7.4.4.43 Pset_OutletTypeCommon

PSET_TYPEDRIVENOVERRIDE / IfcOutlet

Outlet Type CommonCommon properties for different outlet types.
異なる差込口タイプの共通プロパティ。
Properties

PSD-XML

NameTypeDescription
Reference P_SINGLEVALUE / IfcIdentifier
ReferenceReference ID for this specified type in this project (e.g. type 'A-1'), Also referred to as "construction type". It should be provided as an alternative to the name of the "object type", if the software does not support object types and no classification reference to a recognized classification system used.
IFC4.3.0.0 DEPRECATION  The Reference property is deprecated and shall no longer be used, use attribute Name on the relating type instead.
参照当該プロジェクトで定義する形式の参照ID(例:A-1)、承認された分類に存在しないときに使用される。
Status P_ENUMERATEDVALUE / IfcLabel / PEnum_ElementStatus
StatusStatus of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as "New" - element designed as new addition, "Existing" - element exists and remains, "Demolish" - element existed but is to be demolished, "Temporary" - element will exists only temporary (like a temporary support structure).
状態要素(主にリノベーションまたは改修プロジェクトにおいて)の状態。 状態は、「新規(New)」-新しく追加される要素。「既存」-要素は存在し、かつ残りもの。「破壊」-要素は存在したが、廃棄されるもの。「一時的」-一時的に存在する要素(一時的にサポートしている構造のようなもの)。
IsPluggableOutlet P_SINGLEVALUE / IfcLogical
Is Pluggable OutletIndication of whether the outlet accepts a loose plug connection (= TRUE) or whether it is directly connected (= FALSE) or whether the form of connection has not yet been determined (= UNKNOWN).
プラグ接続可否差込口が緩いプラグ接続を認めるか、それが直接接続されるかどうか、あるいは接続の形式がまだ決定されていないかを指示する。
NumberOfSockets P_SINGLEVALUE / IfcCountMeasure
Number Of SocketsThe number of sockets that may be connected. In case of inconsistency, sockets defined on ports take precedence.

Link to this page  Link to this page