<?xml version="1.0" encoding="utf-8"?>
<PropertySetDef xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xsd="http://www.w3.org/2001/XMLSchema" ifdguid="05465994845944b18e128851e6c6ea7e" templatetype="PSET_TYPEDRIVENOVERRIDE" xsi:noNamespaceSchemaLocation="http://buildingSMART-tech.org/xml/psd/PSD_IFC4.xsd">
  <IfcVersion version="IFC4X4" />
  <Name>Pset_TicketProcessing</Name>
  <Definition>Properties for indicating performance ratings for ticket processing of entry elements (e.g. turnstile, boom barrier).</Definition>
  <Applicability />
  <ApplicableClasses>
    <ClassName>IfcDoor/TURNSTILE</ClassName>
    <ClassName>IfcDoor/BOOM_BARRIER</ClassName>
  </ApplicableClasses>
  <ApplicableTypeValue>IfcDoor/TURNSTILE,IfcDoor/BOOM_BARRIER</ApplicableTypeValue>
  <PropertyDefs>
    <PropertyDef ifdguid="47589326faef4804836980a1108d374a">
      <Name>TicketProcessingTime</Name>
      <Definition>Indicates the processing time of a ticket.</Definition>
      <PropertyType>
        <TypePropertySingleValue>
          <DataType type="IfcTimeMeasure" />
        </TypePropertySingleValue>
      </PropertyType>
      <NameAliases />
      <DefinitionAliases />
    </PropertyDef>
    <PropertyDef ifdguid="fcd5a049b4384ce1b009b6667ed9e694">
      <Name>TicketStuckRatio</Name>
      <Definition>Indicates the ratio of tickets being stuck or jammed in the appliance.</Definition>
      <PropertyType>
        <TypePropertySingleValue>
          <DataType type="IfcRatioMeasure" />
        </TypePropertySingleValue>
      </PropertyType>
      <NameAliases />
      <DefinitionAliases />
    </PropertyDef>
  </PropertyDefs>
  <PsetDefinitionAliases />
</PropertySetDef>