Name | Type | Description |
Reference |
P_SINGLEVALUE
/
IfcIdentifier
|
| Reference | Reference ID for this specified type in this project (e.g. type 'A-1'), Also referred to as "construction type". It should be provided as an alternative to the name of the "object type", if the software does not support object types and no classification reference to a recognized classification system used.
IFC4.3.0.0 DEPRECATION The Reference property is deprecated and shall no longer be used, use attribute Name on the relating type instead.
|
| 参照 | 当該プロジェクトで定義する形式の参照ID(例:A-1)、承認された分類に存在しないときに使用される。
|
|
Status |
P_ENUMERATEDVALUE
/
IfcLabel
/
PEnum_ElementStatus |
| Status | Status of the element, predominately used in renovation or retrofitting projects. The status can be assigned to as "New" - element designed as new addition, "Existing" - element exists and remains, "Demolish" - element existed but is to be demolished, "Temporary" - element will exists only temporary (like a temporary support structure).
|
| Etat | Etat de l'élément, utilisé avant tout pour les projets de rénovation et réaménagement. L'état assigné peut être "Nouveau" - l'élément prévu pour du neuf, "Existant" - l'élément existait et est maintenu, "Démoli" - l'élément existait mais doit être démoli/supprimé, "Provisoire" - l'élément existera à titre provisoire seulement (comme un support structurel par exemple).
|
| 状態 | 要素(主にリノベーションまたは改修プロジェクトにおいて)の状態。 状態は、「新規(New)」-新しく追加される要素。「既存」-要素は存在し、かつ残りもの。「破壊」-要素は存在したが、廃棄されるもの。「一時的」-一時的に存在する要素(一時的にサポートしている構造のようなもの)。
|
|
HeatTransferTypeEnum |
P_ENUMERATEDVALUE
/
IfcLabel
/
PEnum_AirToAirHeatTransferHeatTransferType |
| Heat Transfer Type Enum | Type of heat transfer between the two air streams.
|
| TypeEchangeChaleurEnum | Type de transfert de chaleur entre deux flux d'air.
|
| 熱交換種類 | 空気間の熱交換の種類(顕熱、潜熱…)
|
|
HasDefrost |
P_SINGLEVALUE
/
IfcBoolean
|
| Has Defrost | has the heat exchanger has defrost function or not.
|
| PossèdeDégel | Possède ou non une fonction dégel sur l'échangeur de chaleur
|
| デフロスト有無 | 熱交換器のデフロスト機能有無
|
|
OperationalTemperatureRange |
P_BOUNDEDVALUE
/
IfcThermodynamicTemperatureMeasure
|
| Operational Temperature Range | The temperature range in which the device operates normally.
Allowable operation ambient air temperature range.
|
| PlageTempératureOpérationelle | Opération admise sur la plage de température de l'air ambiant
|
| 動作温度範囲 | 動作を許容する周囲温度の範囲
|
|
PrimaryAirFlowRateRange |
P_BOUNDEDVALUE
/
IfcVolumetricFlowRateMeasure
|
| Primary Airflow Rate Range | Possible range of primary airflow that can be delivered.
|
| PlageDébitAirPrimaire | Plage possible de débit d'air au primaire qui peut être fourni.
|
| 一次側風量範囲 | 一次側の送風可能範囲
|
|
SecondaryAirFlowRateRange |
P_BOUNDEDVALUE
/
IfcPressureMeasure
|
| Secondary Airflow Rate Range | possible range of secondary airflow that can be delivered.
|
| PlageDébitAirSecondaire | Plage possible de débit d'air au secondaire qui peut être fourni.
|
| 二次側風量範囲 | 二次側の送風可能範囲
|
|