7.8.4.142 Pset_TractionPowerSystem

PSET_OCCURRENCEDRIVEN / IfcDistributionSystem / ELECTRICAL

Properties of a traction power system. The property is associated to the predefined type ELECTRICAL of IfcDistributionSystem, and is used to characterise systems such as railway electrical distribution networks used to provide energy for rolling stock.
Properties

PSD-XML

NameTypeDescription
PowerSupplyMode P_ENUMERATEDVALUE / IfcLabel / PEnum_PowerSupplyMode Power supply mode of the equipment or system.
ElectrificationType P_ENUMERATEDVALUE / IfcLabel / PEnum_ElectrificationType Indicates the type of railway electrification.
RatedFrequency P_SINGLEVALUE / IfcFrequencyMeasure Frequency of the AC electric power supply when the device or system reaches its optimum operating condition.
NominalVoltage P_SINGLEVALUE / IfcElectricVoltageMeasure The optimum voltage for the electrical appliance or system.

Link to this page  Link to this page