeatTransferMedium_0KviS0qWeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EnergySource_0XQn_0qWeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BodyMass_1FK6G0qWeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ThermalMassHeatCapacity_1Ng9y0qWeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OutputCapacity_1Tde00qWeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ThermalEfficiency_1Zb640qWeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfPanels_1j7Sa0qWeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfSections_1oUnE0qWeHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1v2Oi0qWeHuO00025QrE$V" Name="Pset_SpaceHeaterTypeConvector" Description="Space heater type convector attributes." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSpaceHeater/CONVECTOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ConvectorType_1_PjM0qWeHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2CjF60qWeHuO00025QrE$V" Name="Pset_SpaceHeaterTypeRadiator" Description="Space heater type radiator attributes." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSpaceHeater/RADIATOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="RadiatorType_2HUQM0qWeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TubingLength_2W_Ew0qWeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WaterContent_2fKIc0qWeHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0Vlcm54Ef6uRWiv9Vv8RcV" Name="Pset_SpaceHVACDesign" Description="Properties for HVAC requirements for spaces." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSpatialElement,IfcSpatialZone,IfcZone">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="TemperatureSetPoint_11r$fQ7KjDlvSpQ7GrrYIJ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TemperatureMax_3R51p1q1j1nB$j77VpxtSX" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TemperatureMin_0axtJG7wX0cAvo6TTj6AtN" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TemperatureSummerMax_0rAvWFO9T46xDQqTZIY75g" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TemperatureSummerMin_1EHskDhor4nBUoFSC6S$Bo" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TemperatureWinterMax_0Yn52YjwzE59Ibetj1A02E" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TemperatureWinterMin_2hL5w3nqP2ivONJzi0p2Qa" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HumiditySetPoint_1EvwdsIJzCchlD2WxBx7LQ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HumidityMax_3k4hawTVb5Ahvmj2kU6M$L" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HumidityMin_2FMCtdeG12eO0syuCDdRg4" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HumiditySummer_33Q$I6qEfEqR6EBSPjSvTF" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HumidityWinter_2HWhTpDuvDQfU6PHZnzsch" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DiscontinuedHeating_26m100qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NaturalVentilation_2DJeU0qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NaturalVentilationRate_2KTPM0qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MechanicalVentilation_0b_MA3aeHFSwAPtjY25vZM" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MechanicalVentilationRate_2QQtQ0qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AirConditioning_2VoC40qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AirConditioningCentral_2blg80qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AirHandlingName_3V3178UIjCuAR8LYKkcIXJ" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2gl_MPiY9Fje_oQ_rqV4Ku" Name="Pset_SpaceLightingDesign" Description="Properties for requirements on Lighting of spaces." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSpatialElement,IfcSpatialZone,IfcZone">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ArtificialLighting_2rFEk0qWeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Illuminance_2xCio0qWeHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2ltw40qWeHuO00025QrE$V" Name="Pset_SpaceLightingRequirements" Description="Properties related to the lighting requirements that apply to the occurrences of IfcSpace or IfcZone. This includes the required artificial lighting, illuminance, etc." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSpace, IfcSpatialZone, IfcZone">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ArtificialLighting_2rFEk0qWeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Illuminance_2xCio0qWeHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="32MTg0qWeHuO00025QrE$V" Name="Pset_SpaceOccupancyRequirements" Description="Properties concerning work activities occurring or expected to occur within one or a set of similar spatial structure elements." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSpatialElement,IfcSpatialZone,IfcZone">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="OccupancyType_38Jxk0qWeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OccupancyNumber_3FTic0qWeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OccupancyNumberPeak_3Kr1G0qWeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OccupancyTimePerDay_3QoVK0qWeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AreaPerOccupant_3WlzO0qWeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MinimumHeadroom_3c7I20qWeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsOutlookDesirable_3guTI0qWeHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3oeNa0qWeHuO00025QrE$V" Name="Pset_SpaceParking" Description="Properties common to the definition of all occurrences of IfcSpace which have an attribute value for ObjectType = &apos;Parking&apos;.NOTE Modified in IFC 2x3, properties ParkingUse and ParkingUnits added." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSpace/PARKING">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ParkingUse_3tPYq0qWeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ParkingUnits_3$lcW0qWeHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsAisle_056xA0qWiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsOneWay_0CGi20qWiHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0K0cK0qWiHuO00025QrE$V" Name="Pset_SpaceThermalDesign" Description="Space or zone HVAC design requirements. HISTORY: New property set in IFC Release 1.0 (Pset_SpaceHvacInformation); renamed to Pset_SpaceThermalDesign and revised in IFC2x2." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSpace">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoolingDesignAirFlow_0P_4O0qWiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HeatingDesignAirFlow_0VxYS0qWiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TotalSensibleHeatGain_0bv0W0qWiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TotalHeatGain_0iSd_0qWiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TotalHeatLoss_0nDpE0qWiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoolingDryBulb_0uNa60qWiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoolingRelativeHumidity_0zkum0qWiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HeatingDryBulb_13iMq0qWiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HeatingRelativeHumidity_193hU0qWiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VentilationAirFlowrate_1FdIy0qWiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ExhaustAirFlowrate_1K_dc0qWiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CeilingRAPlenum_1QLyG0qWiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BoundaryAreaHeatLoss_1XVj80qWiHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1efU00qWiHuO00025QrE$V" Name="Pset_SpaceThermalLoad" Description="The space thermal load defines all thermal losses and gains occurring within a space or zone. The thermal load source attribute defines an enumeration of possible sources of the thermal load. The maximum, minimum, time series and app" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSpatialElement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="People_1k0og0qWiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Lighting_1qaQ80qWiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EquipmentSensible_20VMG0qWiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VentilationIndoorAir_272zk0qWiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VentilationOutdoorAir_2FP1Q0qWiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RecirculatedAir_2N8xi0qWiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ExhaustAir_2TiZA0qWiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AirExchangeRate_2asK20qWiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DryBulbTemperature_2$gxK0qWiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RelativeHumidity_36qiC0qWiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InfiltrationSensible_3EacU0qWiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TotalSensibleLoad_3MKWm0qWiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TotalLatentLoad_3U4R20qWiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TotalRadiantLoad_3ep4M0qWiHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3nlHS0qWiHuO00025QrE$V" Name="Pset_SpaceThermalLoadPHistory" Description="This property set defines actual measured thermal losses and gains occurring within a space or zone. The thermal load source attribute defines an enumeration of possible sources of the thermal load." TemplateType="pset_performancedriven" ApplicableEntity="IfcSpatialElement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="PeopleHistory_3tilW0qWiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LightingHistory_3whUY0qWiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EquipmentSensibleHistory_3zgDa0qWiHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VentilationIndoorAirHistory_002pC0qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VentilationOutdoorAirHistory_031YE0qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RecirculatedAirHistory_060HG0qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ExhaustAirHistory_08$0I0qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AirExchangeRateTimeHistory_0BzlK0qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DryBulbTemperatureHistory_0FYdm0qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RelativeHumidityHistory_0IXMo0qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InfiltrationSensibleHistory_0LW5q0qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TotalSensibleLoadHistory_0OUqs0qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TotalLatentLoadHistory_0RTZu0qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TotalRadiantLoadHistory_0USIw0qWmHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0YdKm0qWmHuO00025QrE$V" Name="Pset_SpaceThermalPHistory" Description="Thermal and air flow conditions of a space or zone. HISTORY: New property set in IFC 2x2." TemplateType="pset_performancedriven" ApplicableEntity="IfcSpatialElement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoolingAirFlowRate_0d_fQ0qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HeatingAirFlowRate_0hZXs0qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VentilationAirFlowRateHistory_0kYGu0qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ExhaustAirFlowRate_0nW$w0qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SpaceTemperatureHistory_0r5uM0qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SpaceRelativeHumidity_0ugmo0qWmHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0yroe0qWmHuO00025QrE$V" Name="Pset_SpaceThermalRequirements" Description="Properties related to the comfort requirements for thermal and other  thermal related performance properties of spaces that apply to the occurrences of IfcSpace, IfcSpatialZone or IfcZone. It can also be used to capture requirements for IfcSpaceType&apos;s. This includes the required design temperature, humidity, ventilation, and air conditioning." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSpace, IfcSpatialZone, IfcZone">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SpaceTemperature_12pGi0qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SpaceTemperatureMax_18mkm0qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SpaceTemperatureMin_1EkCq0qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SpaceTemperatureSummerMax_1K5XU0qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SpaceTemperatureSummerMin_1Q2$Y0qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SpaceTemperatureWinterMax_1W0Tc0qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SpaceTemperatureWinterMin_1bzxg0qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SpaceHumidity_1hxPk0qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SpaceHumidityMax_1mia_0qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SpaceHumidityMin_1sg320qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SpaceHumiditySummer_1y1Ni0qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SpaceHumidityWinter_21OiM0qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DiscontinuedHeating_26m100qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NaturalVentilation_2DJeU0qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NaturalVentilationRate_2KTPM0qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MechanicalVentilationRate_2QQtQ0qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AirConditioning_2VoC40qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AirConditioningCentral_2blg80qWmHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1CaDsiTFP8NOCV7kiORNT2" Name="Pset_SpatialGeoObsBorehole" Description="Properties for geoscience observations in boreholes." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcBorehole">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="BoreholeElevation_0zNwWthFTDjuOnS8GoqDch" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BoreholeInclination_0DT5srGsL6xA1DS1X9AiCL" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BoreholeAzimuth_0gN7ztT89FlOcDscg5dCUo" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BoreholePurpose_19nhs50GzAe8WtYEV3BYlH" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Operator_39FqXYJQT2U9LFyRW241DI" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DrillingContractor_3Pf78hscf4NOQSyScVWVgk" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BoreholeLengthPlanned_1_khbjyjf8z9JjevtGbGtr" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BoreholeLengthDrilled_3Q4N7zz8fFIPA03iGeIzS1" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DrillingMethod_2tlZTCJoP5V9xcumCFudxO" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1hXmh68iTELerf8DOKyIQl" Name="Pset_SpatialGeoObsExcavatedZone" Description="Common properties for excavated zone observations." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcSpatialZone/MAPPEDZONE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="TunnelExcavationMethod_0IxY668fj68P9Wr33SXafb" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ExcavationFaceType_2a9lnvIGXBJf$bF3uy85d9" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ExcavationStep_2DkWfNGnX34fa0JL31BjfI" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ExcavationMethod_2LuXUw8cfApBjhWYFbeWrd" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LogNumber_2H$tb9GtfCP9DRUp61IODv" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="13Dv2xWtH8785vCtZL_6Fv" Name="Pset_SpatialGeoObsFieldOutcrop" Description="Common properties for field outcrop observations." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcSpatialZone/MAPPEDZONE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="AzimuthExposure_287QddVQ16w8cApdbLY7_Q" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SlopeAngle_1e_6tKMk1BoO7cfc4MFmey" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0pCzL8Wb90V9hw8qu5w6Zf" Name="Pset_SpatialGeoObsMappedZoneCommon" Description="Common properties for mapped zone observations." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcSpatialZone/MAPPEDZONE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GSI_0fHcCs3y9Fd95xSlbHGb0C" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RMR_1FyiAF9_X6qxr7V$dZ3Yiv" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Qvalue_20r43TAl93mwVeOtXNHvj4" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0rSMP2KBbFEvbgFGH_Q7Cn" Name="Pset_SpatialGeoObsSample" Description="Common properties for samples." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcGeoScienceObservation/INSITUTESTRESULT,IfcGeoScienceObservation/LABTESTRESULT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SampleType_0WMz0ZD4vElw3tlESF7X88" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SampleBoreholeDepthRange_16N06qRHf0NOknS38zpWxi" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SampleProcedure_11BJJlK11Fr85RrFLwOBti" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SamplePurpose_2iAtC8BjvBEhsp1U8MpM6Y" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SamplingPointType_3snE6alTz82vidqo5JBy_l" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3R62YAntL0PBTs1t9$0VDt" Name="Pset_SpatialGeoObsSensor" Description="Properties describing sensors used for geoscience observations." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcSensor">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="PlacementType_3Fx8gNev9BdO6QiED3BT8F" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MeasurementStartTime_1e49rH$kr5xhN$GPo0KZPo" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MeasurementEndTime_2h0TtkB$f46PgH3YITllt2" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3Qg5LlpWj7egIdDoIJgPeQ" Name="Pset_SpatialGeoObsSlopeArea" Description="Common properties for slope area observations." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcSpatialZone/MAPPEDZONE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SlopeBaseElevation_3UtmGodEP1kfvXMaxiGM$k" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SlopeHeight_14LE8JSevCsetbtSfTo1C0" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="37k1hJReXEeu1VWOVNtvNE" Name="Pset_SpatialGeoObsTunnelFace" Description="Common properties for tunnel face observations." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcSpatialZone/MAPPEDZONE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GroundClassTBM_1_Vnw4BBXCOA6hWdCFm02c" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0FrzQVlZv4rBwQtsDewSnh" Name="Pset_SpatialZoneCommon" Description="Common properties for Spatial Zones." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSpatialZone">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsExternal_0wumB732b2A8dsysfeuKf4" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0aCWH6Z6H27f9hc3QIUowr" Name="Pset_SpatialZoneTypeCompartment" Description="Properties for spatial zones of type compartment." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSpatialZone/COMPARTMENT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalSpacing_1dblNZi9nBpReQYP2Fv0zI" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalWidth_1X9otKcjv7p8Guj7jHwQgt" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalHeight_0ZM6gGT814qRBtBvJJdu5X" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3d9Q$tLIEtf7lfxqsJ_Fg1" Name="Pset_SpringTensioner" Description="Properties of spring tensioner used in railway. The property set can be used by the predefined type TENSIONINGEQUIPMENT of IfcDiscreteAccessory." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDiscreteAccessory/TENSIONINGEQUIPMENT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="TensileStrength_1ZuJdL4cPBOuLWEzKCV5K4" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalWeight_1NkoWVgmHA5xrENqUppTds" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TensioningWorkingRange_1hZAN9lSb1$gRZ34AI$nMh" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2jVaQ0qWmHuO00025QrE$V" Name="Pset_StackTerminalTypeCommon" Description="Common properties for stack terminals." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcStackTerminal">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_2uEDk0qWmHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3AinK0qWmHuO00025QrE$V" Name="Pset_StairCommon" Description="Properties common to the definition of all occurrences of IfcStair." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcStair">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_3P0J40qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfRiser_3eW7e0qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfTreads_3jHIu0qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RiserHeight_3oedY0qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TreadLength_3w_hE0qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NosingLength_2fumLUaIP77AfA4OwuJ2TH" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WalkingLineOffset_2NNvZYNiXEJQrIeliihHby" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TreadLengthAtOffset_16YqziDXjCxOL5p4GBJOeT" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TreadLengthAtInnerSide_2PbjRdz_nFkPSy0dxSVyGX" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WaistThickness_17ibcdsn96z8VizWIKOSnI" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RequiredHeadroom_04X1k0qWqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HandicapAccessible_0Ct5Q0qWqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasNonSkidSurface_0fU8w0qWqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsExternal_0JQiu0qWqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ThermalTransmittance_3YhweyeoP4yfJpfFi81P$3" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LoadBearing_2FnJNsRdfDQ9dzEq8OinWs" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FireRating_0P_KM0qWqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FireExit_0YKO20qWqHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0nE3C0qWqHuO00025QrE$V" Name="Pset_StairFlightCommon" Description="Properties common to the definition of all occurrences of IfcStairFlight." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcStairFlight">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_107kM0qWqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfRiser_3eW7e0qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfTreads_3jHIu0qWmHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RiserHeight_1QyLe0qWqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TreadLength_1ZIPK0qWqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NosingLength_1iEcQ0qWqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WalkingLineOffset_1nbx40qWqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TreadLengthAtOffset_1x8Ha0qWqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TreadLengthAtInnerSide_244Ug0qWqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Headroom_2BqOy0qWqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WaistThickness_2KASe0qWqHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2syn2CitL8_9lf2d_8ZOz3" Name="Pset_Stationing" Description="Specifies stationing parameters for _IfcReferent_." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcReferent">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="IncomingStation_2ScYZDmQ9C9vR878Q0zliC" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Station_2wUFXsqVDB8fwdTk7zGJXN" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasIncreasingStation_34FH6g00XEcAJrdjKZ3gOO" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2qt6HnlhT39h6HTlZO97yX" Name="Pset_StructuralSurfaceMemberVaryingThickness" Description="Thickness parameters of a surface member (structural analysis item) with varying thickness, particularly with linearly varying thickness. The thickness is interpolated/ extrapolated from three points.  The locations of these points are given either in local x,y coordinates of the surface member or in global X,Y,Z coordinates. Either way, these points are required to be located within the face or at the bounds of the face  of the surface member, and they must not be located on a common line. Local and global coordinates shall not be mixed within the same property set instance." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcStructuralSurfaceMemberVarying">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Thickness1_2vQ8Q_UJv0cR2YYII$qZk3" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Location1Local_2zGAa4OsLC_vpMJq9V0dK4" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Location1Global_0VB5hczAH7CvQQx$j1YIft" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Thickness2_05Hc3cHvb68QQzhIbXRNcm" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Location2Local_05ZaO2Wmn1z8Oh7HnpEAUm" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Location2Global_3F_zLtoAvAuxd7yNYHwBJO" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Thickness3_0drSMc4wnCbgTf_mTVte5u" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Location3Local_144HUwHt9CFfHkh4JmV3dQ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Location3Global_2FeT$dKObBQfRWSKCREUA2" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2fJCduL3bDRALN5pAWwCGd" Name="Pset_SumpBusterCommon" Description="Properties for a sump buster." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcElementAssembly/SUMPBUSTER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="TypeDesignation_3_nUqKqXv3xheIJewmELBG" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2KrhT06ZPFSe4VFSxtijkh" Name="Pset_Superelevation" Description="Specifies the general properties for a Superelevation event." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcReferent/SUPERELEVATIONEVENT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Side_1IWqwe1DT37ObnUgQI07BF" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Superelevation_39rujupbvF7OzE476MLsN7" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TransitionSuperelevation_1tKFopZ991qBQ$gAlgfNRm" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="036VAXOE5Dwvbkc$Tbn3G$" Name="Pset_SupportCommon" Description="Properties describing the characteristcs of tunnel support measures." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcBuiltSystem/TUNNEL_SUPPORT,IfcTunnelTypicalSection/EXCAVATIONSUPPORT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfBolts_0mWUnJjvz5Fw1qK0NbSRYD" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GroutingType_2gToDgdT90Pvu0v1XANdjJ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UserDefinedGroutingType_3xklYq_Gr9_8Vj6GCEyJXC" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PlateType_1k0KQdYJT4WhtMu_7lyRTR" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Arrangement_2knBvrIPHFUBYQTIun1d_A" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LongitudinalSpacing_0dbSQlDqf0gx1Y4PXUaaxd" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RadialSpacing_3IFLBXGmnEuu5$jXs$lG3v" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HorizontalSpacing_1UHNsaYer7lfpt1uCNQwnz" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VerticalSpacing_0bD2dVmzLCt9$vqBHrS5Ib" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2Tip80qWqHuO00025QrE$V" Name="Pset_SwitchingDeviceTypeCommon" Description="A switching device is a device designed to make or break the current in one or more electric circuits." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSwitchingDevice">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_2f1bs0qWqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfGangs_2uXQQ0qWqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SwitchFunction_2zul40qWqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasLock_3DOZe0qWqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsIlluminated_3KYKW0qWqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Legend_3R5x_0qWqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SetPoint_3YrsG0qWqHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfPhases_1BIplyxBLFfuml0KvHZ1y2" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3oxqE0qWqHuO00025QrE$V" Name="Pset_SwitchingDeviceTypeContactor" Description="An electrical device used to control the flow of power in a circuit on or off." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSwitchingDevice/CONTACTOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ContactorType_3ti$U0qWqHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0Ca8i0qWuHuO00025QrE$V" Name="Pset_SwitchingDeviceTypeDimmerSwitch" Description="A dimmer switch is a switch that adjusts electrical power through a variable position level action. HISTORY: Added in IFC4." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSwitchingDevice/DIMMERSWITCH">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="DimmerType_0HxTM0qWuHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0Wr8W0qWuHuO00025QrE$V" Name="Pset_SwitchingDeviceTypeEmergencyStop" Description="An emergency stop device acts to remove as quickly as possible any danger that may have arisen unexpectedly." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSwitchingDevice/EMERGENCYSTOP">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SwitchOperation_0bcJm0qWuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfPhases_1BIplyxBLFfuml0KvHZ1y2" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReferenceEnvironmentTemperature_2vgOshA4D0$ems5HSBwemr" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BreakingCapacity_0SRRZKplf9oAKBz3w0a2po" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfEarthFaultRelays_1k$ZC8XKT1wuKG_W4CR0da" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfEmergencyButtons_1ySlWeb$P2uBH_ablyiBv9" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfRelays_2Yk89uN9b7hOCzGWSTtXeS" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfOverCurrentRelays_3_oAOIEqTAGwn2$PdOKte8" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfAffectedPoles_0PbRBXQxbBDPGv$PwwmO6f" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalCurrent_0sDhk0qUWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RatedFrequency_0xk7ZvULjDVACUV9Qs5Q4T" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RatedVoltage_0_oie0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TransformationRatio_1OT80gqCT1y89fMoREiKYr" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0pJi60qWuHuO00025QrE$V" Name="Pset_SwitchingDeviceTypeKeypad" Description="A keypad is a switch supporting multiple functions. HISTORY: Added in IFC4." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSwitchingDevice/KEYPAD">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="KeypadType_0u4tM0qWuHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="17ahw0qWuHuO00025QrE$V" Name="Pset_SwitchingDeviceTypeMomentarySwitch" Description="A momentary switch is a switch that does not hold state. HISTORY: Added in IFC4." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSwitchingDevice/MOMENTARYSWITCH">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="MomentaryType_1CLtA0qWuHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1Ngfu0qWuHuO00025QrE$V" Name="Pset_SwitchingDeviceTypePHistory" Description="Indicates switch positions or levels over time, such as for energy management or surveillance." TemplateType="pset_performancedriven" ApplicableEntity="IfcSwitchingDevice">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SetPointHistory_1RFYK0qWuHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2959lXGRq9Sqob78pplghM" Name="Pset_SwitchingDeviceTypeRelay" Description="Properties in this property set are applicable for _IfcSwitchingDevice_ with PredefinedType _RELAY_." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSwitchingDevice/RELAY">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalHeight_1Fy4XYaJXDTBDDb9f06ofi" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Current_1I1maXboTEcP5x$ShYx_g0" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalLength_0NS18P1J51kRFniH3h5CIL" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InsulationResistance_1ZlGxOxPPFmwm2gfaKJrQQ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ContactResistance_0MnIrCS5P7TweCZZThUwtm" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PullInVoltage_2dz9sHSqLEL9DJguaAm4sn" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReleaseVoltage_0ALfiH0FPD8wl_QfJHs5JI" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Voltage_27j$QobBL4UhVjgWuhQGvz" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalWidth_2YZfyYRY1Aa9bsWGvZEaNq" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1UEHM0qWuHuO00025QrE$V" Name="Pset_SwitchingDeviceTypeSelectorSwitch" Description="A selector switch is a switch that adjusts electrical power through a multi-position action. HISTORY: Added in IFC4." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSwitchingDevice/SELECTORSWITCH">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SelectorType_1Zbc00qWuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SwitchUsage_1m6hY0qWuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SwitchActivation_20oow0qWuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalCurrent_0sDhk0qUWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReferenceEnvironmentTemperature_2vgOshA4D0$ems5HSBwemr" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RatedFrequency_0xk7ZvULjDVACUV9Qs5Q4T" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfPhases_1BIplyxBLFfuml0KvHZ1y2" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalPower_2pu16hiH1CqQv04BNgxAph" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2Lfy80qWuHuO00025QrE$V" Name="Pset_SwitchingDeviceTypeStarter" Description="A starter is a switch which in the closed position controls the application of power to an electrical device." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSwitchingDevice/STARTER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="StarterType_2Pqz_0qWuHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2k5zo0qWuHuO00025QrE$V" Name="Pset_SwitchingDeviceTypeSwitchDisconnector" Description="A switch disconnector is a switch which in the open position satisfies the isolating requirements specified for a disconnector.

