7.6.4.6 Pset_InterceptorTypeCommon

PSET_TYPEDRIVENOVERRIDE / IfcInterceptor

Interceptor Type CommonCommon properties for interceptors.
阻集器の共通プロパティを設定します。
Properties

PSD-XML

NameTypeDescription
Reference P_SINGLEVALUE / IfcIdentifier
ReferenceReference ID for this specified type in this project (e.g. type 'A-1'), Also referred to as "construction type". It should be provided as an alternative to the name of the "object type", if the software does not support object types and no classification reference to a recognized classification system used.
IFC4.3.0.0 DEPRECATION  The Reference property is deprecated and shall no longer be used, use attribute Name on the relating type instead.
参照当該プロジェクトで定義する形式の参照ID(例:A-1)、承認された分類に存在しないときに使用される。
Status P_ENUMERATEDVALUE / IfcLabel / PEnum_ElementStatus
StatusStatus of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as "New" - element designed as new addition, "Existing" - element exists and remains, "Demolish" - element existed but is to be demolished, "Temporary" - element will exists only temporary (like a temporary support structure).
状態要素(主にリノベーションまたは改修プロジェクトにおいて)の状態。 状態は、「新規(New)」-新しく追加される要素。「既存」-要素は存在し、かつ残りもの。「破壊」-要素は存在したが、廃棄されるもの。「一時的」-一時的に存在する要素(一時的にサポートしている構造のようなもの)。
NominalBodyLength P_SINGLEVALUE / IfcPositiveLengthMeasure
Nominal Body LengthNominal or quoted length measured along the x-axis of the local coordinate system of the object.
NominalBodyWidth P_SINGLEVALUE / IfcPositiveLengthMeasure
Nominal Body WidthNominal or quoted length, measured along the y-axis of the local coordinate system of the object.
NominalBodyDepth P_SINGLEVALUE / IfcPositiveLengthMeasure
Nominal Body DepthNominal or quoted length measured along the z-axis of the local coordinate system of the object.
InletConnectionSize P_SINGLEVALUE / IfcPositiveLengthMeasure
Inlet Connection SizeSize of the inlet connection. Note that all inlet connections are assumed to be the same size.
OutletConnectionSize P_SINGLEVALUE / IfcPositiveLengthMeasure
Outlet Connection SizeSize of the outlet connection from the object.
CoverLength P_SINGLEVALUE / IfcPositiveLengthMeasure
Cover LengthThe length measured along the x-axis in the local coordinate system or the radius (in the case of a circular shape in plan) of the cover of the object.
CoverWidth P_SINGLEVALUE / IfcPositiveLengthMeasure
Cover WidthThe length measured along the y-axis in the local coordinate system of the cover of the object.
VentilatingPipeSize P_SINGLEVALUE / IfcPositiveLengthMeasure
Ventilating Pipe SizeSize of the ventilating pipe(s).

Link to this page  Link to this page