7.4.4.40 Pset_LightFixtureTypeCommon

PSET_TYPEDRIVENOVERRIDE / IfcLightFixture

Light Fixture Type CommonCommon data for light fixtures. History: IFC4 - Article number and manufacturer specific information deleted. Use Pset_ManufacturerTypeInformation. ArticleNumber instead. Load properties moved from Pset_LightFixtureTypeThermal (deleted).
照明器具の共通データ。 IFC4でArticleNumberは削除されました。代わりにPset_ManufacturerTypeInformationを使用してください。
Properties

PSD-XML

NameTypeDescription
Reference P_SINGLEVALUE / IfcIdentifier
ReferenceReference ID for this specified type in this project (e.g. type 'A-1'), Also referred to as "construction type". It should be provided as an alternative to the name of the "object type", if the software does not support object types and no classification reference to a recognized classification system used.
IFC4.3.0.0 DEPRECATION  The Reference property is deprecated and shall no longer be used, use attribute Name on the relating type instead.
参照当該プロジェクトで定義する形式の参照ID(例:A-1)、承認された分類に存在しないときに使用される。
Status P_ENUMERATEDVALUE / IfcLabel / PEnum_ElementStatus
StatusStatus of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as "New" - element designed as new addition, "Existing" - element exists and remains, "Demolish" - element existed but is to be demolished, "Temporary" - element will exists only temporary (like a temporary support structure).
状態要素(主にリノベーションまたは改修プロジェクトにおいて)の状態。 状態は、「新規(New)」-新しく追加される要素。「既存」-要素は存在し、かつ残りもの。「破壊」-要素は存在したが、廃棄されるもの。「一時的」-一時的に存在する要素(一時的にサポートしている構造のようなもの)。
NumberOfSources P_SINGLEVALUE / IfcCountMeasure
Number Of SourcesNumber of sources .
電球数電球数。
TotalWattage P_SINGLEVALUE / IfcPowerMeasure
Total WattageWattage on whole lightfitting device with all sources intact.
総ワット数全ての照明器具のワット数。
LightFixtureMountingType P_ENUMERATEDVALUE / IfcLabel / PEnum_LightFixtureMountingType
Light Fixture Mounting TypeA list of the available types of mounting for light fixtures from which that required may be selected.
照明器具取付方法照明器具の取付方法をリストから選択。
LightFixturePlacingType P_ENUMERATEDVALUE / IfcLabel / PEnum_LightFixturePlacingType
Light Fixture Placing TypeA list of the available types of placing specification for light fixtures from which that required may be selected.
照明器具取付場所照明器具の取付場所をリストから選択。
MaintenanceFactor P_SINGLEVALUE / IfcReal
Maintenance FactorThe arithmetical allowance made for depreciation of lamps and reflective equipment from their initial values due to dirt, fumes, or age.
保守率汚れ、煙、年数による初期からのランプや反射装置の低減許容計算。
MaximumPlenumSensibleLoad P_SINGLEVALUE / IfcPowerMeasure
Maximum Plenum Sensible LoadMaximum or Peak sensible thermal load contributed to return air plenum by the light fixture.
MaximumSpaceSensibleLoad P_SINGLEVALUE / IfcPowerMeasure
Maximum Space Sensible LoadMaximum or Peak sensible thermal load contributed to the conditioned space by the light fixture.
SensibleLoadToRadiant P_SINGLEVALUE / IfcPositiveRatioMeasure
Sensible Load To RadiantPercent of sensible thermal load to radiant heat.