History: Property &apos;HasVisualIndication&apos; changed to &apos;IsIlluminated&apos; to conform with property name for toggle switch" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSwitchingDevice/SWITCHDISCONNECTOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SwitchDisconnectorType_2pTIS0qWuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LoadDisconnectionType_35xs20qWuHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3J34_0qWuHuO00025QrE$V" Name="Pset_SwitchingDeviceTypeToggleSwitch" Description="A toggle switch is a switch that enables or isolates electrical power through a two position on/off action. HISTORY: SetPoint added in IFC4." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSwitchingDevice/TOGGLESWITCH">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ToggleSwitchType_3P0Z20qWuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SwitchUsage_3jtiG0qWuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SwitchActivation_3zzgE0qWuHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3ObBUNX3ofqAL8mCf4VlCf" Name="Pset_SymmetricPairCable" Description="Properties applicable to a symmetric pair cable, which is is a copper cable with a variable number of copper twisted symmetric pair conductors used to transmit data by means of electrical signals. this property set is applicable to type or occurrence of _IfcCableSegment_ with predefined type CABLESEGMENT" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCableSegment/CABLESEGMENT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfTwistedPairs_2FP39QShn07u1Ws2UmRi3_" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfUntwistedPairs_3RNIDzSab848yblJ$4HXKU" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0HeWe0qWyHuO00025QrE$V" Name="Pset_SystemFurnitureElementTypeCommon" Description="Common properties for all systems furniture (I.e. modular furniture) element types (e.g. vertical panels, work surfaces, and storage). HISTORY: First issued in IFC Release R1.5. Renamed from Pset_FurnitureElementCommon" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSystemFurnitureElement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsUsed_0M$rI0qWyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GroupCode_0TZSm0qWyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalWidth_2YZfyYRY1Aa9bsWGvZEaNq" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalHeight_00HWS0qUaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Finishing_0rPL00qWyHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0_xhW0qWyHuO00025QrE$V" Name="Pset_SystemFurnitureElementTypePanel" Description="A set of specific properties for vertical panels that assembly workstations.. HISTORY: First issued in IFC Release R1.5. Renamed from Pset_Panel" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSystemFurnitureElement/PANEL">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasOpening_13ism0qWyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FurniturePanelType_1AGUE0qWyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalThickness_3cTq6sD71BVAf9l72L6lIy" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2XwGB5NX2$w9WSryXb5Iik" Name="Pset_SystemFurnitureElementTypeSubrack" Description="Properties of subrack used in railway telecom. The property set can be used by the predefined type SUBRACK of IfcSystemFurnitureElement" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSystemFurnitureElement/SUBRACK">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfSlots_3ol50yqfz8ZAv5ApU0vpo5" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfUnits_21W3fiATv7tvnEAOCGtP5b" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfOccupiedUnits_1BOKOcsX1EP83zoqRMmf4n" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1e3qY0qWyHuO00025QrE$V" Name="Pset_SystemFurnitureElementTypeWorkSurface" Description="A set of specific properties for work surfaces used in workstations. HISTORY: First issued in IFC Release R1.5. Renamed from Pset_Worksurface" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSystemFurnitureElement/WORKSURFACE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="UsePurpose_1iq$o0qWyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SupportType_1p_mg0qWyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HangingHeight_20VsC0qWyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalThickness_3cTq6sD71BVAf9l72L6lIy" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShapeDescription_2IOGO0qWyHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2RKTU0qWyHuO00025QrE$V" Name="Pset_TankOccurrence" Description="Properties that relate to a tank. Note that a partial tank may be considered as a compartment within a compartmentalized tank." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcTank">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="TankComposition_2Who80qWyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasLadder_2jCtg0qWyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasVisualIndicator_2pmV80qWyHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2y6Yq0qWyHuO00025QrE$V" Name="Pset_TankTypeCommon" Description="Common attributes of a tank type." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcTank">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_35evK0qWyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AccessType_3Im8G0qWyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="StorageType_3WTWc0qWyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalLengthOrDiameter_3lzLA0qWyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalWidthOrDiameter_3tjFS0qWyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalDepth_0HZnE0qUaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TankNominalCapacity_06cwc0qX0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EffectiveCapacity_0AnyS0qX0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OperatingWeight_0FZ7i0qX0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PatternType_0KKIy0qX0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EndShapeType_0V2yG0qX0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FirstCurvatureRadius_0imKc0qX0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SecondCurvatureRadius_0qWEu0qX0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfSections_0ysIa0qX0HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1403S0qX0HuO00025QrE$V" Name="Pset_TankTypeExpansion" Description="Common attributes of an expansion type tank." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcTank/EXPANSION">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ChargePressure_18nEi0qX0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PressureRegulatorSetting_1Q3VU0qX0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReliefValveSetting_1VQq80qX0HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1cab00qX0HuO00025QrE$V" Name="Pset_TankTypePreformed" Description="Fixed vessel manufactured as a single unit with one or more compartments for storing a liquid.

Pset renamed from Pset_TankTypePreformedTank to Pset_TankTypePreformed in IFC2x2 Pset Addendum." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcTank">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="PatternType_1hLmG0qX0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EndShapeType_1uS$C0qX0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FirstCurvatureRadius_2996a0qX0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SecondCurvatureRadius_2IhT40qX0HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2U0Fo0qX0HuO00025QrE$V" Name="Pset_TankTypePressureVessel" Description="Common attributes of a pressure vessel." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcTank/PRESSUREVESSEL">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ChargePressure_2YnR20qX0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PressureRegulatorSetting_2fxBw0qX0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReliefValveSetting_2mUpO0qX0HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2uEjg0qX0HuO00025QrE$V" Name="Pset_TankTypeSectional" Description="Fixed vessel constructed from sectional parts with one or more compartments for storing a liquid.

Note (1): All sectional construction tanks are considered to be rectangular by default.
Note (2): Generally, it is not expected that sectional construction tanks will be used for the purposes of gas storage.

Pset renamed from Pset_TankTypeSectionalTank to Pset_TankTypeSectional in IFC2x2 Pset Addendum." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcTank">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfSections_2zc2K0qX0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SectionLength_349fo0qX0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SectionWidth_3D5su0qX0HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1fBFhuALtxJcyHx6Z3LTrm" Name="Pset_TelecomCableGeneral" Description="Properties common to occurrences and types of IfcCableSegment and IfcCableFitting applied in telecommunication domain." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCableSegment,IfcCableFitting">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Attenuation_0Fn9Y3Mh90ghP0udRXs1Jj" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FireRating_0eTJm0qT0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsFireResistant_0EDQmMlDr4wOieHoEptGkG" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalDiameter_3583UJ6cD6cBUOPJ6Z7hRk" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="JacketColour_1vHztIiLn2ZvG$H5JLPMVP" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CableFunctionType_185zEg3BX9UPnOrdfFpNFk" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CableArmourType_3$2Up8Fxb2RPdKNA2Tyn0M" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0afr3lOTjAwRuvA_oP23t1" Name="Pset_ThermalLoad" Description="Properties for thermal loads of elements." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSpatialElement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="OccupancyDiversity_0OoXU0qX4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LightingDiversity_0Wh9m0qRuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ApplianceDiversity_00MVq0qX4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OutsideAirPerPerson_0Ul$Y0qX4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReceptacleLoadIntensity_0ajTc0qX4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AppliancePercentLoadToRadiant_0ggxg0qX4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LightingLoadIntensity_0nEZ80qX4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LightingPercentLoadToReturnAir_0toAc0qX4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TotalCoolingLoad_3VaQU0qX0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TotalHeatingLoad_3axl80qX0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InfiltrationDiversitySummer_0c2UQ0qRuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InfiltrationDiversityWinter_0hPp40qRuHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LoadSafetyFactor_06Jzu0qX4HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3MeDO0qX0HuO00025QrE$V" Name="Pset_ThermalLoadAggregate" Description="The aggregated thermal loads experienced by one or many spaces, zones, or buildings. This aggregate thermal load information is typically addressed by a system or plant. HISTORY: New property set in IFC Release 1.0 (Pset_AggregateLoadInformation); renamed Pset_ThermalLoadAggregate in IFC2x2." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSpatialElement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="TotalCoolingLoad_3VaQU0qX0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TotalHeatingLoad_3axl80qX0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LightingDiversity_3gvDC0qX0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InfiltrationDiversitySummer_3pFGu0qX0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InfiltrationDiversityWinter_3vouM0qX0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ApplianceDiversity_00MVq0qX4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LoadSafetyFactor_06Jzu0qX4HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0E3uA0qX4HuO00025QrE$V" Name="Pset_ThermalLoadDesignCriteria" Description="Building thermal load design data that are used for calculating thermal loads in a space or building. HISTORY: New property set in IFC Release 1.0 (Pset_LoadDesignCriteria); renamed Pset_ThermalLoadDesignCriteria in IFC2x2." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSpatialElement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="OccupancyDiversity_0OoXU0qX4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OutsideAirPerPerson_0Ul$Y0qX4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReceptacleLoadIntensity_0ajTc0qX4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AppliancePercentLoadToRadiant_0ggxg0qX4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LightingLoadIntensity_0nEZ80qX4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LightingPercentLoadToReturnAir_0toAc0qX4HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="05HbcKX5b4iOuIY57cnkf_" Name="Pset_TicketProcessing" Description="Properties for indicating performance ratings for ticket processing of entry elements (e.g. turnstile, boom barrier)." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcDoor/TURNSTILE,IfcDoor/BOOM_BARRIER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="TicketProcessingTime_17M9Cc_kz818DfWA4GZJTA" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TicketStuckRatio_3yrQ19j3XCuR09jcP_sUQK" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1UljwK3TaaDMvO$0abMJEC" Name="Pset_TicketVendingMachine" Description="Properties of ticket vending machine. The property set can be used by _IfcElectricAppliance_ with PredefinedType VENDINGMACHINE." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcElectricAppliance/VENDINGMACHINE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="TicketStuckRatio_3yrQ19j3XCuR09jcP_sUQK" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MoneyStuckRatio_0woPgPGeb8KAg_EvnJFaFT" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PaymentMethod_1d78lyWYfFdPdM0bVSZdC$" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TicketProductionSpeed_3x1oxWIPb1Ov7kUFZmUNkg" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TicketVendingMachineType_1jryyyP5n7IgJiBTSr7Yqz" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VendingMachineUserInterface_2Zn17rWWTBGhHGhmLqk8UV" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3eqdPQn_90Yf9MsseWlXFk" Name="Pset_Tiling" Description="Properties about tiles." ApplicableEntity="IfcPavement,IfcCovering">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Permeability_3_l1K0qSyHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TileLength_046L_0qT0HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TileWidth_09Tge0qT0HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="21852yrKD2guJGHXYCvyB6" Name="Pset_Tolerance" Description="Properties expressing the tolerance relating to locating and shaping of an intended element or feature. Range diameters are non-negative describing a linear, rectangular or boxed region  ." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcProduct,IfcTypeProduct">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ToleranceDescription_0p2ln6hpL0funX1LED8$P0" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ToleranceBasis_3afnSSHFLAGQqCq3RLp409" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OverallTolerance_3KnChrfTf4b9mBQQxryAs$" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HorizontalTolerance_3$ft4Ga9X6DxvQZ768Kj3w" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OrthogonalTolerance_2_6AHTtATDgu5GyLAb6mQD" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VerticalTolerance_2M1e8BS3PBPPQBW9Q2nF$P" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PlanarFlatness_1knSGb$Hr9DhsNhsqxn5bg" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HorizontalFlatness_0J7SvVYBP1bw$w1Fbxtnea" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ElevationalFlatness_14HXFGUPn1GRTDa16b37bZ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SideFlatness_0IkMojxkv5NevG5Jf0VoEi" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OverallOrthogonality_2Pm3H5PjH4qh$6CcPKvJ0F" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HorizontalOrthogonality_1XAcvVmsb509eDuyDemhcT" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OrthogonalOrthogonality_0ijPx5qb9F0QxopE78gaal" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VerticalOrthogonality_2YlbHbk1D2r9MQG8$pVBmR" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OverallStraightness_0ujePSr190qh2qiYRtw0$1" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HorizontalStraightness_0wr5muKv1DqPs2T8tTtcFR" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OrthogonalStraightness_1o$cWyp49DFveZj70lz4fA" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VerticalStraightness_1bHjGtr3j7MveQ70Lzosub" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="34Wu3CvwuFfSnK3RVXR8hU" Name="Pset_TrackBase" Description="Properties in this property set are applicable for IfcSlab with PredefinedType BASESLAB, indicated that the base slab is a track base slab." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcSlab/BASESLAB">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsSurfaceGalling_1ZjWQaS4v7yRtvDOWbc7uC" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SurfaceGallingArea_1iJuaHmcrBLxVSLz7TLiKj" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3vnsZ4bCq5zQaCC_UNI8G9" Name="Pset_TrackElementOccurrenceSleeper" Description="Properties common to the definition to all occurrences of IfcTrackElement with PredefinedType set to SLEEPER." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcTrackElement/SLEEPER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasSpecialEquipment_1NpljvUif4jvHuguLm4wK5" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SequenceInTrackPanel_2AwvXjv7r7LvJK8xaTQN3z" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UnderSleeperPadStiffness_0iZmbYaC1AVvSMX_LEPB36" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsContaminatedSleeper_3veUeXa7v4mhaYZbSgpKpE" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="02w7sxfC55Eek7boGFLdww" Name="Pset_TrackElementPHistoryDerailer" Description="Indicates derailer information over time for operation management." TemplateType="pset_performancedriven" ApplicableEntity="IfcTrackElement/DERAILER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsDerailing_3hK6$ugfj2heMnYkSgFRIQ" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3g222K$HNGyTrR2U5wbWHJ" Name="Pset_TrackElementTypeDerailer" Description="Properties common to the definition to all occurrences and types of IfcTrackElement with PredefinedType set to DERAILER." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcTrackElement/DERAILER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="AppliedLineLoad_3T5jes7obFcB3kXbkF_EPE" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DerailmentMaximumSpeedLimit_1TbwEaqYL1s9iVqilDO212" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DerailmentWheelDiameter_1gibFX8tbFXx1zQE4aQgil" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DerailmentHeight_1CeYfycR58Q96DOkJI5inh" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3SUItwezHJr0bFLHG85eiH" Name="Pset_TrackElementTypeSleeper" Description="Properties common to the definition to all occurrences and types of IfcTrackElement with PredefinedType set to SLEEPER." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcTrackElement/SLEEPER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="InstalledCondition_0goJ6tJj9ExRS1Ys1pKvH9" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SleeperType_28mz55$2X1V92osWy7KaqR" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TechnicalStandard_2M$Q1oBlHFBhUArnmHLc4W" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FasteningType_1BGxpp0rr4tv$oIacUcEQG" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsElectricallyInsulated_1HhghvvaLAvfFIOypPw7B9" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HollowSleeperUsage_24bWI7gefEm81rwgNZrJim" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfTrackCenters_3PJ_4twh11JeX78ftqwr0D" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsHollowSleeper_1_l7FDgPz3CgHhlHjyAHYa" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3r83SI1HbCL1JttmsMbLN6" Name="Pset_TractionPowerSystem" Description="Properties of a traction power system. The property is associated to the predefined type ELECTRICAL of _IfcDistributionSystem_, and is used to characterise systems such as railway electrical distribution networks used to provide energy for rolling stock." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcDistributionSystem/ELECTRICAL">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="PowerSupplyMode_0R5br9ai188vK3YgXwAZkg" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ElectrificationType_1_UrHKqNv3$w5LVrIbepR6" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RatedFrequency_2e0YIS0SP8ffTho62YkBSL" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalVoltage_3lq2xqPH9FnvgKOz8DOPYt" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0I29__FTjDQRNvWtPjuuOj" Name="Pset_TrafficCalmingDeviceCommon" Description="Properties for a traffic calming device." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcElementAssembly/TRAFFIC_CALMING_DEVICE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="TypeDesignation_3_nUqKqXv3xheIJewmELBG" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0_xxU0qX4HuO00025QrE$V" Name="Pset_TransformerTypeCommon" Description="An inductive stationary device that transfers electrical energy from one circuit to another." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcTransformer">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_1BT100qX4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PrimaryVoltage_1Txac0qX4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SecondaryVoltage_1ZIvG0qX4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PrimaryCurrent_1gSg80qX4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SecondaryCurrent_1n0Hc0qX4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PrimaryFrequency_1tZv40qX4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SecondaryFrequency_1_7WY0qX4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PrimaryApparentPower_23UrC0qX4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SecondaryApparentPower_29SJG0qX4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumApparentPower_2FPnK0qX4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SecondaryCurrentType_2Kn5_0qX4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ShortCircuitVoltage_2Wi260qX4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RealImpedanceRatio_2cfWA0qX4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ImaginaryImpedanceRatio_2ic_E0qX4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TransformerVectorGroup_2LM0i803DFiO3qpXrGIAS7" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsNeutralPrimaryTerminalAvailable_3IAEq0qX4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsNeutralSecondaryTerminalAvailable_3PJ$i0qX4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfPhases_1BIplyxBLFfuml0KvHZ1y2" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2vwpxtmyLF2R6BvJpXJVqR" Name="Pset_TransitionSectionCommon" Description="Properties for a transition section." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcEarthworksFill/TRANSITIONSECTION">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalLength_07RHK0qUaHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3X3v_0qX4HuO00025QrE$V" Name="Pset_TransportationDeviceCommon" Description="Properties common to the definition of all occurrences of _IfcTransportationDevice_ or _IfcTransportationDeviceType_." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcTransportationDevice">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_3fPzg0qX4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_3lzb80qX4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CapacityPeople_003Z60qX8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CapacityWeight_05Qtm0qX8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FireExit_0Caee0qX8HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2uIqxp0XTDL8JePY$YO8Ky" Name="Pset_TransportElementCommon" Description="Properties common to the definition of all occurrences of _IfcTransportElement_ or _IfcTransportElementType_." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcTransportationDevice">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_002JG0qWWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CapacityPeople_003Z60qX8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CapacityWeight_05Qtm0qX8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FireExit_0Caee0qX8HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0LWrk0qX8HuO00025QrE$V" Name="Pset_TransportElementElevator" Description="Properties common to the definition of all occurrences of IfcTransportElement with the predefined type =&quot;ELEVATOR&quot;" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcTransportElement/ELEVATOR">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="FireFightingLift_0QI0_0qX8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ClearWidth_0WreS0qX8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ClearDepth_0fnrY0qX8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ClearHeight_0o7vE0qX8HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3oBPVwLDfBb8msBZBG7fkg" Name="Pset_TransportEquipmentOTN" Description="Properties in this property set are applied to transport equipment that act in optical transport network (OTN) system." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcCommunicationsAppliance/TRANSPORTEQUIPMENT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SingleChannelAveragePower_3rB$_Tjhz6S8Z3ZXo0VSc6" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ChromaticDispersionTolerance_1GC7m4ctzEMR6sRVs2$Rji" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SingleChannelPower_25tcvQ$vv7RRphaUrbQGbb" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MinimumOpticalSignalToNoiseRatio_0rh$rcZcL2wgr$IvyycBvf" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PolarizationModeDispersionTolerance_1l9fqAQsz5qR9XY_Mh244N" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SingleWaveTransmissionRate_1_gN4QLfz9chfxmU_gcIKe" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EquipmentCapacity_37sz88SXT3JOvbrpAb4kbe" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="12rFi2mXL0xRzsq5I_iphE" Name="Pset_TrenchExcavationCommon" Description="Properties for a trench excavation." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcEarthworksCut/TRENCH">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalDepth_0HZnE0qUaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalWidth_2YZfyYRY1Aa9bsWGvZEaNq" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0yGP80qX8HuO00025QrE$V" Name="Pset_TubeBundleTypeCommon" Description="Tube bundle type common attributes." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcTubeBundle">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_18nUg0qX8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfRows_1OHJE0qX8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="StaggeredRowSpacing_1Uqwi0qX8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InLineRowSpacing_1dA_O0qX8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfCircuits_1m7BU0qX8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FoulingFactor_1rUW80qX8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ThermalConductivity_1wrqo0qX8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Length_20D9S0qX8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Volume_299MY0qX8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalDiameter_2EWhC0qX8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OutsideDiameter_2Msku0qX8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InsideDiameter_2VCoa0qX8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HorizontalSpacing_2dYsG0qX8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VerticalSpacing_2mV3M0qX8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasTurbulator_2ur720qX8HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="32zcy0qX8HuO00025QrE$V" Name="Pset_TubeBundleTypeFinned" Description="Finned tube bundle type attributes.
Contains the attributes related to the fins attached to a tube in a finned tube bundle such as is commonly found in coils." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcTubeBundle/FINNED">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Spacing_38x500qX8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Thickness_3HtI60qX8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ThermalConductivity_3RPec0qX8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Length_3XN6g0qX8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Height_3fjAM0qX8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Diameter_3pFWs0qX8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FinCorrugatedType_3yBjy0qX8HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasCoating_03LUq0qXCHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3hV97_eqX8YRtwPSmso1aN" Name="Pset_Uncertainty" Description="Property set capturing the geometric uncertainty regarding measurements including how the way that uncertainty was assessed." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcProduct">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="UncertaintyBasis_3QSaVp2x1CmfjKyHvaJgfs" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UncertaintyDescription_2rw6tfssL7IgbS7PGZcx6e" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HorizontalUncertainty_1QRo9gJgj5XxCUOkwGIQ2K" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LinearUncertainty_0sq832INvCxuwUFe2_4EmP" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OrthogonalUncertainty_1lQaFq2abFIh90SuNnsYAy" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VerticalUncertainty_3pJ9ffcd5D3fYZdbK3HYls" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0oHcwtvib5ShKkSOHCcU5S" Name="Pset_UndergroundExcavationCommon" Description="Common properties for underground excavation elements." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcUndergroundExcavation">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="UndergroundExcavationMethod_0wE_9k6ETFpu7yxLk9g7XY" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SupportDescription_2WLzTqjQX4igKvQThEIOuZ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SupportClass_09LzP6dcn6OAdINBkUxEqS" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ExcavationClass_0M$dI8P5T3I8$lTN_LlVyH" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RoundLength_2Px7GAEKr9oPOVi4hIhBDX" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3moy$PJwnNtph9th3zxEW5" Name="Pset_UnitaryControlElementBaseStationController" Description="Properties that are applicable to _IfcUnitaryControlElement_ with the predefined type set to BASESTATIONCONTROLLER." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcUnitaryControlElement/BASESTATIONCONTROLLER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfInterfaces_3D0wHuI4P3guCzHoS3Y4Zf" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfManagedBTSs_0OHaQ3VtPDL8_RM8WL2hWr" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfManagedCarriers_2dXLs2JgDDJAUunNKdvGyu" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0B5P60qXCHuO00025QrE$V" Name="Pset_UnitaryControlElementPHistory" Description="Properties for history and operating schedules of thermostats. HISTORY: Added in IFC4." TemplateType="pset_performancedriven" ApplicableEntity="IfcUnitaryControlElement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Temperature_0GSjm0qXCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OperationModeHistory_0JRSo0qXCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Fan_0N0LE0qXCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SetPoint_0QbDg0qXCHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0UmFW0qXCHuO00025QrE$V" Name="Pset_UnitaryControlElementTypeCommon" Description="Unitary control element type common attributes. HISTORY: Added in IFC4." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcUnitaryControlElement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_0g52E0qXCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OperationMode_0wn9c0qXCHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0mohp45fzWYYSPBj8mX6SU" Name="Pset_UnitaryControlElementTypeControlPanel" Description="Properties that are applicable to _IfcUnitaryControlElement_ with the predefined type set to CONTROLPANEL." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcUnitaryControlElement/CONTROLPANEL">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalCurrent_1Vh1C0qVaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalPower_2pu16hiH1CqQv04BNgxAph" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RatedVoltage_2YuL_rvIv9uxXdCK0Vu7_6" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReferenceAirRelativeHumidity_1wG8Xp53PDOPLBMvLK0g1J" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReferenceEnvironmentTemperature_2vgOshA4D0$ems5HSBwemr" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3qXjpGdgr5fwKbcURJd0R1" Name="Pset_UnitaryControlElementTypeIndicatorPanel" Description="Unitary control element type indicator panel attributes. HISTORY: Added in IFC4." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcUnitaryControlElement/INDICATORPANEL">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="UnitaryApplication_2Y52cBoBnCBP7WBI0IJIdu" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2IB8yCBBb2FBRBi1EoZWS5" Name="Pset_UnitaryControlElementTypeThermostat" Description="Unitary control element type thermostat attributes. HISTORY: Added in IFC4." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcUnitaryControlElement/THERMOSTAT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="TemperatureSetPoint_3N_YJBMXv4rv$PWDUvcSff" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1JpKg0qXCHuO00025QrE$V" Name="Pset_UnitaryEquipmentTypeAirConditioningUnit" Description="Air conditioning unit equipment type attributes.
Note that these attributes were formerly Pset_PackagedACUnit prior to IFC2x2.
HeatingEnergySource attribute deleted in IFC2x2 Pset Addendum: Use IfcMaterialProperties instead." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcUnitaryEquipment/AIRCONDITIONINGUNIT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="SensibleCoolingCapacity_1QMy80qXCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LatentCoolingCapacity_1rniq0qXCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoolingEfficiency_1xlAu0qXCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HeatingCapacity_22IoM0qXCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HeatingEfficiency_28GGQ0qXCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CondenserFlowrate_2Ddb40qXCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CondenserEnteringTemperature_2Jb380qXCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CondenserLeavingTemperature_2RKzQ0qXCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OutsideAirFlowrate_2XIRU0qXCHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2ds2y0qXCHuO00025QrE$V" Name="Pset_UnitaryEquipmentTypeAirHandler" Description="Air handler unitary equipment type attributes.
Note that these attributes were formerly Pset_AirHandler prior to IFC2x2." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcUnitaryEquipment/AIRHANDLER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="AirHandlerConstruction_2jpX00qXCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AirHandlerFanCoilArrangement_2wwly0qXCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DualDeck_36ri40qXCHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3EbcM0qXCHuO00025QrE$V" Name="Pset_UnitaryEquipmentTypeCommon" Description="Unitary equipment type common attributes." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcUnitaryEquipment">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_3PKFg0qXCHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3fQDe0qXCHuO00025QrE$V" Name="Pset_UtilityConsumptionPHistory" Description="Consumption of utility resources, typically applied to the IfcBuilding instance, used to identify how much was consumed on I.e., a monthly basis." TemplateType="pset_performancedriven" ApplicableEntity="IfcBuilding">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Heat_3knYI0qXCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Electricity_3nmHK0qXCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Water_3ql0M0qXCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Fuel_3tjlO0qXCHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Steam_3wiUQ0qXCHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3_HMs0qXCHuO00025QrE$V" Name="Pset_ValvePHistory" Description="Valve performance history common attributes of a typical 2 port pattern type valve." TemplateType="pset_performancedriven" ApplicableEntity="IfcValve">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="PercentageOpen_03ehW0qXGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MeasuredFlowRate_06dQY0qXGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MeasuredPressureDrop_0AoSO0qXGHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0FZde0qXGHuO00025QrE$V" Name="Pset_ValveTypeAirRelease" Description="Valve used to release air from a pipe or fitting.
Note that an air release valve is constrained to have a single port pattern" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcValve/AIRRELEASE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsAutomatic_0M7F60qXGHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0UTIo0qXGHuO00025QrE$V" Name="Pset_ValveTypeCommon" Description="Valve type common attributes." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcValve">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_0GE0ZFN_PDM9vp5yT9CKUr" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ValvePattern_0d$fI0qXGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ValveOperation_0u5dG0qXGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ValveMechanism_1Hjxk0qXGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Size_1g9zO0qXGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TestPressure_1uTV80qXGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WorkingPressure_1_QzC0qXGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FlowCoefficient_24ORG0qXGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CloseOffRating_2ALvK0qXGHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2I5pc0qXGHuO00025QrE$V" Name="Pset_ValveTypeDrawOffCock" Description="A small diameter valve, used to drain water from a cistern or water filled system." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcValve/DRAWOFFCOCK">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasHoseUnion_2Ms_s0qXGHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2Ucv80qXGHuO00025QrE$V" Name="Pset_ValveTypeFaucet" Description="A small diameter valve, with a free outlet, from which water is drawn." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcValve/FAUCET">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="FaucetType_2Z_Do0qXGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FaucetOperation_2t2wo0qXGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FaucetFunction_3Bw400qXGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Finish_3QDbm0qXGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FaucetTopDescription_3WB3q0qXGHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3ckhI0qXGHuO00025QrE$V" Name="Pset_ValveTypeFlushing" Description="Valve that flushes a predetermined quantity of water to cleanse a WC, urinal or slop hopper.
Note that a flushing valve is constrained to have a 2 port pattern." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcValve/FLUSHING">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="FlushingRate_3i5$y0qXGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasIntegralShutOffDevice_3o3U00qXGHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsHighPressure_3ud5U0qXGHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="00z9A0qXKHuO00025QrE$V" Name="Pset_ValveTypeGasTap" Description="A small diameter valve, used to discharge gas from a system." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcValve/GASTAP">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasHoseUnion_06KTq0qXKHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0E4O60qXKHuO00025QrE$V" Name="Pset_ValveTypeIsolating" Description="Valve that is used to isolate system components.
Note that an isolating valve is constrained to have a 2 port pattern." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcValve/ISOLATING">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsNormallyOpen_0IrZM0qXKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsolatingPurpose_0QbTe0qXKHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0diia0qXKHuO00025QrE$V" Name="Pset_ValveTypeMixing" Description="A valve where typically the temperature of the outlet is determined by mixing hot and cold water inlet flows." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcValve/MIXING">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="MixerControl_0iTtq0qXKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OutletConnectionSize_19h4k0qXKHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1Jpae0qXKHuO00025QrE$V" Name="Pset_ValveTypePressureReducing" Description="Valve that reduces the pressure of a fluid immediately downstream of its position in a pipeline to a preselected value or by a predetermined ratio.
Note that a pressure reducing valve is constrained to have a 2 port pattern." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcValve/PRESSUREREDUCING">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="UpstreamPressure_1Pn2i0qXKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="DownstreamPressure_1VkWm0qXKHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1dUR20qXKHuO00025QrE$V" Name="Pset_ValveTypePressureRelief" Description="Spring or weight loaded valve that automatically discharges to a safe place fluid that has built up to excessive pressure in pipes or fittings.
Note that a pressure relief valve is constrained to have a single port pattern." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcValve/PRESSURERELIEF">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="ReliefPressure_1irli0qXKHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2$z_xSY4H4QhR2$LlQhGbe" Name="Pset_VegetationCommon" Description="Properties for vegetation and plants, modelled as instances of IfcGeographicElement with the predefined type set to VEGETATION." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcGeographicElement/VEGETATION">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="BotanicalName_1wKb_YtzfA_xM$jfazqTfc" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LocalName_0ebn7wWEP34Ad62PIlPZk7" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1FbPDubE1DA9rU9buCvLZL" Name="Pset_VehicleAvailability" Description="Property set for the application of availability data to vehicles and equipment." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcVehicle/ROLLINGSTOCK,IfcVehicle/VEHICLEAIR,IfcVehicle/VEHICLEMARINE,IfcVehicle/VEHICLETRACKED,IfcVehicle/VEHICLE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="VehicleAvailability_09W2Dk$VDCIAO$YGHh$6_6" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaintenanceDowntime_18YJqf1cHB_AgALw4trjcf" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WeatherDowntime_1_PvQpGdP7XerkPpRuxddI" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="15MrSyk291LxDRVgoh5BoK" Name="Pset_VesselLineCommon" Description="Properties for vessel lines and anchoring" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcMechanicalFastener/ROPE,IfcMechanicalFastenerType/ROPE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="LineIdentifier_1PYHABAEb2ZBJGSxWcsNYh" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MidshipToFairLead_38Dt4YAsL4reYsJ6egFlB$" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CentreLineToFairlead_1$AwRqpEfD_9rbUpYn5F65" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HeightAboveMainDeck_1nG3Ga$fP8IAo6dBpx7fCk" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FairleadToTermination_0aBTPQFeHAF9vXo$IOf74h" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WinchBreakLimit_2wHzhEvrvETAgnkW9TL1me" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PreTensionAim_3aicuu8QP28AAdbn5w7Vos" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LineType_2fAOC7skD9Fgvn3zk5Z1Ey" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LineStrength_0htP3VyZ94$vpry8cecGEh" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TailLength_0XwZqNndfAIBo5xGHS38oI" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TailDiameter_2tFbGzZPnF$90SySo7d0Sb" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TailType_1E8vVc_qv18OjQ$L$G70rd" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TailStrength_1U7sKfCoj6xOTd67x3PDsQ" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1p$Wa0qXKHuO00025QrE$V" Name="Pset_VibrationIsolatorTypeCommon" Description="Vibration isolator type common attributes." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcVibrationIsolator">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_0Qc9xk12n40eCxiaK_E2E8" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VibrationTransmissibility_1$KJI0qXKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsolatorStaticDeflection_25twm0qXKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsolatorCompressibility_2BFFQ0qXKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumSupportedWeight_2PYnA0qXKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalHeight_2HCjU0qXKHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1BHnQV1EZpAUM9oYl_93i9" Name="Pset_VoltageInstrumentTransformer" Description="Instrument transformers are high accuracy class electrical devices used to isolate or transform voltage or current levels. The main function of instrument transformers is to operate instruments or metering from high voltage or high current circuits, safely isolating secondary control circuitry from the high voltages or currents. Combination instrument transformers are metering voltage." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcFlowInstrument/VOLTMETER,IfcFlowInstrument/COMBINED">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="AccuracyClass_32YEer4tP9EB633g5FK49p" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AccuracyGrade_3y6bNc8F56Hexr9v$dk$2L" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="RatedVoltage_2YuL_rvIv9uxXdCK0Vu7_6" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalCurrent_0sDhk0qUWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalPower_2pu16hiH1CqQv04BNgxAph" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfPhases_1BIplyxBLFfuml0KvHZ1y2" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PrimaryFrequency_1tZv40qX4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PrimaryVoltage_1Txac0qX4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SecondaryFrequency_1_7WY0qX4HuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SecondaryVoltage_1ZIvG0qX4HuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2VWFE0qXKHuO00025QrE$V" Name="Pset_WallCommon" Description="Properties common to the definition of all occurrences of IfcWall." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcWall">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_2moW00qXKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AcousticRating_31UdO0qXKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FireRating_39EXg0qXKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Combustible_3Fo980qXKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SurfaceSpreadOfFlame_3MLmc0qXKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ThermalTransmittance_3U5gu0qXKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsExternal_3Yss80qXKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LoadBearing_3nmXI0qXKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ExtendToStructure_3g0d00qXKHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Compartmentation_3vWRa0qXKHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="01GLs0qXOHuO00025QrE$V" Name="Pset_Warranty" Description="An assurance given by the seller or provider of an artefact that the artefact is without defects and will operate as described for a defined period of time without failure and that if a defect does arise during that time, that it will be corrected by the seller or provider." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcElement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="WarrantyIdentifier_08Q6k0qXOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WarrantyStartDate_0EzkC0qXOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsExtendedWarranty_0PiNW0qXOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WarrantyPeriod_0Ws8O0qXOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WarrantyContent_0gOUu0qXOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PointOfContact_0cDT20qXOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Exclusions_0my6M0qXOHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0tVjq0qXOHuO00025QrE$V" Name="Pset_WasteTerminalTypeCommon" Description="Common properties for waste terminals." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcWasteTerminal">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_12qWY0qXOHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1LJ480qXOHuO00025QrE$V" Name="Pset_WasteTerminalTypeFloorTrap" Description="Pipe fitting, set into the floor, that retains liquid to prevent the passage of foul air." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcWasteTerminal/FLOORTRAP">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalBodyLength_1QgOo0qXOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalBodyWidth_1Zcbu0qXOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalBodyDepth_1hyfa0qXOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsForSullageWater_1rV040qXOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SpilloverLevel_1yemy0qXOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TrapType_25a_20qXOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasStrainer_2L4oc0qXOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OutletConnectionSize_2SEZU0qXOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InletPatternType_2cN3O0qXOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InletConnectionSize_34APi0qXOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoverLength_3DimC0qXOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoverWidth_3MezI0qXOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoverMaterial_3VbAO0qXOHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3ZmCE0qXOHuO00025QrE$V" Name="Pset_WasteTerminalTypeFloorWaste" Description="Pipe fitting, set into the floor, that collects waste water and discharges it to a separate trap." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcWasteTerminal/FLOORWASTE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalBodyLength_1QgOo0qXOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalBodyWidth_1Zcbu0qXOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalBodyDepth_1hyfa0qXOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OutletConnectionSize_03y8A0qXSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoverLength_3DimC0qXOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoverWidth_3MezI0qXOHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0XlUU0qXSHuO00025QrE$V" Name="Pset_WasteTerminalTypeGullySump" Description="Pipe fitting or assembly of fittings to receive surface water or waste water, fitted with a grating or sealed cover." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcWasteTerminal/GULLYSUMP">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalSumpLength_0cWfk0qXSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalSumpWidth_0m30E0qXSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalSumpDepth_0uP3w0qXSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GullyType_137jE0qXSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TrapType_1GEyA0qXSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OutletConnectionSize_1WKw80qXSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BackInletPatternType_1ftGe0qXSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InletConnectionSize_34APi0qXOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoverLength_3DimC0qXOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoverWidth_3MezI0qXOHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2bTzG0qXSHuO00025QrE$V" Name="Pset_WasteTerminalTypeGullyTrap" Description="Pipe fitting or assembly of fittings to receive surface water or waste water, fitted with a grating or sealed cover and discharging through a trap (BS6100 330 3504 modified)" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcWasteTerminal/GULLYTRAP">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalBodyLength_1QgOo0qXOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalBodyWidth_1Zcbu0qXOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalBodyDepth_1hyfa0qXOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GullyType_382Uq0qXSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasStrainer_3LltA0qXSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TrapType_3TVnS0qXSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OutletConnectionSize_3iPSc0qXSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="BackInletPatternType_3qlWI0qXSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InletConnectionSize_34APi0qXOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoverLength_3DimC0qXOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoverWidth_3MezI0qXOHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0fobS0qXWHuO00025QrE$V" Name="Pset_WasteTerminalTypeRoofDrain" Description="Pipe fitting, set into the roof, that collects rainwater for discharge into the rainwater system." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcWasteTerminal/ROOFDRAIN">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalBodyLength_1QgOo0qXOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalBodyWidth_1Zcbu0qXOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalBodyDepth_1hyfa0qXOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OutletConnectionSize_16Pey0qXWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoverLength_3DimC0qXOHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CoverWidth_3MezI0qXOHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1XEGE0qXWHuO00025QrE$V" Name="Pset_WasteTerminalTypeWasteDisposalUnit" Description="Electrically operated device that reduces kitchen or other waste into fragments small enough to be flushed into a drainage system." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcWasteTerminal/WASTEDISPOSALUNIT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="DrainConnectionSize_1b$RU0qXWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OutletConnectionSize_1kLVA0qXWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalDepth_0HZnE0qUaHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1$dly0qXWHuO00025QrE$V" Name="Pset_WasteTerminalTypeWasteTrap" Description="Pipe fitting, set adjacent to a sanitary terminal, that retains liquid to prevent the passage of foul air." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcWasteTerminal/WASTETRAP">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="WasteTrapType_23ono0qXWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OutletConnectionSize_2GJtK0qXWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InletConnectionSize_34APi0qXOHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1F1Qpglir5Hf6lSH4kYL2d" Name="Pset_WaterStratumCommon" Description="Properties expressing the composition and any variability in the height of the body of water. Ranges are non-negative describing a spread." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcGeotechnicalStratum/WATER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="AnnualRange_1DcgPdRF13CubHGpnM9oNE" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AnnualTrend_3akVvrLBLDmhqfr5tZOBIO" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsFreshwater_1KdzyKr5b5KxvuHaCdKWAs" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SeicheRange_0ZDnfixqv4xRd7BBGSw4Uy" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TidalRange_3Ekqmkl8vDvOb4TiripBma" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WaveRange_3YT7H981H8GBd3yxDEZVD_" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="02CQn3JBnFBBwFd98ftvbY" Name="Pset_Width" Description="Specifies the general properties for a Width event." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcReferent/WIDTHEVENT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Side_1IWqwe1DT37ObnUgQI07BF" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TransitionWidth_1gW6HLbJfFTQ9qh9wdhLS7" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NominalWidth_2YZfyYRY1Aa9bsWGvZEaNq" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2YCHW0qXWHuO00025QrE$V" Name="Pset_WindowCommon" Description="Properties common to the definition of all occurrences of Window." TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcWindow">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Status_2iwwq0qXWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="AcousticRating_2vS0M0qXWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FireRating_2$$dq0qXWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SecurityRating_36ZFI0qXWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsExternal_3D6sm0qXWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Infiltration_3J4Kq0qXWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ThermalTransmittance_3ORfU0qXWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GlazingAreaFraction_3TCqk0qXWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasSillExternal_3ZmSC0qXWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasSillInternal_3gwD40qXWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HasDrive_3og7M0qXWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SmokeStop_3vpuE0qXWHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FireExit_00NVi0qXaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WaterTightnessRating_3f9JFpf_H1OPQjaZ_kufwM" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MechanicalLoadRating_1zjL_IETfD48CCr23pePYC" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WindLoadRating_1cI8AXMuf208Vs_0Pmo_8B" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3fuHThgaTBce4LpoYrpsL1" Name="Pset_WindowLiningProperties" Description="Properties of the window lining.

