| Name | Type | Description |
| EarlyStrengthDevelopment |
P_ENUMERATEDVALUE
/
IfcLabel
/
PEnum_EarlyStrengthDevelopment |
Class of energy absorption according to EN 14487-1
This is strongly dependent on the place of application of the sprayed concrete or mortar where different requirements for early strength development must be met
|
| FibreType |
P_ENUMERATEDVALUE
/
IfcLabel
/
PEnum_SprayedConcreteFibreType |
The type of fibre used to reinforce the sprayed concrete.
|
| FibreVolumeRatio |
P_SINGLEVALUE
/
IfcMassDensityMeasure
|
Quantity of fibres per cubic meter of shotcrete.
|
| FibreLength |
P_SINGLEVALUE
/
IfcPositiveLengthMeasure
|
Length of the fibre.
|
| FibreDiameter |
P_SINGLEVALUE
/
IfcPositiveLengthMeasure
|
Diameter of the fibre.
|
| AspectRatio |
P_SINGLEVALUE
/
IfcPositiveRatioMeasure
|
Length/Diameter of fibre.
|
| ResidualTensileStrengthfR1k |
P_SINGLEVALUE
/
IfcPressureMeasure
|
fR1k to fib Model Code 2010, fibre reinforced concrete.
|
| ResidualTensileStrengthfR3k |
P_SINGLEVALUE
/
IfcPressureMeasure
|
fR3k to fib Model Code 2010, fibre reinforced concrete.
|
| ResidualTensileStrengthfLk |
P_SINGLEVALUE
/
IfcPressureMeasure
|
fLk to fib Model Code 2010, fibre reinforced concrete.
|
| ResidualStrengthStructualClass |
P_ENUMERATEDVALUE
/
IfcLabel
/
PEnum_ResidualStrengthStructuralClass |
Residual Strength Ratio to fib Model Code 2010, fibre reinforced concrete.
|
| CompressiveStrength24h |
P_SINGLEVALUE
/
IfcPressureMeasure
|
Compressive strength of the concrete at 24h.
|
| CompressiveStrength48h |
P_SINGLEVALUE
/
IfcPressureMeasure
|
Compressive strength of the concrete at 48h.
|
| EnergyAbsportionCapacity7d |
P_SINGLEVALUE
/
IfcEnergyMeasure
|
Energy absorption capacity after 7 days according EN 14488-5 standard (only for fibre concrete).
|
| EnergyAbsportionCapacity28d |
P_SINGLEVALUE
/
IfcEnergyMeasure
|
Energy absorption capacity after 28 days according EN 14488-5 standard (only for fibre concrete).
|