7.8.4.112 Pset_RailwayBalise

PSET_TYPEDRIVENOVERRIDE / IfcCommunicationsAppliance / TRANSPONDER

Properties applicable to a railway balise. This property set is applied to a type or occurrence of IfcCommunicationsAppliance with predefined type TRANSPONDER.
Properties

PSD-XML

NameTypeDescription
NominalHeight P_SINGLEVALUE / IfcNonNegativeLengthMeasure The nominal height of the object. The size information is provided in addition to the shape representation and the geometric parameters used within. In cases of inconsistency between the geometric parameters and the size properties, provided in the attached property set, the geometric parameters take precedence.
NominalWidth P_SINGLEVALUE / IfcNonNegativeLengthMeasure
Nominal WidthThe nominal overall width of the object. The size information is provided in addition to the shape representation and the geometric parameters used within. In cases of inconsistency between the geometric parameters and the size properties, provided in the attached property set, the geometric parameters take precedence.
公称幅呼び幅寸法。
NominalWeight P_SINGLEVALUE / IfcMassMeasure Nominal weight of the object.
NominalLength P_SINGLEVALUE / IfcNonNegativeLengthMeasure
Nominal LengthThe nominal overall length of the object. The size information is provided in addition to the shape representation and the geometric parameters used within. In case of inconsistency between the geometric parameters and the size properties, provided in the attached property set, the geometric parameters take precedence.
FailureInformation P_SINGLEVALUE / IfcText The information for failure description.
RailwayBaliseType P_ENUMERATEDVALUE / IfcLabel / PEnum_RailwayBaliseType Type of the railway balise.
DetectionRange P_SINGLEVALUE / IfcPositiveLengthMeasure The detection range of the equipment.
InformationLength P_SINGLEVALUE / IfcInteger Indicates supported bytes of the data Information, e.g.127 bytes.
TransmissionRate P_SINGLEVALUE / IfcIntegerCountRateMeasure Data transmission rate between the device and the receiving module in bits per second.
OperationalTemperatureRange P_BOUNDEDVALUE / IfcThermodynamicTemperatureMeasure
Operational Temperature RangeThe temperature range in which the device operates normally. Allowable operation ambient air temperature range.
PlageTempératureOpérationelleOpération admise sur la plage de température de l'air ambiant
動作温度範囲動作を許容する周囲温度の範囲
IP_Code P_SINGLEVALUE / IfcLabel
IP_ CodeIP Code, the International Protection Marking, IEC 60529), classifies and rates the degree of protection provided against intrusion.

Link to this page  Link to this page