&gt; HISTORY&amp;nbsp; New property set in IFC4.3.2.0 to replace the entity IfcWindowLiningProperties" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcMember,IfcWindow">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="LiningDepth_1atVjJ$Sv83QJrcnVw6dEN" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LiningThickness_2F6K$8L5H9ffpQ$GwVOHM9" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TransomThickness_1HhMZXQO53UghvJldSghYj" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MullionThickness_0JOZR$$rr36wx2ZT$auLC5" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FirstTransomOffset_0bwI_yex59aARczKSEUAUL" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SecondTransomOffset_2kBLHfMdz1sR5512bDOKd_" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FirstMullionOffset_3EXrkSznnAZeQvW3rVzop0" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SecondMullionOffset_03UAKEgVLDQg8tMaHW3vDr" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LiningOffset_043uIBEdfCSBmgT2Iqxz1k" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LiningToPanelOffsetX_2qOaLgNMvDYAhH_qO9ORRY" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LiningToPanelOffsetY_1ROGiXiRP7GRCBWrJKxDo1" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3gMl$DmLz95xNwMv58RGC1" Name="Pset_WindowPanelProperties" Description="Properties of the window panel.

&gt; HISTORY&amp;nbsp; New property set in IFC4.3.2.0 to replace the entity IfcWindowPanelProperties" TemplateType="pset_typedrivenoverride" ApplicableEntity="IfcPlate,IfcWindow">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="OperationType_33QLs5kbX0BxppsYy98anS" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PanelPosition_0G5K7RuE12_RhCLZLW5MP4" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FrameDepth_2CF8ENszP0TfWSzgwCUWWp" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FrameThickness_2WtA1SnpvExvPSRzEemyhx" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3YvbjtHtOKf7UXyCbpBiT3" Name="Pset_WiredCommunicationPortCommon" Description="Properties used for wired communication port." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcDistributionPort/CABLE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="CommunicationStandard_23pIPVZq9A19s2K0Qc6rmz" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="MaximumTransferRate_0Az4uYaFHDRAo465uiJHuc" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="087P_0qXaHuO00025QrE$V" Name="Pset_WorkControlCommon" Description="Properties common to the definition of all occurrences of IfcWorkPlan and IfcWorkSchedule (subtypes of IfcWorkControl)." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcWorkControl">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="WorkStartTime_0Is3I0qXaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WorkFinishTime_0NdEY0qXaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WorkDayDuration_0S_ZC0qXaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WorkWeekDuration_0Yy1G0qXaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WorkMonthDuration_0djCW0qXaHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0kGp_0qXaHuO00025QrE$V" Name="Pset_ZoneCommon" Description="Properties common to the definition of all occurrences of IfcZone." TemplateType="pset_occurrencedriven" ApplicableEntity="IfcZone">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Reference_00pQO0qSSHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="IsExternal_0e$iimlYf0nf_mS3leF5wV" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossPlannedArea_3aRdaISbH6VwiKDVpXGI6$" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetPlannedArea_30x9qx_FP9kRuQ6ZwfPT1O" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PubliclyAccessible_1AHk40qXaHuO00025QrE$V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="HandicapAccessible_1HRUy0qXaHuO00025QrE$V" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
			</RelatedDefinitions>
		</IfcRelDeclares>
		<IfcRelDeclares GlobalId="1$c0OOaRDF_OBDoEs$xzcD" Name="Quantities">
			<RelatedDefinitions>
				<IfcSimplePropertyTemplate id="Area_0ghx$p4BP9bPO6p1adKSEF" GlobalId="0ghx$p4BP9bPO6p1adKSEF" Name="Area" Description="Calculated area for the object.

Total area of the outer lining of the window." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="Area_1cEbPpN7L4E8Pc7CR8aDZC" GlobalId="1cEbPpN7L4E8Pc7CR8aDZC" Name="Area" Description="Calculated area for the object.

Total area of the outer lining of the door." TemplateType="q_area" />
				<IfcSimplePropertyTemplate GlobalId="1CnNsFYBT6$AemE3IaDxL7" Name="Area" Description="Calculated area for the object." TemplateType="q_area" />
				<IfcSimplePropertyTemplate GlobalId="1CnNsFYBT6$AemE3IaDxL7" Name="Area" Description="Calculated area for the object." TemplateType="q_area" />
				<IfcSimplePropertyTemplate GlobalId="1CnNsFYBT6$AemE3IaDxL7" Name="Area" Description="Calculated area for the object." TemplateType="q_area" />
				<IfcSimplePropertyTemplate GlobalId="1CnNsFYBT6$AemE3IaDxL7" Name="Area" Description="Calculated area for the object." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="Area_1CnNsFYBT6$AemE3IaDxL7" GlobalId="1CnNsFYBT6$AemE3IaDxL7" Name="Area" Description="Calculated area for the object." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="Area_1WROcqqYjDCOj4JQqqzQwC" GlobalId="1WROcqqYjDCOj4JQqqzQwC" Name="Area" Description="Calculated area for the object.

Actual area of upper surface of shape." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="Area_1Z0opsKy51wvKZDpfJdCc_" GlobalId="1Z0opsKy51wvKZDpfJdCc_" Name="Area" Description="Calculated area for the object.

Area of the opening as viewed by an elevation view (for wall openings) or as viewed by a ground floor view (for slab openings)." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="Area_30mgAbQ1T07OVkS7olRIhF" GlobalId="30mgAbQ1T07OVkS7olRIhF" Name="Area" Description="Calculated area for the object.

Area represented, if lower edge of stratum known." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="Area_3oeSf80G93jhm$lrcvCmdP" GlobalId="3oeSf80G93jhm$lrcvCmdP" Name="Area" Description="Calculated area for the object.

Area of the projection as viewed by an elevation view (for wall projections) or as viewed by a ground floor view (for slab projections)." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="CompactedVolume_1clL3F_GzEROzZL0CFLOfa" GlobalId="1clL3F_GzEROzZL0CFLOfa" Name="CompactedVolume" Description="Volume of the earthworks when finished and compacted in place." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="Count_3CXRmexyLE4xZy3hpRnxmb" GlobalId="3CXRmexyLE4xZy3hpRnxmb" Name="Count" Description="Total count of reinforcing items." TemplateType="q_count" />
				<IfcSimplePropertyTemplate id="CrossSectionArea_0emE4jyCbE2fJiXgNRE_O9" GlobalId="0emE4jyCbE2fJiXgNRE_O9" Name="CrossSectionArea" Description="Total area of the cross section (or profile) of the object." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="CrossSectionArea_0PPnhNUJTDPeNa7OZnh4ij" GlobalId="0PPnhNUJTDPeNa7OZnh4ij" Name="CrossSectionArea" Description="Total area of the cross section (or profile) of the object." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="CrossSectionArea_0uyuKqXOz1N8mN8NTuQ33t" GlobalId="0uyuKqXOz1N8mN8NTuQ33t" Name="CrossSectionArea" Description="Total area of the cross section (or profile) of the object." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="CrossSectionArea_0vA4m$lVzAix3yMfG26YjY" GlobalId="0vA4m$lVzAix3yMfG26YjY" Name="CrossSectionArea" Description="Total area of the cross section (or profile) of the object." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="CrossSectionArea_1BWpnfBwb1k82WvJ6vFVRf" GlobalId="1BWpnfBwb1k82WvJ6vFVRf" Name="CrossSectionArea" Description="The cross section area of the arch element." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="CrossSectionArea_1CJ9V2eIP2VOxFOXznhRyr" GlobalId="1CJ9V2eIP2VOxFOXznhRyr" Name="CrossSectionArea" Description="Total area of the cross section (or profile) of the object." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="CrossSectionArea_2$G4u$rCL82vYqsTtwoWn4" GlobalId="2$G4u$rCL82vYqsTtwoWn4" Name="CrossSectionArea" Description="Total area of the cross section (or profile) of the object." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="CrossSectionArea_3azvi2X2n83u27ua2yTjY7" GlobalId="3azvi2X2n83u27ua2yTjY7" Name="CrossSectionArea" Description="Total area of the cross section (or profile) of the object." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="Depth_1AXq7x3FH3sAkrb38n1WIf" GlobalId="1AXq7x3FH3sAkrb38n1WIf" Name="Depth" Description="The depth of the object.

Depth (or thickness) of the opening, in case of openings it shall be identical to the width (or thickness) of the voided element, in case of recesses it shall be less. Only provided, if the depth is constant." TemplateType="q_length" />
				<IfcSimplePropertyTemplate GlobalId="1EfY1EUxjCYfMfDim4N8cC" Name="Depth" Description="The depth of the object.

Depth (one direction of the non-projected foot print area) of the slab. It shall only be provided, if the slab is rectangular.
&gt;NOTE&amp;nbsp; Also referred to as width, but not to be confused with the &quot;Width&quot; quantity, that denotes the thickness in the context of the slab." TemplateType="q_length" />
				<IfcSimplePropertyTemplate GlobalId="1EfY1EUxjCYfMfDim4N8cC" Name="Depth" Description="The depth of the object.

Depth (one direction of the non-projected foot print area) of the slab. It shall only be provided, if the slab is rectangular.
&gt;NOTE&amp;nbsp; Also referred to as width, but not to be confused with the &quot;Width&quot; quantity, that denotes the thickness in the context of the slab." TemplateType="q_length" />
				<IfcSimplePropertyTemplate GlobalId="1EfY1EUxjCYfMfDim4N8cC" Name="Depth" Description="The depth of the object.

Depth (one direction of the non-projected foot print area) of the slab. It shall only be provided, if the slab is rectangular.
&gt;NOTE&amp;nbsp; Also referred to as width, but not to be confused with the &quot;Width&quot; quantity, that denotes the thickness in the context of the slab." TemplateType="q_length" />
				<IfcSimplePropertyTemplate GlobalId="1EfY1EUxjCYfMfDim4N8cC" Name="Depth" Description="The depth of the object.

Depth (one direction of the non-projected foot print area) of the slab. It shall only be provided, if the slab is rectangular.
&gt;NOTE&amp;nbsp; Also referred to as width, but not to be confused with the &quot;Width&quot; quantity, that denotes the thickness in the context of the slab." TemplateType="q_length" />
				<IfcSimplePropertyTemplate GlobalId="1EfY1EUxjCYfMfDim4N8cC" Name="Depth" Description="The depth of the object.

Depth (one direction of the non-projected foot print area) of the slab. It shall only be provided, if the slab is rectangular.
&gt;NOTE&amp;nbsp; Also referred to as width, but not to be confused with the &quot;Width&quot; quantity, that denotes the thickness in the context of the slab." TemplateType="q_length" />
				<IfcSimplePropertyTemplate GlobalId="1EfY1EUxjCYfMfDim4N8cC" Name="Depth" Description="The depth of the object.

Depth (one direction of the non-projected foot print area) of the slab. It shall only be provided, if the slab is rectangular.
&gt;NOTE&amp;nbsp; Also referred to as width, but not to be confused with the &quot;Width&quot; quantity, that denotes the thickness in the context of the slab." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Depth_1EfY1EUxjCYfMfDim4N8cC" GlobalId="1EfY1EUxjCYfMfDim4N8cC" Name="Depth" Description="The depth of the object.

Depth (one direction of the non-projected foot print area) of the slab. It shall only be provided, if the slab is rectangular.
&gt;NOTE&amp;nbsp; Also referred to as width, but not to be confused with the &quot;Width&quot; quantity, that denotes the thickness in the context of the slab." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Depth_3RJBqFyPr5BuHqJx2YiXLV" GlobalId="3RJBqFyPr5BuHqJx2YiXLV" Name="Depth" Description="The depth of the object.

Indicates the depth of the element." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Diameter_0vS54g5YD0D8XXzjqMTI8V" GlobalId="0vS54g5YD0D8XXzjqMTI8V" Name="Diameter" Description="The Diameter of the object." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="EavesHeight_3fzA40seP3xRirGVCr9Rg5" GlobalId="3fzA40seP3xRirGVCr9Rg5" Name="EavesHeight" Description="Standard net height of this storey, from the top surface of the construction floor, to the bottom surface of the construction floor or roof above. Only provided is there is a constant height." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="FinishCeilingHeight_1vYXYSNGLCGBg4RxwFeBW6" GlobalId="1vYXYSNGLCGBg4RxwFeBW6" Name="FinishCeilingHeight" Description="Height of the suspended ceiling (from top of flooring to the bottom of the suspended ceiling). To be provided only if the space has a suspended ceiling with constant height." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="FinishFloorHeight_2O2lcrTij5CvLysWdIXQ2z" GlobalId="2O2lcrTij5CvLysWdIXQ2z" Name="FinishFloorHeight" Description="Height of the flooring (from base slab without flooring to the flooring height). To be provided only if the space has a constant flooring height." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="FootPrintArea_2$0cTYdvf6QO8z1nvVIBpB" GlobalId="2$0cTYdvf6QO8z1nvVIBpB" Name="FootPrintArea" Description="Gross area of the site covered by the building(s)." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="FootPrintArea_340fmI0CnBFRkREE87BmUJ" GlobalId="340fmI0CnBFRkREE87BmUJ" Name="FootPrintArea" Description="Gross area of the site covered by the building(s)." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="GrossArea_07WxT01B12WP6OkgfBTD0k" GlobalId="07WxT01B12WP6OkgfBTD0k" Name="GrossArea" Description="Gross Area of the object. Openings, recesses, projections and cut-outs are not taken into account.

Including the outer frame." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="GrossArea_1v7Z5Yk4T0fu61b7WfpuHO" GlobalId="1v7Z5Yk4T0fu61b7WfpuHO" Name="GrossArea" Description="Gross Area of the object. Openings, recesses, projections and cut-outs are not taken into account.

Sum of all gross areas of the covering facing the space." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="GrossArea_2E$UHt0Ij2bhNKlWZRgc6b" GlobalId="2E$UHt0Ij2bhNKlWZRgc6b" Name="GrossArea" Description="Gross Area of the object. Openings, recesses, projections and cut-outs are not taken into account.

Total area of the ramp flight (not the projected area). Only given, if the element is prismatic." TemplateType="q_area" />
				<IfcSimplePropertyTemplate GlobalId="2xt4x2$lzD8wZCrac3MEZ0" Name="GrossArea" Description="Gross Area of the object. Openings, recesses, projections and cut-outs are not taken into account.

Indicates the extruded area of the element. Only given, if the element is prismatic." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="GrossArea_2xt4x2$lzD8wZCrac3MEZ0" GlobalId="2xt4x2$lzD8wZCrac3MEZ0" Name="GrossArea" Description="Gross Area of the object. Openings, recesses, projections and cut-outs are not taken into account.

Indicates the extruded area of the element. Only given, if the element is prismatic." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="GrossArea_2ZKkm9Tab4_QDxvaNB3E7K" GlobalId="2ZKkm9Tab4_QDxvaNB3E7K" Name="GrossArea" Description="Gross Area of the object. Openings, recesses, projections and cut-outs are not taken into account.

Indicates the extruded area of the element. Only given, if the element is prismatic." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="GrossArea_3AlAzdg6P3kOXDDJ48Kvdy" GlobalId="3AlAzdg6P3kOXDDJ48Kvdy" Name="GrossArea" Description="Gross Area of the object. Openings, recesses, projections and cut-outs are not taken into account.

Measured in horizontal projections." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="GrossArea_3V2OMyAGXDUOZ$12fLJgCr" GlobalId="3V2OMyAGXDUOZ$12fLJgCr" Name="GrossArea" Description="Gross Area of the object. Openings, recesses, projections and cut-outs are not taken into account.

Indicates the outer surface of the roof and the sum of all roof slab gross areas." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="GrossCeilingArea_0l3_qgbX13XAuy5XMUIgXf" GlobalId="0l3_qgbX13XAuy5XMUIgXf" Name="GrossCeilingArea" Description="Sum of all ceiling areas of the space. It includes the area covered by elementsinside the space (columns, inner walls, etc.). The ceiling area is the real (and not the projected) area (e.g. in case of sloped ceilings)." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="GrossCrossSectionArea_0CTO01q$f9S92svrhALSXK" GlobalId="0CTO01q$f9S92svrhALSXK" Name="GrossCrossSectionArea" Description="Area of the cross section.

Including the pipe fitting itself and the interior flow space." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="GrossCrossSectionArea_1$PKD3pIz8huUfNLJLdqeC" GlobalId="1$PKD3pIz8huUfNLJLdqeC" Name="GrossCrossSectionArea" Description="Area of the cross section.

Including the pipe itself and the interior flow space." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="GrossCrossSectionArea_3V84HqO9P4GQ8WTeEY_9bp" GlobalId="3V84HqO9P4GQ8WTeEY_9bp" Name="GrossCrossSectionArea" Description="Area of the cross section.

Including the duct itself and the interior flow space." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="GrossCrossSectionArea_3Y4GBXe0vDmAgrj3olDdVZ" GlobalId="3Y4GBXe0vDmAgrj3olDdVZ" Name="GrossCrossSectionArea" Description="Area of the cross section.

At the inlet, including the duct fitting itself and the interior flow space." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="GrossFloorArea_2$BKrxu3X3_O8KrqJC$E6B" GlobalId="2$BKrxu3X3_O8KrqJC$E6B" Name="GrossFloorArea" Description="Sum of all gross floor areas within the spatial structure element.

Includes the area of construction elements within the building. May be provided in addition to the quantities of the spaces and the construction elements assigned to the building. In case of inconsistencies, the individual quantities of spaces and construction elements take precedence." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="GrossFloorArea_3fve5N$vz0P8eIQjIdXbUs" GlobalId="3fve5N$vz0P8eIQjIdXbUs" Name="GrossFloorArea" Description="Sum of all gross floor areas within the spatial structure element.

Includes the area covered by elements inside the space (columns, inner walls, etc.) and excludes the area covered by wall claddings." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="GrossFloorArea_3WwOtqsUDESuFkdurgxsdW" GlobalId="3WwOtqsUDESuFkdurgxsdW" Name="GrossFloorArea" Description="Sum of all gross floor areas within the spatial structure element.

Includes the area of construction elements within the building storey. May be provided in addition to the quantities of the spaces and the construction elements assigned to the storey. In case of inconsistencies, the individual quantities of spaces and construction elements take precedence." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="GrossFootPrintArea_0P10Tj2OL2Wv_h8X9BES4K" GlobalId="0P10Tj2OL2Wv_h8X9BES4K" Name="GrossFootPrintArea" Description="Area of the wall as viewed by a ground floor view, not taking any wall modifications (like recesses) into account. It is also referred to as the foot print of the wall." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="GrossHeight_2c3FJy8d519BbNZUzYQ6j8" GlobalId="2c3FJy8d519BbNZUzYQ6j8" Name="GrossHeight" Description="Standard gross height of this storey, from the top surface of the construction floor, to the top surface of the construction floor or roof above. Only provided is there is a constant height." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="GrossPerimeter_0GKCFgoO9ArwXCKMOoo8xB" GlobalId="0GKCFgoO9ArwXCKMOoo8xB" Name="GrossPerimeter" Description="Gross perimeter at the outer contour of the object.

Measured at floor level with all sides of the space, including those parts of the perimeter that are created by virtual boundaries and openings (like doors)." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="GrossPerimeter_3ju92XNCL9te0aUSyUzuHf" GlobalId="3ju92XNCL9te0aUSyUzuHf" Name="GrossPerimeter" Description="Gross perimeter at the outer contour of the object.

Without taking interior slab openings into account." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="GrossPerimeter_3kV1CSxXX7280RBRNjvyoq" GlobalId="3kV1CSxXX7280RBRNjvyoq" Name="GrossPerimeter" Description="Gross perimeter at the outer contour of the object.

Measured in horizontal projection." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="GrossSideArea_1zC$OvtlX2yx3GZJuKLxl$" GlobalId="1zC$OvtlX2yx3GZJuKLxl$" Name="GrossSideArea" Description="Area of the wall as viewed by an elevation view of the middle plane of the wall. It does not take into account any wall modifications (such as openings)." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="GrossSideArea_3T7_AKruz0TBm3ToQt0Naj" GlobalId="3T7_AKruz0TBm3ToQt0Naj" Name="GrossSideArea" Description="Area of the wall as viewed by an elevation view of the middle plane of the wall. It does not take into account any wall modifications (such as openings)." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="GrossSurfaceArea_0hLLA7UuvCVPodj1bFWFtl" GlobalId="0hLLA7UuvCVPodj1bFWFtl" Name="GrossSurfaceArea" Description="Total gross area of the object, normally generated as perimeter * length + 2 * cross section area. It is the sum of OuterSurfaceArea + (2 x CrossSectionArea) and shall only be given, if the OuterSurfaceArea and CrossSectionArea cannot be established separately." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="GrossSurfaceArea_11MDrBp2P3uAraI7SKsVMq" GlobalId="11MDrBp2P3uAraI7SKsVMq" Name="GrossSurfaceArea" Description="Total gross area of the object, normally generated as perimeter * length + 2 * cross section area. It is the sum of OuterSurfaceArea + (2 x CrossSectionArea) and shall only be given, if the OuterSurfaceArea and CrossSectionArea cannot be established separately." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="GrossSurfaceArea_120Q7UCrL28efVUqFX0kQ2" GlobalId="120Q7UCrL28efVUqFX0kQ2" Name="GrossSurfaceArea" Description="Total gross area of the object, normally generated as perimeter * length + 2 * cross section area. It is the sum of OuterSurfaceArea + (2 x CrossSectionArea) and shall only be given, if the OuterSurfaceArea and CrossSectionArea cannot be established separately." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="GrossSurfaceArea_184cNPB754Ig7C0fjvOfSD" GlobalId="184cNPB754Ig7C0fjvOfSD" Name="GrossSurfaceArea" Description="Total gross area of the object, normally generated as perimeter * length + 2 * cross section area. It is the sum of OuterSurfaceArea + (2 x CrossSectionArea) and shall only be given, if the OuterSurfaceArea and CrossSectionArea cannot be established separately." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="GrossSurfaceArea_20Esv0DRX5ygqyDjBoU9UK" GlobalId="20Esv0DRX5ygqyDjBoU9UK" Name="GrossSurfaceArea" Description="Total gross area of the object, normally generated as perimeter * length + 2 * cross section area. It is the sum of OuterSurfaceArea + (2 x CrossSectionArea) and shall only be given, if the OuterSurfaceArea and CrossSectionArea cannot be established separately." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="GrossSurfaceArea_2p6SNTq5v2DwZaZ4YwQmqm" GlobalId="2p6SNTq5v2DwZaZ4YwQmqm" Name="GrossSurfaceArea" Description="Total gross area of the object, normally generated as perimeter * length + 2 * cross section area. It is the sum of OuterSurfaceArea + (2 x CrossSectionArea) and shall only be given, if the OuterSurfaceArea and CrossSectionArea cannot be established separately." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="GrossSurfaceArea_37jdwMgmf35wihgfyazkKB" GlobalId="37jdwMgmf35wihgfyazkKB" Name="GrossSurfaceArea" Description="Total gross area of the object, normally generated as perimeter * length + 2 * cross section area. It is the sum of OuterSurfaceArea + (2 x CrossSectionArea) and shall only be given, if the OuterSurfaceArea and CrossSectionArea cannot be established separately.

Total gross surface area of the element before applying product-level geometric features such as openings and projections." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="GrossVolume_0eJM_AYGPDGBeQZ_tEdSxG" GlobalId="0eJM_AYGPDGBeQZ_tEdSxG" Name="GrossVolume" Description="Total gross volume of the object. Openings, recesses, enclosed objects and projections are not taken into account." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="GrossVolume_14nohS8fbDaRUpazUdVSy5" GlobalId="14nohS8fbDaRUpazUdVSy5" Name="GrossVolume" Description="Total gross volume of the object. Openings, recesses, enclosed objects and projections are not taken into account." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate GlobalId="14RqdfQXT4qQ82_ZE93nfB" Name="GrossVolume" Description="Total gross volume of the object. Openings, recesses, enclosed objects and projections are not taken into account." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate GlobalId="14RqdfQXT4qQ82_ZE93nfB" Name="GrossVolume" Description="Total gross volume of the object. Openings, recesses, enclosed objects and projections are not taken into account." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="GrossVolume_14RqdfQXT4qQ82_ZE93nfB" GlobalId="14RqdfQXT4qQ82_ZE93nfB" Name="GrossVolume" Description="Total gross volume of the object. Openings, recesses, enclosed objects and projections are not taken into account." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="GrossVolume_1jjfV2W558hg0ihu$no3sS" GlobalId="1jjfV2W558hg0ihu$no3sS" Name="GrossVolume" Description="Total gross volume of the object. Openings, recesses, enclosed objects and projections are not taken into account." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="GrossVolume_1yO7vl54P1TQOXcUVdO$xX" GlobalId="1yO7vl54P1TQOXcUVdO$xX" Name="GrossVolume" Description="Total gross volume of the object. Openings, recesses, enclosed objects and projections are not taken into account." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="GrossVolume_2051xg09X1z8mAolsFi5do" GlobalId="2051xg09X1z8mAolsFi5do" Name="GrossVolume" Description="Total gross volume of the object. Openings, recesses, enclosed objects and projections are not taken into account.

Sum of all gross volumes of spaces enclosed. It includes the volumes of construction elements within the element. May be provided in addition to the quantities of the spaces and the construction elements assigned to the element. In case of inconsistencies, the individual quantities of spaces and construction elements take precedence." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="GrossVolume_23Oh8d2BTDXxVHWoDjmHE8" GlobalId="23Oh8d2BTDXxVHWoDjmHE8" Name="GrossVolume" Description="Total gross volume of the object. Openings, recesses, enclosed objects and projections are not taken into account." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="GrossVolume_27rr6u2MD8fw7H8mqNEcYU" GlobalId="27rr6u2MD8fw7H8mqNEcYU" Name="GrossVolume" Description="Total gross volume of the object. Openings, recesses, enclosed objects and projections are not taken into account." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="GrossVolume_2lARuJES14dQ4cw2yiAyV3" GlobalId="2lARuJES14dQ4cw2yiAyV3" Name="GrossVolume" Description="Total gross volume of the object. Openings, recesses, enclosed objects and projections are not taken into account." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="GrossVolume_2vCxWbK8v4KO8xK1S_xlsP" GlobalId="2vCxWbK8v4KO8xK1S_xlsP" Name="GrossVolume" Description="Total gross volume of the object. Openings, recesses, enclosed objects and projections are not taken into account.

Total gross volume of the element before applying product-level geometric features such as openings and projections." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="GrossVolume_2yvxaQH3v4S8nrMT36FEuh" GlobalId="2yvxaQH3v4S8nrMT36FEuh" Name="GrossVolume" Description="Total gross volume of the object. Openings, recesses, enclosed objects and projections are not taken into account.

Sum of all gross volumes of spaces enclosed. It includes the volumes of construction elements within the element. May be provided in addition to the quantities of the spaces and the construction elements assigned to the element. In case of inconsistencies, the individual quantities of spaces and construction elements take precedence." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="GrossVolume_30poMMOJL2rB0$xyTEd8wz" GlobalId="30poMMOJL2rB0$xyTEd8wz" Name="GrossVolume" Description="Total gross volume of the object. Openings, recesses, enclosed objects and projections are not taken into account.

Including material placed and wasted." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="GrossVolume_33_HQffm1D28GEII3cbBRn" GlobalId="33_HQffm1D28GEII3cbBRn" Name="GrossVolume" Description="Total gross volume of the object. Openings, recesses, enclosed objects and projections are not taken into account." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="GrossVolume_38iKg02F54r909_c7iOrrL" GlobalId="38iKg02F54r909_c7iOrrL" Name="GrossVolume" Description="Total gross volume of the object. Openings, recesses, enclosed objects and projections are not taken into account." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="GrossVolume_3OYqYJKmPDBO6hW164LcIC" GlobalId="3OYqYJKmPDBO6hW164LcIC" Name="GrossVolume" Description="Total gross volume of the object. Openings, recesses, enclosed objects and projections are not taken into account." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="GrossVolume_3Wcqtil2n9iwS_wUu2QT78" GlobalId="3Wcqtil2n9iwS_wUu2QT78" Name="GrossVolume" Description="Total gross volume of the object. Openings, recesses, enclosed objects and projections are not taken into account." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="GrossWallArea_0Rz99oZ4vFMQhYwpYjPCL_" GlobalId="0Rz99oZ4vFMQhYwpYjPCL_" Name="GrossWallArea" Description="Sum of all wall (and other vertically bounding elements, like columns) areas bounded by the space. It includes the area covered by elements inside the wall area (doors, windows, other openings, etc.)." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="GrossWeight_00ihrh0tn1tBXJu$zIJzjG" GlobalId="00ihrh0tn1tBXJu$zIJzjG" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_01dCdA2zL9Sf_o9HgyD5uh" GlobalId="01dCdA2zL9Sf_o9HgyD5uh" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_05375LeRf2auX0OD69UDJ$" GlobalId="05375LeRf2auX0OD69UDJ$" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses.

Not including contained fluid." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_07h3fAPAn46BMgkN7z3M_c" GlobalId="07h3fAPAn46BMgkN7z3M_c" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_07xyOpYN1ENPlFP$7E14qH" GlobalId="07xyOpYN1ENPlFP$7E14qH" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_0BJRbPAbfDivUkRgI7mLpw" GlobalId="0BJRbPAbfDivUkRgI7mLpw" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses.

Not including contained fluid." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_0GI$hJlcr1_OvDjxkjhZz8" GlobalId="0GI$hJlcr1_OvDjxkjhZz8" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_0Ieqrchcb2fe7R9p1VfZHd" GlobalId="0Ieqrchcb2fe7R9p1VfZHd" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_0KoyVFQXjEcRNAUBqltG6$" GlobalId="0KoyVFQXjEcRNAUBqltG6$" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_0m9HvtmSbD2Q2B3reqlYyB" GlobalId="0m9HvtmSbD2Q2B3reqlYyB" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_0mGDb85BT0dxQniWrPEA3L" GlobalId="0mGDb85BT0dxQniWrPEA3L" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_0mov4erQL9RPHiBBypmvPU" GlobalId="0mov4erQL9RPHiBBypmvPU" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_0NZqCLyJL038dOoXtrPjvo" GlobalId="0NZqCLyJL038dOoXtrPjvo" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_0pK5JtwqjBqOGb7AJQkCo1" GlobalId="0pK5JtwqjBqOGb7AJQkCo1" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_0rA2jWN0n0yw1RyiILIi4c" GlobalId="0rA2jWN0n0yw1RyiILIi4c" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_0T$xcLLdz2ZArODjG93KwI" GlobalId="0T$xcLLdz2ZArODjG93KwI" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_0TyiBj$lL5W8Ee7G3FWcIm" GlobalId="0TyiBj$lL5W8Ee7G3FWcIm" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_0uKYqWzxn8nwtXEyQJTMaw" GlobalId="0uKYqWzxn8nwtXEyQJTMaw" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_0vSG9GRDbD5AbNcFYXHyw5" GlobalId="0vSG9GRDbD5AbNcFYXHyw5" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_0w_kKl$I9Bo84EzPE$16E9" GlobalId="0w_kKl$I9Bo84EzPE$16E9" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_0W1Al0vZn0Vh8zIAJto8ij" GlobalId="0W1Al0vZn0Vh8zIAJto8ij" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_0WGCvpd9TC1hpTeTokrgzm" GlobalId="0WGCvpd9TC1hpTeTokrgzm" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_0WIMBK5rbFRwB247cORYJz" GlobalId="0WIMBK5rbFRwB247cORYJz" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_0x6znX0LLALQF8nzpFwsoX" GlobalId="0x6znX0LLALQF8nzpFwsoX" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_0xfN4KKdn3yvuyD3Xzzt16" GlobalId="0xfN4KKdn3yvuyD3Xzzt16" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses.

Not including contained fluid." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_0ZKKf9O7rAOurEWxXgLOOy" GlobalId="0ZKKf9O7rAOurEWxXgLOOy" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_14fujPcAX9KQOvAie9AvUO" GlobalId="14fujPcAX9KQOvAie9AvUO" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_1auc77qC52AhlGJuEOoQbg" GlobalId="1auc77qC52AhlGJuEOoQbg" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_1Dk$VgoEfASfOYW7$rDZlP" GlobalId="1Dk$VgoEfASfOYW7$rDZlP" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_1InDYDQ0bF4887_MZria4x" GlobalId="1InDYDQ0bF4887_MZria4x" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_1JO2FNSBD94wMmbjBm7Ry1" GlobalId="1JO2FNSBD94wMmbjBm7Ry1" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses.

Including material placed and wasted." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_1lMSRiVnL6uv6REGn4e0Im" GlobalId="1lMSRiVnL6uv6REGn4e0Im" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_1oiTCHhz51wBmEpe_mOLJW" GlobalId="1oiTCHhz51wBmEpe_mOLJW" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_1pB5sgAv56UxQS0smeQqw5" GlobalId="1pB5sgAv56UxQS0smeQqw5" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_1SeGGNb75AXfTrOHr7Myp9" GlobalId="1SeGGNb75AXfTrOHr7Myp9" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_1SLwhC5or6kR8QJW$2Ppdn" GlobalId="1SLwhC5or6kR8QJW$2Ppdn" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_1smEkXY$r3gP1FYpbiEjLd" GlobalId="1smEkXY$r3gP1FYpbiEjLd" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_1tAY9vaCvFCOduhWxgb6eA" GlobalId="1tAY9vaCvFCOduhWxgb6eA" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_1YT_g1nn98PP66gwW3cQCy" GlobalId="1YT_g1nn98PP66gwW3cQCy" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_25G6PPARz5aelYP_pgRJGa" GlobalId="25G6PPARz5aelYP_pgRJGa" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_26DiA$pC1DXQ7y1wOVBdVa" GlobalId="26DiA$pC1DXQ7y1wOVBdVa" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_28jiUHD35D2AF5FBGtoEN7" GlobalId="28jiUHD35D2AF5FBGtoEN7" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_28SdjVtSj3qQ3gvIiqeUIa" GlobalId="28SdjVtSj3qQ3gvIiqeUIa" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_2A4lBn5Xn2EQAoHY6UT1X0" GlobalId="2A4lBn5Xn2EQAoHY6UT1X0" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_2BHKqYW6f5qfS1C8h8pBXw" GlobalId="2BHKqYW6f5qfS1C8h8pBXw" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_2D$gyRToX6ifRSHPJIOPCo" GlobalId="2D$gyRToX6ifRSHPJIOPCo" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses.

Not including contained fluid." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_2d69Q1SRP8v8rWzJ07$Kdd" GlobalId="2d69Q1SRP8v8rWzJ07$Kdd" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_2J02SRun51HAwYTeufRxcY" GlobalId="2J02SRun51HAwYTeufRxcY" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_2KoN62q3fBdOzd1dky$NLy" GlobalId="2KoN62q3fBdOzd1dky$NLy" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_2kZNH8VxTCIQ$55loAyOr6" GlobalId="2kZNH8VxTCIQ$55loAyOr6" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_2LSqYKQbr9uBpg1Y1sZLZ4" GlobalId="2LSqYKQbr9uBpg1Y1sZLZ4" Name="GrossWeight" Description="Total net weight of the object without add-on parts, taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_2O4Iq5oVPAKfwTsy3SBhvP" GlobalId="2O4Iq5oVPAKfwTsy3SBhvP" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_2ReQoK7HLCnBnSyvF4LETx" GlobalId="2ReQoK7HLCnBnSyvF4LETx" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_2Ru4nYFdvDbhu6lV6WlOcT" GlobalId="2Ru4nYFdvDbhu6lV6WlOcT" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses.

Not including contained fluid." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_2T$jnrHN90jR1dfV6miZ_4" GlobalId="2T$jnrHN90jR1dfV6miZ_4" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_2wCGB$0tr1RgwfPgSrkn7b" GlobalId="2wCGB$0tr1RgwfPgSrkn7b" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_2wYRWuU9n6FwcgXHQuQT1Z" GlobalId="2wYRWuU9n6FwcgXHQuQT1Z" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_2wzjQxh5H7ZALNoJoJWAwE" GlobalId="2wzjQxh5H7ZALNoJoJWAwE" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_2XO1E_VubFKvIvNoae447X" GlobalId="2XO1E_VubFKvIvNoae447X" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses.

Not including contained fluid." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_3_haAJs21108lznLPBkIMM" GlobalId="3_haAJs21108lznLPBkIMM" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_3_YG1FBCHCqRo0R5SCOcRW" GlobalId="3_YG1FBCHCqRo0R5SCOcRW" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_38TydLycj6F8aNN0BZ7Mjn" GlobalId="38TydLycj6F8aNN0BZ7Mjn" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_39PZMMXFXETf4ONj$4IUnm" GlobalId="39PZMMXFXETf4ONj$4IUnm" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_3AKYGF6Av9qfecEq71L9Bs" GlobalId="3AKYGF6Av9qfecEq71L9Bs" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_3cW_u6Vwz3hBkTHlmfnLH4" GlobalId="3cW_u6Vwz3hBkTHlmfnLH4" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_3Izxj$rfDDDeX2r8M2eeI3" GlobalId="3Izxj$rfDDDeX2r8M2eeI3" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_3jsd$iRZPAewmF$8het2R_" GlobalId="3jsd$iRZPAewmF$8het2R_" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_3la6Kpg0XCKuqOgL4JE7p$" GlobalId="3la6Kpg0XCKuqOgL4JE7p$" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_3lrUWsH417HvsqNKqd7kb7" GlobalId="3lrUWsH417HvsqNKqd7kb7" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_3Mtbk432rEdwcRhIyj1HD9" GlobalId="3Mtbk432rEdwcRhIyj1HD9" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_3Q$qPXmMn6NRL$$A2RD36z" GlobalId="3Q$qPXmMn6NRL$$A2RD36z" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_3vrK_zBzz6xQncWDay9ia9" GlobalId="3vrK_zBzz6xQncWDay9ia9" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="GrossWeight_3WAQZKjvb4QQKwL_93u9EK" GlobalId="3WAQZKjvb4QQKwL_93u9EK" Name="GrossWeight" Description="Total Gross Weight of the object without any add-on parts and not taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="Height_0l46kxLer8ZvIAfet6uUEt" GlobalId="0l46kxLer8ZvIAfet6uUEt" Name="Height" Description="Characteristic height

Standard gross height of this building, from the top surface of the construction floor, to the top surface of the construction floor or roof above. Only provided is there is a constant height." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Height_0NXCOa3OXFE9$sWnHvmoai" GlobalId="0NXCOa3OXFE9$sWnHvmoai" Name="Height" Description="Characteristic height

Height of the opening, in case of wall openings it is the vertical dimension in case of slab openings it is one horizontal dimension. Only provided, if the area is rectangular." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Height_1hGPoGg2L09v1afkqhXBHH" GlobalId="1hGPoGg2L09v1afkqhXBHH" Name="Height" Description="Characteristic height

Total outer height of the window lining. It should only be provided, if it is a rectangular window." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Height_1KsfmdV9XDWPeiUZciB6O0" GlobalId="1KsfmdV9XDWPeiUZciB6O0" Name="Height" Description="Characteristic height

Total height of the curtain wall. It should only be provided, if it is constant along the curtain wall path." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Height_2fZo2S2rzBOhweGqI3yt36" GlobalId="2fZo2S2rzBOhweGqI3yt36" Name="Height" Description="Characteristic height

Total nominal height of the footing. It should only be provided, if it is constant." TemplateType="q_length" />
				<IfcSimplePropertyTemplate GlobalId="3jq0d8r0zBYvccpej6okcm" Name="Height" Description="Characteristic height" TemplateType="q_length" />
				<IfcSimplePropertyTemplate GlobalId="3jq0d8r0zBYvccpej6okcm" Name="Height" Description="Characteristic height" TemplateType="q_length" />
				<IfcSimplePropertyTemplate GlobalId="3jq0d8r0zBYvccpej6okcm" Name="Height" Description="Characteristic height" TemplateType="q_length" />
				<IfcSimplePropertyTemplate GlobalId="3jq0d8r0zBYvccpej6okcm" Name="Height" Description="Characteristic height" TemplateType="q_length" />
				<IfcSimplePropertyTemplate GlobalId="3jq0d8r0zBYvccpej6okcm" Name="Height" Description="Characteristic height" TemplateType="q_length" />
				<IfcSimplePropertyTemplate GlobalId="3jq0d8r0zBYvccpej6okcm" Name="Height" Description="Characteristic height" TemplateType="q_length" />
				<IfcSimplePropertyTemplate GlobalId="3jq0d8r0zBYvccpej6okcm" Name="Height" Description="Characteristic height" TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Height_3jq0d8r0zBYvccpej6okcm" GlobalId="3jq0d8r0zBYvccpej6okcm" Name="Height" Description="Characteristic height" TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Height_3WbJ7i_U9ArhOXaHfEfvFa" GlobalId="3WbJ7i_U9ArhOXaHfEfvFa" Name="Height" Description="Characteristic height

Total nominal height of the wall. It should only be provided, if it is constant along the wall path." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Height_3x$bGOprDCQgg7xK4PC4OC" GlobalId="3x$bGOprDCQgg7xK4PC4OC" Name="Height" Description="Characteristic height

Total outer height of the door lining. It should only be provided, if it is a rectangular door." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Height_3XxoA_x39CYBTbBTI6Ucc_" GlobalId="3XxoA_x39CYBTbBTI6Ucc_" Name="Height" Description="Characteristic height

Total height (from base slab without flooring to ceiling without suspended ceiling) for this space (measured from top of slab below to bottom of slab above). To be provided only if the space has a constant height." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="InnerDiameter_2rMNdLyMj5mAE00RNkEMm9" GlobalId="2rMNdLyMj5mAE00RNkEMm9" Name="InnerDiameter" Description="The actual inner diameter of the object." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="InnerSurfaceArea_1bO4eo9tXEOBFCON4r8KnZ" GlobalId="1bO4eo9tXEOBFCON4r8KnZ" Name="InnerSurfaceArea" Description="The inner surface area of the arch element." />
				<IfcSimplePropertyTemplate id="Length_0GQgOEFyz7XxNg7uky7YDi" GlobalId="0GQgOEFyz7XxNg7uky7YDi" Name="Length" Description="The length of the object.

Calculated at midpoint of cross-section, equal to the distance between inlet and outlet ports." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Length_0LFcPBJ55FxAJ9btosgfER" GlobalId="0LFcPBJ55FxAJ9btosgfER" Name="Length" Description="The length of the object.

Calculated at midpoint of cross-section and equal to the distance along the flow path from the port inlet to the port outlet. For junction fittings, it indicates the length of the longest flow path." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Length_0mnhKv2352bP05kAyx9dZS" GlobalId="0mnhKv2352bP05kAyx9dZS" Name="Length" Description="The length of the object.

Measured along the walking line." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Length_0Pplv_8rXDmfDaqsRu1pzv" GlobalId="0Pplv_8rXDmfDaqsRu1pzv" Name="Length" Description="The length of the object.

Calculated at midpoint of cross-section, equal to the distance between inlet and outlet ports." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Length_0r0CjuAFbF5ht38RfIA5VC" GlobalId="0r0CjuAFbF5ht38RfIA5VC" Name="Length" Description="The length of the object.

Along center line (even if different to the wall path)." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Length_0tSm_oibzF$hmgsUBZDeIH" GlobalId="0tSm_oibzF$hmgsUBZDeIH" Name="Length" Description="The length of the object.

Along center line (even if different to the wall path)." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Length_0wFNjuTo99Yhev5$Z803q5" GlobalId="0wFNjuTo99Yhev5$Z803q5" Name="Length" Description="The length of the object.

From the foundation (or beginning) to the top not taking into account any cut-out&apos;s or other processing features." TemplateType="q_length" />
				<IfcSimplePropertyTemplate GlobalId="12VlqG8sb7DQA2dQlUV7OR" Name="Length" Description="The length of the object." TemplateType="q_length" />
				<IfcSimplePropertyTemplate GlobalId="12VlqG8sb7DQA2dQlUV7OR" Name="Length" Description="The length of the object." TemplateType="q_length" />
				<IfcSimplePropertyTemplate GlobalId="12VlqG8sb7DQA2dQlUV7OR" Name="Length" Description="The length of the object." TemplateType="q_length" />
				<IfcSimplePropertyTemplate GlobalId="12VlqG8sb7DQA2dQlUV7OR" Name="Length" Description="The length of the object." TemplateType="q_length" />
				<IfcSimplePropertyTemplate GlobalId="12VlqG8sb7DQA2dQlUV7OR" Name="Length" Description="The length of the object." TemplateType="q_length" />
				<IfcSimplePropertyTemplate GlobalId="12VlqG8sb7DQA2dQlUV7OR" Name="Length" Description="The length of the object." TemplateType="q_length" />
				<IfcSimplePropertyTemplate GlobalId="12VlqG8sb7DQA2dQlUV7OR" Name="Length" Description="The length of the object." TemplateType="q_length" />
				<IfcSimplePropertyTemplate GlobalId="12VlqG8sb7DQA2dQlUV7OR" Name="Length" Description="The length of the object." TemplateType="q_length" />
				<IfcSimplePropertyTemplate GlobalId="12VlqG8sb7DQA2dQlUV7OR" Name="Length" Description="The length of the object." TemplateType="q_length" />
				<IfcSimplePropertyTemplate GlobalId="12VlqG8sb7DQA2dQlUV7OR" Name="Length" Description="The length of the object." TemplateType="q_length" />
				<IfcSimplePropertyTemplate GlobalId="12VlqG8sb7DQA2dQlUV7OR" Name="Length" Description="The length of the object." TemplateType="q_length" />
				<IfcSimplePropertyTemplate GlobalId="12VlqG8sb7DQA2dQlUV7OR" Name="Length" Description="The length of the object." TemplateType="q_length" />
				<IfcSimplePropertyTemplate GlobalId="12VlqG8sb7DQA2dQlUV7OR" Name="Length" Description="The length of the object." TemplateType="q_length" />
				<IfcSimplePropertyTemplate GlobalId="12VlqG8sb7DQA2dQlUV7OR" Name="Length" Description="The length of the object." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Length_12VlqG8sb7DQA2dQlUV7OR" GlobalId="12VlqG8sb7DQA2dQlUV7OR" Name="Length" Description="The length of the object." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Length_1dACFzC1n5mupC7A4jIXpl" GlobalId="1dACFzC1n5mupC7A4jIXpl" Name="Length" Description="The length of the object.

Calculated at midpoint of cross-section and equal to the distance along the flow path from the port inlet to the port outlet. For junction fittings, it indicates the length of the longest flow path." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Length_1E2FefAfrAtvyN5FmHjQ95" GlobalId="1E2FefAfrAtvyN5FmHjQ95" Name="Length" Description="The length of the object." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Length_2$G8M_eiDEgwJIrvinbXuH" GlobalId="2$G8M_eiDEgwJIrvinbXuH" Name="Length" Description="The length of the object.

Effective length sampled, if lower end of segment known" TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Length_2$jJcrH4rEGfeVtDgy1kcg" GlobalId="2$jJcrH4rEGfeVtDgy1kcg" Name="Length" Description="The length of the object.

Of upper edge of slice." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Length_21NkL6Eqj1Y9ibmbKT0sJZ" GlobalId="21NkL6Eqj1Y9ibmbKT0sJZ" Name="Length" Description="The length of the object.

Not taking into account any cut-out&apos;s or other processing features. For strip footings it is measured along the path, for other footings it is one of the horizontal dimensions. It should only be provided, if it is constant." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Length_23VJ9cbmr7Z8nLCL2Ztv7T" GlobalId="23VJ9cbmr7Z8nLCL2Ztv7T" Name="Length" Description="The length of the object.

Not taking into account any cut-out&apos;s or other processing features." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Length_25Uys$MQb2a8qWjqTa2SG7" GlobalId="25Uys$MQb2a8qWjqTa2SG7" Name="Length" Description="The length of the object.

Not taking into account any cut-out&apos;s or other processing features." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Length_2fejRsTX5CrOwvJ8uiZiDk" GlobalId="2fejRsTX5CrOwvJ8uiZiDk" Name="Length" Description="Length of the segment, calcThe length of the object.

Calculated at midpoint of cross-section, equal to the distance between inlet and outlet ports.ulated at midpoint of cross-section, equal to the distance between inlet and outlet ports." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Length_2kNfSScs5BTAVyaOQHdEQQ" GlobalId="2kNfSScs5BTAVyaOQHdEQQ" Name="Length" Description="The length of the object.

Measured along the walking line." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Length_2pjqbPAJ1C4BfN5MpqR$55" GlobalId="2pjqbPAJ1C4BfN5MpqR$55" Name="Length" Description="The length of the object." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Length_2U468iDh12lfpRdFjlDGpa" GlobalId="2U468iDh12lfpRdFjlDGpa" Name="Length" Description="The length of the object.

The axis arch length from the profile center of gravity." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Length_2XuGBfa51FBAheQBk7g7Tw" GlobalId="2XuGBfa51FBAheQBk7g7Tw" Name="Length" Description="The length of the object.

Not taking into account any cut-out&apos;s or other processing features." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Length_2z1P39Ymn4hPye8Niet8tP" GlobalId="2z1P39Ymn4hPye8Niet8tP" Name="Length" Description="The length of the object.

Calculated at midpoint of cross-section, equal to the distance between inlet and outlet ports." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Length_3HAJVhcK15aw_kd5ahVYMn" GlobalId="3HAJVhcK15aw_kd5ahVYMn" Name="Length" Description="The length of the object.

Not taking into account any cut-out&apos;s or other processing features." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Length_3khYIfZeD0OuKusADQQdov" GlobalId="3khYIfZeD0OuKusADQQdov" Name="Length" Description="The length of the object.

Only provided if rectangular." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Length_3z_1RK79zEYQlNxgE2SP3k" GlobalId="3z_1RK79zEYQlNxgE2SP3k" Name="Length" Description="The length of the object.

Not taking into account any cut-out&apos;s or other processing features." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="LengthTreatedArea_22EC_Kwwz6oPOJDIRf0AmV" GlobalId="22EC_Kwwz6oPOJDIRf0AmV" Name="LengthTreatedArea" Description="Length of treated area." TemplateType="q_length" />
				<IfcSimplePropertyTemplate GlobalId="1f8iHGSB91FBK9qA7FuE68" Name="LooseVolume" Description="Volume of the earthworks when in a loose piled state" TemplateType="q_volume" />
				<IfcSimplePropertyTemplate GlobalId="1f8iHGSB91FBK9qA7FuE68" Name="LooseVolume" Description="Volume of the earthworks when in a loose piled state" TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="LooseVolume_1f8iHGSB91FBK9qA7FuE68" GlobalId="1f8iHGSB91FBK9qA7FuE68" Name="LooseVolume" Description="Volume of the earthworks when in a loose piled state" TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="Mass_1RL9YZzxfF8OOLIYHIynpF" GlobalId="1RL9YZzxfF8OOLIYHIynpF" Name="Mass" Description="Mass represented, if lower surface of stratum known." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="NetArea_17ubdukNb0W9aXEckuuiud" GlobalId="17ubdukNb0W9aXEckuuiud" Name="NetArea" Description="Total net area of the object. Openings, recesses and cut-outs are taken into account by subtraction, projections by addition.

Indicates the extruded area of the object. Only given when prismatic." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="NetArea_184ko6bvr3dxtoDs6$yNLT" GlobalId="184ko6bvr3dxtoDs6$yNLT" Name="NetArea" Description="Total net area of the object. Openings, recesses and cut-outs are taken into account by subtraction, projections by addition.

Sum of all net areas of the covering facing the space." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="NetArea_1ByOtKo4rDs8RprEsr6YLM" GlobalId="1ByOtKo4rDs8RprEsr6YLM" Name="NetArea" Description="Total net area of the object. Openings, recesses and cut-outs are taken into account by subtraction, projections by addition.

Total net area of the outer surface of the roof. It is the suma of all roof slab net areas." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="NetArea_1Cm3Wf9gz6Pv9Yf5jcGsIz" GlobalId="1Cm3Wf9gz6Pv9Yf5jcGsIz" Name="NetArea" Description="Total net area of the object. Openings, recesses and cut-outs are taken into account by subtraction, projections by addition.

Total area of the ramp flight (not the projected area). Only given when prismatic." TemplateType="q_area" />
				<IfcSimplePropertyTemplate GlobalId="29izq2o8PDM9ZgFTCAF4ra" Name="NetArea" Description="Total net area of the object. Openings, recesses and cut-outs are taken into account by subtraction, projections by addition.

Indicates the extruded area of the object. Only given when prismatic." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="NetArea_29izq2o8PDM9ZgFTCAF4ra" GlobalId="29izq2o8PDM9ZgFTCAF4ra" Name="NetArea" Description="Total net area of the object. Openings, recesses and cut-outs are taken into account by subtraction, projections by addition.

Indicates the extruded area of the object. Only given when prismatic." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="NetCeilingArea_3yUyI6Y6r4gukTxM5fD3Dd" GlobalId="3yUyI6Y6r4gukTxM5fD3Dd" Name="NetCeilingArea" Description="Sum of all ceiling areas of the space. It excludes the area covered by elementsinside the space (columns, inner walls, etc.). The ceiling area is the real (and not the projected) area (e.g. in case of sloped ceilings)." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="NetCrossSectionArea_0KrsSEz1T1XfJ0QzSOxLHh" GlobalId="0KrsSEz1T1XfJ0QzSOxLHh" Name="NetCrossSectionArea" Description="Area of the cross section of the object.

Excluding the interior flow space." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="NetCrossSectionArea_0kVAuHyLz45AM0hLPZMgMm" GlobalId="0kVAuHyLz45AM0hLPZMgMm" Name="NetCrossSectionArea" Description="Area of the cross section of the object.

Including the pipe fitting and excluding the interior flow space." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="NetCrossSectionArea_0oC5ZHnEP5ahhXtNd1QWtv" GlobalId="0oC5ZHnEP5ahhXtNd1QWtv" Name="NetCrossSectionArea" Description="Area of the cross section of the object.

Excluding the interior flow space." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="NetCrossSectionArea_26xd6BAzbCXwSo5dPGpKlq" GlobalId="26xd6BAzbCXwSo5dPGpKlq" Name="NetCrossSectionArea" Description="Area of the cross section of the object.

Including the duct fitting and excluding the interior flow space." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="NetFloorArea_1JBcBU2tH1v8Bm7_Eqqb3T" GlobalId="1JBcBU2tH1v8Bm7_Eqqb3T" Name="NetFloorArea" Description="Sum of all net usable floor areas.

It excludes the area of construction elements within the building. May be provided in addition to the quantities of the spaces assigned to the building. In case of inconsistencies, the individual quantities of spaces take precedence." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="NetFloorArea_2L2PpHBjL5yR$QAv1NUTbm" GlobalId="2L2PpHBjL5yR$QAv1NUTbm" Name="NetFloorArea" Description="Sum of all net usable floor areas.

It excludes the area covered by elements inside the space (columns, inner walls, built-in&apos;s etc.), slab openings, or other protruding elements. Varying heights are not taking into account (i.e. no reduction for areas under a minimum headroom)." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="NetFloorArea_3xbBzAevX6Jw2IeZhyIsFb" GlobalId="3xbBzAevX6Jw2IeZhyIsFb" Name="NetFloorArea" Description="Sum of all net usable floor areas.

It excludes the area of construction elements within the building storey. May be provided in addition to the quantities of the spaces assigned to the storey. In case of inconsistencies, the individual quantities of spaces take precedence." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="NetFootPrintArea_08AeXBr_1BtfH8IkgbSECv" GlobalId="08AeXBr_1BtfH8IkgbSECv" Name="NetFootPrintArea" Description="Area of the wall as viewed by a ground floor view, taking all wall modifications (like recesses) into account. It is also referred to as the foot print of the wall." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="NetHeight_1$6dDMwur71g6f0RlcwV8j" GlobalId="1$6dDMwur71g6f0RlcwV8j" Name="NetHeight" Description="Standard net height of this storey, from the top surface of the construction floor, to the bottom surface of the construction floor or roof above. Only provided is there is a constant height." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="NetPerimeter_1iifDS_eX5VQSApD679O_R" GlobalId="1iifDS_eX5VQSApD679O_R" Name="NetPerimeter" Description="Net perimeter at the floor level of this space. It excludes those parts of the perimeter that are created by by virtual boundaries and openings (like doors). It is the measurement used for skirting boards and may include the perimeter of internal fixed objects like columns." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="NetSideArea_0FyqBJJ3P1O8EEKU9cgC1X" GlobalId="0FyqBJJ3P1O8EEKU9cgC1X" Name="NetSideArea" Description="Area of the object as viewed by an elevation view of the middle plane of the object. It does take into account all object modifications (such as openings)." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="NetSideArea_3dROH$uFj4vPNKtWkhmkoW" GlobalId="3dROH$uFj4vPNKtWkhmkoW" Name="NetSideArea" Description="Area of the object as viewed by an elevation view of the middle plane of the object. It does take into account all object modifications (such as openings)." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="NetSurfaceArea_0AxNPioRr2f8eBaIvLf9Ep" GlobalId="0AxNPioRr2f8eBaIvLf9Ep" Name="NetSurfaceArea" Description="Net surface area of the object, normally generated as perimeter * length + 2 * cross section area taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="NetSurfaceArea_0bkjmepcXBxeA$GxmtGVIS" GlobalId="0bkjmepcXBxeA$GxmtGVIS" Name="NetSurfaceArea" Description="Net surface area of the object, normally generated as perimeter * length + 2 * cross section area taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses.

Total net surface area of the element after applying product-level geometric features such as openings and projections." />
				<IfcSimplePropertyTemplate id="NetSurfaceArea_0PdwcrZm12iONWHcDWlkPV" GlobalId="0PdwcrZm12iONWHcDWlkPV" Name="NetSurfaceArea" Description="Net surface area of the object, normally generated as perimeter * length + 2 * cross section area taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="NetSurfaceArea_1KDEyaMeH909yIpPWeAltl" GlobalId="1KDEyaMeH909yIpPWeAltl" Name="NetSurfaceArea" Description="Net surface area of the object, normally generated as perimeter * length + 2 * cross section area taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="NetSurfaceArea_2EIrVRpIv74w90Z74VC7Bq" GlobalId="2EIrVRpIv74w90Z74VC7Bq" Name="NetSurfaceArea" Description="Net surface area of the object, normally generated as perimeter * length + 2 * cross section area taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="NetSurfaceArea_2KH2BOElTBH9NU2YAau8oC" GlobalId="2KH2BOElTBH9NU2YAau8oC" Name="NetSurfaceArea" Description="Net surface area of the object, normally generated as perimeter * length + 2 * cross section area taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses.

Total net area of the inner surface of the chamber, subtracting any openings such as for pipes, ducts, or cables." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="NetVolume_0$PYHARu5Fux5AkfGewlyK" GlobalId="0$PYHARu5Fux5AkfGewlyK" Name="NetVolume" Description="Total net volume of the object, taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="NetVolume_05GG55xZz039SwUeIyPkET" GlobalId="05GG55xZz039SwUeIyPkET" Name="NetVolume" Description="Total net volume of the object, taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses.

Net volume enclosed by the space, excluding the volume of construction elements inside the space." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="NetVolume_0ERrc84nT7dgK$K5D$GP2M" GlobalId="0ERrc84nT7dgK$K5D$GP2M" Name="NetVolume" Description="Total net volume of the object, taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate GlobalId="0VFGaSH455JRzx81I_y2ka" Name="NetVolume" Description="Total net volume of the object, taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses.

Total net volume of the slab. Openings and recesses are taken into account by subtraction, projections by addition." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="NetVolume_0VFGaSH455JRzx81I_y2ka" GlobalId="0VFGaSH455JRzx81I_y2ka" Name="NetVolume" Description="Total net volume of the object, taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses.

Total net volume of the slab. Openings and recesses are taken into account by subtraction, projections by addition." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="NetVolume_0WOBpKa3L63h9k7gjdhvMQ" GlobalId="0WOBpKa3L63h9k7gjdhvMQ" Name="NetVolume" Description="Total net volume of the object, taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses.

Volume of the wall, after subtracting the openings and after considering the connection geometry." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="NetVolume_0zQ_lq_fzD3uXvq2fvIz0m" GlobalId="0zQ_lq_fzD3uXvq2fvIz0m" Name="NetVolume" Description="Total net volume of the object, taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="NetVolume_19Q0M8kyH4v9Gbdu9MtQKp" GlobalId="19Q0M8kyH4v9Gbdu9MtQKp" Name="NetVolume" Description="Total net volume of the object, taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="NetVolume_1EPVHEhWXF3OSxlo2Mfe9E" GlobalId="1EPVHEhWXF3OSxlo2Mfe9E" Name="NetVolume" Description="Total net volume of the object, taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses.

Sum of all net volumes of spaces enclosed by the building storey. It iexcludes the volumes of construction elements within the building storey. May be provided in addition to the quantities of the spaces assigned to the storey. In case of inconsistencies, the individual quantities of spaces take precedence." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="NetVolume_1nK2mIiXXDEwjVfHsSPCXF" GlobalId="1nK2mIiXXDEwjVfHsSPCXF" Name="NetVolume" Description="Total net volume of the object, taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="NetVolume_22Y7WG9CXC9uU51QkMI8w7" GlobalId="22Y7WG9CXC9uU51QkMI8w7" Name="NetVolume" Description="Total net volume of the object, taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses.

Total net volume of the stair flight. Openings and recesses are taken into account by subtraction, projections by addition." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="NetVolume_24v4IOU7b44wb4qQJZ8tyK" GlobalId="24v4IOU7b44wb4qQJZ8tyK" Name="NetVolume" Description="Total net volume of the object, taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses.

Sum of all net volumes of spaces enclosed by the building. It excludes the volumes of construction elements within the building. May be provided in addition to the quantities of the spaces assigned to the building. In case of inconsistencies, the individual quantities of spaces take precedence." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="NetVolume_2AmUyr_fj9LeY616EsLTf6" GlobalId="2AmUyr_fj9LeY616EsLTf6" Name="NetVolume" Description="Total net volume of the object, taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="NetVolume_3EY5xLcu9FDhkztmU94ZsX" GlobalId="3EY5xLcu9FDhkztmU94ZsX" Name="NetVolume" Description="Total net volume of the object, taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses.

Total net volume of the material, including material placed but excluding material wasted." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="NetVolume_3NHg39Thz2q98XexF17J6L" GlobalId="3NHg39Thz2q98XexF17J6L" Name="NetVolume" Description="Total net volume of the object, taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses.

Total net volume of the plate. Openings and recesses are taken into account by subtraction, projections by addition." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="NetVolume_3WY3yJjmD2h8sBobka$WyR" GlobalId="3WY3yJjmD2h8sBobka$WyR" Name="NetVolume" Description="Total net volume of the object, taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses.

Total net volume of the element before applying product-level geometric features such as openings and projections." />
				<IfcSimplePropertyTemplate id="NetVolume_3wYY9NR8r4IOia2k0qQWJm" GlobalId="3wYY9NR8r4IOia2k0qQWJm" Name="NetVolume" Description="Total net volume of the object, taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses.

Total net volume of the ramp flight. Openings and recesses are taken into account by subtraction, projections by addition." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="NetVolume_3YVB3yAvjBVh1KXE9$UEBr" GlobalId="3YVB3yAvjBVh1KXE9$UEBr" Name="NetVolume" Description="Total net volume of the object, taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses.

Total net volume of the chamber, subtracting any enclosed elements such as pipes, ducts, cables, or equipment." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="NetWallArea_1CjLoCIRL1gA$0S8yIZq2r" GlobalId="1CjLoCIRL1gA$0S8yIZq2r" Name="NetWallArea" Description="Sum of all wall (and other vertically bounding elements, like columns) areas bounded by the space. It excludes the area covered by elements inside the wall area (doors, windows, other openings, etc.)." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="NetWeight_0$CV4Oktb2yfPHSeCZVAcP" GlobalId="0$CV4Oktb2yfPHSeCZVAcP" Name="NetWeight" Description="Total net weight of the object without add-on parts, taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses.

Total net weight of the material, including material placed but excluding material wasted." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="NetWeight_0BZ0RgVvvB0Au49TCL2$Nc" GlobalId="0BZ0RgVvvB0Au49TCL2$Nc" Name="NetWeight" Description="Total net weight of the object without add-on parts, taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="NetWeight_0c7KxPg89A2QfJ4F5cvaOv" GlobalId="0c7KxPg89A2QfJ4F5cvaOv" Name="NetWeight" Description="Total net weight of the object without add-on parts, taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="NetWeight_0po45W9AL0j869JY4q3gta" GlobalId="0po45W9AL0j869JY4q3gta" Name="NetWeight" Description="Total net weight of the object without add-on parts, taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses.

Weight of the element, including contained fluid as designed." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="NetWeight_0Y4596MFP9rgJWM2TbuH_W" GlobalId="0Y4596MFP9rgJWM2TbuH_W" Name="NetWeight" Description="Total net weight of the object without add-on parts, taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses.

Weight of the element, including contained fluid as designed." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="NetWeight_17br2$zor1LeqOt68gddkK" GlobalId="17br2$zor1LeqOt68gddkK" Name="NetWeight" Description="Total net weight of the object without add-on parts, taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses.

Weight of the element, including contained fluid as designed." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="NetWeight_1IERUjvLP3pxK5DJNuud5g" GlobalId="1IERUjvLP3pxK5DJNuud5g" Name="NetWeight" Description="Total net weight of the object without add-on parts, taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses.

Weight of the element, including contained fluid as designed." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="NetWeight_2nny49wjT6zvfybFrRK81A" GlobalId="2nny49wjT6zvfybFrRK81A" Name="NetWeight" Description="Total net weight of the object without add-on parts, taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="NetWeight_2UMixgypn6_vTQPCfKjHEV" GlobalId="2UMixgypn6_vTQPCfKjHEV" Name="NetWeight" Description="Total net weight of the object without add-on parts, taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses.

Weight of the pipe segment, including contained fluid as designed." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="NetWeight_32ZfEUaFj1$8OmykwIZY3k" GlobalId="32ZfEUaFj1$8OmykwIZY3k" Name="NetWeight" Description="Total net weight of the object without add-on parts, taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="NetWeight_3G4CRKBErADwaGyOSxpRYZ" GlobalId="3G4CRKBErADwaGyOSxpRYZ" Name="NetWeight" Description="Total net weight of the beam without add-on parts, taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="NetWeight_3HPilonPX4eeqZc6gFTUVD" GlobalId="3HPilonPX4eeqZc6gFTUVD" Name="NetWeight" Description="Total net weight of the object without add-on parts, taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="NetWeight_3lOalFZebDWhdVL_UBJfxi" GlobalId="3lOalFZebDWhdVL_UBJfxi" Name="NetWeight" Description="Total net weight of the object without add-on parts, taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses.

Weight of the pipe fitting, including contained fluid as designed." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="NetWeight_3pzRYkes59nwqFKndMTa2o" GlobalId="3pzRYkes59nwqFKndMTa2o" Name="NetWeight" Description="Total net weight of the object without add-on parts, taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="NetWeight_3X6e4PloT6uwGFdMcoS7$x" GlobalId="3X6e4PloT6uwGFdMcoS7$x" Name="NetWeight" Description="Total net weight of the object without add-on parts, taking into account possible processing features (cut-out&apos;s, etc.) or openings and recesses." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="NumberOfCircuits_276gz8d_D6HvrpIUgEPq52" GlobalId="276gz8d_D6HvrpIUgEPq52" Name="NumberOfCircuits" Description="Number of circuits.

Number of circuits in the distribution board." TemplateType="q_count" />
				<IfcSimplePropertyTemplate id="NumberOfGangs_2BgsRMavrCrPKJ3CNzgxUQ" GlobalId="2BgsRMavrCrPKJ3CNzgxUQ" Name="NumberOfGangs" Description="Number of gangs in the object.

Number of gangs in the junction box." TemplateType="q_count" />
				<IfcSimplePropertyTemplate id="OperatingTime_0n6$0LVYnATeMVgUUUew6M" GlobalId="0n6$0LVYnATeMVgUUUew6M" Name="OperatingTime" Description="Productive time using the equipment including operating time and excluding idle time." TemplateType="q_time" />
				<IfcSimplePropertyTemplate id="OuterDiameter_0jKkyvvpnBAeZmRTuMJOyM" GlobalId="0jKkyvvpnBAeZmRTuMJOyM" Name="OuterDiameter" Description="The actual outer diameter of the object." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="OuterSurfaceArea_0Sxn$KyfzFGAdAfk1MI8U4" GlobalId="0Sxn$KyfzFGAdAfk1MI8U4" Name="OuterSurfaceArea" Description="Total area of the surfaces of the object (not taking into account the end cap areas), normally generated as perimeter * length in case of extrusions." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="OuterSurfaceArea_0zaqTRpZ13u8_Is$EV4Y5k" GlobalId="0zaqTRpZ13u8_Is$EV4Y5k" Name="OuterSurfaceArea" Description="Total area of the surfaces of the object (not taking into account the end cap areas), normally generated as perimeter * length in case of extrusions." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="OuterSurfaceArea_1979RC2snAGOJD0JG1bmlb" GlobalId="1979RC2snAGOJD0JG1bmlb" Name="OuterSurfaceArea" Description="Total area of the surfaces of the object (not taking into account the end cap areas), normally generated as perimeter * length in case of extrusions." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="OuterSurfaceArea_1MQJVdT3vDvO46QW5xymoP" GlobalId="1MQJVdT3vDvO46QW5xymoP" Name="OuterSurfaceArea" Description="Total area of the surfaces of the object (not taking into account the end cap areas), normally generated as perimeter * length in case of extrusions." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="OuterSurfaceArea_20rj_gmkPF7exM_ji7B7H0" GlobalId="20rj_gmkPF7exM_ji7B7H0" Name="OuterSurfaceArea" Description="Total area of the surfaces of the object (not taking into account the end cap areas), normally generated as perimeter * length in case of extrusions." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="OuterSurfaceArea_2bzs4tmt52fxOPREm6CF_J" GlobalId="2bzs4tmt52fxOPREm6CF_J" Name="OuterSurfaceArea" Description="Total area of the surfaces of the object (not taking into account the end cap areas), normally generated as perimeter * length in case of extrusions." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="OuterSurfaceArea_2L0loBn7rEgg3_kt6cKWME" GlobalId="2L0loBn7rEgg3_kt6cKWME" Name="OuterSurfaceArea" Description="Total area of the surfaces of the object (not taking into account the end cap areas), normally generated as perimeter * length in case of extrusions." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="OuterSurfaceArea_2mAoRzZ$z88A2WGwJTVhZx" GlobalId="2mAoRzZ$z88A2WGwJTVhZx" Name="OuterSurfaceArea" Description="The outer surface area of the arch element." />
				<IfcSimplePropertyTemplate id="OuterSurfaceArea_2MJAc_k71EXxlzJLPkV22f" GlobalId="2MJAc_k71EXxlzJLPkV22f" Name="OuterSurfaceArea" Description="Total area of the surfaces of the object (not taking into account the end cap areas), normally generated as perimeter * length in case of extrusions." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="OuterSurfaceArea_2PoZ2InkrCWeWRYmdawrLU" GlobalId="2PoZ2InkrCWeWRYmdawrLU" Name="OuterSurfaceArea" Description="Total area of the surfaces of the object (not taking into account the end cap areas), normally generated as perimeter * length in case of extrusions." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="OuterSurfaceArea_3Djq6vjjf6V9qaMMElokrY" GlobalId="3Djq6vjjf6V9qaMMElokrY" Name="OuterSurfaceArea" Description="Total area of the surfaces of the object (not taking into account the end cap areas), normally generated as perimeter * length in case of extrusions." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="OuterSurfaceArea_3Zqru$iTj468wzOOHOtodG" GlobalId="3Zqru$iTj468wzOOHOtodG" Name="OuterSurfaceArea" Description="Total area of the surfaces of the object (not taking into account the end cap areas), normally generated as perimeter * length in case of extrusions." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="OvertimeWork_3yAwOfIyL5_8$_rMJ_7kYP" GlobalId="3yAwOfIyL5_8$_rMJ_7kYP" Name="OvertimeWork" Description="Work that is performed after exceeding a particular limit such as hours per day and/or hours per week, after which company or municipal policy requires a different rate to apply. Note: Policies for when overtime takes effect are the responsibility of the user or application; they are not modelled in IFC." TemplateType="q_time" />
				<IfcSimplePropertyTemplate id="Perimeter_0dGrQtFfr8uQye1qU4pfXX" GlobalId="0dGrQtFfr8uQye1qU4pfXX" Name="Perimeter" Description="Perimeter of the object." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Perimeter_0vtU$HxUn5fR2RNi$2nSSt" GlobalId="0vtU$HxUn5fR2RNi$2nSSt" Name="Perimeter" Description="Perimeter of the object." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Perimeter_1eSAm0Kv1BzBMLz0DB0cYZ" GlobalId="1eSAm0Kv1BzBMLz0DB0cYZ" Name="Perimeter" Description="Perimeter of the object.

Perimeter measured along the outer boundaries of the plate. Only given, if the plate is prismatic (constant thickness)." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Perimeter_1sFKpDR$14zwRXxmfeKbrO" GlobalId="1sFKpDR$14zwRXxmfeKbrO" Name="Perimeter" Description="Perimeter of the object.

Perimeter measured along the outer boundaries of the slab. Only given, if the slab is prismatic (constant thickness)." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Perimeter_2XDJ5oQ3X8wuL8puElvYFm" GlobalId="2XDJ5oQ3X8wuL8puElvYFm" Name="Perimeter" Description="Perimeter of the object." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="PlanArea_19SFEqi01B3ALdNGRte$7C" GlobalId="19SFEqi01B3ALdNGRte$7C" Name="PlanArea" Description="Projected plan area of upper surface of model." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="PlanLength_1HyFyOJonBtx4V04qBUyEF" GlobalId="1HyFyOJonBtx4V04qBUyEF" Name="PlanLength" Description="Projected plan length of upper edge of slice." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="ProjectedArea_3fuF$itwL6PfQEQsct7uhL" GlobalId="3fuF$itwL6PfQEQsct7uhL" Name="ProjectedArea" Description="Total gross area of the outer surfaces of the roof, projected tp the ground. It is the sum of all projected roof slab gross areas. Roof openings, like sky windows and other openings and cut-outs are not taken into account." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="QuantityDryMass_0U8SRk8c13UxaUwwL94yqK" GlobalId="0U8SRk8c13UxaUwwL94yqK" Name="QuantityDryMass" Description="The quantity of dry grouting material." TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="QuantityGroutedMaterial_2MlJ6ltzX1lvzZf0dTe4TC" GlobalId="2MlJ6ltzX1lvzZf0dTe4TC" Name="QuantityGroutedMaterial" Description="The quantity of injected material." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="SignArea_32i2POqiz7sxewNKXzANau" GlobalId="32i2POqiz7sxewNKXzANau" Name="SignArea" Description="Sign Area" TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="StandardWork_0522jbkpH6RucITXMXI8fB" GlobalId="0522jbkpH6RucITXMXI8fB" Name="StandardWork" Description="Work that is performed at regular times, up to a particular limit after which overtime rates may apply." TemplateType="q_time" />
				<IfcSimplePropertyTemplate id="SurfaceGenusAfterFeatures_1OZSJQvSLA5BEIe1CJ$Ly8" GlobalId="1OZSJQvSLA5BEIe1CJ$Ly8" Name="SurfaceGenusAfterFeatures" Description="The Surface Genus of the evaluated representation items after applying product-level geometric features such as openings and projections.

Surface Genus is a topological measure that represents the number of &quot;holes&quot; or &quot;handles&quot; on a surface. For example, a sphere has genus 0, and a torus has genus 1.

Computed using the Euler characteristic:
$$
X=V−E+F
$$
With the numbers of vertices (V), edges (E) and faces (F)
$$
X=2−2g−b
$$
With surface genus (g) and the number of boundaries (b) the latter zero in case of an enclosed volume." />
				<IfcSimplePropertyTemplate id="SurfaceGenusBeforeFeatures_1atLAQl3158eB7fb8ixDWs" GlobalId="1atLAQl3158eB7fb8ixDWs" Name="SurfaceGenusBeforeFeatures" Description="The Surface Genus of the evaluated representation items before applying product-level geometric features such as openings and projections.

Surface Genus is a topological measure that represents the number of &quot;holes&quot; or &quot;handles&quot; on a surface. For example, a sphere has genus 0, and a torus has genus 1.

Computed using the Euler characteristic:
$$
X=V−E+F
$$
With the numbers of vertices (V), edges (E) and faces (F)
$$
X=2−2g−b
$$
With surface genus (g) and the number of boundaries (b) the latter zero in case of an enclosed volume." TemplateType="q_count" />
				<IfcSimplePropertyTemplate id="Thickness_13gGAsxojB8ezD5Qa2Ffa0" GlobalId="13gGAsxojB8ezD5Qa2Ffa0" Name="Thickness" Description="The thickness of the fill element." TemplateType="q_length" />
				<IfcSimplePropertyTemplate GlobalId="29hrivl4D9Xv3Ij$kS6FDr" Name="Thickness" Description="The geometric thickness of the object." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Thickness_29hrivl4D9Xv3Ij$kS6FDr" GlobalId="29hrivl4D9Xv3Ij$kS6FDr" Name="Thickness" Description="The geometric thickness of the object." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="TotalSurfaceArea_07HtwfSVT6rxawKdjsilwt" GlobalId="07HtwfSVT6rxawKdjsilwt" Name="TotalSurfaceArea" Description="Total surface area of the element.

Concerns the air terminal face plate." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="TotalSurfaceArea_09I0_N2T97QeOrJ9qSxfeT" GlobalId="09I0_N2T97QeOrJ9qSxfeT" Name="TotalSurfaceArea" Description="Total surface area of the element." TemplateType="q_area" />
				<IfcSimplePropertyTemplate id="TotalSurfaceArea_0tmUSCGyL09B1xy0j_abGA" GlobalId="0tmUSCGyL09B1xy0j_abGA" Name="TotalSurfaceArea" Description="Total surface area of the element." TemplateType="q_area" />
				<IfcSimplePropertyTemplate GlobalId="26rNXiavD40gy60NShbzTH" Name="UndisturbedVolume" Description="Undisturbed Volume." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="UndisturbedVolume_26rNXiavD40gy60NShbzTH" GlobalId="26rNXiavD40gy60NShbzTH" Name="UndisturbedVolume" Description="Undisturbed Volume." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="UsageTime_1_vxp4WGzDPu2rqx1zPOBW" GlobalId="1_vxp4WGzDPu2rqx1zPOBW" Name="UsageTime" Description="Total time using the equipment including operating time and idle time." TemplateType="q_time" />
				<IfcSimplePropertyTemplate id="Volume_0v4MMyo9v59fK0AkoEQN9i" GlobalId="0v4MMyo9v59fK0AkoEQN9i" Name="Volume" Description="Volume of the element.

Volume of the projection. It is the additional volume of the projection to the element (e.g. wall or slab)." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="Volume_1xhT9rkkvAp8YebJ0R7RY2" GlobalId="1xhT9rkkvAp8YebJ0R7RY2" Name="Volume" Description="Volume of the element.

Volume of the opening. It is the subtraction volume of the opening from the voided element (e.g. wall or slab). In case that the geometric volume of the opening is bigger then the subtraction volume, only the subtraction volume should be used." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="Volume_2CqQYjJ9j9hh6$pEk2Cym9" GlobalId="2CqQYjJ9j9hh6$pEk2Cym9" Name="Volume" Description="Volume of the element.

Total volume of the arch element." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="Volume_2SpRPw_wHB28DYepaP_sPV" GlobalId="2SpRPw_wHB28DYepaP_sPV" Name="Volume" Description="Volume of the element.

Volume represented, if lower surface of stratum known." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="Volume_3BTACZ5pz0q8DXhIjEk40F" GlobalId="3BTACZ5pz0q8DXhIjEk40F" Name="Volume" Description="The volume of the fill element." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate GlobalId="3Mf9e7UD5EZOIc4EQbT0xv" Name="Volume" Description="Volume of the element." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate GlobalId="3Mf9e7UD5EZOIc4EQbT0xv" Name="Volume" Description="Volume of the element." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate GlobalId="3Mf9e7UD5EZOIc4EQbT0xv" Name="Volume" Description="Volume of the element." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate GlobalId="3Mf9e7UD5EZOIc4EQbT0xv" Name="Volume" Description="Volume of the element." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate GlobalId="3Mf9e7UD5EZOIc4EQbT0xv" Name="Volume" Description="Volume of the element." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="Volume_3Mf9e7UD5EZOIc4EQbT0xv" GlobalId="3Mf9e7UD5EZOIc4EQbT0xv" Name="Volume" Description="Volume of the element." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="VolumeFlushedMaterial_0THcGlZYn6qfx3ZJm2hgbo" GlobalId="0THcGlZYn6qfx3ZJm2hgbo" Name="VolumeFlushedMaterial" Description="Material flushed from hole." />
				<IfcSimplePropertyTemplate id="VolumeInjectedMaterial_1h17Kx7y98vwjfGtgQxEW9" GlobalId="1h17Kx7y98vwjfGtgQxEW9" Name="VolumeInjectedMaterial" Description="Material injected into hole." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate id="VolumeOfTreatedGround_0ZXP9MrN515Q2_mkwqczn2" GlobalId="0ZXP9MrN515Q2_mkwqczn2" Name="VolumeOfTreatedGround" Description="Volume of treated ground." TemplateType="q_volume" />
				<IfcSimplePropertyTemplate GlobalId="2ueoe8QyrBduWuJHsi21zb" Name="Weight" Description="Total weight of object" TemplateType="q_weight" />
				<IfcSimplePropertyTemplate GlobalId="2ueoe8QyrBduWuJHsi21zb" Name="Weight" Description="Total weight of object" TemplateType="q_weight" />
				<IfcSimplePropertyTemplate GlobalId="2ueoe8QyrBduWuJHsi21zb" Name="Weight" Description="Total weight of object" TemplateType="q_weight" />
				<IfcSimplePropertyTemplate GlobalId="2ueoe8QyrBduWuJHsi21zb" Name="Weight" Description="Total weight of object" TemplateType="q_weight" />
				<IfcSimplePropertyTemplate GlobalId="2ueoe8QyrBduWuJHsi21zb" Name="Weight" Description="Total weight of object" TemplateType="q_weight" />
				<IfcSimplePropertyTemplate GlobalId="2ueoe8QyrBduWuJHsi21zb" Name="Weight" Description="Total weight of object" TemplateType="q_weight" />
				<IfcSimplePropertyTemplate GlobalId="2ueoe8QyrBduWuJHsi21zb" Name="Weight" Description="Total weight of object" TemplateType="q_weight" />
				<IfcSimplePropertyTemplate GlobalId="2ueoe8QyrBduWuJHsi21zb" Name="Weight" Description="Total weight of object" TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="Weight_2ueoe8QyrBduWuJHsi21zb" GlobalId="2ueoe8QyrBduWuJHsi21zb" Name="Weight" Description="Total weight of object" TemplateType="q_weight" />
				<IfcSimplePropertyTemplate id="Width_030qr7WMT5MBD4pdKmjYUh" GlobalId="030qr7WMT5MBD4pdKmjYUh" Name="Width" Description="The width of the object. Only given, if the object has constant thickness (prismatic)." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Width_0kW6jQBc58jhiMYyLtUSuv" GlobalId="0kW6jQBc58jhiMYyLtUSuv" Name="Width" Description="The width of the object. Only given, if the object has constant thickness (prismatic)." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Width_11fv2IEvP6SP_YXmR3EWfq" GlobalId="11fv2IEvP6SP_YXmR3EWfq" Name="Width" Description="The width of the object. Only given, if the object has constant thickness (prismatic)." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Width_18UcPG7iP4zfJktZU_maoy" GlobalId="18UcPG7iP4zfJktZU_maoy" Name="Width" Description="The width of the object. Only given, if the object has constant thickness (prismatic).

Total outer width of the window lining. It should only be provided, if it is a rectangular window." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Width_1QLByzVjv9cPk0IdwHiOd_" GlobalId="1QLByzVjv9cPk0IdwHiOd_" Name="Width" Description="The width of the object. Only given, if the object has constant thickness (prismatic).

Width of the opening, in case of wall openings it is the horizontal dimension in case of slab openings it is one horizontal dimension. Only provided, if the area is rectangular." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Width_1umP6DTx1ARBiyRaOC1gIU" GlobalId="1umP6DTx1ARBiyRaOC1gIU" Name="Width" Description="The width of the object. Only given, if the object has constant thickness (prismatic).

Only be provided, if it is constant along the curtain wall path." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Width_2_dPl2$Yf1ef9pXg253sc3" GlobalId="2_dPl2$Yf1ef9pXg253sc3" Name="Width" Description="The width of the object. Only given, if the object has constant thickness (prismatic).

Total outer width of the door lining. It should only be provided, if it is a rectangular door." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Width_2c$HEWc1b0ixiL$_rMctwP" GlobalId="2c$HEWc1b0ixiL$_rMctwP" Name="Width" Description="The width of the object. Only given, if the object has constant thickness (prismatic)." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Width_2ekc6Lw$vDfB57nG1Sm4wB" GlobalId="2ekc6Lw$vDfB57nG1Sm4wB" Name="Width" Description="The width of the object. Only given, if the object has constant thickness (prismatic).

Measured perpendicular to the wall path. It should only be provided, if it is constant along the wall path." TemplateType="q_length" />
				<IfcSimplePropertyTemplate GlobalId="2vkF8AsQL5fg4keqWbdE8G" Name="Width" Description="The width of the object. Only given, if the object has constant thickness (prismatic)." TemplateType="q_length" />
				<IfcSimplePropertyTemplate GlobalId="2vkF8AsQL5fg4keqWbdE8G" Name="Width" Description="The width of the object. Only given, if the object has constant thickness (prismatic)." TemplateType="q_length" />
				<IfcSimplePropertyTemplate GlobalId="2vkF8AsQL5fg4keqWbdE8G" Name="Width" Description="The width of the object. Only given, if the object has constant thickness (prismatic)." TemplateType="q_length" />
				<IfcSimplePropertyTemplate GlobalId="2vkF8AsQL5fg4keqWbdE8G" Name="Width" Description="The width of the object. Only given, if the object has constant thickness (prismatic)." TemplateType="q_length" />
				<IfcSimplePropertyTemplate GlobalId="2vkF8AsQL5fg4keqWbdE8G" Name="Width" Description="The width of the object. Only given, if the object has constant thickness (prismatic)." TemplateType="q_length" />
				<IfcSimplePropertyTemplate GlobalId="2vkF8AsQL5fg4keqWbdE8G" Name="Width" Description="The width of the object. Only given, if the object has constant thickness (prismatic)." TemplateType="q_length" />
				<IfcSimplePropertyTemplate GlobalId="2vkF8AsQL5fg4keqWbdE8G" Name="Width" Description="The width of the object. Only given, if the object has constant thickness (prismatic)." TemplateType="q_length" />
				<IfcSimplePropertyTemplate GlobalId="2vkF8AsQL5fg4keqWbdE8G" Name="Width" Description="The width of the object. Only given, if the object has constant thickness (prismatic)." TemplateType="q_length" />
				<IfcSimplePropertyTemplate GlobalId="2vkF8AsQL5fg4keqWbdE8G" Name="Width" Description="The width of the object. Only given, if the object has constant thickness (prismatic)." TemplateType="q_length" />
				<IfcSimplePropertyTemplate GlobalId="2vkF8AsQL5fg4keqWbdE8G" Name="Width" Description="The width of the object. Only given, if the object has constant thickness (prismatic)." TemplateType="q_length" />
				<IfcSimplePropertyTemplate GlobalId="2vkF8AsQL5fg4keqWbdE8G" Name="Width" Description="The width of the object. Only given, if the object has constant thickness (prismatic)." TemplateType="q_length" />
				<IfcSimplePropertyTemplate GlobalId="2vkF8AsQL5fg4keqWbdE8G" Name="Width" Description="The width of the object. Only given, if the object has constant thickness (prismatic)." TemplateType="q_length" />
				<IfcSimplePropertyTemplate GlobalId="2vkF8AsQL5fg4keqWbdE8G" Name="Width" Description="The width of the object. Only given, if the object has constant thickness (prismatic)." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Width_2vkF8AsQL5fg4keqWbdE8G" GlobalId="2vkF8AsQL5fg4keqWbdE8G" Name="Width" Description="The width of the object. Only given, if the object has constant thickness (prismatic)." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="Width_3iDhtJHuzC_gCAj5wdpWJh" GlobalId="3iDhtJHuzC_gCAj5wdpWJh" Name="Width" Description="The width of the object. Only given, if the object has constant thickness (prismatic).

For strip footings it is measured perpendicular to the footing path (or longitudial axis). For other footings it is one of the horizontal dimensions. It should only be provided, if it is constant." TemplateType="q_length" />
				<IfcSimplePropertyTemplate id="WidthTreatedArea_0ztm4zUhDBwBTxoEEeJumR" GlobalId="0ztm4zUhDBwBTxoEEeJumR" Name="WidthTreatedArea" Description="Width of treated area." />
			</RelatedDefinitions>
		</IfcRelDeclares>
		<IfcRelDeclares GlobalId="1CpAEUB6v1Fhb57tduNMhL" Name="QuantitySets">
			<RelatedDefinitions>
				<IfcPropertySetTemplate GlobalId="1hQlisg0zEYxyhYL8vsAz3" Name="Qto_ActuatorBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of actuator." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcActuator">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_1smEkXY$r3gP1FYpbiEjLd" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1rUOXyK7zFNfBaifdAM3yy" Name="Qto_AirTerminalBaseQuantities" Description="Base quantities that are common to the definition of all types of air terminals." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcAirTerminal">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_2O4Iq5oVPAKfwTsy3SBhvP" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Perimeter_0dGrQtFfr8uQye1qU4pfXX" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TotalSurfaceArea_07HtwfSVT6rxawKdjsilwt" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0p50lClkHF$OLKmchSamAx" Name="Qto_AirTerminalBoxTypeBaseQuantities" Description="Base quantities that are common to the definition of all types of air terminal boxes." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcAirTerminalBox">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_2KoN62q3fBdOzd1dky$NLy" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0VOkgKMKX1dx$MPmWIA8sA" Name="Qto_AirToAirHeatRecoveryBaseQuantities" Description="Base quantities that are common to the definition of all types of air-to-air heat recovery elements." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcAirToAirHeatRecovery">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_0Ieqrchcb2fe7R9p1VfZHd" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0iG0enKiv1MusSHQ63VJc2" Name="Qto_AlarmBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of alarm." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcAlarm">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_1InDYDQ0bF4887_MZria4x" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1jBiZHbBT6a9yQmZMKDX7A" Name="Qto_ArchElementBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of arch elements." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcArchElement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Length_2U468iDh12lfpRdFjlDGpa" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Volume_2CqQYjJ9j9hh6$pEk2Cym9" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CrossSectionArea_1BWpnfBwb1k82WvJ6vFVRf" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OuterSurfaceArea_2mAoRzZ$z88A2WGwJTVhZx" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="InnerSurfaceArea_1bO4eo9tXEOBFCON4r8KnZ" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2S5$9w7kbFUQZD_9dp3trc" Name="Qto_ArealStratumBaseQuantities" Description="Quantity measures associated to areal stratum such as in a geotechnical slice. Uncertainty is documented in _Pset_Uncertainty_." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcGeotechnicalStratum">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Area_30mgAbQ1T07OVkS7olRIhF" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Length_2$jJcrH4rEGfeVtDgy1kcg" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PlanLength_1HyFyOJonBtx4V04qBUyEF" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="070voD4dn7UBLpwIwudHlZ" Name="Qto_AudioVisualApplianceBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of audio visual appliance." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcAudioVisualAppliance">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_0KoyVFQXjEcRNAUBqltG6$" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1WqlIvvu96zedruLGqvnZ1" Name="Qto_BeamBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of beams." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcBeam">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Length_3HAJVhcK15aw_kd5ahVYMn" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CrossSectionArea_0PPnhNUJTDPeNa7OZnh4ij" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OuterSurfaceArea_1979RC2snAGOJD0JG1bmlb" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossSurfaceArea_184cNPB754Ig7C0fjvOfSD" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetSurfaceArea_0AxNPioRr2f8eBaIvLf9Ep" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossVolume_1yO7vl54P1TQOXcUVdO$xX" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetVolume_19Q0M8kyH4v9Gbdu9MtQKp" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_2LSqYKQbr9uBpg1Y1sZLZ4" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetWeight_3G4CRKBErADwaGyOSxpRYZ" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2b3yk6OLD9$gvh6Mu4GFy1" Name="Qto_BodyGeometryValidation" Description="Quantities supplied for validating the correct interpretation of the body shape representation at import. In case of multiple representation items, the quantities are summed for each of the items (irrespective of any overlap). Choosing a suitable tolerance value for comparing the supplied numbers to the numbers calculated from the reconstructed geometry is at the discretion of the importing application." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcProduct">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossSurfaceArea_37jdwMgmf35wihgfyazkKB" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetSurfaceArea_0bkjmepcXBxeA$GxmtGVIS" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossVolume_2vCxWbK8v4KO8xK1S_xlsP" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetVolume_3WY3yJjmD2h8sBobka$WyR" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SurfaceGenusBeforeFeatures_1atLAQl3158eB7fb8ixDWs" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SurfaceGenusAfterFeatures_1OZSJQvSLA5BEIe1CJ$Ly8" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="01rtunlen7SwNeUJYV0yMI" Name="Qto_BoilerBaseQuantities" Description="Base quantities that are common to the definition of all types of boilers." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcBoiler">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_0xfN4KKdn3yvuyD3Xzzt16" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetWeight_0Y4596MFP9rgJWM2TbuH_W" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TotalSurfaceArea_0tmUSCGyL09B1xy0j_abGA" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2agcKcpyPEEBdh0lm9p6kJ" Name="Qto_BuildingBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of building." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcBuilding">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Height_0l46kxLer8ZvIAfet6uUEt" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="EavesHeight_3fzA40seP3xRirGVCr9Rg5" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FootPrintArea_340fmI0CnBFRkREE87BmUJ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossFloorArea_2$BKrxu3X3_O8KrqJC$E6B" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetFloorArea_1JBcBU2tH1v8Bm7_Eqqb3T" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossVolume_2051xg09X1z8mAolsFi5do" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetVolume_24v4IOU7b44wb4qQJZ8tyK" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3zYQzbKe92YuH7wKFHp2bq" Name="Qto_BuildingElementProxyQuantities" Description="Quantity set for Building Element Proxies." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcBuildingElementProxy">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetSurfaceArea_0PdwcrZm12iONWHcDWlkPV" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetVolume_2AmUyr_fj9LeY616EsLTf6" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="18nKWzW1HATRtU6jiaMHcZ" Name="Qto_BuildingStoreyBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of building storey." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcBuildingStorey">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossHeight_2c3FJy8d519BbNZUzYQ6j8" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetHeight_1$6dDMwur71g6f0RlcwV8j" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossPerimeter_3ju92XNCL9te0aUSyUzuHf" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossFloorArea_3WwOtqsUDESuFkdurgxsdW" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetFloorArea_3xbBzAevX6Jw2IeZhyIsFb" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossVolume_2yvxaQH3v4S8nrMT36FEuh" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetVolume_1EPVHEhWXF3OSxlo2Mfe9E" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3FcHcEK8n6ZxgNDBpbvW4M" Name="Qto_BurnerBaseQuantities" Description="Base quantities that are common to the definition of all types of burners." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcBurner">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_2J02SRun51HAwYTeufRxcY" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0fqGvTlSTDxPZcWlJ3pkV8" Name="Qto_CableCarrierFittingBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of cable carrier fitting." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcCableCarrierFitting">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_1Dk$VgoEfASfOYW7$rDZlP" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2ydTl6DTfEaQ6azgvHLiBu" Name="Qto_CableCarrierSegmentBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of cable carrier segment." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcCableCarrierSegment">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_0w_kKl$I9Bo84EzPE$16E9" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Length_2z1P39Ymn4hPye8Niet8tP" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CrossSectionArea_0uyuKqXOz1N8mN8NTuQ33t" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OuterSurfaceArea_3Djq6vjjf6V9qaMMElokrY" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1Sx_GzB5r5FvwKjehrfxBs" Name="Qto_CableFittingBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of flow cable fitting." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcCableFitting">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_2T$jnrHN90jR1dfV6miZ_4" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2LBZwvHXPCK9oTZaEkCXGI" Name="Qto_CableSegmentBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of cable segment." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcCableSegment">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_1oiTCHhz51wBmEpe_mOLJW" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Length_0GQgOEFyz7XxNg7uky7YDi" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CrossSectionArea_0vA4m$lVzAix3yMfG26YjY" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OuterSurfaceArea_3Zqru$iTj468wzOOHOtodG" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0LObKgIxr3M9NBfDFwyo81" Name="Qto_ChillerBaseQuantities" Description="Base quantities that are common to the definition of all types of chillers." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcChiller">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_14fujPcAX9KQOvAie9AvUO" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2hQlC5OAP3te3pobw9Os_4" Name="Qto_ChimneyBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of chimneys." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcChimney">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Length_0wFNjuTo99Yhev5$Z803q5" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0OlJUKLcT0YQ0P1qQAYPLc" Name="Qto_CoilBaseQuantities" Description="Base quantities that are common to the definition of all types of coils." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcCoil">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_1SLwhC5or6kR8QJW$2Ppdn" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0wj8YogyLApO2264_bkSBD" Name="Qto_ColumnBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of columns." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcColumn">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Length_3z_1RK79zEYQlNxgE2SP3k" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CrossSectionArea_3azvi2X2n83u27ua2yTjY7" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OuterSurfaceArea_2bzs4tmt52fxOPREm6CF_J" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossSurfaceArea_20Esv0DRX5ygqyDjBoU9UK" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetSurfaceArea_1KDEyaMeH909yIpPWeAltl" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossVolume_3OYqYJKmPDBO6hW164LcIC" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetVolume_0ERrc84nT7dgK$K5D$GP2M" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_0NZqCLyJL038dOoXtrPjvo" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetWeight_2nny49wjT6zvfybFrRK81A" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2CXsY9A6D3R9QD9xndyc3m" Name="Qto_CommunicationsApplianceBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of communications appliance." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcCommunicationsAppliance">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_26DiA$pC1DXQ7y1wOVBdVa" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1Pb8AaH45FOugiLQx1u45k" Name="Qto_CompressorBaseQuantities" Description="Base quantities that are common to the definition of all types of compressors." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcCompressor">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_1lMSRiVnL6uv6REGn4e0Im" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3imN6wBoT21BeRAl3lq4OH" Name="Qto_CondenserBaseQuantities" Description="Base quantities that are common to the definition of all types of condensers." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcCondenser">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_2wCGB$0tr1RgwfPgSrkn7b" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="30zvdvQo99qR9afTpcLTh1" Name="Qto_ConduitSegmentBaseQuantities" Description="Quantity set of Conduit Segment Base." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcCableCarrierSegment/CONDUITSEGMENT">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="InnerDiameter_2rMNdLyMj5mAE00RNkEMm9" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OuterDiameter_0jKkyvvpnBAeZmRTuMJOyM" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="04rpJ_Z09EPxleo8w3GXRF" Name="Qto_ConstructionEquipmentResourceBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of construction equipment resources." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcConstructionEquipmentResource">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="UsageTime_1_vxp4WGzDPu2rqx1zPOBW" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OperatingTime_0n6$0LVYnATeMVgUUUew6M" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3EQia4nD1DFArF2uEYAQYR" Name="Qto_ConstructionMaterialResourceBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of construction material resources." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcConstructionMaterialResource">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossVolume_30poMMOJL2rB0$xyTEd8wz" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetVolume_3EY5xLcu9FDhkztmU94ZsX" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_1JO2FNSBD94wMmbjBm7Ry1" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetWeight_0$CV4Oktb2yfPHSeCZVAcP" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="07k$A1OzL9uRJ3nTCr3cb2" Name="Qto_ControllerBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of controller." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcController">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_38TydLycj6F8aNN0BZ7Mjn" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3Agbfu_L91zBpikqO7W7y6" Name="Qto_CooledBeamBaseQuantities" Description="Base quantities that are common to the definition of all types of cooled beams." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcCooledBeam">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_3AKYGF6Av9qfecEq71L9Bs" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0IY1eQ69v2W82OFHdAkRk1" Name="Qto_CoolingTowerBaseQuantities" Description="Base quantities that are common to the definition of all types of cooling towers." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcCoolingTower">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_39PZMMXFXETf4ONj$4IUnm" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2p9fsZzbXAOfoqSj3HSnG$" Name="Qto_CourseBaseQuantities" Description="" TemplateType="qto_occurrencedriven" ApplicableEntity="IfcCourse">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Length_12VlqG8sb7DQA2dQlUV7OR" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Width_2vkF8AsQL5fg4keqWbdE8G" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Thickness_29hrivl4D9Xv3Ij$kS6FDr" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Volume_3Mf9e7UD5EZOIc4EQbT0xv" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossVolume_14RqdfQXT4qQ82_ZE93nfB" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Weight_2ueoe8QyrBduWuJHsi21zb" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3chsxKUDb01fGyiSzCJuqu" Name="Qto_CoveringBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of coverings applied to spaces." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcCovering">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Width_11fv2IEvP6SP_YXmR3EWfq" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossArea_1v7Z5Yk4T0fu61b7WfpuHO" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetArea_184ko6bvr3dxtoDs6$yNLT" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2mL_7pbyzDRQzec4nXsUe8" Name="Qto_CurtainWallQuantities" Description="Base quantities that are common to the definition of all occurrences of curtain walls." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcCurtainWall">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Length_0r0CjuAFbF5ht38RfIA5VC" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Height_1KsfmdV9XDWPeiUZciB6O0" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Width_1umP6DTx1ARBiyRaOC1gIU" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossSideArea_1zC$OvtlX2yx3GZJuKLxl$" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetSideArea_0FyqBJJ3P1O8EEKU9cgC1X" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3KFL1YA_f6XRFLjLTzKzvk" Name="Qto_DamperBaseQuantities" Description="Base quantities that are common to the definition of all types of dampers." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcDamper">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_1tAY9vaCvFCOduhWxgb6eA" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0M0WSoFor1iO2KrjUU3j2L" Name="Qto_DistributionBoardBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of electric distribution board." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcElectricDistributionBoard">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_0T$xcLLdz2ZArODjG93KwI" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfCircuits_276gz8d_D6HvrpIUgEPq52" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1PbuJBYcPDDBcEG8o4osEB" Name="Qto_DistributionChamberElementBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of distribution chamber elements." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcDistributionChamberElement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossSurfaceArea_120Q7UCrL28efVUqFX0kQ2" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetSurfaceArea_2KH2BOElTBH9NU2YAau8oC" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossVolume_23Oh8d2BTDXxVHWoDjmHE8" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetVolume_3YVB3yAvjBVh1KXE9$UEBr" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Depth_3RJBqFyPr5BuHqJx2YiXLV" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1AwqSBBljB1RN5AiAiBqI8" Name="Qto_DoorBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of doors." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcDoor">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Width_2_dPl2$Yf1ef9pXg253sc3" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Height_3x$bGOprDCQgg7xK4PC4OC" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Perimeter_2XDJ5oQ3X8wuL8puElvYFm" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Area_1cEbPpN7L4E8Pc7CR8aDZC" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3oxMktgxb0qulsbpIYSt4O" Name="Qto_DuctFittingBaseQuantities" Description="Base quantities that are common to the definition of all types and occurrences of duct fittings." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcDuctFitting">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Length_0LFcPBJ55FxAJ9btosgfER" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossCrossSectionArea_3Y4GBXe0vDmAgrj3olDdVZ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetCrossSectionArea_26xd6BAzbCXwSo5dPGpKlq" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OuterSurfaceArea_2MJAc_k71EXxlzJLPkV22f" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_3la6Kpg0XCKuqOgL4JE7p$" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3$szzzmXHEHP5n9K93yL2J" Name="Qto_DuctSegmentBaseQuantities" Description="Base quantities that are common to the definition of all types and occurrences of duct segments." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcDuctSegment">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Length_0Pplv_8rXDmfDaqsRu1pzv" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossCrossSectionArea_3V84HqO9P4GQ8WTeEY_9bp" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetCrossSectionArea_0oC5ZHnEP5ahhXtNd1QWtv" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OuterSurfaceArea_0Sxn$KyfzFGAdAfk1MI8U4" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_0WIMBK5rbFRwB247cORYJz" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3NOV0Ugdf05xjLnVzCZP0j" Name="Qto_DuctSilencerBaseQuantities" Description="Base quantities that are common to the definition of all types of duct silencers." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcDuctSilencer">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_0rA2jWN0n0yw1RyiILIi4c" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1sPBaofsP5KhTcd2mOfWsN" Name="Qto_EarthworksCutBaseQuantities" Description="Quantity set for Earthworks Cut Base." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcEarthworksCut">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Length_12VlqG8sb7DQA2dQlUV7OR" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Width_2vkF8AsQL5fg4keqWbdE8G" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Depth_1EfY1EUxjCYfMfDim4N8cC" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UndisturbedVolume_26rNXiavD40gy60NShbzTH" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LooseVolume_1f8iHGSB91FBK9qA7FuE68" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Weight_2ueoe8QyrBduWuJHsi21zb" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3rwKfiQiH5gOMG_$_CQwCH" Name="Qto_EarthworksFillBaseQuantities" Description="Quantity set for Earthworks Fill Base." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcEarthworksFill">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Length_12VlqG8sb7DQA2dQlUV7OR" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Width_2vkF8AsQL5fg4keqWbdE8G" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Depth_1EfY1EUxjCYfMfDim4N8cC" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CompactedVolume_1clL3F_GzEROzZL0CFLOfa" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LooseVolume_1f8iHGSB91FBK9qA7FuE68" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="15r$LAMGvBZAESSqu1wbW$" Name="Qto_ElectricApplianceBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of electric appliance." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcElectricAppliance">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_1YT_g1nn98PP66gwW3cQCy" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0cRr4uAUT5iRUtJkPo2Fph" Name="Qto_ElectricFlowStorageDeviceBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of electric flow storage device." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcElectricFlowStorageDevice">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_3Mtbk432rEdwcRhIyj1HD9" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3WKSMIs4b1QBRSZhY4D$cf" Name="Qto_ElectricGeneratorBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of electric generator." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcElectricGenerator">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_00ihrh0tn1tBXJu$zIJzjG" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3uSlMn59921O9iTHPrmSY1" Name="Qto_ElectricMotorBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of electric motor." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcElectricMotor">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_3_YG1FBCHCqRo0R5SCOcRW" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2urlrDpJrF4fBsdeqGr5vJ" Name="Qto_ElectricTimeControlBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of electric time control." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcElectricTimeControl">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_0TyiBj$lL5W8Ee7G3FWcIm" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1hHSvz5dH9MPWScma3lpAo" Name="Qto_EvaporativeCoolerBaseQuantities" Description="Base quantities that are common to the definition of all types of evaporative coolers." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcEvaporativeCooler">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_2BHKqYW6f5qfS1C8h8pBXw" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2pyLu0aJXAVv0$j9GMahnC" Name="Qto_EvaporatorBaseQuantities" Description="Base quantities that are common to the definition of all types of evaporators." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcEvaporator">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_3Izxj$rfDDDeX2r8M2eeI3" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1sPBaofsP5KhTcd2mOfWsN" Name="Qto_ExcavationBaseQuantities" Description="Base quantities for excavations." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcExcavation">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Length_12VlqG8sb7DQA2dQlUV7OR" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Width_2vkF8AsQL5fg4keqWbdE8G" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Depth_1EfY1EUxjCYfMfDim4N8cC" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="UndisturbedVolume_26rNXiavD40gy60NShbzTH" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="LooseVolume_1f8iHGSB91FBK9qA7FuE68" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Weight_2ueoe8QyrBduWuJHsi21zb" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1zrpEJjST5yuSoETOwFAuL" Name="Qto_FacilityPartBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of _IfcFacilityPart_." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcFacilityPart">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Length_12VlqG8sb7DQA2dQlUV7OR" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Width_2vkF8AsQL5fg4keqWbdE8G" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Height_3jq0d8r0zBYvccpej6okcm" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Area_1CnNsFYBT6$AemE3IaDxL7" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Volume_3Mf9e7UD5EZOIc4EQbT0xv" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3FHIXjhWn419r3W1Nx5ybt" Name="Qto_FanBaseQuantities" Description="Base quantities that are common to the definition of all types of fans." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcFan">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_3cW_u6Vwz3hBkTHlmfnLH4" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="34$dxTrBzD3B$JpEjPG$6h" Name="Qto_FillElementBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of fill elements." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcFillElement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Thickness_13gGAsxojB8ezD5Qa2Ffa0" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Volume_3BTACZ5pz0q8DXhIjEk40F" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0Cle0SIDH3tgns50MFUIbA" Name="Qto_FilterBaseQuantities" Description="Base quantities that are common to the definition of all types of filters." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcFilter">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_0mGDb85BT0dxQniWrPEA3L" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0E2NxR3DPCcg__l_owuZYl" Name="Qto_FireSuppressionTerminalBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of fire suppression terminal." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcFireSuppressionTerminal">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_1pB5sgAv56UxQS0smeQqw5" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3esZIXApz4fgRBJO3wa35f" Name="Qto_FlowInstrumentBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of flow instrument." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcFlowInstrument">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_3Q$qPXmMn6NRL$$A2RD36z" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2e2sfrsyL2pQBvjW9C60mu" Name="Qto_FlowMeterBaseQuantities" Description="Base quantities that are common to the definition of all types of flow meters." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcFlowMeter">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_3lrUWsH417HvsqNKqd7kb7" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0S8Fx9Ucb6dQcR8Wu0A85Z" Name="Qto_FootingBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of footings." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcFooting">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Length_21NkL6Eqj1Y9ibmbKT0sJZ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Width_3iDhtJHuzC_gCAj5wdpWJh" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Height_2fZo2S2rzBOhweGqI3yt36" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CrossSectionArea_2$G4u$rCL82vYqsTtwoWn4" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OuterSurfaceArea_1MQJVdT3vDvO46QW5xymoP" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossSurfaceArea_0hLLA7UuvCVPodj1bFWFtl" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossVolume_3Wcqtil2n9iwS_wUu2QT78" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetVolume_0$PYHARu5Fux5AkfGewlyK" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_3_haAJs21108lznLPBkIMM" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetWeight_3X6e4PloT6uwGFdMcoS7$x" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1$S1A04gz3mQzn6FT22hNz" Name="Qto_HeatExchangerBaseQuantities" Description="Base quantities that are common to the definition of all types of heat exchangers." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcHeatExchanger">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_3jsd$iRZPAewmF$8het2R_" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0xanh$x9j7CvhHS3sljUjA" Name="Qto_HumidifierBaseQuantities" Description="Base quantities that are common to the definition of all types of humidifiers." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcHumidifier">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_2ReQoK7HLCnBnSyvF4LETx" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1EswxrRsL1CQMu5t82adUe" Name="Qto_ImpactProtectionDeviceBaseQuantities" Description="Quantity set Impact Protection Device Base." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcImpactProtectionDevice">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Weight_2ueoe8QyrBduWuJHsi21zb" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0R1XY4BEX3E913VtVolSjo" Name="Qto_ImprovedGroundBaseQuantities" Description="Quantity measures associated to improved ground." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcImprovedGround">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="LengthTreatedArea_22EC_Kwwz6oPOJDIRf0AmV" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="WidthTreatedArea_0ztm4zUhDBwBTxoEEeJumR" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VolumeOfTreatedGround_0ZXP9MrN515Q2_mkwqczn2" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1D4ZXfhsjFuudOPR46vv_A" Name="Qto_ImprovedGroundInjectionGroutedQuantities" Description="Quantities associated with injection grouting." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcImprovedGround/INJECTIONGROUTED">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="QuantityDryMass_0U8SRk8c13UxaUwwL94yqK" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="QuantityGroutedMaterial_2MlJ6ltzX1lvzZf0dTe4TC" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1j7XVXaNvDWBvm6DiZVkgV" Name="Qto_ImprovedGroundJetGroutedQuantities" Description="Quantities associated with jet grouting." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcImprovedGround/JETGROUTED">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="VolumeInjectedMaterial_1h17Kx7y98vwjfGtgQxEW9" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="VolumeFlushedMaterial_0THcGlZYn6qfx3ZJm2hgbo" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="12O8y5wib0NRG1JAXWL7ra" Name="Qto_InterceptorBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of interceptor." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcInterceptor">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_28jiUHD35D2AF5FBGtoEN7" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0dPw5tVT17uRc_J_5M3pCO" Name="Qto_JunctionBoxBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of junction box." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcJunctionBox">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_07h3fAPAn46BMgkN7z3M_c" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NumberOfGangs_2BgsRMavrCrPKJ3CNzgxUQ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Length_12VlqG8sb7DQA2dQlUV7OR" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Width_2vkF8AsQL5fg4keqWbdE8G" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Height_3jq0d8r0zBYvccpej6okcm" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0sfS47qTDC_uvImFylhbKz" Name="Qto_KerbBaseQuantities" Description="Quantity set for Kerb Base." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcKerb">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Length_12VlqG8sb7DQA2dQlUV7OR" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Width_2vkF8AsQL5fg4keqWbdE8G" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Height_3jq0d8r0zBYvccpej6okcm" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Depth_1EfY1EUxjCYfMfDim4N8cC" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Volume_3Mf9e7UD5EZOIc4EQbT0xv" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Weight_2ueoe8QyrBduWuJHsi21zb" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2Y01H7$fX3fRwDe96uYUsW" Name="Qto_LaborResourceBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of labour resources." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcLaborResource">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="StandardWork_0522jbkpH6RucITXMXI8fB" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OvertimeWork_3yAwOfIyL5_8$_rMJ_7kYP" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0ZhFR_pJTCVAmRW49VTo0Z" Name="Qto_LampBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of lamp." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcLamp">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_25G6PPARz5aelYP_pgRJGa" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2e$DkmMHL7L8FsT5UB9$D_" Name="Qto_LightFixtureBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of light fixture." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcLightFixture">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_1SeGGNb75AXfTrOHr7Myp9" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0uOCy_pGv4HuAxLx$ilI0j" Name="Qto_LinearStratumBaseQuantities" Description="Quantity measures associated to a linear stratum such as in a borehole. Uncertainty is documented in _Pset_Uncertainty_." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcGeotechnicalStratum">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Diameter_0vS54g5YD0D8XXzjqMTI8V" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Length_2$G8M_eiDEgwJIrvinbXuH" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0xBy0_$YzCkfAeO0wiKwTF" Name="Qto_MarineFacilityBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of _IfcMarineFacility_." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcMarineFacility">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Length_12VlqG8sb7DQA2dQlUV7OR" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Width_2vkF8AsQL5fg4keqWbdE8G" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Height_3jq0d8r0zBYvccpej6okcm" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Area_1CnNsFYBT6$AemE3IaDxL7" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Volume_3Mf9e7UD5EZOIc4EQbT0xv" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="07wXL8A2r2yQeCTXi_Vopj" Name="Qto_MemberBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of members." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcMember">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Length_23VJ9cbmr7Z8nLCL2Ztv7T" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CrossSectionArea_1CJ9V2eIP2VOxFOXznhRyr" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OuterSurfaceArea_2L0loBn7rEgg3_kt6cKWME" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossSurfaceArea_2p6SNTq5v2DwZaZ4YwQmqm" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetSurfaceArea_2EIrVRpIv74w90Z74VC7Bq" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossVolume_2lARuJES14dQ4cw2yiAyV3" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetVolume_0zQ_lq_fzD3uXvq2fvIz0m" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_1auc77qC52AhlGJuEOoQbg" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetWeight_0BZ0RgVvvB0Au49TCL2$Nc" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1o_Kz1MEv6IOx4yAbdGBGC" Name="Qto_MotorConnectionBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of motor connection." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcMotorConnection">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_2A4lBn5Xn2EQAoHY6UT1X0" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="298sOI5jj159r1s4w0pAhc" Name="Qto_OpeningElementBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of opening elements." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcOpeningElement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Width_1QLByzVjv9cPk0IdwHiOd_" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Height_0NXCOa3OXFE9$sWnHvmoai" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Depth_1AXq7x3FH3sAkrb38n1WIf" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Area_1Z0opsKy51wvKZDpfJdCc_" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Volume_1xhT9rkkvAp8YebJ0R7RY2" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3bHVH_iKvB7glUHyNTHM8n" Name="Qto_OutletBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of outlet." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcOutlet">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_0W1Al0vZn0Vh8zIAJto8ij" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1wcLUssjzDxBr3gFI_oXNJ" Name="Qto_PavementBaseQuantities" Description="Quantity set for Pavement." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcPavement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Length_12VlqG8sb7DQA2dQlUV7OR" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Width_2vkF8AsQL5fg4keqWbdE8G" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Depth_1EfY1EUxjCYfMfDim4N8cC" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossArea_2xt4x2$lzD8wZCrac3MEZ0" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetArea_29izq2o8PDM9ZgFTCAF4ra" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossVolume_14RqdfQXT4qQ82_ZE93nfB" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetVolume_0VFGaSH455JRzx81I_y2ka" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="30U52MSOf5dOhejs29lcq6" Name="Qto_PictorialSignQuantities" Description="Quantity set for Pictorial Signs." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcSign/PICTORAL">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Area_1CnNsFYBT6$AemE3IaDxL7" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="SignArea_32i2POqiz7sxewNKXzANau" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2G1lJVyMT9kvpPesdMi1jZ" Name="Qto_PileBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of piles." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcPile">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Length_2XuGBfa51FBAheQBk7g7Tw" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="CrossSectionArea_0emE4jyCbE2fJiXgNRE_O9" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OuterSurfaceArea_2PoZ2InkrCWeWRYmdawrLU" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossSurfaceArea_11MDrBp2P3uAraI7SKsVMq" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossVolume_38iKg02F54r909_c7iOrrL" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetVolume_1nK2mIiXXDEwjVfHsSPCXF" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_0pK5JtwqjBqOGb7AJQkCo1" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetWeight_0c7KxPg89A2QfJ4F5cvaOv" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0fTy0Vau90jgn2NeB8UR1U" Name="Qto_PipeFittingBaseQuantities" Description="Base quantities that are common to the definition of all types and occurrences of pipe fittings." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcPipeFitting">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Length_1dACFzC1n5mupC7A4jIXpl" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossCrossSectionArea_0CTO01q$f9S92svrhALSXK" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetCrossSectionArea_0kVAuHyLz45AM0hLPZMgMm" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OuterSurfaceArea_20rj_gmkPF7exM_ji7B7H0" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_2Ru4nYFdvDbhu6lV6WlOcT" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetWeight_3lOalFZebDWhdVL_UBJfxi" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1gRj3JDc19RxxVo8Ftcpyq" Name="Qto_PipeSegmentBaseQuantities" Description="Base quantities that are common to the definition of all types and occurrences of pipe segments." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcPipeSegment">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Length_2fejRsTX5CrOwvJ8uiZiDk" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossCrossSectionArea_1$PKD3pIz8huUfNLJLdqeC" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetCrossSectionArea_0KrsSEz1T1XfJ0QzSOxLHh" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="OuterSurfaceArea_0zaqTRpZ13u8_Is$EV4Y5k" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_2XO1E_VubFKvIvNoae447X" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetWeight_2UMixgypn6_vTQPCfKjHEV" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FootPrintArea_2$0cTYdvf6QO8z1nvVIBpB" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3mesejfMT2DgXjJl$hxqFX" Name="Qto_PlateBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of plates." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcPlate">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Width_0kW6jQBc58jhiMYyLtUSuv" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Perimeter_1eSAm0Kv1BzBMLz0DB0cYZ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossArea_2ZKkm9Tab4_QDxvaNB3E7K" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetArea_17ubdukNb0W9aXEckuuiud" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossVolume_0eJM_AYGPDGBeQZ_tEdSxG" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetVolume_3NHg39Thz2q98XexF17J6L" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_07xyOpYN1ENPlFP$7E14qH" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetWeight_3HPilonPX4eeqZc6gFTUVD" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3tWI3hSgvD6O3EMXqL4Lbd" Name="Qto_ProjectionElementBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of projection elements." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcProjectionElement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Area_3oeSf80G93jhm$lrcvCmdP" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Volume_0v4MMyo9v59fK0AkoEQN9i" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="215aG77EHErgeAFMg$paZa" Name="Qto_ProtectiveDeviceBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of protective device." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcProtectiveDevice">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_2wzjQxh5H7ZALNoJoJWAwE" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3lG2IIOpz1PuQ$te8ZnGuh" Name="Qto_ProtectiveDeviceTrippingUnitBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of protective device tripping unit." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcProtectiveDeviceTrippingUnit">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_01dCdA2zL9Sf_o9HgyD5uh" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2UGS3R5YzF7hstsWDTwD0X" Name="Qto_PumpBaseQuantities" Description="Base quantities that are common to the definition of all types of pumps." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcPump">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_0vSG9GRDbD5AbNcFYXHyw5" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2HxTDcFDb51RJIM0ZznDDR" Name="Qto_RailBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of rail." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcRail">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Length_12VlqG8sb7DQA2dQlUV7OR" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Volume_3Mf9e7UD5EZOIc4EQbT0xv" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Weight_2ueoe8QyrBduWuJHsi21zb" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1Fh58OFtTD3fz8LEdf4$TK" Name="Qto_RailingBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of railings." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcRailing">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Length_25Uys$MQb2a8qWjqTa2SG7" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0rlWCYbyH02RREPFxBxj2G" Name="Qto_RampFlightBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of ramp flights." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcRampFlight">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Length_0mnhKv2352bP05kAyx9dZS" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Width_2c$HEWc1b0ixiL$_rMctwP" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossArea_2E$UHt0Ij2bhNKlWZRgc6b" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetArea_1Cm3Wf9gz6Pv9Yf5jcGsIz" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossVolume_1jjfV2W558hg0ihu$no3sS" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetVolume_3wYY9NR8r4IOia2k0qQWJm" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3K$8Shz$bExuadtgCVu64H" Name="Qto_ReinforcedSoilBaseQuantities" Description="Quantity sets for Reinforced Soil Base." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcReinforcedSoil">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Length_12VlqG8sb7DQA2dQlUV7OR" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Width_2vkF8AsQL5fg4keqWbdE8G" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Depth_1EfY1EUxjCYfMfDim4N8cC" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Area_1CnNsFYBT6$AemE3IaDxL7" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Volume_3Mf9e7UD5EZOIc4EQbT0xv" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1yBk2ygZz9TxxfkC_gyWZV" Name="Qto_ReinforcingElementBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of reinforcement." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcReinforcingElement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Count_3CXRmexyLE4xZy3hpRnxmb" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Length_1E2FefAfrAtvyN5FmHjQ95" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Weight_2ueoe8QyrBduWuJHsi21zb" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="18$_auxt9FoeYNlFbaW7W1" Name="Qto_RoofBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of roof." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcRoof">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossArea_3V2OMyAGXDUOZ$12fLJgCr" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetArea_1ByOtKo4rDs8RprEsr6YLM" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="ProjectedArea_3fuF$itwL6PfQEQsct7uhL" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0GH8HxWALBChtoyBC_GLmL" Name="Qto_SanitaryTerminalBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of sanitary terminal." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcSanitaryTerminal">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_0ZKKf9O7rAOurEWxXgLOOy" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3tBqsS39T6WOBVevU7vLyE" Name="Qto_SensorBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of sensor." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcSensor">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_0mov4erQL9RPHiBBypmvPU" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2mB9s7Wrn3kxxRUqfb0J1W" Name="Qto_SignalBaseQuantities" Description="Base quantities for Signals." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcSignal">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Weight_2ueoe8QyrBduWuJHsi21zb" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3xI5xed7v6ofqFwiNVrwf1" Name="Qto_SignBaseQuantities" Description="" TemplateType="qto_occurrencedriven" ApplicableEntity="IfcSign">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Height_3jq0d8r0zBYvccpej6okcm" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Width_2vkF8AsQL5fg4keqWbdE8G" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Thickness_29hrivl4D9Xv3Ij$kS6FDr" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Weight_2ueoe8QyrBduWuJHsi21zb" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2XFSM7AIT5IuEqiUOxxKSN" Name="Qto_SiteBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of site." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcSite">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossPerimeter_3kV1CSxXX7280RBRNjvyoq" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossArea_3AlAzdg6P3kOXDDJ48Kvdy" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3GbrjZQZ52SvxC6z0bkaIn" Name="Qto_SlabBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of slabs." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcSlab">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Width_030qr7WMT5MBD4pdKmjYUh" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Length_3khYIfZeD0OuKusADQQdov" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Depth_1EfY1EUxjCYfMfDim4N8cC" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Perimeter_1sFKpDR$14zwRXxmfeKbrO" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossArea_2xt4x2$lzD8wZCrac3MEZ0" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetArea_29izq2o8PDM9ZgFTCAF4ra" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossVolume_14RqdfQXT4qQ82_ZE93nfB" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetVolume_0VFGaSH455JRzx81I_y2ka" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_28SdjVtSj3qQ3gvIiqeUIa" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetWeight_3pzRYkes59nwqFKndMTa2o" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2Nt8bpxQP6C89ypP0N1JXz" Name="Qto_SleeperBaseQuantities" Description="Base quantities common to the definition to all occurrences of IfcTrackElement with PredefinedType set to SLEEPER." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcTrackElement/SLEEPER">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Length_12VlqG8sb7DQA2dQlUV7OR" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Width_2vkF8AsQL5fg4keqWbdE8G" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Height_3jq0d8r0zBYvccpej6okcm" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1LzS9Roa10huySHnFwUpir" Name="Qto_SolarDeviceBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of solar devices." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcSolarDevice">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_0GI$hJlcr1_OvDjxkjhZz8" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossArea_07WxT01B12WP6OkgfBTD0k" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0dotH3YWr6wxkB0Ca9kGaS" Name="Qto_SpaceBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of spaces." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcSpace">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Height_3XxoA_x39CYBTbBTI6Ucc_" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FinishCeilingHeight_1vYXYSNGLCGBg4RxwFeBW6" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="FinishFloorHeight_2O2lcrTij5CvLysWdIXQ2z" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossPerimeter_0GKCFgoO9ArwXCKMOoo8xB" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetPerimeter_1iifDS_eX5VQSApD679O_R" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossFloorArea_3fve5N$vz0P8eIQjIdXbUs" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetFloorArea_2L2PpHBjL5yR$QAv1NUTbm" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWallArea_0Rz99oZ4vFMQhYwpYjPCL_" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetWallArea_1CjLoCIRL1gA$0S8yIZq2r" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossCeilingArea_0l3_qgbX13XAuy5XMUIgXf" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetCeilingArea_3yUyI6Y6r4gukTxM5fD3Dd" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossVolume_27rr6u2MD8fw7H8mqNEcYU" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetVolume_05GG55xZz039SwUeIyPkET" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2i$81OljD5vAb0uWrm3Lmo" Name="Qto_SpaceHeaterBaseQuantities" Description="Base quantities that are common to the definition of all types of space heaters." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcSpaceHeater">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Length_2pjqbPAJ1C4BfN5MpqR$55" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_0BJRbPAbfDivUkRgI7mLpw" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetWeight_1IERUjvLP3pxK5DJNuud5g" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0nkoz0n2j4txKAhmRmZx9r" Name="Qto_SpatialZoneBaseQuantities" Description="Base quantities set for Spatial Zones." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcSpatialZone">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Length_12VlqG8sb7DQA2dQlUV7OR" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Width_2vkF8AsQL5fg4keqWbdE8G" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Height_3jq0d8r0zBYvccpej6okcm" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0q5Wgd_pH0MBOccVizT_Wb" Name="Qto_StackTerminalBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of stack terminal." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcStackTerminal">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_3WAQZKjvb4QQKwL_93u9EK" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2BwuvS1U1EaPJectlvV02T" Name="Qto_StairFlightBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of stair flights." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcStairFlight">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Length_2kNfSScs5BTAVyaOQHdEQQ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossVolume_14nohS8fbDaRUpazUdVSy5" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetVolume_22Y7WG9CXC9uU51QkMI8w7" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0EH8mjFNDCphBKvTdjspxM" Name="Qto_SurfaceFeatureBaseQuantities" Description="Base quantities for Surface Features." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcSurfaceFeature">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Area_1CnNsFYBT6$AemE3IaDxL7" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Length_12VlqG8sb7DQA2dQlUV7OR" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3ATtFC43f9g9aVazC5KgMY" Name="Qto_SwitchingDeviceBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of switching device." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcSwitchingDevice">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_2d69Q1SRP8v8rWzJ07$Kdd" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0P6HdwQWHF_wpn21kw$chx" Name="Qto_TankBaseQuantities" Description="Base quantities that are common to the definition of all types of tanks." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcTank">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_2D$gyRToX6ifRSHPJIOPCo" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetWeight_0po45W9AL0j869JY4q3gta" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="TotalSurfaceArea_09I0_N2T97QeOrJ9qSxfeT" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2K3RySdCT4UBtNdzp5BEbt" Name="Qto_TransformerBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of transformer." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcTransformer">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_0uKYqWzxn8nwtXEyQJTMaw" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2fErxFXtXE$PukN498IZD_" Name="Qto_TubeBundleBaseQuantities" Description="Base quantities that are common to the definition of all types of tube bundles." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcTubeBundle">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_05375LeRf2auX0OD69UDJ$" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetWeight_17br2$zor1LeqOt68gddkK" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2JyNQXU5v3aBJzysmo7mot" Name="Qto_UnitaryControlElementBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of unitary control element." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcUnitaryControlElement">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_3vrK_zBzz6xQncWDay9ia9" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2IpsU5W811eBiDUToWdHPZ" Name="Qto_UnitaryEquipmentBaseQuantities" Description="Base quantities that are common to the definition of all types of unitary equipment." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcUnitaryEquipment">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_0m9HvtmSbD2Q2B3reqlYyB" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="18OaPa7X12XfaeJ6gEay5i" Name="Qto_ValveBaseQuantities" Description="Base quantities that are common to the definition of all types of valves." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcValve">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_0x6znX0LLALQF8nzpFwsoX" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3zvysmN8b3dRlmZ0vWS086" Name="Qto_VehicleBaseQuantities" Description="Quantities for vehicles" TemplateType="qto_occurrencedriven" ApplicableEntity="IfcVehicle/ROLLINGSTOCK,IfcVehicle/VEHICLEAIR,IfcVehicle/VEHICLEMARINE,IfcVehicle/VEHICLETRACKED,IfcVehicle/VEHICLE">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Length_12VlqG8sb7DQA2dQlUV7OR" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Width_2vkF8AsQL5fg4keqWbdE8G" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Height_3jq0d8r0zBYvccpej6okcm" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1MUsd$xgn6$Azw0ws0S3QX" Name="Qto_VibrationIsolatorBaseQuantities" Description="Base quantities that are common to the definition of all types of vibration isolators." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcVibrationIsolator">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_2wYRWuU9n6FwcgXHQuQT1Z" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="0yBOOdpVXDS9qQEv_kTjZb" Name="Qto_VolumetricStratumBaseQuantities" Description="Quantity measures associated to volumetric stratum such as in a geotechnical model. Uncertainty is documented in _Pset_Uncertainty_." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcGeotechnicalStratum">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Area_1WROcqqYjDCOj4JQqqzQwC" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Mass_1RL9YZzxfF8OOLIYHIynpF" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="PlanArea_19SFEqi01B3ALdNGRte$7C" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Volume_2SpRPw_wHB28DYepaP_sPV" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="2RAPiCqAX4jgXLCSyvEp5c" Name="Qto_WallBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of walls." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcWall">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Length_0tSm_oibzF$hmgsUBZDeIH" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Width_2ekc6Lw$vDfB57nG1Sm4wB" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Height_3WbJ7i_U9ArhOXaHfEfvFa" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossFootPrintArea_0P10Tj2OL2Wv_h8X9BES4K" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetFootPrintArea_08AeXBr_1BtfH8IkgbSECv" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossSideArea_3T7_AKruz0TBm3ToQt0Naj" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetSideArea_3dROH$uFj4vPNKtWkhmkoW" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossVolume_33_HQffm1D28GEII3cbBRn" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetVolume_0WOBpKa3L63h9k7gjdhvMQ" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_0WGCvpd9TC1hpTeTokrgzm" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="NetWeight_32ZfEUaFj1$8OmykwIZY3k" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="3QuLJTjTP1ggk3hFhLY5sZ" Name="Qto_WasteTerminalBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of waste terminal." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcWasteTerminal">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="GrossWeight_2kZNH8VxTCIQ$55loAyOr6" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
				<IfcPropertySetTemplate GlobalId="1Kq1ZLuvbABfkiE3GFe6hP" Name="Qto_WindowBaseQuantities" Description="Base quantities that are common to the definition of all occurrences of windows." TemplateType="qto_occurrencedriven" ApplicableEntity="IfcWindow">
					<HasPropertyTemplates>
						<IfcSimplePropertyTemplate xsi:nil="true" href="Width_18UcPG7iP4zfJktZU_maoy" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Height_1hGPoGg2L09v1afkqhXBHH" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Perimeter_0vtU$HxUn5fR2RNi$2nSSt" />
						<IfcSimplePropertyTemplate xsi:nil="true" href="Area_0ghx$p4BP9bPO6p1adKSEF" />
					</HasPropertyTemplates>
				</IfcPropertySetTemplate>
			</RelatedDefinitions>
		</IfcRelDeclares>
	</IfcProjectLibrary>
</ifcXML>
